LUM-OCM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF DisplayString, DateAndTime FROM SNMPv2-TC lumModules, lumOcmMIB FROM LUM-REG FaultStatus, MgmtNameString, SubrackNumber, SlotNumber, PortNumber, LambdaFrequency, BoardOrInterfaceOperStatus, BoardOrInterfaceAdminStatus, CommandString FROM LUM-TC; lumOcmMIBModule MODULE-IDENTITY LAST-UPDATED "201806150000Z" -- June 15th 2018 ORGANIZATION "Infinera Corporation" CONTACT-INFO "techsupport@infinera.com" DESCRIPTION "The optical control interface MIB. - General - Monitor interfaces Note that, every time a get operation is performed and both ports are set to admin status up, the switch will switch to update both ports. (unless commissioning mode) The guaranteed durability of switching is 10 million times. That means, if you switch (perform a get operation) more than every 50 second, product lifetime of 15 years can not be guaranteed. " REVISION "201806150000Z" -- June 15th 2018 DESCRIPTION " Changes made for release r31.0: - Added ocmIfSpacingMode and ocmIfHighInputPower in ocmIfEntry." REVISION "201712150000Z" -- Dec 15th 2017 DESCRIPTION " Changes made for release r30.0: - Added ocmChannelReferenceTime and ocmChannelSaveReference action in ocmChannel." REVISION "201706150000Z" -- June 15th 2017 DESCRIPTION "Changes made for release r29.0: - Changed ORGANIZATION and CONTACT-INFO" REVISION "201601110000Z" -- Jan 11th 2016 DESCRIPTION "Added default value notPresent for operStatus." REVISION "201405160000Z" -- May 16th 2014 DESCRIPTION "Added a parameter for offset adjustment which will allow for better regulation in the optical control loop" REVISION "200801160000Z" -- January 16th 2008 DESCRIPTION "First version." ::= { lumModules 33 } -- ---------------------------------------------------- -- Conformance area, containing groups and complicance -- specifications. -- ---------------------------------------------------- lumOcmConfs OBJECT IDENTIFIER ::= { lumOcmMIB 1 } lumOcmGroups OBJECT IDENTIFIER ::= { lumOcmConfs 1 } lumOcmCompl OBJECT IDENTIFIER ::= { lumOcmConfs 2 } lumOcmMinimalGroups OBJECT IDENTIFIER ::= { lumOcmConfs 3 } lumOcmMinimalCompl OBJECT IDENTIFIER ::= { lumOcmConfs 4 } -- ---------------------------------------------------- -- Root for objects in the ocm MIB -- ---------------------------------------------------- lumOcmMIBObjects OBJECT IDENTIFIER ::= { lumOcmMIB 2 } -- ---------------------------------------------------- -- This MIB contains the following groups: -- ---------------------------------------------------- ocmGeneral OBJECT IDENTIFIER ::= { lumOcmMIBObjects 1 } ocmIfList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 2 } ocmChannelList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 3 } lumentisOcmNotifications OBJECT IDENTIFIER ::= { lumOcmMIBObjects 4 } -- ---------------------------------------------------- -- Textual Conventions -- ---------------------------------------------------- -- ---------------------------------------------------- -- General group -- ---------------------------------------------------- ocmGeneralLastChangeTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time when the configuration of the MIB was last changed. " ::= { ocmGeneral 1 } ocmGeneralStateLastChangeTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time when the state of the MIB was last changed. " ::= { ocmGeneral 2 } ocmGeneralOcmIfTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Size of table " ::= { ocmGeneral 3 } ocmGeneralOcmChannelTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Size of table " ::= { ocmGeneral 4 } -- ---------------------------------------------------- -- Optical control interfaces -- ---------------------------------------------------- ocmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF OcmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface list." ::= { ocmIfList 1 } ocmIfEntry OBJECT-TYPE SYNTAX OcmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the interface list. " INDEX { ocmIfIndex } ::= { ocmIfTable 1 } OcmIfEntry ::= SEQUENCE { ocmIfIndex Unsigned32, ocmIfName MgmtNameString, ocmIfDescr DisplayString, ocmIfSubrack SubrackNumber, ocmIfSlot SlotNumber, ocmIfRxPort PortNumber, ocmIfInvPhysIndexOrZero Unsigned32, ocmIfAdminStatus BoardOrInterfaceAdminStatus, ocmIfOperStatus BoardOrInterfaceOperStatus, ocmIfPowerThreshold Integer32, ocmIfPowerOffset Integer32, ocmIfMaxPowerLevel Integer32, ocmIfMinPowerLevel Integer32, ocmIfDeltaPower Integer32, ocmIfConnectedBoardType INTEGER, ocmIfUpdateLastChangeTime DateAndTime, ocmIfConnectedSubrack SubrackNumber, ocmIfConnectedSlot SlotNumber, ocmIfConnectedPort PortNumber, ocmIfActivePort PortNumber, ocmIfControlMode INTEGER, ocmIfReferenceTime DisplayString, ocmIfSwitchFailure FaultStatus, ocmIfDataSourceNotDefined FaultStatus, ocmIfCommissioningMode FaultStatus, ocmIfModuleFailure FaultStatus, ocmIfConfigurationCommand CommandString, ocmIfChangeConnectedPort CommandString, ocmIfSaveReference CommandString, ocmIfChangeConnectedBoardType CommandString, ocmIfChangePowerThreshold CommandString, ocmIfChangePowerOffset CommandString, ocmIfPowerOffsetAdjustment Integer32, ocmIfSpacingMode Integer32, ocmIfHighInputPower FaultStatus } ocmIfIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary index assigned to each entry. " ::= { ocmIfEntry 1 } ocmIfName OBJECT-TYPE SYNTAX MgmtNameString MAX-ACCESS read-only STATUS current DESCRIPTION "The management name of the interface, for example 'ocm:1:2:1', where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: ocm:s:s:p - Optical channel module interface " ::= { ocmIfEntry 2 } ocmIfDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User configurable label. " DEFVAL { "" } ::= { ocmIfEntry 3 } ocmIfSubrack OBJECT-TYPE SYNTAX SubrackNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the subrack where the interface is located. " ::= { ocmIfEntry 4 } ocmIfSlot OBJECT-TYPE SYNTAX SlotNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the slot where the interface is located. " ::= { ocmIfEntry 5 } ocmIfRxPort OBJECT-TYPE SYNTAX PortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the port where the RX-side of the interface is located. " ::= { ocmIfEntry 6 } ocmIfInvPhysIndexOrZero OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The row in the invPhysTable for this interface. Set to 0 if not known. " ::= { ocmIfEntry 7 } ocmIfAdminStatus OBJECT-TYPE SYNTAX BoardOrInterfaceAdminStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The interface should be activated when it becomes available. Alarms are not suppressed. " DEFVAL { up } ::= { ocmIfEntry 8 } ocmIfOperStatus OBJECT-TYPE SYNTAX BoardOrInterfaceOperStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state for the interface. notPresent - The physical resources are not available. down - The interface is de-activated or the are faults preventing it from going to the 'up'-state. up - The interface is operational. " DEFVAL { notPresent } ::= { ocmIfEntry 9 } ocmIfPowerThreshold OBJECT-TYPE SYNTAX Integer32 (-50..100) MAX-ACCESS read-create STATUS current DESCRIPTION "The threshold for power levels. If the measured power level is below the threshold, it is regarded as no signal. For OCM8p: Default -13dBm Range -35 to 100dBm For OCM2p: " DEFVAL { -24 } ::= { ocmIfEntry 12 } ocmIfUpdateLastChangeTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time when the last measurement was done. " ::= { ocmIfEntry 13 } ocmIfConnectedSubrack OBJECT-TYPE SYNTAX SubrackNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the subrack where the connected interface is located. (0 is not valid) " DEFVAL { 0 } ::= { ocmIfEntry 14 } ocmIfConnectedSlot OBJECT-TYPE SYNTAX SlotNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the slot where the connected interface is located. (not possible to set 0, 1, 19-22, oa/roadm can not be placed in those slots) " DEFVAL { 0 } ::= { ocmIfEntry 15 } ocmIfConnectedPort OBJECT-TYPE SYNTAX PortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "The number of the connected port. (the tx port number). 1 or 3 for OA, 5 for 1x2ROADM/100G/50G, 9 for 1x4ROADM/100G,ROADM1x4f, 17 for 1x8ROADM/50G, 19 for ROADM1x9f, 1 for OA26C, 5 for OARAED21HG 81 for MDU40. and 1 to 82 for other boards. " DEFVAL { 0 } ::= { ocmIfEntry 16 } ocmIfActivePort OBJECT-TYPE SYNTAX PortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the active port. Only valid when commissioning mode. " DEFVAL { 1 } ::= { ocmIfEntry 17 } ocmIfControlMode OBJECT-TYPE SYNTAX INTEGER { normal (1), commissioning (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chosen as active during commissioning mode. " DEFVAL { normal } ::= { ocmIfEntry 18 } ocmIfReferenceTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Time where reference values were saved. " ::= { ocmIfEntry 21 } ocmIfSwitchFailure OBJECT-TYPE SYNTAX FaultStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Switch failure. A: The switch is stuck and it is not possible to change port. It is not sure if it the values comes from the expected port. D: The switch works as expected. " ::= { ocmIfEntry 22 } ocmIfDataSourceNotDefined OBJECT-TYPE SYNTAX FaultStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Data source not defined, A: No connected slot, connected subrack nor connected port is defined. D: Connected slot, connected subrack and connected port is ok. " ::= { ocmIfEntry 23 } ocmIfCommissioningMode OBJECT-TYPE SYNTAX FaultStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Data source not defined, A: Commissioning mode is used D: Normal mode " ::= { ocmIfEntry 24 } ocmIfModuleFailure OBJECT-TYPE SYNTAX FaultStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The module HW has detected a failure. A: The module has failed D: The module is OK again " ::= { ocmIfEntry 25 } ocmIfConfigurationCommand OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Select which control mode to use. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one port while adjusting surrounding boards. " ::= { ocmIfEntry 26 } ocmIfChangeConnectedPort OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Select which monitor port that is connected to this ocm port. " ::= { ocmIfEntry 27 } ocmIfSaveReference OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Save current measurement as reference values " ::= { ocmIfEntry 28 } ocmIfPowerOffset OBJECT-TYPE SYNTAX Integer32 (0..350) MAX-ACCESS read-create STATUS current DESCRIPTION "An offset value added to all power levels to get an accurate presentation of channel powers at the line port. Generally offset values depends upon board type connected. oa - 20.0 roadm - 17.0 oa26c - 20.0 mdu40 - 20.0 other - 20.0 oaraed21hg - 20.0 oaraed20lg - 20.0 OA boards have more accurate values for power offset named Monitor port insertion loss visible in the OA interface. Note however that the reference power level values are not affected by a change of this offset. A new reference calculation should be made after a change. " ::= { ocmIfEntry 29 } ocmIfConnectedBoardType OBJECT-TYPE SYNTAX INTEGER { oa (1), roadm (2), oa26c (3), mdu40 (4), other (5), oaraed21hg (6), oaraed20lg (7)} MAX-ACCESS read-create STATUS current DESCRIPTION "What board type that is connected to the ocm. The power offset default value is changed based on the chosen board type. Please note that this function is not applicable for mdu40lite boards. " DEFVAL { oa } ::= { ocmIfEntry 30 } ocmIfChangeConnectedBoardType OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Select board type for the monitor port connected to this ocm port. " ::= { ocmIfEntry 31 } ocmIfMaxPowerLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum received power level for this port in units of 0.1 dBm. " ::= { ocmIfEntry 32 } ocmIfMinPowerLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum received power level for this port in units of 0.1 dBm. " ::= { ocmIfEntry 33 } ocmIfDeltaPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The difference between the maximum and the minimum received power level for this port in units of 0.1 dBm. " ::= { ocmIfEntry 34 } ocmIfChangePowerThreshold OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Select the power threshold for this ocm port. If the measured power level is below the threshold, it is regarded as no signal. " ::= { ocmIfEntry 35 } ocmIfChangePowerOffset OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Select the power offset for this ocm port. The power offset is a value added to all power levels to get an accurate presentation of channel powers at the line port. " ::= { ocmIfEntry 36 } ocmIfPowerOffsetAdjustment OBJECT-TYPE SYNTAX Integer32 (0..350) MAX-ACCESS read-only STATUS current DESCRIPTION "An offset adjustment added to the power offset to mitigate the effects of differences between actual power measured at the OCM and the configured power offset value. This adjustment allows the optical control loop to regulate with better precision. " ::= { ocmIfEntry 37 } ocmIfSpacingMode OBJECT-TYPE SYNTAX INTEGER { spacing50GHz (1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Spacing mode is configured for monitoring channel power with the channel spacing of 50GHz. spacing50GHz: interface with channels in 50 GHz intervals " DEFVAL { spacing50GHz } ::= { ocmIfEntry 38 } ocmIfHighInputPower OBJECT-TYPE SYNTAX FaultStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The OCM module has detected a high input power. A: OCM module has dectected high input power (above 20dBm) on particular port. D: Optical input power is within the limit (below 20dBm). " ::= { ocmIfEntry 39 } -- ---------------------------------------------------- -- Optical control channels -- ---------------------------------------------------- ocmChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF OcmChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel list." ::= { ocmChannelList 1 } ocmChannelEntry OBJECT-TYPE SYNTAX OcmChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the channel list. " INDEX { ocmChannelIndex } ::= { ocmChannelTable 1 } OcmChannelEntry ::= SEQUENCE { ocmChannelIndex Unsigned32, ocmChannelName MgmtNameString, ocmChannelFrequency LambdaFrequency, ocmChannelPowerLevel Integer32, ocmChannelUpdateLastChangeTime DateAndTime, ocmChannelOcmRefIfIndex Unsigned32, ocmChannelReferencePowerLevel Integer32, ocmChannelReferenceTime DisplayString, ocmChannelSaveReference CommandString} ocmChannelIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary index assigned to each entry. " ::= { ocmChannelEntry 1 } ocmChannelName OBJECT-TYPE SYNTAX MgmtNameString MAX-ACCESS read-only STATUS current DESCRIPTION "The management name of the interface, for example 'ocm:1:2:1', where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: ocm:s:s:p - Optical channel module interface " ::= { ocmChannelEntry 2 } ocmChannelFrequency OBJECT-TYPE SYNTAX LambdaFrequency MAX-ACCESS read-create STATUS current DESCRIPTION "Freqency in hundreds of GHz (0.01 GHz). " ::= { ocmChannelEntry 3 } ocmChannelPowerLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received power level in units of 0.1 dBm. " ::= { ocmChannelEntry 4 } ocmChannelUpdateLastChangeTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Time when last measurement was done. " ::= { ocmChannelEntry 5 } ocmChannelOcmRefIfIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP-index of the OCM i/f object related to this object. " DEFVAL { 1 } ::= { ocmChannelEntry 6 } ocmChannelReferencePowerLevel OBJECT-TYPE SYNTAX Integer32 (-1000..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "The reference power level in units of 0.1 dBm. " DEFVAL { 1000 } ::= { ocmChannelEntry 7 } ocmChannelReferenceTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Time where reference values were saved. " ::= { ocmChannelEntry 8 } ocmChannelSaveReference OBJECT-TYPE SYNTAX CommandString MAX-ACCESS read-only STATUS current DESCRIPTION "Save current measurement as reference values " ::= { ocmChannelEntry 9 } -- ---------------------------------------------------- -- Notifications -- ---------------------------------------------------- -- n/a -- ---------------------------------------------------- -- Object and event groups -- ---------------------------------------------------- ocmGeneralGroup OBJECT-GROUP OBJECTS { ocmGeneralLastChangeTime, ocmGeneralStateLastChangeTime, ocmGeneralOcmIfTableSize } STATUS current DESCRIPTION "The general objects." ::= { lumOcmGroups 1 } ocmIfGroup OBJECT-GROUP OBJECTS { ocmIfIndex, ocmIfName, ocmIfDescr, ocmIfSubrack, ocmIfSlot, ocmIfRxPort, ocmIfInvPhysIndexOrZero, ocmIfAdminStatus, ocmIfOperStatus, ocmIfPowerThreshold, ocmIfUpdateLastChangeTime, ocmIfConnectedSubrack, ocmIfConnectedSlot, ocmIfConnectedPort, ocmIfActivePort, ocmIfControlMode, ocmIfReferenceTime, ocmIfSwitchFailure, ocmIfDataSourceNotDefined, ocmIfCommissioningMode, ocmIfModuleFailure, ocmIfConfigurationCommand, ocmIfChangeConnectedPort, ocmIfSaveReference, ocmIfPowerOffset, ocmIfConnectedBoardType, ocmIfChangeConnectedBoardType, ocmIfMaxPowerLevel, ocmIfMinPowerLevel, ocmIfDeltaPower } STATUS deprecated DESCRIPTION "The ocm interface objects." ::= { lumOcmGroups 2 } ocmChannelGroup OBJECT-GROUP OBJECTS { ocmChannelIndex, ocmChannelName, ocmChannelFrequency, ocmChannelPowerLevel, ocmChannelUpdateLastChangeTime, ocmChannelOcmRefIfIndex, ocmChannelReferencePowerLevel } STATUS deprecated DESCRIPTION "The ocm channel objects." ::= { lumOcmGroups 3 } ocmIfGroupV2 OBJECT-GROUP OBJECTS { ocmIfIndex, ocmIfName, ocmIfDescr, ocmIfSubrack, ocmIfSlot, ocmIfRxPort, ocmIfInvPhysIndexOrZero, ocmIfAdminStatus, ocmIfOperStatus, ocmIfPowerThreshold, ocmIfUpdateLastChangeTime, ocmIfConnectedSubrack, ocmIfConnectedSlot, ocmIfConnectedPort, ocmIfActivePort, ocmIfControlMode, ocmIfReferenceTime, ocmIfSwitchFailure, ocmIfDataSourceNotDefined, ocmIfCommissioningMode, ocmIfModuleFailure, ocmIfConfigurationCommand, ocmIfChangeConnectedPort, ocmIfSaveReference, ocmIfPowerOffset, ocmIfConnectedBoardType, ocmIfChangeConnectedBoardType, ocmIfMaxPowerLevel, ocmIfMinPowerLevel, ocmIfDeltaPower, ocmIfChangePowerThreshold, ocmIfChangePowerOffset } STATUS deprecated DESCRIPTION "The ocm interface objects." ::= { lumOcmGroups 4 } ocmIfGroupV3 OBJECT-GROUP OBJECTS { ocmIfIndex, ocmIfName, ocmIfDescr, ocmIfSubrack, ocmIfSlot, ocmIfRxPort, ocmIfInvPhysIndexOrZero, ocmIfAdminStatus, ocmIfOperStatus, ocmIfPowerThreshold, ocmIfUpdateLastChangeTime, ocmIfConnectedSubrack, ocmIfConnectedSlot, ocmIfConnectedPort, ocmIfActivePort, ocmIfControlMode, ocmIfReferenceTime, ocmIfSwitchFailure, ocmIfDataSourceNotDefined, ocmIfCommissioningMode, ocmIfModuleFailure, ocmIfConfigurationCommand, ocmIfChangeConnectedPort, ocmIfSaveReference, ocmIfPowerOffset, ocmIfConnectedBoardType, ocmIfChangeConnectedBoardType, ocmIfMaxPowerLevel, ocmIfMinPowerLevel, ocmIfDeltaPower, ocmIfChangePowerThreshold, ocmIfChangePowerOffset, ocmIfPowerOffsetAdjustment } STATUS deprecated DESCRIPTION "The ocm interface objects." ::= { lumOcmGroups 5 } ocmChannelGroupV2 OBJECT-GROUP OBJECTS { ocmChannelIndex, ocmChannelName, ocmChannelFrequency, ocmChannelPowerLevel, ocmChannelUpdateLastChangeTime, ocmChannelOcmRefIfIndex, ocmChannelReferencePowerLevel, ocmChannelReferenceTime, ocmChannelSaveReference } STATUS current DESCRIPTION "The ocm channel objects." ::= { lumOcmGroups 6 } ocmIfGroupV4 OBJECT-GROUP OBJECTS { ocmIfIndex, ocmIfName, ocmIfDescr, ocmIfSubrack, ocmIfSlot, ocmIfRxPort, ocmIfInvPhysIndexOrZero, ocmIfAdminStatus, ocmIfOperStatus, ocmIfPowerThreshold, ocmIfUpdateLastChangeTime, ocmIfConnectedSubrack, ocmIfConnectedSlot, ocmIfConnectedPort, ocmIfActivePort, ocmIfControlMode, ocmIfReferenceTime, ocmIfSwitchFailure, ocmIfDataSourceNotDefined, ocmIfCommissioningMode, ocmIfModuleFailure, ocmIfConfigurationCommand, ocmIfChangeConnectedPort, ocmIfSaveReference, ocmIfPowerOffset, ocmIfConnectedBoardType, ocmIfChangeConnectedBoardType, ocmIfMaxPowerLevel, ocmIfMinPowerLevel, ocmIfDeltaPower, ocmIfChangePowerThreshold, ocmIfChangePowerOffset, ocmIfPowerOffsetAdjustment, ocmIfSpacingMode, ocmIfHighInputPower } STATUS current DESCRIPTION "The ocm interface objects." ::= { lumOcmGroups 7 } -- ---------------------------------------------------- -- Compliance -- ---------------------------------------------------- lumOcmBasicComplV1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Basic implementation requirements for the OCM MIB V1." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroup, ocmChannelGroup } ::= { lumOcmCompl 1 } lumOcmBasicComplV2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Basic implementation requirements for the OCM MIB V2 (14.0)." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroupV2, ocmChannelGroup } ::= { lumOcmCompl 2 } lumOcmBasicComplV3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Basic implementation requirements for the OCM MIB V2 (23.0)." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroupV3, ocmChannelGroup } ::= { lumOcmCompl 3 } lumOcmBasicComplV4 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Basic implementation requirements for the OCM MIB V2 (30.0)." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroupV3, ocmChannelGroupV2 } ::= { lumOcmCompl 4 } lumOcmBasicComplV5 MODULE-COMPLIANCE STATUS current DESCRIPTION "Basic implementation requirements for the OCM MIB V2 (31.0)." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroupV4, ocmChannelGroupV2 } ::= { lumOcmCompl 5 } -- ---------------------------------------------------- -- Minimal Compliance -- ---------------------------------------------------- lumOcmMinimalComplV1 MODULE-COMPLIANCE STATUS current DESCRIPTION "Minimal implementation requirements for the OCM MIB V1." MODULE MANDATORY-GROUPS { ocmGeneralGroup, ocmIfGroup } ::= { lumOcmMinimalCompl 1 } END