-- Ingrasys iPoManII MIB -- MIB for Intelligent Power Management -- -- { iso org(3) dod(6) internet(1) private(4) enterprises(1) ingrasys(2468) -- product(1) pduAgent(4) iPoManII(1) -- ============================================================================================== --- --- Revision History --- --- v0.80 20-Apr-2005 Ming Lu/Ingrasys --- Created --- --- v0.81 04-Aug-2007 Ming Lu/Ingrasys --- Modify Some error from Web check issue --- Add Slave mib data and control --- --- v0.82 04-Oct-2007 Ming Lu/Ingrasys --- Modify Some error from Web check issue --- --- v1.00 06-Dec-2007 Ming Lu/Ingrasys --- Add Slave trap 26-150 --- --- v1.01 25-Jan-2008 Ming Lu/Ingrasys --- Modify Some mib wording error --- --- v1.02 30-Jan-2008 Ming Lu/Ingrasys --- Modify Some mib wording error --- --- v1.03 09-Apr-2010 Ming Lu/Ingrasys --- Add reset WattItem --- IPOMANII-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; ingrasys OBJECT IDENTIFIER ::= { enterprises 2468 } product OBJECT IDENTIFIER ::= { ingrasys 1 } pduAgent OBJECT IDENTIFIER ::= { product 4 } iPoManII OBJECT IDENTIFIER ::= { pduAgent 2 } ipmObjects OBJECT IDENTIFIER ::= { iPoManII 1 } ipmTraps OBJECT IDENTIFIER ::= { iPoManII 2 } ipmIdent OBJECT IDENTIFIER ::= { ipmObjects 1 } ipmAgent OBJECT IDENTIFIER ::= { ipmObjects 2 } ipmDevice OBJECT IDENTIFIER ::= { ipmObjects 3 } ipmSlave OBJECT IDENTIFIER ::= { ipmObjects 4 } ipmEnv OBJECT IDENTIFIER ::= { ipmObjects 5 } -- =========================================================================== -- -- ipmIdent -- -- iPoManII Identification Group -- -- =========================================================================== ipmIdentManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of manufacturer." ::= { ipmIdent 1 } ipmIdentModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The Model designation of device." ::= { ipmIdent 2 } ipmIdentAgentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version of the device." ::= { ipmIdent 3 } ipmIdentName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A description of this device." ::= { ipmIdent 4 } ipmAgentConfig OBJECT IDENTIFIER ::= { ipmAgent 1 } -- =========================================================================== -- -- ipmConfig -- -- iPoManII Configuration Group, configure the secific features of iPoManII -- -- =========================================================================== ipmAgentMibVersion OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Mib Version implemented on this device." ::= { ipmAgentConfig 1 } ipmAgentTime OBJECT IDENTIFIER ::= { ipmAgent 2 } -- =========================================================================== -- -- ipmConfigTime -- -- Date/Time Configuration Group of the device. -- -- =========================================================================== ipmAgentTimeDate OBJECT-TYPE SYNTAX DisplayString (SIZE (10..10)) ACCESS read-write STATUS mandatory DESCRIPTION "The date in agent, format is (dd/mm/yyyy)" ::= { ipmAgentTime 1 } ipmAgentTimeTime OBJECT-TYPE SYNTAX DisplayString (SIZE (8..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The time in agent, format is (hh:mm:ss)" ::= { ipmAgentTime 2 } ipmAgentTimerFromNtp OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the agent to synchronize date/time with NTP server." ::= { ipmAgentTime 3 } ipmAgentNtpIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ip address of NTP server." ::= { ipmAgentTime 4 } ipmAgentNtpTimeZone OBJECT-TYPE SYNTAX INTEGER { gMT-1200(1), gMT-1100(2), gMT-1000(3), gMT-0900(4), gMT-0800(5), gMT-0700(6), gMT-0600(7), gMT-0500(8), gMT-0400(9), gMT-0330(10), gMT-0300(11), gMT-0200(12), gMT-0100(13), gMT-0000(14), gMT0100(15), gMT0200(16), gMT0300(17), gMT0330(18), gMT0400(19), gMT0500(20), gMT0530(21), gMT0600(22), gMT0700(23), gMT0800(24), gMT0900(25), gMT1000(26), gMT1100(27), gMT1200(28) } ACCESS read-write STATUS mandatory DESCRIPTION "Time Zone to use when synchronize with NTP server." ::= { ipmAgentTime 5 } ipmAgentDayLightSaving OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable the Day Light Saving when synchronize with NTP server." ::= { ipmAgentTime 6 } ipmAgentNetwork OBJECT IDENTIFIER ::= { ipmAgent 3 } -- =========================================================================== -- -- ipmConfigNetwork -- -- Network Configuration Group of the device. -- -- =========================================================================== ipmAgentNetworkIp OBJECT IDENTIFIER ::= { ipmAgentNetwork 1 } -- =========================================================================== -- -- ipmAgentNetworkIp -- -- Ip address Configuration Group of the device. -- -- =========================================================================== ipmAgentNetworkIpAdress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ip address that NMS can identify the managed device." ::= { ipmAgentNetworkIp 1} ipmAgentNetworkIpGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The default gateway that allow device managed through routers." ::= { ipmAgentNetworkIp 2} ipmAgentNetworkIpSubnet OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Internet address subnet mask" ::= { ipmAgentNetworkIp 3} ipmAgentNetworkDhcpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable DHCP protocol" ::= { ipmAgentNetwork 2 } ipmAgentNetworkPingControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable to response to PING request." ::= { ipmAgentNetwork 3 } ipmAgentNetworkTftpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable TFTP protocol" ::= { ipmAgentNetwork 4 } ipmAgentNetworkTelnet OBJECT IDENTIFIER ::= { ipmAgentNetwork 5 } -- =========================================================================== -- -- ipmConfigNetworkTelnet -- -- Telnet Configuration Group of the device. -- -- =========================================================================== ipmAgentTelnetControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable Telnet protocol." ::= { ipmAgentNetworkTelnet 1 } ipmAgentTelnetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port for telnet" ::= { ipmAgentNetworkTelnet 2} ipmAgentNetworkHttp OBJECT IDENTIFIER ::= { ipmAgentNetwork 6 } -- =========================================================================== -- -- ipmConfigNetworkHttp -- -- HTTP Configuration Group of the device. -- -- =========================================================================== ipmAgentHttpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable HTTP protocol." ::= { ipmAgentNetworkHttp 1 } ipmAgentHttpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port for HTTP." ::= { ipmAgentNetworkHttp 2} ipmAgentNetworkSnmp OBJECT IDENTIFIER ::= { ipmAgentNetwork 7 } -- =========================================================================== -- -- ipmAgentNetworkSnmp -- -- SNMP Configuration Group of the device. -- -- =========================================================================== ipmAgentSnmpControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable SNMP protocol." ::= { ipmAgentNetworkSnmp 1 } ipmAgentSnmpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The UDP port for SNMP." ::= { ipmAgentNetworkSnmp 2} ipmAgentLog OBJECT IDENTIFIER ::= { ipmAgentConfig 4 } -- =========================================================================== -- -- ipmConfigLog -- -- Log Configuration Group of the device. -- -- =========================================================================== pduAgentDataLogInterval OBJECT-TYPE SYNTAX INTEGER (60..28800) -- in seconds ACCESS read-write STATUS mandatory DESCRIPTION "The interval of the updation of the data log. The value is in seconds" ::= { ipmAgentLog 1 } ipmAgentControl OBJECT IDENTIFIER ::= { ipmAgentConfig 5 } -- =========================================================================== -- -- ipmAgentAgentControl -- -- Agent Control Configuration Group of the device. -- -- =========================================================================== ipmAgentControlDefault OBJECT-TYPE SYNTAX INTEGER { reset(1), nothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all parameters of the agent to default value." ::= { ipmAgentControl 1} ipmAgentControlRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), nothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart the agent." ::= { ipmAgentControl 2} ipmAgentTrap OBJECT IDENTIFIER ::= { ipmAgentConfig 6 } -- =========================================================================== -- -- ipmAgentTrap -- -- Trap Configuration Group of the agent. -- -- =========================================================================== ipmAgentTrapRetryCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The count of repeat traps send to NMS before trap acknowledgement received." ::= { ipmAgentTrap 1} ipmAgentTrapRetryTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time interval in seconds between retry traps sned to NMS." ::= { ipmAgentTrap 2} ipmAgentTrapAckSignature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The signature of trap acknowledgement." ::= { ipmAgentTrap 3} -- =========================================================================== -- -- ipmAgentTrapsReceiversTable -- -- =========================================================================== ipmAgentTrapsReceiversTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmAgentTrapsReceiversEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of managers to send traps to. The number of entries is given by the value of agentConfigNumTrapReceivers" ::= { ipmAgentConfig 7} ipmAgentTrapsReceiversEntry OBJECT-TYPE SYNTAX IpmAgentTrapsReceiversEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The managers to send traps to." INDEX { trapsIndex } ::= { ipmAgentTrapsReceiversTable 1 } IpmAgentTrapsReceiversEntry ::= SEQUENCE { trapsIndex INTEGER, trapsReceiverAddr IpAddress, receiverCommunityString DisplayString, receiverNmsType INTEGER, receiverSeverityLevel INTEGER, receiverDescription DisplayString } trapsIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a trap receiver entry." ::= { ipmAgentTrapsReceiversEntry 1 } trapsReceiverAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the manager to send a trap to." ::= { ipmAgentTrapsReceiversEntry 2 } receiverCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The community name to use in the trap when sent to the manager." ::= { ipmAgentTrapsReceiversEntry 3 } receiverNmsType OBJECT-TYPE SYNTAX INTEGER { none(1), iPoManII-trap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trap group that NMS desired." ::= { ipmAgentTrapsReceiversEntry 4 } receiverSeverityLevel OBJECT-TYPE SYNTAX INTEGER { informational(1), warning(2), severe(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The severity level of traps to be received by this manager." ::= { ipmAgentTrapsReceiversEntry 5 } receiverDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Description of trap receivers" ::= { ipmAgentTrapsReceiversEntry 6 } -- =========================================================================== -- -- ipmAgentAccessControlTable -- -- =========================================================================== ipmAgentAccessControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmAgentAccessControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of managers which can access the device with private community string." ::= { ipmAgentConfig 8} ipmAgentAccessControlEntry OBJECT-TYPE SYNTAX IpmAgentAccessControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The managers." INDEX { accessIndex} ::= { ipmAgentAccessControlTable 1 } IpmAgentAccessControlEntry ::= SEQUENCE { accessIndex INTEGER, accessControlAddr IpAddress, accessControlMode INTEGER } accessIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access control entry." ::= { ipmAgentAccessControlEntry 1 } accessControlAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the manager to access the device." ::= { ipmAgentAccessControlEntry 2 } accessControlMode OBJECT-TYPE SYNTAX INTEGER { permitted (1), denied (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Access type, only read/Write access type can change parameter of the device." ::= { ipmAgentAccessControlEntry 3 } ipmDeviceInlet OBJECT IDENTIFIER ::= { ipmDevice 1 } -- =========================================================================== -- -- ipmDeviceInlet -- -- Inlet Group -- -- =========================================================================== ipmDeviceInletNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The inlet number on this device." ::= { ipmDeviceInlet 1} ipmDeviceInletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipmDeviceInlet 2} ipmDeviceInletConfigEntry OBJECT-TYPE SYNTAX IpmDeviceInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletConfigIndex} ::= { ipmDeviceInletConfigTable 1 } IpmDeviceInletConfigEntry ::= SEQUENCE { inletConfigIndex INTEGER, inletConfigDesc DisplayString, inletConfigVoltageHigh INTEGER, inletConfigVoltageHighAction INTEGER, inletConfigVoltageLow INTEGER, inletConfigVoltageLowAction INTEGER, inletConfigCurrentHigh INTEGER, inletConfigCurrentHighAction INTEGER, inletConfigFrequencyHigh INTEGER, inletConfigfrequencyHighAction INTEGER, inletConfigFrequencyLow INTEGER, inletConfigfrequencyLowAction INTEGER } inletConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipmDeviceInletConfigEntry 1 } inletConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of inlet of device." ::= { ipmDeviceInletConfigEntry 2 } inletConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high voltage threshold, in volts." ::= { ipmDeviceInletConfigEntry 3 } inletConfigVoltageHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet voltage higher than set point." ::= { ipmDeviceInletConfigEntry 4 } inletConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipmDeviceInletConfigEntry 5 } inletConfigVoltageLowAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet voltage lower than set point." ::= { ipmDeviceInletConfigEntry 6 } inletConfigCurrentHigh OBJECT-TYPE SYNTAX INTEGER (1..160) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in 0.1 amps." ::= { ipmDeviceInletConfigEntry 7 } inletConfigCurrentHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet current higher than set point." ::= { ipmDeviceInletConfigEntry 8 } inletConfigFrequencyHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high frequency threshold, in hz." ::= { ipmDeviceInletConfigEntry 9 } inletConfigfrequencyHighAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet frequency higher than set point." ::= { ipmDeviceInletConfigEntry 10 } inletConfigFrequencyLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low frequency threshold, in hz." ::= { ipmDeviceInletConfigEntry 11 } inletConfigfrequencyLowAction OBJECT-TYPE SYNTAX INTEGER { outletsOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when inlet frequency lower than set point." ::= { ipmDeviceInletConfigEntry 12 } ipmDeviceInletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipmDeviceInlet 3} ipmDeviceInletStatusEntry OBJECT-TYPE SYNTAX IpmDeviceInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletStatusIndex} ::= { ipmDeviceInletStatusTable 1 } IpmDeviceInletStatusEntry ::= SEQUENCE { inletStatusIndex INTEGER, inletStatusVoltage INTEGER, inletStatusCurrent INTEGER, inletStatusFrequency INTEGER, inletStatusKwatt INTEGER, inletStatusWH INTEGER } inletStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipmDeviceInletStatusEntry 1 } inletStatusVoltage OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipmDeviceInletStatusEntry 2 } inletStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipmDeviceInletStatusEntry 3 } inletStatusFrequency OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipmDeviceInletStatusEntry 4 } inletStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.1 KW/H" ::= { ipmDeviceInletStatusEntry 5 } inletStatusWH OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.1 W/H" ::= { ipmDeviceInletStatusEntry 6 } inletWattReset OBJECT-TYPE SYNTAX INTEGER { none(1), inlet1(2), inlet2(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset inlet kw." ::= { ipmDeviceInlet 4} ipmDeviceOutlet OBJECT IDENTIFIER ::= { ipmDevice 2 } -- =========================================================================== -- -- ipmDeviceOutlet -- -- Inlet Group -- -- =========================================================================== ipmDeviceOutletNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet number on this device." ::= { ipmDeviceOutlet 1} ipmDeviceOutletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceOutletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmDeviceOutlet 2} ipmDeviceOutletConfigEntry OBJECT-TYPE SYNTAX IpmDeviceOutletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletConfigIndex} ::= { ipmDeviceOutletConfigTable 1 } IpmDeviceOutletConfigEntry ::= SEQUENCE { outletConfigIndex INTEGER, outletConfigDesc DisplayString, outletConfigLocation DisplayString, outletConfigOnDelay INTEGER, outletConfigOffDelay INTEGER, outletConfigCurrentHigh INTEGER, outletConfigCurrentHighAction INTEGER } outletConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipmDeviceOutletConfigEntry 1 } outletConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of outlet of device." ::= { ipmDeviceOutletConfigEntry 2 } outletConfigLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Location of device connectted to this outlet." ::= { ipmDeviceOutletConfigEntry 3 } outletConfigOnDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmDeviceOutletConfigEntry 4 } outletConfigOffDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn off tis outlet, in seconds." ::= { ipmDeviceOutletConfigEntry 5 } outletConfigCurrentHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The outlet high current threshold, in amp." ::= { ipmDeviceOutletConfigEntry 6 } outletConfigCurrentHighAction OBJECT-TYPE SYNTAX INTEGER { outletOff (1), nothing (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reaction of the device when outlet current higher than set point." ::= { ipmDeviceOutletConfigEntry 7 } ipmDeviceOutletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceOutletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmDeviceOutlet 3} ipmDeviceOutletStatusEntry OBJECT-TYPE SYNTAX IpmDeviceOutletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { outletStatusIndex} ::= { ipmDeviceOutletStatusTable 1 } IpmDeviceOutletStatusEntry ::= SEQUENCE { outletStatusIndex INTEGER, outletStatusStatus INTEGER, outletStatusCurrent INTEGER, outletStatusKwatt INTEGER, outletStatusWH INTEGER, outletStatusStateTime INTEGER, outletStatusTimeToGo INTEGER } outletStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmDeviceOutletStatusEntry 1 } outletStatusStatus OBJECT-TYPE SYNTAX INTEGER { unknow (1), outletOff (2), outletOn (3), outletOffToOn (4), outletOnToOff (5), outletCycling (6) } ACCESS read-only STATUS mandatory DESCRIPTION "Outlet state" ::= { ipmDeviceOutletStatusEntry 2 } outletStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Current in 0.001 Amp." ::= { ipmDeviceOutletStatusEntry 3 } outletStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Kwatt in 0.001 KW/H." ::= { ipmDeviceOutletStatusEntry 4 } outletStatusWH OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The outlet Watt in 0.1 W/H." ::= { ipmDeviceOutletStatusEntry 5 } outletStatusStateTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds since the outlet changed to current state." ::= { ipmDeviceOutletStatusEntry 6 } outletStatusTimeToGo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remain time the outlet state will be changed by agent, in seconds" ::= { ipmDeviceOutletStatusEntry 7 } ipmDeviceOutletControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceOutletControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmDeviceOutlet 4} ipmDeviceOutletControlEntry OBJECT-TYPE SYNTAX IpmDeviceOutletControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { outletControlIndex} ::= { ipmDeviceOutletControlTable 1 } IpmDeviceOutletControlEntry ::= SEQUENCE { outletControlIndex INTEGER, outletControlControl INTEGER } outletControlIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmDeviceOutletControlEntry 1 } outletControlControl OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmDeviceOutletControlEntry 2 } ipmDeviceOutletControlAll OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimers(6), offByActionTimers(7), cycleByActionTimers(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control all outlets perform action as requested." ::= { ipmDeviceOutlet 5} ipmDeviceOutletWattReset OBJECT-TYPE SYNTAX INTEGER { none(1), outleta(2), outletb(3), outletc(4), outletd(5), outlete(6), outletf(7), outletg(8), outleth(9), outleti(10), outletj(11), outletk(12), outletl(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset outlet kw." ::= { ipmDeviceOutlet 6} ipmDeviceCcOut OBJECT IDENTIFIER ::= { ipmDevice 3 } -- =========================================================================== -- -- ipmDeviceCCOut -- -- Contact Closure Output Group -- -- =========================================================================== ipmDeviceCcOutNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The contact closure output number on this device." ::= { ipmDeviceCcOut 1} ipmDeviceCcOutConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceCcOutConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipmDeviceCcOut 2} ipmDeviceCcOutConfigEntry OBJECT-TYPE SYNTAX IpmDeviceCcOutConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The CC number of device." INDEX { ccOutConfigIndex} ::= { ipmDeviceCcOutConfigTable 1 } IpmDeviceCcOutConfigEntry ::= SEQUENCE { ccOutConfigIndex INTEGER, ccOutConfigDesc DisplayString, ccOutConfigEventAction INTEGER, ccOutConfigCloseDelay INTEGER, ccOutConfigOpenDelay INTEGER } ccOutConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to access contact closure output configuration table." ::= { ipmDeviceCcOutConfigEntry 1 } ccOutConfigDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a contact closure output of device." ::= { ipmDeviceCcOutConfigEntry 2 } ccOutConfigEventAction OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disble the contact closure output to react to events." ::= { ipmDeviceCcOutConfigEntry 3 } ccOutConfigCloseDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time in seconds when the contact closure output set to close." ::= { ipmDeviceCcOutConfigEntry 4 } ccOutConfigOpenDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time in seconds when the contact closure output set to open." ::= { ipmDeviceCcOutConfigEntry 5 } ipmDeviceCcOutStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceCcOutStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipmDeviceCcOut 3} ipmDeviceCcOutStatusEntry OBJECT-TYPE SYNTAX IpmDeviceCcOutStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The CC number of device." INDEX { ccOutStatusIndex} ::= { ipmDeviceCcOutStatusTable 1 } IpmDeviceCcOutStatusEntry ::= SEQUENCE { ccOutStatusIndex INTEGER, ccOutStatusStatus INTEGER, ccOutStatusTimeOnState INTEGER } ccOutStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to access contact closure output configuration table." ::= { ipmDeviceCcOutStatusEntry 1 } ccOutStatusStatus OBJECT-TYPE SYNTAX INTEGER { closed (1), open (2) } ACCESS read-only STATUS mandatory DESCRIPTION "State of a contact closure output of device." ::= { ipmDeviceCcOutStatusEntry 2 } ccOutStatusTimeOnState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds since the contact closure output changed to current state." ::= { ipmDeviceCcOutStatusEntry 3 } ipmDeviceCcOutControlTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceCcOutControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact closure output on this device." ::= { ipmDeviceCcOut 4} ipmDeviceCcOutControlEntry OBJECT-TYPE SYNTAX IpmDeviceCcOutControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { ccOutControlIndex} ::= { ipmDeviceCcOutControlTable 1 } IpmDeviceCcOutControlEntry ::= SEQUENCE { ccOutControlIndex INTEGER, ccOutControlControl INTEGER } ccOutControlIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access contact closure output configuration table." ::= { ipmDeviceCcOutControlEntry 1 } ccOutControlControl OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), closeImmediately(3), openImmediately(4), cycleImmediately(5), closeByCloseTimer(6), openByOpenTimer(7), cycleByActionTimer(8), closeThenOpenByActionTimers(9), openThenCloseByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the contact closure output perform action as requested." ::= { ipmDeviceCcOutControlEntry 2 } ipmSlaveState OBJECT IDENTIFIER ::= { ipmSlave 1 } -- =========================================================================== -- -- ipmSlaveState -- -- Daisy Chain Device Group -- -- =========================================================================== -- ipmSlaveStateTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveState 1} ipmSlaveStateEntry OBJECT-TYPE SYNTAX IpmSlaveStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveStateIndex} ::= { ipmSlaveStateTable 1 } IpmSlaveStateEntry ::= SEQUENCE { slaveStateIndex INTEGER, slaveStateControl01 INTEGER } slaveStateIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveStateEntry 1 } slaveStateControl01 OBJECT-TYPE SYNTAX INTEGER { disconnected(1), connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested to slave outlet A" ::= { ipmSlaveStateEntry 2 } ipmSlaveInlet OBJECT IDENTIFIER ::= { ipmSlave 2 } -- =========================================================================== -- -- ipmSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipmSlaveInletStatus OBJECT IDENTIFIER ::= { ipmSlaveInlet 1 } -- =========================================================================== -- -- ipmSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipmDeviceSlaveInletStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceSlaveInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipmSlaveInletStatus 1} ipmDeviceSlaveInletStatusEntry OBJECT-TYPE SYNTAX IpmDeviceSlaveInletStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { inletStatusIndex} ::= { ipmDeviceSlaveInletStatusTable 1 } IpmDeviceSlaveInletStatusEntry ::= SEQUENCE { inletSlaveStatusIndex INTEGER, inletSlaveStatusVoltage INTEGER, inletSlaveStatusCurrent INTEGER, inletSlaveStatusFrequency INTEGER, inletSlaveStatusKwatt INTEGER, inletSlaveStatusWH INTEGER, inletSlaveStatusVoltage2 INTEGER, inletSlaveStatusCurrent2 INTEGER, inletSlaveStatusFrequency2 INTEGER, inletSlaveStatusKwatt2 INTEGER, inletSlaveStatusWH2 INTEGER } inletSlaveStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipmDeviceSlaveInletStatusEntry 1 } inletSlaveStatusVoltage OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipmDeviceSlaveInletStatusEntry 2 } inletSlaveStatusCurrent OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipmDeviceSlaveInletStatusEntry 3 } inletSlaveStatusFrequency OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipmDeviceSlaveInletStatusEntry 4 } inletSlaveStatusKwatt OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipmDeviceSlaveInletStatusEntry 5 } inletSlaveStatusWH OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipmDeviceSlaveInletStatusEntry 6 } inletSlaveStatusVoltage2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Voltage in 0.1 volts" ::= { ipmDeviceSlaveInletStatusEntry 7 } inletSlaveStatusCurrent2 OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Current in 0.001 Amp." ::= { ipmDeviceSlaveInletStatusEntry 8 } inletSlaveStatusFrequency2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Frequency in 0.1 Hz" ::= { ipmDeviceSlaveInletStatusEntry 9 } inletSlaveStatusKwatt2 OBJECT-TYPE SYNTAX INTEGER (0..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipmDeviceSlaveInletStatusEntry 10 } inletSlaveStatusWH2 OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-only STATUS mandatory DESCRIPTION "The Inlet Kwatt in 0.001 KW/H" ::= { ipmDeviceSlaveInletStatusEntry 11 } ipmSlaveInletConfig OBJECT IDENTIFIER ::= { ipmSlaveInlet 2 } -- =========================================================================== -- -- ipmSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipmDeviceslaveInletConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmDeviceslaveInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inlet on this device." ::= { ipmSlaveInletConfig 1} ipmDeviceslaveInletConfigEntry OBJECT-TYPE SYNTAX IpmDeviceslaveInletConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The inlet number of device." INDEX { slaveInletConfigIndex} ::= { ipmDeviceslaveInletConfigTable 1 } IpmDeviceslaveInletConfigEntry ::= SEQUENCE { slaveInletConfigIndex INTEGER, slaveInletConfigVoltageHigh INTEGER, slaveInletConfigVoltageLow INTEGER, slaveInlet2ConfigVoltageHigh INTEGER, slaveInlet2ConfigVoltageLow INTEGER } slaveInletConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access inlet configuration table." ::= { ipmDeviceslaveInletConfigEntry 1 } slaveInletConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet high voltage threshold, in volts." ::= { ipmDeviceslaveInletConfigEntry 2 } slaveInletConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipmDeviceslaveInletConfigEntry 3 } slaveInlet2ConfigVoltageHigh OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet 2 high voltage threshold, in volts." ::= { ipmDeviceslaveInletConfigEntry 4 } slaveInlet2ConfigVoltageLow OBJECT-TYPE SYNTAX INTEGER (1..65500) -- ACCESS read-write STATUS mandatory DESCRIPTION "The Inlet low voltage threshold, in volts." ::= { ipmDeviceslaveInletConfigEntry 5 } ipmSlaveOutlet OBJECT IDENTIFIER ::= { ipmSlave 3 } -- =========================================================================== -- -- ipmSlaveAllDevice -- -- Daisy Chain Device Group -- -- =========================================================================== ipmSlaveOutletConfig OBJECT IDENTIFIER ::= { ipmSlaveOutlet 1 } -- =========================================================================== -- -- ipmOutletConfig -- -- Outlet Config Group -- -- =========================================================================== -- -- Outlet Name Description -- ipmSlaveDeviceOutletNameTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletNameEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletConfig 1} ipmSlaveDeviceOutletNameEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletNameEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletNameIndex} ::= { ipmSlaveDeviceOutletNameTable 1 } IpmSlaveDeviceOutletNameEntry ::= SEQUENCE { slaveOutletNameIndex INTEGER, slaveOutletName01 DisplayString, slaveOutletName02 DisplayString, slaveOutletName03 DisplayString, slaveOutletName04 DisplayString, slaveOutletName05 DisplayString, slaveOutletName06 DisplayString, slaveOutletName07 DisplayString, slaveOutletName08 DisplayString, slaveOutletName09 DisplayString, slaveOutletName10 DisplayString, slaveOutletName11 DisplayString, slaveOutletName12 DisplayString } slaveOutletNameIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletNameEntry 1 } slaveOutletName01 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 2 } slaveOutletName02 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 3 } slaveOutletName03 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 4 } slaveOutletName04 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 5 } slaveOutletName05 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 6 } slaveOutletName06 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 7 } slaveOutletName07 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 8 } slaveOutletName08 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 9 } slaveOutletName09 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 10 } slaveOutletName10 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 11 } slaveOutletName11 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 12 } slaveOutletName12 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletNameEntry 13 } -- =============================== -- Outlet Location Description -- =============================== ipmSlaveDeviceOutletLocationTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletLocationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletConfig 2} ipmSlaveDeviceOutletLocationEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletLocationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletLocationIndex} ::= { ipmSlaveDeviceOutletLocationTable 1 } IpmSlaveDeviceOutletLocationEntry ::= SEQUENCE { slaveOutletLocationIndex INTEGER, slaveOutletLocation01 DisplayString, slaveOutletLocation02 DisplayString, slaveOutletLocation03 DisplayString, slaveOutletLocation04 DisplayString, slaveOutletLocation05 DisplayString, slaveOutletLocation06 DisplayString, slaveOutletLocation07 DisplayString, slaveOutletLocation08 DisplayString, slaveOutletLocation09 DisplayString, slaveOutletLocation10 DisplayString, slaveOutletLocation11 DisplayString, slaveOutletLocation12 DisplayString } slaveOutletLocationIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletLocationEntry 1 } slaveOutletLocation01 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 2 } slaveOutletLocation02 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 3 } slaveOutletLocation03 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 4 } slaveOutletLocation04 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 5 } slaveOutletLocation05 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 6 } slaveOutletLocation06 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 7 } slaveOutletLocation07 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 8 } slaveOutletLocation08 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 9 } slaveOutletLocation09 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 10 } slaveOutletLocation10 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 11 } slaveOutletLocation11 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 12 } slaveOutletLocation12 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A Description of a outlet name of device." ::= { ipmSlaveDeviceOutletLocationEntry 13 } -- ========================================== -- Outlet On Delay Time -- ========================================== ipmSlaveDeviceOutletOnTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletConfig 3} ipmSlaveDeviceOutletOnTimeEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletOnTimeIndex} ::= { ipmSlaveDeviceOutletOnTimeTable 1 } IpmSlaveDeviceOutletOnTimeEntry ::= SEQUENCE { slaveOutletOnTimeIndex INTEGER, slaveOutletOnTime01 INTEGER, slaveOutletOnTime02 INTEGER, slaveOutletOnTime03 INTEGER, slaveOutletOnTime04 INTEGER, slaveOutletOnTime05 INTEGER, slaveOutletOnTime06 INTEGER, slaveOutletOnTime07 INTEGER, slaveOutletOnTime08 INTEGER, slaveOutletOnTime09 INTEGER, slaveOutletOnTime10 INTEGER, slaveOutletOnTime11 INTEGER, slaveOutletOnTime12 INTEGER } slaveOutletOnTimeIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletOnTimeEntry 1 } slaveOutletOnTime01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 2 } slaveOutletOnTime02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 3 } slaveOutletOnTime03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 4 } slaveOutletOnTime04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 5 } slaveOutletOnTime05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 6 } slaveOutletOnTime06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 7 } slaveOutletOnTime07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 8 } slaveOutletOnTime08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 9 } slaveOutletOnTime09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 10 } slaveOutletOnTime10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 11 } slaveOutletOnTime11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 12 } slaveOutletOnTime12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOnTimeEntry 13 } -- ========================================== -- Outlet Off Delay Time -- ========================================== ipmSlaveDeviceOutletOffTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletOffTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletConfig 4} ipmSlaveDeviceOutletOffTimeEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletOffTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletOffTimeIndex} ::= { ipmSlaveDeviceOutletOffTimeTable 1 } IpmSlaveDeviceOutletOffTimeEntry ::= SEQUENCE { slaveOutletOffTimeIndex INTEGER, slaveOutletOffTime01 INTEGER, slaveOutletOffTime02 INTEGER, slaveOutletOffTime03 INTEGER, slaveOutletOffTime04 INTEGER, slaveOutletOffTime05 INTEGER, slaveOutletOffTime06 INTEGER, slaveOutletOffTime07 INTEGER, slaveOutletOffTime08 INTEGER, slaveOutletOffTime09 INTEGER, slaveOutletOffTime10 INTEGER, slaveOutletOffTime11 INTEGER, slaveOutletOffTime12 INTEGER } slaveOutletOffTimeIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletOffTimeEntry 1 } slaveOutletOffTime01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 2 } slaveOutletOffTime02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 3 } slaveOutletOffTime03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 4 } slaveOutletOffTime04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 5 } slaveOutletOffTime05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 6 } slaveOutletOffTime06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 7 } slaveOutletOffTime07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 8 } slaveOutletOffTime08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 9 } slaveOutletOffTime09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 10 } slaveOutletOffTime10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 11 } slaveOutletOffTime11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 12 } slaveOutletOffTime12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The delay time before turn on tis outlet, in seconds." ::= { ipmSlaveDeviceOutletOffTimeEntry 13 } -- ========================================== -- Outlet Current TH -- ========================================== ipmSlaveDeviceOutletCurrThTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletCurrThEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletConfig 5} ipmSlaveDeviceOutletCurrThEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletCurrThEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletCurrThIndex} ::= { ipmSlaveDeviceOutletCurrThTable 1 } IpmSlaveDeviceOutletCurrThEntry ::= SEQUENCE { slaveOutletCurrThIndex INTEGER, slaveOutletCurrTh01 INTEGER, slaveOutletCurrTh02 INTEGER, slaveOutletCurrTh03 INTEGER, slaveOutletCurrTh04 INTEGER, slaveOutletCurrTh05 INTEGER, slaveOutletCurrTh06 INTEGER, slaveOutletCurrTh07 INTEGER, slaveOutletCurrTh08 INTEGER, slaveOutletCurrTh09 INTEGER, slaveOutletCurrTh10 INTEGER, slaveOutletCurrTh11 INTEGER, slaveOutletCurrTh12 INTEGER } slaveOutletCurrThIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletCurrThEntry 1 } slaveOutletCurrTh01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 2 } slaveOutletCurrTh02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 3 } slaveOutletCurrTh03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 4 } slaveOutletCurrTh04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 5 } slaveOutletCurrTh05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 6 } slaveOutletCurrTh06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 7 } slaveOutletCurrTh07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 8 } slaveOutletCurrTh08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 9 } slaveOutletCurrTh09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 10 } slaveOutletCurrTh10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 11 } slaveOutletCurrTh11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 12 } slaveOutletCurrTh12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Outlet Current Threshold ,in 0.1 Amp." ::= { ipmSlaveDeviceOutletCurrThEntry 13 } ipmSlaveOutletStatus OBJECT IDENTIFIER ::= { ipmSlaveOutlet 2 } -- =========================================================================== -- -- ipmOutletStatus -- -- Outlet Status Group -- -- =========================================================================== -- ========================================== -- Outlet Current -- ========================================== ipmSlaveDeviceOutletCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletStatus 1} ipmSlaveDeviceOutletCurrentEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletCurrentIndex} ::= { ipmSlaveDeviceOutletCurrentTable 1 } IpmSlaveDeviceOutletCurrentEntry ::= SEQUENCE { slaveOutletCurrentIndex INTEGER, slaveOutletCurrent01 INTEGER, slaveOutletCurrent02 INTEGER, slaveOutletCurrent03 INTEGER, slaveOutletCurrent04 INTEGER, slaveOutletCurrent05 INTEGER, slaveOutletCurrent06 INTEGER, slaveOutletCurrent07 INTEGER, slaveOutletCurrent08 INTEGER, slaveOutletCurrent09 INTEGER, slaveOutletCurrent10 INTEGER, slaveOutletCurrent11 INTEGER, slaveOutletCurrent12 INTEGER } slaveOutletCurrentIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletCurrentEntry 1 } slaveOutletCurrent01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 2 } slaveOutletCurrent02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 3 } slaveOutletCurrent03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 4 } slaveOutletCurrent04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 5 } slaveOutletCurrent05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 6 } slaveOutletCurrent06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 7 } slaveOutletCurrent07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 8 } slaveOutletCurrent08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 9 } slaveOutletCurrent09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 10 } slaveOutletCurrent10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 11 } slaveOutletCurrent11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 12 } slaveOutletCurrent12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Current in 0.001 Amp." ::= { ipmSlaveDeviceOutletCurrentEntry 13 } -- ========================================== -- Outlet W/H -- ========================================== ipmSlaveDeviceOutletWattTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletWattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletStatus 2} ipmSlaveDeviceOutletWattEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletWattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletWattIndex} ::= { ipmSlaveDeviceOutletWattTable 1 } IpmSlaveDeviceOutletWattEntry ::= SEQUENCE { slaveOutletWattIndex INTEGER, slaveOutletWatt01 INTEGER, slaveOutletWatt02 INTEGER, slaveOutletWatt03 INTEGER, slaveOutletWatt04 INTEGER, slaveOutletWatt05 INTEGER, slaveOutletWatt06 INTEGER, slaveOutletWatt07 INTEGER, slaveOutletWatt08 INTEGER, slaveOutletWatt09 INTEGER, slaveOutletWatt10 INTEGER, slaveOutletWatt11 INTEGER, slaveOutletWatt12 INTEGER } slaveOutletWattIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletWattEntry 1 } slaveOutletWatt01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 2 } slaveOutletWatt02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 3 } slaveOutletWatt03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 4 } slaveOutletWatt04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 5 } slaveOutletWatt05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 6 } slaveOutletWatt06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 7 } slaveOutletWatt07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 8 } slaveOutletWatt08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 9 } slaveOutletWatt09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 10 } slaveOutletWatt10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 11 } slaveOutletWatt11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 12 } slaveOutletWatt12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Watt in 0.1 W/H." ::= { ipmSlaveDeviceOutletWattEntry 13 } -- ========================================== -- Outlet W/H -- ========================================== ipmSlaveDeviceOutletKwattTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletKwattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletStatus 3} ipmSlaveDeviceOutletKwattEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletKwattEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletKwattIndex} ::= { ipmSlaveDeviceOutletKwattTable 1 } IpmSlaveDeviceOutletKwattEntry ::= SEQUENCE { slaveOutletKwattIndex INTEGER, slaveOutletKwatt01 INTEGER, slaveOutletKwatt02 INTEGER, slaveOutletKwatt03 INTEGER, slaveOutletKwatt04 INTEGER, slaveOutletKwatt05 INTEGER, slaveOutletKwatt06 INTEGER, slaveOutletKwatt07 INTEGER, slaveOutletKwatt08 INTEGER, slaveOutletKwatt09 INTEGER, slaveOutletKwatt10 INTEGER, slaveOutletKwatt11 INTEGER, slaveOutletKwatt12 INTEGER } slaveOutletKwattIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletKwattEntry 1 } slaveOutletKwatt01 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet A Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 2 } slaveOutletKwatt02 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet B Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 3 } slaveOutletKwatt03 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet C Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 4 } slaveOutletKwatt04 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet D Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 5 } slaveOutletKwatt05 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet E Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 6 } slaveOutletKwatt06 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet F Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 7 } slaveOutletKwatt07 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet G Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 8 } slaveOutletKwatt08 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet H Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 9 } slaveOutletKwatt09 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet I Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 10 } slaveOutletKwatt10 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet J Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 11 } slaveOutletKwatt11 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet K Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 12 } slaveOutletKwatt12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The outlet L Kwatt in 0.001 KW/H." ::= { ipmSlaveDeviceOutletKwattEntry 13 } ipmSlaveOutletAction OBJECT IDENTIFIER ::= { ipmSlaveOutlet 3 } -- =========================================================================== -- -- ipmOutletStatus -- -- Outlet Action Group -- -- =========================================================================== ipmSlaveDeviceOutletActionTable OBJECT-TYPE SYNTAX SEQUENCE OF IpmSlaveDeviceOutletActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of outlet on this device." ::= { ipmSlaveOutletAction 1} ipmSlaveDeviceOutletActionEntry OBJECT-TYPE SYNTAX IpmSlaveDeviceOutletActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The outlet number of device." INDEX { slaveOutletActionIndex} ::= { ipmSlaveDeviceOutletActionTable 1 } IpmSlaveDeviceOutletActionEntry ::= SEQUENCE { slaveOutletActionIndex INTEGER, slaveOutletAction01 INTEGER, slaveOutletAction02 INTEGER, slaveOutletAction03 INTEGER, slaveOutletAction04 INTEGER, slaveOutletAction05 INTEGER, slaveOutletAction06 INTEGER, slaveOutletAction07 INTEGER, slaveOutletAction08 INTEGER, slaveOutletAction09 INTEGER, slaveOutletAction10 INTEGER, slaveOutletAction11 INTEGER, slaveOutletAction12 INTEGER } slaveOutletActionIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index to a access outlet configuration table." ::= { ipmSlaveDeviceOutletActionEntry 1 } slaveOutletAction01 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 2 } slaveOutletAction02 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 3 } slaveOutletAction03 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 4 } slaveOutletAction04 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 5 } slaveOutletAction05 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 6 } slaveOutletAction06 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 7 } slaveOutletAction07 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 8 } slaveOutletAction08 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 9 } slaveOutletAction09 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 10 } slaveOutletAction10 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 11 } slaveOutletAction11 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 12 } slaveOutletAction12 OBJECT-TYPE SYNTAX INTEGER { none(1), cancelAction(2), onImmediately(3), offImmediately(4), cycleImmediately(5), onByActionTimer(6), offByActionTimer(7), cycleByActionTimer(8), onThenOffByActionTimers(9), offThenOnByActionTimers(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to control the outlet perform action as requested." ::= { ipmSlaveDeviceOutletActionEntry 13 } ipmEnvEmd OBJECT IDENTIFIER ::= { ipmEnv 1 } -- =========================================================================== -- -- ipmEnvEmd -- -- Environmental Monitor Device Group -- -- =========================================================================== ipmEnvEmdStatus OBJECT IDENTIFIER ::= { ipmEnvEmd 1 } -- =========================================================================== -- -- ipmEnvEmd -- -- Environmental Monitor Device Status Group -- -- =========================================================================== ipmEnvEmdStatusEmdType OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), eMD-HT(3), eMD-T(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Type." ::= { ipmEnvEmdStatus 1 } ipmEnvEmdStatusTemperature OBJECT-TYPE SYNTAX INTEGER (1..10000) -- ACCESS read-only STATUS mandatory DESCRIPTION "EMD Temperature in 0.1 degree C." ::= { ipmEnvEmdStatus 2 } ipmEnvEmdStatusHumidity OBJECT-TYPE SYNTAX INTEGER (1..10000) -- ACCESS read-only STATUS mandatory DESCRIPTION "EMD Humidity in 0.1%." ::= { ipmEnvEmdStatus 3 } ipmEnvEmdStatusAlarm1 OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), alarm(3), normal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Alarm-1 state." ::= { ipmEnvEmdStatus 4 } ipmEnvEmdStatusAlarm2 OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), alarm(3), normal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "EMD Alarm-2 state." ::= { ipmEnvEmdStatus 5 } ipmEnvEmdConfig OBJECT IDENTIFIER ::= { ipmEnvEmd 2 } -- =========================================================================== -- -- ipmEnvEmd -- -- Environmental Monitor Device Configuration Group -- -- =========================================================================== ipmEnvEmdConfigEmdPresence OBJECT-TYPE SYNTAX INTEGER { disabled(1), autoDetect(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configure the EMD presence by auto-detect or not exist (disabled)." ::= { ipmEnvEmdConfig 1 } ipmEnvEmdConfigEmdName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of Emd." ::= { ipmEnvEmdConfig 2 } ipmEnvEmdConfigTemp OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 3 } -- =========================================================================== -- -- ipmEnvEmdConfigTemp -- -- Environmental Monitor Device Temperature Configuration Group -- -- =========================================================================== ipmEnvEmdConfigTempName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Temperature sensor." ::= { ipmEnvEmdConfigTemp 1 } ipmEnvEmdConfigTempHighSetPoint OBJECT-TYPE SYNTAX INTEGER (5..65) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD Temperature set point high, alarm will active when temperature over this value, in degree C." ::= { ipmEnvEmdConfigTemp 2 } ipmEnvEmdConfigTempHighStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipmEnvEmdConfigTemp 3 } ipmEnvEmdConfigTempLowSetPoint OBJECT-TYPE SYNTAX INTEGER (5..65) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD Temperature set point high, alarm will active when temperature under this value, in degree C." ::= { ipmEnvEmdConfigTemp 4 } ipmEnvEmdConfigTempLowStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the low setpoint be applied or not" ::= { ipmEnvEmdConfigTemp 5 } ipmEnvEmdConfigTempOffset OBJECT-TYPE SYNTAX INTEGER { t0p0(1), t0p5(2), t1p0(3), t1p5(4), t2p0(5), t2p5(6), t3p0(7), t-0p5(8), t-1p0(9), t-1p5(10), t-2p0(11), t-2p5(12), t-3p0(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Offset of temperature in degree C to adjust EMD temperature measurement." ::= { ipmEnvEmdConfigTemp 6 } ipmEnvEmdConfigHumi OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 4 } -- =========================================================================== -- -- ipmEnvEmdConfigHumi -- -- Environmental Monitor Device Humidity Configuration Group -- -- =========================================================================== ipmEnvEmdConfigHumiName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Humidity." ::= { ipmEnvEmdConfigHumi 1 } ipmEnvEmdConfigHumiHighSetPoint OBJECT-TYPE SYNTAX INTEGER (5..95) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD humidity set point high, alarm will active when humidity over this value, in %." ::= { ipmEnvEmdConfigHumi 2 } ipmEnvEmdConfigHumiHighStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipmEnvEmdConfigHumi 3 } ipmEnvEmdConfigHumiLowSetPoint OBJECT-TYPE SYNTAX INTEGER (5..95) -- ACCESS read-write STATUS mandatory DESCRIPTION "EMD humidity set point low, alarm will active when humidity under this value, in %." ::= { ipmEnvEmdConfigHumi 4 } ipmEnvEmdConfigHumiLowStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled the high setpoint be applied or not" ::= { ipmEnvEmdConfigHumi 5 } ipmEnvEmdConfigHumiOffset OBJECT-TYPE SYNTAX INTEGER { h0p0(1), h1p0(2), h2p0(3), h3p0(4), h4p0(5), h5p0(6), h6p0(7), h-1p0(8), h-2p0(9), h-3p0(10), h-4p0(11), h-5p0(12), h-6p0(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Emd Hum Offset;" ::= { ipmEnvEmdConfigHumi 6 } ipmEnvEmdConfigAlarm1 OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 5 } -- =========================================================================== -- -- ipmEnvEmdConfigAlarm1 -- -- Environmental Monitor Device Alarm-1 Configuration Group -- -- =========================================================================== ipmEnvEmdConfigAlarm1Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Alarm-1." ::= { ipmEnvEmdConfigAlarm1 1 } ipmEnvEmdConfigAlarm1Type OBJECT-TYPE SYNTAX INTEGER { disabled(1), normalOpen(2), normalClose(3) } ACCESS read-write STATUS mandatory DESCRIPTION "EMD Alarm-1 type" ::= { ipmEnvEmdConfigAlarm1 2 } ipmEnvEmdConfigAlarm2 OBJECT IDENTIFIER ::= { ipmEnvEmdConfig 6 } -- =========================================================================== -- -- ipmEnvEmdConfigAlarm2 -- -- Environmental Monitor Device Alarm-2 Configuration Group -- -- =========================================================================== ipmEnvEmdConfigAlarm2Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of EMD Alarm-2." ::= { ipmEnvEmdConfigAlarm2 1 } ipmEnvEmdConfigAlarm2Type OBJECT-TYPE SYNTAX INTEGER { disabled(1), normalOpen(2), normalClose(3) } ACCESS read-write STATUS mandatory DESCRIPTION "EMD Alarm-2 type" ::= { ipmEnvEmdConfigAlarm2 2 } -- =========================================================================== -- ipmTraps -- -- iPoManII Trap group -- =========================================================================== -- This section defines the well-known notifications sent by -- iPoManII agents. ipmInletVoltageTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input voltage over high threshold." ::= 1 ipmInletVoltageNotTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageHigh, inletConfigDesc } DESCRIPTION "WARNING: The input voltage return from over high threshold." ::= 2 ipmInletVoltageTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input voltage under low threshold." ::= 3 ipmInletVoltageNotTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusVoltage, inletConfigVoltageLow, inletConfigDesc } DESCRIPTION "WARNING: The input voltage return from under low threshold." ::= 4 ipmInletCurrentTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input current over high threshold." ::= 5 ipmInletCurrentNotTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusCurrent, inletConfigCurrentHigh, inletConfigDesc } DESCRIPTION "WARNING: The input current return from over high threshold." ::= 6 ipmInletFrequencyTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "CRITICAL: The input frequency over high threshold." ::= 7 ipmInletFrequencyNotTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyHigh, inletConfigDesc } DESCRIPTION "WARNING: The input frequency return from over high threshold." ::= 8 ipmInletFrequencyTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "CRITICAL: The input frequency under low threshold." ::= 9 ipmInletFrequencyNotTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { inletConfigIndex, inletStatusFrequency, inletConfigFrequencyLow, inletConfigDesc } DESCRIPTION "WARNING: The input frequency return from under low threshold." ::= 10 ipmOutletCurrentTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { outletConfigIndex, outletStatusCurrent, outletConfigCurrentHigh, outletConfigDesc } DESCRIPTION "CRITICAL: The output current of outlet over high threshold." ::= 11 ipmOutletCurrentNotTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { outletConfigIndex, outletStatusCurrent, outletConfigCurrentHigh, outletConfigDesc } DESCRIPTION "WARNING: The output current of outlet return from over high threshold." ::= 12 ipmOutletStateChanged TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { outletConfigIndex, outletStatusStatus, outletConfigDesc } DESCRIPTION "INFORMATION: The outlet state had changed from on to off, or from off to on." ::= 13 ipmEmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusTemperature, ipmEnvEmdConfigTempHighSetPoint, ipmEnvEmdConfigTempName } DESCRIPTION "INFORMATION: emd Temperature Not High." ::= 14 ipmEmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusTemperature, ipmEnvEmdConfigTempHighSetPoint, ipmEnvEmdConfigTempName } DESCRIPTION "WARNING: emd Temperature Too High." ::= 15 ipmEmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusTemperature, ipmEnvEmdConfigTempLowSetPoint, ipmEnvEmdConfigTempName } DESCRIPTION "INFORMATION: emd Temperature Not Low." ::= 16 ipmEmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusTemperature, ipmEnvEmdConfigTempLowSetPoint, ipmEnvEmdConfigTempName } DESCRIPTION "WARNING: emd Temperature Too Low." ::= 17 ipmEmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusHumidity, ipmEnvEmdConfigHumiHighSetPoint, ipmEnvEmdConfigHumiName } DESCRIPTION "INFORMATION: emd Humidity Not High." ::= 18 ipmEmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusHumidity, ipmEnvEmdConfigHumiHighSetPoint, ipmEnvEmdConfigHumiName } DESCRIPTION "WARNING: emd Humidity Too High." ::= 19 ipmEmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusHumidity, ipmEnvEmdConfigHumiLowSetPoint, ipmEnvEmdConfigHumiName } DESCRIPTION "INFORMATION: emd Humidity Not Low." ::= 20 ipmEmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdStatusHumidity, ipmEnvEmdConfigHumiLowSetPoint, ipmEnvEmdConfigHumiName } DESCRIPTION "WARNING: emd Humidity Too Low." ::= 21 ipmEmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdConfigAlarm1Type, ipmEnvEmdConfigAlarm1Name } DESCRIPTION "INFORMATION: emd Alarm1 Normal." ::= 22 ipmEmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdConfigAlarm1Type, ipmEnvEmdConfigAlarm1Name } DESCRIPTION "WARNING: emd Alarm1 Active." ::= 23 ipmEmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdConfigAlarm2Type, ipmEnvEmdConfigAlarm2Name } DESCRIPTION "INFORMATION: emd Alarm2 Normal." ::= 24 ipmEmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps VARIABLES { ipmEnvEmdConfigAlarm2Type, ipmEnvEmdConfigAlarm2Name } DESCRIPTION "WARNING: emd Alarm2 Active." ::= 25 ipmSlave01Inlet01OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage over high threshold." ::= 26 ipmSlave01Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage Not over high threshold." ::= 27 ipmSlave01Inlet02OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage over high threshold." ::= 28 ipmSlave01Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage Not over high threshold." ::= 29 ipmSlave01Inlet01UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage under low threshold." ::= 30 ipmSlave01Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 voltage Not under low threshold." ::= 31 ipmSlave01Inlet02UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage under low threshold." ::= 32 ipmSlave01Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 voltage Not under low threshold." ::= 33 ipmSlave01Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 current over high threshold." ::= 34 ipmSlave01Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input01 current not over high threshold." ::= 35 ipmSlave01Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 current over high threshold." ::= 36 ipmSlave01Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave01 input02 current not over high threshold." ::= 37 ipmSlave01EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Temperature Not High." ::= 38 ipmSlave01EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Temperature Too High." ::= 39 ipmSlave01EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Temperature Not Low." ::= 40 ipmSlave01EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Temperature Too Low." ::= 41 ipmSlave01EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Humidity Not High." ::= 42 ipmSlave01EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Humidity Too High." ::= 43 ipmSlave01EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Humidity Not Low." ::= 44 ipmSlave01EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Humidity Too Low." ::= 45 ipmSlave01EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Alarm1 Normal." ::= 46 ipmSlave01EmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Alarm1 Active." ::= 47 ipmSlave01EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave01 emd Alarm2 Normal." ::= 48 ipmSlave01EmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 emd Alarm2 Active." ::= 49 ipmSlave01OutletCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave01 Outlet Current over threshold." ::= 50 ipmSlave02Inlet01OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage over high threshold." ::= 51 ipmSlave02Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage Not over high threshold." ::= 52 ipmSlave02Inlet02OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage over high threshold." ::= 53 ipmSlave02Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage Not over high threshold." ::= 54 ipmSlave02Inlet01UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage under low threshold." ::= 55 ipmSlave02Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 voltage Not under low threshold." ::= 56 ipmSlave02Inlet02UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage under low threshold." ::= 57 ipmSlave02Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 voltage Not under low threshold." ::= 58 ipmSlave02Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 current over high threshold." ::= 59 ipmSlave02Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input01 current not over high threshold." ::= 60 ipmSlave02Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 current over high threshold." ::= 61 ipmSlave02Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave02 input02 current not over high threshold." ::= 62 ipmSlave02EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Temperature Not High." ::= 63 ipmSlave02EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Temperature Too High." ::= 64 ipmSlave02EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Temperature Not Low." ::= 65 ipmSlave02EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Temperature Too Low." ::= 66 ipmSlave02EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Humidity Not High." ::= 67 ipmSlave02EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Humidity Too High." ::= 68 ipmSlave02EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Humidity Not Low." ::= 69 ipmSlave02EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Humidity Too Low." ::= 70 ipmSlave02EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Alarm1 Normal." ::= 71 ipmSlave02EmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Alarm1 Active." ::= 72 ipmSlave02EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave02 emd Alarm2 Normal." ::= 73 ipmSlave02EmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 emd Alarm2 Active." ::= 74 ipmSlave02OutletCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave02 Outlet Current over threshold." ::= 75 ipmSlave03Inlet01OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage over high threshold." ::= 76 ipmSlave03Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage Not over high threshold." ::= 77 ipmSlave03Inlet02OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage over high threshold." ::= 78 ipmSlave03Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage Not over high threshold." ::= 79 ipmSlave03Inlet01UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage under low threshold." ::= 80 ipmSlave03Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 voltage Not under low threshold." ::= 81 ipmSlave03Inlet02UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage under low threshold." ::= 82 ipmSlave03Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 voltage Not under low threshold." ::= 83 ipmSlave03Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 current over high threshold." ::= 84 ipmSlave03Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input01 current not over high threshold." ::= 85 ipmSlave03Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 current over high threshold." ::= 86 ipmSlave03Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave03 input02 current not over high threshold." ::= 87 ipmSlave03EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Temperature Not High." ::= 88 ipmSlave03EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Temperature Too High." ::= 89 ipmSlave03EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Temperature Not Low." ::= 90 ipmSlave03EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Temperature Too Low." ::= 91 ipmSlave03EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Humidity Not High." ::= 92 ipmSlave03EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Humidity Too High." ::= 93 ipmSlave03EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Humidity Not Low." ::= 94 ipmSlave03EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Humidity Too Low." ::= 95 ipmSlave03EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Alarm1 Normal." ::= 96 ipmSlave03EmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Alarm1 Active." ::= 97 ipmSlave03EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave03 emd Alarm2 Normal." ::= 98 ipmSlave03EmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 emd Alarm2 Active." ::= 99 ipmSlave03OutletCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave03 Outlet Current over threshold." ::= 100 ipmSlave04Inlet01OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage over high threshold." ::= 101 ipmSlave04Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage Not over high threshold." ::= 102 ipmSlave04Inlet02OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage over high threshold." ::= 103 ipmSlave04Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage Not over high threshold." ::= 104 ipmSlave04Inlet01UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage under low threshold." ::= 105 ipmSlave04Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 voltage Not under low threshold." ::= 106 ipmSlave04Inlet02UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage under low threshold." ::= 107 ipmSlave04Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 voltage Not under low threshold." ::= 108 ipmSlave04Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 current over high threshold." ::= 109 ipmSlave04Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input01 current not over high threshold." ::= 110 ipmSlave04Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 current over high threshold." ::= 111 ipmSlave04Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave04 input02 current not over high threshold." ::= 112 ipmSlave04EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Temperature Not High." ::= 113 ipmSlave04EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Temperature Too High." ::= 114 ipmSlave04EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Temperature Not Low." ::= 115 ipmSlave04EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Temperature Too Low." ::= 116 ipmSlave04EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Humidity Not High." ::= 117 ipmSlave04EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Humidity Too High." ::= 118 ipmSlave04EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Humidity Not Low." ::= 119 ipmSlave04EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Humidity Too Low." ::= 120 ipmSlave04EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Alarm1 Normal." ::= 121 ipmSlave04EmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Alarm1 Active." ::= 122 ipmSlave04EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave04 emd Alarm2 Normal." ::= 123 ipmSlave04EmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 emd Alarm2 Active." ::= 124 ipmSlave04OutletCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave04 Outlet Current over threshold." ::= 125 ipmSlave05Inlet01OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage over high threshold." ::= 126 ipmSlave05Inlet01NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage Not over high threshold." ::= 127 ipmSlave05Inlet02OverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage over high threshold." ::= 128 ipmSlave05Inlet02NotOverHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage Not over high threshold." ::= 129 ipmSlave05Inlet01UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage under low threshold." ::= 130 ipmSlave05Inlet01NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 voltage Not under low threshold." ::= 131 ipmSlave05Inlet02UnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage under low threshold." ::= 132 ipmSlave05Inlet02NotUnderLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 voltage Not under low threshold." ::= 133 ipmSlave05Inlet01CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 current over high threshold." ::= 134 ipmSlave05Inlet01NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input01 current not over high threshold." ::= 135 ipmSlave05Inlet02CurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 current over high threshold." ::= 136 ipmSlave05Inlet02NotCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "CRITICAL: The Slave05 input02 current not over high threshold." ::= 137 ipmSlave05EmdTemperatureNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Temperature Not High." ::= 138 ipmSlave05EmdTemperatureTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Temperature Too High." ::= 139 ipmSlave05EmdTemperatureNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Temperature Not Low." ::= 140 ipmSlave05EmdTemperatureTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Temperature Too Low." ::= 141 ipmSlave05EmdHumidityNotHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Humidity Not High." ::= 142 ipmSlave05EmdHumidityTooHigh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Humidity Too High." ::= 143 ipmSlave05EmdHumidityNotLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Humidity Not Low." ::= 144 ipmSlave05EmdHumidityTooLow TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Humidity Too Low." ::= 145 ipmSlave05EmdAlarm1Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Alarm1 Normal." ::= 146 ipmSlave05EmdAlarm1Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Alarm1 Active." ::= 147 ipmSlave05EmdAlarm2Normal TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "INFORMATION: The Slave05 emd Alarm2 Normal." ::= 148 ipmSlave05EmdAlarm2Active TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 emd Alarm2 Active." ::= 149 ipmSlave05OutletCurrentOverTh TRAP-TYPE ENTERPRISE ipmTraps DESCRIPTION "WARNING: The Slave05 Outlet Current over threshold." ::= 150 END