-- ***************************************************************************** -- Juniper-DS1-MIB -- -- Juniper Networks Enterprise MIB -- DS1/E1 MIB -- -- Copyright (c) 1998, 1999 Redstone Communications, Inc. -- Copyright (c) 1999, 2002 Unisphere Networks, Inc. -- Copyright (c) 2002, 2003 Juniper Networks, Inc. -- All Rights Reserved. -- ***************************************************************************** Juniper-DS1-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI RowStatus, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex, InterfaceIndexOrZero FROM IF-MIB juniMibs FROM Juniper-MIBs JuniTimeSlotMap, JuniNextIfIndex FROM Juniper-TC; juniDs1MIB MODULE-IDENTITY LAST-UPDATED "200302101507Z" -- 10-Feb-03 10:07 AM EST ORGANIZATION "Juniper Networks, Inc." CONTACT-INFO " Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net" DESCRIPTION "The DS1/E1 MIB for the Juniper enterprise. This MIB contains managed objects to supplement those found in RFC1406 DS1/E1 MIB." -- Revision History REVISION "200302101507Z" -- 10-Feb-03 10:07 AM EST - JUNOSe 5.0 DESCRIPTION "Replaced Unisphere names with Juniper names." REVISION "200209121659Z" -- 12-Sep-02 12:59 PM EDT - JUNOSe 4.1 DESCRIPTION "Added support for FDL transmit mode, remote FDL strings and far end FDL carrier." REVISION "200205131601Z" -- 13-May-02 12:01 PM EDT - JUNOSe 4.0 DESCRIPTION "Added support for FDL." REVISION "200107311825Z" -- 31-Jul-01 02:25 PM EDT - JUNOSe 3.2 DESCRIPTION "Change access on juniDsx1Ds1ChannelNumber." REVISION "200104041805Z" -- 04-Apr-01 02:05 PM EDT - JUNOSe 3.0 DESCRIPTION "Added dynamic DS1 interface support." REVISION "9906170000Z" -- 17-Jun-99 - JUNOSe 1.1 DESCRIPTION "Updated version of this MIB module." REVISION "9811130000Z" -- 13-Nov-98 - JUNOSe 1.0 DESCRIPTION "Initial version of this MIB module." ::= { juniMibs 5 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Managed objects -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ juniDs1Objects OBJECT IDENTIFIER ::= { juniDs1MIB 1 } -- ///////////////////////////////////////////////////////////////////////////// -- -- DS1 Interfaces -- -- ///////////////////////////////////////////////////////////////////////////// -- -- The DS1 Configuration Table -- juniDsx1ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF JuniDsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for DS1/E1 interfaces present in the system." ::= { juniDs1Objects 1 } juniDsx1ConfigEntry OBJECT-TYPE SYNTAX JuniDsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describes the characteristics of an DS1/E1 interface." INDEX { ifIndex } ::= { juniDsx1ConfigTable 1 } JuniDsx1ConfigEntry ::= SEQUENCE { juniDsx1TimeSlotMap JuniTimeSlotMap, juniDsx1Ds1ChannelNumber Integer32, juniDsx1Capabilities Integer32, juniDsx1Mode INTEGER, juniDsx1LineBuildOutCapabilities Integer32, juniDsx1LineBuildOutType INTEGER, juniDsx1LineAttenuation INTEGER, juniDsx1LineLength Integer32, juniDsx1LowerIfIndex InterfaceIndexOrZero, juniDsx1RowStatus RowStatus, juniDsx1SendCode INTEGER, juniDsx1YellowAlarm INTEGER, juniDsx1RemoteLoopback INTEGER, juniDsx1FdlCarrier INTEGER, juniDsx1FdlEic DisplayString, juniDsx1FdlLic DisplayString, juniDsx1FdlFic DisplayString, juniDsx1FdlUnit DisplayString, juniDsx1FdlPfi DisplayString, juniDsx1FdlPort DisplayString, juniDsx1FdlGenerator DisplayString, juniDsx1FdlTransmit BITS } juniDsx1TimeSlotMap OBJECT-TYPE SYNTAX JuniTimeSlotMap MAX-ACCESS read-only STATUS current DESCRIPTION "A bitmap representing the timeslots on the DS1/E1 interface that have been allocated for service. For channelized DS1/E1, set bits reflect the union of timeslot allocations across all fractional arrangements operating over this DS1/E1 interface. For unchannelized DS1/E1, all relevant timeslot bits will be set." ::= { juniDsx1ConfigEntry 1 } juniDsx1Ds1ChannelNumber OBJECT-TYPE SYNTAX Integer32 (0..28) MAX-ACCESS read-create STATUS current DESCRIPTION "This variable represents the channel number of the DS1/E1 on its parent DS3/E3. A value of 0 indicates this DS1/E1 does not have a parent DS3/E3." ::= { juniDsx1ConfigEntry 2 } juniDsx1Capabilities OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "A value which indicates the set of capabilities of the DS1/E1 interface. The value is a sum. This sum initially takes the value zero. Then, for each capability, C, in the range 1 through 3, that this interface supports, 2 raised to (C - 1) is added to the sum. For example, an interface which is only E1 capable would have a value of 2 (2^(2-1)). In contrast, an interface which is both T1 and J1 capable would have a value of 5 (2^(1-1) + 2^(3-1)). The values for DS1/E1 interface capabilities are as follows: capability function 1 T1 2 E1 3 J1 " ::= { juniDsx1ConfigEntry 3 } juniDsx1Mode OBJECT-TYPE SYNTAX INTEGER { t1(1), e1(2), j1(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable represents the DS1/E1 interface mode. The value of the juniDsx1Capabilities object for the DS1/E1 interface indicates the valid set of values for this object." ::= { juniDsx1ConfigEntry 4 } juniDsx1LineBuildOutCapabilities OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "A value which indicates the set of line build out capabilities of the DS1/E1 interface. The value is a sum. This sum initially takes the value zero. Then, for each line build out capability, C, in the range 1 or 2, that this interface supports, 2 raised to (C - 1) is added to the sum. For example, an interface which is only short haul capable would have a value of 2 (2^(2-1)). In contrast, an interface which is both short haul and long haul capable would have a value of 3 (2^(1-1) + 2^(2-1)). The values for DS1/E1 interface line build out capabilities are as follows: line build out capability function 1 short haul 2 long haul" ::= { juniDsx1ConfigEntry 5 } juniDsx1LineBuildOutType OBJECT-TYPE SYNTAX INTEGER { shortHaul(1), longHaul(2), notSupported(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable represents the configured line build out type of the DS1/E1 interface. The value of the juniDsx1LineBuildOutCapabilities object for the DS1/E1 interface indicates the valid set of values for this object." ::= { juniDsx1ConfigEntry 6 } juniDsx1LineAttenuation OBJECT-TYPE SYNTAX INTEGER { db0(1), dbMinus7Point5(2), dbMinus15(3), dbMinus22Point5(4), notSupported(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable represents the configured line attenuation of the DS1/E1 interface. Note that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to longHaul(2)." ::= { juniDsx1ConfigEntry 7 } juniDsx1LineLength OBJECT-TYPE SYNTAX Integer32 (0..64000) UNITS "meters" MAX-ACCESS read-create STATUS current DESCRIPTION "This variable represents the length of the DS1/E1 line in meters. Note that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to shortHaul(1)." ::= { juniDsx1ConfigEntry 8 } juniDsx1LowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex of the interface over which this Dsx1 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation." ::= { juniDsx1ConfigEntry 9 } juniDsx1RowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniDsx1RowStatus juniDsx1LowerIfIndex In addition, when creating an entry the following conditions must hold: A value for ifIndex must have been determined previously, by reading juniDsx1NextIfIndex. The interface identified by juniDsx1hLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table." ::= { juniDsx1ConfigEntry 10 } juniDsx1SendCode OBJECT-TYPE SYNTAX INTEGER { sendInbandLineCode(1), sendBellcoreLineCode(2), sendBellcoreInbandLineCode(3), sendQRSPattern(4), sendAllZerosPattern(5), sendAllOnesPattern(6), sendAltZeroOnePattern(7), sendTwo11Pattern(8), sendTwo15Pattern(9), sendTwo20Pattern(10), sendTwo23Pattern(11), sendUnfrQRSPattern(12), sendUnfrAllZerosPattern(13), sendUnfrAllOnesPattern(14), sendUnfrAltZeroOnePattern(15), sendUnfrTwo11Pattern(16), sendUnfrTwo15Pattern(17), sendUnfrTwo20Pattern(18), sendUnfrTwo23Pattern(19), otherPattern(20) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS1 interface by the device." DEFVAL { otherPattern } ::= { juniDsx1ConfigEntry 11 } juniDsx1YellowAlarm OBJECT-TYPE SYNTAX INTEGER { generate(1), detect(2), generateAndDetect(3), none(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This bitmap indicates the yellow alarm settings, and is the sum of the capabilities." ::= { juniDsx1ConfigEntry 12 } juniDsx1RemoteLoopback OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable indicates the remote loopback setting." DEFVAL { disabled } ::= { juniDsx1ConfigEntry 13 } juniDsx1FdlCarrier OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the interface is used in carrier environment." DEFVAL { disabled } ::= { juniDsx1ConfigEntry 14 } juniDsx1FdlEic OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the equipment identification code." DEFVAL { "" } ::= { juniDsx1ConfigEntry 15 } juniDsx1FdlLic OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the location identification code." DEFVAL { "" } ::= { juniDsx1ConfigEntry 16 } juniDsx1FdlFic OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the frame identification code." DEFVAL { "" } ::= { juniDsx1ConfigEntry 17 } juniDsx1FdlUnit OBJECT-TYPE SYNTAX DisplayString (SIZE(0..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the unit identification code." DEFVAL { "" } ::= { juniDsx1ConfigEntry 18 } juniDsx1FdlPfi OBJECT-TYPE SYNTAX DisplayString (SIZE(0..38)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the facility identification code." DEFVAL { "" } ::= { juniDsx1ConfigEntry 19 } juniDsx1FdlPort OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the equipment port number." ::= { juniDsx1ConfigEntry 20 } juniDsx1FdlGenerator OBJECT-TYPE SYNTAX DisplayString (SIZE(0..38)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the generator number." ::= { juniDsx1ConfigEntry 21 } juniDsx1FdlTransmit OBJECT-TYPE SYNTAX BITS { path(0), idlesignal(1), testsignal(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies transmission enabling. path - Bit 0 for path transmit. When this bit is set indicates path transmit is enabled; otherwise path transmit disabled. idlesignal - Bit 1 for idlesignal transmit. When this bit is set idlesingal transmit is enabled; otherwise idlesignal transmit disabled. testsignal - Bit 2 for testsignal transmit. When this bit is set testsignal transmit is enabled; otherwise testsignal transmit disabled. The value of this object defaults to zero, indicating that none of FDL transmit methods are enabled." DEFVAL { { } } ::= { juniDsx1ConfigEntry 22 } juniDs1NextIfIndex OBJECT-TYPE SYNTAX JuniNextIfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Coordinate ifIndex value allocation for entries in juniDsx1ConfigTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously." ::= { juniDs1Objects 2 } -- -- The DS1 Far End Configuration Table contains -- configuration information reported from the remote end. -- juniDsx1FarEndConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF JuniDsx1FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Far End Configuration table." ::= { juniDs1Objects 3 } juniDsx1FarEndConfigEntry OBJECT-TYPE SYNTAX JuniDsx1FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Far End Configuration table." INDEX { juniDsx1FarEndLineIndex } ::= { juniDsx1FarEndConfigTable 1 } JuniDsx1FarEndConfigEntry ::= SEQUENCE { juniDsx1FarEndLineIndex INTEGER, juniDsx1FarEndEquipCode DisplayString, juniDsx1FarEndLocationIDCode DisplayString, juniDsx1FarEndFrameIDCode DisplayString, juniDsx1FarEndUnitCode DisplayString, juniDsx1FarEndFacilityIDCode DisplayString, juniDsx1FarEndPortNumber DisplayString, juniDsx1FarEndGeneratorNumber DisplayString, juniDsx1FarEndCarrier INTEGER } juniDsx1FarEndLineIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index value which uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value a dsx1LineIndex object instance." ::= { juniDsx1FarEndConfigEntry 1 } juniDsx1FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message." ::= { juniDsx1FarEndConfigEntry 2 } juniDsx1FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message." ::= { juniDsx1FarEndConfigEntry 3 } juniDsx1FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message." ::= { juniDsx1FarEndConfigEntry 4 } juniDsx1FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message." ::= { juniDsx1FarEndConfigEntry 5 } juniDsx1FarEndFacilityIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-only STATUS current DESCRIPTION "This code identifies a specific Far End DS1 path. It is sent within the Path Identification Message." ::= { juniDsx1FarEndConfigEntry 6 } juniDsx1FarEndPortNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This code identifies the port number of the Far End DS1. It is sent within the Idle Signal Message." ::= { juniDsx1FarEndConfigEntry 7 } juniDsx1FarEndGeneratorNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-only STATUS current DESCRIPTION "This code identifies the Far End DS1 Generator Number. It is sent within the Test Signal Message." ::= { juniDsx1FarEndConfigEntry 8 } juniDsx1FarEndCarrier OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the interface is used in carrier environment. It is sent with all FDL messages." ::= { juniDsx1FarEndConfigEntry 9 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Notifications -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- No notifications are defined in this MIB. Placeholders follow. -- juniDs1TrapControl OBJECT IDENTIFIER ::= { juniDs1MIB 2 } -- juniDs1Traps OBJECT IDENTIFIER ::= { juniDs1MIB 3 } -- juniDs1TrapPrefix OBJECT IDENTIFIER ::= { juniDs1Traps 0 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Conformance information -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ juniDs1Conformance OBJECT IDENTIFIER ::= { juniDs1MIB 4 } juniDs1Compliances OBJECT IDENTIFIER ::= { juniDs1Conformance 1 } juniDs1Groups OBJECT IDENTIFIER ::= { juniDs1Conformance 2 } -- -- compliance statements -- juniDs1Compliance MODULE-COMPLIANCE STATUS obsolete DESCRIPTION "Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when new objects were added." MODULE -- this module MANDATORY-GROUPS { juniDs1Group } ::= { juniDs1Compliances 1 } -- JUNOSe 1.0 juniDs1Compliance2 MODULE-COMPLIANCE STATUS obsolete DESCRIPTION "Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when dynamic DS1 interface support was added." MODULE -- this module MANDATORY-GROUPS { juniDs1Group2 } ::= { juniDs1Compliances 2 } -- JUNOSe 1.1 juniDs1Compliance3 MODULE-COMPLIANCE STATUS obsolete DESCRIPTION "Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when FDL support was added." MODULE -- this module MANDATORY-GROUPS { juniDs1Group3 } ::= { juniDs1Compliances 3 } -- JUNOSe 3.0 juniDs1Compliance4 MODULE-COMPLIANCE STATUS obsolete DESCRIPTION "Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when support for remote FDL strings and FDL transmit mode was added." MODULE -- this module MANDATORY-GROUPS { juniDs1Group4 } ::= { juniDs1Compliances 4 } -- JUNOSe 4.0 juniDs1Compliance5 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Juniper DS1/E1 MIB." MODULE -- this module MANDATORY-GROUPS { juniDs1Group5 } ::= { juniDs1Compliances 5 } -- JUNOSe 4.1 -- -- units of conformance -- juniDs1Group OBJECT-GROUP OBJECTS { juniDsx1TimeSlotMap, juniDsx1Ds1ChannelNumber } STATUS obsolete DESCRIPTION "Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when new objects where added to the MIB." ::= { juniDs1Groups 1 } juniDs1Group2 OBJECT-GROUP OBJECTS { juniDsx1TimeSlotMap, juniDsx1Ds1ChannelNumber, juniDsx1Capabilities, juniDsx1Mode, juniDsx1LineBuildOutCapabilities, juniDsx1LineBuildOutType, juniDsx1LineAttenuation, juniDsx1LineLength } STATUS obsolete DESCRIPTION "Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when dynamic DS1 interface support was added." ::= { juniDs1Groups 2 } juniDs1Group3 OBJECT-GROUP OBJECTS { juniDsx1TimeSlotMap, juniDsx1Ds1ChannelNumber, juniDsx1Capabilities, juniDsx1Mode, juniDsx1LineBuildOutCapabilities, juniDsx1LineBuildOutType, juniDsx1LineAttenuation, juniDsx1LineLength, juniDsx1LowerIfIndex, juniDsx1RowStatus, juniDs1NextIfIndex } STATUS obsolete DESCRIPTION "Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when FDL support was added." ::= { juniDs1Groups 3 } juniDs1Group4 OBJECT-GROUP OBJECTS { juniDsx1TimeSlotMap, juniDsx1Ds1ChannelNumber, juniDsx1Capabilities, juniDsx1Mode, juniDsx1LineBuildOutCapabilities, juniDsx1LineBuildOutType, juniDsx1LineAttenuation, juniDsx1LineLength, juniDsx1LowerIfIndex, juniDsx1RowStatus, juniDsx1SendCode, juniDsx1YellowAlarm, juniDsx1RemoteLoopback, juniDsx1FdlCarrier, juniDsx1FdlEic, juniDsx1FdlLic, juniDsx1FdlFic, juniDsx1FdlUnit, juniDsx1FdlPfi, juniDsx1FdlPort, juniDsx1FdlGenerator, juniDs1NextIfIndex } STATUS obsolete DESCRIPTION "Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when support for remote FDL strings and FDL transmit mode was added." ::= { juniDs1Groups 4 } juniDs1Group5 OBJECT-GROUP OBJECTS { juniDsx1TimeSlotMap, juniDsx1Ds1ChannelNumber, juniDsx1Capabilities, juniDsx1Mode, juniDsx1LineBuildOutCapabilities, juniDsx1LineBuildOutType, juniDsx1LineAttenuation, juniDsx1LineLength, juniDsx1LowerIfIndex, juniDsx1RowStatus, juniDsx1SendCode, juniDsx1YellowAlarm, juniDsx1RemoteLoopback, juniDsx1FdlCarrier, juniDsx1FdlEic, juniDsx1FdlLic, juniDsx1FdlFic, juniDsx1FdlUnit, juniDsx1FdlPfi, juniDsx1FdlPort, juniDsx1FdlGenerator, juniDsx1FdlTransmit, juniDsx1FarEndEquipCode, juniDsx1FarEndLocationIDCode, juniDsx1FarEndFrameIDCode, juniDsx1FarEndUnitCode, juniDsx1FarEndFacilityIDCode, juniDsx1FarEndPortNumber, juniDsx1FarEndGeneratorNumber, juniDsx1FarEndCarrier, juniDs1NextIfIndex } STATUS current DESCRIPTION "A collection of objects providing management of DS1/E1 interfaces in a Juniper product." ::= { juniDs1Groups 5 } END