-- ***************************************************************************** -- Juniper-ES2-Registry -- -- Juniper Networks enterprise SNMP MIB. -- Registry for the second generation E-series edge router product entities. -- -- Copyright (c) 2003-2008 Juniper Networks, Inc. -- All Rights Reserved. -- ***************************************************************************** Juniper-ES2-Registry DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY FROM SNMPv2-SMI juniAdmin FROM Juniper-Registry; juniES2Registry MODULE-IDENTITY LAST-UPDATED "200805081148Z" -- 08-May-08 07:48 AM EDT ORGANIZATION "Juniper Networks, Inc." CONTACT-INFO " Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net" DESCRIPTION "Juniper second generation E-series product family system-specific object identification values. This module defines AutonomousType (OID) values for all the physical entity types (entPhysicalVendorType). This module will be updated whenever a new type of module or other hardware becomes available in second generation E-series systems." -- Revision History REVISION "200805081148Z" -- 08-May-08 07:48 AM EDT - JUNOSe 10.0 DESCRIPTION "Added es2Lm10s support." REVISION "200612182106Z" -- 18-Dec-06 04:06 PM EST - JUNOSe 8.3 DESCRIPTION "Added GE20 IOA Support." REVISION "200611240913Z" -- 24-Nov-06 04:13 AM EST - JUNOSe 8.2 DESCRIPTION "Added E120 product family support." REVISION "200601061806Z" -- 06-Jan-06 01:06 PM EST - JUNOSe main DESCRIPTION "Added LM10 Access Support." REVISION "200509151346Z" -- 15-Sep-05 09:46 AM EDT - JUNOSe 7.2 DESCRIPTION "Added LM10 Uplink Support." REVISION "200508191158Z" -- 19-Aug-05 06:58 AM EST - JUNOSe main DESCRIPTION "Added GE8 Support." REVISION "200507291826Z" -- 29-Jul-05 02:26 PM EDT - JUNOSe 7.0.1 DESCRIPTION "renamed entity objects, reordered to match rsSystem.mi2 and removed obsoleted boards." REVISION "200412231158Z" -- 23-Dec-04 06:58 AM EST - JUNOSe main DESCRIPTION "Updated for second generation E-series hardware." REVISION "200412061021Z" -- 06-Dec-04 05:21 AM EDT - JUNOSe main DESCRIPTION "Renamed E2 MIB objects to ES2 MIB objects." REVISION "200405191742Z" -- 19-May-04 01:42 PM EDT - JUNOSe 6.0 DESCRIPTION "Updated for revised E320 hardware." REVISION "200308182027Z" -- 18-Aug-03 04:27 PM EDT - JUNOSe 6.0 DESCRIPTION "Initial version of this SNMP management information module." ::= { juniAdmin 3 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Second generation E-series physical entity identifiers. -- The OID values under juniES2EntPhysicalType are used by the SNMP agent in -- the second generation E-series product as the AutonomousType values for the -- entPhysicalVendorType varbinds for the second generation E-series objects in -- the entPhysicalTable. -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ juniES2EntPhysicalType OBJECT IDENTIFIER ::= { juniES2Registry 1 } -- -- Chassis class -- es2Chassis OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series chassis. This identifies an 'overall' physical entity for any second generation E-series system." ::= { juniES2EntPhysicalType 1 } e320BaseChassis OBJECT-IDENTITY STATUS current DESCRIPTION "E320 base chassis with 12 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E320 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA)." ::= { es2Chassis 1 } e120BaseChassis OBJECT-IDENTITY STATUS current DESCRIPTION "E120 base chassis with 6 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E120 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA)." ::= { es2Chassis 2 } -- -- Fan class -- es2FanAssembly OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series fan assembly." ::= { juniES2EntPhysicalType 2 } e320PrimaryFanTray OBJECT-IDENTITY STATUS current DESCRIPTION "E320 fan tray with 8 fans." ::= { es2FanAssembly 1 } e320AuxiliaryFanTray OBJECT-IDENTITY STATUS current DESCRIPTION "E320 fan tray with 8 fans." ::= { es2FanAssembly 2 } e120PrimaryFanTray OBJECT-IDENTITY STATUS current DESCRIPTION "E120 fan tray with 9 fans." ::= { es2FanAssembly 3 } -- -- Power Supply class -- es2PowerInput OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series power distribution module." ::= { juniES2EntPhysicalType 3 } e320DcPowerDistributionUnit OBJECT-IDENTITY STATUS current DESCRIPTION "E320 DC power distribution unit (PDU)." ::= { es2PowerInput 1 } -- -- Backplane class -- es2Midplane OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series midplane." ::= { juniES2EntPhysicalType 4 } e320Midplane OBJECT-IDENTITY STATUS current DESCRIPTION "E320 chassis midplane." ::= { es2Midplane 1 } e120Midplane OBJECT-IDENTITY STATUS current DESCRIPTION "E120 chassis midplane." ::= { es2Midplane 2 } -- -- Module class - integrated system controller/switch fabric -- es2SrpModule OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series system controller/ switch fabric module." ::= { juniES2EntPhysicalType 5 } e320Srp100 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 100Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding." ::= { es2SrpModule 1 } e320Srp320 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 320Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding." ::= { es2SrpModule 2 } e120Srp120 OBJECT-IDENTITY STATUS current DESCRIPTION "E120 120Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding." ::= { es2SrpModule 3 } -- -- Module class - switch fabric -- es2SwitchFabricModule OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series switch fabric module." ::= { juniES2EntPhysicalType 6 } e320Sfm100 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 100Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing." ::= { es2SwitchFabricModule 1 } e320Sfm320 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 320Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing." ::= { es2SwitchFabricModule 2 } e120Sfm120 OBJECT-IDENTITY STATUS current DESCRIPTION "E120 120Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing." ::= { es2SwitchFabricModule 3 } -- -- Adapter class - system controller I/O Adapter -- es2SrpIoa OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for the system controller I/O adapter for a second generation E-series system." ::= { juniES2EntPhysicalType 7 } e320SrpIoa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 SRP IOA. This card provides clocking functions as well as management and alarm interfaces." ::= { es2SrpIoa 1 } -- -- Module class - forwarding -- es2ForwardingModule OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series forwarding module." ::= { juniES2EntPhysicalType 8 } es2Lm4 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 4Gb (series 1) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic." ::= { es2ForwardingModule 1 } es2Lm10Uplink OBJECT-IDENTITY STATUS current DESCRIPTION "E320 10Gb (series 2) uplink line module. This Line Module is primarily focused on uplink IOAs and is responsible for processing data traffic." ::= { es2ForwardingModule 2 } es2Lm10 OBJECT-IDENTITY STATUS current DESCRIPTION "E320 10Gb (series 3) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic." ::= { es2ForwardingModule 3 } es2Lm10s OBJECT-IDENTITY STATUS current DESCRIPTION "E320 10Gb (series 4) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic." ::= { es2ForwardingModule 4 } -- -- Adapter class - forwarding I/O adapter -- es2ForwardingIoa OBJECT-IDENTITY STATUS current DESCRIPTION "The vendor type ID for a second generation E-series I/O adapter for a forwarding module." ::= { juniES2EntPhysicalType 9 } es2Ge4S1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 GE-4 IOA. This is a series 1, half-height, single wide IOA with 4 physical interfaces that require pluggable GE interfaces. This IOA uses the full capacity of a Series 1 line module." ::= { es2ForwardingIoa 1 } es2Oc48Stm16PosS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 OC48/STM16 POS IOA. This is a series 1, half-height, single wide IOA with 1 physical interface that requires a pluggable OC48/STM16 interface." ::= { es2ForwardingIoa 2 } es2ServiceS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 service IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces." ::= { es2ForwardingIoa 3 } es2Oc3Stm1x8AtmS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 OC3/STM1-8 ATM IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable OC3/STM1 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA)." ::= { es2ForwardingIoa 4 } es2RedundancyS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 redundancy IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces." ::= { es2ForwardingIoa 5 } es2Oc12Stm4x2PosS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 OC12/STM4-2 POS IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA)." ::= { es2ForwardingIoa 6 } es2Oc12Stm4x2AtmS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 OC12/STM4-2 ATM IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA)." ::= { es2ForwardingIoa 7 } es2dash10GeS1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 10GE IOA. This is a series 1, full-height, single wide IOA that supports 2 physical interface that requires a pluggable 10GE interface." ::= { es2ForwardingIoa 8 } es2Ge8S1Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 GE-8 IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 8 active or 4 active + 4 standby interfaces." ::= { es2ForwardingIoa 9 } es2dash10GePrS2Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 10GE IOA with port redundancy (PR). This is a series 2, full-height, single wide IOA that supports 2 physical interfaces (1 active + 1 standby) that require pluggable 10GE transceivers." ::= { es2ForwardingIoa 10 } es2Ge20S2Ioa OBJECT-IDENTITY STATUS current DESCRIPTION "E320 GE-20 IOA. This is a series 2, full-height, single wide IOA that supports 20 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 20 active or 10 active + 10 standby interfaces." ::= { es2ForwardingIoa 11 } END