LIEBERT-GP-NOTIFICATIONS-MIB DEFINITIONS ::= BEGIN IMPORTS sysUpTime FROM RFC1213-MIB MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI lgpNotifications, liebertNotificationsModuleReg FROM LIEBERT-GP-REGISTRATION-MIB lgpConditionId, lgpConditionDescr, lgpConditionTime, lgpConditionTableRef, lgpConditionTableRowRef FROM LIEBERT-GP-CONDITIONS-MIB ; -- ============================================================================= -- Module Identification and Registration -- ============================================================================= liebertGlobalProductsNotificationsModule MODULE-IDENTITY LAST-UPDATED "200807020000Z" ORGANIZATION "Liebert Corporation" CONTACT-INFO "Contact: Technical Support Postal: Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus OH, 43229 US Tel: +1 (800) 222-5877 E-mail: liebert.monitoring@vertivco.com Web: www.vertivco.com Author: Craig S. Ward" DESCRIPTION "The MIB module used to register Liebert SNMP OIDs. Copyright 2000-2008 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification." REVISION "200807020000Z" DESCRIPTION " o Added Notifications for PDU devices (power on/off). o Added lgpEventParameters branch for defining notification payload that specifically identifies objects that are contained in tables. o Added new varbind to the lgpEventConditionEntryAdded and lgpEventConditionEntryRemoved notifications. o Fixed minor SMIv2 warnings and issues " REVISION "200805150000Z" DESCRIPTION " o Added Notifications for PDU devices (power on/off). o Added lgpEventParameters branch for defining notification payload that specifically identifies objects that are contained in tables. o Added new varbind to the lgpEventConditionEntryAdded and lgpEventConditionEntryRemoved notifications. o Fixed minor SMIv2 warnings and issues " REVISION "200801100000Z" DESCRIPTION "Modified contact email address and deprecated both: o lgpEventAgentFirmwareUpdateSuccessful o lgpEventAgentFirmwareCorrupt which were moved to the LIEBERT-GP-AGENT-MIB document." REVISION "200608150000Z" DESCRIPTION "Added events for firmware update successful and for firmware corrupt." REVISION "200602220000Z" DESCRIPTION "Added support for Liebert DS Unit." ::= { liebertNotificationsModuleReg 1 } -- ============================================================================= -- lgpNotifications - Liebert Notifications Registrations -- ============================================================================= lgpEventNotifications OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications for Liebert Global Products." ::= { lgpNotifications 0 } lgpEventParameters OBJECT-IDENTITY STATUS current DESCRIPTION "This sub tree describes various parameters/data that are carried in the payload of some notifications." ::= { lgpNotifications 10 } lgpEventParmTableRef OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "This object will be included as a varbind in some lgpEventNotifications. It is a reference to a table object in the MIB. The value of this object will be the OID of a table that the object that the notification applies to is defined. The notification containing this object will also contain a varbind 'lgpEventParmTableRowRef' that will specify which instance (row) in the table the object is defined in. Example: NOTIFICATION: lgpEventConditionEntryAdded varbind: lgpConditionId 6 varbind: lgpConditionDescr lgpConditionRcpBranchBreakerOpen varbind: lgpConditionTime 393884848 varbind: lgpEventParmTableRef lgpPduRbTable varbind: lgpEventParmTableRowRef lgpPduRbEntryId.1.4 In the above example the breaker opened for a Receptacle branch. The specific receptacle branch is specified by the additional varbind (lgpEventParmTableRowRef). In this case the notification is for the 4th receptacle branch on the 1st PDU in the PDU cluster. " ::= { lgpEventParameters 5 } lgpEventParmTableRowRef OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "This is a reference to the intersection of a row and column (cell) in the table specified by the companion varbind (lgpEventParmTableRef) in this notification. The row in the table where this cell exists represents the object that this notification applies to. Example: NOTIFICATION: lgpEventRcpPowerStateChangeOff varbind: sysUpTime 393885975 varbind: lgpEventParmTableRef lgpPduRcpTable varbind: lgpEventParmTableRowRef lgpPduRcpEntryId.2.4.5 In the above example the power state changed for a Receptacle. The table containing the definition of the receptacle (lgpPduRcpTable) is given by the varbind (lgpEventParmTableRef) The specific receptacle is specified by the varbind (lgpEventParmTableRowRef). In this case the notification is for the 5th receptacle on the 4th receptacle branch on the 2nd PDU in the PDU cluster. If one wanted to retrieve the user assigned label for this receptacle the OID would be: lgpPduRcpEntryUsrLabel.2.4.5 " ::= { lgpEventParameters 6 } lgpEventConditionEntryAdded NOTIFICATION-TYPE OBJECTS { lgpConditionId, lgpConditionDescr, lgpConditionTime, lgpConditionTableRef, lgpConditionTableRowRef } STATUS current DESCRIPTION "This notification is sent each time a condition is inserted into the conditions table." ::= { lgpEventNotifications 1 } lgpEventConditionEntryRemoved NOTIFICATION-TYPE OBJECTS { lgpConditionId, lgpConditionDescr, lgpConditionTime, lgpConditionTableRef, lgpConditionTableRowRef } STATUS current DESCRIPTION "This notification is sent each time a condition is removed from the conditions table." ::= { lgpEventNotifications 2 } lgpEventLowBatteryWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The battery's remaining charge is less than or equal to the agent's configured low threshold 'lgpPwrConfigLowBatteryWarningTime'." ::= { lgpEventNotifications 3 } lgpEventLoadTransferedToBypass NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has transferred the load to the bypass source." ::= { lgpEventNotifications 4 } lgpEventInternalFault NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported an internal fault." ::= { lgpEventNotifications 5 } lgpEventBatteryTestFailed NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported a battery self-test failure." ::= { lgpEventNotifications 6 } lgpEventOutputOverload NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported an output overload condition." ::= { lgpEventNotifications 7 } lgpEventEstablishedPowerRedundancy NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has transitioned to the user defined redundant state." ::= { lgpEventNotifications 8 } lgpEventLostPowerRedundancy NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device as transitioned to a non-redundant power state as defined by the user configured threshold." ::= { lgpEventNotifications 9 } lgpEventPowerModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device power module failure." ::= { lgpEventNotifications 10 } lgpEventBatteryModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device battery module failure." ::= { lgpEventNotifications 11 } lgpEventControlModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device control module failure." ::= { lgpEventNotifications 12 } lgpEventPowerModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device power module warning." ::= { lgpEventNotifications 13 } lgpEventBatteryModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device battery module warning." ::= { lgpEventNotifications 14 } lgpEventControlModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device control module warning." ::= { lgpEventNotifications 15 } lgpEventAgentFirmwareUpdateSuccessful NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS deprecated DESCRIPTION "The firmware update to the agent card has completed successfully. This element has been relocated to lgpAgentFirmwareUpdateSuccessful in the LIEBERT-GP-AGENT-MIB document." ::= { lgpEventNotifications 16 } lgpEventAgentFirmwareCorrupt NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS deprecated DESCRIPTION "The firmware update to the agent card has failed and the firmware is now corrupt. This element has been relocated to lgpAgentFirmwareCorrupt in the LIEBERT-GP-AGENT-MIB document." ::= { lgpEventNotifications 17 } lgpEventConfigModified NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "Configuration for the referenced PDU has been modified." ::= { lgpEventNotifications 18 } lgpEventModuleAdded NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "A hot-swappable module has been added to the object specified by the lgpEventParmTableRef and lgpEventParmTableRowRef." ::= { lgpEventNotifications 19 } lgpEventModuleRemoved NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "A hot-swappable module has been removed from the object specified by the lgpEventParmTableRef and lgpEventParmTableRowRef." ::= { lgpEventNotifications 20 } lgpEventRcpPowerStateChangeOn NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "Receptacle's power state has been changed from OFF to ON." ::= { lgpEventNotifications 21 } lgpEventRcpPowerStateChangeOff NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "Receptacle's power state has been changed from ON to OFF." ::= { lgpEventNotifications 22 } lgpEventRcpLoadAdded NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "The receptacle's load started drawing power. This notification is asserted when the receptacle power is ON and the associated load was previously not drawing power but is now drawing power. This event is not asserted as a result of turning the receptacle power ON." ::= { lgpEventNotifications 23 } lgpEventRcpLoadRemoved NOTIFICATION-TYPE OBJECTS { sysUpTime, lgpEventParmTableRef, lgpEventParmTableRowRef } STATUS current DESCRIPTION "The receptacle's load stopped drawing power. This notification is asserted when the receptacle power is ON and the associated load was previously drawing power but is now no longer drawing power. This event is not asserted as a result of turning the receptacle power OFF." ::= { lgpEventNotifications 24 } END