LINKSYS-Physicaldescription-MIB DEFINITIONS ::= BEGIN -- Version: 7.46 -- Date: 15-Jan-2007 -- -- 30-Jan-2004 Add rlPhdUnitGenParamTable -- 30-Jan-2004 Add rlPhdUnitEnvParamTable -- 24-Feb-2004 Add rlPhdStackOrderTopUnit -- 24-Feb-2004 Add rlPhdStackOrderBottomUnit -- 24-Feb-2004 Add rlPhdStackOrderPermutation -- 21-Apr-2005 Add rlPhdPortsTable switch description between: -- rlPhdPortsModuleNumber && rlPhdPortsStackUnit due to EWS need -- 27-Apr-2005 Add rlStackLinkChange trap. -- 16-May-2005 Add rlPhdNumberOfPoeUnits -- 02-Jun-2005 Add field to rlPhDUnitEnvParamTable: rlPhdUnitEnvParamUpTime -- 25-Jul-2005 Add rlPhdPhyLedTimeout and rlPhdPhyLedStackUnit -- 03-Aug-2005 Remove boundary for unit number field, checked by box -- this is done coz different products use different stack size -- 05-Sep-2005 Add rlCascadeTable -- 31-Oct-2005 Add rlCascadeAfterResetTable -- 14-Nov-2005 Change rlPhdUnitGenParamSerialNum to read-write -- 16-May-2006 Add field rlCascadeUnitId to rlCascadeEntry -- 14-Jan-2007 rlPhdModuleType was moved to a separated text file -- 15-Jan-2007 Devided file appolo.txt to a few files -- Renamed file appolo.txt to ralan-mib.mib -- 23-Jul-2012 IdanS: Add rlPhdUnitGenParamRegistrationDone and rlPhdUnitGenParamRegistrationSuppressed to RlPhdUnitGenParamEntry -- 09-Oct-2012 yahal: Add rlPhdUnitEnvParamMonitorAutoRecoveryEnable & rlPhdUnitEnvParamMonitorTemperatureStatus & rlPhdUnitEnvParamMonitorTemperatureStatus IMPORTS OBJECT-TYPE, MODULE-IDENTITY, TimeTicks, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC JackType FROM MAU-MIB rnd, rndNotifications FROM LINKSYS-MIB RlEnvMonState FROM LINKSYS-HWENVIROMENT EntitySensorStatus, EntitySensorValue FROM ENTITY-SENSOR-MIB InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB rndErrorDesc, rndErrorSeverity FROM LINKSYS-DEVICEPARAMS-MIB; rlPhysicalDescription MODULE-IDENTITY LAST-UPDATED "200602120000Z" ORGANIZATION "Linksys LLC." CONTACT-INFO "www.linksys.com/business/support" DESCRIPTION "The private MIB module definition for physical device configuration." REVISION "200602120000Z" DESCRIPTION "Removed TRAP-TYPE from IMPORTS." REVISION "200310180000Z" DESCRIPTION "Initial version of this MIB." ::= { rnd 53 } rlPhdMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "MIB's version, the current version is 3. 1: original version 2: a. new tables rlPhdModuleHotSwapTable rlPhdStackOrderTable b. new scalars rlPhdStackReorder rlPhdNumberOfUnits rlPhdMaxNumberOfUnits 3: a. new field rlPhdModuleRole of rlPhdModuleTable b. new scalars rlPhdForceMasterUnit 4: a. new fields rlPhdModuleConnect1 and rlPhdModuleConnect2 of rlPhdModuleTable. 5: a. Prefix rlPhD were replaced by prefix rlPhd b. fields rlPhdModuleConnect1 and rlPhdModuleConnect2 are moved from rlPhdModuleTable to rlPhdStackTable. c. new fiels rlPhdStackSofrwareVer, rlPhdStackProductID and rlPhdStackMacAddr of rlPhdStackTable. d. new scalars rlPhdStackReloadUnit e. new scalars rlPhdStackOrderTopUnit rlPhdStackOrderBottomUnit rlPhdStackOrderPermutation" ::= { rlPhysicalDescription 1 } rlPhdModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each module (board) there is an entry describing it in this module" ::= { rlPhysicalDescription 2 } rlPhdModuleEntry OBJECT-TYPE SYNTAX RlPhdModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a module (board)" INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex} ::= { rlPhdModuleTable 1 } RlPhdModuleEntry ::= SEQUENCE { rlPhdModuleStackUnit INTEGER, rlPhdModuleIndex INTEGER, rlPhdModuleType INTEGER, rlPhdModuleStartingPort INTEGER, rlPhdModuleNumberOfPorts INTEGER, rlPhdModuleRow INTEGER, rlPhdModuleColumn INTEGER, rlPhdModuleRole INTEGER } rlPhdModuleStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the stack unit" ::= { rlPhdModuleEntry 1 } rlPhdModuleIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the module in its stack unit" ::= { rlPhdModuleEntry 2 } rlPhdModuleType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index for each module type" ::= { rlPhdModuleEntry 3 } rlPhdModuleStartingPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The minimal number of the port residing on this module." ::= { rlPhdModuleEntry 4 } rlPhdModuleNumberOfPorts OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ports residing on this module." ::= { rlPhdModuleEntry 5} rlPhdModuleRow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "On which row (the uppermost being numbered 1 and the highest row number asigned to the lowest row) this module resides within the chassis of its stack unit." ::= { rlPhdModuleEntry 6 } rlPhdModuleColumn OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "On which column (the leftmost being numbered 1 and the highest column number asigned to the rightmost column) this module resides within the chassis of its stack unit." ::= { rlPhdModuleEntry 7 } rlPhdModuleRole OBJECT-TYPE SYNTAX INTEGER { standalone(1), master(2), backup(3), slave(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The module role in the stack." DEFVAL { standalone } ::= { rlPhdModuleEntry 8 } rlPhdPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lists the physical or physical-related attributes of ports" ::= { rlPhysicalDescription 3 } rlPhdPortsEntry OBJECT-TYPE SYNTAX RlPhdPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each port, a entry describing attributes which are either physical or are derived from the features of the device hardware" INDEX { rlPhdPortsIfIndex } ::= { rlPhdPortsTable 1 } RlPhdPortsEntry ::= SEQUENCE { rlPhdPortsIfIndex INTEGER, rlPhdPortsIfIndexName DisplayString(SIZE(1..20)), rlPhdPortsMediaType INTEGER, rlPhdPortsStackUnit INTEGER, rlPhdPortsModuleNumber INTEGER, rlPhdPortsRow INTEGER, rlPhdPortsColumn INTEGER, rlPhdConnectorType JackType, rlPhdPortHaul INTEGER } rlPhdPortsIfIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The L2 interface number associated with this port." ::= { rlPhdPortsEntry 1 } rlPhdPortsIfIndexName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The L2 interface number associated with this port, in string format based on the overall hardware architecture of the device (i.e., for monolithic devices just numbers, devices composed of modules (boards, cards) or stackable devices composed of monolithic units in form - , stackable devices in which each unit is composed of modules - - " ::= { rlPhdPortsEntry 2 } rlPhdPortsMediaType OBJECT-TYPE SYNTAX INTEGER {copper(1), optic-fiber(2), combo(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "The media type of this port." ::= { rlPhdPortsEntry 3 } rlPhdPortsStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the slot to which this port belongs." ::= { rlPhdPortsEntry 4 } rlPhdPortsModuleNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the stack unit to which this port resides in." ::= { rlPhdPortsEntry 5 } rlPhdPortsRow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "On which row (the uppermost being numbered 1 and the highest row number asigned to the lowest row) this port resides within its module." ::= { rlPhdPortsEntry 6 } rlPhdPortsColumn OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "On which column (the leftmost being numbered 1 and the highest column number asigned to the rightmost column) this this port resides within its module." ::= { rlPhdPortsEntry 7 } rlPhdConnectorType OBJECT-TYPE SYNTAX JackType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of connector." ::= { rlPhdPortsEntry 8 } rlPhdPortHaul OBJECT-TYPE SYNTAX INTEGER { not-relevant(1), short(2), long(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Distance supported by this port." ::= { rlPhdPortsEntry 9 } rlPhdStackTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdStackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each stack unit there is an entry describing it in this table" ::= { rlPhysicalDescription 4 } rlPhdStackEntry OBJECT-TYPE SYNTAX RlPhdStackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a stack unit" INDEX { rlPhdStackUnit } ::= { rlPhdStackTable 1 } RlPhdStackEntry ::= SEQUENCE { rlPhdStackUnit INTEGER, rlPhdStackType INTEGER, rlPhdStackConnect1 INTEGER, rlPhdStackConnect2 INTEGER, rlPhdStackSofrwareVer DisplayString, rlPhdStackProductID DisplayString, rlPhdStackMacAddr PhysAddress } rlPhdStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The stack unit described by this entry." ::= { rlPhdStackEntry 1 } rlPhdStackType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the stack unit described by this entry: 1 - box 3202 2 - box LG 3 - bcm 4 - prestera" ::= { rlPhdStackEntry 2 } rlPhdStackConnect1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The unit number connected to the Hyper GLink left side connection - 0 means not connected; other integer indicates the unit number." DEFVAL { 0 } ::= { rlPhdStackEntry 3 } rlPhdStackConnect2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The unit number connected to the Hyper GLink right side connection - 0 means not connected; other integer indicates the unit number." DEFVAL { 0 } ::= { rlPhdStackEntry 4 } rlPhdStackSofrwareVer OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Software version of the unit." ::= { rlPhdStackEntry 5 } rlPhdStackProductID OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Product ID of the unit." ::= { rlPhdStackEntry 6 } rlPhdStackMacAddr OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The physical (MAC) address of the unit." ::= { rlPhdStackEntry 7 } rlPhdModuleHotSwapTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdModuleHotSwapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each module (board) there is an entry describing its Hot Swap status" ::= { rlPhysicalDescription 5 } rlPhdModuleHotSwapEntry OBJECT-TYPE SYNTAX RlPhdModuleHotSwapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a module (board) Hot Swap status" INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex} ::= { rlPhdModuleHotSwapTable 1 } RlPhdModuleHotSwapEntry ::= SEQUENCE { rlPhdModuleHotSwapAdminStatus INTEGER, rlPhdModuleHotSwapOperStatus INTEGER } rlPhdModuleHotSwapAdminStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the module. The off(1) state indicates that the module is not used and its rlPhdModuleHotSwapOperStatus is always off(2). The on{1) state indicates that the module may be used and its rlPhdModuleHotSwapOperStatus will be on(1) if it presents and off(2) if it does not present." DEFVAL { on } ::= { rlPhdModuleHotSwapEntry 1 } rlPhdModuleHotSwapOperStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current Hot Swap state of the module. If rlPhdModuleHotSwapAdminStatus is down(2) then rlPhdModuleHotSwapOperStatus should be down(2). If rlPhdModuleHotSwapAdminStatus is changed to up(1) then rlPhdModuleHotSwapOperStatus should change to up(1) if the module presents; it should remain in the down(2) state if and only if the module does not present." ::= { rlPhdModuleHotSwapEntry 2 } rlPhdStackOrderTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdStackOrderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to configure the order of the stack units as displayed on his GUI. The order of the entries in this table corresponds to the last configured order. If the stack units order was never configured, the order will be the same as in the rlPhdStackTable." ::= { rlPhysicalDescription 6 } rlPhdStackOrderEntry OBJECT-TYPE SYNTAX RlPhdStackOrderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a stack unit in the position desired by the user" INDEX { rlPhdStackOrderCurrentUnitPosition } ::= { rlPhdStackOrderTable 1 } RlPhdStackOrderEntry ::= SEQUENCE { rlPhdStackOrderCurrentUnitPosition INTEGER, rlPhdStackOrderDesiredUnitPosition INTEGER, rlPhdStackOrderUnitIndex INTEGER, rlPhdStackOrderUnitType INTEGER } rlPhdStackOrderCurrentUnitPosition OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "The current stack unit position." ::= { rlPhdStackOrderEntry 1 } rlPhdStackOrderDesiredUnitPosition OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The desired stack unit position. Note that setting this MIB object will take effect only after setting the rlPhdStackReorder MIB object below. After setting this MIB object and until a further change of at least one instance of the rlPhdStackOrderDesiredUnitPosition object, the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and the corresponding rlPhdStackOrderDesiredUnitPosition object instance will be the same." ::= { rlPhdStackOrderEntry 2 } rlPhdStackOrderUnitIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the original unit index, i.e. has the same value as rlPhdStackUnit above." ::= { rlPhdStackOrderEntry 3 } rlPhdStackOrderUnitType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the stack unit described by this entry. It has the same value as rlPhdStackType above. This information is duplicated here only for easier retrieval by the device manager." ::= { rlPhdStackOrderEntry 4 } rlPhdStackReorder OBJECT-TYPE SYNTAX INTEGER {reorder(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this MIB object will cause the settings of the rlPhdStackOrderDesiredUnitPosition MIB object instances to take effect. After setting this MIB object and until a further change of at least one instance of the rlPhdStackOrderDesiredUnitPosition object, the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and the corresponding rlPhdStackOrderDesiredUnitPosition object instance will be the same." ::= { rlPhysicalDescription 7 } rlPhdNumberOfUnits OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the current number of units in the stack." ::= { rlPhysicalDescription 8 } rlPhdMaxNumberOfUnits OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the maximum number of units in the stack." ::= { rlPhysicalDescription 9 } rlPhdForceMasterUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Force unit to be master." ::= { rlPhysicalDescription 10 } -- The following scalar isn't suported and will be removed rlPhdStackFixedUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Determine which unit will be on bottom/top of list on Show-List command(see ." ::= { rlPhysicalDescription 11 } -- The following scalar isn't suported and will be removed rlPhdStackFixedUnitLocation OBJECT-TYPE SYNTAX INTEGER{ bottom(1), top(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the bottom/top object in the stack table." ::= { rlPhysicalDescription 12 } rlPhdStackReloadUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Reset a specific unit." ::= { rlPhysicalDescription 13 } rlPhdUnitGenParamTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdUnitGenParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each module (board) there is an entry describing it in this module" ::= { rlPhysicalDescription 14 } rlPhdUnitGenParamEntry OBJECT-TYPE SYNTAX RlPhdUnitGenParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a module (board)" INDEX { rlPhdUnitGenParamStackUnit} ::= { rlPhdUnitGenParamTable 1 } RlPhdUnitGenParamEntry ::= SEQUENCE { rlPhdUnitGenParamStackUnit INTEGER, rlPhdUnitGenParamSoftwareVersion DisplayString, rlPhdUnitGenParamFirmwareVersion DisplayString, rlPhdUnitGenParamHardwareVersion DisplayString, rlPhdUnitGenParamSerialNum DisplayString, rlPhdUnitGenParamAssetTag DisplayString, rlPhdUnitGenParamServiceTag DisplayString, rlPhdUnitGenParamSoftwareDate DisplayString, rlPhdUnitGenParamFirmwareDate DisplayString, rlPhdUnitGenParamManufacturer DisplayString, rlPhdUnitGenParamModelName DisplayString, rlPhdUnitGenParamMd5ChksumBoot DisplayString, rlPhdUnitGenParamMd5ChksumImage1 DisplayString, rlPhdUnitGenParamMd5ChksumImage2 DisplayString, rlPhdUnitGenParamRegistrationDone TruthValue, rlPhdUnitGenParamRegistrationSuppressed TruthValue } rlPhdUnitGenParamStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the stack unit to which this conceptual row corresponds." ::= { rlPhdUnitGenParamEntry 1 } rlPhdUnitGenParamSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the product." ::= { rlPhdUnitGenParamEntry 2 } rlPhdUnitGenParamFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the product." ::= { rlPhdUnitGenParamEntry 3 } rlPhdUnitGenParamHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the product." ::= { rlPhdUnitGenParamEntry 4 } rlPhdUnitGenParamSerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Serial number of the product." ::= { rlPhdUnitGenParamEntry 5 } rlPhdUnitGenParamAssetTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Serial number of the product." ::= { rlPhdUnitGenParamEntry 6 } rlPhdUnitGenParamServiceTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Asset tag of the product." ::= { rlPhdUnitGenParamEntry 7 } rlPhdUnitGenParamSoftwareDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date of product's software." ::= { rlPhdUnitGenParamEntry 8 } rlPhdUnitGenParamFirmwareDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date of product's firmware." ::= { rlPhdUnitGenParamEntry 9 } rlPhdUnitGenParamManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Product's Manufacturer." ::= { rlPhdUnitGenParamEntry 10 } rlPhdUnitGenParamModelName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Model Name." ::= { rlPhdUnitGenParamEntry 11 } rlPhdUnitGenParamMd5ChksumBoot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MD5 Checksum for Boot" ::= { rlPhdUnitGenParamEntry 12 } rlPhdUnitGenParamMd5ChksumImage1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MD5 Checksum for Image 1" ::= { rlPhdUnitGenParamEntry 13 } rlPhdUnitGenParamMd5ChksumImage2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MD5 Checksum for Image 2" ::= { rlPhdUnitGenParamEntry 14 } rlPhdUnitGenParamRegistrationDone OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Registration Done." ::= { rlPhdUnitGenParamEntry 15 } rlPhdUnitGenParamRegistrationSuppressed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Registration Suppressed." ::= { rlPhdUnitGenParamEntry 16 } rlPhdUnitEnvParamTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdUnitEnvParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each module (board) there is an entry describing it in this module" ::= { rlPhysicalDescription 15 } rlPhdUnitEnvParamEntry OBJECT-TYPE SYNTAX RlPhdUnitEnvParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a module (board)" INDEX { rlPhdUnitEnvParamStackUnit} ::= { rlPhdUnitEnvParamTable 1 } RlPhdUnitEnvParamEntry ::= SEQUENCE { rlPhdUnitEnvParamStackUnit INTEGER, rlPhdUnitEnvParamMainPSStatus RlEnvMonState, rlPhdUnitEnvParamRedundantPSStatus RlEnvMonState, rlPhdUnitEnvParamFan1Status RlEnvMonState, rlPhdUnitEnvParamFan2Status RlEnvMonState, rlPhdUnitEnvParamFan3Status RlEnvMonState, rlPhdUnitEnvParamFan4Status RlEnvMonState, rlPhdUnitEnvParamFan5Status RlEnvMonState, rlPhdUnitEnvParamTempSensorValue EntitySensorValue, rlPhdUnitEnvParamTempSensorStatus EntitySensorStatus, rlPhdUnitEnvParamUpTime TimeTicks, rlPhdUnitEnvParamMonitorAutoRecoveryEnable TruthValue, rlPhdUnitEnvParamMonitorTemperatureStatus INTEGER, rlPhdUnitEnvParamMonitorOperStatus TruthValue } rlPhdUnitEnvParamStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the stack unit to which this conceptual row corresponds. Note that the index will be the same index as the index of a 'chassis' physical entity in the entity MIB of the product." ::= { rlPhdUnitEnvParamEntry 1 } rlPhdUnitEnvParamMainPSStatus OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the main PS being instrumented." ::= { rlPhdUnitEnvParamEntry 2 } rlPhdUnitEnvParamRedundantPSStatus OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the redundant PS being instrumented." ::= { rlPhdUnitEnvParamEntry 3 } rlPhdUnitEnvParamFan1Status OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the FAN 1 being instrumented." ::= { rlPhdUnitEnvParamEntry 4 } rlPhdUnitEnvParamFan2Status OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the FAN 2 being instrumented." ::= { rlPhdUnitEnvParamEntry 5 } rlPhdUnitEnvParamFan3Status OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the FAN 3 being instrumented." ::= { rlPhdUnitEnvParamEntry 6 } rlPhdUnitEnvParamFan4Status OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the FAN 4 being instrumented." ::= { rlPhdUnitEnvParamEntry 7 } rlPhdUnitEnvParamFan5Status OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the FAN 5 being instrumented." ::= { rlPhdUnitEnvParamEntry 8 } rlPhdUnitEnvParamTempSensorValue OBJECT-TYPE SYNTAX EntitySensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "Current value for the Sensor being instrumented." ::= { rlPhdUnitEnvParamEntry 9 } rlPhdUnitEnvParamTempSensorStatus OBJECT-TYPE SYNTAX EntitySensorStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status value for the Sensor being instrumented." ::= { rlPhdUnitEnvParamEntry 10 } rlPhdUnitEnvParamUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Up time of the unit in 100th of second (sec/100)." ::= { rlPhdUnitEnvParamEntry 11 } rlPhdUnitEnvParamMonitorAutoRecoveryEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Disable environment automatic recovery option" ::= { rlPhdUnitEnvParamEntry 12 } rlPhdUnitEnvParamMonitorTemperatureStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), overTemperatureThreshold(2), overCriticalTemperatureThreshold(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Display environment monitoring chassis temperature status" ::= { rlPhdUnitEnvParamEntry 13 } rlPhdUnitEnvParamMonitorOperStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Display environment automatic recovery current status (active/not active)" ::= { rlPhdUnitEnvParamEntry 14 } rlPhdStackOrderTopUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This scalar mib holds the Top unit for the stack order command" ::= { rlPhysicalDescription 16 } rlPhdStackOrderBottomUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This scalar mib holds the Bottom unit for the stack order command" ::= { rlPhysicalDescription 17 } rlPhdStackOrderPermutation OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This scalar mib holds stack permutation" ::= { rlPhysicalDescription 18 } rlPhdNumberOfPoeUnits OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the current number of poe units in the stack." ::= { rlPhysicalDescription 19 } rlPhdPoeTable OBJECT-TYPE SYNTAX SEQUENCE OF RlPhdPoeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each module (board) there is an entry describing it in this module" ::= { rlPhysicalDescription 20 } rlPhdPoeEntry OBJECT-TYPE SYNTAX RlPhdPoeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a module (board)" INDEX { rlPhdPoeStackUnit } ::= { rlPhdPoeTable 1 } RlPhdPoeEntry ::= SEQUENCE { rlPhdPoeStackUnit INTEGER, rlPhdPoePresent INTEGER } rlPhdPoeStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The stack unit to which this module belongs." ::= { rlPhdPoeEntry 1 } rlPhdPoePresent OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present state of the PoE module. The no(1) state indicates that the PoE module is not present. The yes{2) state indicates that the PoE module is present." ::= { rlPhdPoeEntry 2 } -- The light unit scalars rlPhdPhyLedStackUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This scalar mib holds the unit number for the stack light command" ::= { rlPhysicalDescription 21 } rlPhdPhyLedTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This scalar mib holds the timeout for the stack light command. May be in the range 2..60 sec. (default - 5 sec.), if the timeout = 0 - all units return to normal state." ::= { rlPhysicalDescription 22 } rlCascadeTable OBJECT-TYPE SYNTAX SEQUENCE OF RlCascadeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each cascaded port for stacking unit there is an entry describing it in this table" ::= { rlPhysicalDescription 23 } rlCascadeEntry OBJECT-TYPE SYNTAX RlCascadeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of this table specifies a cascaded link information in a unit" INDEX { ifIndex } ::= { rlCascadeTable 1 } RlCascadeEntry ::= SEQUENCE { rlCascadeNeighborIfIndex InterfaceIndexOrZero, rlCascadeNeighborUnit INTEGER, rlCascadeTrunkId INTEGER, rlCascadeUnitId INTEGER } rlCascadeNeighborIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex of a stacking port in the neighbor unit - 0 means not connected; other integer indicates the IfIndex." ::= { rlCascadeEntry 1 } rlCascadeNeighborUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The unit number of the neighbor unit - 0 means not connected; other integer indicates the unit number." ::= { rlCascadeEntry 2 } rlCascadeTrunkId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The id of the trunk, the stacking port is member, zero if the port is not member of trunk." ::= { rlCascadeEntry 3 } rlCascadeUnitId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The unit number matching the current ifIndex" ::= { rlCascadeEntry 4 } rlCascadeAfterResetTable OBJECT-TYPE SYNTAX SEQUENCE OF RlCascadeAfterResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For each cascaded port for stacking unit there is an entry describing it in this table after reset" ::= { rlPhysicalDescription 24 } rlCascadeAfterResetEntry OBJECT-TYPE SYNTAX RlCascadeAfterResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A entry of this table specifies a cascaded port information in a unit after reset" INDEX { rlCascadeIfIndexAfterReset } ::= { rlCascadeAfterResetTable 1 } RlCascadeAfterResetEntry ::= SEQUENCE { rlCascadeIfIndexAfterReset InterfaceIndex, rlCascadeTrunkIdAfterReset INTEGER, rlCascadeRowStatus RowStatus } rlCascadeIfIndexAfterReset OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex of a stacking port after reset." ::= { rlCascadeAfterResetEntry 1 } rlCascadeTrunkIdAfterReset OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The Id of the trunk, the stacking port will be member after reset, zero if the port is not member of trunk." ::= { rlCascadeAfterResetEntry 2 } rlCascadeRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry." ::= { rlCascadeAfterResetEntry 3 } -- Stack MIB Trap Definitions rlStackUnitRemoved NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that a unit was removed from the stack." ::= { rndNotifications 186 } rlStackConfigChangedRingChain NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that the configuration of the stack has changed. - from ring to chain - from chain to ring." ::= { rndNotifications 187 } rlStackBackupUnitRemoved NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that the backup unit was removed from the stack." ::= { rndNotifications 188 } rlStackMasterSwitchover NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that a new master was elected. The old maste is the backup now. " ::= { rndNotifications 189 } rlStackUnitDifferentSwVersion NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that the new unit added to the stack has different software version than the master." ::= { rndNotifications 190 } rlStackDuplicateUnitNotJoin NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that a new unit with duplicated unit id was added to the stack - but it will not join the stack." ::= { rndNotifications 191 } rlStackLinkChange NOTIFICATION-TYPE OBJECTS { rndErrorDesc, rndErrorSeverity } STATUS current DESCRIPTION "Trap indicating that Link has change in one of the Stacking Ports." ::= { rndNotifications 195 } END