NBS-SIGCOND-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Unsigned32, OBJECT-TYPE, NOTIFICATION-TYPE,
    MODULE-IDENTITY, OBJECT-IDENTITY
        FROM SNMPv2-SMI

    InterfaceIndex, ifAlias
        FROM IF-MIB

    nbs, NbsTcMilliDb, NbsTcMHz
        FROM NBS-MIB;


nbsSigCondMib  MODULE-IDENTITY
    LAST-UPDATED "201707270000Z"  -- July 27, 2017
    ORGANIZATION "NBS"
    CONTACT-INFO
      "For technical support, please contact your service channel"

    DESCRIPTION
      "Signal Conditioning mib"
    ::= { nbs 227 }

-- *******************************************************************
-- NBS-SIGCOND-MIB local defines
-- *******************************************************************

nbsSigCondVoaPortGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Variable Optical Attenuation at the port level."
    ::= { nbsSigCondMib 1 }

nbsSigCondVoaChannelGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Variable Optical Attenuation at the channel level."
    ::= { nbsSigCondMib 2}

nbsSigCondRamanGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Raman amplifier information for the port."
    ::= { nbsSigCondMib 3 }

nbsSigCondEqualizeGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Management info for equalizing power levels among channels
       within a WDM port"
    ::= { nbsSigCondMib 20 }

nbsSigCondRedundGrp   OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Management info for power level based redundancy"
    ::= { nbsSigCondMib 30 }

nbsSigCondPortGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Power readings from the port."
    ::= { nbsSigCondMib 40 }

nbsSigCondChannelGrp   OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Signal info for WDM channels within a WDM port"
    ::= { nbsSigCondMib 50 }

nbsSigCondVodPortGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
      "Dispersion compensation at the port level."
    ::= { nbsSigCondMib 60 }


nbsSigCondTraps  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION "SNMP Traps or Notifications"
    ::= { nbsSigCondMib 200 }

nbsSigCondEvent OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION "SNMP Traps or Notifications"
    ::= { nbsSigCondTraps 0 }


-- *******************************************************************
--
-- the nbsSigCondVoaPortTable
--
-- *******************************************************************

nbsSigCondVoaPortTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of ports supporting variable optical attenuation
           at the port level."
        ::= { nbsSigCondVoaPortGrp 1 }

nbsSigCondVoaPortTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF NbsSigCondVoaPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "List of ports supporting variable optical attenuation at the
           port level."
        ::= { nbsSigCondVoaPortGrp 2 }

NbsSigCondVoaPortEntry ::= SEQUENCE {
        nbsSigCondVoaPortIfIndex        InterfaceIndex,
        nbsSigCondVoaPortRxAttenuAdmin  INTEGER,
        nbsSigCondVoaPortRxAttenuOper   INTEGER,
        nbsSigCondVoaPortTxAttenuAdmin  INTEGER,
        nbsSigCondVoaPortTxAttenuOper   INTEGER
}

nbsSigCondVoaPortEntry      OBJECT-TYPE
        SYNTAX      NbsSigCondVoaPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          ""
        INDEX { nbsSigCondVoaPortIfIndex }
        ::= { nbsSigCondVoaPortTable 1 }

nbsSigCondVoaPortIfIndex   OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The Mib2 ifIndex of the attenuable port."
        ::= { nbsSigCondVoaPortEntry 1 }

nbsSigCondVoaPortRxAttenuAdmin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "Persistent and immediately updated.  User-requested
           attenuation to be applied to received signal, expressed in
           millidecibels (mdB).
           Not supported value: -200000"
        DEFVAL { 0 }
        ::= { nbsSigCondVoaPortEntry 2 }

nbsSigCondVoaPortRxAttenuOper OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Attenuation actually being applied to received signal, in
           millidecibels (mdB).
           Not supported value: -200000"
        DEFVAL { 0 }
        ::= { nbsSigCondVoaPortEntry 3 }

nbsSigCondVoaPortTxAttenuAdmin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "Persistent and immediately updated.  User-requested
           attenuation to be applied before transmitting signal,
           expressed in millidecibels (mdB).
           Not supported value: -200000"
        DEFVAL { 0 }
        ::= { nbsSigCondVoaPortEntry 4 }

nbsSigCondVoaPortTxAttenuOper OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Attenuation actually being applied before transmitting
           signal, in millidecibels (mdB).
           Not supported value: -200000"
        DEFVAL { 0 }
        ::= { nbsSigCondVoaPortEntry 5}



-- *******************************************************************
--
-- the nbsSigCondVoaChannelTbl
--
-- *******************************************************************

nbsSigCondVoaChannelRangeTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of mux ports supporting variable optical
           attenuation at the channel level."
        ::= { nbsSigCondVoaChannelGrp 1 }

nbsSigCondVoaChannelRangeTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF NbsSigCondVoaChannelRangeEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The channel attenuation values supported on this port."
        ::= { nbsSigCondVoaChannelGrp 2 }

NbsSigCondVoaChannelRangeEntry ::= SEQUENCE {
        nbsSigCondVoaChannelRangeIfIndex InterfaceIndex,
        nbsSigCondVoaChannelRangeMin     NbsTcMilliDb,
        nbsSigCondVoaChannelRangeMax     NbsTcMilliDb,
        nbsSigCondVoaChannelRangeIncr    NbsTcMilliDb
}

nbsSigCondVoaChannelRangeEntry      OBJECT-TYPE
        SYNTAX      NbsSigCondVoaChannelRangeEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          ""
        INDEX { nbsSigCondVoaChannelRangeIfIndex }
        ::= { nbsSigCondVoaChannelRangeTable 1 }

nbsSigCondVoaChannelRangeIfIndex   OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The Mib2 ifIndex of the mux port."
        ::= { nbsSigCondVoaChannelRangeEntry 1 }

nbsSigCondVoaChannelRangeMin     OBJECT-TYPE
        SYNTAX      NbsTcMilliDb
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The lowest channel attenuation value supported by this mux
           port, expressed in millidecibels (mdB).

           This is the smallest attenuation supported."
        DEFVAL { 0 }
        ::= { nbsSigCondVoaChannelRangeEntry 2 }

nbsSigCondVoaChannelRangeMax     OBJECT-TYPE
        SYNTAX      NbsTcMilliDb
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The greatest channel attenuation value supported by this mux
           port, expressed in millidecibels (mdB).

           This is the largest attenuation supported."
        DEFVAL { 0 }
        ::= { nbsSigCondVoaChannelRangeEntry 3 }


nbsSigCondVoaChannelRangeIncr     OBJECT-TYPE
        SYNTAX      NbsTcMilliDb
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The precision of the VOA, expressed in
           millidecibels (mdB).

           The minimum difference between attenuation values."
        DEFVAL { 0 }
        ::= { nbsSigCondVoaChannelRangeEntry 4 }

-- *******************************************************************
--
-- the nbsSigCondRamanTable
--
-- *******************************************************************

nbsSigCondRamanTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of raman ports in this system."
        ::= { nbsSigCondRamanGrp 1 }

nbsSigCondRamanTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF NbsSigCondRamanEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "Table of Raman readings."
        ::= { nbsSigCondRamanGrp 2 }

NbsSigCondRamanEntry ::= SEQUENCE {
        nbsSigCondRamanIfIndex      InterfaceIndex,
        nbsSigCondRamanPumpPwrAdmin INTEGER,
        nbsSigCondRamanPumpPwrOper  INTEGER
}

nbsSigCondRamanEntry      OBJECT-TYPE
        SYNTAX      NbsSigCondRamanEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "Raman readings on an individual port."
        INDEX { nbsSigCondRamanIfIndex }
        ::= { nbsSigCondRamanTable 1 }

nbsSigCondRamanIfIndex   OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The Mib2 ifIndex of the Raman port"
        ::= { nbsSigCondRamanEntry 1 }

nbsSigCondRamanPumpPwrAdmin OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "Persistent and immediately updated.  User-requested pump
           power,  in microwatts (uW).
           User interfaces should show this in millWatts (mW).
           Not supported value:  -1"
        ::= { nbsSigCondRamanEntry 2 }

nbsSigCondRamanPumpPwrOper OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Agent reported pump power, in microwatts (uW).
           User interfaces should show this in millWatts (mW).
           Not supported value:  -1"
        ::= { nbsSigCondRamanEntry 3 }


-- *******************************************************************
--
-- the nbsSigCondEqualizeTable
--
-- *******************************************************************

nbsSigCondEqualizeTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The number of entries in nbsSigCondEqualizeTable."
    ::= { nbsSigCondEqualizeGrp 1 }

nbsSigCondEqualizeTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSigCondEqualizeEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "List of WDM ports supporting power level equalization."
    ::= { nbsSigCondEqualizeGrp 2 }

NbsSigCondEqualizeEntry ::= SEQUENCE {
    nbsSigCondEqualizeIfIndex       InterfaceIndex,
    nbsSigCondEqualizeState         INTEGER,
    nbsSigCondEqualizeLimitMin      NbsTcMilliDb,
    nbsSigCondEqualizeLimitMax      NbsTcMilliDb,
    nbsSigCondEqualizeDesiredMin    NbsTcMilliDb,
    nbsSigCondEqualizeDesiredMax    NbsTcMilliDb,
    nbsSigCondEqualizeDesiredVal    NbsTcMilliDb
}

nbsSigCondEqualizeEntry      OBJECT-TYPE
    SYNTAX      NbsSigCondEqualizeEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "Equalization parameters and settings"
    INDEX { nbsSigCondEqualizeIfIndex }
    ::= { nbsSigCondEqualizeTable 1 }

nbsSigCondEqualizeIfIndex   OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The Mib2 ifIndex of this channel's WDM port"
    ::= { nbsSigCondEqualizeEntry 1 }

nbsSigCondEqualizeState  OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported (1),
        disabled     (2),
        enabled      (3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "Used to enable or disable channel equalization on this port.

        The value disabled(2) disables the feature.  No attempt to
        equalize power levels will be made, and no equalization events
        will be triggered.

        The value enabled(3) enables the feature.  A best-effort
        attempt to keep the port signal within the
        nbsSigCondEqualizeDesired range will be made.  Equalization
        events will be triggered if the power cannot be kept within
        the nbsSigCondEqualizeDesired range.

        If this port does not support equalization, this object will
        report notSupported (1), and any SET requests to this object
        will be rejected."
    DEFVAL { disabled }
    ::= { nbsSigCondEqualizeEntry 10 }

nbsSigCondEqualizeLimitMin OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The lowest channel TxPower setting the equalizer supports"
    ::= { nbsSigCondEqualizeEntry 11 }

nbsSigCondEqualizeLimitMax OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The highest channel TxPower setting the equalizer supports"
    ::= { nbsSigCondEqualizeEntry 12 }

nbsSigCondEqualizeDesiredMin OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The user-settable minimum channel TxPower level.

        Allowed values are from nbsSigCondEqualizeLimitMin to
        nbsSigCondEqualizeLimitMax, inclusive.

        Equalizer must attempt to maintain the channels' signal at or
        above this level.  The event nbsSigCondEventEqualizeTooLow
        indicates that it was unable to meet the desired minimum
        signal strength for a given channel."
        DEFVAL { -50000 }
    ::= { nbsSigCondEqualizeEntry 21 }

nbsSigCondEqualizeDesiredMax OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The user-settable maximum channel TxPower level.

        Allowed values are from nbsSigCondEqualizeLimitMin to
        nbsSigCondEqualizeLimitMax, inclusive.

        Equalizer must attempt to maintain the channels' signal at or
        below this level.  The event nbsSigCondEventEqualizeTooHigh
        indicates that it was unable to meet the desired maximum
        signal strength for a given channel."
        DEFVAL { 0 }
    ::= { nbsSigCondEqualizeEntry 22 }

nbsSigCondEqualizeDesiredVal OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "Equalizer must attempt to maintain the channels' signal at
        this level.

        Allowed values are from nbsSigCondEqualizeLimitMin to
        nbsSigCondEqualizeLimitMax, inclusive."
        DEFVAL { -25000 }
    ::= { nbsSigCondEqualizeEntry 23 }



 -- *******************************************************************
 --
-- the nbsSigCondRedundTable
--
-- *******************************************************************

nbsSigCondRedundTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The number of entries in nbsSigCondRedund."
    ::= { nbsSigCondRedundGrp 1 }

nbsSigCondRedundTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSigCondRedundEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "List of ports supporting power level redundancy."
    ::= { nbsSigCondRedundGrp 2 }

NbsSigCondRedundEntry ::= SEQUENCE {
    nbsSigCondRedundIfIndex       InterfaceIndex,
    nbsSigCondRedundLimitMin      NbsTcMilliDb,
    nbsSigCondRedundLimitMax      NbsTcMilliDb,
    nbsSigCondRedundDesiredMin    NbsTcMilliDb,
    nbsSigCondRedundDesiredMax    NbsTcMilliDb
}

nbsSigCondRedundEntry      OBJECT-TYPE
    SYNTAX      NbsSigCondRedundEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "Redundancy  settings"
    INDEX { nbsSigCondRedundIfIndex }
    ::= { nbsSigCondRedundTable 1 }

nbsSigCondRedundIfIndex   OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The Mib2 ifIndex of this channel's Redundancy port"
    ::= { nbsSigCondRedundEntry 1 }

nbsSigCondRedundLimitMin OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The lowest channel Power setting"
    ::= { nbsSigCondRedundEntry 5 }

nbsSigCondRedundLimitMax OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The highest channel Power setting"
    ::= { nbsSigCondRedundEntry 8 }

nbsSigCondRedundDesiredMin OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The lowest channel Power setting before the redundancy kicks in"
    ::= { nbsSigCondRedundEntry 10 }

nbsSigCondRedundDesiredMax OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The highest channel Power setting before the redundancy kicks in"
    ::= { nbsSigCondRedundEntry 15 }



-- *******************************************************************
--
-- the nbsSigCondPortTable
--
-- *******************************************************************

nbsSigCondPortTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of entries in nbsSigCondPortTable."
        ::= { nbsSigCondPortGrp 1 }

nbsSigCondPortTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF NbsSigCondPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "Table of VOA and VGA ports."
        ::= { nbsSigCondPortGrp 2 }

NbsSigCondPortEntry ::= SEQUENCE {
        nbsSigCondPortIfIndex      InterfaceIndex,
        nbsSigCondPortRxPower      INTEGER,
        nbsSigCondPortTxPower      INTEGER,
        nbsSigCondPortReflection   INTEGER,
        nbsSigCondPortRxPowerMin   INTEGER,
        nbsSigCondPortRxPowerMax   INTEGER,
        nbsSigCondPortNoiseFigure  INTEGER
}

nbsSigCondPortEntry      OBJECT-TYPE
        SYNTAX      NbsSigCondPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          ""
        INDEX { nbsSigCondPortIfIndex }
        ::= { nbsSigCondPortTable 1 }

nbsSigCondPortIfIndex   OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The Mib2 ifIndex of the port"
        ::= { nbsSigCondPortEntry 1 }

nbsSigCondPortRxPower OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured receiver power, in millidecibels (mdBm).
           User interfaces should show this in decibels (dBm).
           Not supported value:  -100000"
        ::= { nbsSigCondPortEntry 2 }

nbsSigCondPortTxPower OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured transmitter power, in millidecibels (mdBm).
           User interfaces should show this in decibels (dBm).
           Not supported value:  -100000"
        ::= { nbsSigCondPortEntry 3 }

nbsSigCondPortReflection OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured back reflection power, in millidecibels (mdBm).
           User interfaces should show this in decibels (dBm).
           Not supported value:  -100000"
        ::= { nbsSigCondPortEntry 4}

nbsSigCondPortRxPowerMin OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured minimum receiver power, in millidecibels (mdBm).
           User interfaces should show this in decibels (dBm).
           Not supported value:  -100000"
        ::= { nbsSigCondPortEntry 5 }

nbsSigCondPortRxPowerMax OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured maximum receiver power, in millidecibels (mdBm).
           User interfaces should show this in decibels (dBm).
           Not supported value:  -100000"
        ::= { nbsSigCondPortEntry 6 }

nbsSigCondPortNoiseFigure OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Measured Noise Figure value, in millidecibels (mdB).
           User interfaces should show this in decibels (dB).
           Not supported value: -100000"
        ::= { nbsSigCondPortEntry 7 }



-- *******************************************************************
--
-- the nbsSigCondChannelGrp
--
-- *******************************************************************

nbsSigCondChannelTableSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The number of entries in nbsSigCondChannelTable."
    ::= { nbsSigCondChannelGrp 1 }

nbsSigCondChannelTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSigCondChannelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "WDM channels within a mux port"
        ::= { nbsSigCondChannelGrp 2 }

nbsSigCondChannelEntry      OBJECT-TYPE
    SYNTAX      NbsSigCondChannelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       ""
    INDEX { nbsSigCondChannelIfIndex, nbsSigCondChannelCenterline }
    ::= { nbsSigCondChannelTable 1 }

NbsSigCondChannelEntry ::= SEQUENCE {
    nbsSigCondChannelIfIndex      InterfaceIndex,
    nbsSigCondChannelCenterline   NbsTcMHz,
    nbsSigCondChannelRxPower      NbsTcMilliDb,
    nbsSigCondChannelTxPower      NbsTcMilliDb,
    nbsSigCondChannelTxAttenu     NbsTcMilliDb,
    nbsSigCondChannelRxAttenu     NbsTcMilliDb
}

nbsSigCondChannelIfIndex   OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
       "The Mib2 ifIndex of this channel's mux port"
    ::= { nbsSigCondChannelEntry 1 }

nbsSigCondChannelCenterline   OBJECT-TYPE
    SYNTAX      NbsTcMHz
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The center frequency of this channel, in MHz"
    ::= { nbsSigCondChannelEntry 2 }

nbsSigCondChannelRxPower   OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The dynamically measured or calculated receive signal strength"
    ::= { nbsSigCondChannelEntry 11 }

nbsSigCondChannelTxPower   OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The dynamically measured or calculated transmit signal
        strength"
    ::= { nbsSigCondChannelEntry 12 }

nbsSigCondChannelTxAttenu   OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The actual attenuation applied to this channel, possibly
        representing changes made by the equalization process if
        nbsSigCondEqualizeState is enabled for this IfIndex."
    ::= { nbsSigCondChannelEntry 14 }

nbsSigCondChannelRxAttenu   OBJECT-TYPE
    SYNTAX      NbsTcMilliDb
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The actual attenuation applied to this channel, possibly
        representing changes made by the equalization process if
        nbsSigCondEqualizeState is enabled for this IfIndex."
    ::= { nbsSigCondChannelEntry 15 }

-- *******************************************************************
--
-- the nbsSigCondVodPortTable
--
-- *******************************************************************

nbsSigCondVodPortTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of ports supporting variable optical dispersion
           at the port level."
        ::= { nbsSigCondVodPortGrp 1 }

nbsSigCondVodPortTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF NbsSigCondVodPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "List of ports supporting variable optical attenuation at the
           port level."
        ::= { nbsSigCondVodPortGrp 2 }

NbsSigCondVodPortEntry ::= SEQUENCE {
        nbsSigCondVodPortIfIndex                      InterfaceIndex,
        nbsSigCondVodPortDispersionMin                INTEGER,
        nbsSigCondVodPortDispersionMax                INTEGER,
        nbsSigCondVodPortDispersionAdmin              INTEGER,
        nbsSigCondVodPortDispersionOper               INTEGER,
        nbsSigCondVodPortDispersionGridOffsetCenter   INTEGER,
        nbsSigCondVodPortDispersionGridOffsetMin      INTEGER,
        nbsSigCondVodPortDispersionGridOffsetMax      INTEGER,
        nbsSigCondVodPortDispersionGridOffsetStep     INTEGER,
        nbsSigCondVodPortDispersionGridOffsetExponent INTEGER,
        nbsSigCondVodPortDispersionGridOffsetAdmin    INTEGER,
        nbsSigCondVodPortDispersionGridOffsetOper     INTEGER
}

nbsSigCondVodPortEntry      OBJECT-TYPE
        SYNTAX      NbsSigCondVodPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          ""
        INDEX { nbsSigCondVodPortIfIndex }
        ::= { nbsSigCondVodPortTable 1 }

nbsSigCondVodPortIfIndex   OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "The Mib2 ifIndex of the dispersion compensation port."
        ::= { nbsSigCondVodPortEntry 1 }

nbsSigCondVodPortDispersionMin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Minimum allowed dispersion compensation in ps/nm.

           Not supported value: 0x80000000"

        DEFVAL { 0 }
        ::= { nbsSigCondVodPortEntry 2 }

nbsSigCondVodPortDispersionMax OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Maximum allowed dispersion compensation in ps/nm.

           Not supported value: 0x80000000"

        DEFVAL { 0 }
        ::= { nbsSigCondVodPortEntry 3 }

nbsSigCondVodPortDispersionAdmin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "Desired dispersion compensation in ps/nm.

           Not supported value: 0x80000000"

        DEFVAL { 0 }
        ::= { nbsSigCondVodPortEntry 4 }

nbsSigCondVodPortDispersionOper OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "Actual dispersion in ps/nm

           Not supported value: 0x80000000"

        DEFVAL { 0 }
        ::= { nbsSigCondVodPortEntry 5}

nbsSigCondVodPortDispersionGridOffsetCenter OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The center frequency of the offset, in GigaHertz
           (GHz), unless FreqExponent != 9.

           Not supported value: 0"

        ::= { nbsSigCondVodPortEntry 10 }

nbsSigCondVodPortDispersionGridOffsetMin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "In GigaHertz (GHz), unless FreqExponent != 9.

           Not supported value: 0x80000000"

        DEFVAL { -100 }
        ::= { nbsSigCondVodPortEntry 11 }

nbsSigCondVodPortDispersionGridOffsetMax OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "In GigaHertz (GHz), unless FreqExponent != 9.

           Not supported value: 0x80000000"

        DEFVAL { 100 }
        ::= { nbsSigCondVodPortEntry 12 }

nbsSigCondVodPortDispersionGridOffsetStep OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The spacing of the allowable grid offsets that this port
           supports, in GigaHertz (GHz), unless FreqExponent != 9.

           Not supported value: 0"

        DEFVAL { 1 }
        ::= { nbsSigCondVodPortEntry 13 }

nbsSigCondVodPortDispersionGridOffsetExponent OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The exponent of all the GridOffset values (including
           GridOffsetStep).

           9 (the default) indicates all units are in GigaHertz (GHz)."

        DEFVAL { 9 }
        ::= { nbsSigCondVodPortEntry 14 }

nbsSigCondVodPortDispersionGridOffsetAdmin OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "In GigaHertz (GHz), unless FreqExponent != 9.

           Not supported value: 0x80000000"

        ::= { nbsSigCondVodPortEntry 15 }

nbsSigCondVodPortDispersionGridOffsetOper OBJECT-TYPE
        SYNTAX      INTEGER (-100000..100000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "In GigaHertz (GHz), unless FreqExponent != 9.

           Not supported value: 0x80000000"

        ::= { nbsSigCondVodPortEntry 16 }


-- *******************************************************************
--
-- the nbsSigCondEvent group
--
-- *******************************************************************

nbsSigCondEventEqualizeOk  NOTIFICATION-TYPE
    OBJECTS  { nbsSigCondEqualizeIfIndex, ifAlias,
        nbsSigCondChannelCenterline, nbsSigCondChannelTxPower,
        nbsSigCondEqualizeDesiredMin, nbsSigCondEqualizeDesiredMax }
    STATUS      current
    DESCRIPTION
       "Sent when equalizer becomes able to maintain TxPower within the
        user-specified nbsSigCondEqualizeDesired range.

        This Notification is of severity ERROR, which means it should
        be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set
        to a severity worse than error(3)."
    ::= { nbsSigCondEvent 20 }

nbsSigCondEventEqualizeTooLow  NOTIFICATION-TYPE
    OBJECTS  { nbsSigCondEqualizeIfIndex, ifAlias,
        nbsSigCondChannelCenterline, nbsSigCondChannelTxPower,
        nbsSigCondEqualizeDesiredMin }
    STATUS      current
    DESCRIPTION
       "Sent when equalizer becomes unable to maintain TxPower at or
        above nbsSigCondEqualizeDesiredMin.

        This Notification is of severity ERROR, which means it should
        be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set
        to a severity worse than error(3)."
    ::= { nbsSigCondEvent 21}

nbsSigCondEventEqualizeTooHigh  NOTIFICATION-TYPE
    OBJECTS  { nbsSigCondEqualizeIfIndex, ifAlias,
        nbsSigCondChannelCenterline, nbsSigCondChannelTxPower,
        nbsSigCondEqualizeDesiredMax }
    STATUS      current
    DESCRIPTION
       "Sent when equalizer becomes unable to maintain TxPower at or
        below nbsSigCondEqualizeDesiredMax.

        This Notification is of severity ERROR, which means it should
        be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set
        to a severity worse than error(3)."
    ::= { nbsSigCondEvent 22 }

END