NBS-SIGCOND-MIB DEFINITIONS ::= BEGIN IMPORTS Unsigned32, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY FROM SNMPv2-SMI InterfaceIndex, ifAlias FROM IF-MIB nbs, NbsTcMilliDb, NbsTcMHz FROM NBS-MIB; nbsSigCondMib MODULE-IDENTITY LAST-UPDATED "201707270000Z" -- July 27, 2017 ORGANIZATION "NBS" CONTACT-INFO "For technical support, please contact your service channel" DESCRIPTION "Signal Conditioning mib" ::= { nbs 227 } -- ******************************************************************* -- NBS-SIGCOND-MIB local defines -- ******************************************************************* nbsSigCondVoaPortGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Variable Optical Attenuation at the port level." ::= { nbsSigCondMib 1 } nbsSigCondVoaChannelGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Variable Optical Attenuation at the channel level." ::= { nbsSigCondMib 2} nbsSigCondRamanGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Raman amplifier information for the port." ::= { nbsSigCondMib 3 } nbsSigCondEqualizeGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Management info for equalizing power levels among channels within a WDM port" ::= { nbsSigCondMib 20 } nbsSigCondRedundGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Management info for power level based redundancy" ::= { nbsSigCondMib 30 } nbsSigCondPortGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Power readings from the port." ::= { nbsSigCondMib 40 } nbsSigCondChannelGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Signal info for WDM channels within a WDM port" ::= { nbsSigCondMib 50 } nbsSigCondVodPortGrp OBJECT-IDENTITY STATUS current DESCRIPTION "Dispersion compensation at the port level." ::= { nbsSigCondMib 60 } nbsSigCondTraps OBJECT-IDENTITY STATUS current DESCRIPTION "SNMP Traps or Notifications" ::= { nbsSigCondMib 200 } nbsSigCondEvent OBJECT-IDENTITY STATUS current DESCRIPTION "SNMP Traps or Notifications" ::= { nbsSigCondTraps 0 } -- ******************************************************************* -- -- the nbsSigCondVoaPortTable -- -- ******************************************************************* nbsSigCondVoaPortTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ports supporting variable optical attenuation at the port level." ::= { nbsSigCondVoaPortGrp 1 } nbsSigCondVoaPortTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondVoaPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of ports supporting variable optical attenuation at the port level." ::= { nbsSigCondVoaPortGrp 2 } NbsSigCondVoaPortEntry ::= SEQUENCE { nbsSigCondVoaPortIfIndex InterfaceIndex, nbsSigCondVoaPortRxAttenuAdmin INTEGER, nbsSigCondVoaPortRxAttenuOper INTEGER, nbsSigCondVoaPortTxAttenuAdmin INTEGER, nbsSigCondVoaPortTxAttenuOper INTEGER } nbsSigCondVoaPortEntry OBJECT-TYPE SYNTAX NbsSigCondVoaPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { nbsSigCondVoaPortIfIndex } ::= { nbsSigCondVoaPortTable 1 } nbsSigCondVoaPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of the attenuable port." ::= { nbsSigCondVoaPortEntry 1 } nbsSigCondVoaPortRxAttenuAdmin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Persistent and immediately updated. User-requested attenuation to be applied to received signal, expressed in millidecibels (mdB). Not supported value: -200000" DEFVAL { 0 } ::= { nbsSigCondVoaPortEntry 2 } nbsSigCondVoaPortRxAttenuOper OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Attenuation actually being applied to received signal, in millidecibels (mdB). Not supported value: -200000" DEFVAL { 0 } ::= { nbsSigCondVoaPortEntry 3 } nbsSigCondVoaPortTxAttenuAdmin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Persistent and immediately updated. User-requested attenuation to be applied before transmitting signal, expressed in millidecibels (mdB). Not supported value: -200000" DEFVAL { 0 } ::= { nbsSigCondVoaPortEntry 4 } nbsSigCondVoaPortTxAttenuOper OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Attenuation actually being applied before transmitting signal, in millidecibels (mdB). Not supported value: -200000" DEFVAL { 0 } ::= { nbsSigCondVoaPortEntry 5} -- ******************************************************************* -- -- the nbsSigCondVoaChannelTbl -- -- ******************************************************************* nbsSigCondVoaChannelRangeTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of mux ports supporting variable optical attenuation at the channel level." ::= { nbsSigCondVoaChannelGrp 1 } nbsSigCondVoaChannelRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondVoaChannelRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel attenuation values supported on this port." ::= { nbsSigCondVoaChannelGrp 2 } NbsSigCondVoaChannelRangeEntry ::= SEQUENCE { nbsSigCondVoaChannelRangeIfIndex InterfaceIndex, nbsSigCondVoaChannelRangeMin NbsTcMilliDb, nbsSigCondVoaChannelRangeMax NbsTcMilliDb, nbsSigCondVoaChannelRangeIncr NbsTcMilliDb } nbsSigCondVoaChannelRangeEntry OBJECT-TYPE SYNTAX NbsSigCondVoaChannelRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { nbsSigCondVoaChannelRangeIfIndex } ::= { nbsSigCondVoaChannelRangeTable 1 } nbsSigCondVoaChannelRangeIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of the mux port." ::= { nbsSigCondVoaChannelRangeEntry 1 } nbsSigCondVoaChannelRangeMin OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest channel attenuation value supported by this mux port, expressed in millidecibels (mdB). This is the smallest attenuation supported." DEFVAL { 0 } ::= { nbsSigCondVoaChannelRangeEntry 2 } nbsSigCondVoaChannelRangeMax OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The greatest channel attenuation value supported by this mux port, expressed in millidecibels (mdB). This is the largest attenuation supported." DEFVAL { 0 } ::= { nbsSigCondVoaChannelRangeEntry 3 } nbsSigCondVoaChannelRangeIncr OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The precision of the VOA, expressed in millidecibels (mdB). The minimum difference between attenuation values." DEFVAL { 0 } ::= { nbsSigCondVoaChannelRangeEntry 4 } -- ******************************************************************* -- -- the nbsSigCondRamanTable -- -- ******************************************************************* nbsSigCondRamanTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of raman ports in this system." ::= { nbsSigCondRamanGrp 1 } nbsSigCondRamanTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondRamanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Raman readings." ::= { nbsSigCondRamanGrp 2 } NbsSigCondRamanEntry ::= SEQUENCE { nbsSigCondRamanIfIndex InterfaceIndex, nbsSigCondRamanPumpPwrAdmin INTEGER, nbsSigCondRamanPumpPwrOper INTEGER } nbsSigCondRamanEntry OBJECT-TYPE SYNTAX NbsSigCondRamanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Raman readings on an individual port." INDEX { nbsSigCondRamanIfIndex } ::= { nbsSigCondRamanTable 1 } nbsSigCondRamanIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of the Raman port" ::= { nbsSigCondRamanEntry 1 } nbsSigCondRamanPumpPwrAdmin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Persistent and immediately updated. User-requested pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1" ::= { nbsSigCondRamanEntry 2 } nbsSigCondRamanPumpPwrOper OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Agent reported pump power, in microwatts (uW). User interfaces should show this in millWatts (mW). Not supported value: -1" ::= { nbsSigCondRamanEntry 3 } -- ******************************************************************* -- -- the nbsSigCondEqualizeTable -- -- ******************************************************************* nbsSigCondEqualizeTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in nbsSigCondEqualizeTable." ::= { nbsSigCondEqualizeGrp 1 } nbsSigCondEqualizeTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondEqualizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of WDM ports supporting power level equalization." ::= { nbsSigCondEqualizeGrp 2 } NbsSigCondEqualizeEntry ::= SEQUENCE { nbsSigCondEqualizeIfIndex InterfaceIndex, nbsSigCondEqualizeState INTEGER, nbsSigCondEqualizeLimitMin NbsTcMilliDb, nbsSigCondEqualizeLimitMax NbsTcMilliDb, nbsSigCondEqualizeDesiredMin NbsTcMilliDb, nbsSigCondEqualizeDesiredMax NbsTcMilliDb, nbsSigCondEqualizeDesiredVal NbsTcMilliDb } nbsSigCondEqualizeEntry OBJECT-TYPE SYNTAX NbsSigCondEqualizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Equalization parameters and settings" INDEX { nbsSigCondEqualizeIfIndex } ::= { nbsSigCondEqualizeTable 1 } nbsSigCondEqualizeIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The Mib2 ifIndex of this channel's WDM port" ::= { nbsSigCondEqualizeEntry 1 } nbsSigCondEqualizeState OBJECT-TYPE SYNTAX INTEGER { notSupported (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable or disable channel equalization on this port. The value disabled(2) disables the feature. No attempt to equalize power levels will be made, and no equalization events will be triggered. The value enabled(3) enables the feature. A best-effort attempt to keep the port signal within the nbsSigCondEqualizeDesired range will be made. Equalization events will be triggered if the power cannot be kept within the nbsSigCondEqualizeDesired range. If this port does not support equalization, this object will report notSupported (1), and any SET requests to this object will be rejected." DEFVAL { disabled } ::= { nbsSigCondEqualizeEntry 10 } nbsSigCondEqualizeLimitMin OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest channel TxPower setting the equalizer supports" ::= { nbsSigCondEqualizeEntry 11 } nbsSigCondEqualizeLimitMax OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The highest channel TxPower setting the equalizer supports" ::= { nbsSigCondEqualizeEntry 12 } nbsSigCondEqualizeDesiredMin OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-write STATUS current DESCRIPTION "The user-settable minimum channel TxPower level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclusive. Equalizer must attempt to maintain the channels' signal at or above this level. The event nbsSigCondEventEqualizeTooLow indicates that it was unable to meet the desired minimum signal strength for a given channel." DEFVAL { -50000 } ::= { nbsSigCondEqualizeEntry 21 } nbsSigCondEqualizeDesiredMax OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-write STATUS current DESCRIPTION "The user-settable maximum channel TxPower level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclusive. Equalizer must attempt to maintain the channels' signal at or below this level. The event nbsSigCondEventEqualizeTooHigh indicates that it was unable to meet the desired maximum signal strength for a given channel." DEFVAL { 0 } ::= { nbsSigCondEqualizeEntry 22 } nbsSigCondEqualizeDesiredVal OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-write STATUS current DESCRIPTION "Equalizer must attempt to maintain the channels' signal at this level. Allowed values are from nbsSigCondEqualizeLimitMin to nbsSigCondEqualizeLimitMax, inclusive." DEFVAL { -25000 } ::= { nbsSigCondEqualizeEntry 23 } -- ******************************************************************* -- -- the nbsSigCondRedundTable -- -- ******************************************************************* nbsSigCondRedundTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in nbsSigCondRedund." ::= { nbsSigCondRedundGrp 1 } nbsSigCondRedundTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondRedundEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of ports supporting power level redundancy." ::= { nbsSigCondRedundGrp 2 } NbsSigCondRedundEntry ::= SEQUENCE { nbsSigCondRedundIfIndex InterfaceIndex, nbsSigCondRedundLimitMin NbsTcMilliDb, nbsSigCondRedundLimitMax NbsTcMilliDb, nbsSigCondRedundDesiredMin NbsTcMilliDb, nbsSigCondRedundDesiredMax NbsTcMilliDb } nbsSigCondRedundEntry OBJECT-TYPE SYNTAX NbsSigCondRedundEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Redundancy settings" INDEX { nbsSigCondRedundIfIndex } ::= { nbsSigCondRedundTable 1 } nbsSigCondRedundIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The Mib2 ifIndex of this channel's Redundancy port" ::= { nbsSigCondRedundEntry 1 } nbsSigCondRedundLimitMin OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest channel Power setting" ::= { nbsSigCondRedundEntry 5 } nbsSigCondRedundLimitMax OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The highest channel Power setting" ::= { nbsSigCondRedundEntry 8 } nbsSigCondRedundDesiredMin OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-write STATUS current DESCRIPTION "The lowest channel Power setting before the redundancy kicks in" ::= { nbsSigCondRedundEntry 10 } nbsSigCondRedundDesiredMax OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-write STATUS current DESCRIPTION "The highest channel Power setting before the redundancy kicks in" ::= { nbsSigCondRedundEntry 15 } -- ******************************************************************* -- -- the nbsSigCondPortTable -- -- ******************************************************************* nbsSigCondPortTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in nbsSigCondPortTable." ::= { nbsSigCondPortGrp 1 } nbsSigCondPortTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of VOA and VGA ports." ::= { nbsSigCondPortGrp 2 } NbsSigCondPortEntry ::= SEQUENCE { nbsSigCondPortIfIndex InterfaceIndex, nbsSigCondPortRxPower INTEGER, nbsSigCondPortTxPower INTEGER, nbsSigCondPortReflection INTEGER, nbsSigCondPortRxPowerMin INTEGER, nbsSigCondPortRxPowerMax INTEGER, nbsSigCondPortNoiseFigure INTEGER } nbsSigCondPortEntry OBJECT-TYPE SYNTAX NbsSigCondPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { nbsSigCondPortIfIndex } ::= { nbsSigCondPortTable 1 } nbsSigCondPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of the port" ::= { nbsSigCondPortEntry 1 } nbsSigCondPortRxPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000" ::= { nbsSigCondPortEntry 2 } nbsSigCondPortTxPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured transmitter power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000" ::= { nbsSigCondPortEntry 3 } nbsSigCondPortReflection OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured back reflection power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000" ::= { nbsSigCondPortEntry 4} nbsSigCondPortRxPowerMin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured minimum receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000" ::= { nbsSigCondPortEntry 5 } nbsSigCondPortRxPowerMax OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured maximum receiver power, in millidecibels (mdBm). User interfaces should show this in decibels (dBm). Not supported value: -100000" ::= { nbsSigCondPortEntry 6 } nbsSigCondPortNoiseFigure OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured Noise Figure value, in millidecibels (mdB). User interfaces should show this in decibels (dB). Not supported value: -100000" ::= { nbsSigCondPortEntry 7 } -- ******************************************************************* -- -- the nbsSigCondChannelGrp -- -- ******************************************************************* nbsSigCondChannelTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in nbsSigCondChannelTable." ::= { nbsSigCondChannelGrp 1 } nbsSigCondChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "WDM channels within a mux port" ::= { nbsSigCondChannelGrp 2 } nbsSigCondChannelEntry OBJECT-TYPE SYNTAX NbsSigCondChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { nbsSigCondChannelIfIndex, nbsSigCondChannelCenterline } ::= { nbsSigCondChannelTable 1 } NbsSigCondChannelEntry ::= SEQUENCE { nbsSigCondChannelIfIndex InterfaceIndex, nbsSigCondChannelCenterline NbsTcMHz, nbsSigCondChannelRxPower NbsTcMilliDb, nbsSigCondChannelTxPower NbsTcMilliDb, nbsSigCondChannelTxAttenu NbsTcMilliDb, nbsSigCondChannelRxAttenu NbsTcMilliDb } nbsSigCondChannelIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of this channel's mux port" ::= { nbsSigCondChannelEntry 1 } nbsSigCondChannelCenterline OBJECT-TYPE SYNTAX NbsTcMHz MAX-ACCESS read-only STATUS current DESCRIPTION "The center frequency of this channel, in MHz" ::= { nbsSigCondChannelEntry 2 } nbsSigCondChannelRxPower OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The dynamically measured or calculated receive signal strength" ::= { nbsSigCondChannelEntry 11 } nbsSigCondChannelTxPower OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The dynamically measured or calculated transmit signal strength" ::= { nbsSigCondChannelEntry 12 } nbsSigCondChannelTxAttenu OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The actual attenuation applied to this channel, possibly representing changes made by the equalization process if nbsSigCondEqualizeState is enabled for this IfIndex." ::= { nbsSigCondChannelEntry 14 } nbsSigCondChannelRxAttenu OBJECT-TYPE SYNTAX NbsTcMilliDb MAX-ACCESS read-only STATUS current DESCRIPTION "The actual attenuation applied to this channel, possibly representing changes made by the equalization process if nbsSigCondEqualizeState is enabled for this IfIndex." ::= { nbsSigCondChannelEntry 15 } -- ******************************************************************* -- -- the nbsSigCondVodPortTable -- -- ******************************************************************* nbsSigCondVodPortTableSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ports supporting variable optical dispersion at the port level." ::= { nbsSigCondVodPortGrp 1 } nbsSigCondVodPortTable OBJECT-TYPE SYNTAX SEQUENCE OF NbsSigCondVodPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of ports supporting variable optical attenuation at the port level." ::= { nbsSigCondVodPortGrp 2 } NbsSigCondVodPortEntry ::= SEQUENCE { nbsSigCondVodPortIfIndex InterfaceIndex, nbsSigCondVodPortDispersionMin INTEGER, nbsSigCondVodPortDispersionMax INTEGER, nbsSigCondVodPortDispersionAdmin INTEGER, nbsSigCondVodPortDispersionOper INTEGER, nbsSigCondVodPortDispersionGridOffsetCenter INTEGER, nbsSigCondVodPortDispersionGridOffsetMin INTEGER, nbsSigCondVodPortDispersionGridOffsetMax INTEGER, nbsSigCondVodPortDispersionGridOffsetStep INTEGER, nbsSigCondVodPortDispersionGridOffsetExponent INTEGER, nbsSigCondVodPortDispersionGridOffsetAdmin INTEGER, nbsSigCondVodPortDispersionGridOffsetOper INTEGER } nbsSigCondVodPortEntry OBJECT-TYPE SYNTAX NbsSigCondVodPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { nbsSigCondVodPortIfIndex } ::= { nbsSigCondVodPortTable 1 } nbsSigCondVodPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Mib2 ifIndex of the dispersion compensation port." ::= { nbsSigCondVodPortEntry 1 } nbsSigCondVodPortDispersionMin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum allowed dispersion compensation in ps/nm. Not supported value: 0x80000000" DEFVAL { 0 } ::= { nbsSigCondVodPortEntry 2 } nbsSigCondVodPortDispersionMax OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum allowed dispersion compensation in ps/nm. Not supported value: 0x80000000" DEFVAL { 0 } ::= { nbsSigCondVodPortEntry 3 } nbsSigCondVodPortDispersionAdmin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Desired dispersion compensation in ps/nm. Not supported value: 0x80000000" DEFVAL { 0 } ::= { nbsSigCondVodPortEntry 4 } nbsSigCondVodPortDispersionOper OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "Actual dispersion in ps/nm Not supported value: 0x80000000" DEFVAL { 0 } ::= { nbsSigCondVodPortEntry 5} nbsSigCondVodPortDispersionGridOffsetCenter OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The center frequency of the offset, in GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0" ::= { nbsSigCondVodPortEntry 10 } nbsSigCondVodPortDispersionGridOffsetMin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "In GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0x80000000" DEFVAL { -100 } ::= { nbsSigCondVodPortEntry 11 } nbsSigCondVodPortDispersionGridOffsetMax OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "In GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0x80000000" DEFVAL { 100 } ::= { nbsSigCondVodPortEntry 12 } nbsSigCondVodPortDispersionGridOffsetStep OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The spacing of the allowable grid offsets that this port supports, in GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0" DEFVAL { 1 } ::= { nbsSigCondVodPortEntry 13 } nbsSigCondVodPortDispersionGridOffsetExponent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The exponent of all the GridOffset values (including GridOffsetStep). 9 (the default) indicates all units are in GigaHertz (GHz)." DEFVAL { 9 } ::= { nbsSigCondVodPortEntry 14 } nbsSigCondVodPortDispersionGridOffsetAdmin OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "In GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0x80000000" ::= { nbsSigCondVodPortEntry 15 } nbsSigCondVodPortDispersionGridOffsetOper OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "In GigaHertz (GHz), unless FreqExponent != 9. Not supported value: 0x80000000" ::= { nbsSigCondVodPortEntry 16 } -- ******************************************************************* -- -- the nbsSigCondEvent group -- -- ******************************************************************* nbsSigCondEventEqualizeOk NOTIFICATION-TYPE OBJECTS { nbsSigCondEqualizeIfIndex, ifAlias, nbsSigCondChannelCenterline, nbsSigCondChannelTxPower, nbsSigCondEqualizeDesiredMin, nbsSigCondEqualizeDesiredMax } STATUS current DESCRIPTION "Sent when equalizer becomes able to maintain TxPower within the user-specified nbsSigCondEqualizeDesired range. This Notification is of severity ERROR, which means it should be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set to a severity worse than error(3)." ::= { nbsSigCondEvent 20 } nbsSigCondEventEqualizeTooLow NOTIFICATION-TYPE OBJECTS { nbsSigCondEqualizeIfIndex, ifAlias, nbsSigCondChannelCenterline, nbsSigCondChannelTxPower, nbsSigCondEqualizeDesiredMin } STATUS current DESCRIPTION "Sent when equalizer becomes unable to maintain TxPower at or above nbsSigCondEqualizeDesiredMin. This Notification is of severity ERROR, which means it should be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set to a severity worse than error(3)." ::= { nbsSigCondEvent 21} nbsSigCondEventEqualizeTooHigh NOTIFICATION-TYPE OBJECTS { nbsSigCondEqualizeIfIndex, ifAlias, nbsSigCondChannelCenterline, nbsSigCondChannelTxPower, nbsSigCondEqualizeDesiredMax } STATUS current DESCRIPTION "Sent when equalizer becomes unable to maintain TxPower at or below nbsSigCondEqualizeDesiredMax. This Notification is of severity ERROR, which means it should be emitted unless disabled or nbsCmmcSysTrapTblEntLevel is set to a severity worse than error(3)." ::= { nbsSigCondEvent 22 } END