ALCATEL-IND1-PORT-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, Counter64, NOTIFICATION-TYPE, MODULE-IDENTITY, TimeTicks, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex, ifInErrors, ifOutErrors FROM IF-MIB softentIND1Port, cmmEsmDrvTraps FROM ALCATEL-IND1-BASE DisplayString FROM SNMPv2-TC; alcatelIND1PortMIB MODULE-IDENTITY LAST-UPDATED "200704030000Z" ORGANIZATION "Alcatel-Lucent" CONTACT-INFO "Please consult with Customer Service to ensure the most appropriate version of this document is used with the products in question: Alcatel-Lucent, Enterprise Solutions Division (Formerly Alcatel Internetworking, Incorporated) 26801 West Agoura Road Agoura Hills, CA 91301-5122 United States Of America Telephone: North America +1 800 995 2696 Latin America +1 877 919 9526 Europe +31 23 556 0100 Asia +65 394 7933 All Other +1 818 878 4507 Electronic Mail: support@ind.alcatel.com World Wide Web: http://alcatel-lucent.com/wps/portal/enterprise File Transfer Protocol: ftp://ftp.ind.alcatel.com/pub/products/mibs" DESCRIPTION "This module describes an authoritative enterprise-specific Simple Network Management Protocol (SNMP) Management Information Base (MIB): This group contains the configuration information data for the Ethernet Switching Module. The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE" REVISION "200704030000Z" DESCRIPTION "The latest version of this MIB Module." ::= { softentIND1Port 1} alcatelIND1PortNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 0 } alcatelIND1PortMIBObjects OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 1 } alcatelIND1PortMIBConformance OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 2 } -- -- alcatelIND1PortMIBObjects -- esmConfTrap OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 1 } physicalPort OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 2 } ddmConfiguration OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 4 } ddmNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 1 } esmViolationRecovery OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 5 } esmViolationNotifications OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 2 } -- Ethernet Driver object related to Trap ********************* esmDrvTrapDrops OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Partitioned port (separated due to errors)." ::= { esmConfTrap 1 } -- Ethernet Driver Tables ***************************** -- EsmConf group. This group contains the configuration -- information data for the Ethernet Switching Module. -- Implementation of this group is mandantory. -- -- Note that this MIB can NOT be used for row creation (this -- would imply that you could override the actual physical -- characteristics of the physical card!). esmConfTable OBJECT-TYPE SYNTAX SEQUENCE OF EsmConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ESM Physical Port instances." ::= { physicalPort 1 } esmConfEntry OBJECT-TYPE SYNTAX EsmConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ESM Physical Port entry." INDEX { ifIndex } ::= { esmConfTable 1 } EsmConfEntry ::= SEQUENCE { esmPortSlot Integer32, esmPortIF Integer32, esmPortAutoSpeed INTEGER, esmPortAutoDuplexMode INTEGER, esmPortCfgSpeed INTEGER, esmPortCfgDuplexMode INTEGER, esmPortCfgIFG Integer32, esmPortPauseSlotTime Integer32, esmPortMaxFloodRate INTEGER, esmPortFloodMcastEnable INTEGER, esmPortCfgMaxFrameSize Integer32, esmPortCfgLongEnable INTEGER, esmPortCfgRuntEnable INTEGER, esmPortCfgRuntSize Integer32, esmPortCfgAutoNegotiation INTEGER, esmPortCfgCrossover INTEGER, esmPortCfgFlow INTEGER, esmPortCfgHybridActiveType INTEGER, esmPortCfgHybridMode INTEGER, esmPortOperationalHybridType INTEGER, esmPortCfgMMULowWaterMarkCellSetLimit INTEGER, esmPortCfgMMUDynamicCellSetLimit INTEGER, esmPortViolationBitMap BITS, esmPortViolationClearAll INTEGER, esmPortFloodBcastEnable INTEGER, esmPortFloodUnknownUcastEnable INTEGER, esmPortMaxUnknownUcastFloodRate INTEGER, esmPortMaxMcastFloodRate INTEGER, esmPortMaxFloodRateLimit Integer32, esmPortMaxUnknownUcastFloodRateLimit Integer32, esmPortMaxMcastFloodRateLimit Integer32, esmPortCfgSFPType DisplayString } esmPortSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical Slot number for this Ethernet Port. Slot number has been added to be used by the private Trap." ::= { esmConfEntry 1 } esmPortIF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The on-board interface number for this Ethernet Port. Port Number has been added to be used by the private Trap." ::= { esmConfEntry 2 } esmPortAutoSpeed OBJECT-TYPE SYNTAX INTEGER { speed100(1), speed10(2), speedAuto(3), unknown(4), speed1000(5), speed10000(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The automatically detected port line speed of this ESM port." ::= { esmConfEntry 3 } esmPortAutoDuplexMode OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3), unknown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The automatically detected port duplex mode of this ESM port. Note: GigaEthernet supports only Full duplex mode. Default value for 10/100 = Half duplex mode." ::= { esmConfEntry 4 } esmPortCfgSpeed OBJECT-TYPE SYNTAX INTEGER { speed100(1), speed10(2), speedAuto(3), speed1000(5), speed10000(6), speedMax100(8), speedMax1000(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configured port line speed of this ESM port." ::= { esmConfEntry 5 } esmPortCfgDuplexMode OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configured port duplex mode of this ESM port. Note: GigaEthernet support only full-duplex." ::= { esmConfEntry 6 } esmPortCfgIFG OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Contains the setting of Inter-Frame Gap (IFG), in bytes for receive and transmit. The range is from 9 to 12 bytes. Note: The default value changed according to the Port type Default Bandwidth value 12 bytes 10Mbps 9600 nsec 100Mbps 960 nsec 1Gbps 96 nsec 10Gbps 9.6 nsec." DEFVAL { 12 } ::= { esmConfEntry 7 } esmPortPauseSlotTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the number of microseconds the other end-station waits after the reception of a pause frame. Note: Pause Flow control is not available for 10Mbps. For 100Mbps, the possible value range is 5120 nanosec to 0.3 sec. For 1Gbps, the possible value range is 512 nanosec to 0.03 sec." ::= { esmConfEntry 8 } esmPortMaxFloodRate OBJECT-TYPE SYNTAX INTEGER { mbps(1), percentage(2), pps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Broadcast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also." DEFVAL { mbps } ::= { esmConfEntry 9 } esmPortFloodMcastEnable OBJECT-TYPE SYNTAX INTEGER { disableMulticastFlood(2), enableMulticastFlood(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable the maximum flood rate for multicast." DEFVAL { disableMulticastFlood } ::= { esmConfEntry 10 } esmPortCfgMaxFrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the value of the maximum frame size allow. For 10/100: It is a range between 1518(untagged) and 1553 bytes. For GigaEthernet: It is a range between 1518 and 10240 bytes.(OS7700,OS7800,OS8800) It is a range between 1518 and 9216 bytes.(OS6800)" ::= { esmConfEntry 11 } esmPortCfgLongEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to change the maximun Frame size. Note: It is not configurable for 10/100 Ethernet port." DEFVAL { disable } ::= { esmConfEntry 12 } esmPortCfgRuntEnable OBJECT-TYPE SYNTAX INTEGER { disable(2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to change the minimum Frame size." DEFVAL { disable } ::= { esmConfEntry 13 } esmPortCfgRuntSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the value of the minimum frame size allow per ports. The range is 0 to 64." DEFVAL { 64 } ::= { esmConfEntry 14 } esmPortCfgAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to enable or disable the port auto negotiation." DEFVAL { disable } ::= { esmConfEntry 15 } esmPortCfgCrossover OBJECT-TYPE SYNTAX INTEGER { mdi(1), mdix(2), auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to configure port crossover." DEFVAL { auto } ::= { esmConfEntry 16 } esmPortCfgFlow OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use the dot3PauseAdminMode from the standard MIB to configure the flow control." DEFVAL { disable } ::= { esmConfEntry 17 } esmPortCfgHybridActiveType OBJECT-TYPE SYNTAX INTEGER { notapplicable(0), fiber(1), copper(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to hybrid ports . It indicates configured active media type.(the operational media type may be different if esmPortCfgHybridMode is configured to be preferredFiber or preferredCopper) For non hybrid ports notapplicable is returned as a status." ::= { esmConfEntry 18 } esmPortCfgHybridMode OBJECT-TYPE SYNTAX INTEGER { notapplicable(0), preferredCopper(1), forcedCopper(2), preferredFiber(3), forcedFiber(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is only applicable to hybrid ports. This allows the user the user to configure the media type with which the port should come up. The user can configure the port to come as copper only or fiber only or either fiber/copper (with preference to one of them)." DEFVAL { preferredFiber } ::= { esmConfEntry 19 } esmPortOperationalHybridType OBJECT-TYPE SYNTAX INTEGER { none(0), fiber(1), copper(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to hybrid ports . It indicates the actual media type that has link up and is or will be passing traffic. If link is not present the object will return none(0) value." ::= { esmConfEntry 20 } esmPortCfgMMULowWaterMarkCellSetLimit OBJECT-TYPE SYNTAX INTEGER (0..16383) MAX-ACCESS read-write STATUS current DESCRIPTION " Per-port-per-CoS Head of Line blocking cell limits. Range is 0 - 16383 Firebolt register Offset: 0x006pp30 - 0x37 Bits: 13:0 CellSetLimit , Default: 0x0100 This setting allocates the guaranteed cells for one port's CoSx queue. After cell count over this limit, it will start using dynamic cells in port dynamic space." DEFVAL { 256 } ::= { esmConfEntry 21 } esmPortCfgMMUDynamicCellSetLimit OBJECT-TYPE SYNTAX INTEGER (0..16383) MAX-ACCESS read-write STATUS current DESCRIPTION "Per-egress port cell-based dynamic (shared buffer pool) memory usage drop and resume thresholds. This sets the limit for which the eight CoS-Qs within a port may share once the LWMCOSCELL limit is exceeded. Range is 0 - 16383 Firebolt register Offset: 0x006pp040 Bits: 13:0 Dynamic CellSetLimit , Chip Default: 0x0400 (1024). The system default value for Dynamic CellSetLimit is 0x100 (256)." DEFVAL { 1024 } ::= { esmConfEntry 22 } esmPortViolationBitMap OBJECT-TYPE SYNTAX BITS{ bEniSecurityBlockPortENI(0), -- ENI App blocking this port bEniSecurityBlockPortSTP(1), -- STP App blocking this port bEniSecurityBlockPortSL(2), -- SL App blocking this port bEniSecurityBlockPortQoS(3), -- QoS App blocking this port bEniSecurityBlockPortUDLD(4), -- UDLD App blocking this port bEniSecurityBlockPortETHBLK(5) -- ETHBLK App blocking this port } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit map that identifies the set of Application that have blocked a port as a result of a particular violation " ::= { esmConfEntry 23 } esmPortViolationClearAll OBJECT-TYPE SYNTAX INTEGER(0) MAX-ACCESS read-write STATUS current DESCRIPTION "Clear all port vioaltion " ::= { esmConfEntry 24 } esmPortFloodBcastEnable OBJECT-TYPE SYNTAX INTEGER { disableBcastFlood(2), enableBcastFlood(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable the maximum flood rate for Broadcast." DEFVAL { enableBcastFlood } ::= { esmConfEntry 25 } esmPortFloodUnknownUcastEnable OBJECT-TYPE SYNTAX INTEGER { disableUnknownUcastFlood(2), enableUnknownUcastFlood(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable the maximum flood rate for unknown unicast." DEFVAL { enableUnknownUcastFlood } ::= { esmConfEntry 26 } esmPortMaxUnknownUcastFloodRate OBJECT-TYPE SYNTAX INTEGER { mbps(1), percentage(2), pps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Unknown-Unicast flood threshold type. To set the type, set esmPortMaxUnknownUcastFloodRateLimit also" DEFVAL { mbps } ::= { esmConfEntry 27 } esmPortMaxMcastFloodRate OBJECT-TYPE SYNTAX INTEGER { mbps(1), percentage(2), pps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Multicast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also." DEFVAL { mbps } ::= { esmConfEntry 28 } esmPortMaxFloodRateLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the maximum broadcast flood limit. The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxFloodRate first" ::= { esmConfEntry 29 } esmPortMaxUnknownUcastFloodRateLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the maximum unknown-unicast flood limit The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxUnknownUcastFloodRate first" ::= { esmConfEntry 30 } esmPortMaxMcastFloodRateLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the maximum multicast flood limit The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxMcastFloodRate first" ::= { esmConfEntry 31 } esmPortCfgSFPType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to fiber ports. The string indicates the type of SFP/GBIC of active media." ::= { esmConfEntry 32 } -- Ethernet Port Mode Tables ***************************** -- EsmPortMode group. This group contains the configuration -- information data for the Ethernet Switching Module. -- Implementation of this group is mandantory. -- -- Note that this MIB can NOT be used for row creation (this -- would imply that you could override the actual physical -- characteristics of the physical card!). esmPortModeTable OBJECT-TYPE SYNTAX SEQUENCE OF EsmPortModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ESM Physical Port Mode instances." ::= { physicalPort 6 } esmPortModeEntry OBJECT-TYPE SYNTAX EsmPortModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ESM Physical Port Mode entry." INDEX { esmPortModeIndex } ::= { esmPortModeTable 1 } EsmPortModeEntry ::= SEQUENCE { esmPortModeIndex INTEGER, esmPortRunningMode INTEGER, esmPortSavedMode INTEGER } esmPortModeIndex OBJECT-TYPE SYNTAX INTEGER (1001..8128) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Valid ni/port values" ::= { esmPortModeEntry 1 } esmPortRunningMode OBJECT-TYPE SYNTAX INTEGER { uplink(1), stackable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Currently configured Etna port 25,26 as 10G uplink user port or stacking port. Default is uplink 10G port. User can not set the current mode." ::= { esmPortModeEntry 2 } esmPortSavedMode OBJECT-TYPE SYNTAX INTEGER { uplink(1), stackable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Next configured Etna port 25,26 as 10G uplink user port or stacking port. At boot up, it has the same value as current esmPortRunningMode. It takes some time to write to the EEPROM. Have at least more than 7 sec between each write operation" ::= { esmPortModeEntry 3 } -- The Ethernet Statistics Group -- -- The ethernet statistics group contains statistics -- measured by the probe for each monitored interface on -- this device. These statistics take the form of free -- running counters that start from zero when a valid entry -- is created. -- -- This group currently has statistics defined only for -- Ethernet interfaces. Each alcetherStatsEntry contains -- statistics for one Ethernet interface. The probe must -- create one alcetherStats entry for each monitored Ethernet -- interface on the device. alcetherStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcetherStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Ethernet statistics entries." ::= { physicalPort 2 } alcetherStatsEntry OBJECT-TYPE SYNTAX AlcetherStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of statistics kept for a particular Ethernet interface. As an example, an instance of the etherStatsPkts object might be named alcetherStatsPkts.1" INDEX { ifIndex } ::= { alcetherStatsTable 1 } AlcetherStatsEntry ::= SEQUENCE { alcetherClearStats INTEGER, alcetherLastClearStats TimeTicks, alcetherStatsCRCAlignErrors Counter64, alcetherStatsRxUndersizePkts Counter64, alcetherStatsTxUndersizePkts Counter64, alcetherStatsTxOversizePkts Counter64, alcetherStatsRxJabbers Counter64, alcetherStatsRxCollisions Counter64, alcetherStatsTxCollisions Counter64, alcetherStatsPkts64Octets Counter64, alcetherStatsPkts65to127Octets Counter64, alcetherStatsPkts128to255Octets Counter64, alcetherStatsPkts256to511Octets Counter64, alcetherStatsPkts512to1023Octets Counter64, alcetherStatsPkts1024to1518Octets Counter64, gigaEtherStatsPkts1519to4095Octets Counter64, gigaEtherStatsPkts4096to9215Octets Counter64, alcetherStatsPkts1519to2047Octets Counter64, alcetherStatsPkts2048to4095Octets Counter64, alcetherStatsPkts4096Octets Counter64, alcetherStatsRxGiantPkts Counter64, alcetherStatsRxDribbleNibblePkts Counter64, alcetherStatsRxLongEventPkts Counter64, alcetherStatsRxVlanTagPkts Counter64, alcetherStatsRxControlPkts Counter64, alcetherStatsRxLenChkErrPkts Counter64, alcetherStatsRxCodeErrPkts Counter64, alcetherStatsRxDvEventPkts Counter64, alcetherStatsRxPrevPktDropped Counter64, alcetherStatsTx64Octets Counter64, alcetherStatsTx65to127Octets Counter64, alcetherStatsTx128to255Octets Counter64, alcetherStatsTx256to511Octets Counter64, alcetherStatsTx512to1023Octets Counter64, alcetherStatsTx1024to1518Octets Counter64, alcetherStatsTx1519to2047Octets Counter64, alcetherStatsTx2048to4095Octets Counter64, alcetherStatsTx4096Octets Counter64, alcetherStatsTxRetryCount Counter64, alcetherStatsTxVlanTagPkts Counter64, alcetherStatsTxControlPkts Counter64, alcetherStatsTxLatePkts Counter64, alcetherStatsTxTotalBytesOnWire Counter64, alcetherStatsTxLenChkErrPkts Counter64, alcetherStatsTxExcDeferPkts Counter64 } alcetherClearStats OBJECT-TYPE SYNTAX INTEGER { default(0), reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to Clear all Statistics counters. By default, this object contains zero value." ::= { alcetherStatsEntry 1 } alcetherLastClearStats OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of SysUpTime at the time of all the statistics counters are cleared. By default, this object contains a zero value." ::= { alcetherStatsEntry 2 } alcetherStatsCRCAlignErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { alcetherStatsEntry 3 } alcetherStatsRxUndersizePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed." ::= { alcetherStatsEntry 4 } alcetherStatsTxUndersizePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed." ::= { alcetherStatsEntry 5 } alcetherStatsTxOversizePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted that were longer than 1518 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed." ::= { alcetherStatsEntry 6 } alcetherStatsRxJabbers OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that this definition of jabber is different than the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These documents define jabber as the condition where any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms." ::= { alcetherStatsEntry 7 } alcetherStatsRxCollisions OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment (in reception). Only for Ethernet Interfaces. The value returned will depend on the location of the RMON probe. Section 8.2.1.3 (10BASE-5) and section 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision, in the receive mode, if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment would. Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coax segments to which the repeater is connected." ::= { alcetherStatsEntry 8 } alcetherStatsTxCollisions OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment (in transmition). Only for Ethernet Interfaces. The value returned will depend on the location of the RMON probe. Section 8.2.1.3 (10BASE-5) and section 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision, in the receive mode, if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment would. Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coax segments to which the repeater is connected." ::= { alcetherStatsEntry 9 } alcetherStatsPkts64Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets)." ::= { alcetherStatsEntry 10 } alcetherStatsPkts65to127Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { alcetherStatsEntry 11 } alcetherStatsPkts128to255Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { alcetherStatsEntry 12 } alcetherStatsPkts256to511Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { alcetherStatsEntry 13 } alcetherStatsPkts512to1023Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { alcetherStatsEntry 14 } alcetherStatsPkts1024to1518Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). For both Ethernet and GigaEthernet." ::= { alcetherStatsEntry 15 } gigaEtherStatsPkts1519to4095Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 1519 and 4095 octets in length inclusive (excluding framing bits but including FCS octets). Only for GigaEthernet interfaces" ::= { alcetherStatsEntry 16 } gigaEtherStatsPkts4096to9215Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) received that were between 4096 and 9215 octets in length inclusive (excluding framing bits but including FCS octets). Only for GigaEthernet interfaces" ::= { alcetherStatsEntry 17 } alcetherStatsPkts1519to2047Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames(including error packets) received that were between 1519 and 2047 bytes in length inclusive (excluding framing bits but including FCS bytes). " ::= { alcetherStatsEntry 18 } alcetherStatsPkts2048to4095Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames(including error packets) received that were between 2048 and 4095 bytes in length inclusive (excluding framing bits but including FCS bytes). " ::= { alcetherStatsEntry 19 } alcetherStatsPkts4096Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames(including error packets) received that were greater than or equal to 4096 bytes in length inclusive (excluding framing bits but including FCS bytes). " ::= { alcetherStatsEntry 20 } alcetherStatsRxGiantPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that are greater than the specified Max length value, with a valid CRC, dropped because too long. " ::= { alcetherStatsEntry 21 } alcetherStatsRxDribbleNibblePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which a dribble nibble has been received and CRC is correct. " ::= { alcetherStatsEntry 22 } alcetherStatsRxLongEventPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which the Carrier sense exceeds 50000 bit times for 10 Mbits/sec or 80000 bit times for 100 Mbits/sec." ::= { alcetherStatsEntry 23 } alcetherStatsRxVlanTagPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which Type/Length field contains the VLAN protocol identifier (0x8100). " ::= { alcetherStatsEntry 24 } alcetherStatsRxControlPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that were recognized as control frames." ::= { alcetherStatsEntry 25 } alcetherStatsRxLenChkErrPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which the frame length field value in the Type/Length field does not match the actual data bytes length and is NOT a type field." ::= { alcetherStatsEntry 26 } alcetherStatsRxCodeErrPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which one or more nibbles were signaled as errors during reception of the frame." ::= { alcetherStatsEntry 27 } alcetherStatsRxDvEventPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which a RX_DV event (packet not too long enough to be valid packet) has been seen before the correct frame." ::= { alcetherStatsEntry 28 } alcetherStatsRxPrevPktDropped OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames for which a packet has been dropped (because of too small IFG) before the correct frame." ::= { alcetherStatsEntry 29 } alcetherStatsTx64Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames of 64 bytes." ::= { alcetherStatsEntry 30 } alcetherStatsTx65to127Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 65 and 127 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 31 } alcetherStatsTx128to255Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 128 and 255 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 32 } alcetherStatsTx256to511Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 256 and 511 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 33 } alcetherStatsTx512to1023Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 512 and 1023 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 34 } alcetherStatsTx1024to1518Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 1024 and 1518 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 35 } alcetherStatsTx1519to2047Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 1519 and 2047 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 36 } alcetherStatsTx2048to4095Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were between 2048 and 4095 bytes in length inclusive (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 37 } alcetherStatsTx4096Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were greater than or equal to 4096 bytes in length and less than Max frame length (excluding framing bits but including FCS bytes)." ::= { alcetherStatsEntry 38 } alcetherStatsTxRetryCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of collisions that the frames faced during transmission attempts." ::= { alcetherStatsEntry 39 } alcetherStatsTxVlanTagPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames for which Type/Length field contains the VLAN protocol identifier (0x8100)." ::= { alcetherStatsEntry 40 } alcetherStatsTxControlPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames that were recognised as control frames." ::= { alcetherStatsEntry 41 } alcetherStatsTxLatePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of late collisions that occured beyond the collision window." ::= { alcetherStatsEntry 42 } alcetherStatsTxTotalBytesOnWire OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes transmitted on wire, including all bytes from collided attempts." ::= { alcetherStatsEntry 43 } alcetherStatsTxLenChkErrPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted frames for which the frame length field value in the Type/Length field does not match the actual data bytes length and is NOT a Type field." ::= { alcetherStatsEntry 44 } alcetherStatsTxExcDeferPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that were deferred in excess of 6071 nibble-times in 100 Mbps, 24287 bit-times in 10 Mbps mode. These frames are dropped.(This stat is only in case of Half duplex and excessive defer bit reset)." ::= { alcetherStatsEntry 45 } -- 10 GIG specifics parameters alcether10GigTable OBJECT-TYPE SYNTAX SEQUENCE OF Alcether10GigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 10 Gig specifics entries." ::= { physicalPort 4 } alcether10GigEntry OBJECT-TYPE SYNTAX Alcether10GigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will be populated with the 10 gig only entries. The management interface can use it to specify if A or B is the primary." INDEX { ifIndex } ::= { alcether10GigTable 1 } Alcether10GigEntry ::= SEQUENCE { alcether10GigPrimary INTEGER } alcether10GigPrimary OBJECT-TYPE SYNTAX INTEGER { phyAprimary(1), phyBprimary(2), notApplicable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the object to 1 will make phy A as primary, 2- phy B as pirmary. Value 3 should not be set. " ::= { alcether10GigEntry 1 } -- End of 10 GIG specifics parameters -- Ethernet Driver Tables ***************************** -- EsmHybridConf table contains the configuration -- information about the configured inactive media for the -- hybrid port only. -- Implementation of this group is mandantory. -- -- Note that entries in this MIB Table can NOT be created by the user, only modified esmHybridConfTable OBJECT-TYPE SYNTAX SEQUENCE OF EsmHybridConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of inactive hybrid port instances." ::= { physicalPort 3 } esmHybridConfEntry OBJECT-TYPE SYNTAX EsmHybridConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ESM Physical Port entry." INDEX { ifIndex } ::= { esmHybridConfTable 1 } EsmHybridConfEntry ::= SEQUENCE { esmHybridPortCfgSpeed INTEGER, esmHybridPortCfgDuplexMode INTEGER, esmHybridPortCfgAutoNegotiation INTEGER, esmHybridPortCfgCrossover INTEGER, esmHybridPortCfgFlow INTEGER, esmHybridPortCfgInactiveType INTEGER, esmHybridPortCfgSFPType DisplayString } esmHybridPortCfgSpeed OBJECT-TYPE SYNTAX INTEGER { speed100(1), speed10(2), speedAuto(3), speed1000(5), speed10000(6), speedMax100(8), speedMax1000(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configured port line speed of this ESM port." ::= { esmHybridConfEntry 1 } esmHybridPortCfgDuplexMode OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configured port duplex mode of this ESM port. Note: GigaEthernet support only full-duplex." ::= { esmHybridConfEntry 2 } esmHybridPortCfgAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to enable or disable the port auto negotiation." DEFVAL { disable } ::= { esmHybridConfEntry 3 } esmHybridPortCfgCrossover OBJECT-TYPE SYNTAX INTEGER { mdi(1), mdix(2), auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allow the user to configure port crossover." DEFVAL { auto } ::= { esmHybridConfEntry 4 } esmHybridPortCfgFlow OBJECT-TYPE SYNTAX INTEGER { disable(1), enabledXmit(2), enabledRcv(3), enabledXmitAndRcv(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used for flow control of hybrid ports. It is similar to the dot3PauseAdminMode object in dot3PauseTable. It is used to configure pause for fiber media." DEFVAL { disable } ::= { esmHybridConfEntry 5 } esmHybridPortCfgInactiveType OBJECT-TYPE SYNTAX INTEGER { fiber(1), copper(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to hybrid ports . It indicates the configured inactive media type." ::= { esmHybridConfEntry 6 } esmHybridPortCfgSFPType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to fiber ports. The string indicates the type of SFP/GBIC of active media." ::= { esmHybridConfEntry 7 } -- End-to-End Flow Vlan Configuration ***************** esmE2EFlowVlan OBJECT-TYPE SYNTAX INTEGER (0 .. 4094) MAX-ACCESS read-write STATUS current DESCRIPTION "0 - Deleting End-to-End flow control 1-4094 - Enable End-to-End flow control and use the Vlan configured as for End-to-End flow" ::= { alcatelIND1PortMIBObjects 3 } -- Digital Diagnostics Monitoring (DDM) ************************** ddmConfig OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables DDM software feature in the system." DEFVAL { disable } ::= { ddmConfiguration 1 } ddmTrapConfig OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects enables/disables traps for DDM warning/alarm threshold violations." DEFVAL { disable } ::= { ddmConfiguration 2 } ddmNotificationType OBJECT-TYPE SYNTAX INTEGER { clearViolation(1), highAlarm(2), highWarning(3), lowWarning(4), lowAlarm(5) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object defines the trap type for monitored DDM parameters." ::= { ddmConfiguration 3 } -- esmViolationRecoveryTime Configuration ***************** esmViolationRecoveryTrap OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects enables/disables traps for user-port shutdown" DEFVAL { disable } ::= { esmViolationRecovery 1 } esmViolationRecoveryTime OBJECT-TYPE SYNTAX INTEGER (0 .. 600) MAX-ACCESS read-write STATUS current DESCRIPTION "0 - Disable the timer 30 - 600 - timeout value to re-enable the UserPort ports" ::= { esmViolationRecovery 2 } esmViolationRecoveryNotificationType OBJECT-TYPE SYNTAX INTEGER { clearViolation(1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object defines the trap type for monitored violation-recovery parameters." ::= { esmViolationRecovery 3 } ddmInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF DdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ddmInfoTable has an entry for each SFP/XFP in the system that supports Digital Diagnostic Monitoring (DDM). The table is indexed by ifIndex. Each row in this table is dynamically added and removed internally by the system based on the presence or absence of DDM capable SFP/XFP components." ::= { physicalPort 5 } ddmInfoEntry OBJECT-TYPE SYNTAX DdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row represents a particular SFP/XFP that supports Digital Diagnostic Monitoring. Entries are created and deleted internally by the system." INDEX { ifIndex } ::= { ddmInfoTable 1} DdmEntry ::= SEQUENCE { ddmTemperature Integer32, ddmTempLowWarning Integer32, ddmTempLowAlarm Integer32, ddmTempHiWarning Integer32, ddmTempHiAlarm Integer32, ddmSupplyVoltage Integer32, ddmSupplyVoltageLowWarning Integer32, ddmSupplyVoltageLowAlarm Integer32, ddmSupplyVoltageHiWarning Integer32, ddmSupplyVoltageHiAlarm Integer32, ddmTxBiasCurrent Integer32, ddmTxBiasCurrentLowWarning Integer32, ddmTxBiasCurrentLowAlarm Integer32, ddmTxBiasCurrentHiWarning Integer32, ddmTxBiasCurrentHiAlarm Integer32, ddmTxOutputPower Integer32, ddmTxOutputPowerLowWarning Integer32, ddmTxOutputPowerLowAlarm Integer32, ddmTxOutputPowerHiWarning Integer32, ddmTxOutputPowerHiAlarm Integer32, ddmRxOpticalPower Integer32, ddmRxOpticalPowerLowWarning Integer32, ddmRxOpticalPowerLowAlarm Integer32, ddmRxOpticalPowerHiWarning Integer32, ddmRxOpticalPowerHiAlarm Integer32 } ddmTemperature OBJECT-TYPE SYNTAX Integer32 (-200000 | -150000..150000) UNITS "thousandth of a degree celcius" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTemperature indicates the current temperature of the SFP/XFP in 1000s of degrees Celsius. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 1 } ddmTempLowWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -150000..150000) UNITS "thousandth of a degree celcius" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTempLowWarning indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a low-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 2 } ddmTempLowAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -150000..150000) UNITS "thousandth of a degree celcius" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTempLowAlarm indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a low-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 3 } ddmTempHiWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -150000..150000) UNITS "thousandth of a degree celcius" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTempHiWarning indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 4 } ddmTempHiAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -150000..150000) UNITS "thousandth of a degree celcius" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTempHiAlarm indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 5 } ddmSupplyVoltage OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a volt" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmSupplyVoltage indicates the current supply voltage of the SFP/XFP in 1000s of Volts (V). A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 6 } ddmSupplyVoltageLowWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a volt" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmSupplyVoltageLowWarning indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 7 } ddmSupplyVoltageLowAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a volt" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmSupplyVoltageLowAlarm indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 8 } ddmSupplyVoltageHiWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a volt" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmSupplyVoltageHiWarning indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 9 } ddmSupplyVoltageHiAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a volt" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmSupplyVoltageHiAlarm indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 10 } ddmTxBiasCurrent OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a milli-Ampere" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxBiasCurrent indicates the current Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA). A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 11 } ddmTxBiasCurrentLowWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a milli-Ampere" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxBiasCurrentLowWarning indicates the Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a low-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 12 } ddmTxBiasCurrentLowAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a milli-Ampere" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxBiasCurrentLowAlarm indicates the Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a low-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 13 } ddmTxBiasCurrentHiWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a milli-Ampere" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxBiasCurrentHiWarning indicates the Transmit Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a hi-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 14 } ddmTxBiasCurrentHiAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | 0..10000) UNITS "thousandth of a milli-Ampere" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxBiasCurrentHiAlarm indicates the Transmit Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 15 } ddmTxOutputPower OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 16 } ddmTxOutputPowerLowWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxOutputPowerLowWarning indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a low-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 17 } ddmTxOutputPowerLowAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxOutputPowerLowAlarm indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a low-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 18 } ddmTxOutputPowerHiWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxOutputPowerHiWarning indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 19 } ddmTxOutputPowerHiAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmTxOutputPowerHiAlarm indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 20 } ddmRxOpticalPower OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmRxOpticalPower indicates the current Received Optical Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 21 } ddmRxOpticalPowerLowWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmRxOpticalPowerLowWarning indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a low-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 22 } ddmRxOpticalPowerLowAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmRxOpticalPowerLowAlarm indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a low-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 23 } ddmRxOpticalPowerHiWarning OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmRxOpticalPowerHiWarning indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a hi-warning. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 24 } ddmRxOpticalPowerHiAlarm OBJECT-TYPE SYNTAX Integer32 (-200000 | -40000..10000) UNITS "thousandth of a dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ddmRxOpticalPowerHiAlarm indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable." ::= { ddmInfoEntry 25 } -- Ethernet Driver Trap ********************* esmDrvTrapDropsLink NOTIFICATION-TYPE OBJECTS { esmPortSlot, esmPortIF, ifInErrors, ifOutErrors, esmDrvTrapDrops } STATUS current DESCRIPTION "When the Ethernet code drops the link because of excessive errors, a Trap is sent." ::= { cmmEsmDrvTraps 0 1 } e2eStackTopoChangeTrap NOTIFICATION-TYPE OBJECTS { esmE2EFlowVlan } STATUS current DESCRIPTION "Trap Generated when Stack Topology changes." ::= { cmmEsmDrvTraps 0 2 } ddmTemperatureThresholdViolated NOTIFICATION-TYPE OBJECTS { ifIndex, ddmNotificationType, ddmTemperature } STATUS current DESCRIPTION "This object notifies management station if an SFP/XFP/SFP+ temperature has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ temperature." ::= { ddmNotifications 0 1 } ddmVoltageThresholdViolated NOTIFICATION-TYPE OBJECTS { ifIndex, ddmNotificationType, ddmSupplyVoltage } STATUS current DESCRIPTION "This object notifies management station if an SFP/XFP/SFP+ supply voltage has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ supply voltage." ::= { ddmNotifications 0 2 } ddmCurrentThresholdViolated NOTIFICATION-TYPE OBJECTS { ifIndex, ddmNotificationType, ddmTxBiasCurrent } STATUS current DESCRIPTION "This object notifies management station if an SFP/XFP/SFP+ Tx bias current has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Tx bias current." ::= { ddmNotifications 0 3 } ddmTxPowerThresholdViolated NOTIFICATION-TYPE OBJECTS { ifIndex, ddmNotificationType, ddmTxOutputPower } STATUS current DESCRIPTION "This object notifies management station if an SFP/XFP/SFP+ Tx output power has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Tx output power." ::= { ddmNotifications 0 4 } ddmRxPowerThresholdViolated NOTIFICATION-TYPE OBJECTS { ifIndex, ddmNotificationType, ddmRxOpticalPower } STATUS current DESCRIPTION "This object notifies management station if an SFP/XFP/SFP+ Rx optical power has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Rx optical power." ::= { ddmNotifications 0 5 } esmViolationRecoveryTimeout NOTIFICATION-TYPE OBJECTS { ifIndex, esmViolationRecoveryNotificationType } STATUS current DESCRIPTION "This object notifies management station if User-Port ports get re-enabled after esm violation recovery time" ::= { esmViolationNotifications 0 1 } -- conformance information alcatelIND1PortMIBCompliances OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 1 } alcatelIND1PortMIBGroups OBJECT IDENTIFIER ::= { alcatelIND1PortMIBConformance 2 } -- compliance statements esmConfPortCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the configuration of Ethernet ports." MODULE -- this module MANDATORY-GROUPS { esmConfMIBGroup, esmDetectedConfMIBGroup, esmPortModeMIBGroup, ddmInfoGroup, ddmConfigGroup, ddmNotificationsGroup, violationRecoveryGroup, violationNotificationsGroup } ::= { alcatelIND1PortMIBCompliances 1 } alcEtherStatsCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the Statistics of the Ethernet ports." MODULE -- this module MANDATORY-GROUPS { alcEtherStatsMIBGroup } ::= { alcatelIND1PortMIBCompliances 2 } -- units of conformance esmConfMIBGroup OBJECT-GROUP OBJECTS { esmPortCfgSpeed, esmPortCfgDuplexMode, esmPortCfgIFG, esmPortPauseSlotTime, esmPortMaxFloodRate, esmPortFloodMcastEnable, esmPortCfgMaxFrameSize, esmPortCfgAutoNegotiation, esmPortCfgCrossover, esmPortCfgFlow, esmPortFloodUnknownUcastEnable, esmPortMaxUnknownUcastFloodRate,esmPortMaxMcastFloodRate,esmPortFloodBcastEnable, esmPortMaxFloodRateLimit,esmPortMaxUnknownUcastFloodRateLimit,esmPortMaxMcastFloodRateLimit, esmPortCfgSFPType } STATUS current DESCRIPTION "A collection of objects to support the management of global configuration parameters of the Ethernet ports." ::= { alcatelIND1PortMIBGroups 1 } esmDetectedConfMIBGroup OBJECT-GROUP OBJECTS { esmPortAutoSpeed, esmPortAutoDuplexMode } STATUS current DESCRIPTION "A collection of objects to support the Detected configuration parameters of the Ethernet ports." ::= { alcatelIND1PortMIBGroups 2 } alcEtherStatsMIBGroup OBJECT-GROUP OBJECTS { alcetherClearStats, alcetherLastClearStats, alcetherStatsCRCAlignErrors, alcetherStatsRxUndersizePkts, alcetherStatsTxUndersizePkts, alcetherStatsTxOversizePkts, alcetherStatsRxJabbers, alcetherStatsRxCollisions, alcetherStatsTxCollisions, alcetherStatsPkts64Octets, alcetherStatsPkts65to127Octets, alcetherStatsPkts128to255Octets, alcetherStatsPkts256to511Octets, alcetherStatsPkts512to1023Octets, alcetherStatsPkts1024to1518Octets, gigaEtherStatsPkts1519to4095Octets, gigaEtherStatsPkts4096to9215Octets, alcetherStatsPkts1519to2047Octets, alcetherStatsPkts2048to4095Octets, alcetherStatsPkts4096Octets, alcetherStatsRxGiantPkts, alcetherStatsRxDribbleNibblePkts, alcetherStatsRxLongEventPkts, alcetherStatsRxVlanTagPkts, alcetherStatsRxControlPkts, alcetherStatsRxLenChkErrPkts, alcetherStatsRxCodeErrPkts, alcetherStatsRxDvEventPkts, alcetherStatsRxPrevPktDropped, alcetherStatsTx64Octets, alcetherStatsTx65to127Octets, alcetherStatsTx128to255Octets, alcetherStatsTx256to511Octets, alcetherStatsTx512to1023Octets, alcetherStatsTx1024to1518Octets, alcetherStatsTx1519to2047Octets, alcetherStatsTx2048to4095Octets, alcetherStatsTx4096Octets, alcetherStatsTxRetryCount, alcetherStatsTxVlanTagPkts, alcetherStatsTxControlPkts, alcetherStatsTxLatePkts, alcetherStatsTxTotalBytesOnWire, alcetherStatsTxLenChkErrPkts, alcetherStatsTxExcDeferPkts } STATUS current DESCRIPTION "A collection of objects to provide all the statistics related to the Ethernet and GigaEthernert ports." ::= { alcatelIND1PortMIBGroups 3 } alcPortNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { esmDrvTrapDropsLink } STATUS current DESCRIPTION "The Port MIB Notification Group." ::= { alcatelIND1PortMIBGroups 4 } esmPortModeMIBGroup OBJECT-GROUP OBJECTS { esmPortRunningMode, esmPortSavedMode } STATUS current DESCRIPTION "A collection of objects to support the management of global configuration parameters of the stacking ports." ::= { alcatelIND1PortMIBGroups 5 } ddmInfoGroup OBJECT-GROUP OBJECTS { ddmTemperature, ddmTempLowWarning, ddmTempLowAlarm, ddmTempHiWarning, ddmTempHiAlarm, ddmSupplyVoltage, ddmSupplyVoltageLowWarning, ddmSupplyVoltageLowAlarm, ddmSupplyVoltageHiWarning, ddmSupplyVoltageHiAlarm, ddmTxBiasCurrent, ddmTxBiasCurrentLowWarning, ddmTxBiasCurrentLowAlarm, ddmTxBiasCurrentHiWarning, ddmTxBiasCurrentHiAlarm, ddmTxOutputPower, ddmTxOutputPowerLowWarning, ddmTxOutputPowerLowAlarm, ddmTxOutputPowerHiWarning, ddmTxOutputPowerHiAlarm, ddmRxOpticalPower, ddmRxOpticalPowerLowWarning, ddmRxOpticalPowerLowAlarm, ddmRxOpticalPowerHiWarning, ddmRxOpticalPowerHiAlarm } STATUS current DESCRIPTION "A collection of objects to provide digital diagnostics information related to SFPs, XFPs, and SFP+s." ::= { alcatelIND1PortMIBGroups 6 } ddmConfigGroup OBJECT-GROUP OBJECTS { ddmConfig, ddmTrapConfig } STATUS current DESCRIPTION "A collection of objects to allow configuration of DDM and DDM traps." ::= { alcatelIND1PortMIBGroups 7 } ddmNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { ddmTemperatureThresholdViolated, ddmVoltageThresholdViolated, ddmCurrentThresholdViolated, ddmTxPowerThresholdViolated, ddmRxPowerThresholdViolated } STATUS current DESCRIPTION "A collection of notifications used to indicate DDM threshold violations." ::= { alcatelIND1PortMIBGroups 8 } violationRecoveryGroup OBJECT-GROUP OBJECTS { esmViolationRecoveryTrap, esmViolationRecoveryTime } STATUS current DESCRIPTION "A collection of objects to allow configuration of violationRecovery." ::= { alcatelIND1PortMIBGroups 9 } violationNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { esmViolationRecoveryTimeout } STATUS current DESCRIPTION "A collection of notifications used to indicate esm violation recovery timeout." ::= { alcatelIND1PortMIBGroups 10 } END