-- ===================================================================== -- == OG-STATUSv2-MIB: == -- == Opengear status Management Information Base == -- == == -- == (c) Copyright 2013-2020 Opengear Inc. == -- ===================================================================== OG-STATUSv2-MIB DEFINITIONS ::= BEGIN IMPORTS opengear FROM OG-SMI-MIB MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI Integer32, Unsigned32, Counter32, Counter64 FROM SNMPv2-SMI MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF DateAndTime, DisplayString FROM SNMPv2-TC; ogStatus2 MODULE-IDENTITY LAST-UPDATED "202011100000Z" ORGANIZATION "Opengear Inc." CONTACT-INFO "Opengear Inc. 630 West 9560 South, Suite A, Sandy, UT 84070 support@opengear.com" DESCRIPTION "Extended network interface status for failover" REVISION "202011100000Z" DESCRIPTION "Opengear extended status and alert MIB" REVISION "201702030000Z" DESCRIPTION "Add CLI session alert." REVISION "201608260000Z" DESCRIPTION "Correct Power Supply table and values." REVISION "201401280000Z" DESCRIPTION "Initial revision" ::= { opengear 17 } ogSystem OBJECT IDENTIFIER ::= { ogStatus2 1 } ogFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current device firmware." ::= { ogSystem 1 } ogSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current serial number (if applicable)." ::= { ogSystem 2 } ogSerialPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The devices serial port status table." ::= { ogStatus2 2 } ogSerialPortEntry OBJECT-TYPE SYNTAX SerialPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A serial port status entry." INDEX { ogSerialPortIndex } ::= { ogSerialPortTable 1 } SerialPortEntry ::= SEQUENCE { ogSerialPortIndex Integer32, ogSerialPortLabel DisplayString, ogSerialPortSpeed Integer32, ogSerialPortDataBits Integer32, ogSerialPortParity INTEGER, ogSerialPortStopBits INTEGER, ogSerialPortFlowControl INTEGER, ogSerialPortMode INTEGER, ogSerialPortLogLevel INTEGER, ogSerialPortRxBytes Counter64, ogSerialPortTxBytes Counter64, ogSerialPortFramingErrors Counter64, ogSerialPortParityErrors Counter64, ogSerialPortOverrunErrors Counter64, ogSerialPortBreaks Counter64, ogSerialPortDCD INTEGER, ogSerialPortDTR INTEGER, ogSerialPortDSR INTEGER, ogSerialPortCTS INTEGER, ogSerialPortRTS INTEGER } ogSerialPortIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the serial port table of this status" ::= { ogSerialPortEntry 1 } ogSerialPortLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port descriptive name" ::= { ogSerialPortEntry 2 } ogSerialPortSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port speed in bits per second" ::= { ogSerialPortEntry 3 } ogSerialPortDataBits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port character size" ::= { ogSerialPortEntry 4 } ogSerialPortParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3), mark(4), space(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port parity" ::= { ogSerialPortEntry 5 } ogSerialPortStopBits OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), oneAndAHalf(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port number of stop bits" ::= { ogSerialPortEntry 6 } ogSerialPortFlowControl OBJECT-TYPE SYNTAX INTEGER { none(1), hardware(2), software(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port flow control type" ::= { ogSerialPortEntry 7 } ogSerialPortMode OBJECT-TYPE SYNTAX INTEGER { none(1), console(2), sdt(3), terminal(4), bridge(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port operational mode type" ::= { ogSerialPortEntry 8 } ogSerialPortLogLevel OBJECT-TYPE SYNTAX INTEGER { disabled(1), connect(2), inputAndOutput(3), inputOnly(4), outputOnly(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port logging level" ::= { ogSerialPortEntry 9 } ogSerialPortRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port bytes received" ::= { ogSerialPortEntry 10 } ogSerialPortTxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port bytes transmitted" ::= { ogSerialPortEntry 11 } ogSerialPortFramingErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port framing error total." ::= { ogSerialPortEntry 12 } ogSerialPortParityErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port parity error total." ::= { ogSerialPortEntry 13 } ogSerialPortOverrunErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port Overrun Error total." ::= { ogSerialPortEntry 14 } ogSerialPortBreaks OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port break total" ::= { ogSerialPortEntry 15 } ogSerialPortDCD OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DCD signal." ::= { ogSerialPortEntry 16 } ogSerialPortDTR OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DTR signal." ::= { ogSerialPortEntry 17 } ogSerialPortDSR OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the DSR signal." ::= { ogSerialPortEntry 18 } ogSerialPortCTS OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the CTS signal." ::= { ogSerialPortEntry 19 } ogSerialPortRTS OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the RTS signal." ::= { ogSerialPortEntry 20 } ogSerialUserTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entity's serial port users table." ::= { ogStatus2 3 } ogSerialUserEntry OBJECT-TYPE SYNTAX SerialUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user logged in on the serial port" INDEX { ogSerialUserIndex } ::= { ogSerialUserTable 1 } SerialUserEntry ::= SEQUENCE { ogSerialUserIndex Integer32, ogSerialUserStartTime DateAndTime, ogSerialUserPort Integer32, ogSerialUserLabel DisplayString, ogSerialUserName DisplayString } ogSerialUserIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the serial port active users table" ::= { ogSerialUserEntry 1 } ogSerialUserStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time and date the user session started." ::= { ogSerialUserEntry 2 } ogSerialUserPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial port number" ::= { ogSerialUserEntry 3 } ogSerialUserLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The readable label for the serial port." ::= { ogSerialUserEntry 4 } ogSerialUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the user logged in on the port." ::= { ogSerialUserEntry 5 } ogHostTable OBJECT-TYPE SYNTAX SEQUENCE OF HostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of monitored network hosts." ::= { ogStatus2 4 } ogHostEntry OBJECT-TYPE SYNTAX HostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A monitored network host." INDEX { ogHostIndex } ::= { ogHostTable 1 } HostEntry ::= SEQUENCE { ogHostIndex Integer32, ogHostName DisplayString, ogHostIpV4Address DisplayString, ogHostIpV6Address DisplayString } ogHostIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the network host active users table" ::= { ogHostEntry 1 } ogHostName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of this monitored network host." ::= { ogHostEntry 2 } ogHostIpV4Address OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv4 Address of this monitored network host." ::= { ogHostEntry 3 } ogHostIpV6Address OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv6 Address of this monitored network host." ::= { ogHostEntry 4 } ogHostServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF HostServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of services belonging to a monitored host." ::= { ogStatus2 5 } ogHostServiceEntry OBJECT-TYPE SYNTAX HostServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A monitored host service." INDEX { ogHostIndex, ogHostServiceIndex } ::= { ogHostServiceTable 1 } HostServiceEntry ::= SEQUENCE { ogHostServiceIndex Integer32, ogHostServiceHost OBJECT IDENTIFIER, ogHostServiceType INTEGER, ogHostServicePort Unsigned32, ogHostServiceStatus INTEGER, ogHostServiceCounter Counter32 } ogHostServiceIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the RPC outlet table" ::= { ogHostServiceEntry 1 } ogHostServiceHost OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The monitored host this service belongs to" ::= { ogHostServiceEntry 2 } ogHostServiceType OBJECT-TYPE SYNTAX INTEGER { tcp(1), udp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of service this is." ::= { ogHostServiceEntry 3 } ogHostServicePort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The TCP Port this service is on." ::= { ogHostServiceEntry 4 } ogHostServiceStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), available(2), unavailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The availabalilty of this service." ::= { ogHostServiceEntry 5 } ogHostServiceCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of alerts related to this service." ::= { ogHostServiceEntry 6 } ogHostUserTable OBJECT-TYPE SYNTAX SEQUENCE OF HostUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entity's serial port users table." ::= { ogStatus2 6 } ogHostUserEntry OBJECT-TYPE SYNTAX HostUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user logged in on the serial port" INDEX { ogHostUserIndex } ::= { ogHostUserTable 1 } HostUserEntry ::= SEQUENCE { ogHostUserIndex Integer32, ogHostUserHost OBJECT IDENTIFIER, ogHostUserStartTime DateAndTime, ogHostUserAddress DisplayString, ogHostUserHostName DisplayString, ogHostUserName DisplayString } ogHostUserIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the network host active users table" ::= { ogHostUserEntry 1 } ogHostUserHost OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The monitored host this user is associated with." ::= { ogHostUserEntry 2 } ogHostUserStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time the user session started." ::= { ogHostUserEntry 3 } ogHostUserAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The network host address." ::= { ogHostUserEntry 4 } ogHostUserHostName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The network host's host name." ::= { ogHostUserEntry 5 } ogHostUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The network host's active username." ::= { ogHostUserEntry 6 } ogWebUserTable OBJECT-TYPE SYNTAX SEQUENCE OF WebUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entity's Web Interface users table." ::= { ogStatus2 7 } ogWebUserEntry OBJECT-TYPE SYNTAX WebUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user logged in to the Web Interface" INDEX { ogWebUserIndex } ::= { ogWebUserTable 1 } WebUserEntry ::= SEQUENCE { ogWebUserIndex Integer32, ogWebUserStartTime DateAndTime, ogWebUserName DisplayString, ogWebUserSourceAddress DisplayString, ogWebUserSourcePort Integer32 } ogWebUserIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the Web Interface users table" ::= { ogWebUserEntry 1 } ogWebUserStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The web users session start date and time." ::= { ogWebUserEntry 2 } ogWebUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users active username." ::= { ogWebUserEntry 3 } ogWebUserSourceAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users source address." ::= { ogWebUserEntry 4 } ogWebUserSourcePort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The web users source tcp port." ::= { ogWebUserEntry 5 } ogEmdTable OBJECT-TYPE SYNTAX SEQUENCE OF EmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This devices temperature monitoring table." ::= { ogStatus2 8 } ogEmdEntry OBJECT-TYPE SYNTAX EmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "EMD status entry" INDEX { ogEmdIndex } ::= { ogEmdTable 1 } EmdEntry ::= SEQUENCE { ogEmdIndex Integer32, ogEmdName DisplayString, ogEmdDescription DisplayString, ogEmdEnabled INTEGER, ogEmdLogEnabled INTEGER, ogEmdConnectType INTEGER, ogEmdTemperatureTotal Counter32, ogEmdHumidityTotal Counter32, ogEmdDioInputTotal Counter32 } ogEmdIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the EMD status table" ::= { ogEmdEntry 1 } ogEmdName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the EMD device." ::= { ogEmdEntry 2 } ogEmdDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the EMD device." ::= { ogEmdEntry 3 } ogEmdEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The enabled status of the EMD" ::= { ogEmdEntry 4 } ogEmdLogEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The logging status of the EMD" ::= { ogEmdEntry 5 } ogEmdConnectType OBJECT-TYPE SYNTAX INTEGER { internal(1), serial(2), network(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "How the EMD device is connected." ::= { ogEmdEntry 6 } ogEmdTemperatureTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of temperature sensors contained in this EMD." ::= { ogEmdEntry 7 } ogEmdHumidityTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of humidity sensors contained in this EMD." ::= { ogEmdEntry 8 } ogEmdDioInputTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DIOs contained in this EMD." ::= { ogEmdEntry 9 } ogEmdTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF EmdTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of temperature sensors belonging to EMDs" ::= { ogStatus2 9 } ogEmdTemperatureEntry OBJECT-TYPE SYNTAX EmdTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "EMD status entry" INDEX { ogEmdIndex, ogEmdTemperatureIndex } ::= { ogEmdTemperatureTable 1 } EmdTemperatureEntry ::= SEQUENCE { ogEmdTemperatureIndex Integer32, ogEmdTemperatureEmd OBJECT IDENTIFIER, ogEmdTemperatureName DisplayString, ogEmdTemperatureDescription DisplayString, ogEmdTemperatureValue Integer32, ogEmdTemperatureCounter Counter32 } ogEmdTemperatureIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the EMD status table" ::= { ogEmdTemperatureEntry 1 } ogEmdTemperatureEmd OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The EMD this temperature sensor is related to." ::= { ogEmdTemperatureEntry 2 } ogEmdTemperatureName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the EMD temperature sensor." ::= { ogEmdTemperatureEntry 3 } ogEmdTemperatureDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the EMD device." ::= { ogEmdTemperatureEntry 4 } ogEmdTemperatureValue OBJECT-TYPE SYNTAX Integer32 UNITS "degrees" MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature reading on the EMD." ::= { ogEmdTemperatureEntry 5 } ogEmdTemperatureCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alerts triggered on the EMD." ::= { ogEmdTemperatureEntry 6 } ogEmdHumidityTable OBJECT-TYPE SYNTAX SEQUENCE OF EmdHumidityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of humidity sensors belonging to EMDs." ::= { ogStatus2 10 } ogEmdHumidityEntry OBJECT-TYPE SYNTAX EmdHumidityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "EMD Humidity sensor status entry." INDEX { ogEmdIndex, ogEmdHumidityIndex } ::= { ogEmdHumidityTable 1 } EmdHumidityEntry ::= SEQUENCE { ogEmdHumidityIndex Integer32, ogEmdHumidityEmd OBJECT IDENTIFIER, ogEmdHumidityName DisplayString, ogEmdHumidityDescription DisplayString, ogEmdHumidityValue Integer32, ogEmdHumidityCounter Counter32 } ogEmdHumidityIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the EMD status table" ::= { ogEmdHumidityEntry 1 } ogEmdHumidityEmd OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The EMD this humidity sensor is related to." ::= { ogEmdHumidityEntry 2 } ogEmdHumidityName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the EMD." ::= { ogEmdHumidityEntry 3 } ogEmdHumidityDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the EMD device." ::= { ogEmdHumidityEntry 4 } ogEmdHumidityValue OBJECT-TYPE SYNTAX Integer32 UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The current humidity value on the EMD" ::= { ogEmdHumidityEntry 5 } ogEmdHumidityCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alerts triggered on the EMD" ::= { ogEmdHumidityEntry 6 } ogEmdDioTable OBJECT-TYPE SYNTAX SEQUENCE OF EmdDioEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths Digital I/O status table." ::= { ogStatus2 11 } ogEmdDioEntry OBJECT-TYPE SYNTAX EmdDioEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Digital I/O status entry" INDEX { ogEmdIndex, ogEmdDioIndex } ::= { ogEmdDioTable 1 } EmdDioEntry ::= SEQUENCE { ogEmdDioIndex Integer32, ogEmdDioEmd OBJECT IDENTIFIER, ogEmdDioName DisplayString, ogEmdDioDescription DisplayString, ogEmdDioType INTEGER, ogEmdDioDirection INTEGER, ogEmdDioState INTEGER, ogEmdDioTriggerMode INTEGER, ogEmdDioCounter Counter32 } ogEmdDioIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the Digital I/O status table" ::= { ogEmdDioEntry 1 } ogEmdDioEmd OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The EMD this Digital I/O relates to." ::= { ogEmdDioEntry 2 } ogEmdDioName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this Digital I/O." ::= { ogEmdDioEntry 3 } ogEmdDioDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of this Digital I/O." ::= { ogEmdDioEntry 4 } ogEmdDioType OBJECT-TYPE SYNTAX INTEGER { ttlInputOutput(1), highVoltageOutput(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Digital I/O type (TTL Input/Output or High-Voltage Output)." ::= { ogEmdDioEntry 5 } ogEmdDioDirection OBJECT-TYPE SYNTAX INTEGER { output(1), input(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of the Digital I/O (Input or Output)" ::= { ogEmdDioEntry 6 } ogEmdDioState OBJECT-TYPE SYNTAX INTEGER { high(1), low(2), unavailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The electrical state value of the Digital I/O (Low or High)" ::= { ogEmdDioEntry 7 } ogEmdDioTriggerMode OBJECT-TYPE SYNTAX INTEGER { invalid(1), risingEdge(2), fallingEdge(3), risingFallingEdge(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Trigger Mode of the Digital I/O" ::= { ogEmdDioEntry 8 } ogEmdDioCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The trigger counter of this Digital I/O" ::= { ogEmdDioEntry 9 } ogNetInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF NetInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This devices network interface status table." ::= { ogStatus2 12 } ogNetInterfaceEntry OBJECT-TYPE SYNTAX NetInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "EMD status entry" INDEX { ogNetInterfaceIndex } ::= { ogNetInterfaceTable 1 } NetInterfaceEntry ::= SEQUENCE { ogNetInterfaceIndex Integer32, ogNetInterfaceName DisplayString, ogNetInterfaceType INTEGER, ogNetInterfaceState INTEGER, ogNetInterfaceFailoverState INTEGER } ogNetInterfaceIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the network interface status table" ::= { ogNetInterfaceEntry 1 } ogNetInterfaceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of a network interface." ::= { ogNetInterfaceEntry 2 } ogNetInterfaceType OBJECT-TYPE SYNTAX INTEGER { unavailable(1), ethernet(2), wifi(3), cellModem(4), v92Modem(5), vpn(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this network interface entry." ::= { ogNetInterfaceEntry 3 } ogNetInterfaceState OBJECT-TYPE SYNTAX INTEGER { unavailable(1), down(2), starting(3), up(4), stopping(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this network interface entry." ::= { ogNetInterfaceEntry 4 } ogNetInterfaceFailoverState OBJECT-TYPE SYNTAX INTEGER { active(1), failed(2), dormant(3), standby(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The failover status of this interface. The primary interface is either active or failed. The secondary interface is either standby, dormant or active." ::= { ogNetInterfaceEntry 5 } ogPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF PowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entity's Power Supply table." ::= { ogStatus2 13 } ogPowerSupplyEntry OBJECT-TYPE SYNTAX PowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Supply status entry" INDEX { ogPowerSupplyIndex } ::= { ogPowerSupplyTable 1 } PowerSupplyEntry ::= SEQUENCE { ogPowerSupplyIndex Integer32, ogPowerSupplyName DisplayString, ogPowerSupplyInputVoltage Integer32, ogPowerSupplyOutputCurrent Integer32, ogPowerSupplyTemperature Integer32 } ogPowerSupplyIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the Power Supply status table" ::= { ogPowerSupplyEntry 1 } ogPowerSupplyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the Power Supply." ::= { ogPowerSupplyEntry 2 } ogPowerSupplyInputVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "volts" MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage of the Power Supply" ::= { ogPowerSupplyEntry 3 } ogPowerSupplyOutputCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.01 Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "Output current of the Power Supply" ::= { ogPowerSupplyEntry 4 } ogPowerSupplyTemperature OBJECT-TYPE SYNTAX Integer32 UNITS "degrees celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the Power Supply" ::= { ogPowerSupplyEntry 5 } ogUpsTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths Uninterruptable Power Supply (UPS) status table." ::= { ogStatus2 14 } ogUpsEntry OBJECT-TYPE SYNTAX UpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Digital I/O status entry" INDEX { ogUpsIndex } ::= { ogUpsTable 1 } UpsEntry ::= SEQUENCE { ogUpsIndex Integer32, ogUpsName DisplayString, ogUpsDescription DisplayString, ogUpsType DisplayString, ogUpsLogEnabled INTEGER, ogUpsConnectType INTEGER, ogUpsState INTEGER, ogUpsTemperature Integer32, ogUpsHumidity Integer32, ogUpsBatteryState INTEGER, ogUpsBatteryRunTime Integer32, ogUpsBatteryRunTimeLow Integer32, ogUpsBatteryRunTimeRestart Integer32, ogUpsBatteryCharge Integer32, ogUpsBatteryVoltage Integer32, ogUpsBatteryNominalVoltage Integer32, ogUpsBatteryCurrent Integer32, ogUpsBatteryNominalCurrent Integer32, ogUpsBatteryTemperature Integer32, ogUpsInputFrequency Integer32, ogUpsInputNominalFrequency Integer32, ogUpsInputVoltage Integer32, ogUpsInputNominalVoltage Integer32, ogUpsInputCurrent Integer32, ogUpsInputNominalCurrent Integer32, ogUpsOutputFrequency Integer32, ogUpsOutputNominalFrequency Integer32, ogUpsOutputVoltage Integer32, ogUpsOutputNominalVoltage Integer32, ogUpsOutputCurrent Integer32, ogUpsOutputNominalCurrent Integer32, ogUpsOutputLoad Integer32, ogUpsOutputPower Integer32, ogUpsOutputTruePower Integer32, ogUpsCounter Counter32 } ogUpsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the UPS status table." ::= { ogUpsEntry 1 } ogUpsName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this UPS." ::= { ogUpsEntry 2 } ogUpsDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of this UPS." ::= { ogUpsEntry 3 } ogUpsType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS driver type." ::= { ogUpsEntry 4 } ogUpsLogEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The logging status of the UPS" ::= { ogUpsEntry 5 } ogUpsConnectType OBJECT-TYPE SYNTAX INTEGER { unknown(1), usb(2), http(3), https(4), snmp(5), serial(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "How the UPS device is being monitored." ::= { ogUpsEntry 6 } ogUpsState OBJECT-TYPE SYNTAX INTEGER { unknown(1), onLine(2), onBattery(3), lowBattery(4), onBypass(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state the UPS is running in." ::= { ogUpsEntry 7 } ogUpsTemperature OBJECT-TYPE SYNTAX Integer32 UNITS "degrees" MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS temperature. Negative if unavailable." ::= { ogUpsEntry 8 } ogUpsHumidity OBJECT-TYPE SYNTAX Integer32 UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS humidity. Negative if unavailable." ::= { ogUpsEntry 9 } ogUpsBatteryState OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), warning(3), low(4), depleted(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the UPS battery." ::= { ogUpsEntry 10 } ogUpsBatteryRunTime OBJECT-TYPE SYNTAX Integer32 (-1..31449600) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Battery runtime (seconds). Negative if unavailable" ::= { ogUpsEntry 11 } ogUpsBatteryRunTimeLow OBJECT-TYPE SYNTAX Integer32 (-1..31449600) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated remaining battery runtime when UPS switches to Low Battery. Negative if unavailable." ::= { ogUpsEntry 12 } ogUpsBatteryRunTimeRestart OBJECT-TYPE SYNTAX Integer32 (-1..31449600) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum battery runtime for UPS restart after power-off (seconds). Negative if unavailable." ::= { ogUpsEntry 13 } ogUpsBatteryCharge OBJECT-TYPE SYNTAX Integer32 (-1..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated percent of Battery charge remaining. Negative if unavailable." ::= { ogUpsEntry 14 } ogUpsBatteryVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Volt DC" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the current battery voltage. Negative if unavailable." ::= { ogUpsEntry 15 } ogUpsBatteryNominalVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Volt DC" MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal battery voltage (V). Negative if unavailable." ::= { ogUpsEntry 16 } ogUpsBatteryCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Amp DC" MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS battery current. Negative if unavailable." ::= { ogUpsEntry 17 } ogUpsBatteryNominalCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Amp DC" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal UPS battery current. Negative if unavailable." ::= { ogUpsEntry 18 } ogUpsBatteryTemperature OBJECT-TYPE SYNTAX Integer32 UNITS "degrees" MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS battery temperature. Negative if unavailable." ::= { ogUpsEntry 19 } ogUpsInputFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Input line frequency (Hz). Negative if unavailable." ::= { ogUpsEntry 20 } ogUpsInputNominalFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal input line frequency (Hz). Negative if unavailable." ::= { ogUpsEntry 21 } ogUpsInputVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the UPS input voltage. Negative if unavailable." ::= { ogUpsEntry 22 } ogUpsInputNominalVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal input voltage. Negative if unavailable." ::= { ogUpsEntry 23 } ogUpsInputCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The input current. Negative if unavailable." ::= { ogUpsEntry 24 } ogUpsInputNominalCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal input current. Negative if unavailable." ::= { ogUpsEntry 25 } ogUpsOutputFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Output line frequency (Hz). Negative if unavailable." ::= { ogUpsEntry 26 } ogUpsOutputNominalFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal output line frequency (Hz). Negative if unavailable." ::= { ogUpsEntry 27 } ogUpsOutputVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the UPS output voltage. Negative if unavailable." ::= { ogUpsEntry 28 } ogUpsOutputNominalVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal magnitude of the UPS output voltage. Negative if unavailable." ::= { ogUpsEntry 29 } ogUpsOutputCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the UPS input current. Negative if unavailable." ::= { ogUpsEntry 30 } ogUpsOutputNominalCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal magnitude of the UPS input current. Negative if unavailable." ::= { ogUpsEntry 31 } ogUpsOutputLoad OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated percent of UPS power capacity being used." ::= { ogUpsEntry 32 } ogUpsOutputPower OBJECT-TYPE SYNTAX Integer32 UNITS "Volt-Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of apparent power (Volt-Amps). Negative if unavailable." ::= { ogUpsEntry 33 } ogUpsOutputTruePower OBJECT-TYPE SYNTAX Integer32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of real power (Watts). Negative if unavailable." ::= { ogUpsEntry 34 } ogUpsCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alerts triggered on the UPS" ::= { ogUpsEntry 35 } ogRpcTable OBJECT-TYPE SYNTAX SEQUENCE OF RpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entity's Remote Power Controller (RPC) table." ::= { ogStatus2 15 } ogRpcEntry OBJECT-TYPE SYNTAX RpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RPC status entry" INDEX { ogRpcIndex } ::= { ogRpcTable 1 } RpcEntry ::= SEQUENCE { ogRpcIndex Integer32, ogRpcName DisplayString, ogRpcDescription DisplayString, ogRpcType DisplayString, ogRpcLogEnabled INTEGER, ogRpcOutletTotal Counter32, ogRpcMaxTemperature Integer32, ogRpcConnectType INTEGER, ogRpcInputFrequency Integer32, ogRpcInputVoltage Integer32, ogRpcInputCurrent Integer32, ogRpcCounter Counter32 } ogRpcIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the RPC status table" ::= { ogRpcEntry 1 } ogRpcName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the RPC device." ::= { ogRpcEntry 2 } ogRpcDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description for the RPC device." ::= { ogRpcEntry 3 } ogRpcType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A type for the RPC device." ::= { ogRpcEntry 4 } ogRpcLogEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The logging status of the RPC" ::= { ogRpcEntry 5 } ogRpcOutletTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outlets on this RPC" ::= { ogRpcEntry 6 } ogRpcMaxTemperature OBJECT-TYPE SYNTAX Integer32 UNITS "degrees" MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum temperature on the RPC" ::= { ogRpcEntry 7 } ogRpcConnectType OBJECT-TYPE SYNTAX INTEGER { serial(1), network(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "How the RPC device is connected." ::= { ogRpcEntry 8 } ogRpcInputFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Input line frequency (Hz). Negative if unavailable." ::= { ogRpcEntry 9 } ogRpcInputVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the RPC input voltage. Negative if unavailable." ::= { ogRpcEntry 10 } ogRpcInputCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The input current. Negative if unavailable." ::= { ogRpcEntry 11 } ogRpcCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of alerts triggered on the RPC" ::= { ogRpcEntry 12 } ogRpcOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF RpcOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This RPC's outlet table." ::= { ogStatus2 16 } ogRpcOutletEntry OBJECT-TYPE SYNTAX RpcOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RPC Outlet status entry" INDEX { ogRpcIndex, ogRpcOutletIndex } ::= { ogRpcOutletTable 1 } RpcOutletEntry ::= SEQUENCE { ogRpcOutletIndex Integer32, ogRpcOutletRpc OBJECT IDENTIFIER, ogRpcOutletName DisplayString, ogRpcOutletState INTEGER, ogRpcOutletFrequency Integer32, ogRpcOutletVoltage Integer32, ogRpcOutletCurrent Integer32, ogRpcOutletLoad Integer32 } ogRpcOutletIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the RPC outlet table" ::= { ogRpcOutletEntry 1 } ogRpcOutletRpc OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The RPC this outlet belongs to" ::= { ogRpcOutletEntry 2 } ogRpcOutletName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the RPC outlet." ::= { ogRpcOutletEntry 3 } ogRpcOutletState OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), transitioning(3), unavailable(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The power status of the RPC outlet" ::= { ogRpcOutletEntry 4 } ogRpcOutletFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Output line frequency (Hz). Negative if unavailable." ::= { ogRpcOutletEntry 5 } ogRpcOutletVoltage OBJECT-TYPE SYNTAX Integer32 (-1..2640) UNITS "0.01 Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage on this outlet. Negative if unavailable." ::= { ogRpcOutletEntry 6 } ogRpcOutletCurrent OBJECT-TYPE SYNTAX Integer32 (-1..25500) UNITS "0.01 Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "Current measured on this outlet. Negative if unavailable." ::= { ogRpcOutletEntry 7 } ogRpcOutletLoad OBJECT-TYPE SYNTAX Integer32 (-1..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated percent of RPC outlet power capacity being used." ::= { ogRpcOutletEntry 8 } ogCellModemTable OBJECT-TYPE SYNTAX SEQUENCE OF CellModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths cellular modem status table." ::= { ogStatus2 17 } ogCellModemEntry OBJECT-TYPE SYNTAX CellModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A cellular modem status entry." INDEX { ogCellModemIndex } ::= { ogCellModemTable 1 } CellModemEntry ::= SEQUENCE { ogCellModemIndex Integer32, ogCellModemVendor DisplayString, ogCellModemModel DisplayString, ogCellModemEnabled INTEGER, ogCellModemConnected INTEGER, ogCellModemNetwork DisplayString, ogCellModemRegistered INTEGER, ogCellModemTower Integer32, ogCellModemRadioTechnology INTEGER, ogCellModemApn DisplayString, ogCellModem3gRssi Integer32, ogCellModem4gRssi Integer32, ogCellModemSessionTime Counter32, ogCellModemSelectedSimCard Counter32, ogCellModemTemperature Integer32, ogCellModemCounter Counter32, ogCellModemIMSI DisplayString } ogCellModemIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the cellular modem status entry." ::= { ogCellModemEntry 1 } ogCellModemVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Manufacturer ID of Cellular Modem." ::= { ogCellModemEntry 2 } ogCellModemModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Cellular Modem model name." ::= { ogCellModemEntry 3 } ogCellModemEnabled OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The enabled state of the modem." ::= { ogCellModemEntry 4 } ogCellModemConnected OBJECT-TYPE SYNTAX INTEGER { connected(1), disconnected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connected state of the modem." ::= { ogCellModemEntry 5 } ogCellModemNetwork OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the network provider." ::= { ogCellModemEntry 6 } ogCellModemRegistered OBJECT-TYPE SYNTAX INTEGER { registered(1), unregistered(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The registration state of the modem." ::= { ogCellModemEntry 7 } ogCellModemTower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current cellular tower ID." ::= { ogCellModemEntry 8 } ogCellModemRadioTechnology OBJECT-TYPE SYNTAX INTEGER { unavailable(1), cdma(2), evdo(3), gsm(4), umts(5), lte(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current Radio Access Technology being used" ::= { ogCellModemEntry 9 } ogCellModemApn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The APN configured for this cellmodem." ::= { ogCellModemEntry 10 } ogCellModem3gRssi OBJECT-TYPE SYNTAX Integer32 (-99..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The current 3G Received Signal Strength (RSSI) if applicable." ::= { ogCellModemEntry 11 } ogCellModem4gRssi OBJECT-TYPE SYNTAX Integer32 (-99..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The current 4G Received Signal Strength (RSSI) if applicable." ::= { ogCellModemEntry 12 } ogCellModemSessionTime OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds the modem session has been up for." ::= { ogCellModemEntry 13 } ogCellModemSelectedSimCard OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SIM card currently being used by this modem." ::= { ogCellModemEntry 14 } ogCellModemTemperature OBJECT-TYPE SYNTAX Integer32 UNITS "degrees" MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature of the Cellular Modem." ::= { ogCellModemEntry 15 } ogCellModemCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of alerts the modem has triggered." ::= { ogCellModemEntry 16 } ogCellModemIMSI OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IMSI of the SIM currently in use by the Cellular Modem." ::= { ogCellModemEntry 17 } ogWifiClientTable OBJECT-TYPE SYNTAX SEQUENCE OF WifiClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths wireless client status table." ::= { ogStatus2 18 } ogWifiClientEntry OBJECT-TYPE SYNTAX WifiClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A wireless client status entry." INDEX { ogWifiClientIndex } ::= { ogWifiClientTable 1 } WifiClientEntry ::= SEQUENCE { ogWifiClientIndex Integer32, ogWifiClientInterface DisplayString, ogWifiClientEnabled INTEGER, ogWifiClientEssid DisplayString, ogWifiClientIeeeMode INTEGER, ogWifiClientMode INTEGER, ogWifiClientFrequency Unsigned32, ogWifiClientApMac DisplayString, ogWifiClientBitRate Unsigned32, ogWifiClientTxPower Integer32, ogWifiClientLinkQuality Unsigned32, ogWifiClientRssi Integer32, ogWifiClientRxInvalidNwid Counter32, ogWifiClientRxInvalidCrypt Counter32, ogWifiClientRxInvalidFrag Counter32, ogWifiClientRxInvalidRetries Counter32, ogWifiClientRxInvalidMisc Counter32, ogWifiClientMissedBeacon Counter32, ogWifiClientCounter Counter32 } ogWifiClientIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the wireless client status entry." ::= { ogWifiClientEntry 1 } ogWifiClientInterface OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless client network interface name." ::= { ogWifiClientEntry 2 } ogWifiClientEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless client enabled state" ::= { ogWifiClientEntry 3 } ogWifiClientEssid OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ESSID this wireless client is currently associated with." ::= { ogWifiClientEntry 4 } ogWifiClientIeeeMode OBJECT-TYPE SYNTAX INTEGER { unavailable(1), ieee802Dot11B(2), ieee802Dot11BG(3), ieee802Dot11BGN(4), ieee802Dot11ABGN(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The IEEE 802.11 mode of this wireless client." ::= { ogWifiClientEntry 5 } ogWifiClientMode OBJECT-TYPE SYNTAX INTEGER { unavailable(1), managed(2), adhoc(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operating mode of this wireless client." ::= { ogWifiClientEntry 6 } ogWifiClientFrequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "0.0001 THz" MAX-ACCESS read-only STATUS current DESCRIPTION "The current frequency of this wireless client." ::= { ogWifiClientEntry 7 } ogWifiClientApMac OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Access Point ID this wireless client is associated with." ::= { ogWifiClientEntry 8 } ogWifiClientBitRate OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "The current bit-rate of this wireless client." ::= { ogWifiClientEntry 9 } ogWifiClientTxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx-Power of this wireless client." ::= { ogWifiClientEntry 10 } ogWifiClientLinkQuality OBJECT-TYPE SYNTAX Unsigned32 UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The normalized link quality of this wireless client." ::= { ogWifiClientEntry 11 } ogWifiClientRssi OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Signal Level of this wireless client." ::= { ogWifiClientEntry 12 } ogWifiClientRxInvalidNwid OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of invalid Network ID's for this wireless client." ::= { ogWifiClientEntry 13 } ogWifiClientRxInvalidCrypt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of invalid crypt's for this wireless client." ::= { ogWifiClientEntry 14 } ogWifiClientRxInvalidFrag OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of invalid frag's for this wireless client." ::= { ogWifiClientEntry 15 } ogWifiClientRxInvalidRetries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of invalid retries for this wireless client." ::= { ogWifiClientEntry 16 } ogWifiClientRxInvalidMisc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of invalid misc's for this wireless client." ::= { ogWifiClientEntry 17 } ogWifiClientMissedBeacon OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of missed beacon's for this wireless client." ::= { ogWifiClientEntry 18 } ogWifiClientCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of alerts triggered by this wireless client." ::= { ogWifiClientEntry 19 } ogWifiApTable OBJECT-TYPE SYNTAX SEQUENCE OF WifiApEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths wireless interface status table." ::= { ogStatus2 19 } ogWifiApEntry OBJECT-TYPE SYNTAX WifiApEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A wireless interface status entry" INDEX { ogWifiApIndex } ::= { ogWifiApTable 1 } WifiApEntry ::= SEQUENCE { ogWifiApIndex Integer32, ogWifiApInterface DisplayString, ogWifiApEnabled INTEGER, ogWifiApSsid DisplayString, ogWifiApIeeeMode INTEGER, ogWifiApFrequency Unsigned32, ogWifiApTxPower Integer32, ogWifiApCounter Counter32 } ogWifiApIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the wireless server status entry." ::= { ogWifiApEntry 1 } ogWifiApInterface OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless access point network interface name." ::= { ogWifiApEntry 2 } ogWifiApEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The enabled status of the wireless server." ::= { ogWifiApEntry 3 } ogWifiApSsid OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The SSID for this wireless access point." ::= { ogWifiApEntry 4 } ogWifiApIeeeMode OBJECT-TYPE SYNTAX INTEGER { unavailable(1), ieee802Dot11B(2), ieee802Dot11BG(3), ieee802Dot11BGN(4), ieee802Dot11ABGN(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The IEEE 802.11 mode of this wireless access point." ::= { ogWifiApEntry 5 } ogWifiApFrequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "0.0001 THz" MAX-ACCESS read-only STATUS current DESCRIPTION "The current frequency of this wireless access point." ::= { ogWifiApEntry 6 } ogWifiApTxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx-Power of this wireless access point." ::= { ogWifiApEntry 7 } ogWifiApCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of alerts triggered by this wireless access point." ::= { ogWifiApEntry 8 } ogWifiApClientTable OBJECT-TYPE SYNTAX SEQUENCE OF WifiApClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This RPC's outlet table." ::= { ogStatus2 20 } ogWifiApClientEntry OBJECT-TYPE SYNTAX WifiApClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RPC Outlet status entry" INDEX { ogWifiApIndex, ogWifiApClientIndex } ::= { ogWifiApClientTable 1 } WifiApClientEntry ::= SEQUENCE { ogWifiApClientIndex Integer32, ogWifiApClientAp OBJECT IDENTIFIER, ogWifiApClientMac DisplayString, ogWifiApClientInactiveTime Counter32, ogWifiApClientRxBytes Counter32, ogWifiApClientRxPackets Counter32, ogWifiApClientTxBytes Counter32, ogWifiApClientTxPackets Counter32, ogWifiApClientRssi Integer32, ogWifiApClientTxBitRate Unsigned32 } ogWifiApClientIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the wireless AP client table" ::= { ogWifiApClientEntry 1 } ogWifiApClientAp OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless AP this client is assiciated with." ::= { ogWifiApClientEntry 2 } ogWifiApClientMac OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the Access Point this wireless client is associated with." ::= { ogWifiApClientEntry 3 } ogWifiApClientInactiveTime OBJECT-TYPE SYNTAX Counter32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Inactive Time for this wireless client." ::= { ogWifiApClientEntry 4 } ogWifiApClientRxBytes OBJECT-TYPE SYNTAX Counter32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received bytes for this wireless client." ::= { ogWifiApClientEntry 5 } ogWifiApClientRxPackets OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received packets for this wireless client." ::= { ogWifiApClientEntry 6 } ogWifiApClientTxBytes OBJECT-TYPE SYNTAX Counter32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted bytes for this wireless client." ::= { ogWifiApClientEntry 7 } ogWifiApClientTxPackets OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted packets for this wireless client." ::= { ogWifiApClientEntry 8 } ogWifiApClientRssi OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Signal Level of this wireless client." ::= { ogWifiApClientEntry 9 } ogWifiApClientTxBitRate OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "The current transmission bit-rate of this wireless client." ::= { ogWifiApClientEntry 10 } ogCheckTable OBJECT-TYPE SYNTAX SEQUENCE OF CheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ths auto-response check table." ::= { ogStatus2 21 } ogCheckEntry OBJECT-TYPE SYNTAX CheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An auto-response check entry" INDEX { ogCheckIndex } ::= { ogCheckTable 1 } CheckEntry ::= SEQUENCE { ogCheckIndex Integer32, ogCheckName DisplayString, ogCheckRepeatTimeout Integer32, ogCheckResetTimeout Integer32, ogCheckType INTEGER, ogCheckTriggerActions Counter32, ogCheckResolveActions Counter32 } ogCheckIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the auto-response rule" ::= { ogCheckEntry 1 } ogCheckName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this auto-response rule." ::= { ogCheckEntry 2 } ogCheckRepeatTimeout OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum seconds before trigger actions can be repeated for this auto-response." ::= { ogCheckEntry 3 } ogCheckResetTimeout OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum seconds after resolution before this auto-response can be triggered again." ::= { ogCheckEntry 4 } ogCheckType OBJECT-TYPE SYNTAX INTEGER { unknown(1), serialSignal(2), serialUser(3), serialPattern(4), hostPing(5), hostService(6), hostUser(7), webUser(8), envTemperature(9), envHumidity(10), dioInput(11), netInterface(12), powerSupplyInputVoltage(13), powerSupplyOutputCurrent(14), powerSupplyTemperature(15), upsInputVoltage(16), upsBatteryCharge(17), upsBatteryTemperature(18), upsOutputLoad(19), upsInputFrequency(20), upsStateOnBattery(21), upsStateLowBattery(22), rpcInput(23), rpcOutletState(24), rpcOutletOutput(25), cellMessage(26), cellData(27), cellSignal(28), cellApn(29), cellTower(30), cellNetwork(31), wirelessClientConnect(32), wirelessClientSignal(33), wirelessApAssociation(34), wirelessApAuthentication(35), dialPoolHealth(36), cliUser(37), custom(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The auto-response check type" ::= { ogCheckEntry 5 } ogCheckTriggerActions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Trigger Actions configured for the auto-response." ::= { ogCheckEntry 6 } ogCheckResolveActions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Resolve Actions configured for the auto-response." ::= { ogCheckEntry 7 } ogCheckDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF CheckDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auto-response device reference table." ::= { ogStatus2 22 } ogCheckDeviceEntry OBJECT-TYPE SYNTAX CheckDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RPC Outlet status entry" INDEX { ogCheckIndex, ogCheckDeviceIndex } ::= { ogCheckDeviceTable 1 } CheckDeviceEntry ::= SEQUENCE { ogCheckDeviceIndex Integer32, ogCheckDeviceCheck OBJECT IDENTIFIER, ogCheckDeviceName DisplayString, ogCheckDeviceRef DisplayString } ogCheckDeviceIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the auto-response device outlet table" ::= { ogCheckDeviceEntry 1 } ogCheckDeviceCheck OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The check this device is associated with." ::= { ogCheckDeviceEntry 2 } ogCheckDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of a device pertaining to the auto-reponse." ::= { ogCheckDeviceEntry 3 } ogCheckDeviceRef OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The reference ID of the device pertaining to the auto-reponse." ::= { ogCheckDeviceEntry 4 } -- -- The Alarm Group -- ogAlarm OBJECT IDENTIFIER ::= { ogStatus2 23 } ogAlarmLogTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm history table." ::= { ogAlarm 1 } ogAlarmLogEntry OBJECT-TYPE SYNTAX AlarmLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An alarm entry." INDEX { ogAlarmLogIndex } ::= { ogAlarmLogTable 1 } AlarmLogEntry ::= SEQUENCE { ogAlarmLogIndex Integer32, ogAlarmEventId Integer32, ogAlarmName DisplayString, ogAlarmCheck Integer32, ogAlarmInstance Integer32, ogAlarmTime DateAndTime, ogAlarmType INTEGER, ogAlarmSummary DisplayString, ogAlarmDevice DisplayString, ogAlarmUser DisplayString, ogAlarmTriggerValue Integer32, ogAlarmCurrentValue Integer32, ogAlarmPreviousValue Integer32, ogAlarmState INTEGER } ogAlarmLogIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the current alarm table of this alarm." ::= { ogAlarmLogEntry 1 } ogAlarmEventId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique event ID for this alarm." ::= { ogAlarmLogEntry 2 } ogAlarmName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The check ID that this alarm pertains to." ::= { ogAlarmLogEntry 3 } ogAlarmCheck OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The auto-response index this alarm relates to." ::= { ogAlarmLogEntry 4 } ogAlarmInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The reference index for this alarm instance." ::= { ogAlarmLogEntry 5 } ogAlarmTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The UTC date and time for when this alarm was created." ::= { ogAlarmLogEntry 6 } ogAlarmType OBJECT-TYPE SYNTAX INTEGER { serialSignalCts(1), serialSignalDcd(2), serialSignalDsr(3), serialPatternTx(4), serialPatternRx(5), serialUserSession(6), hostPingDown(7), hostPingUp(8), hostServiceDown(9), hostServiceUp(10), hostUserSession(11), webUserSession(12), envTemperatureLow(13), envTemperatureHigh(14), envHumidityLow(15), envHumidityHigh(16), dioSignalOpened(17), dioSignalClosed(18), netInterfaceDown(19), netInterfaceStarting(20), netInterfaceUp(21), netInterfaceStopping(22), powerSupplyInputVoltageLow(23), powerSupplyInputVoltageHigh(24), powerSupplyOutputCurrentLow(25), powerSupplyOutputCurrentHigh(26), powerSupplyTemperatureLow(27), powerSupplyTemperatureHigh(28), upsTemperatureHigh(29), upsTemperatureLow(30), upsHumidityHigh(31), upsHumidityLow(32), upsOnBattery(33), upsLowBattery(34), upsBatteryChargeLow(35), upsBatteryChargeHigh(36), upsBatteryVoltageLow(37), upsBatteryVoltageHigh(38), upsBatteryCurrentLow(39), upsBatteryCurrentHigh(40), upsBatteryTemperatureLow(41), upsBatteryTemperatureHigh(42), upsInputFrequencyLow(43), upsInputFrequencyHigh(44), upsInputVoltageLow(45), upsInputVoltageHigh(46), upsInputCurrentLow(47), upsInputCurrentHigh(48), upsOutputFrequencyLow(49), upsOutputFrequencyHigh(50), upsOutputVoltageLow(51), upsOutputVoltageHigh(52), upsOutputCurrentLow(53), upsOutputCurrentHigh(54), upsOutputLoadLow(55), upsOutputLoadHigh(56), upsOutputPowerLow(57), upsOutputPowerHigh(58), upsOutputTruePowerLow(59), upsOutputTruePowerHigh(60), rpcInputFrequencyLow(61), rpcInputFrequencyHigh(62), rpcInputVoltageLow(63), rpcInputVoltageHigh(64), rpcInputCurrentLow(65), rpcInputCurrentHigh(66), rpcOutletFrequencyHigh(67), rpcOutletFrequencyLow(68), rpcOutletVoltageHigh(69), rpcOutletVoltageLow(70), rpcOutletCurrentHigh(71), rpcOutletCurrentLow(72), rpcOutletStateOff(73), rpcOutletStateOn(74), cellDataUsage(75), cellMessageReceived(76), cellSignalLow(77), cellSignalHigh(78), cellApnChanged(79), cellTowerChanged(80), cellNetworkChanged(81), wirelessClientConnected(82), wirelessClientDisconnected(83), wirelessClientSignalLow(84), wirelessClientSignalHigh(85), wirelessApAssociation(86), wirelessApDisassociation(87), wirelessApAuthenticationFailure(88), dialPoolHealth(89), cliUserSession(90), customCheckFailure(255), unknown(65535) } MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to an Alarm Type Object." ::= { ogAlarmLogEntry 7 } ogAlarmSummary OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The human readable summary of this alarm." ::= { ogAlarmLogEntry 8 } ogAlarmDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The device ID that this alarm pertains to." ::= { ogAlarmLogEntry 9 } ogAlarmUser OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user ID that this alarm pertains to." ::= { ogAlarmLogEntry 10 } ogAlarmTriggerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold value which triggers the alarm." ::= { ogAlarmLogEntry 11 } ogAlarmCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value as of the time of this entry." ::= { ogAlarmLogEntry 12 } ogAlarmPreviousValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The former value of this entry." ::= { ogAlarmLogEntry 13 } ogAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), triggered(2), resolving(3), waiting(4), disabled(5), unresolvable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The effective alarm state." ::= { ogAlarmLogEntry 14 } ogCurrentAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF CurrentAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm history table." ::= { ogAlarm 2 } ogCurrentAlarmEntry OBJECT-TYPE SYNTAX CurrentAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An alarm entry." INDEX { ogCurrentAlarmIndex } ::= { ogCurrentAlarmTable 1 } CurrentAlarmEntry ::= SEQUENCE { ogCurrentAlarmIndex Integer32, ogCurrentAlarmEventId Integer32, ogCurrentAlarmName DisplayString, ogCurrentAlarmCheck Integer32, ogCurrentAlarmInstance Integer32, ogCurrentAlarmTime DateAndTime, ogCurrentAlarmType INTEGER, ogCurrentAlarmSummary DisplayString, ogCurrentAlarmDevice DisplayString, ogCurrentAlarmUser DisplayString, ogCurrentAlarmTriggerValue Integer32, ogCurrentAlarmCurrentValue Integer32, ogCurrentAlarmPreviousValue Integer32, ogCurrentAlarmState INTEGER } ogCurrentAlarmIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index within the current alarm table of this alarm." ::= { ogCurrentAlarmEntry 1 } ogCurrentAlarmEventId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique event ID for this alarm." ::= { ogCurrentAlarmEntry 2 } ogCurrentAlarmName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the check this alarm pertains to." ::= { ogCurrentAlarmEntry 3 } ogCurrentAlarmCheck OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The auto-response index this alarm relates to." ::= { ogCurrentAlarmEntry 4 } ogCurrentAlarmInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The reference index for this alarm instance." ::= { ogCurrentAlarmEntry 5 } ogCurrentAlarmTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The UTC date and time for when this alarm was created." ::= { ogCurrentAlarmEntry 6 } ogCurrentAlarmType OBJECT-TYPE SYNTAX INTEGER { serialSignalCts(1), serialSignalDcd(2), serialSignalDsr(3), serialPatternTx(4), serialPatternRx(5), serialUserSession(6), hostPingDown(7), hostPingUp(8), hostServiceDown(9), hostServiceUp(10), hostUserSession(11), webUserSession(12), envTemperatureLow(13), envTemperatureHigh(14), envHumidityLow(15), envHumidityHigh(16), dioSignalOpened(17), dioSignalClosed(18), netInterfaceDown(19), netInterfaceStarting(20), netInterfaceUp(21), netInterfaceStopping(22), powerSupplyInputVoltageLow(23), powerSupplyInputVoltageHigh(24), powerSupplyOutputCurrentLow(25), powerSupplyOutputCurrentHigh(26), powerSupplyTemperatureLow(27), powerSupplyTemperatureHigh(28), upsTemperatureHigh(29), upsTemperatureLow(30), upsHumidityHigh(31), upsHumidityLow(32), upsOnBattery(33), upsLowBattery(34), upsBatteryChargeLow(35), upsBatteryChargeHigh(36), upsBatteryVoltageLow(37), upsBatteryVoltageHigh(38), upsBatteryCurrentLow(39), upsBatteryCurrentHigh(40), upsBatteryTemperatureLow(41), upsBatteryTemperatureHigh(42), upsInputFrequencyLow(43), upsInputFrequencyHigh(44), upsInputVoltageLow(45), upsInputVoltageHigh(46), upsInputCurrentLow(47), upsInputCurrentHigh(48), upsOutputFrequencyLow(49), upsOutputFrequencyHigh(50), upsOutputVoltageLow(51), upsOutputVoltageHigh(52), upsOutputCurrentLow(53), upsOutputCurrentHigh(54), upsOutputLoadLow(55), upsOutputLoadHigh(56), upsOutputPowerLow(57), upsOutputPowerHigh(58), upsOutputTruePowerLow(59), upsOutputTruePowerHigh(60), rpcInputFrequencyLow(61), rpcInputFrequencyHigh(62), rpcInputVoltageLow(63), rpcInputVoltageHigh(64), rpcInputCurrentLow(65), rpcInputCurrentHigh(66), rpcOutletFrequencyHigh(67), rpcOutletFrequencyLow(68), rpcOutletVoltageHigh(69), rpcOutletVoltageLow(70), rpcOutletCurrentHigh(71), rpcOutletCurrentLow(72), rpcOutletStateOff(73), rpcOutletStateOn(74), cellDataUsage(75), cellMessageReceived(76), cellSignalLow(77), cellSignalHigh(78), cellApnChanged(79), cellTowerChanged(80), cellNetworkChanged(81), wirelessClientConnected(82), wirelessClientDisconnected(83), wirelessClientSignalLow(84), wirelessClientSignalHigh(85), wirelessApAssociation(86), wirelessApDisassociation(87), wirelessApAuthenticationFailure(88), dialPoolHealth(89), cliUserSession(90), customCheckFailure(255), unknown(65535) } MAX-ACCESS read-only STATUS current DESCRIPTION "The specific Alarm Type." ::= { ogCurrentAlarmEntry 7 } ogCurrentAlarmSummary OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A readable summary of this alarm." ::= { ogCurrentAlarmEntry 8 } ogCurrentAlarmDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the device this alarm pertains to." ::= { ogCurrentAlarmEntry 9 } ogCurrentAlarmUser OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the user this alarm pertains to." ::= { ogCurrentAlarmEntry 10 } ogCurrentAlarmTriggerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold value which triggers the alarm." ::= { ogCurrentAlarmEntry 11 } ogCurrentAlarmCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value as of the time of this entry." ::= { ogCurrentAlarmEntry 12 } ogCurrentAlarmPreviousValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The former value of this entry." ::= { ogCurrentAlarmEntry 13 } ogCurrentAlarmState OBJECT-TYPE SYNTAX INTEGER { normal(1), triggered(2), resolving(3), waiting(4), disabled(5), unresolvable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The effective alarm state." ::= { ogCurrentAlarmEntry 14 } -- Notifications ogStatus2NotificationPrefix OBJECT IDENTIFIER ::= { ogStatus2 100 } ogMibNotifications OBJECT IDENTIFIER ::= { ogStatus2NotificationPrefix 0 } ogSerialSignalNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a serial signal changes." ::= { ogMibNotifications 1 } ogSerialPatternNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a pattern is matched on a serial port ." ::= { ogMibNotifications 2 } ogSerialUserNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a user logs in or out of a serial console." ::= { ogMibNotifications 3 } ogHostPingNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a host stops or resumes responding to a ping." ::= { ogMibNotifications 4 } ogHostServiceNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a host service stops or resumes." ::= { ogMibNotifications 5 } ogHostUserNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a user logs in or out of a network host." ::= { ogMibNotifications 6 } ogWebUserNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a user logs in or out of the web interface." ::= { ogMibNotifications 7 } ogEmdTemperatureNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a temperature event occurs" ::= { ogMibNotifications 8 } ogEmdHumidityNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a humidity event occurs" ::= { ogMibNotifications 9 } ogEmdDioNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a Digital I/O input event occurs" ::= { ogMibNotifications 10 } ogPowerSupplyInputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a power supply voltage alarm occurs" ::= { ogMibNotifications 11 } ogPowerSupplyOutputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a power supply voltage alarm occurs" ::= { ogMibNotifications 12 } ogPowerSupplyTempNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a power supply voltage alarm occurs" ::= { ogMibNotifications 13 } ogUpsNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a UPS alarm occurs" ::= { ogMibNotifications 14 } ogUpsBatteryNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a UPS battery alarm occurs" ::= { ogMibNotifications 15 } ogUpsInputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a UPS input alarm occurs" ::= { ogMibNotifications 16 } ogUpsOutputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a UPS output alarm occurs" ::= { ogMibNotifications 17 } ogRpcInputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a RPC input alarm occurs" ::= { ogMibNotifications 18 } ogRpcOutputNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a RPC output alarm occurs" ::= { ogMibNotifications 19 } ogRpcOutletNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a RPC output alarm occurs" ::= { ogMibNotifications 20 } ogNetInterfaceNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a network interface event occurs." ::= { ogMibNotifications 21 } ogCellDataNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a cellular data alarm occurs." ::= { ogMibNotifications 22 } ogCellMessageNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when an SMS command alarm occurs." ::= { ogMibNotifications 23 } ogCellSignalNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a cellular signal alarm occurs." ::= { ogMibNotifications 24 } ogCellApnNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a cellular APN alarm occurs." ::= { ogMibNotifications 25 } ogCellTowerNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a cellular tower alarm occurs." ::= { ogMibNotifications 26 } ogCellNetworkNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a cellular network alarm occurs." ::= { ogMibNotifications 27 } ogWifiClientConnectNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a wireless client connects or disconnects." ::= { ogMibNotifications 28 } ogWifiClientSignalNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a wireless client signal changes." ::= { ogMibNotifications 29 } ogWifiApAssociationNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a wireless client connects or disconnects to this AP." ::= { ogMibNotifications 30 } ogWifiApAuthNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a wireless client fails to authenticate with this AP." ::= { ogMibNotifications 31 } ogDialPoolHealthNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when dial-pool health alarm occurs." ::= { ogMibNotifications 32 } ogCustomNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a custom check is triggered." ::= { ogMibNotifications 33 } ogCliUserSessionNotification NOTIFICATION-TYPE OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState } STATUS current DESCRIPTION "The notification sent when a user logs in or out of a CLI session." ::= { ogMibNotifications 34 } -- End notifications -- conformance information ogStatus2Conformance OBJECT IDENTIFIER ::= { ogStatus2 65535 } ogStatus2Compliances OBJECT IDENTIFIER ::= { ogStatus2Conformance 1 } ogStatus2Groups OBJECT IDENTIFIER ::= { ogStatus2Conformance 2 } -- compliance statements ogStatus2Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the Opengear status MIB." MODULE -- this module MANDATORY-GROUPS { ogBasicStatusGroup, ogBasicAlarmGroup, ogBasicNotificationGroup } ::= { ogStatus2Compliances 1 } -- units of conformance ogBasicStatusGroup OBJECT-GROUP OBJECTS { ogFirmwareVersion, ogSerialNumber, ogSerialPortLabel, ogSerialPortSpeed, ogSerialPortDataBits, ogSerialPortParity, ogSerialPortStopBits, ogSerialPortFlowControl, ogSerialPortMode, ogSerialPortLogLevel, ogSerialPortRxBytes, ogSerialPortTxBytes, ogSerialPortFramingErrors, ogSerialPortParityErrors, ogSerialPortOverrunErrors, ogSerialPortBreaks, ogSerialPortDCD, ogSerialPortDTR, ogSerialPortDSR, ogSerialPortCTS, ogSerialPortRTS, ogSerialUserStartTime, ogSerialUserPort, ogSerialUserLabel, ogSerialUserName, ogHostName, ogHostIpV4Address, ogHostIpV6Address, ogHostServiceHost, ogHostServiceType, ogHostServicePort, ogHostServiceStatus, ogHostServiceCounter, ogHostUserHost, ogHostUserStartTime, ogHostUserAddress, ogHostUserHostName, ogHostUserName, ogWebUserStartTime, ogWebUserName, ogWebUserSourceAddress, ogWebUserSourcePort, ogEmdName, ogEmdDescription, ogEmdEnabled, ogEmdLogEnabled, ogEmdConnectType, ogEmdTemperatureTotal, ogEmdHumidityTotal, ogEmdDioInputTotal, ogEmdTemperatureEmd, ogEmdTemperatureName, ogEmdTemperatureDescription, ogEmdTemperatureValue, ogEmdTemperatureCounter, ogEmdHumidityEmd, ogEmdHumidityName, ogEmdHumidityDescription, ogEmdHumidityValue, ogEmdHumidityCounter, ogEmdDioEmd, ogEmdDioName, ogEmdDioDescription, ogEmdDioType, ogEmdDioDirection, ogEmdDioState, ogEmdDioTriggerMode, ogEmdDioCounter, ogNetInterfaceName, ogNetInterfaceType, ogNetInterfaceState, ogNetInterfaceFailoverState, ogPowerSupplyName, ogPowerSupplyInputVoltage, ogPowerSupplyOutputCurrent, ogPowerSupplyTemperature, ogUpsName, ogUpsDescription, ogUpsType, ogUpsLogEnabled, ogUpsConnectType, ogUpsState, ogUpsTemperature, ogUpsHumidity, ogUpsBatteryState, ogUpsBatteryRunTime, ogUpsBatteryRunTimeLow, ogUpsBatteryRunTimeRestart, ogUpsBatteryCharge, ogUpsBatteryVoltage, ogUpsBatteryNominalVoltage, ogUpsBatteryCurrent, ogUpsBatteryNominalCurrent, ogUpsBatteryTemperature, ogUpsInputFrequency, ogUpsInputNominalFrequency, ogUpsInputVoltage, ogUpsInputNominalVoltage, ogUpsInputCurrent, ogUpsInputNominalCurrent, ogUpsOutputFrequency, ogUpsOutputNominalFrequency, ogUpsOutputVoltage, ogUpsOutputNominalVoltage, ogUpsOutputCurrent, ogUpsOutputNominalCurrent, ogUpsOutputLoad, ogUpsOutputPower, ogUpsOutputTruePower, ogUpsCounter, ogRpcName, ogRpcDescription, ogRpcType, ogRpcLogEnabled, ogRpcOutletTotal, ogRpcMaxTemperature, ogRpcConnectType, ogRpcInputFrequency, ogRpcInputVoltage, ogRpcInputCurrent, ogRpcCounter, ogRpcOutletRpc, ogRpcOutletName, ogRpcOutletState, ogRpcOutletFrequency, ogRpcOutletCurrent, ogRpcOutletVoltage, ogRpcOutletLoad, ogCellModemVendor, ogCellModemModel, ogCellModemEnabled, ogCellModemConnected, ogCellModemNetwork, ogCellModemRegistered, ogCellModemTower, ogCellModemRadioTechnology, ogCellModemApn, ogCellModem3gRssi, ogCellModem4gRssi, ogCellModemSessionTime, ogCellModemSelectedSimCard, ogCellModemTemperature, ogCellModemCounter, ogCellModemIMSI, ogWifiClientInterface, ogWifiClientEnabled, ogWifiClientEssid, ogWifiClientIeeeMode, ogWifiClientMode, ogWifiClientFrequency, ogWifiClientApMac, ogWifiClientBitRate, ogWifiClientTxPower, ogWifiClientLinkQuality, ogWifiClientRssi, ogWifiClientRxInvalidNwid, ogWifiClientRxInvalidCrypt, ogWifiClientRxInvalidFrag, ogWifiClientRxInvalidRetries, ogWifiClientRxInvalidMisc, ogWifiClientMissedBeacon, ogWifiClientCounter, ogWifiApInterface, ogWifiApEnabled, ogWifiApSsid, ogWifiApIeeeMode, ogWifiApFrequency, ogWifiApTxPower, ogWifiApCounter, ogWifiApClientAp, ogWifiApClientMac, ogWifiApClientInactiveTime, ogWifiApClientRxBytes, ogWifiApClientRxPackets, ogWifiApClientTxBytes, ogWifiApClientTxPackets, ogWifiApClientRssi, ogWifiApClientTxBitRate, ogCheckName, ogCheckRepeatTimeout, ogCheckResetTimeout, ogCheckType, ogCheckTriggerActions, ogCheckResolveActions, ogCheckDeviceCheck, ogCheckDeviceName, ogCheckDeviceRef } STATUS current DESCRIPTION "A collection of objects to retrieve Opengear statistics." ::= { ogStatus2Groups 1 } ogBasicAlarmGroup OBJECT-GROUP OBJECTS { ogAlarmEventId, ogAlarmName, ogAlarmCheck, ogAlarmInstance, ogAlarmTime, ogAlarmType, ogAlarmSummary, ogAlarmDevice, ogAlarmUser, ogAlarmTriggerValue, ogAlarmCurrentValue, ogAlarmPreviousValue, ogAlarmState, ogCurrentAlarmEventId, ogCurrentAlarmName, ogCurrentAlarmCheck, ogCurrentAlarmInstance, ogCurrentAlarmTime, ogCurrentAlarmType, ogCurrentAlarmSummary, ogCurrentAlarmDevice, ogCurrentAlarmUser, ogCurrentAlarmTriggerValue, ogCurrentAlarmCurrentValue, ogCurrentAlarmPreviousValue, ogCurrentAlarmState } STATUS current DESCRIPTION "A collection of objects to report Opengear alarms." ::= { ogStatus2Groups 2 } ogBasicNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { ogSerialSignalNotification, ogSerialPatternNotification, ogSerialUserNotification, ogHostPingNotification, ogHostServiceNotification, ogHostUserNotification, ogWebUserNotification, ogEmdDioNotification, ogEmdTemperatureNotification, ogEmdHumidityNotification, ogPowerSupplyInputNotification, ogPowerSupplyOutputNotification, ogPowerSupplyTempNotification, ogUpsNotification, ogUpsInputNotification, ogUpsBatteryNotification, ogUpsOutputNotification, ogRpcInputNotification, ogRpcOutputNotification, ogRpcOutletNotification, ogNetInterfaceNotification, ogCellDataNotification, ogCellMessageNotification, ogCellSignalNotification, ogCellApnNotification, ogCellTowerNotification, ogCellNetworkNotification, ogWifiClientConnectNotification, ogWifiClientSignalNotification, ogWifiApAssociationNotification, ogWifiApAuthNotification, ogDialPoolHealthNotification, ogCustomNotification, ogCliUserSessionNotification } STATUS current DESCRIPTION "A collection of notifications for the status system." ::= { ogStatus2Groups 3 } END