OGTRAP-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 enterprises FROM RFC1155-SMI; opengear OBJECT IDENTIFIER ::= { enterprises 25049 } ogLegacyMgmt OBJECT IDENTIFIER ::= { opengear 2 } ogConnectMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 10 } ogSignalMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 11 } ogPatternMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 12 } ogSensorMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 13 } ogHostMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 14 } ogFailoverMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 15 } ogNetUpsMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 16 } ogDataMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 17 } -- Serial port connection traps. ogConnectMibObjects OBJECT IDENTIFIER ::= { ogConnectMib 10 } ogconnEvent OBJECT IDENTIFIER ::= { ogConnectMibObjects 1 } ogconnEventTable OBJECT IDENTIFIER ::= { ogconnEvent 1 } ogconnEventEntry OBJECT IDENTIFIER ::= { ogconnEventTable 1 } ogconnEventUsername OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The user pertaining to the connection event" ::= { ogconnEventEntry 10 } ogconnEventType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of connection event" ::= { ogconnEventEntry 11 } ogconnEventPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Serial port number on which this connection applies" ::= { ogconnEventEntry 12 } ogconnEventPortLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for the serial port where the connection occurred." ::= { ogconnEventEntry 13 } ogconnEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogconnEventUsername, ogconnEventType, ogconnEventPortNumber, ogconnEventPortLabel } DESCRIPTION "The alert sent when a user connection event occurs." ::= 1001 -- Serial port signal trap ogSignalMibObjects OBJECT IDENTIFIER ::= { ogSignalMib 10 } ogsgnlEvent OBJECT IDENTIFIER ::= { ogSignalMibObjects 1 } ogsgnlEventTable OBJECT IDENTIFIER ::= { ogsgnlEvent 1 } ogsgnlEventEntry OBJECT IDENTIFIER ::= { ogsgnlEventTable 1 } ogsgnlEventType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The particular signal which changed" ::= { ogsgnlEventEntry 10 } ogsgnlEventState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The current signal state" ::= { ogsgnlEventEntry 11 } ogsgnlEventPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Serial port number on which this signal applies" ::= { ogsgnlEventEntry 12 } ogsgnlEventPortLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for the serial port where the signal applies." ::= { ogsgnlEventEntry 13 } ogsgnlEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogsgnlEventType, ogsgnlEventState, ogsgnlEventPortNumber, ogsgnlEventPortLabel } DESCRIPTION "The alert sent when a signal change occurs" ::= 1002 -- Serial console pattern traps ogPatternMibObjects OBJECT IDENTIFIER ::= { ogPatternMib 10 } ogpatnEvent OBJECT IDENTIFIER ::= { ogPatternMibObjects 1 } ogpatnEventTable OBJECT IDENTIFIER ::= { ogpatnEvent 1 } ogpatnEventEntry OBJECT IDENTIFIER ::= { ogpatnEventTable 1 } ogpatnEventDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A description of the matches purpose" ::= { ogpatnEventEntry 10 } ogpatnEventText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The full text which matched the pattern" ::= { ogpatnEventEntry 11 } ogpatnEventPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Serial port number on which the pattern matched" ::= { ogpatnEventEntry 12 } ogpatnEventPortLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for the serial port where pattern match occurred" ::= { ogpatnEventEntry 13 } ogpatnEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogpatnEventDescription, ogpatnEventText, ogpatnEventPortNumber, ogpatnEventPortLabel } DESCRIPTION "The alert sent when a pre-defined pattern was matched text in a consoles serial character stream" ::= 1003 -- Sensor traps ogSensorMibObjects OBJECT IDENTIFIER ::= { ogSensorMib 10 } ogsensStatus OBJECT IDENTIFIER ::= { ogSensorMibObjects 1 } ogsensStatusTable OBJECT IDENTIFIER ::= { ogsensStatus 1 } ogsensStatusEntry OBJECT IDENTIFIER ::= { ogsensStatusTable 1 } ogsensStatusName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the device pertaining to the status event" ::= { ogsensStatusEntry 10 } ogsensStatusDevType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of device pertaining to the status event" ::= { ogsensStatusEntry 11 } ogsensStatusType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of sensor pertaining to the status event" ::= { ogsensStatusEntry 12 } ogsensStatusValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of the sensor pertaining to the status event" ::= { ogsensStatusEntry 13 } ogsensStatusOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogsensStatusName, ogsensStatusDevType, ogsensStatusType, ogsensStatusValue } DESCRIPTION "The trap sent when a sensor event occurs" ::= 1004 -- Host traps ogHostMibObjects OBJECT IDENTIFIER ::= { ogHostMib 10 } oghostEvent OBJECT IDENTIFIER ::= { ogHostMibObjects 1 } oghostEventTable OBJECT IDENTIFIER ::= { oghostEvent 1 } oghostEventEntry OBJECT IDENTIFIER ::= { oghostEventTable 1 } oghostEventUsername OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The user pertaining to the connection event" ::= { oghostEventEntry 10 } oghostEventType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of connection event" ::= { oghostEventEntry 11 } oghostEventAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The address of the host to which this connection applies." ::= { oghostEventEntry 12 } oghostEventDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The description of the host to which this connection applies." ::= { oghostEventEntry 13 } oghostEventProtocol OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The internet protocl to which this connection applies." ::= { oghostEventEntry 14 } oghostEventPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The applicable port number of the host." ::= { oghostEventEntry 15 } oghostEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { oghostEventUsername, oghostEventType, oghostEventAddress, oghostEventDescription, oghostEventProtocol, oghostEventPort } DESCRIPTION "The alert sent when a user connection event occurs" ::= 2001 -- Failover traps ogFailoverMibObjects OBJECT IDENTIFIER ::= { ogFailoverMib 10 } ogfovrEvent OBJECT IDENTIFIER ::= { ogFailoverMibObjects 1 } ogfovrEventTable OBJECT IDENTIFIER ::= { ogfovrEvent 1 } ogfovrEventEntry OBJECT IDENTIFIER ::= { ogfovrEventTable 1 } ogfovrEventPrimary OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the network interface which failed" ::= { ogfovrEventEntry 10 } ogfovrEventSecondary OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the network interface which was connected instead" ::= { ogfovrEventEntry 11 } ogfovrEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogfovrEventPrimary, ogfovrEventSecondary } DESCRIPTION "The alert sent when a network failover event occurs" ::= 2002 -- Ups trap ogNetUpsMibObjects OBJECT IDENTIFIER ::= { ogNetUpsMib 10 } ognupsEvent OBJECT IDENTIFIER ::= { ogNetUpsMibObjects 1 } ognupsEventTable OBJECT IDENTIFIER ::= { ognupsEvent 1 } ognupsEventEntry OBJECT IDENTIFIER ::= { ognupsEventTable 1 } ognupsEventName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the UPS pertaining to the status event" ::= { ognupsEventEntry 10 } ognupsEventType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of status event" ::= { ognupsEventEntry 11 } ognupsEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ognupsEventName, ognupsEventType } DESCRIPTION "The alert sent when a UPS status event occurs" ::= 2003 -- Data Usage trap ogDataMibObjects OBJECT IDENTIFIER ::= { ogDataMib 10 } ogdataEvent OBJECT IDENTIFIER ::= { ogDataMibObjects 1 } ogdataEventTable OBJECT IDENTIFIER ::= { ogdataEvent 1 } ogdataEventEntry OBJECT IDENTIFIER ::= { ogdataEventTable 1 } ogdataEventBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of bytes which triggers this usage alert" ::= { ogdataEventEntry 10 } ogdataEventSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time in seconds over which bytes are measured" ::= { ogdataEventEntry 11 } ogdataEventDevice OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The ID for the interface thos pertains to" ::= { ogdataEventEntry 12 } ogdataEventState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Whether data usage alert is on (1) or off (0)" ::= { ogdataEventEntry 13 } ogdataEventOccurred TRAP-TYPE ENTERPRISE opengear VARIABLES { ogdataEventBytes, ogdataEventSeconds, ogdataEventDevice, ogdataEventState } DESCRIPTION "The trap sent when a data usage alert occurs" ::= 2004 END