-- ***************************************************************** -- SONET MIB -- ***************************************************************** SL-SONET-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter64, Gauge32 FROM SNMPv2-SMI DisplayString, TruthValue, RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF InterfaceIndex, ifIndex FROM IF-MIB PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB sitelight FROM SL-NE-MIB; slSonetMib MODULE-IDENTITY LAST-UPDATED "200008280000Z" ORGANIZATION "PacketLight Networks Ltd." CONTACT-INFO "Omri_Viner@PacketLight.com" DESCRIPTION "This MIB module describes the SiteLight SONET Service. The mib contains the extensions required for the rfc2558." ::= { sitelight 6 } SignalLabel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "STS path signal label -- one byte, C2, class A, is allocated to indicate the construction of the STS SPE. The following hex values of the C2 byte has been defined." SYNTAX INTEGER { sigUnequipped(0), -- Unequipped signal (no path originate equipment) sigEquipped(1), -- Equipped signal (standard payload) sigPathFloatVt(2), -- Floating VT mode sigPathLoackedVt(3), -- Locked VT mode sigPathAsynchDs3(4), -- Asynchronous mapping for DS3 sigPathSyntran(5), -- Mapping byte observable SYNTRAN sigPathAsyncDs4na(18), -- Asynchronous mapping for 139.264 Mbps sigPathAtm(19), -- Mapping for ATM sigPathDqdb(20), -- Mapping for DQDB sigPathFddi(21), -- Asynchronous mapping for FDDI sigPathHdlc(22), -- HDLC-Over-SONET Mapping sigPathGfp(27) -- GFP Mapping } slSonetConfig OBJECT IDENTIFIER ::= { slSonetMib 1} slSonetOh OBJECT IDENTIFIER ::= { slSonetMib 2 } -- slSonetPmMib OBJECT IDENTIFIER ::= {slSonetMib 3} -- slSonetAlarmsMib OBJECT IDENTIFIER ::= {slSonetMib 4} -- slSonetApsMib OBJECT IDENTIFIER ::= {slSonetMib 5} slSonetPos OBJECT IDENTIFIER ::= { slSonetMib 6 } slSonetAls OBJECT IDENTIFIER ::= { slSonetMib 7 } slSonetFs OBJECT IDENTIFIER ::= { slSonetMib 8 } slSonetTraps OBJECT IDENTIFIER ::= { slSonetMib 11 } slSonetOhTrace OBJECT IDENTIFIER ::= {slSonetOh 1} -- Trace Message slSonetOhSl OBJECT IDENTIFIER ::= {slSonetOh 2} -- Signal Label slSonetOhTraps OBJECT IDENTIFIER ::= {slSonetOh 3} -- Mismatch Traps ------------------------------ -- -- Sonet Config table -- ------------------------------ slSonetConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH configuration table. This table has objects for configuring sonet lines." ::= { slSonetConfig 1 } slSonetConfigEntry OBJECT-TYPE SYNTAX SlSonetConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table. There is an entry for each SONET line in the table. Entries are automatically created for an ifType value of sonet(39). 'ifAdminStatus' from the ifTable must be used to enable or disable a line. By default, the line state is down." INDEX { ifIndex } ::= { slSonetConfigTable 1 } SlSonetConfigEntry ::= SEQUENCE { slSonetConfigFrameScramble INTEGER, slSonetConfigType INTEGER, -- deprecated slSonetConfigDccSelection INTEGER, slSonetResetAllCounters INTEGER, slSonetPortThresholdTrapEnable INTEGER, slSonetConfigSdThreshold INTEGER, slSonetConfigSfThreshold INTEGER, slSonetCompression INTEGER, slSonetOverheadTunneling INTEGER, slSonetLopBitmask Counter64, -- deprecated slSonetTdmTrunk TruthValue, slSonetFsApply INTEGER, -- deprecated slSonetTxLte INTEGER, slSonetReceivedLte INTEGER, slSonetResetPmThreshold INTEGER, slSonetResetAlsParams INTEGER, slSonetTransceiverType INTEGER, slSonetTransceiverMedia INTEGER } slSonetConfigFrameScramble OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to disable or enable the Scrambling option in SONET line. Please refer to GR-253-CORE for frame scrambling." REFERENCE "GR-253-CORE" DEFVAL { enabled } ::= {slSonetConfigEntry 1} slSonetConfigType OBJECT-TYPE SYNTAX INTEGER { sonetSts3(1), -- deprecated sonetSts3c(2), -- deprecated sonetSts12(3), -- deprecated sonetSts12c(4), -- deprecated sonetSts48c(5), sonetSts3cx4(6), -- deprecated sonetSts48(7), -- deprecated sonetSts3cx16(8), -- deprecated sonetSts3x16(9), -- deprecated sonetSts12cx4(10), -- deprecated sonetSts12x4(11), -- deprecated sonetSts192c(12), sonetStsOther(13) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object represents the configured line type for Trunks: sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk) sonetSts192c(12) - 1 x Sts192 (10Gb Trunk) sonetStsOther(13) - for OC-n interfaces see slSonetFsTable." ::= {slSonetConfigEntry 2} slSonetConfigDccSelection OBJECT-TYPE SYNTAX INTEGER { sonetLineDcc(1), sonetSectionDcc(2), sonetInband(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the DCC type." ::= {slSonetConfigEntry 3 } slSonetResetAllCounters OBJECT-TYPE SYNTAX INTEGER { resetCounters(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to 1 will cause all of the counters (performance regsters) on this SONET interface to be initialized to zero (0)." REFERENCE "ANSI T1.231-1997 clause 9.1.5.1." ::= { slSonetConfigEntry 4 } slSonetPortThresholdTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates whether threshold traps should be generated for this SONET interface." REFERENCE "ANSI T1.231-1997 clause 9.1.5.2." DEFVAL { disabled } ::= { slSonetConfigEntry 5 } slSonetConfigSdThreshold OBJECT-TYPE SYNTAX INTEGER (5..9) MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to -n where n is between 5 and 9 (read-write)." DEFVAL {5} ::= { slSonetConfigEntry 6 } slSonetConfigSfThreshold OBJECT-TYPE SYNTAX INTEGER (3..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5. (read-write)" DEFVAL {3} ::= { slSonetConfigEntry 7 } slSonetCompression OBJECT-TYPE SYNTAX INTEGER { uncompress(0), posCompress32(1), posCompress16(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object applies only for trunk ports. It specifies if the packets should be compressed. 0 - Means no POS compression, 1 - Means POS compression with CRC-32. 2 - Means POS compression with CRC-16. Note that the two connected trunks should be configured to the same value. Note also that the BW calculation of the OC-n should be changed according to this value." ::= { slSonetConfigEntry 9 } slSonetOverheadTunneling OBJECT-TYPE SYNTAX INTEGER { none(0), lineDcc(1), k1k2(2), full(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The section and line overhead tunneling configuration: none(0) - no tunneling support lineDcc(1) - line DCC tunneling k1k2(2) - line DCC + protection k byte full(3) - all transport overhead bytes are tunneled" ::= { slSonetConfigEntry 10 } slSonetLopBitmask OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current -- deprecated DESCRIPTION "The LOP status. Each bit of the bits represent the status of the LOP alarm in corresponding STS. For a path with more than a single STS, only the value of the first STS in the path is relevant. This object is relevant only for the OC-N cards and not for the Trunk. In the next future this object will be replaced with an object of a new table that shall describe the OC-N frame structure." ::= { slSonetConfigEntry 11 } slSonetTdmTrunk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only to the OC-n ports. TRUE - means that the OC-n port is used as a TDM Trunk. FLASE - means normal OC-n port." ::= { slSonetConfigEntry 12 } slSonetFsApply OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write -- deprecated STATUS current DESCRIPTION "Writing to this object activate the slSonetFsTable setting. This allow the NMS to do many changes to the slSonetFsTable and then APPLY them at once. This prevent from going through unconsistent steps. This object always returns the value 0." ::= { slSonetConfigEntry 13 } slSonetTxLte OBJECT-TYPE SYNTAX INTEGER { ssb00(1), -- SONET ssb10(2), -- SDH auto(5) -- Tx what is detected } MAX-ACCESS read-write STATUS current DESCRIPTION "The SS bits to transmit (bits 5,6 in H1,H1*)." ::= { slSonetConfigEntry 14 } slSonetReceivedLte OBJECT-TYPE SYNTAX INTEGER { ssb00(1), -- SONET ssb10(2), -- SDH ssb01(3), -- other ssb11(4), -- other ssbinv(5) -- invalid } MAX-ACCESS read-only STATUS current DESCRIPTION "The detected LTE type, according to the received SS bits (bits 5,6 in H1,H1*)." ::= { slSonetConfigEntry 15 } slSonetResetPmThreshold OBJECT-TYPE SYNTAX INTEGER { resetCounters(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to 1 will reset the PM threshold parameters to the factory defaults." REFERENCE "ANSI T1.231-1997 clause 9.1.5.1." ::= { slSonetConfigEntry 16 } slSonetResetAlsParams OBJECT-TYPE SYNTAX INTEGER { resetCounters(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to 1 will reset the ALS parameters to the factory defaults." REFERENCE "ANSI T1.231-1997 clause 9.1.5.1." ::= { slSonetConfigEntry 17 } slSonetTransceiverType OBJECT-TYPE SYNTAX INTEGER { none(1), shortWave(2), -- 850nm longWave(3) -- 1310nm } MAX-ACCESS read-only STATUS current DESCRIPTION "The tranceiver type." ::= { slSonetConfigEntry 18 } slSonetTransceiverMedia OBJECT-TYPE SYNTAX INTEGER { none(1), -- sm(2), -- Single Mode mm(3) -- Multi Mode } MAX-ACCESS read-only STATUS current DESCRIPTION "The tranceiver media." ::= { slSonetConfigEntry 19 } -- ---------------------------------------------------------------- -- -- Sonet Trace Table -- -- ---------------------------------------------------------------- slSonetTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH Trace table. This table contains objects for tracing the sonet section and path." ::= { slSonetOhTrace 1 } slSonetTraceEntry OBJECT-TYPE SYNTAX SlSonetTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the trace table. Entries exist for active sonet interfaces. The objects in this table are used to verify continued connection between the two ends of the line." INDEX { ifIndex } ::= { slSonetTraceTable 1 } SlSonetTraceEntry ::= SEQUENCE { slSonetTraceMode INTEGER, slSonetTraceToTransmit DisplayString, slSonetTraceToExpect DisplayString, slSonetTraceFailure TruthValue, slSonetTraceReceived DisplayString } slSonetTraceMode OBJECT-TYPE SYNTAX INTEGER { enable(1), -- notification and rdi disable(2), -- no notification and no rdi monitoring(3) -- only notification and no rdi } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the Trace Message Mode." REFERENCE "GR-253-CORE" ::= { slSonetTraceEntry 1 } slSonetTraceToTransmit OBJECT-TYPE SYNTAX DisplayString (SIZE(0..62)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sonet Trace To Transmit. This is string that is transmitted to perform Sonet trace diagnostics. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed. The Agent is responsible to pad the end of the string with ." REFERENCE "GR-253-CORE" ::= { slSonetTraceEntry 2 } slSonetTraceToExpect OBJECT-TYPE SYNTAX DisplayString (SIZE(0..62)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sonet Trace Massage To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'slSonetTraceFailure' indicates whether a trace mismatch occurred. The default value is a zero-length string. The Agent is responsible to pad the end of the string with ." REFERENCE "GR-253-CORE" ::= { slSonetTraceEntry 3 } slSonetTraceFailure OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is set to 'true' when Sonet Section received trace does not match the 'slSonetTraceToExpect'." REFERENCE "GR-253-CORE" ::= { slSonetTraceEntry 4 } slSonetTraceReceived OBJECT-TYPE SYNTAX DisplayString (SIZE(0..62)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to view the Sonet Trace Message that is received by the receiving terminal. The Agent is responsible to pad the end of the string with ." REFERENCE "GR-253-CORE" ::= { slSonetTraceEntry 5 } -- ---------------------------------------------------------------- -- -- Signal Label Table -- -- ---------------------------------------------------------------- slSonetSlTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetSlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET/SDH Signal Label table. This table contains signal label for the sonet path." ::= { slSonetOhSl 1 } slSonetSlEntry OBJECT-TYPE SYNTAX SlSonetSlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET/SDH Signal Label table. The entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line." INDEX { ifIndex } ::= { slSonetSlTable 1 } SlSonetSlEntry ::= SEQUENCE { slSonetSlToTransmit SignalLabel, slSonetSlToExpect SignalLabel, slSonetSlFailure TruthValue, slSonetSlReceived INTEGER } slSonetSlToTransmit OBJECT-TYPE SYNTAX SignalLabel MAX-ACCESS read-write STATUS current DESCRIPTION "Sonet Signal Label To Transmit." REFERENCE "GR-253-CORE" ::= { slSonetSlEntry 2 } slSonetSlToExpect OBJECT-TYPE SYNTAX SignalLabel MAX-ACCESS read-write STATUS current DESCRIPTION "Sonet Signal Label To Expect." REFERENCE "GR-253-CORE" ::= { slSonetSlEntry 3 } slSonetSlFailure OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is set to 'true' when Sonet received signal label does not match the 'slSonetSlToExpect'." REFERENCE "GR-253-CORE" ::= { slSonetSlEntry 4 } slSonetSlReceived OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to view the Sonet Signal Label that is received by the receiving terminal." REFERENCE "GR-253-CORE" ::= { slSonetSlEntry 5 } -- ---------------------------------------------------------------- -- -- Packets Over Sonet/Sdh (POS) Performance Monitoring (PM) Table -- -- ---------------------------------------------------------------- slSonetPosTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetPosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POS PM Table." ::= { slSonetPos 1 } slSonetPosEntry OBJECT-TYPE SYNTAX SlSonetPosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries exist for active Trunk sonet lines ifType = pos(171). The objects in this table are used to moitor the POS layer." INDEX { ifIndex } ::= { slSonetPosTable 1 } SlSonetPosEntry ::= SEQUENCE { slSonetPosFcs Gauge32, slSonetPosAbort Gauge32, slSonetPosMinViolation Gauge32, slSonetPosMaxViolation Gauge32, slSonetPosRxfifoDiscard Gauge32, slSonetPosPacketReceived Counter64, slSonetPosPacketReceivedOk Counter64 } slSonetPosFcs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of FCS Errors." ::= { slSonetPosEntry 1 } slSonetPosAbort OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of Aborted packets." ::= { slSonetPosEntry 2 } slSonetPosMinViolation OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of Minimum length violation packets." ::= { slSonetPosEntry 3 } slSonetPosMaxViolation OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of Maximum length violation packets." ::= { slSonetPosEntry 4 } slSonetPosRxfifoDiscard OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of packets discarded due to RXFIFO error." ::= { slSonetPosEntry 5 } slSonetPosPacketReceived OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of packets received." ::= { slSonetPosEntry 6 } slSonetPosPacketReceivedOk OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The Number of error free packets." ::= { slSonetPosEntry 7 } -- ---------------------------------------------------------------- -- -- Automatic Laser Shutdown (ALS) Configuration Table -- -- ---------------------------------------------------------------- slSonetAlsTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetAlsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ALS configuration Table." ::= { slSonetAls 1 } slSonetAlsEntry OBJECT-TYPE SYNTAX SlSonetAlsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries exist for active sonet lines ifType = sonet(39). The objects in this table are used to configure the ALS algorithm." INDEX { ifIndex } ::= { slSonetAlsTable 1 } SlSonetAlsEntry ::= SEQUENCE { slSonetAlsMode INTEGER, slSonetLosDeclareTime INTEGER, slSonetTestPulseTime INTEGER, slSonetManualPulseTime INTEGER, slSonetAutomaticPulseTime INTEGER, slSonetAutomaticDelayTime INTEGER, slSonetLaserTestActivate INTEGER, slSonetLaserManualActivate INTEGER } slSonetAlsMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the ALS algorithm. Note that the if the Laser Admin Status is 'down' the ALS mechanism is not operational." ::= { slSonetAlsEntry 1 } slSonetLosDeclareTime OBJECT-TYPE SYNTAX INTEGER { ms500(1), -- 500 ms ms550(2), -- 550 ms ms600(3) -- 600 ms } MAX-ACCESS read-write STATUS current DESCRIPTION "Time to declare optical LOS present or clear: 550 +- 50 msec." ::= { slSonetAlsEntry 2 } slSonetTestPulseTime OBJECT-TYPE SYNTAX INTEGER { s80(1), -- 80 sec s90(2), -- 90 sec s100(3) -- 100 sec } MAX-ACCESS read-write STATUS current DESCRIPTION "Manual restart for test Pulse time (in manual restart) - 90+-10 sec." ::= { slSonetAlsEntry 3 } slSonetManualPulseTime OBJECT-TYPE SYNTAX INTEGER { ms1750(1), -- 1.75 Sec ms2000(2), -- 2.0 sec ms2250(3) -- 2.25 sec } MAX-ACCESS read-write STATUS current DESCRIPTION "Manual restart Pulse time (in manual mode) - 2+-0.25 sec." ::= { slSonetAlsEntry 4 } slSonetAutomaticPulseTime OBJECT-TYPE SYNTAX INTEGER { ms1750(1), -- 1.75 Sec ms2000(2), -- 2.0 sec ms2250(3) -- 2.25 sec } MAX-ACCESS read-write STATUS current DESCRIPTION "Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec." ::= { slSonetAlsEntry 5 } slSonetAutomaticDelayTime OBJECT-TYPE SYNTAX INTEGER (60..300) MAX-ACCESS read-write STATUS current DESCRIPTION "In Automatic mode. The delay between two laser re-activations." ::= { slSonetAlsEntry 6 } slSonetLaserTestActivate OBJECT-TYPE SYNTAX INTEGER { activate(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate the laser for test operation." ::= { slSonetAlsEntry 7 } slSonetLaserManualActivate OBJECT-TYPE SYNTAX INTEGER { activate(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate the laser manual operation." ::= { slSonetAlsEntry 8 } -- ---------------------------------------------------------------- -- -- Frame Structure Configuration Table -- -- ---------------------------------------------------------------- slSonetFsTable OBJECT-TYPE SYNTAX SEQUENCE OF SlSonetFsEntry MAX-ACCESS not-accessible -- deprecated STATUS current DESCRIPTION "The frame structure configuration Table. In order to define a new path the NMS should create and configure an entry in this table. The table is also used to monitor the status of the LOP alarm per path." ::= { slSonetFs 1 } slSonetFsEntry OBJECT-TYPE SYNTAX SlSonetFsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries exist for sonet paths ifType = sonet(39). The objects in this table are used to configure the frame structure. Each OC-N line interface shall maintain a static table with number of lines equal to the N. Initially the table will be initialized to STS-Nc." INDEX { slSonetFsIfIndex, slSonetFsSts } ::= { slSonetFsTable 1 } SlSonetFsEntry ::= SEQUENCE { slSonetFsIfIndex InterfaceIndex, slSonetFsSts INTEGER, slSonetFsWidth INTEGER, slSonetFsFullPathTermination TruthValue, slSonetFsGranularity INTEGER } slSonetFsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index." ::= { slSonetFsEntry 1 } slSonetFsSts OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the first STS in the path. Note that no all values are legal because there is no support for combus with mixed structure" ::= { slSonetFsEntry 2 } slSonetFsWidth OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number STS's in the path. The width is only valid for the first STS in the path. The other STSs of the path will have width=0." ::= { slSonetFsEntry 3 } slSonetFsFullPathTermination OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "FALSE - means partial path termination (only LOP alarm). TRUE - include full support for path Alarms and PM counters." ::= { slSonetFsEntry 4 } slSonetFsGranularity OBJECT-TYPE SYNTAX INTEGER { vc4(1), vc3(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This value is set by the NMS according to the configured frame structure. Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1). Otherwise the value should be vc3(2)." ::= { slSonetFsEntry 5 } -- ---------------------------------------------------------------- -- -- Sonet Traps -- -- ---------------------------------------------------------------- slSonetFsTableChange NOTIFICATION-TYPE OBJECTS { slSonetFsIfIndex } STATUS current DESCRIPTION "A slSonetFsTableChange trap is sent when the content of the slSonetFsTable is changed. This trap may be used by the NMS to identify the removal of path interfaces, or addition of new path interfaces" ::= { slSonetTraps 1 } END