-- File Name : PBI-MGSIGNALCHARACTERISTICS-MIB -- Date : Thu Sep 21 14:37:54 CST 2006 -- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6 PBI-MGSIGNALCHARACTERISTICS-MIB DEFINITIONS ::= BEGIN IMPORTS RowStatus, DisplayString FROM SNMPv2-TC DisplayString FROM RFC1213-MIB mg FROM PBI-MAIN-MIB MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI; mgSignalCharacteristics MODULE-IDENTITY LAST-UPDATED "200609210924Z" ORGANIZATION "Organization" CONTACT-INFO "Contact-info" DESCRIPTION "Description" REVISION "200609210924Z" DESCRIPTION "" ::= { mg 2 } tsOutTable OBJECT-TYPE SYNTAX SEQUENCE OF TsOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { mgSignalCharacteristics 1 } mgPATTable OBJECT-TYPE SYNTAX SEQUENCE OF MgPATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PSI/SI information relating to the PAT, reference ISO/IEC 13818-1 " ::= { mgSignalCharacteristics 2 } mgPMTTable OBJECT-TYPE SYNTAX SEQUENCE OF MgPMTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PSI/SI information relating to the PMT" ::= { mgSignalCharacteristics 3 } mgNITTable OBJECT-TYPE SYNTAX SEQUENCE OF MgNITEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PSI/SI information relating to the NIT" ::= { mgSignalCharacteristics 4 } mgSDTTable OBJECT-TYPE SYNTAX SEQUENCE OF MgSDTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PSI/SI information relating to the SDT, reference DVB 300-468" ::= { mgSignalCharacteristics 5 } mgFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF MgFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description" ::= { mgSignalCharacteristics 6 } mgCATTable OBJECT-TYPE SYNTAX SEQUENCE OF MgCATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PSI/SI information relating to the CAT, reference ISO/IEC 13818-1 " ::= { mgSignalCharacteristics 7 } tsInput OBJECT IDENTIFIER ::= { mgSignalCharacteristics 8 } mgBATTable OBJECT-TYPE SYNTAX SEQUENCE OF MgBATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " PSI/SI information relating to the BAT, reference ISO/IEC 13818-1 " ::= { mgSignalCharacteristics 9 } tsOutEntry OBJECT-TYPE SYNTAX TsOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row Description " INDEX { channelOutput } ::= { tsOutTable 1 } TsOutEntry ::= SEQUENCE { channelOutput INTEGER, bitRate INTEGER, packetSize INTEGER, transportStreamID INTEGER, otiginalNetworkID INTEGER, networkID INTEGER, bitrateThreshosdPercent INTEGER, outValidBitRate INTEGER } channelOutput OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "output channel number" ::= { tsOutEntry 1 } bitRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs" ::= { tsOutEntry 2 } packetSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Packet length, option: 188 or 204" ::= { tsOutEntry 3 } transportStreamID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1" ::= { tsOutEntry 4 } otiginalNetworkID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468" ::= { tsOutEntry 5 } networkID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468" ::= { tsOutEntry 6 } bitrateThreshosdPercent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "ts overflow percent value(0 - 100)" ::= { tsOutEntry 7 } outValidBitRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "transport stream out valid bit rate" ::= { tsOutEntry 8 } mgPATEntry OBJECT-TYPE SYNTAX MgPATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputPAT } ::= { mgPATTable 1 } MgPATEntry ::= SEQUENCE { channelInputPAT INTEGER, patSection DisplayString } channelInputPAT OBJECT-TYPE SYNTAX INTEGER ( -2147483648 .. 2147483647 ) MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgPATEntry 1 } patSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1 " ::= { mgPATEntry 2 } mgPMTEntry OBJECT-TYPE SYNTAX MgPMTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputPMT } ::= { mgPMTTable 1 } MgPMTEntry ::= SEQUENCE { channelInputPMT INTEGER, pmtProgramNumber INTEGER, pmtPID INTEGER, pmtSection DisplayString } channelInputPMT OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgPMTEntry 1 } pmtProgramNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The PMT program number as read from PMT,reference ISO/IEC 13818-1" ::= { mgPMTEntry 2 } pmtPID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The PMT PID as read from PMT,reference ISO/IEC 13818-1" ::= { mgPMTEntry 3 } pmtSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1" ::= { mgPMTEntry 4 } mgNITEntry OBJECT-TYPE SYNTAX MgNITEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputNIT } ::= { mgNITTable 1 } MgNITEntry ::= SEQUENCE { channelInputNIT INTEGER, networkType INTEGER, nitActualSection DisplayString, nitOhtersSection DisplayString } channelInputNIT OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgNITEntry 1 } networkType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The network type include two types: actual NIT and others NIT, reference DVB 300-468" ::= { mgNITEntry 2 } nitActualSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468" ::= { mgNITEntry 3 } nitOhtersSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468" ::= { mgNITEntry 4 } mgSDTEntry OBJECT-TYPE SYNTAX MgSDTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputSDT } ::= { mgSDTTable 1 } MgSDTEntry ::= SEQUENCE { channelInputSDT INTEGER, sdtSection DisplayString } channelInputSDT OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgSDTEntry 1 } sdtSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream relating to SDT seciton, reference DVB 300-468" ::= { mgSDTEntry 2 } mgFilterEntry OBJECT-TYPE SYNTAX MgFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputFilter } ::= { mgFilterTable 1 } MgFilterEntry ::= SEQUENCE { channelInputFilter INTEGER, oldPID DisplayString, newPID DisplayString, oldProgramNumber DisplayString, newProgramNumber DisplayString } channelInputFilter OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgFilterEntry 1 } oldPID OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The old PID will be filtered output" ::= { mgFilterEntry 2 } newPID OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The new PID is bulit according to old PID" ::= { mgFilterEntry 3 } oldProgramNumber OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The old program number,they come from PAT and will be filtered output" ::= { mgFilterEntry 4 } newProgramNumber OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The new program number, they are bulit and will be made a new PAT" ::= { mgFilterEntry 5 } mgCATEntry OBJECT-TYPE SYNTAX MgCATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelInputCAT } ::= { mgCATTable 1 } MgCATEntry ::= SEQUENCE { channelInputCAT INTEGER, catSection DisplayString } channelInputCAT OBJECT-TYPE SYNTAX INTEGER ( -2147483648 .. 2147483647 ) MAX-ACCESS read-write STATUS current DESCRIPTION "The physical input on which this transport stream appears" ::= { mgCATEntry 1 } catSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1 " ::= { mgCATEntry 2 } channelInput OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "channel number of input" ::= { tsInput 1 } stateLock OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "0xFFFF is lock, other is unlock" ::= { tsInput 2 } tsIdPreference OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "transport stream identifier" ::= { tsInput 3 } mgBATEntry OBJECT-TYPE SYNTAX MgBATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { channelBAT } ::= { mgBATTable 1 } MgBATEntry ::= SEQUENCE { channelBAT INTEGER, batSection DisplayString } channelBAT OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "specify channel of get BAT " ::= { mgBATEntry 1 } batSection OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1 " ::= { mgBATEntry 2 } END