        CELLULAR DEFINITIONS ::= BEGIN

                IMPORTS
                        OBJECT-GROUP
                                FROM SNMPv2-CONF
                        enterprises, Integer32, IpAddress,Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY
                                FROM SNMPv2-SMI
                        DisplayString, RowStatus, TruthValue, MacAddress
                                FROM SNMPv2-TC;

--
-- Node definitions
--
-- ********************************************************************
-- *  MODULE IDENTITY
-- ********************************************************************
-- The Enterprises Number
        peplink OBJECT IDENTIFIER ::= { enterprises 23695 }

        productMib  OBJECT IDENTIFIER ::= { peplink 200 }

        generalMib OBJECT IDENTIFIER ::= { productMib 1 }

        cellularMib MODULE-IDENTITY
                    LAST-UPDATED "201805071200Z"        -- 05 07, 2018 at 12:00 GMT
                    ORGANIZATION "PEPLINK"
                    CONTACT-INFO ""
                    DESCRIPTION
                        "MIB module for CELLULAR."
            ::= { generalMib 12 }

-- #####################################################################
--
-- **********************************************************************
-- *  MIB attribute OBJECT-TYPE definitions follow
-- **********************************************************************
        cellularSignalInfo OBJECT IDENTIFIER ::= { cellularMib 1 }

-- **********************************************************************
-- *  Table
-- **********************************************************************
        cellularSignalInfoTable OBJECT-TYPE
            SYNTAX SEQUENCE OF CellularSignalInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Cellular signal info table"
            ::= { cellularSignalInfo 1 }

            cellularSignalInfoEntry OBJECT-TYPE
            SYNTAX CellularSignalInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An entry in the cellularSignalInfoTable"
            INDEX { cellularSignalInfoId }
            ::= { cellularSignalInfoTable 1 }

            CellularSignalInfoEntry ::=
            SEQUENCE {
                cellularSignalInfoId
                    Integer32,
                cellularSignalInfoWanId
                    Integer32,
                cellularSignalRssi
                    Integer32,
                cellularSignalSnr
                    Integer32,
                cellularSignalSinr
                    Integer32,
                cellularSignalEcio
                    Integer32,
                cellularSignalRsrp
                    Integer32,
                cellularSignalRsrq
                    Integer32,
                cellularNetworkType
                    OCTET STRING,
                cellularBand
                    OCTET STRING,
                cellularLac
                    Integer32,
                cellularTac
                    Integer32,
		cellularENodeBId
                    Integer32
            }

            cellularSignalInfoId OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular signal info ID."
                ::= { cellularSignalInfoEntry 1 }

            cellularSignalInfoWanId OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular signal info WAN ID."
                ::= { cellularSignalInfoEntry 2 }

            cellularSignalRssi OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dBm"
                    MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular RSSI (units: dBm).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 3 }

            cellularSignalSnr OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dB"
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular SNR (units: dB).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 4 }

            cellularSignalSinr OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dB"
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular SINR (units: dB).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 5 }

            cellularSignalEcio OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dB"
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular Ec/Io (units: dB).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 6 }

            cellularSignalRsrp OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dBm"
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular RSRP (units: dBm).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 7 }

            cellularSignalRsrq OBJECT-TYPE
                SYNTAX Integer32
                UNITS "dB"
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular RSRQ (units: dB).
                    Remark:
                    If the value equals -9999, means signal strength
                    not applicable in this cellular."
                ::= { cellularSignalInfoEntry 8 }

            cellularNetworkType OBJECT-TYPE
                SYNTAX OCTET STRING
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular Network Type."
                ::= { cellularSignalInfoEntry 9 }

            cellularBand OBJECT-TYPE
                SYNTAX OCTET STRING
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular Band."
                ::= { cellularSignalInfoEntry 10 }

            cellularLac OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular Location Area Code(LAC).
                    Remark:
                    If the value equals -1, means LAC not applicable in this cellular."
                ::= { cellularSignalInfoEntry 11 }

            cellularTac OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular Tracking Area Code(TAC).
                    Remark:
                    If the value equals -1, means TAC not applicable in this cellular."
                ::= { cellularSignalInfoEntry 12 }

            cellularENodeBId OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular eNodeB ID.
                    Remark:
                    If the value equals -1, means eNodeB ID not applicable in this cellular."
                ::= { cellularSignalInfoEntry 13 }

        cellularIdentityInfo OBJECT IDENTIFIER ::= { cellularMib 2 }

-- **********************************************************************
-- *  Table
-- **********************************************************************
	cellularIdentityInfoTable OBJECT-TYPE
            SYNTAX SEQUENCE OF CellularIdentityInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Cellular identity info table"
            ::= { cellularIdentityInfo 1 }

            cellularIdentityInfoEntry OBJECT-TYPE
            SYNTAX CellularIdentityInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An entry in the cellularIdentityInfoTable"
            INDEX { cellularIdentityInfoId }
            ::= { cellularIdentityInfoTable 1 }

            CellularIdentityInfoEntry ::=
            SEQUENCE {
		cellularIdentityInfoId
			Integer32,
           	cellularIdentityInfoImei
                	OCTET STRING
            }

            cellularIdentityInfoId OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular identity ID."
                ::= { cellularIdentityInfoEntry 1 }

            cellularIdentityInfoImei OBJECT-TYPE
                SYNTAX OCTET STRING
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Cellular IMEI."
                ::= { cellularIdentityInfoEntry 2 }
END