TRIPPLITE-12X DEFINITIONS ::= BEGIN IMPORTS TRAP-TYPE FROM RFC-1215 DisplayString, TruthValue, TimeStamp, TimeInterval, DateAndTime, AutonomousType, VariablePointer, RowStatus FROM SNMPv2-TC OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Gauge32, Integer32, IpAddress FROM SNMPv2-SMI PositiveInteger, NonNegativeInteger FROM UPS-MIB tripplite FROM TRIPPLITE; tlPowerAlert MODULE-IDENTITY LAST-UPDATED "201702281600Z" ORGANIZATION "Tripp Lite" CONTACT-INFO "Software Engineering Tripp Lite 1111 W. 35th St. Chicago, IL 60609" DESCRIPTION "This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software." REVISION "201702281600Z" "Corrected spelling errors" REVISION "201507290000Z" DESCRIPTION "Removed obsolete legacy PowerAlert 11 sections" REVISION "201410170930Z" DESCRIPTION "Added tlUpsAggregatePowerFactor" REVISION "201409181000Z" DESCRIPTION "Added additional tlUpsInputSource... elements" REVISION "201408060830Z" DESCRIPTION "Added additional elements to tlUpsOutputCircuitTable" REVISION "201405080830Z" DESCRIPTION "Added tlUpsInputSourceSelect" REVISION "201404091000Z" DESCRIPTION "Added missing well known alarms" REVISION "201310301300Z" DESCRIPTION "Consolidated and Released for PAL v12.06.006x" ::= { tripplite 90 } -------------------------------------------------------------------------- -- Enumerations -------------------------------------------------------------------------- tlEnumerations OBJECT IDENTIFIER ::= { tripplite 2 } tlOperatingSystems OBJECT IDENTIFIER ::= { tlEnumerations 1 } hpux9 OBJECT IDENTIFIER ::= { tlOperatingSystems 1 } sunos4 OBJECT IDENTIFIER ::= { tlOperatingSystems 2 } solaris OBJECT IDENTIFIER ::= { tlOperatingSystems 3 } osf OBJECT IDENTIFIER ::= { tlOperatingSystems 4 } ultrix OBJECT IDENTIFIER ::= { tlOperatingSystems 5 } hpux10 OBJECT IDENTIFIER ::= { tlOperatingSystems 6 } netbsd1 OBJECT IDENTIFIER ::= { tlOperatingSystems 7 } freebsd OBJECT IDENTIFIER ::= { tlOperatingSystems 8 } irix OBJECT IDENTIFIER ::= { tlOperatingSystems 9 } linux OBJECT IDENTIFIER ::= { tlOperatingSystems 10 } bsdi OBJECT IDENTIFIER ::= { tlOperatingSystems 11 } openbsd OBJECT IDENTIFIER ::= { tlOperatingSystems 12 } win32 OBJECT IDENTIFIER ::= { tlOperatingSystems 13 } hpux11 OBJECT IDENTIFIER ::= { tlOperatingSystems 14 } win9x OBJECT IDENTIFIER ::= { tlOperatingSystems 50 } winnt OBJECT IDENTIFIER ::= { tlOperatingSystems 51 } solspark OBJECT IDENTIFIER ::= { tlOperatingSystems 52 } solintel OBJECT IDENTIFIER ::= { tlOperatingSystems 53 } aix OBJECT IDENTIFIER ::= { tlOperatingSystems 54 } sco OBJECT IDENTIFIER ::= { tlOperatingSystems 55 } osx OBJECT IDENTIFIER ::= { tlOperatingSystems 56 } unknown OBJECT IDENTIFIER ::= { tlOperatingSystems 255 } -------------------------------------------------------------------------- -- Power Alert System Settings -------------------------------------------------------------------------- -- tlPowerAlert OBJECT IDENTIFIER ::= { tripplite 90 } tlPASystem OBJECT IDENTIFIER ::= { tlPowerAlert 1 } tlPAContacts OBJECT IDENTIFIER ::= { tlPASystem 1 } tlPAEmailContacts OBJECT IDENTIFIER ::= { tlPAContacts 1 } tlPANumberOfEmailContacts OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number email contacts currently defined." ::= { tlPAEmailContacts 1 } tlPAEmailContactsTable OBJECT-TYPE SYNTAX SEQUENCE OF TlPAEmailContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts." ::= { tlPAEmailContacts 2 } tlPAEmailContactEntry OBJECT-TYPE SYNTAX TlPAEmailContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing email contacts information." INDEX { tlPAEmailContactIndex } ::= { tlPAEmailContactsTable 1 } TlPAEmailContactEntry ::= SEQUENCE { tlPAEmailContactIndex PositiveInteger, tlPAEmailContactRowStatus RowStatus, tlPAEmailContactName DisplayString, tlPAEmailContactAddress DisplayString } tlPAEmailContactIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of the email contact." ::= { tlPAEmailContactEntry 1 } tlPAEmailContactRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The row status for the tlPAEmailContactTable row" ::= { tlPAEmailContactEntry 2 } tlPAEmailContactName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the email contact." ::= { tlPAEmailContactEntry 3 } tlPAEmailContactAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The address of the email contact." ::= { tlPAEmailContactEntry 4 } tlPASnmpContacts OBJECT IDENTIFIER ::= { tlPAContacts 2 } tlPANumberOfSnmpContacts OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number SNMP contacts currently defined." ::= { tlPASnmpContacts 1 } tlPASnmpContactsTable OBJECT-TYPE SYNTAX SEQUENCE OF TlPASnmpContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts." ::= { tlPASnmpContacts 2 } tlPASnmpContactEntry OBJECT-TYPE SYNTAX TlPASnmpContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing SNMP contacts information." INDEX { tlPASnmpContactIndex } ::= { tlPASnmpContactsTable 1 } TlPASnmpContactEntry ::= SEQUENCE { tlPASnmpContactIndex PositiveInteger, tlPASnmpContactRowStatus RowStatus, tlPASnmpContactName DisplayString, tlPASnmpContactIpAddress DisplayString, tlPASnmpContactPort PositiveInteger, tlPASnmpContactSnmpVersion INTEGER, tlPASnmpContactSecurityName DisplayString, tlPASnmpContactPrivPassword DisplayString, tlPASnmpContactAuthPassword DisplayString } tlPASnmpContactIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this SNMP contact." ::= { tlPASnmpContactEntry 1 } tlPASnmpContactRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The row status for the tlPASnmpContactTable row" ::= { tlPASnmpContactEntry 2 } tlPASnmpContactName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the SNMP contact." ::= { tlPASnmpContactEntry 3 } tlPASnmpContactIpAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the SNMP contact." ::= { tlPASnmpContactEntry 4 } tlPASnmpContactPort OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-write STATUS current DESCRIPTION "The port of the SNMP contact." ::= { tlPASnmpContactEntry 5 } tlPASnmpContactSnmpVersion OBJECT-TYPE SYNTAX INTEGER { snmpv1(1), snmpv2c(2), snmpv3(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP contact version to use for sending traps." ::= { tlPASnmpContactEntry 6 } tlPASnmpContactSecurityName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP contact security name." ::= { tlPASnmpContactEntry 7 } tlPASnmpContactPrivPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP contact priv password to use for sending V3 traps." ::= { tlPASnmpContactEntry 8 } tlPASnmpContactAuthPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP contact auth password to use for sending V3 traps." ::= { tlPASnmpContactEntry 9 } -------------------------------------------------------------------------- -- UPS Device -------------------------------------------------------------------------- tlUPS OBJECT IDENTIFIER ::= { tripplite 100 } tlUpsObjects OBJECT IDENTIFIER ::= { tlUPS 1 } tlUpsIdent OBJECT IDENTIFIER ::= { tlUpsObjects 1 } tlUpsIdentUpsSoftwareChecksum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A checksum for the UPS software." ::= { tlUpsIdent 1 } tlUpsIdentSerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the UPS." ::= { tlUpsIdent 2 } tlUpsIdentID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A user-supplied ID for the UPS." ::= { tlUpsIdent 3 } tlUpsSnmpCardSerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the UPS." ::= { tlUpsIdent 4 } tlUpsSelectedDeviceID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for it" ::= { tlUpsIdent 5 } tlUpsLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The device location string." ::= { tlUpsIdent 6 } tlUpsBattery OBJECT IDENTIFIER ::= { tlUpsObjects 2 } tlUpsBatteryAge OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The age of the battery in years. This is equal to the current date minus tlConfigBattReplDate." ::= { tlUpsBattery 1 } tlUpsTemperatureF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees." ::= { tlUpsBattery 2 } tlUpsExternalBatteryAge OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The age of external battery in years. This is equal to the current date minus tlConfigExternalBattReplDate." ::= { tlUpsBattery 3 } tlUpsInput OBJECT IDENTIFIER ::= { tlUpsObjects 3 } tlUpsInputNumVoltages OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table." ::= { tlUpsInput 1 } tlUpsInputVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsInputVoltageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages." ::= { tlUpsInput 2 } tlUpsInputVoltageEntry OBJECT-TYPE SYNTAX TlUpsInputVoltageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular input voltage." INDEX { tlUpsInputVoltageIndex } ::= { tlUpsInputVoltageTable 1 } TlUpsInputVoltageEntry ::= SEQUENCE { tlUpsInputVoltageIndex PositiveInteger, tlUpsInputVoltageType NonNegativeInteger, tlUpsInputVoltage NonNegativeInteger } tlUpsInputVoltageIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS current DESCRIPTION "The input voltage identifier." ::= { tlUpsInputVoltageEntry 1 } tlUpsInputVoltageType OBJECT-TYPE SYNTAX INTEGER { phaseToNeutral(0), phaseToPhase(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Whether voltage measured is phase to phase or phase to neutral." ::= { tlUpsInputVoltageEntry 2 } tlUpsInputVoltage OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input voltage. A value of 6553 indicates Unknown." ::= { tlUpsInputVoltageEntry 3 } tlUpsInputSourceSelect OBJECT-TYPE SYNTAX INTEGER { inputSourceA(0), inputSourceB(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(0) for devices with a single input source. Setting this value is supported only on selected models." ::= { tlUpsInput 3 } tlUpsPhaseImbalance OBJECT-TYPE SYNTAX INTEGER UNITS "Percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of imbalance of the 3 phases." ::= { tlUpsInput 4 } tlUpsInputSourceAvailability OBJECT-TYPE SYNTAX INTEGER { none(0), inputSourceA(1), inputSourceB(2), inputSourceAB(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available." ::= { tlUpsInput 5 } tlUpsInputSourceInUse OBJECT-TYPE SYNTAX INTEGER { inputSourceA(0), inputSourceB(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The determination as to which one of two AC input lines is in use." ::= { tlUpsInput 6 } tlUpsInputSourceTransitionCount OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment." ::= { tlUpsInput 7 } tlUpsOutput OBJECT IDENTIFIER ::= { tlUpsObjects 4 } tlUpsOutputPowerTotal OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The power capacity of the device." ::= { tlUpsOutput 5 } tlUpsOutputCircuits OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of output circuits. This variable indicates the number of rows in the output circuit table." ::= { tlUpsOutput 6 } tlUpsOutputCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutputCircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits." ::= { tlUpsOutput 7 } tlUpsOutputCircuitEntry OBJECT-TYPE SYNTAX TlUpsOutputCircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular output circuit." INDEX { tlUpsOutputCircuitIndex } ::= { tlUpsOutputCircuitTable 1 } TlUpsOutputCircuitEntry ::= SEQUENCE { tlUpsOutputCircuitIndex PositiveInteger, tlUpsOutputCircuitStatus INTEGER, tlUpsOutputCircuitLoadCurrent NonNegativeInteger, tlUpsOutputCircuitVoltage NonNegativeInteger, tlUpsOutputCircuitPower NonNegativeInteger, tlUpsOutputCircuitPowerFactor NonNegativeInteger } tlUpsOutputCircuitIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS current DESCRIPTION "The output circuit identifier." ::= { tlUpsOutputCircuitEntry 1 } tlUpsOutputCircuitStatus OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the breaker is open or closed." ::= { tlUpsOutputCircuitEntry 2 } tlUpsOutputCircuitLoadCurrent OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 Amperes" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown." ::= { tlUpsOutputCircuitEntry 3 } tlUpsOutputCircuitVoltage OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present circuit voltage in tenths of an volt." ::= { tlUpsOutputCircuitEntry 4 } tlUpsOutputCircuitPower OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present power in watts. tenths of an amp." ::= { tlUpsOutputCircuitEntry 5 } tlUpsOutputCircuitPowerFactor OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "Percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The power factor of all receptacles in a given circuit as a %." ::= { tlUpsOutputCircuitEntry 6 } tlUpsAggregatePowerFactor OBJECT-TYPE SYNTAX PositiveInteger UNITS "0.1 Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The aggregrate power factor of all phases." ::= { tlUpsOutput 8 } -- tlUpsBypass [unused] OBJECT IDENTIFIER ::= { tlUpsObjects 5 } tlUpsAlarm OBJECT IDENTIFIER ::= { tlUpsObjects 6 } tlUpsAlarmsPresent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The present number of active alarm conditions." ::= { tlUpsAlarm 1 } tlUpsAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of alarm table entries." ::= { tlUpsAlarm 2 } tlUpsAlarmEntry OBJECT-TYPE SYNTAX TlUpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular alarm." INDEX { tlUpsAlarmId } ::= { tlUpsAlarmTable 1 } TlUpsAlarmEntry ::= SEQUENCE { tlUpsAlarmId PositiveInteger, tlUpsAlarmDescr AutonomousType, tlUpsAlarmTime TimeStamp, tlUpsAlarmDetail DisplayString, tlUpsAlarmDeviceId PositiveInteger, tlUpsAlarmDeviceName DisplayString, tlUpsAlarmLocation DisplayString, tlUpsAlarmGroup INTEGER, tlUpsAlarmIp IpAddress, tlUpsAlarmMac DisplayString } tlUpsAlarmId OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for an alarm condition." ::= { tlUpsAlarmEntry 1 } tlUpsAlarmDescr OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the alarm condition." ::= { tlUpsAlarmEntry 2 } tlUpsAlarmTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the alarm condition was detected." ::= { tlUpsAlarmEntry 3 } tlUpsAlarmDetail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the alarm condition." ::= { tlUpsAlarmEntry 4 } tlUpsAlarmDeviceId OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "A numeric identifier for the device on which the alarm is active." ::= { tlUpsAlarmEntry 5 } tlUpsAlarmDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A string identifier for the device on which the alarm is active." ::= { tlUpsAlarmEntry 6 } tlUpsAlarmLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The location of the device on which the alarm is active." ::= { tlUpsAlarmEntry 7 } tlUpsAlarmGroup OBJECT-TYPE SYNTAX INTEGER { critical(1), warning(2), info(3), status(4), offline(5), custom(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The category/group of this alarm." ::= { tlUpsAlarmEntry 8 } tlUpsAlarmIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The originating IP address associated with this alarm." ::= { tlUpsAlarmEntry 9 } tlUpsAlarmMac OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The originating mac address associated with this alarm." ::= { tlUpsAlarmEntry 10 } tlUpsWellKnownAlarms OBJECT IDENTIFIER ::= { tlUpsAlarm 3 } tlUpsAlarmPrimaryPowerOutage OBJECT-IDENTITY STATUS current DESCRIPTION "The primary power source is not present." ::= { tlUpsWellKnownAlarms 1 } tlUpsAlarmSecondaryPowerOutage OBJECT-IDENTITY STATUS current DESCRIPTION "The secondary power source is not present." ::= { tlUpsWellKnownAlarms 2 } tlUpsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "The load level is above the designated threshold." ::= { tlUpsWellKnownAlarms 3 } tlUpsAlarmOutputCurrentChanged OBJECT-IDENTITY STATUS current DESCRIPTION "The output current changed from its last known value." ::= { tlUpsWellKnownAlarms 4 } tlUpsAlarmBatteryAgeAboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "One or more batteries have been determined to require replacement." ::= { tlUpsWellKnownAlarms 5 } tlUpsAlarmLoadOff OBJECT-IDENTITY STATUS current DESCRIPTION "The load is off." ::= { tlUpsWellKnownAlarms 6 } tlUpsAlarmUserDefined OBJECT-IDENTITY STATUS current DESCRIPTION "A user-defined event is in alarm." ::= { tlUpsWellKnownAlarms 7 } tlUpsAlarmBatteryBad OBJECT-IDENTITY STATUS current DESCRIPTION "One or more batteries have been determined to require replacement." ::= { tlUpsWellKnownAlarms 8 } tlUpsAlarmOnBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS is drawing power from the batteries." ::= { tlUpsWellKnownAlarms 9 } tlUpsAlarmLowBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The remaining battery run-time is less than or equal to upsConfigLowBattTime." ::= { tlUpsWellKnownAlarms 10 } tlUpsAlarmDepletedBattery OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS will be unable to sustain the present load when and if the utility power is lost." ::= { tlUpsWellKnownAlarms 11 } tlUpsAlarmTempBad OBJECT-IDENTITY STATUS current DESCRIPTION "A temperature is out of tolerance." ::= { tlUpsWellKnownAlarms 12 } tlUpsAlarmInputBad OBJECT-IDENTITY STATUS current DESCRIPTION "An input condition is out of tolerance." ::= { tlUpsWellKnownAlarms 13 } tlUpsAlarmOutputBad OBJECT-IDENTITY STATUS current DESCRIPTION "An output condition (other than OutputOverload) is out of tolerance." ::= { tlUpsWellKnownAlarms 14 } tlUpsAlarmOutputOverload OBJECT-IDENTITY STATUS current DESCRIPTION "The output load exceeds the UPS output capacity." ::= { tlUpsWellKnownAlarms 15 } tlUpsAlarmOnBypass OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is presently engaged on the UPS." ::= { tlUpsWellKnownAlarms 16 } tlUpsAlarmBypassBad OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is out of tolerance." ::= { tlUpsWellKnownAlarms 17 } tlUpsAlarmOutputOffAsRequested OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS has shutdown as requested, i.e., the output is off." ::= { tlUpsWellKnownAlarms 18 } tlUpsAlarmUpsOffAsRequested OBJECT-IDENTITY STATUS current DESCRIPTION "The entire UPS has shutdown as commanded." ::= { tlUpsWellKnownAlarms 19 } tlUpsAlarmChargerFailed OBJECT-IDENTITY STATUS current DESCRIPTION "An uncorrected problem has been detected within the UPS charger subsystem." ::= { tlUpsWellKnownAlarms 20 } tlUpsAlarmUpsOutputOff OBJECT-IDENTITY STATUS current DESCRIPTION "The output of the UPS is in the off state." ::= { tlUpsWellKnownAlarms 21 } tlUpsAlarmUpsSystemOff OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS system is in the off state." ::= { tlUpsWellKnownAlarms 22 } tlUpsAlarmFanFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fans in the UPS has been detected." ::= { tlUpsWellKnownAlarms 23 } tlUpsAlarmFuseFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fuses has been detected." ::= { tlUpsWellKnownAlarms 24 } tlUpsAlarmGeneralFault OBJECT-IDENTITY STATUS current DESCRIPTION "A general fault in the UPS has been detected." ::= { tlUpsWellKnownAlarms 25 } tlUpsAlarmDiagnosticTestFailed OBJECT-IDENTITY STATUS current DESCRIPTION "The result of the last diagnostic test indicates a failure." ::= { tlUpsWellKnownAlarms 26 } tlUpsAlarmCommunicationsLost OBJECT-IDENTITY STATUS current DESCRIPTION "A problem has been encountered in the communications between the agent and the UPS." ::= { tlUpsWellKnownAlarms 27 } tlUpsAlarmAwaitingPower OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS output is off and the UPS is awaiting the return of input power." ::= { tlUpsWellKnownAlarms 28 } tlUpsAlarmShutdownPending OBJECT-IDENTITY STATUS current DESCRIPTION "A upsShutdownAfterDelay countdown is underway." ::= { tlUpsWellKnownAlarms 29 } tlUpsAlarmShutdownImminent OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown." ::= { tlUpsWellKnownAlarms 30 } tlUpsAlarmTestInProgress OBJECT-IDENTITY STATUS current DESCRIPTION "A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY." ::= { tlUpsWellKnownAlarms 31 } tlUpsAlarmCircuitBreaker1Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #1 is open." ::= { tlUpsWellKnownAlarms 32 } tlUpsAlarmCircuitBreaker2Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #2 is open." ::= { tlUpsWellKnownAlarms 33 } tlUpsAlarmCircuitBreaker3Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #3 is open." ::= { tlUpsWellKnownAlarms 34 } tlUpsAlarmCircuitBreaker4Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #4 is open." ::= { tlUpsWellKnownAlarms 35 } tlUpsAlarmCircuitBreaker5Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #5 is open." ::= { tlUpsWellKnownAlarms 36 } tlUpsAlarmCircuitBreaker6Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #6 is open." ::= { tlUpsWellKnownAlarms 37 } tlUpsAlarmCircuitBreaker7Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #7 is open." ::= { tlUpsWellKnownAlarms 38 } tlUpsAlarmCircuitBreaker8Open OBJECT-IDENTITY STATUS current DESCRIPTION "Circuit breakers #8 is open." ::= { tlUpsWellKnownAlarms 39 } tlUpsAlarmCurrent1AboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "The output current on line 1 exceeds load limits." ::= { tlUpsWellKnownAlarms 40 } tlUpsAlarmCurrent2AboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "The output current on line 2 exceeds load limits." ::= { tlUpsWellKnownAlarms 41 } tlUpsAlarmCurrent3AboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "The output current on line 3 exceeds load limits." ::= { tlUpsWellKnownAlarms 42 } tlUpsAlarmRuntimeBelowWarningLevel OBJECT-IDENTITY STATUS current DESCRIPTION "The battery seconds remaining is below warning level." ::= { tlUpsWellKnownAlarms 43 } tlUpsAlarmBusStartVoltageLow OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter start up bus voltage is too low." ::= { tlUpsWellKnownAlarms 44 } tlUpsAlarmBusOverVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter bus voltage is too high." ::= { tlUpsWellKnownAlarms 45 } tlUpsAlarmBusUnderVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter bus voltage is too low." ::= { tlUpsWellKnownAlarms 46 } tlUpsAlarmBusVoltageUnbalanced OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter bus voltage is not balanced." ::= { tlUpsWellKnownAlarms 47 } tlUpsAlarmInverterSoftStartBad OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter bus voltage cannot reach desired voltage within a specified duration." ::= { tlUpsWellKnownAlarms 48 } tlUpsAlarmInverterOverVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter voltage is too high." ::= { tlUpsWellKnownAlarms 49 } tlUpsAlarmInverterUnderVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter voltage is too low." ::= { tlUpsWellKnownAlarms 50 } tlUpsAlarmInverterCircuitBad OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter output is shorted." ::= { tlUpsWellKnownAlarms 51 } tlUpsAlarmBatteryOverVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The battery voltage is too high." ::= { tlUpsWellKnownAlarms 52 } tlUpsAlarmBatteryUnderVoltage OBJECT-IDENTITY STATUS current DESCRIPTION "The battery voltage is too low." ::= { tlUpsWellKnownAlarms 53 } tlUpsAlarmSiteWiringFault OBJECT-IDENTITY STATUS current DESCRIPTION "The utility input wiring is faulty." ::= { tlUpsWellKnownAlarms 54 } tlUpsAlarmOverTemperatureProtection OBJECT-IDENTITY STATUS current DESCRIPTION "The over temperature protection is activated." ::= { tlUpsWellKnownAlarms 55 } tlUpsAlarmOverCharged OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS is over charged." ::= { tlUpsWellKnownAlarms 56 } tlUpsAlarmEPOActive OBJECT-IDENTITY STATUS current DESCRIPTION "The EPO is currently activate." ::= { tlUpsWellKnownAlarms 57 } tlUpsAlarmBypassFrequencyBad OBJECT-IDENTITY STATUS current DESCRIPTION "The bypass frequency is out of tolerance." ::= { tlUpsWellKnownAlarms 58 } tlUpsAlarmExternalSmartBatteryAgeAboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "One or more external smart batteries have been determined to require replacement." ::= { tlUpsWellKnownAlarms 59 } tlUpsAlarmExternalNonSmartBatteryAgeAboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "One or more external non-smart batteries have been determined to require replacement." ::= { tlUpsWellKnownAlarms 60 } tlUpsAlarmSmartBatteryCommLost OBJECT-IDENTITY STATUS current DESCRIPTION "Communications with the smart batteries was lost." ::= { tlUpsWellKnownAlarms 61 } tlUpsAlarmSourceAOutage OBJECT-IDENTITY STATUS current DESCRIPTION "Input power source A is not present." ::= { tlUpsWellKnownAlarms 62 } tlUpsAlarmSourceBOutage OBJECT-IDENTITY STATUS current DESCRIPTION "Input power source B is not present." ::= { tlUpsWellKnownAlarms 63 } tlUpsAlarmWatchdogReset OBJECT-IDENTITY STATUS current DESCRIPTION "The internal watchdog triggered a reset of the device." ::= { tlUpsWellKnownAlarms 64 } tlUpsAlarmDevName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The name of the device, tlDevName, corresponding to the device that is associated with this alarm." ::= { tlUpsAlarm 7 } tlUpsAlarmDevLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm." ::= { tlUpsAlarm 8 } tlUpsAlarmCategory OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The category, tlDevEvtCategory, of this alarm." ::= { tlUpsAlarm 9 } tlUpsTest OBJECT IDENTIFIER ::= { tlUpsObjects 7 } tlUpsTestDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date of the last self-test run on the ups, in the format YYYYMMDD." ::= { tlUpsTest 1 } tlUpsTestResultsDetail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Result of the last self-test run on the ups." ::= { tlUpsTest 2 } tlUpsControl OBJECT IDENTIFIER ::= { tlUpsObjects 8 } tlUpsWatchdogSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not this UPS supports a watchdog reboot." ::= { tlUpsControl 1 } tlUpsWatchdogSecsBeforeReboot OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature." ::= { tlUpsControl 2 } tlUpsWellKnownControls OBJECT IDENTIFIER ::= { tlUpsControl 3 } tlUpsControlSelfTest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Self Test" ::= { tlUpsWellKnownControls 1 } tlUpsControlRamp OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Ramp" ::= { tlUpsWellKnownControls 2 } tlUpsControlShed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Shed" ::= { tlUpsWellKnownControls 3 } tlUpsControlUpsOn OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to turn UPS on" ::= { tlUpsWellKnownControls 4 } tlUpsControlUpsOff OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to turn UPS off" ::= { tlUpsWellKnownControls 5 } tlUpsConfig OBJECT IDENTIFIER ::= { tlUpsObjects 9 } tlUpsConfigBattReplDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The date on which the battery was last replaced, in the format YYYYMMDD." ::= { tlUpsConfig 1 } -- Deprecated, interface no longer supported. -- -- tlUpsConfigTftpGetAddr OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty" -- ::= { tlUpsConfig 2 } -- -- tlUpsConfigTftpGetAcction OBJECT-TYPE -- SYNTAX INTEGER { -- get(1), -- getting(2), -- idle(3) } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "setting this entry to get(1) will start a down load from the specified address, during the download this entry -- will read getting(2), when finished, the card will reboot to the new ini supplied parms. At all other times this -- entry will read idle(3)" -- ::= { tlUpsConfig 3 } tlUpsConfigDisplayUnits OBJECT-TYPE SYNTAX INTEGER { english(0), metric(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects English or Metric display for all readings. This selection may not be available on all devices. Further, some devices may support this selection, but not via a software selector. In this latter case, selections must be performed on the device itself." ::= { tlUpsConfig 4 } tlUpsConfigExternalBattReplDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The date on which the external battery was last replaced, in the format YYYYMMDD." ::= { tlUpsConfig 5 } tlUpsOutlet OBJECT IDENTIFIER ::= { tlUpsObjects 10 } tlUpsOutletNumOutlets OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of available Outlets in this device." ::= { tlUpsOutlet 1 } tlUpsOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all device Outlets for all devices." ::= { tlUpsOutlet 2 } tlUpsOutletEntry OBJECT-TYPE SYNTAX TlUpsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Outlet information applicable to a particular device managed by this agent." INDEX { tlUpsOutletIndex } ::= { tlUpsOutletTable 1 } TlUpsOutletEntry ::= SEQUENCE { tlUpsOutletIndex PositiveInteger, tlUpsOutletState INTEGER, tlUpsOutletType Integer32, tlUpsOutletControl INTEGER, tlUpsOutletName DisplayString, tlUpsOutletRampAction INTEGER, tlUpsOutletRampDataType INTEGER, tlUpsOutletRampData Integer32, tlUpsOutletShedAction INTEGER, tlUpsOutletShedDataType INTEGER, tlUpsOutletShedData Integer32, tlUpsOutletGroupNdx Integer32, tlUpsOutletCurrent PositiveInteger, tlUpsOutletPower PositiveInteger } tlUpsOutletIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this Outlet for the device indicated by tlDeviceIndex." ::= { tlUpsOutletEntry 1 } tlUpsOutletState OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Outlet." ::= { tlUpsOutletEntry 2 } tlUpsOutletType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15 " ::= { tlUpsOutletEntry 3 } tlUpsOutletControl OBJECT-TYPE SYNTAX INTEGER { turnOff(1), turnOn(2), cycle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the state of the Outlet." ::= { tlUpsOutletEntry 4 } tlUpsOutletName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the devices attached to the output(s) of the device." ::= { tlUpsOutletEntry 5 } tlUpsOutletRampAction OBJECT-TYPE SYNTAX INTEGER { remainOff(0), turnOnAfterDelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ramp action to take on the Outlet." ::= { tlUpsOutletEntry 6 } tlUpsOutletRampDataType OBJECT-TYPE SYNTAX INTEGER { delayInSeconds(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of data associated with ramp action." ::= { tlUpsOutletEntry 7 } tlUpsOutletRampData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The data value associated with type of ramp data." ::= { tlUpsOutletEntry 8 } tlUpsOutletShedAction OBJECT-TYPE SYNTAX INTEGER { remainOn(0), turnOffAfterDelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The shed action to take on the Outlet." ::= { tlUpsOutletEntry 9 } tlUpsOutletShedDataType OBJECT-TYPE SYNTAX INTEGER { delayInSeconds(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of data associated with shed action." ::= { tlUpsOutletEntry 10 } tlUpsOutletShedData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The data value associated with type of shed data." ::= { tlUpsOutletEntry 11 } tlUpsOutletGroupNdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped." ::= { tlUpsOutletEntry 12 } tlUpsOutletCurrent OBJECT-TYPE SYNTAX PositiveInteger UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this outlet's current, represented as 0.1A." ::= { tlUpsOutletEntry 13 } tlUpsOutletPower OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this outlet's power in watts." ::= { tlUpsOutletEntry 14 } tlUpsOutletGroup OBJECT IDENTIFIER ::= { tlUpsObjects 11 } tlUpsOutletNumOutletGroups OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of available Outlet Groups in this device." ::= { tlUpsOutletGroup 1 } tlUpsOutletGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups." ::= { tlUpsOutletGroup 2 } tlUpsOutletGroupEntry OBJECT-TYPE SYNTAX TlUpsOutletGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing outlet group information applicable to a particular device managed by this agent" INDEX { tlUpsOutletGroupIndex } ::= { tlUpsOutletGroupTable 1 } TlUpsOutletGroupEntry ::= SEQUENCE { tlUpsOutletGroupIndex PositiveInteger, tlUpsOutletGroupRowStatus RowStatus, tlUpsOutletGroupName DisplayString, tlUpsOutletGroupDesc DisplayString, tlUpsOutletGroupState INTEGER, tlUpsOutletGroupControl INTEGER } tlUpsOutletGroupIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this load group for the device." ::= { tlUpsOutletGroupEntry 1 } tlUpsOutletGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Row status for the tlUpsOutletGroupTable" ::= { tlUpsOutletGroupEntry 2 } tlUpsOutletGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this outlet group." ::= { tlUpsOutletGroupEntry 3 } tlUpsOutletGroupDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A description for this outlet group." ::= { tlUpsOutletGroupEntry 4 } tlUpsOutletGroupState OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), on(2), mixed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the outlet group." ::= { tlUpsOutletGroupEntry 5 } tlUpsOutletGroupControl OBJECT-TYPE SYNTAX INTEGER { turnOff(1), turnOn(2), cycle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the state of every outlet associated with the group." ::= { tlUpsOutletGroupEntry 6 } tlUpsMainOutlet OBJECT IDENTIFIER ::= { tlUpsObjects 12 } tlUpsMainOutletState OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), on(2), mixed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the main output of the device." ::= { tlUpsMainOutlet 1 } tlUpsMainOutletControllable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this device has controllable outlets" ::= { tlUpsMainOutlet 2 } tlUpsMainOutletControl OBJECT-TYPE SYNTAX INTEGER { idle(0), turnOff(1), turnOn(2), cycle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the state of the main outlet of the device." ::= { tlUpsMainOutlet 3 } tlUpsEnvironment OBJECT IDENTIFIER ::= { tlUpsObjects 13 } tlUpsTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature. The measurement returned will either be in units of Celsius (C) or Fahrenheit (F) depending upon whether Metric or English was selected for the reading by tlUpsConfigDisplayUnits." ::= { tlUpsEnvironment 1 } --------------------------------------------------------------- -- UPS traps --------------------------------------------------------------- tlUpsTraps OBJECT IDENTIFIER ::= { tlUPS 2 } tlUpsTrapAlarmEntryAddedV1 TRAP-TYPE ENTERPRISE tlUpsTraps VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } DESCRIPTION "This trap is sent each time an alarm is inserted into to the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= 3 tlUpsTrapAlarmEntryAdded NOTIFICATION-TYPE OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } STATUS current DESCRIPTION "This trap is sent each time an alarm is inserted into to the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= { tlUpsTraps 3 } tlUpsTrapAlarmEntryRemovedV1 TRAP-TYPE ENTERPRISE tlUpsTraps VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } DESCRIPTION "This trap is sent each time an alarm is removed from the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= 4 tlUpsTrapAlarmEntryRemoved NOTIFICATION-TYPE OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } STATUS current DESCRIPTION "This trap is sent each time an alarm is removed from the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= { tlUpsTraps 4 } -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- begin new traps -------------------------------------------------------------------------- -------------------------------------------------------------------------- tlUpsTrapSystemStartup NOTIFICATION-TYPE STATUS current DESCRIPTION "Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) " ::= { tlUpsTraps 5 } tlUpsTrapSystemShutdown NOTIFICATION-TYPE STATUS current DESCRIPTION "Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) " ::= { tlUpsTraps 6 } -------------------------------------------------------------------------- -------------------------------------------------------------------------- --- end new traps -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- EnviroSense Device -------------------------------------------------------------------------- tlEnviroSense OBJECT IDENTIFIER ::= { tripplite 101 } tlEnvEnvironment OBJECT IDENTIFIER ::= { tlEnviroSense 1 } tlEnvTemperatureData OBJECT IDENTIFIER ::= { tlEnvEnvironment 1 } tlEnvTemperatureC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature (C)." ::= { tlEnvTemperatureData 1 } tlEnvTemperatureF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature (F)." ::= { tlEnvTemperatureData 2 } tlEnvTemperatureLowLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The lower alarm limit for ambient temperature (F)." ::= { tlEnvTemperatureData 3 } tlEnvTemperatureHighLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper alarm limit for ambient temperature (F)." ::= { tlEnvTemperatureData 4 } tlEnvTemperatureInAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not temperature is in alarm." ::= { tlEnvTemperatureData 5 } tlEnvHumidityData OBJECT IDENTIFIER ::= { tlEnvEnvironment 2 } tlEnvHumidity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient humidity (%)." ::= { tlEnvHumidityData 1 } tlEnvHumidityLowLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The lower alarm limit for ambient humidity (%)." ::= { tlEnvHumidityData 2 } tlEnvHumidityHighLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper alarm limit for ambient humidity (%)." ::= { tlEnvHumidityData 3 } tlEnvHumidityInAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not humidity is in alarm." ::= { tlEnvHumidityData 4 } tlEnvContacts OBJECT IDENTIFIER ::= { tlEnviroSense 2 } tlEnvContactTable OBJECT-TYPE SYNTAX SEQUENCE OF TlEnvContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of contacts." ::= { tlEnvContacts 1 } tlEnvContactEntry OBJECT-TYPE SYNTAX TlEnvContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular contact." INDEX { tlEnvContactIndex } ::= { tlEnvContactTable 1 } TlEnvContactEntry ::= SEQUENCE { tlEnvContactIndex PositiveInteger, tlEnvContactName DisplayString, tlEnvContactStatus INTEGER, tlEnvContactConfig INTEGER } tlEnvContactIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The table row index for the contact." ::= { tlEnvContactEntry 1 } tlEnvContactName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name or description of the contact." ::= { tlEnvContactEntry 2 } tlEnvContactStatus OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the contact." ::= { tlEnvContactEntry 3 } tlEnvContactConfig OBJECT-TYPE SYNTAX INTEGER { normallyOpen(0), normallyClosed(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configuration of the contact." ::= { tlEnvContactEntry 4 } -------------------------------------------------------------------------- -- KVM over IP Device -------------------------------------------------------------------------- -- this is a 3rd party MIB structure located at { tripplite 102 } -------------------------------------------------------------------------- -- SR Cooling Device -------------------------------------------------------------------------- tlCooling OBJECT IDENTIFIER ::= { tripplite 103 } tlCoolingEnvironment OBJECT IDENTIFIER ::= { tlCooling 1 } tlCoolingIdent OBJECT IDENTIFIER ::= { tlCoolingEnvironment 1 } tlCoolingModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The model name for the AC Unit." ::= { tlCoolingIdent 1} tlCoolingManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer of the AC Unit." ::= { tlCoolingIdent 2 } tlCoolingSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the AC unit." ::= { tlCoolingIdent 3 } tlCoolingFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The firmware version of the AC Unit." ::= { tlCoolingIdent 4 } tlCoolingHostSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware version of the AC unit." ::= { tlCoolingIdent 5 } tlCoolingName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined name for the AC Unit." ::= { tlCoolingIdent 6 } tlCoolingLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined location of the AC Unit." ::= { tlCoolingIdent 7 } tlCoolingStatus OBJECT IDENTIFIER ::= { tlCoolingEnvironment 2 } tlCoolingCondOutletTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The condenser outlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 1 } tlCoolingCondInletTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The condenser inlet air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 2 } tlCoolingRefrigerantTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 3 } tlCoolingEvapSurfaceTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The surface temperature of the evaporator in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 4} tlCoolingSuctionPressure OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits." ::= { tlCoolingStatus 5} tlCoolingDischargePressure OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits." ::= { tlCoolingStatus 6} tlCoolingEvapFanSpeed OBJECT-TYPE SYNTAX INTEGER { off(0), low(1), medLow(2), med (3), medHi (4), hi (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of the evaporator fan." ::= { tlCoolingStatus 7} tlCoolingCondFanSpeed OBJECT-TYPE SYNTAX INTEGER { off(0), low(1), hi (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of the condenser fan." ::= { tlCoolingStatus 8} tlCoolingCompFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The operating frequency of the compressor in tenths of Arms." ::= { tlCoolingStatus 9} tlCoolingEEVPercentage OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The opening percentage of the EEV." ::= { tlCoolingStatus 10} tlCoolingUnitCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The the total current draw of the unit in tenths of Arms." ::= { tlCoolingStatus 11} tlCoolingFanCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Thethe current draw of the Evaporator and Condenser fans in tents of Arms." ::= { tlCoolingStatus 12 } tlCoolingCompCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The operating current of the compressor in Arms." ::= { tlCoolingStatus 13} tlCoolingReturnAirTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The return air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 14 } tlCoolingSuctionTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the compressor suction line in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 15 } tlCoolingSupplyAirTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The supply air temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlCoolingDisplayUnits." ::= { tlCoolingStatus 16 } tlCoolingRunTimes OBJECT IDENTIFIER ::= { tlCoolingEnvironment 3 } tlCoolingAirFilterRunHours OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total hours the air filter has been under operation." ::= { tlCoolingRunTimes 1 } tlCoolingEvapFanRunDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total days the evaporator fan has been under operation." ::= { tlCoolingRunTimes 2 } tlCoolingCondFanRunDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total days the condenser fan has been under operation." ::= { tlCoolingRunTimes 3 } tlCoolingCompressorRunDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total days the compressor has been under operation." ::= { tlCoolingRunTimes 4 } tlCoolingCondPumpRunDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total days the condensate pump has been under operation." ::= { tlCoolingRunTimes 5 } tlCoolingAtomizerRunDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total days the atomizer has been under operation." ::= { tlCoolingRunTimes 6 } tlCoolingConfig OBJECT IDENTIFIER ::= { tlCoolingEnvironment 4 } tlCoolingOnOff OBJECT-TYPE SYNTAX INTEGER { turnOffUnit(0), turnOnUnit(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Turn the unit off or on." ::= { tlCoolingConfig 1 } tlCoolingSetPointTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The set point temperature the unit will control the temperature to in tenths of degrees in Celsius or Fahrenheit based upon tleCoolDisplayUnits." ::= { tlCoolingConfig 2 } tlCoolingAutoStart OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specified if the unit should start automatically on power up." ::= { tlCoolingConfig 3 } tlCoolingFanSpeedOverride OBJECT-TYPE SYNTAX INTEGER { autoFanSpeed(0), low(1), medLow(2), med(3), medHi(4), hi(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Speed of evaporator fan set by the user." ::= { tlCoolingConfig 4 } tlCoolingControlType OBJECT-TYPE SYNTAX INTEGER { returnAirTemp(0), remoteTemperature(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Which temperature to be used as a control point." ::= { tlCoolingConfig 5 } tlCoolingCurrentRemoteTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The external remote temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlCoolingDisplayUnits" ::= { tlCoolingConfig 6 } tlCoolingDisplayUnits OBJECT-TYPE SYNTAX INTEGER { metric(0), english(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects English or Metric display for all readings." ::= { tlCoolingConfig 7 } tlCoolingBeepOnKey OBJECT-TYPE SYNTAX INTEGER { noBeep(0), beepOn(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the display sounds a beep when a key is pressed." ::= { tlCoolingConfig 8 } tlCoolingOutputRelaySource OBJECT-TYPE SYNTAX INTEGER { disabled(0), allAlarmsAndWarnings(1), criticalAlarmsOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm level that causes the ouput relay to activate." ::= { tlCoolingConfig 9 } tlCoolingOffOnLeak OBJECT-TYPE SYNTAX INTEGER { turnOff(0), alarmOnly(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the unit should stop cooling when leak input is activated." ::= { tlCoolingConfig 10 } tlCoolingOffOnInputContact OBJECT-TYPE SYNTAX INTEGER { turnOff(0), alarmOnly(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the unit should stop cooling when input contact is activated." ::= { tlCoolingConfig 11 } tlCoolingInputContactType OBJECT-TYPE SYNTAX INTEGER { ncRelay(0), noRelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The input contact type." ::= { tlCoolingConfig 12 } tlCoolingOutputRelayDefault OBJECT-TYPE SYNTAX INTEGER { nc(0), no(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Type of contact to make when output relay is activated." ::= { tlCoolingConfig 13 } tlCoolingAirFilterInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of weeks before the air filter needs to be changed." ::= { tlCoolingConfig 14 } tlCoolingWaterLeakContactType OBJECT-TYPE SYNTAX INTEGER { noRelay(0), ncRelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The input contact type." ::= { tlCoolingConfig 15 } tlCoolingThresholds OBJECT IDENTIFIER ::= { tlCoolingEnvironment 5 } tlCoolingMaxAirFilterRunHours OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum interval for air filter run hours before warning is annunciated." ::= { tlCoolingThresholds 1 } tlCoolingEnableAirFilterAlarm OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded." ::= { tlCoolingThresholds 2 } tlCoolingMaxSupplyTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum allowed supply air temperature before firing an alarm." ::= { tlCoolingThresholds 3 } tlCoolingMinSupplyTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum allowed supply air temperature allowed before firing an alarm." ::= { tlCoolingThresholds 4 } tlCoolingTempDiffAlarm OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum allowed air temperature deviation from set allowed before firing an alarm." ::= { tlCoolingThresholds 5 } tlCoolingMaxReturnAirTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded." ::= { tlCoolingThresholds 6 } tlCoolingAlarm OBJECT IDENTIFIER ::= { tlCooling 6 } tlCoolingWellKnownAlarms OBJECT IDENTIFIER ::= { tlCoolingAlarm 3 } tlCoolingSupplyAirSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The supply air sensor is in fault." ::= { tlCoolingWellKnownAlarms 1 } tlCoolingReturnAirSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The return air sensor is in fault." ::= { tlCoolingWellKnownAlarms 2 } tlCoolingCondenserInletAirSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The condenser inlet air sensor is in fault." ::= { tlCoolingWellKnownAlarms 3 } tlCoolingCondenserOutletAirSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The condenser outlet air sensor is in fault." ::= { tlCoolingWellKnownAlarms 4 } tlCoolingSuctionTemperatureSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The suction temperature sensor is in fault." ::= { tlCoolingWellKnownAlarms 5 } tlCoolingEvaporatorTemperatureSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The evaporator temperature sensor is in fault." ::= { tlCoolingWellKnownAlarms 6 } tlCoolingAirFilterClogged OBJECT-IDENTITY STATUS current DESCRIPTION "The air filter is clogged." ::= { tlCoolingWellKnownAlarms 7 } tlCoolingAirFilterRunHoursViolation OBJECT-IDENTITY STATUS current DESCRIPTION "The air filter run hours was violated." ::= { tlCoolingWellKnownAlarms 8 } tlCoolingSuctionPressureSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The suction pressure sensor is in fault." ::= { tlCoolingWellKnownAlarms 9 } tlCoolingInverterCommunicationsFault OBJECT-IDENTITY STATUS current DESCRIPTION "The inverter communications is in fault." ::= { tlCoolingWellKnownAlarms 10 } tlCoolingRemoteShutdownViaInputContact OBJECT-IDENTITY STATUS current DESCRIPTION "A remote shutdown was triggerd by an input contact." ::= { tlCoolingWellKnownAlarms 11 } tlCoolingCondensatePumpFault OBJECT-IDENTITY STATUS current DESCRIPTION "The condensate pump is in fault." ::= { tlCoolingWellKnownAlarms 12 } tlCoolingLowRefrigerantStartupFault OBJECT-IDENTITY STATUS current DESCRIPTION "The low refrigerant startup is in fault." ::= { tlCoolingWellKnownAlarms 13 } tlCoolingCondenserFanFault OBJECT-IDENTITY STATUS current DESCRIPTION "The condenser fan is in fault." ::= { tlCoolingWellKnownAlarms 14 } tlCoolingCondenserFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The condenser has failed." ::= { tlCoolingWellKnownAlarms 15 } tlCoolingEvaporatorCoolingFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The evaporator cooling is in fault." ::= { tlCoolingWellKnownAlarms 16 } tlCoolingReturnAirTempHigh OBJECT-IDENTITY STATUS current DESCRIPTION "The return air temperature is high." ::= { tlCoolingWellKnownAlarms 17 } tlCoolingSupplyAirTempHigh OBJECT-IDENTITY STATUS current DESCRIPTION "The supply air temperature is high." ::= { tlCoolingWellKnownAlarms 18 } tlCoolingEvaporatorFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The evaporator has failed." ::= { tlCoolingWellKnownAlarms 19 } tlCoolingEvaporatorFreezeUp OBJECT-IDENTITY STATUS current DESCRIPTION "The evaporator is frozen." ::= { tlCoolingWellKnownAlarms 20 } tlCoolingDischargePressureHigh OBJECT-IDENTITY STATUS current DESCRIPTION "The discharge pressure is high." ::= { tlCoolingWellKnownAlarms 21 } tlCoolingPressureGaugeFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The pressure gauge has failed." ::= { tlCoolingWellKnownAlarms 22 } tlCoolingDischargePressurePersistentHigh OBJECT-IDENTITY STATUS current DESCRIPTION "The discharge pressure is persistently high." ::= { tlCoolingWellKnownAlarms 23 } tlCoolingSuctionPressureLowStartFailure OBJECT-IDENTITY STATUS current DESCRIPTION "Cannot start due to low suction pressure." ::= { tlCoolingWellKnownAlarms 24 } tlCoolingSuctionPressureLow OBJECT-IDENTITY STATUS current DESCRIPTION "The suction pressure is low." ::= { tlCoolingWellKnownAlarms 25 } tlCoolingSuctionPressurePersistentLow OBJECT-IDENTITY STATUS current DESCRIPTION "The suction pressure is persistently low." ::= { tlCoolingWellKnownAlarms 26 } tlCoolingStartupLinePressureImbalance OBJECT-IDENTITY STATUS current DESCRIPTION "The startup line pressure is in imbalance." ::= { tlCoolingWellKnownAlarms 27 } tlCoolingCompressorFailure OBJECT-IDENTITY STATUS current DESCRIPTION "The compressor has failed." ::= { tlCoolingWellKnownAlarms 28 } tlCoolingCurrentLimit OBJECT-IDENTITY STATUS current DESCRIPTION "The current is out of range." ::= { tlCoolingWellKnownAlarms 29 } tlCoolingWaterLeak OBJECT-IDENTITY STATUS current DESCRIPTION "Water is leaking." ::= { tlCoolingWellKnownAlarms 30 } tlCoolingFanUnderCurrent OBJECT-IDENTITY STATUS current DESCRIPTION "The fan is under current." ::= { tlCoolingWellKnownAlarms 31 } tlCoolingFanOverCurrent OBJECT-IDENTITY STATUS current DESCRIPTION "The fan is over current." ::= { tlCoolingWellKnownAlarms 32 } tlCoolingDischargePressureSensorFault OBJECT-IDENTITY STATUS current DESCRIPTION "The discharge pressure sensor is in fault." ::= { tlCoolingWellKnownAlarms 33 } tlCoolingWaterFull OBJECT-IDENTITY STATUS current DESCRIPTION "Water is Full." ::= { tlCoolingWellKnownAlarms 34 } tlCoolingAutoCoolingOn OBJECT-IDENTITY STATUS current DESCRIPTION "Automatic cooling was activated to lower the temperature below the remote set point." ::= { tlCoolingWellKnownAlarms 35 } tlCoolingPowerButtonPressed OBJECT-IDENTITY STATUS current DESCRIPTION "Power button was pressed on the front panel." ::= { tlCoolingWellKnownAlarms 36 } tlCoolingDisconnectedFromDevice OBJECT-IDENTITY STATUS current DESCRIPTION "The device communications is disconnected." ::= { tlCoolingWellKnownAlarms 37 } -------------------------------------------------------------------------- -- SRCOOLNET Device -------------------------------------------------------------------------- tlSrCoolNet OBJECT IDENTIFIER ::= { tripplite 104} tlSrCoolNetData OBJECT IDENTIFIER ::= { tlSrCoolNet 1 } tlSrCoolNetIdent OBJECT IDENTIFIER ::= { tlSrCoolNetData 1 } tlSrCoolNetModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The model name for the device attached to the SRCOOLNET." ::= { tlSrCoolNetIdent 1} tlSrCoolNetManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer of the AC Unit." ::= { tlSrCoolNetIdent 2 } tlSrCoolNetSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the SRCOOLNET device." ::= { tlSrCoolNetIdent 3 } tlSrCoolNetHostSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of the SRCOOLNET device." ::= { tlSrCoolNetIdent 4 } tlSrCoolNetName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined name for the AC Unit." ::= { tlSrCoolNetIdent 5 } tlSrCoolNetLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined location of the AC Unit." ::= { tlSrCoolNetIdent 6 } tlSrCoolNetStatus OBJECT IDENTIFIER ::= { tlSrCoolNetData 2 } tlSrCoolNetMode OBJECT-TYPE SYNTAX INTEGER { off (0), idle (1), cooling (2), unknown (3), dehumidifying (4), defrost (5), notconnected(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current mode of SRCOOLNET." ::= { tlSrCoolNetStatus 1} tlSrCoolNetFanSpeed OBJECT-TYPE SYNTAX INTEGER { off (0), low (1), med (2), hi (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of the fan." ::= { tlSrCoolNetStatus 2} tlSrCoolNetReturnAirTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The return air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlSrCoolNetDisplayUnits." ::= { tlSrCoolNetStatus 3 } tlSrCoolNetWaterFull OBJECT-TYPE SYNTAX INTEGER { waterNotFull(0), waterFull(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the water reservoir is full or not full." ::= { tlSrCoolNetStatus 4 } tlSrCoolNetCurrentRemoteTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The EnviroSense temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlSrCoolNetDisplayUnits. Only available if EnviroSense is connected to SRCOOLNET." ::= { tlSrCoolNetStatus 5 } tlSrCoolNetDisplayUnits OBJECT-TYPE SYNTAX INTEGER { metric(0), english(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selects English or Metric display for all readings. AC unit must be manually configured to match this setting." ::= { tlSrCoolNetStatus 6 } tlSrCoolNetConfig OBJECT IDENTIFIER ::= { tlSrCoolNetData 3 } tlSrCoolNetOnOff OBJECT-TYPE SYNTAX INTEGER { turnOffUnit(0), turnOnUnit (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Turn the unit off or on." ::= { tlSrCoolNetConfig 1 } tlSrCoolSetMode OBJECT-TYPE SYNTAX INTEGER { cooling(0), dehumidifying (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the operating mode of cooling unit. Unit must be ON to set mode." ::= { tlSrCoolNetConfig 2 } tlSrCoolNetSetPointTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The local set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits." ::= { tlSrCoolNetConfig 3 } tlSrCoolNetRemoteSetPointTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The remote set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits. Only available when EnviroSense is connected to SRCOOLNET." ::= { tlSrCoolNetConfig 4 } tlSrCoolNetFanSpeedSetting OBJECT-TYPE SYNTAX INTEGER { auto(0), low(1), med(2), high(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the fan speed of the AC unit." ::= { tlSrCoolNetConfig 5 } tlSrCoolNetRemoteSetpointEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use remote temperature setpoint for control point versus return air temp. Only available when EnviroSense is connected to SRCOOLNET." ::= { tlSrCoolNetConfig 6 } tlSrCoolNetFanAlwaysOn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Leave fans on when not cooling. Only available when EnviroSense is connected to SRCOOLNET." ::= { tlSrCoolNetConfig 7 } tlSrCoolNetAlarm OBJECT IDENTIFIER ::= { tlSrCoolNet 2 } tlSrCoolNetWellKnownAlarms OBJECT IDENTIFIER ::= { tlSrCoolNetAlarm 1 } tlSrCoolNetWaterFullAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "Water reservoir full." ::= { tlSrCoolNetWellKnownAlarms 1 } -------------------------------------------------------------------------- -- Conformance definitions -------------------------------------------------------------------------- tlConformance OBJECT IDENTIFIER ::= { tripplite 20 } tlCompliances OBJECT IDENTIFIER ::= { tlConformance 1 } tlGroups OBJECT IDENTIFIER ::= { tlConformance 2 } tlSubsetGroups OBJECT IDENTIFIER ::= { tlGroups 1 } tlBasicGroups OBJECT IDENTIFIER ::= { tlGroups 2 } tlFullGroups OBJECT IDENTIFIER ::= { tlGroups 3 } tlUpsFullGroups OBJECT IDENTIFIER ::= { tlFullGroups 100 } tlUpsFullIdentGroup OBJECT-GROUP OBJECTS { tlUpsIdentUpsSoftwareChecksum, tlUpsIdentSerialNum, tlUpsIdentID, tlUpsSelectedDeviceID } STATUS current DESCRIPTION "The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 1 } tlUpsFullBatteryGroup OBJECT-GROUP OBJECTS { tlUpsBatteryAge, tlUpsTemperatureF } STATUS current DESCRIPTION "The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 2 } tlUpsFullAlarmGroup OBJECT IDENTIFIER ::= { tlUpsFullGroups 6 } tlUpsFullAlarmObjsGroup OBJECT-GROUP OBJECTS { tlUpsAlarmDevName, tlUpsAlarmDevLocation, tlUpsAlarmCategory } STATUS current DESCRIPTION "The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's" ::= { tlUpsFullAlarmGroup 1 } --tlUpsFullAlarmsGroup NOTIFICATION-GROUP -- NOTIFICATIONS { } -- STATUS current -- DESCRIPTION -- "The tlUpsFullAlarmGroup defines notifications which are -- common to the Alarm group of fully compliant Tripplite UPS's" -- ::= { tlUpsFullAlarmGroup 2 } tlUpsFullTestGroup OBJECT-GROUP OBJECTS { tlUpsTestDate, tlUpsTestResultsDetail } STATUS current DESCRIPTION "The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 7 } tlUpsFullControlGroup OBJECT-GROUP OBJECTS { tlUpsWatchdogSupported, tlUpsWatchdogSecsBeforeReboot } STATUS current DESCRIPTION "The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 8 } tlUpsFullConfigGroup OBJECT-GROUP OBJECTS { tlUpsConfigBattReplDate } STATUS current DESCRIPTION "The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 9 } tlUpsFullOutletGroup OBJECT-GROUP OBJECTS { tlUpsOutletNumOutlets } STATUS current DESCRIPTION "The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 10 } END