NETGEAR-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN -- Copyright Netgear Inc (2003-2015) All rights reserved. -- This SNMP Management Information Specification -- embodies Netgear Inc's confidential and proprietary -- intellectual property. Netgear Inc retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Netgear Inc -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC lb6m FROM QUANTA-LB6M-REF-MIB DisplayString FROM RFC1213-MIB pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB; fastPathpowerEthernetMIB MODULE-IDENTITY LAST-UPDATED "201503130000Z" -- 13 Mar 2015 12:00:00 GMT ORGANIZATION "Netgear Inc" CONTACT-INFO "" DESCRIPTION "This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet Interfaces and Hub MIB Working Group for managing Power Source Equipment (PSE). The objects in this MIB are intended to provide additional objects for reporting information available to the hardware on this platform which are not represented in the draft MIB." -- Revision history. REVISION "201503130000Z" -- 13 Mar 2015 12:00:00 GMT DESCRIPTION "agentPethPsePowerManagementMode object description is updated." REVISION "201404160000Z" -- 16 Apr 2014 12:00:00 GMT DESCRIPTION "Upoe support added in new object agentPethHighPowerMode." REVISION "201101260000Z" -- 26 Jan 2011 12:00:00 GMT DESCRIPTION "Postal address updated." REVISION "200708191200Z" -- 17 Aug 2007 12:00:00 GMT DESCRIPTION "PoE support for BCM59101 added." REVISION "200705230000Z" -- 23 May 2007 12:00:00 GMT DESCRIPTION "Netgear branding related changes." REVISION "200311101200Z" -- 10 Nov 2003 12:00:00 GMT DESCRIPTION "Initial revision." ::= { lb6m 15 } agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 } agentPethPsePortTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of per-port information and configuration objects relating to the power status of each port." ::= { agentPethObjects 1 } agentPethPsePortEntry OBJECT-TYPE SYNTAX AgentPethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects providing additional power information and control parameters for the specified port." AUGMENTS { pethPsePortEntry } ::= { agentPethPsePortTable 1 } AgentPethPsePortEntry ::= SEQUENCE { agentPethPowerLimit Gauge32, agentPethOutputPower Gauge32, agentPethOutputCurrent Gauge32, agentPethOutputVolts Gauge32, agentPethTemperature Gauge32, agentPethPowerLimitType INTEGER, agentPethHighPowerEnable TruthValue, agentPethPowerDetectionType INTEGER, agentPethFaultStatus INTEGER, agentPethPortReset INTEGER, agentPethPowerLimitMin Gauge32, agentPethPowerLimitMax Gauge32 , agentPethHighPowerMode INTEGER } agentPethPowerLimit OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-write STATUS current DESCRIPTION "The configured maximum power this port can provide to an attached device measured in Milliwatts." ::= { agentPethPsePortEntry 1 } agentPethOutputPower OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The power this port is supplying to an attached device measured in Milliwatts." ::= { agentPethPsePortEntry 2 } agentPethOutputCurrent OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliamps" MAX-ACCESS read-only STATUS current DESCRIPTION "The current this port is supplying to an attached device measured in Milliamps." ::= { agentPethPsePortEntry 3 } agentPethOutputVolts OBJECT-TYPE SYNTAX Gauge32 UNITS "Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage this port is supplying to an attached device measured in Volts." ::= { agentPethPsePortEntry 4 } agentPethTemperature OBJECT-TYPE SYNTAX Gauge32 UNITS "DEGREES" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The temperature measured at this port of the PoE Controller. It is measured in degree celcius." ::= { agentPethPsePortEntry 5 } agentPethPowerLimitType OBJECT-TYPE SYNTAX INTEGER { dot3af(1), user(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the maximum power that a port can deliver. A value of dot3af(1) means that the port power limit is as per the dot3af class of the PD attached. A value of user(2) means that the port power limit is equal to the value specified by agentPethPowerLimit" REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" ::= { agentPethPsePortEntry 6 } agentPethHighPowerEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "true (1) The PSE port can deliver power up to 32Watts. false(2) The PSE port can deliver power up to 18Watts" REFERENCE "Broadcom 5910X programmers guide" ::= { agentPethPsePortEntry 7 } agentPethPowerDetectionType OBJECT-TYPE SYNTAX INTEGER { none(0), pre-ieee(1), ieee(2), auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes PD detection mechanism performed by the PSE port. A value of none(0) means no detection is done. A value of pre-ieee(1) means only legacy capacitive detection scheme is used. A value of ieee(2) means that IEEE 802.3af 4point detection scheme is used. A value of auto(3) means that IEEE 802.3af 4point detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. The value 'none' can not be forcibly set by the administrator." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" ::= { agentPethPsePortEntry 8 } agentPethFaultStatus OBJECT-TYPE SYNTAX INTEGER { none(0), mpsAbsent(1), short(2), overload(3), powerDenied(4), thermalShutdown(5), startupFailure(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the error description when the pse port is in fault status. A value of none(0) specifies that the pse port is not in any error state. A value of mpsAbsent(1) specifies that the pse port has detected and absence of main power supply. A value of short(2) specifies that the pse port has detected a short circuit condition. A value of overload(3) specifies that the pd connected to the pse port had tried to draw more power than permissible by the hardware. A value of powerDenied(4) specifies that the pse port has been denied power because of shortage of power or due to administrative action. A value of thermalShutdown(5) specifies that the thermal threshold has exceeded for the pse port. A value of startupFailure(6) as fault status indicates that the port does not have sufficient voltage." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3af" ::= { agentPethPsePortEntry 9 } agentPethPortReset OBJECT-TYPE SYNTAX INTEGER { none(0), reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value of reset(1) is used to move the pse port dot3af state to idle. A read on this object will always return the value none(0). The value none(0) can not be forcibly set by the administrtor." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3af" ::= { agentPethPsePortEntry 10 } agentPethPowerLimitMin OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum power this port can be configured to provide, measured in Milliwatts." ::= { agentPethPsePortEntry 11 } agentPethPowerLimitMax OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum power this port can be configured to provide, measured in Milliwatts." ::= { agentPethPsePortEntry 12 } agentPethHighPowerMode OBJECT-TYPE SYNTAX INTEGER { disable(0), legacy(1), pre-dot3at(2), dot3at(3), upoe(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The mode configured for a PSE port to deliver high power. 'disable' means that a port is powered in the IEEE 802.3af mode. 'legacy' means that a port is powered using high-inrush current. 'pre-dot3at' means that a port is powered in the IEEE 802.3af mode initially, switched to the high-power IEEE 802.3at mode before 75msec. 'dot3at' means that a port is powered in the IEEE 802.3at mode. 'upoe' means that a port is powered in IEEE 802.3at mode using spare pair and data pair simultaneously to deliver up to 60W power." ::= { agentPethPsePortEntry 13 } -- Main objects agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 } agentPethMainPseTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support these objects. Values of all read-write objects in this table are persistent at restart/reboot." ::= { agentPethMainPseObjects 1 } agentPethMainPseEntry OBJECT-TYPE SYNTAX AgentPethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the Main power of a PSE. " AUGMENTS { pethMainPseEntry } ::= { agentPethMainPseTable 1 } AgentPethMainPseEntry ::= SEQUENCE { agentPethMainPseLegacy TruthValue } agentPethMainPseLegacy OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Legacy device detection. The value true(1) means legacy devices are detected; the value false(2) means legacy devices are not detected." ::= { agentPethMainPseEntry 1 } agentPethPseTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of per-unit information and configuration objects relating to the power configurtion for the entire pse unit." ::= { agentPethObjects 3 } agentPethPseEntry OBJECT-TYPE SYNTAX AgentPethPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects providing additional power information and control parameters for the specified pse unit." AUGMENTS { pethMainPseEntry } ::= { agentPethPseTable 1 } AgentPethPseEntry ::= SEQUENCE { agentPethPsePowerManagementMode INTEGER , agentPethPseCardModel DisplayString, agentPethPseCardHost DisplayString, agentPethPseCardStatus INTEGER } agentPethPsePowerManagementMode OBJECT-TYPE SYNTAX INTEGER { none(0), dynamic(1), static(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the power management algorithm used by the pse to deliver power to the requesting PDsthat a pds. A value of dynamic(1) means that power consumption of each port is measured and calculated in real-time. A value of static(2) means that power allocated for each port depends on the type of power threshold configured on the port." REFERENCE "Broadcom 5910X programmers guide" ::= { agentPethPseEntry 1 } agentPethPseCardModel OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the PoE daughther card model at PSE side." ::= { agentPethPseEntry 3 } agentPethPseCardHost OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the board which hosts the PoE daughther card at PSE side." ::= { agentPethPseEntry 4 } agentPethPseCardStatus OBJECT-TYPE SYNTAX INTEGER { absent-or-failed(0), running(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Displays running status of the PoE daughther card at PSE side. The value absent-or-failed(0) means that the card is either not present or some error has occurred. The value running(1) means that card is present and working fine." ::= { agentPethPseEntry 5 } END