NETTRACK-E3METER-SNMP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC ; nettrack OBJECT IDENTIFIER ::= { enterprises 21695 } public OBJECT IDENTIFIER ::= { nettrack 1 } e3Mib MODULE-IDENTITY LAST-UPDATED "201810090000Z" ORGANIZATION "net-track GmbH" CONTACT-INFO "net-track GmbH Duensstrasse 1 3186 Duedingen Switzerland www.net-track.ch" DESCRIPTION "Management Information for E3METER IPM products www.e3meter.com" REVISION "201810090000Z" DESCRIPTION "Added RCM traps." REVISION "201810080000Z" DESCRIPTION "Added RCM-related stuff." REVISION "201604180000Z" DESCRIPTION "Added e3IpmAlarmTable." REVISION "201602030000Z" DESCRIPTION "Added traps." REVISION "201204120000Z" DESCRIPTION "Added import of TEXTUAL-CONVENTION." REVISION "201111020000Z" DESCRIPTION "Added channel type and channel groups." REVISION "201108190000Z" DESCRIPTION "Added e3IpmChannelName." REVISION "201101260000Z" DESCRIPTION "Corrected some syntax errors for very picky parsers." REVISION "201012060000Z" DESCRIPTION "Added sensor data." REVISION "201010200000Z" DESCRIPTION "Initial version of this MIB module." ::= { public 10 } e3Ipm OBJECT IDENTIFIER ::= { e3Mib 7 } -- =========================================================================== -- Textual conventions -- Watts ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Watts" SYNTAX INTEGER VoltAmpereReactives ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Volt-ampere reactives" SYNTAX Integer32 VoltAmperes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Volt-amperes" SYNTAX Integer32 WattHours ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Watt hours" SYNTAX Integer32 VoltAmpereReactiveHours ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Volt-ampere reactive hours" SYNTAX Integer32 VoltAmpereHours ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Volt-ampere hours" SYNTAX Integer32 MilliAmperes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Milli-amperes" SYNTAX Integer32 MilliVolts ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Milli-volts" SYNTAX Integer32 MilliHertz ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Milli-hertz" SYNTAX Integer32 DeciDegreesCelsius ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Deci-degrees celsius" SYNTAX Integer32 Permil ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Per mil" SYNTAX INTEGER -- =========================================================================== -- Agent information -- e3IpmInfo OBJECT IDENTIFIER ::= { e3Ipm 1 } e3IpmInfoSerial OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number." ::= { e3IpmInfo 1 } e3IpmInfoModel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Model number." ::= { e3IpmInfo 2 } e3IpmInfoHWVersion OBJECT-TYPE SYNTAX INTEGER { rev-a (0), rev-b (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision." ::= { e3IpmInfo 3 } e3IpmInfoFWVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Integer representation of the firmware revision (major.minor) represented as a 16 bit integer." ::= { e3IpmInfo 4 } e3IpmInfoMeters OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of power meters in this IPS." ::= { e3IpmInfo 5 } -- =========================================================================== -- IPM meters -- e3IpmMeterTable OBJECT-TYPE SYNTAX SEQUENCE OF E3IpmMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The e3IpmMeterTable holds information related to the powermeters of all IPS nodes." ::= { e3Ipm 2 } e3IpmMeterEntry OBJECT-TYPE SYNTAX E3IpmMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds the information related to one specific powermeter." INDEX { e3IpmMeter } ::= { e3IpmMeterTable 1 } E3IpmMeterEntry ::= SEQUENCE { e3IpmMeter Integer32, e3IpmEnergyP WattHours, e3IpmEnergyQ VoltAmpereReactiveHours, e3IpmEnergyS VoltAmpereHours, e3IpmPowerP Watts, e3IpmPowerQ VoltAmpereReactives, e3IpmPowerS VoltAmperes, e3IpmUrms MilliVolts, e3IpmIrms MilliAmperes, e3IpmFrequency MilliHertz, e3IpmChannelName OCTET STRING, e3IpmChannelType INTEGER } e3IpmMeter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the powermeter of this IPS." ::= { e3IpmMeterEntry 1 } e3IpmEnergyP OBJECT-TYPE SYNTAX WattHours UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Active energy in watt hours." ::= { e3IpmMeterEntry 2 } e3IpmEnergyQ OBJECT-TYPE SYNTAX VoltAmpereReactiveHours UNITS "varh" MAX-ACCESS read-only STATUS current DESCRIPTION "Reactive energy in volt-ampere reactives hours." ::= { e3IpmMeterEntry 3 } e3IpmEnergyS OBJECT-TYPE SYNTAX VoltAmpereHours UNITS "VAh" MAX-ACCESS read-only STATUS current DESCRIPTION "Apparent energy in volt-ampere hours." ::= { e3IpmMeterEntry 4 } e3IpmPowerP OBJECT-TYPE SYNTAX Watts UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Active power at a given instant." ::= { e3IpmMeterEntry 5 } e3IpmPowerQ OBJECT-TYPE SYNTAX VoltAmpereReactives UNITS "var" MAX-ACCESS read-only STATUS current DESCRIPTION "Reactive power at a given instant." ::= { e3IpmMeterEntry 6 } e3IpmPowerS OBJECT-TYPE SYNTAX VoltAmperes UNITS "VA" MAX-ACCESS read-only STATUS current DESCRIPTION "Apparent power at a given instant." ::= { e3IpmMeterEntry 7 } e3IpmUrms OBJECT-TYPE SYNTAX MilliVolts UNITS "mV" MAX-ACCESS read-only STATUS current DESCRIPTION "RMS voltage at a given instant." ::= { e3IpmMeterEntry 8 } e3IpmIrms OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "RMS current at a given instant." ::= { e3IpmMeterEntry 9 } e3IpmFrequency OBJECT-TYPE SYNTAX MilliHertz UNITS "mHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency measured a given instant." ::= { e3IpmMeterEntry 10 } e3IpmChannelName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel name." ::= { e3IpmMeterEntry 11 } e3IpmChannelType OBJECT-TYPE SYNTAX INTEGER { live-wire (0), neutral-wire (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Channel type: For neutral wire channels, only I_rms will contain meaningful values." ::= { e3IpmMeterEntry 12 } -- =========================================================================== -- IPM sensors -- e3IpmSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF E3IpmSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The e3IpmSensorTable holds information related to the sensor of this IPM." ::= { e3Ipm 3 } e3IpmSensorEntry OBJECT-TYPE SYNTAX E3IpmSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds the information related to one specific sensor." INDEX { e3IpmSensor } ::= { e3IpmSensorTable 1 } E3IpmSensorEntry ::= SEQUENCE { e3IpmSensor Integer32, e3IpmSensorType INTEGER, e3IpmSensorVersion OCTET STRING, e3IpmSensorTemperatureCelsius DeciDegreesCelsius, e3IpmSensorHumidity Permil } e3IpmSensor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor port number." ::= { e3IpmSensorEntry 1 } e3IpmSensorType OBJECT-TYPE SYNTAX INTEGER { none (0), temp (1), temp-humidity (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor type." ::= { e3IpmSensorEntry 2 } e3IpmSensorVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor version." ::= { e3IpmSensorEntry 3 } e3IpmSensorTemperatureCelsius OBJECT-TYPE SYNTAX DeciDegreesCelsius UNITS "deg-C/10" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature in tenth degrees." ::= { e3IpmSensorEntry 4 } e3IpmSensorHumidity OBJECT-TYPE SYNTAX Permil UNITS "/1000" MAX-ACCESS read-only STATUS current DESCRIPTION "Relative humidity in per mil." ::= { e3IpmSensorEntry 5 } -- =========================================================================== -- IPM predefined channel groups -- e3IpmPGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF E3IpmPGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The e3IpmPGroupTable holds information related to predefined channel groups." ::= { e3Ipm 4 } e3IpmPGroupEntry OBJECT-TYPE SYNTAX E3IpmPGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds the information related to one specific group." INDEX { e3IpmPGroup } ::= { e3IpmPGroupTable 1 } E3IpmPGroupEntry ::= SEQUENCE { e3IpmPGroup Integer32, e3IpmPGName OCTET STRING, e3IpmPGMembers Integer32, e3IpmPGEnergyP WattHours, e3IpmPGEnergyQ VoltAmpereReactiveHours, e3IpmPGEnergyS VoltAmpereHours, e3IpmPGPowerP Watts, e3IpmPGPowerQ VoltAmpereReactives, e3IpmPGPowerS VoltAmperes, e3IpmPGIrms MilliAmperes } e3IpmPGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Predefined channel group number." ::= { e3IpmPGroupEntry 1 } e3IpmPGName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group name." ::= { e3IpmPGroupEntry 2 } e3IpmPGMembers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A bit set specifying the channels which are members of this channel group. If bit 0 is set, this means that channel CH1 is member of this group. Bit 1 stands for CH2 and so on." ::= { e3IpmPGroupEntry 3 } e3IpmPGEnergyP OBJECT-TYPE SYNTAX WattHours UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group active energy in watt hours." ::= { e3IpmPGroupEntry 4 } e3IpmPGEnergyQ OBJECT-TYPE SYNTAX VoltAmpereReactiveHours UNITS "varh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group reactive energy in volt-ampere reactives hours." ::= { e3IpmPGroupEntry 5 } e3IpmPGEnergyS OBJECT-TYPE SYNTAX VoltAmpereHours UNITS "VAh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group apparent energy in volt-ampere hours." ::= { e3IpmPGroupEntry 6 } e3IpmPGPowerP OBJECT-TYPE SYNTAX Watts UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group active power at a given instant." ::= { e3IpmPGroupEntry 7 } e3IpmPGPowerQ OBJECT-TYPE SYNTAX VoltAmpereReactives UNITS "var" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group reactive power at a given instant." ::= { e3IpmPGroupEntry 8 } e3IpmPGPowerS OBJECT-TYPE SYNTAX VoltAmperes UNITS "VA" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group apparent power at a given instant." ::= { e3IpmPGroupEntry 9 } e3IpmPGIrms OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group RMS current at a given instant." ::= { e3IpmPGroupEntry 10 } -- =========================================================================== -- IPM user defined channel groups -- e3IpmUGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF E3IpmUGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The e3IpmUGroupTable holds information related to user defined channel groups." ::= { e3Ipm 5 } e3IpmUGroupEntry OBJECT-TYPE SYNTAX E3IpmUGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds the information related to one specific group." INDEX { e3IpmUGroup } ::= { e3IpmUGroupTable 1 } E3IpmUGroupEntry ::= SEQUENCE { e3IpmUGroup Integer32, e3IpmUGName OCTET STRING, e3IpmUGMembers Integer32, e3IpmUGEnergyP WattHours, e3IpmUGEnergyQ VoltAmpereReactiveHours, e3IpmUGEnergyS VoltAmpereHours, e3IpmUGPowerP Watts, e3IpmUGPowerQ VoltAmpereReactives, e3IpmUGPowerS VoltAmperes, e3IpmUGIrms MilliAmperes } e3IpmUGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "User defined channel group number." ::= { e3IpmUGroupEntry 1 } e3IpmUGName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group name." ::= { e3IpmUGroupEntry 2 } e3IpmUGMembers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A bit set specifying the channels which are members of this channel group. If bit 0 is set, this means that channel CH1 is member of this group. Bit 1 stands for CH2 and so on. If no members are configured, the group is inactive." ::= { e3IpmUGroupEntry 3 } e3IpmUGEnergyP OBJECT-TYPE SYNTAX WattHours UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group active energy in watt hours." ::= { e3IpmUGroupEntry 4 } e3IpmUGEnergyQ OBJECT-TYPE SYNTAX VoltAmpereReactiveHours UNITS "varh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group reactive energy in volt-ampere reactives hours." ::= { e3IpmUGroupEntry 5 } e3IpmUGEnergyS OBJECT-TYPE SYNTAX VoltAmpereHours UNITS "VAh" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group apparent energy in volt-ampere hours." ::= { e3IpmUGroupEntry 6 } e3IpmUGPowerP OBJECT-TYPE SYNTAX Watts UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group active power at a given instant." ::= { e3IpmUGroupEntry 7 } e3IpmUGPowerQ OBJECT-TYPE SYNTAX VoltAmpereReactives UNITS "var" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group reactive power at a given instant." ::= { e3IpmUGroupEntry 8 } e3IpmUGPowerS OBJECT-TYPE SYNTAX VoltAmperes UNITS "VA" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group apparent power at a given instant." ::= { e3IpmUGroupEntry 9 } e3IpmUGIrms OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Channel group RMS current at a given instant." ::= { e3IpmUGroupEntry 10 } -- =========================================================================== -- IPM Alarm Settings -- e3IpmAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF E3IpmAlarmTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds alarm settings." ::= { e3Ipm 6 } e3IpmAlarmTableEntry OBJECT-TYPE SYNTAX E3IpmAlarmTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holds alarm settings for one specific measured value." INDEX { e3IpmAlarmIndex } ::= { e3IpmAlarmTable 1 } E3IpmAlarmTableEntry ::= SEQUENCE { e3IpmAlarmIndex INTEGER, e3IpmAlarmState INTEGER, e3IpmAlarmCritLowSet TruthValue, e3IpmAlarmCritLow Integer32, e3IpmAlarmWarnLowSet TruthValue, e3IpmAlarmWarnLow Integer32, e3IpmAlarmWarnHighSet TruthValue, e3IpmAlarmWarnHigh Integer32, e3IpmAlarmCritHighSet TruthValue, e3IpmAlarmCritHigh Integer32 } e3IpmAlarmIndex OBJECT-TYPE SYNTAX INTEGER { current-l1 (0), current-l2 (1), current-l3 (2), current-n (3), temp-int (4), temp-ext1 (5), temp-ext2 (6), rh-ext1 (7), rh-ext2 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the alarm described by the current entry. There are alarms for the current of all phases, for the temperature and the relative humidity." ::= { e3IpmAlarmTableEntry 1 } e3IpmAlarmState OBJECT-TYPE SYNTAX INTEGER { critical-low (0), warn-low (1), normal (2), warn-high (3), critical-high (4), unknown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shows this alarm entries' state. If no alarm settings are defined, the state is unknown." ::= { e3IpmAlarmTableEntry 2 } e3IpmAlarmCritLowSet OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "True if a 'critical low' alarm level for the current entry is defined, false otherwise." ::= { e3IpmAlarmTableEntry 3 } e3IpmAlarmCritLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'critical low' alarm level for the current entry in hundredths of the relevant unit (i.e. amperes, degrees celsius and %RH). If no alarm level is configured, this reads 0." ::= { e3IpmAlarmTableEntry 4 } e3IpmAlarmWarnLowSet OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "True if a 'warn low' alarm level for the current entry is defined, false otherwise." ::= { e3IpmAlarmTableEntry 5 } e3IpmAlarmWarnLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'warn low' alarm level for the current entry in hundredths of the relevant unit (i.e. amperes, degrees celsius and %RH). If no alarm level is configured, this reads 0." ::= { e3IpmAlarmTableEntry 6 } e3IpmAlarmWarnHighSet OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "True if a 'warn high' alarm level for the current entry is defined, false otherwise." ::= { e3IpmAlarmTableEntry 7 } e3IpmAlarmWarnHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'warn high' alarm level for the current entry in hundredths of the relevant unit (i.e. amperes, degrees celsius and %RH). If no alarm level is configured, this reads 0." ::= { e3IpmAlarmTableEntry 8 } e3IpmAlarmCritHighSet OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "True if a 'critical high' alarm level for the current entry is defined, false otherwise." ::= { e3IpmAlarmTableEntry 9 } e3IpmAlarmCritHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'critical high' alarm level for the current entry in hundredths of the relevant unit (i.e. amperes, degrees celsius and %RH). If no alarm level is configured, this reads 0." ::= { e3IpmAlarmTableEntry 10 } -- =========================================================================== -- IPM RCM Data -- e3IpmRcmTable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Table holding all residual current monitoring (RCM) data of this IPS." ::= { e3Ipm 7 } e3IpmRcmTableEntry OBJECT-TYPE SYNTAX E3IpmRcmTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One entry in the RCM table." INDEX { e3IpmRcmChannel } ::= { e3IpmRcmTable 1 } E3IpmRcmTableEntry ::= SEQUENCE { e3IpmRcmChannel Integer32, e3IpmRcmAcLimit MilliAmperes, e3IpmRcmDcLimit MilliAmperes, e3IpmRcmStatus Integer32, e3IpmRcmAc MilliAmperes, e3IpmRcmDc MilliAmperes } e3IpmRcmChannel OBJECT-TYPE SYNTAX INTEGER { total(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "RCM channel: 0 (total) is the total of all phases in this IPS." ::= { e3IpmRcmTableEntry 1 } e3IpmRcmAcLimit OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The factory configured AC RCM limit. Any measurement higher than this limit is considered a critical problem." ::= { e3IpmRcmTableEntry 2 } e3IpmRcmDcLimit OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The factory configured DC RCM limit. Any measurement higher than this limit is considered a critical problem." ::= { e3IpmRcmTableEntry 3 } e3IpmRcmStatus OBJECT-TYPE SYNTAX INTEGER { unknown(0), valid(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the RcmAc/RcmDc data. If the residual current cannot be measured, 0 (unknown) is signalled here, otherwise 1 (valid)." ::= { e3IpmRcmTableEntry 4 } e3IpmRcmAc OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The latest AC RCM measurement." ::= { e3IpmRcmTableEntry 5 } e3IpmRcmDc OBJECT-TYPE SYNTAX MilliAmperes UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The latest DC RCM measurement." ::= { e3IpmRcmTableEntry 6 } -- =========================================================================== -- IPM Traps -- e3IpmTraps OBJECT IDENTIFIER ::= { e3Mib 8 } -- Current e3IpmCurrentCritLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms } STATUS current DESCRIPTION "The e3IpmCurrentCritLow is triggered when the current on the given channel is less than or equal to the configured critical low threshold." ::= { e3IpmTraps 1 } e3IpmCurrentWarnLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms } STATUS current DESCRIPTION "The e3IpmCurrentWarnLow is triggered when the current on the given channel is less than or equal to the configured warn low threshold." ::= { e3IpmTraps 2 } e3IpmCurrentNormal NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms } STATUS current DESCRIPTION "The e3IpmCurrentNormal is triggered when the current on the given channel is not outside any configured limits." ::= { e3IpmTraps 3 } e3IpmCurrentWarnHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms } STATUS current DESCRIPTION "The e3IpmCurrentWarnHigh is triggered when the current on the given channel is greater than or equal to the configured warn high threshold." ::= { e3IpmTraps 4 } e3IpmCurrentCritHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmMeter, e3IpmIrms } STATUS current DESCRIPTION "The e3IpmCurrentCritHigh is triggered when the current on the given channel is greater than or equal to the configured critical high threshold." ::= { e3IpmTraps 5 } -- Temperature e3IpmTempCritLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius } STATUS current DESCRIPTION "The e3IpmTempCritLow is triggered when the temperature on the given sensor is less than or equal to the configured critical low threshold." ::= { e3IpmTraps 6 } e3IpmTempWarnLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius } STATUS current DESCRIPTION "The e3IpmTempWarnLow is triggered when the temperature on the given sensor is less than or equal to the configured warn low threshold." ::= { e3IpmTraps 7 } e3IpmTempNormal NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius } STATUS current DESCRIPTION "The e3IpmTempNormal is triggered when the temperature on the given sensor is not outside any configured limits." ::= { e3IpmTraps 8 } e3IpmTempWarnHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius } STATUS current DESCRIPTION "The e3IpmTempWarnHigh is triggered when the temperature on the given sensor is greater than or equal to the configured warn high threshold." ::= { e3IpmTraps 9 } e3IpmTempCritHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorTemperatureCelsius } STATUS current DESCRIPTION "The e3IpmTempCritHigh is triggered when the temperature on the given sensor is greater than or equal to the configured critical high threshold." ::= { e3IpmTraps 10 } -- Relative Humidity e3IpmRHCritLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity } STATUS current DESCRIPTION "The e3IpmRHCritLow is triggered when the relative humidity on the given sensor is less than or equal to the configured critical low threshold." ::= { e3IpmTraps 11 } e3IpmRHWarnLow NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity } STATUS current DESCRIPTION "The e3IpmRHWarnLow is triggered when the relative humidity on the given sensor is less than or equal to the configured warn low threshold." ::= { e3IpmTraps 12 } e3IpmRHNormal NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity } STATUS current DESCRIPTION "The e3IpmRHNormal is triggered when the relative humidity on the given sensor is not outside any configured limits." ::= { e3IpmTraps 13 } e3IpmRHWarnHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity } STATUS current DESCRIPTION "The e3IpmRHWarnHigh is triggered when the relative humidity on the given sensor is greater than or equal to the configured warn high threshold." ::= { e3IpmTraps 14 } e3IpmRHCritHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmSensor, e3IpmSensorHumidity } STATUS current DESCRIPTION "The e3IpmRHCritHigh is triggered when the relative humidity on the given sensor is greater than or equal to the configured critical high threshold." ::= { e3IpmTraps 15 } -- RCM Alarms e3IpmRcmAcNormal NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmAc } STATUS current DESCRIPTION "The e3IpmRcmAcNormal is triggered when the AC part of the residual current falls below the factory-configured limit." ::= { e3IpmTraps 16 } e3IpmRcmAcCritHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmAc } STATUS current DESCRIPTION "The e3IpmRcmAcCritHigh is triggered when the AC part of the residual current is greater than the factory-configured limit." ::= { e3IpmTraps 17 } e3IpmRcmDcNormal NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmDc } STATUS current DESCRIPTION "The e3IpmRcmDcNormal is triggered when the DC part of the residual current falls below the factory-configured limit." ::= { e3IpmTraps 18 } e3IpmRcmDcCritHigh NOTIFICATION-TYPE OBJECTS { e3IpmInfoSerial, e3IpmRcmChannel, e3IpmRcmDc } STATUS current DESCRIPTION "The e3IpmRcmDcCritHigh is triggered when the DC part of the residual current is greater than the factory-configured limit." ::= { e3IpmTraps 19 } END