-- RPS S.p.A enterprise MIB definition -- Copyright (c) RPS S.p.A. -- Version: 1.0.1 by Michele Marcon -- Date: 07.06.2017 -- Title: RIELLOMTS-MIB -- MDU-MIB { iso org(3) dod(6) internet(1) private(4) -- enterprises(1) riello(5491) } -- ************************************************************************ -- ************************************************************************ RIELLOMTS-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 rielloMIB FROM RIELLO-MIB; mtsMIB OBJECT IDENTIFIER ::= { rielloMIB 12 } mtsIdent OBJECT IDENTIFIER ::= { mtsMIB 1 } mtsIdentManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the mts manufacturer." ::= { mtsIdent 1 } mtsIdentModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The mts Model designation." ::= { mtsIdent 2 } mtsIdentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The mts Software version." ::= { mtsIdent 3 } mtsIdentIOConfiguration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mts input/output configuration (1 for Mono/mono, 4 for Tri/tri)." ::= { mtsIdent 4 } mtsIdentType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mts type (5 for ATS, 6 for STS)." ::= { mtsIdent 5 } mtsIdentInputSockets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of mts input sockets." ::= { mtsIdent 6 } mtsIdentOutputSockets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of mts output sockets." ::= { mtsIdent 7 } mtsIdentNominalCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mts nominal current (A)." ::= { mtsIdent 8 } mtsIdentNominalVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mts nominal voltage (V)." ::= { mtsIdent 9 } mtsIdentNominalFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mts nominal frequency (0.1 Hz)." ::= { mtsIdent 10 } mtsStatus OBJECT IDENTIFIER ::= { mtsMIB 2 } mtsS1Frequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The frequency of source 1 (0.1 Hz)." ::= { mtsStatus 1 } mtsS1VoltageL1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 1, line 1 (V)." ::= { mtsStatus 2 } mtsS1VoltageL2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 1, line 2 (V)." ::= { mtsStatus 3 } mtsS1VoltageL3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 1, line 3 (V)." ::= { mtsStatus 4 } mtsS2Frequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The frequency of source 2 (0.1 Hz)." ::= { mtsStatus 5 } mtsS2VoltageL1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 2, line 1 (V)." ::= { mtsStatus 6 } mtsS2VoltageL2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 2, line 2 (V)." ::= { mtsStatus 7 } mtsS2VoltageL3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage of source 2, line 3 (V)." ::= { mtsStatus 8 } mtsPhaseDifference OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Phase difference between sources (degrees)." ::= { mtsStatus 9 } mtsLoadL1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load of line 1 (%)." ::= { mtsStatus 10 } mtsLoadL2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load of line 2 (%)." ::= { mtsStatus 11 } mtsLoadL3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load of line 3 (%)." ::= { mtsStatus 12 } mtsOutputCurrentL1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load current of line 1 (0.1 A)." ::= { mtsStatus 13 } mtsOutputCurrentL2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load current of line 2 (0.1 A)." ::= { mtsStatus 14 } mtsOutputCurrentL3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load current of line 3 (0.1 A)." ::= { mtsStatus 15 } mtsTemperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The temperature (degrees C)." ::= { mtsStatus 16 } mtsSoundOff OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= sound on, 0= sound off." ::= { mtsStatus 17 } mtsTestInProgress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= test in progress, 0= test not in progress." ::= { mtsStatus 18 } mtsAuxPower2fail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= fail, 0= not fail." ::= { mtsStatus 19 } mtsAuxPower1fail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= fail, 0= not fail." ::= { mtsStatus 20 } mtsSynchrobad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= bad, 0= not bad." ::= { mtsStatus 21 } mtsPreferredSource OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= S2, 0= S1." ::= { mtsStatus 22 } mtsTransferhinibit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= hinibit, 0= not hinibit." ::= { mtsStatus 23 } mtsNonSynchInibit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 24 } mtsSourceS2bad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= bad, 0= not bad." ::= { mtsStatus 25 } mtsSourceS1bad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= bad, 0= not bad." ::= { mtsStatus 26 } mtsOnSourceS2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 27 } mtsOnSourceS1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 28 } mtsLocked OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= locked, 0= not locked." ::= { mtsStatus 29 } mtsOutputSwitchOff OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 30 } mtsS2Blackout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= blackout, 0= no blackout." ::= { mtsStatus 31 } mtsS2PhaseseqNotok OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 32 } mtsS2VoltOutoftolerance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 33 } mtsS1SCRAlternateLoss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 34 } mtsS1InputSWOff OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 35 } mtsS1Frequencybad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= bad, 0= not bad." ::= { mtsStatus 36 } mtsS1Balancebad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 37 } mtsS1Blackout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 38 } mtsS1PhaseseqNotok OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 39 } mtsS1VoltOutoftolerance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 40 } mtsUserlogin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 41 } mtsAlarmTemperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 42 } mtsAlarmOverload OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 43 } mtsGeneralFailure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 44 } mtsS2InputMCCBtrip OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 45 } mtsS1InputMCCBtrip OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 46 } mtsServicelogin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 47 } mtsOutputSCRalternanceloss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 48 } mtsManBypassS2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 49 } mtsManBypassS1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 50 } mtsManTransferS2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 51 } mtsManTransferS1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 52 } mtsS2SCRalternanceloss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 53 } mtsS2InputSWoff OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 54 } mtsS2Frequencybad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 55 } mtsS2Balancebad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1= yes, 0= no." ::= { mtsStatus 56 } mtsTraps OBJECT IDENTIFIER ::= { mtsMIB 4 } mtsNormal TRAP-TYPE ENTERPRISE mtsTraps DESCRIPTION "This trap is sent when STS is on normal status" ::= 1 mtsAnomaly TRAP-TYPE ENTERPRISE mtsTraps DESCRIPTION "This trap is sent when STS is has some anomaly and is resent every minute" ::= 2 mtsFault TRAP-TYPE ENTERPRISE mtsTraps DESCRIPTION "This trap is sent when STS is has some fault and is resent every minute" ::= 3 mtsLock TRAP-TYPE ENTERPRISE mtsTraps DESCRIPTION "This trap is sent when STS is locked and is resent every minute" ::= 4 mtsManualBypassEnabled TRAP-TYPE ENTERPRISE mtsTraps DESCRIPTION "This trap is sent when STS is on manual bypass and is resent every minute" ::= 5 END