SAF-INTEGRAX-MIB DEFINITIONS ::= BEGIN -- Definitions for include by other SAF Tehnika mib modules IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64, TimeTicks FROM SNMPv2-SMI -- [RFC2578] pointToPoint FROM SAF-ENTERPRISE DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC DisplayString, PhysAddress FROM RFC1213-MIB safIntegra FROM SAF-INTEGRA-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF -- [RFC2580] IpAddress FROM SNMPv2-SMI -- [RFC2578] IANAifType FROM IANAifType-MIB; -- saf OBJECT IDENTIFIER ::= { enterprises 7571 } -- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 } -- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 } -- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 } integraX MODULE-IDENTITY LAST-UPDATED "202006260000Z" -- 26 jun 2020 ORGANIZATION "SAF Tehnika" CONTACT-INFO "SAF Tehnika technical support " DESCRIPTION "SAF Integra-X device management base" -- Revision history REVISION "202006260000Z" -- 26 jun 2020 DESCRIPTION "Added system services / firmware upgrade." REVISION "202005190000Z" -- 19 may 2020 DESCRIPTION "Added system services / reboot option." REVISION "202005080000Z" -- 08 may 2020 DESCRIPTION "ACM min/max modem modulation read-only support." REVISION "202001140000Z" -- 14 jan 2020 DESCRIPTION "Added LSP/Backup port status." REVISION "201911270000Z" -- 27 nov 2019 DESCRIPTION "Added system service sensors." REVISION "201906110000Z" -- 11 jun 2019 DESCRIPTION "Added device fan error status." REVISION "201904230000Z" -- 23 apr 2019 DESCRIPTION "Added device type, serial number and product code." REVISION "201903070000Z" -- 07 mar 2019 DESCRIPTION "Changed integraXifPortSpeed to integraXifPortHighSpeed, that will use Mbps instead of bps. Added modem performance counters separately to modem A and modem B." REVISION "201903060000Z" -- 06 mar 2019 DESCRIPTION "Added modem A and B specific performance counters" REVISION "201902170000Z" -- 17 feb 2019 DESCRIPTION "Public Release 1.0" ::= { safIntegra 10 } FixedDiv20 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Fixed point, two decimals" SYNTAX Integer32 FixedDiv10 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "Fixed point, two decimals" SYNTAX Integer32 integraXtimestamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Last data update time" ::= { integraX 1 } integraXradio OBJECT IDENTIFIER ::= { integraX 2 } --radio/radioA integraXradioA OBJECT IDENTIFIER ::= { integraXradio 1 } integraXradioAtxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Output power of radio transmitter" ::= { integraXradioA 1 } integraXradioAtxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of radio transmitter" ::= { integraXradioA 2 } integraXradioArxLevel OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Level of the received signal" ::= { integraXradioA 3 } integraXradioArxLevelState OBJECT-TYPE SYNTAX INTEGER { ok(1), low(2), high(3), error(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Received signal level state" ::= { integraXradioA 4 } integraXradioAside OBJECT-TYPE SYNTAX INTEGER { high(1), low(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Radio side: Low/High" ::= { integraXradioA 5 } integraXradioAtxMute OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of 'Tx mute' 1 - Tx is muted, 2 - Tx is not muted. 3 - Status information unavailable" ::= { integraXradioA 6 } integraXradioAtxMuteDuration OBJECT-TYPE SYNTAX Integer32(0..214748364) UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Time remaning for Tx to be muted in seconds. To turn mute on send number of seconds between 10 and MAX. To turn mute off send 0. GET will retrieve remaining duration for mute or 0 if Tx mute is turned off." ::= { integraXradioA 7 } integraXradioAduplexShift OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Utilized duplex shift in kHz" ::= { integraXradioA 8 } integraXradioArxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of radio receiver" ::= { integraXradioA 9 } integraXradioAtemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Radio module temperature" ::= { integraXradioA 10 } integraXradioApll OBJECT-TYPE SYNTAX INTEGER { error(1), ok(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "PLL state of local-oscillator generator" ::= { integraXradioA 11 } --Settable radio parameter range values integraXradioArangesTable OBJECT-TYPE SYNTAX SEQUENCE OF IntegraXradioArangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Network interface port status data." ::= { integraXradioA 12 } integraXradioArangeEntry OBJECT-TYPE SYNTAX IntegraXradioArangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing network physical port status info." INDEX { integraXradioArangeEntryIndex } ::= { integraXradioArangesTable 1 } IntegraXradioArangeEntry ::= SEQUENCE { integraXradioArangeEntryIndex Integer32, integraXradioArangeDescr DisplayString, integraXradioArangeTxPower Integer32, integraXradioArangeTxFrequency Integer32 } integraXradioArangeEntryIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each range entry. Starts with 1 and is equal to a number of all range parameters." ::= { integraXradioArangeEntry 1 } integraXradioArangeDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "'Minimal' and 'maximal' labels" ::= { integraXradioArangeEntry 2 } integraXradioArangeTxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Output power ranges for radio transmitter" ::= { integraXradioArangeEntry 3 } integraXradioArangeTxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency ranges for radio transmitter" ::= { integraXradioArangeEntry 4 } --radio/radioB integraXradioB OBJECT IDENTIFIER ::= { integraXradio 2 } integraXradioBtxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Output power of radio transmitter" ::= { integraXradioB 1 } integraXradioBtxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of radio transmitter" ::= { integraXradioB 2 } integraXradioBrxLevel OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Level of the received signal" ::= { integraXradioB 3 } integraXradioBrxLevelState OBJECT-TYPE SYNTAX INTEGER { ok(1), low(2), high(3), error(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Received signal level state" ::= { integraXradioB 4 } integraXradioBside OBJECT-TYPE SYNTAX INTEGER { high(1), low(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Radio side: Low/High" ::= { integraXradioB 5 } integraXradioBtxMute OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of 'Tx mute' 1 - Tx is muted, 2 - Tx is not muted. 3 - Status information unavailable" ::= { integraXradioB 6 } integraXradioBtxMuteDuration OBJECT-TYPE SYNTAX Integer32(0..214748364) UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Time remaning for Tx to be muted in seconds. To turn mute on send number of seconds between 10 and MAX. To turn mute off send 0. GET will retrieve remaining duration for mute or 0 if Tx mute is turned off." ::= { integraXradioB 7 } integraXradioBduplexShift OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Utilized duplex shift in kHz" ::= { integraXradioB 8 } integraXradioBrxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of radio receiver" ::= { integraXradioB 9 } integraXradioBtemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Radio module temperature" ::= { integraXradioB 10 } integraXradioBpll OBJECT-TYPE SYNTAX INTEGER { error(1), ok(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "PLL state of local-oscillator generator" ::= { integraXradioB 11 } --Settable radio parameter range values integraXradioBrangesTable OBJECT-TYPE SYNTAX SEQUENCE OF IntegraXradioBrangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Network interface port status data." ::= { integraXradioB 12 } integraXradioBrangeEntry OBJECT-TYPE SYNTAX IntegraXradioBrangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing network physical port status info." INDEX { integraXradioBrangeEntryIndex } ::= { integraXradioBrangesTable 1 } IntegraXradioBrangeEntry ::= SEQUENCE { integraXradioBrangeEntryIndex Integer32, integraXradioBrangeDescr DisplayString, integraXradioBrangeTxPower Integer32, integraXradioBrangeTxFrequency Integer32 } integraXradioBrangeEntryIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each range entry. Starts with 1 and is equal to a number of all range parameters." ::= { integraXradioBrangeEntry 1 } integraXradioBrangeDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "'Minimal' and 'maximal' labels" ::= { integraXradioBrangeEntry 2 } integraXradioBrangeTxPower OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Output power ranges for radio transmitter" ::= { integraXradioBrangeEntry 3 } integraXradioBrangeTxFrequency OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency ranges for radio transmitter" ::= { integraXradioBrangeEntry 4 } integraXmodem OBJECT IDENTIFIER ::= { integraX 3 } --modem/modemA integraXmodemA OBJECT IDENTIFIER ::= { integraXmodem 1 } integraXmodemAacquireStatus OBJECT-TYPE SYNTAX INTEGER { acquireInProgress(1), acquireLocked(2), acquireFailed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the current status of modem data acquire when queried modem status. For detailed info use modemAcquireLastStatusDetails." ::= { integraXmodemA 1 } integraXmodemAnormalizedMse OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)" ::= { integraXmodemA 2 } -- ldpcDecoderStress OBJECT-TYPE integraXmodemAfecLoad OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)" ::= { integraXmodemA 3 } --TODO: change to new parameter related to FEC load integraXmodemAxpdEst OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)" ::= { integraXmodemA 4 } integraXmodemAacquireLastStatusDetails OBJECT-TYPE SYNTAX INTEGER { acquireLocked(1), acquireSweep(4), acquireMSEerror(5), acquireBITerror(6), acquireStopped(12), acquireSMerror(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire" ::= { integraXmodemA 5 } integraXmodemAtemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem DSP temperature" ::= { integraXmodemA 6 } integraXmodemArxModulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current (actual) Rx Modulation" ::= { integraXmodemA 7 } integraXmodemAtxModulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current (actual) Tx Modulation" ::= { integraXmodemA 8 } integraXmodemArxCapacity OBJECT-TYPE SYNTAX Integer32 UNITS "kb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "Rx ethernet capacity in kilobits per second" ::= { integraXmodemA 9 } integraXmodemAtxCapacity OBJECT-TYPE SYNTAX Integer32 UNITS "kb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "Tx ethernet capacity in kilobits per second" ::= { integraXmodemA 10 } integraXmodemAacmEngine OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "ACM engine status" ::= { integraXmodemA 11 } integraXmodemAcarrierOffset OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem carrier offset" ::= { integraXmodemA 12 } --modem A performance counters integraXmodemAcountTime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance count time" ::= { integraXmodemA 13 } integraXmodemAerroredBlock OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored blocks" ::= { integraXmodemA 14 } integraXmodemAerroredSecond OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored seconds" ::= { integraXmodemA 15 } integraXmodemAseverelyErroredSecond OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance severely errored seconds" ::= { integraXmodemA 16 } integraXmodemAbackgroundBlockError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance background block errors" ::= { integraXmodemA 17 } integraXmodemAtotalBlockNumber OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance total block number" ::= { integraXmodemA 18 } integraXmodemAerroredSecondRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored second ratio" ::= { integraXmodemA 19 } integraXmodemAseverelyErroredSecondRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance severely errored second ratio" ::= { integraXmodemA 20 } integraXmodemAbackgroundBlockErrorRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance background block error ratio" ::= { integraXmodemA 21 } integraXmodemAuptime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance : uptime" ::= { integraXmodemA 22 } integraXmodemAunavailtime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance : unavailtime" ::= { integraXmodemA 23 } integraXmodemAfecLdpcBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load block counter" ::= { integraXmodemA 24 } integraXmodemAfecLdpcUncorrectedBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load uncorrected block counter" ::= { integraXmodemA 25 } integraXmodemAfecLdpcUncorrectedPercent OBJECT-TYPE SYNTAX Integer32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load uncorrected percent" ::= { integraXmodemA 26 } integraXmodemAfecRsBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load RS block counter" ::= { integraXmodemA 27 } integraXmodemAfecRsUncorrectedBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load RS uncorrected block counter" ::= { integraXmodemA 28 } integraXmodemAmodulationACMmin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimal modulation for ACM enabled profile" ::= { integraXmodemA 29 } integraXmodemAmodulationACMmax OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximal modulation for ACM enabled profile" ::= { integraXmodemA 30 } --modem/modemB integraXmodemB OBJECT IDENTIFIER ::= { integraXmodem 2 } integraXmodemBacquireStatus OBJECT-TYPE SYNTAX INTEGER { acquireInProgress(1), acquireLocked(2), acquireFailed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the current status of modem data acquire when queried modem status. For detailed info use modemAcquireLastStatusDetails." ::= { integraXmodemB 1 } integraXmodemBnormalizedMse OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)" ::= { integraXmodemB 2 } -- ldpcDecoderStress OBJECT-TYPE integraXmodemBfecLoad OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)" ::= { integraXmodemB 3 } integraXmodemBxpdEst OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)" ::= { integraXmodemB 4 } integraXmodemBacquireLastStatusDetails OBJECT-TYPE SYNTAX INTEGER { acquireLocked(1), acquireSweep(4), acquireMSEerror(5), acquireBITerror(6), acquireStopped(12), acquireSMerror(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire" ::= { integraXmodemB 5 } integraXmodemBtemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem DSP temperature" ::= { integraXmodemB 6 } integraXmodemBrxModulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current (actual) Rx Modulation" ::= { integraXmodemB 7 } integraXmodemBtxModulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current (actual) Tx Modulation" ::= { integraXmodemB 8 } integraXmodemBrxCapacity OBJECT-TYPE SYNTAX Integer32 UNITS "kb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "Rx ethernet capacity in kilobits per second" ::= { integraXmodemB 9 } integraXmodemBtxCapacity OBJECT-TYPE SYNTAX Integer32 UNITS "kb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "Tx ethernet capacity in kilobits per second" ::= { integraXmodemB 10 } integraXmodemBacmEngine OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "ACM engine status" ::= { integraXmodemB 11 } integraXmodemBcarrierOffset OBJECT-TYPE SYNTAX Integer32 UNITS "Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem carrier offset" ::= { integraXmodemB 12 } --modem B performance counters integraXmodemBcountTime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance count time" ::= { integraXmodemB 13 } integraXmodemBerroredBlock OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored blocks" ::= { integraXmodemB 14 } integraXmodemBerroredSecond OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored seconds" ::= { integraXmodemB 15 } integraXmodemBseverelyErroredSecond OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance severely errored seconds" ::= { integraXmodemB 16 } integraXmodemBbackgroundBlockError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance background block errors" ::= { integraXmodemB 17 } integraXmodemBtotalBlockNumber OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance total block number" ::= { integraXmodemB 18 } integraXmodemBerroredSecondRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance errored second ratio" ::= { integraXmodemB 19 } integraXmodemBseverelyErroredSecondRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance severely errored second ratio" ::= { integraXmodemB 20 } integraXmodemBbackgroundBlockErrorRatio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance background block error ratio" ::= { integraXmodemB 21 } integraXmodemBuptime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance : uptime" ::= { integraXmodemB 22 } integraXmodemBunavailtime OBJECT-TYPE SYNTAX Counter64 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem performance : unavailtime" ::= { integraXmodemB 23 } integraXmodemBfecLdpcBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load block counter" ::= { integraXmodemB 24 } integraXmodemBfecLdpcUncorrectedBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load uncorrected block counter" ::= { integraXmodemB 25 } integraXmodemBfecLdpcUncorrectedPercent OBJECT-TYPE SYNTAX Integer32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load uncorrected percent" ::= { integraXmodemB 26 } integraXmodemBfecRsBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load RS block counter" ::= { integraXmodemB 27 } integraXmodemBfecRsUncorrectedBlockCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Modem FEC load RS uncorrected block counter" ::= { integraXmodemB 28 } integraXmodemBmodulationACMmin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimal modulation for ACM enabled profile" ::= { integraXmodemB 29 } integraXmodemBmodulationACMmax OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximal modulation for ACM enabled profile" ::= { integraXmodemB 30 } --modem common integraXmodemBandwidth OBJECT-TYPE SYNTAX Integer32 UNITS "kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal bandwidth" ::= { integraXmodem 3 } integraXmodemModulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Modulation (preferred)" ::= { integraXmodem 4 } integraXsystem OBJECT IDENTIFIER ::= { integraX 4 } integraXsysCPUtemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "System CPU temperature" ::= { integraXsystem 2 } integraXsysLicenseExpire OBJECT-TYPE SYNTAX Gauge32 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "License expires after number of seconds. In the case of -1, check licenseGenStatus status" ::= { integraXsystem 3 } integraXsysLicenseGenStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), expired(2), unknown(3), unlimitedTime(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "License General status." ::= { integraXsystem 4 } integraXsysPSUvoltage OBJECT-TYPE SYNTAX Integer32 UNITS "mV" MAX-ACCESS read-only STATUS current DESCRIPTION "Power voltage in mV" ::= { integraXsystem 5 } integraXsysPSUcurrent OBJECT-TYPE SYNTAX Integer32 UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Power current in mA" ::= { integraXsystem 6 } integraXsysPSUpower OBJECT-TYPE SYNTAX Integer32 UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "Power consumption in mW" ::= { integraXsystem 7 } integraXsysBoardTemperature OBJECT-TYPE SYNTAX FixedDiv10 UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "System temperature" ::= { integraXsystem 8 } integraXsysFreeMemory OBJECT-TYPE SYNTAX FixedDiv10 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "System free memory" ::= { integraXsystem 9 } integraXsysCPUidle OBJECT-TYPE SYNTAX FixedDiv10 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "System CPU idle" ::= { integraXsystem 10 } integraXsysDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type name" ::= { integraXsystem 11 } integraXsysDeviceSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device serial number" ::= { integraXsystem 12 } integraXsysDeviceProductModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device product model code" ::= { integraXsystem 13 } integraXsysFanError OBJECT-TYPE SYNTAX BITS { no(0), fan1(1), fan2(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Device fan 1 and fan 2 error status" ::= { integraXsystem 14 } -- service sensors integraXsysSw1v0core OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V0_CORE" ::= { integraXsystem 15 } integraXsysSw1v0avdd OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V0_AVDD" ::= { integraXsystem 16 } integraXsysSw1v2a OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V2A" ::= { integraXsystem 17 } integraXsysSw1v5ddr OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V5_DDR" ::= { integraXsystem 18 } integraXsysSw1v8 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V8" ::= { integraXsystem 19 } integraXsysSw2v5 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_2V5" ::= { integraXsystem 20 } integraXsysSw3v3 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_3V3" ::= { integraXsystem 21 } integraXsysVttrefPs OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "VTTVREF_PS" ::= { integraXsystem 22 } integraXsysVttddrPs OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "VTTDDR_PS" ::= { integraXsystem 23 } integraXsysZq1v0 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "ZQ_1V0" ::= { integraXsystem 24 } integraXsysZq1v5 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "ZQ_1V5" ::= { integraXsystem 25 } integraXsysZq1v8 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "ZQ_1V8" ::= { integraXsystem 26 } integraXsysZq2v5 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "ZQ_2V5" ::= { integraXsystem 27 } integraXsysZq3v3 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "ZQ_3V3" ::= { integraXsystem 28 } integraXsys5v0d OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "5V0D" ::= { integraXsystem 29 } integraXsysSw1v2 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "SW_1V2" ::= { integraXsystem 30 } integraXsysMdmVddcAvs OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_VDDC_AVS" ::= { integraXsystem 31 } integraXsysMdm3v3 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_3V3" ::= { integraXsystem 32 } integraXsysMdm1v0aPm OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_1V0A_PM" ::= { integraXsystem 33 } integraXsysMdm1v0a OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_1V0A" ::= { integraXsystem 34 } integraXsysMdm1v8a OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_1V8A" ::= { integraXsystem 35 } integraXsysMdmDAC02v5a OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_DAC0_2V5A" ::= { integraXsystem 36 } integraXsysMdmDAC12v5 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_DAC1_2V5A" ::= { integraXsystem 37 } integraXsysMdmDAC22v5 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_DAC2_2V5A" ::= { integraXsystem 38 } integraXsysMdm1v8io OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_1V8_IO" ::= { integraXsystem 39 } integraXsysMdm3v3io OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_3V3_IO" ::= { integraXsystem 40 } integraXsys3v3Radio OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "3V3_RADIO" ::= { integraXsystem 41 } integraXsysMdm4v0 OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "MDM_4V0" ::= { integraXsystem 42 } integraXsys5v0nRadio OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "5V0N_RADIO" ::= { integraXsystem 43 } integraXsysCoreVddSns OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "CORE_VDD_SNS" ::= { integraXsystem 44 } integraXsys40v0RadioSns OBJECT-TYPE SYNTAX FixedDiv20 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "40V0_RADIO_SNS" ::= { integraXsystem 45 } integraXsysServices OBJECT IDENTIFIER ::= { integraXsystem 46 } integraXsysServicesReboot OBJECT-TYPE SYNTAX INTEGER { reboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object can only be set to 1. It initiates system reboot immediately." ::= { integraXsysServices 1 } integraXsysServicesFtpSwitch OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2), unknown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status and on/off switch for the FTP server" ::= { integraXsysServices 2 } integraXsysServicesFwCurrInfo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Currently running FW info. Same output as in RFC1213-MIB::sysDescr." ::= { integraXsysServices 3 } integraXsysServicesFwAvailView OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "List FW available for installation (uploaded)." ::= { integraXsysServices 4 } integraXsysServicesFwRemove OBJECT-TYPE SYNTAX INTEGER { candfw1(1), candfw2(2), candfw3(3), candfw4(4), candfw5(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remove available (uploaded) FW version. View FW versions in integraXsysServicesFwAvailView. Send number corresponding to info in integraXsysServicesFwAvailView." ::= { integraXsysServices 5 } integraXsysServicesFwRemoveAll OBJECT-TYPE SYNTAX INTEGER { removeAllCandfw(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remove all available (uploaded) FW versions." ::= { integraXsysServices 6 } integraXsysServicesFwUpload OBJECT-TYPE SYNTAX INTEGER { upload(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Upload FW (make available for installation). You need to upload a firmware to FTP ftp://anonymous@DEVICE_IP:/firmware/ first! You must have only 1 firmware in firmware folder for this option to work! This option only starts upload on the device and doesn't return success status for it. Usually you should wait some time while the device completes upload. SNMP won't response to quieries while upload is in progress. You may check integraXsysServicesFwAvailView to see if your FW is ready for install." ::= { integraXsysServices 7 } integraXsysServicesFwInst OBJECT-TYPE SYNTAX INTEGER { candfw1(1), candfw2(2), candfw3(3), candfw4(4), candfw5(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Install FW version. You need check integraXsysServicesFwAvailView to see FW versions ready for install. This option only starts installation on the device and doesn't return success status for it. Usually you should wait some time while the device completes installation. SNMP won't response to quieries while upload is in progress. If FW installation was successful, integraXsysServicesFwSwitchNext will show different FW bank value for the next boot." ::= { integraXsysServices 8 } integraXsysServicesFwSwitchRunning OBJECT-TYPE SYNTAX INTEGER { fw1(1), fw2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "FW running bank info. Use integraXsysServicesFwSwitchNext to view and switch FW bank for the next boot." ::= { integraXsysServices 9 } integraXsysServicesFwSwitchNext OBJECT-TYPE SYNTAX INTEGER { fw1(1), fw2(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "FW next boot bank info. Set request can change FW bank for the next boot. View running FW bank number in integraXsysServicesFwSwitchRunning." ::= { integraXsysServices 10 } -- Ethernet integraXethernet OBJECT IDENTIFIER ::= { integraX 5 } -- Port status integraXifStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IntegraXifPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Network interface port status data." ::= { integraXethernet 1 } integraXifPortEntry OBJECT-TYPE SYNTAX IntegraXifPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing network physical port status info." INDEX { integraXifPortStatIndex } ::= { integraXifStatusTable 1 } IntegraXifPortEntry ::= SEQUENCE { integraXifPortStatIndex Integer32, integraXifPortStatDescr DisplayString, integraXifPortType IANAifType, integraXifPortMtu Integer32, integraXifPortHighSpeed Gauge32, integraXifPortPhysAddress PhysAddress, integraXifPortAdminStatus INTEGER, integraXifPortOperStatus INTEGER, integraXifPortLastChange TimeTicks, integraXifPortAutoneg INTEGER, integraXifPortDuplex INTEGER, integraXifPortSyncEthActive INTEGER, integraXifPortSyncEthPrio Integer32, integraXifPortFlowControl INTEGER } integraXifPortStatIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1." ::= { integraXifPortEntry 1 } integraXifPortStatDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP and WAN is radio port." ::= { integraXifPortEntry 2 } integraXifPortType OBJECT-TYPE SYNTAX IANAifType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack." ::= { integraXifPortEntry 3 } integraXifPortMtu OBJECT-TYPE SYNTAX Integer32 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmission unit value in bytes." ::= { integraXifPortEntry 4 } integraXifPortHighSpeed OBJECT-TYPE SYNTAX Gauge32 UNITS "Mbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Link speed in 1 000 000 * bits per second." ::= { integraXifPortEntry 5 } integraXifPortPhysAddress OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length." ::= { integraXifPortEntry 6 } integraXifPortAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Desired state of network interfaces. Interfaces can be enabled(1), disabled(2), unknown(3) (no info received)." ::= { integraXifPortEntry 7 } integraXifPortOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Actual state of interfaces. Link can be up(1), down(2) or in unknown(3) state." ::= { integraXifPortEntry 8 } integraXifPortLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter value is always 0 at the moment." ::= { integraXifPortEntry 9 } integraXifPortAutoneg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Auto-negotiation status. Unknown means no info was received." ::= { integraXifPortEntry 10 } integraXifPortDuplex OBJECT-TYPE SYNTAX INTEGER { full(1), half(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Duplex status for the interface." ::= { integraXifPortEntry 11 } integraXifPortSyncEthActive OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Synchronous Ethernet status. Can be active(1) or inactive(0)." ::= { integraXifPortEntry 12 } integraXifPortSyncEthPrio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Synchronous Ethernet priority." ::= { integraXifPortEntry 13 } integraXifPortFlowControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flow control status." ::= { integraXifPortEntry 14 } -- Port statistics integraXifStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF IntegraXifPortStcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Network interface port statistics data." ::= { integraXethernet 2 } integraXifPortStcEntry OBJECT-TYPE SYNTAX IntegraXifPortStcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing network physical port statistics counter data." INDEX { integraXifPortStcIndex } ::= { integraXifStatisticsTable 1 } IntegraXifPortStcEntry ::= SEQUENCE { integraXifPortStcIndex Integer32, integraXifPortStcDescr DisplayString, integraXifTimePassed TimeTicks, integraXifIngressPackets Counter64, integraXifIngressBytes Counter64, integraXifEgressPackets Counter64, integraXifEgressBytes Counter64, integraXifEtherStatsMulticastPkts Counter64, integraXifEtherStatsBroadcastPkts Counter64, integraXifEtherStatsPkts64Octets Counter64, integraXifEtherStatsPkts65to127Octets Counter64, integraXifEtherStatsPkts128to255Octets Counter64, integraXifEtherStatsPkts256to511Octets Counter64, integraXifEtherStatsPkts512to1023Octets Counter64, integraXifEtherStatsPkts1024to1518Octets Counter64, integraXifEtherStatsOversizePkts Counter64, integraXifEtherRxOversizePkts Counter64, integraXifEtherTxOversizePkts Counter64, integraXifEtherStatsOctets Counter64, integraXifEtherStatsPkts Counter64, integraXifEtherStatsTXNoErrors Counter64, integraXifEtherStatsRXNoErrors Counter64, integraXifEtherStatsPkts1519to1522Octets Counter64, integraXifIfInOctets Counter64, integraXifIfOutOctets Counter64, integraXifDot1dTpPortInFrames Counter64, integraXifDot1dTpPortOutFrames Counter64, integraXifReceivedPkts64Octets Counter64, integraXifTransmittedPkts64Octets Counter64, integraXifReceivedPkts65to127Octets Counter64, integraXifTransmittedPkts65to127Octets Counter64, integraXifReceivedPkts128to255Octets Counter64, integraXifTransmittedPkts128to255Octets Counter64, integraXifReceivedPkts256to511Octets Counter64, integraXifTransmittedPkts256to511Octets Counter64, integraXifReceivedPkts512to1023Octets Counter64, integraXifTransmittedPkts512to1023Octets Counter64, integraXifReceivedPkts1024to1518Octets Counter64, integraXifTransmittedPkts1024to1518Octets Counter64, integraXifIfInBroadcastPkts Counter64, integraXifIfOutBroadcastPkts Counter64, integraXifIfInMulticastPkts Counter64, integraXifIfOutMulticastPkts Counter64, integraXifDot3InPauseFrames Counter64, integraXifDot3OutPauseFrames Counter64, integraXifEtherStatsUndersizePkts Counter64, integraXifEtherStatsFragments Counter64, integraXifEtherStatsCRCAlignErrors Counter64, integraXifEtherStatsJabbers Counter64, integraXifIngressBPS Integer32, integraXifIngressPPS Integer32, integraXifEgressBPS Integer32, integraXifEgressPPS Integer32, integraXifAllCoSQoutPackets Counter64, integraXifAllCoSQoutBytes Counter64, integraXifAllCoSQdroppedPackets Counter64, integraXifAllCoSQdroppedBytes Counter64, integraXifProcessedRxPackets Counter64, integraXifProcessedRxBytes Counter64 } integraXifPortStcIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1." ::= { integraXifPortStcEntry 1 } integraXifPortStcDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP, WAN is radio port and MNG is internal management interface." ::= { integraXifPortStcEntry 2 } integraXifTimePassed OBJECT-TYPE SYNTAX TimeTicks UNITS "s/100" MAX-ACCESS read-only STATUS current DESCRIPTION "Statistics collection time." ::= { integraXifPortStcEntry 3 } integraXifIngressPackets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Packets that ingress on the port." ::= { integraXifPortStcEntry 4 } integraXifIngressBytes OBJECT-TYPE SYNTAX Counter64 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "Bytes that ingress on the port." ::= { integraXifPortStcEntry 5 } integraXifEgressPackets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Packets that egress on the port." ::= { integraXifPortStcEntry 6 } integraXifEgressBytes OBJECT-TYPE SYNTAX Counter64 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "Bytes that egress on the port." ::= { integraXifPortStcEntry 7 } integraXifEtherStatsMulticastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets (both received and transmitted) that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address." ::= { integraXifPortStcEntry 8 } integraXifEtherStatsBroadcastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets (both received and transmitted) that were directed to the broadcast address. Note that this does not include multicast packets." ::= { integraXifPortStcEntry 9 } integraXifEtherStatsPkts64Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were 64 octets in length (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 10 } integraXifEtherStatsPkts65to127Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 11 } integraXifEtherStatsPkts128to255Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 12 } integraXifEtherStatsPkts256to511Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 13 } integraXifEtherStatsPkts512to1023Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 14 } integraXifEtherStatsPkts1024to1518Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 15 } integraXifEtherStatsOversizePkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets (both received and transmitted) that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed." ::= { integraXifPortStcEntry 16 } integraXifEtherRxOversizePkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed." ::= { integraXifPortStcEntry 17 } integraXifEtherTxOversizePkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets transmitted that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed." ::= { integraXifPortStcEntry 18 } integraXifEtherStatsOctets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of octets of data (including those in bad packets) both received and transmitted." ::= { integraXifPortStcEntry 19 } integraXifEtherStatsPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of packets (including bad packets) both received and transmitted." ::= { integraXifPortStcEntry 20 } integraXifEtherStatsTXNoErrors OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Number of packets that were transmitted without errors." ::= { integraXifPortStcEntry 21 } integraXifEtherStatsRXNoErrors OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Number of packets that were received without errors." ::= { integraXifPortStcEntry 22 } integraXifEtherStatsPkts1519to1522Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets) (both received and transmitted) that were between 1519 and 1522 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 23 } integraXifIfInOctets OBJECT-TYPE SYNTAX Counter64 UNITS "octet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of octets of data (including those in bad packets) that were received." ::= { integraXifPortStcEntry 24 } integraXifIfOutOctets OBJECT-TYPE SYNTAX Counter64 UNITS "octet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of octets of data (including those in bad packets) that were transmitted." ::= { integraXifPortStcEntry 25 } integraXifDot1dTpPortInFrames OBJECT-TYPE SYNTAX Counter64 UNITS "frame" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that have been received by this port from its segment." ::= { integraXifPortStcEntry 26 } integraXifDot1dTpPortOutFrames OBJECT-TYPE SYNTAX Counter64 UNITS "frame" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that have been transmitted by this port to its segment." ::= { integraXifPortStcEntry 27 } integraXifReceivedPkts64Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were 64 octets in length (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 28 } integraXifTransmittedPkts64Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were 64 octets in length (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 29 } integraXifReceivedPkts65to127Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 30 } integraXifTransmittedPkts65to127Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 31 } integraXifReceivedPkts128to255Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 32 } integraXifTransmittedPkts128to255Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 33 } integraXifReceivedPkts256to511Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 34 } integraXifTransmittedPkts256to511Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 35 } integraXifReceivedPkts512to1023Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 36 } integraXifTransmittedPkts512to1023Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 37 } integraXifReceivedPkts1024to1518Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of received packets that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 38 } integraXifTransmittedPkts1024to1518Octets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of transmitted packets that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets)." ::= { integraXifPortStcEntry 39 } integraXifIfInBroadcastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of received good packets that were directed to the broadcast address. Note that this does not include multicast packets." ::= { integraXifPortStcEntry 40 } integraXifIfOutBroadcastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted good packets that were directed to the broadcast address. Note that this does not include multicast packets." ::= { integraXifPortStcEntry 41 } integraXifIfInMulticastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of received good packets that were directed to a multicast address. Note that this number does not include broadcast packets." ::= { integraXifPortStcEntry 42 } integraXifIfOutMulticastPkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of transmitted good packets that were directed to a multicast address. Note that this number does not include broadcast packets." ::= { integraXifPortStcEntry 43 } integraXifDot3InPauseFrames OBJECT-TYPE SYNTAX Counter64 UNITS "frame" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MAC Control frames received on this interface with an opcode indicating the PAUSE operation. This counter does not increment when the interface is operating in half-duplex mode." ::= { integraXifPortStcEntry 44 } integraXifDot3OutPauseFrames OBJECT-TYPE SYNTAX Counter64 UNITS "frame" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MAC Control frames transmitted on this interface with an opcode indicating the PAUSE operation. This counter does not increment when the interface is operating in half-duplex mode." ::= { integraXifPortStcEntry 45 } integraXifEtherStatsUndersizePkts OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed." ::= { integraXifPortStcEntry 46 } integraXifEtherStatsFragments OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that it is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits." ::= { integraXifPortStcEntry 47 } integraXifEtherStatsCRCAlignErrors OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { integraXifPortStcEntry 48 } integraXifEtherStatsJabbers OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that this definition of jabber is different than the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These documents define jabber as the condition where any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms." ::= { integraXifPortStcEntry 49 } integraXifIngressBPS OBJECT-TYPE SYNTAX Integer32 UNITS "Bps" MAX-ACCESS read-only STATUS current DESCRIPTION "Ingoing data transfer rate in bytes per second." ::= { integraXifPortStcEntry 50 } integraXifIngressPPS OBJECT-TYPE SYNTAX Integer32 UNITS "pps" MAX-ACCESS read-only STATUS current DESCRIPTION "Ingoing data transfer rate in packets per second." ::= { integraXifPortStcEntry 51 } integraXifEgressBPS OBJECT-TYPE SYNTAX Integer32 UNITS "Bps" MAX-ACCESS read-only STATUS current DESCRIPTION "Outgoing data transfer rate in bytes per second." ::= { integraXifPortStcEntry 52 } integraXifEgressPPS OBJECT-TYPE SYNTAX Integer32 UNITS "pps" MAX-ACCESS read-only STATUS current DESCRIPTION "Outgoing data transfer rate in packets per second." ::= { integraXifPortStcEntry 53 } integraXifAllCoSQoutPackets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "All CoSQ outgoing packets." ::= { integraXifPortStcEntry 54 } integraXifAllCoSQoutBytes OBJECT-TYPE SYNTAX Counter64 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "All CoSQ outgoing bytes." ::= { integraXifPortStcEntry 55 } integraXifAllCoSQdroppedPackets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "All CoSQ dropped packets." ::= { integraXifPortStcEntry 56 } integraXifAllCoSQdroppedBytes OBJECT-TYPE SYNTAX Counter64 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "All CoSQ dropped bytes." ::= { integraXifPortStcEntry 57 } integraXifProcessedRxPackets OBJECT-TYPE SYNTAX Counter64 UNITS "packet" MAX-ACCESS read-only STATUS current DESCRIPTION "Processed received packets." ::= { integraXifPortStcEntry 58 } integraXifProcessedRxBytes OBJECT-TYPE SYNTAX Counter64 UNITS "B" MAX-ACCESS read-only STATUS current DESCRIPTION "Processed received bytes." ::= { integraXifPortStcEntry 59 } integraXifLspPortAdminState OBJECT-TYPE SYNTAX INTEGER { disabled(1), lsp(2), backup(3), unknown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "LSP port status." ::= { integraXethernet 3 } integraXifLspPortList OBJECT-TYPE SYNTAX BITS { none(0), lan1(1), lan2(2), lan3(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "LSP port status." ::= { integraXethernet 4 } integraXifLspPortStatus OBJECT-TYPE SYNTAX INTEGER { lspPortOK(1), lspPortDownBlockedByLSP(2), backupNoLink(3), backupLinkActive(4), backupLinkReady(5), unknown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "LSP port status." ::= { integraXethernet 5 } -- Configuration applying/saving objects integraXexecuteConfig OBJECT-TYPE SYNTAX INTEGER { execute(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower" ::= { integraX 6 } integraXneedStore OBJECT-TYPE SYNTAX INTEGER { no(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object shows if there is unsaved, but executed (running) configuration. Unsaved changes will be lost after device reboot. Unsaved entities are shown bit wise, starting from LSB as follows: BIT0 Aggregation BIT1 Event log BIT2 Modem BIT3 Network BIT4 Performance BIT5 Radio BIT6 SNMP BIT7 Synchronous Ethernet BIT8 System" ::= { integraX 7 } integraXstoreConfig OBJECT-TYPE SYNTAX INTEGER { store(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object can only be set to 1. It initiates saving of running configuration. It will only work if there are unsaved, but executed (running) changes (configuration). Setting it when no new running configuration is available will do nothing and return an error." ::= { integraX 8 } -- IP settings integraXnetCfg OBJECT IDENTIFIER ::= { integraX 9 } integraXnetCfgIPaddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Local IP address" ::= { integraXnetCfg 1 } integraXnetCfgIPmask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Local IP mask" ::= { integraXnetCfg 2 } integraXnetCfgIPgateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IP gateway Send '0' or '255.255.255.255' to clear." ::= { integraXnetCfg 3 } integraXnetCfgRemoteIPaddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote IP address" ::= { integraXnetCfg 4 } -- Conformance integraXConformance OBJECT IDENTIFIER ::= { integraX 10 } integraXCompliances OBJECT IDENTIFIER ::= { integraXConformance 1 } integraXCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP engine which implements the SAF Tehnika Integra-X device." MODULE -- this module MANDATORY-GROUPS { integraXMiscGroup, integraXRadioGroup, integraXModemGroup, integraXSystemGroup, integraXEthernetGeneralGroup, integraXEthernetMiiPortGroup } ::= { integraXCompliances 1 } integraXGroups OBJECT IDENTIFIER ::= { integraXConformance 2 } integraXMiscGroup OBJECT-GROUP OBJECTS { integraXtimestamp } STATUS current DESCRIPTION "misc data" ::= { integraXGroups 1 } integraXRadioGroup OBJECT-GROUP OBJECTS { integraXradioAtxPower, integraXradioAtxFrequency, integraXradioArxLevel, integraXradioArxLevelState, integraXradioAside, integraXradioAtxMute, integraXradioAtxMuteDuration, integraXradioAduplexShift, integraXradioArxFrequency, integraXradioAtemperature, integraXradioApll, integraXradioArangeEntryIndex, integraXradioArangeDescr, integraXradioArangeTxPower, integraXradioArangeTxFrequency, integraXradioBtxPower, integraXradioBtxFrequency, integraXradioBrxLevel, integraXradioBrxLevelState, integraXradioBside, integraXradioBtxMute, integraXradioBtxMuteDuration, integraXradioBduplexShift, integraXradioBrxFrequency, integraXradioBtemperature, integraXradioBpll, integraXradioBrangeEntryIndex, integraXradioBrangeDescr, integraXradioBrangeTxPower, integraXradioBrangeTxFrequency } STATUS current DESCRIPTION "Radio group." ::= { integraXGroups 2 } integraXModemGroup OBJECT-GROUP OBJECTS { integraXmodemAacquireStatus, integraXmodemAnormalizedMse, integraXmodemAfecLoad, integraXmodemAxpdEst, integraXmodemAacquireLastStatusDetails, integraXmodemAtemperature, integraXmodemArxModulation, integraXmodemAtxModulation, integraXmodemArxCapacity, integraXmodemAtxCapacity, integraXmodemAacmEngine, integraXmodemAcarrierOffset, integraXmodemAcountTime, integraXmodemAerroredBlock, integraXmodemAerroredSecond, integraXmodemAseverelyErroredSecond, integraXmodemAbackgroundBlockError, integraXmodemAtotalBlockNumber, integraXmodemAerroredSecondRatio, integraXmodemAseverelyErroredSecondRatio, integraXmodemAbackgroundBlockErrorRatio, integraXmodemAuptime, integraXmodemAunavailtime, integraXmodemAfecLdpcBlockCounter, integraXmodemAfecLdpcUncorrectedBlockCounter, integraXmodemAfecLdpcUncorrectedPercent, integraXmodemAfecRsBlockCounter, integraXmodemAfecRsUncorrectedBlockCounter, integraXmodemBacquireStatus, integraXmodemBnormalizedMse, integraXmodemBfecLoad, integraXmodemBxpdEst, integraXmodemBacquireLastStatusDetails, integraXmodemBtemperature, integraXmodemBrxModulation, integraXmodemBtxModulation, integraXmodemBrxCapacity, integraXmodemBtxCapacity, integraXmodemBacmEngine, integraXmodemBcarrierOffset, integraXmodemBcountTime, integraXmodemBerroredBlock, integraXmodemBerroredSecond, integraXmodemBseverelyErroredSecond, integraXmodemBbackgroundBlockError, integraXmodemBtotalBlockNumber, integraXmodemBerroredSecondRatio, integraXmodemBseverelyErroredSecondRatio, integraXmodemBbackgroundBlockErrorRatio, integraXmodemBuptime, integraXmodemBunavailtime, integraXmodemBfecLdpcBlockCounter, integraXmodemBfecLdpcUncorrectedBlockCounter, integraXmodemBfecLdpcUncorrectedPercent, integraXmodemBfecRsBlockCounter, integraXmodemBfecRsUncorrectedBlockCounter, integraXmodemBandwidth, integraXmodemModulation, integraXmodemAmodulationACMmin, integraXmodemAmodulationACMmax, integraXmodemBmodulationACMmin, integraXmodemBmodulationACMmax } STATUS current DESCRIPTION "Modem group." ::= { integraXGroups 3 } integraXSystemGroup OBJECT-GROUP OBJECTS { integraXsysCPUtemperature, integraXsysLicenseExpire, integraXsysLicenseGenStatus, integraXsysPSUvoltage, integraXsysPSUcurrent, integraXsysPSUpower, integraXsysBoardTemperature, integraXsysFreeMemory, integraXsysCPUidle, integraXsysDeviceType, integraXsysDeviceSerial, integraXsysDeviceProductModel, integraXsysFanError, integraXexecuteConfig, integraXneedStore, integraXstoreConfig, integraXsysSw1v0core, integraXsysSw1v0avdd, integraXsysSw1v2a, integraXsysSw1v5ddr, integraXsysSw1v8, integraXsysSw2v5, integraXsysSw3v3, integraXsysVttrefPs, integraXsysVttddrPs, integraXsysZq1v0, integraXsysZq1v5, integraXsysZq1v8, integraXsysZq2v5, integraXsysZq3v3, integraXsys5v0d, integraXsysSw1v2, integraXsysMdmVddcAvs, integraXsysMdm3v3, integraXsysMdm1v0aPm, integraXsysMdm1v0a, integraXsysMdm1v8a, integraXsysMdmDAC02v5a, integraXsysMdmDAC12v5, integraXsysMdmDAC22v5, integraXsysMdm1v8io, integraXsysMdm3v3io, integraXsys3v3Radio, integraXsysMdm4v0, integraXsys5v0nRadio, integraXsysCoreVddSns, integraXsys40v0RadioSns, integraXsysServicesReboot, integraXsysServicesFtpSwitch, integraXsysServicesFwCurrInfo, integraXsysServicesFwAvailView, integraXsysServicesFwRemove, integraXsysServicesFwRemoveAll, integraXsysServicesFwUpload, integraXsysServicesFwInst, integraXsysServicesFwSwitchRunning, integraXsysServicesFwSwitchNext } STATUS current DESCRIPTION "System group." ::= { integraXGroups 4 } integraXEthernetGeneralGroup OBJECT-GROUP OBJECTS { integraXifPortStatIndex, integraXifPortStatDescr, integraXifPortType, integraXifPortMtu, integraXifPortHighSpeed, integraXifPortPhysAddress, integraXifPortAdminStatus, integraXifPortOperStatus, integraXifPortLastChange, integraXifPortAutoneg, integraXifPortDuplex, integraXifPortSyncEthActive, integraXifPortSyncEthPrio, integraXifPortFlowControl, integraXifPortStcIndex, integraXifPortStcDescr, integraXifTimePassed, integraXifIngressPackets, integraXifIngressBytes, integraXifEgressPackets, integraXifEgressBytes, integraXifEtherRxOversizePkts, integraXifEtherTxOversizePkts, integraXifReceivedPkts64Octets, integraXifTransmittedPkts64Octets, integraXifReceivedPkts65to127Octets, integraXifTransmittedPkts65to127Octets, integraXifReceivedPkts128to255Octets, integraXifTransmittedPkts128to255Octets, integraXifReceivedPkts256to511Octets, integraXifTransmittedPkts256to511Octets, integraXifReceivedPkts512to1023Octets, integraXifTransmittedPkts512to1023Octets, integraXifReceivedPkts1024to1518Octets, integraXifTransmittedPkts1024to1518Octets, integraXifIfInBroadcastPkts, integraXifIfOutBroadcastPkts, integraXifIfInMulticastPkts, integraXifIfOutMulticastPkts, integraXifIngressBPS, integraXifIngressPPS, integraXifEgressBPS, integraXifEgressPPS, integraXifAllCoSQoutPackets, integraXifAllCoSQoutBytes, integraXifAllCoSQdroppedPackets, integraXifAllCoSQdroppedBytes, integraXifProcessedRxPackets, integraXifProcessedRxBytes, integraXnetCfgIPaddress, integraXnetCfgIPmask, integraXnetCfgIPgateway, integraXnetCfgRemoteIPaddress, integraXifLspPortAdminState, integraXifLspPortList, integraXifLspPortStatus } STATUS current DESCRIPTION "A collection to objects, providing info applicable to all network interfaces." ::= { integraXGroups 5 } integraXEthernetMiiPortGroup OBJECT-GROUP OBJECTS { integraXifEtherStatsMulticastPkts, integraXifEtherStatsBroadcastPkts, integraXifEtherStatsPkts64Octets, integraXifEtherStatsPkts65to127Octets, integraXifEtherStatsPkts128to255Octets, integraXifEtherStatsPkts256to511Octets, integraXifEtherStatsPkts512to1023Octets, integraXifEtherStatsPkts1024to1518Octets, integraXifEtherStatsOversizePkts, integraXifEtherStatsOctets, integraXifEtherStatsPkts, integraXifEtherStatsTXNoErrors, integraXifEtherStatsRXNoErrors, integraXifEtherStatsPkts1519to1522Octets, integraXifIfInOctets, integraXifIfOutOctets, integraXifDot1dTpPortInFrames, integraXifDot1dTpPortOutFrames, integraXifDot3InPauseFrames, integraXifDot3OutPauseFrames, integraXifEtherStatsUndersizePkts, integraXifEtherStatsFragments, integraXifEtherStatsCRCAlignErrors, integraXifEtherStatsJabbers } STATUS current DESCRIPTION "A collection of objects, providing info applicable only to MII group interfaces." ::= { integraXGroups 6 } END