--******************************************************************* --* SAGEM SA * --******************************************************************* --******************************************************************* -- Filename: GigE -- File type: .mib -- -- Description: SNMPc source Mib file. -- The MIB module defines the gigabitEthernet card managment in Adr2500c -- -- Version: 19 11 2002 -- -- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS -- -- Contact: D. Mobuchon, F. Bonnevialle -- -- History: -- Name: S.LAURENT -- Date: 22 05 2002 -- Desc: original -- -- Name: F.Bonnevialle -- Date: 15 11 2002 -- Desc: Modification for SilverCreek Compiler -- --******************************************************************* --******************************************************************* --* Copyright (c) 2002, SAGEM , All rights reserved. * --******************************************************************* --******************************************************************* -- MIB: GIGE-MIB --******************************************************************* GIGE-MIB DEFINITIONS ::= BEGIN --******************************************************************* -- IMPORTS --******************************************************************* IMPORTS adr2500c FROM ADR2500C-MIB SagemBoolean, Severity FROM EQUIPMENT-MIB MODULE-IDENTITY,OBJECT-TYPE,Counter64 FROM SNMPv2-SMI DisplayString, PhysAddress FROM SNMPv2-TC; gige MODULE-IDENTITY LAST-UPDATED "0205220000Z" ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd" CONTACT-INFO " " DESCRIPTION "The MIB module specific for GigE module of Adr2500c" ::= { adr2500c 10 } --******************************************************************* --* Gige part --******************************************************************* BandwidthSize ::= INTEGER { none(0), stm1(1), stm4(4), stm16(16), stm64(64) } gigeNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of gigabitEthernet cards in equipment." ::= { gige 10 } gigeTable OBJECT-TYPE SYNTAX SEQUENCE OF GigeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of gigabitEthernet cards in equipment." ::= { gige 11 } gigeEntry OBJECT-TYPE SYNTAX GigeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular gigabitEthernet card of the equipment." INDEX { gigeIndex } ::= { gigeTable 1 } GigeEntry ::= SEQUENCE { gigeIndex INTEGER, -- boardIndex gigeSdhBandwidth BandwidthSize, gigeAutoTest SagemBoolean, gigeWarmStart SagemBoolean } gigeIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular gigabitEthernet card of the equipment. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware" ::= { gigeEntry 1 } gigeSdhBandwidth OBJECT-TYPE SYNTAX BandwidthSize MAX-ACCESS read-write STATUS current DESCRIPTION "This field set the size of the SDH Bandwidth which is allocated to the gigabitEthernet card." ::= { gigeEntry 2 } gigeAutoTest OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, an autotest is executed on the gigabitEthernet card." ::= { gigeEntry 3 } gigeWarmStart OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, a warmStart is launched on the gigabitEthernet card." ::= { gigeEntry 4 } -- End of gige description --******************************************************************* --* Maintenance part --******************************************************************* LoopbackGE ::= INTEGER { none(0), -- GE-SDH Bidirectionnal Transmission local1(1), -- GE-GE Loopback (above GFP) local2(2), -- GE-GE Loopback (beyong GFP) local3(3), -- GE-GE Loopback (into SERDES) local4(4), -- GE-GE Loopback (into GMAC Bloc) remote(10) -- SDH-SDH Loopback (into Tramer) } maintenanceNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of gigabitEthernet ports in equipment." ::= { gige 20 } maintenanceTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintenanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of gigabitEthernet ports in equipment." ::= { gige 21 } maintenanceEntry OBJECT-TYPE SYNTAX MaintenanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular gigabitEthernet port of the equipment." INDEX { maintenanceIndex } ::= { maintenanceTable 1 } MaintenanceEntry ::= SEQUENCE { maintenanceIndex INTEGER, -- channelIndex = nspiTTPIndex maintenanceAutoTest SagemBoolean, maintenanceLoopback LoopbackGE, maintenancePRBSSent DisplayString, maintenancePRBSReceived DisplayString, maintenanceResetAllCounters SagemBoolean, maintenanceResetLanCounters SagemBoolean, maintenanceResetGfpCounters SagemBoolean, maintenanceResetQosCounters SagemBoolean } maintenanceIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular gigabitEthernet port of the equipment. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware" ::= { maintenanceEntry 1 } maintenanceAutoTest OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, an autotest is executed on the gigabitEthernet port." ::= { maintenanceEntry 2 } maintenanceLoopback OBJECT-TYPE SYNTAX LoopbackGE MAX-ACCESS read-write STATUS current DESCRIPTION "This field set a loopback mode to a particular gigabitEthernet port." ::= { maintenanceEntry 3 } maintenancePRBSSent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to sent a PRBS frame on a particular gigabitEthernet port." ::= { maintenanceEntry 4 } maintenancePRBSReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value is the actual PRBS frame received in the particular gigabitEthernet port." ::= { maintenanceEntry 5 } maintenanceResetAllCounters OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, all counters attached to this interface are deleted." ::= { maintenanceEntry 6 } maintenanceResetLanCounters OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, all QoS counters attached to this interface are deleted." ::= { maintenanceEntry 7 } maintenanceResetGfpCounters OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, all Gfp counters attached to this interface are deleted." ::= { maintenanceEntry 8 } maintenanceResetQosCounters OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to true, all Qos counters attached to this interface are deleted." ::= { maintenanceEntry 9 } -- End of maintenance part --******************************************************************* --* QoS part --******************************************************************* QosType ::= INTEGER { none(0), pauseMode(1), userPriority(2), vlanId(3), balanced(4), ipv4TOS(10), ipv6TClass(11), dscp(13) } CongestionControl ::= INTEGER { none(0), red(1), -- Random Early Detection wred(2) -- Weighted Random Early Detection } SchedulingSystem ::= INTEGER { unknown(0), spq(1), -- Strict Priority Queuing wfq(4), -- Weighted Fair Queuing cbwfq(5), -- Class-Based Weighted Fair Queuing wrr(10) -- Weighted Round Robbin } qosNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Quality of Service set in equipment. This number match to channelNumber because there is only one Qos per Sdh Channel. = number of entries in qosTable" ::= { gige 30 } qosTable OBJECT-TYPE SYNTAX SEQUENCE OF QosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of Qos in equipment." ::= { gige 31 } qosEntry OBJECT-TYPE SYNTAX QosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular qos of the equipment." INDEX { qosIndex } ::= { qosTable 1 } QosEntry ::= SEQUENCE { qosIndex INTEGER, -- channelIndex = nspiTTPIndex qosClassNumber INTEGER, qosType QosType, qosCongestionControl CongestionControl, qosSchedulingSystem SchedulingSystem, qosBwREnable SagemBoolean, qosHCInCCDiscardsGe Counter64, qosHCInCCDiscardsWan Counter64 } qosIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular QoS of the equipment. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware" ::= { qosEntry 1 } qosClassNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to choose the number of CoS defined for the QoS" ::= { qosEntry 2 } qosType OBJECT-TYPE SYNTAX QosType MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to choose the type of Qos" ::= { qosEntry 3 } qosCongestionControl OBJECT-TYPE SYNTAX CongestionControl MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to choose a mechanism to manage congestion problems. Some Type of Qos force the value of this field. " ::= { qosEntry 4 } qosSchedulingSystem OBJECT-TYPE SYNTAX SchedulingSystem MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to choose a mechanism to manage congestion problems. " ::= { qosEntry 5 } qosBwREnable OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to activate or desactivate the Sdh throughput reservation feature. " ::= { qosEntry 6 } qosHCInCCDiscardsGe OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received on the GE interface which were discarded to prevent from switch saturation" ::= { qosEntry 7 } qosHCInCCDiscardsWan OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received on the WAN interface which were discarded to prevent from switch saturation" ::= { qosEntry 8 } -- End of QoS part --******************************************************************* --* CoS part --******************************************************************* CosId ::= INTEGER { cos0(0), cos1(1), cos2(2), cos3(3), cos4(4), cos5(5), cos6(6), cos7(7) } cosNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Class of Service set in equipment = number of entries in cosTable = qosNumber * qosClassNumber" ::= { gige 40 } cosTable OBJECT-TYPE SYNTAX SEQUENCE OF CosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of CoS in equipment." ::= { gige 41 } cosEntry OBJECT-TYPE SYNTAX CosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular CoS of the equipment." INDEX { cosIndex } ::= { cosTable 1 } CosEntry ::= SEQUENCE { cosIndex INTEGER, cosQosId INTEGER, -- qosIndex cosId CosId, cosDefinition DisplayString, cosBwRRatioMin INTEGER, cosBwRRatioMax INTEGER, cosHCInOctets Counter64, cosHCOutOctets Counter64, cosHCInPkts Counter64, cosHCOutPkts Counter64, cosHCInCCDiscards Counter64 } cosIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular CoS of the equipment. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Its values are taken between 1 and cosNumber." ::= { cosEntry 1 } cosQosId OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This field allows to identify which QoS this Class is belonging. Its values must match to qosIndex." ::= { cosEntry 2 } cosId OBJECT-TYPE SYNTAX CosId MAX-ACCESS read-only STATUS current DESCRIPTION " This field identify the class of Service." ::= { cosEntry 3 } cosDefinition OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This optional textual field brings some precisions about the CoS configuration. " ::= { cosEntry 4 } cosBwRRatioMin OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "When the qosBwREnable field is set to True, then this field allows to configure the guaranted percentage of SDH throughput which must be booked up for the CoS" ::= { cosEntry 5 } cosBwRRatioMax OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "When the qosBwREnable field is set to True, then this field allows to configure the maximum percentage of SDH throughput which can be booked up for the CoS" ::= { cosEntry 6 } cosHCInOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets received on the GE interface (excluding framing characters preambule and sfd) and belonging to a CosId packet" ::= { cosEntry 7 } cosHCOutOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd) and belonging to a CosId paket" ::= { cosEntry 8 } cosHCInPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets received on the GE interface (excluding framing characters preambule and sfd) and belonging to a CosId packet" ::= { cosEntry 9 } cosHCOutPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd) and belonging to a CosId paket" ::= { cosEntry 10 } cosHCInCCDiscards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CosId packets received on the GE interface which were discarded by RED/WRED/BandWidthReservation to prevent from congestion." ::= { cosEntry 11 } -- End of CoS part --******************************************************************* --* GFP part --******************************************************************* GfpFailure ::= INTEGER { none(0), oofd(1), lofd(2), fdsc(3) } GfpState ::= INTEGER(0..2147483647) -- { -- none(0), -- (1), -- (2), -- (3) -- } gfpNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "ports Number of the Gfp layer. = number of entries in gfpTable " ::= { gige 50 } gfpTable OBJECT-TYPE SYNTAX SEQUENCE OF GfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of gfp port in the equipment." ::= { gige 51 } gfpEntry OBJECT-TYPE SYNTAX GfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular gfp port of the equipment." INDEX { gfpIndex } ::= { gfpTable 1 } GfpEntry ::= SEQUENCE { gfpIndex INTEGER, -- channelIndex gfpHCInPkts Counter64, gfpHCInIdlePkts Counter64, gfpHCInCorruptedPkts Counter64, gfpHCInErrors Counter64, gfpHCInCorrectedPkts Counter64, gfpHCFCSErrors Counter64, gfpHCInOctets Counter64, gfpHCOutPkts Counter64, gfpHCOutIdlePkts Counter64, gfpHCOutOctets Counter64, gfpIdleRate INTEGER, gfpSendingRate INTEGER, gfpState GfpState, gfpAdminStatus INTEGER, gfpOperStatus INTEGER, gfpMonitor SagemBoolean, gfpFailure GfpFailure, gfpSeverity Severity, gfpOOFD Severity, gfpLOFD Severity, gfpFDSC Severity } gfpIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular gfp port in the equipment. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Its values are mapped to channelIndex values." ::= { gfpEntry 1 } gfpHCInPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of packets received on the Gfp interface" ::= { gfpEntry 2 } gfpHCInIdlePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of Idle frames received on the Gfp interface" ::= { gfpEntry 3 } gfpHCInCorruptedPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of mismatched packets received on the Gfp interface." ::= { gfpEntry 4 } gfpHCInErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of mismatched packets that have been discarded. " ::= { gfpEntry 5 } gfpHCInCorrectedPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of mismatched packets received on the Gfp interface that have been corrected. " ::= { gfpEntry 6 } gfpHCFCSErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received on the Gfp interface that are an integral number of octets in length but do not pass the FCS check. " ::= { gfpEntry 7 } gfpHCInOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of Octets received on the Gfp interface" ::= { gfpEntry 8 } gfpHCOutPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of packets transmitted out of the Gfp interface" ::= { gfpEntry 9 } gfpHCOutIdlePkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of Idle frame transmitted out of the Gfp interface" ::= { gfpEntry 10 } gfpHCOutOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " The total number of packets transmitted out of the Gfp interface" ::= { gfpEntry 11 } gfpIdleRate OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION " The received Idle frames rate on a particular gfp port. " ::= { gfpEntry 12 } gfpSendingRate OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION " The sent frames rate on a particular gfp port. " ::= { gfpEntry 13 } gfpState OBJECT-TYPE SYNTAX GfpState MAX-ACCESS read-only STATUS current DESCRIPTION "This field allows to know in which state this gfp port is working." ::= { gfpEntry 14 } gfpAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the gfp port. The testing(3) state indicates that no operational packets can be passed." ::= { gfpEntry 15 } gfpOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the gfp port. The testing(3) state indicates that no operational packets can be passed." ::= { gfpEntry 16 } gfpMonitor OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to false, the failure detection is stopped for this gfp port." ::= { gfpEntry 17 } gfpFailure OBJECT-TYPE SYNTAX GfpFailure MAX-ACCESS read-only STATUS current DESCRIPTION "Active failures on channel" ::= { gfpEntry 18 } gfpSeverity OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to failure severity for gfp port." ::= { gfpEntry 19 } gfpOOFD OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-write STATUS current DESCRIPTION "Severity associated with Out of Frame Delineation failure for gfp port." ::= { gfpEntry 20 } gfpLOFD OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-write STATUS current DESCRIPTION "Severity associated with Loss Of Frame Delineation failure for gfp port." ::= { gfpEntry 21 } gfpFDSC OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-write STATUS current DESCRIPTION "Severity associated with Frame Delineation State Change failure for gfp port." ::= { gfpEntry 22 } -- End of GFP part --******************************************************************* --* PAUSE part --******************************************************************* PauseFailure ::= INTEGER { none(0), pauseModeRejected(1) } pauseNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of ports in the equipment which accept Pause mechanism = number of entries in pauseTable " ::= { gige 60 } pauseTable OBJECT-TYPE SYNTAX SEQUENCE OF PauseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of Ethernet port in the equipment which accept Pause mechanism." ::= { gige 61 } pauseEntry OBJECT-TYPE SYNTAX PauseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular Ethernet port of the equipment." INDEX { pauseIndex } ::= { pauseTable 1 } PauseEntry ::= SEQUENCE { pauseIndex INTEGER, -- Lan ifIndex pauseTime INTEGER, pauseBetweenTime INTEGER, pauseMacSA PhysAddress, pauseMacDA PhysAddress, pauseCHT INTEGER, pauseCLT INTEGER, pauseMonitor SagemBoolean, pauseFailure PauseFailure, pauseSeverity Severity, pauseModeRejected Severity } pauseIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value which identify a particular Ethernet Physical port of a gigabitEthernet card. The value of this index is a constant value assigned to an entry at equipment design time. It is usualy related to harware. Its values are mapped to IfIndex values of Lan Ports." ::= { pauseEntry 1 } pauseTime OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to set the Time during which the linkPartner stop any transmission. The Unit used is the time slot (= 512 ns)." ::= { pauseEntry 2 } pauseBetweenTime OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to set the Time between two Pause Frames transmission. The Unit used is the time slot (= 512 ns)." ::= { pauseEntry 3 } pauseMacSA OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The physical address of the Ethernet port. This address is used to fill the SourceAddress field of any Pause Frame which is trasmitted by the LinkPartner." ::= { pauseEntry 4 } pauseMacDA OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The physical address used to fill the DestinationAddress field of any Pause Frame which is transmitted by the LinkPartner." ::= { pauseEntry 5 } pauseCHT OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to configure the credit High Threshold of Pause mechanism." ::= { pauseEntry 6 } pauseCLT OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to configure the credit Low Threshold of Pause mechanism." ::= { pauseEntry 7 } pauseMonitor OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "When the value of this field is set to false, the failure detection is stopped for this Ethernet port." ::= { pauseEntry 10 } pauseFailure OBJECT-TYPE SYNTAX PauseFailure MAX-ACCESS read-only STATUS current DESCRIPTION "Active failures in the pause mechanism of the Ethernet port." ::= { pauseEntry 11 } pauseSeverity OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to severity associated to the current pause failure." ::= { pauseEntry 12 } pauseModeRejected OBJECT-TYPE SYNTAX Severity MAX-ACCESS read-write STATUS current DESCRIPTION "This field allows to configure the Severity associated with Pause Mode Rejected failure for Ethernet port." ::= { pauseEntry 13 } -- End of Pause part END