--******************************************************************* --* SAGEM, IONOS * --******************************************************************* --******************************************************************* -- -- Filename: perf -- -- File type: .mib -- -- -- Description: SNMP source Mib file. -- -- Describes performance records. -- -- -- Version: 19 11 2002 -- -- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS -- -- Contact: D. Mobuchon, F. Bonnevialle -- -- History: -- Version: Date: 25 10 1999 -- Version: MIB-P0-301199 Date: 30 11 1999 -- -- Name: F.Bonnevialle -- Date: 15 11 2002 -- Desc: Modification for SilverCreek Compiler --******************************************************************* --******************************************************************* --* Copyright (c) 2002, SAGEM , All rights reserved. * --******************************************************************* --******************************************************************* -- MIB: PERFORMANCE-MIB --******************************************************************* PERFORMANCE-MIB DEFINITIONS ::= BEGIN --******************************************************************* -- IMPORTS --******************************************************************* IMPORTS sagemDr FROM SAGEM-DR-MIB IntDateTime FROM EQUIPMENT-MIB MODULE-IDENTITY,OBJECT-TYPE,Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI TimeTicks FROM RFC1155-SMI DisplayString FROM SNMPv2-TC ; -- TRAP-TYPE FROM RFC-1215; performance MODULE-IDENTITY LAST-UPDATED "0211150000Z" ORGANIZATION "SAGEM/DR Tolbiac Centre" CONTACT-INFO " " DESCRIPTION " Modification: Date: 15 11 2002 Description: sagemDr replace sagem-dr NOTIFICATION-TYPE replace TRAP-TYPE Modification: Date: 20 12 1999 Description: modification of comments Modification: Date: 25 11 1999 Name: thresholdUas,thresholdSes,thresholdEs,thresholdBbe Description: read-write instead of read-only Modification: Date: 19 11 1999 Name: Description: modification of comments Creation: Date: 25 10 1999 Description: The MIB module describes performance records. It also describes the traps that could be sent either to notify a threshold or a non null quality record, for the devices that support that feature. " ::= { sagemDr 102 } --******************************************************************* NearFar ::= INTEGER { near (1), far(2) } perfClear OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "When a set command is issued on this variable, this clears a part of the performance record depending on the value of the oid: performance : all the performance records cptTable : all the counter table uasTable : all the unavailable periods table oid : the counter and uas records of this object An equipment may implement only a subset of these commands." ::= { performance 1 } --******************************************************************* -- Performance over the ports -- This table contains the history of the quality counters -- When a Date is used as index the index value is MAXDate-Date -- to keep a lexicographic order. cptNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of used records (rows) in 'cptTable'." ::= { performance 2 } cptTable OBJECT-TYPE SYNTAX SEQUENCE OF CptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of cpt in equipment." ::= { performance 3 } cptEntry OBJECT-TYPE SYNTAX CptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular cpt of the equipment." INDEX { cptObject, cptNearFar, cptDuration, cptDate } ::= { cptTable 1 } CptEntry ::= SEQUENCE { cptObject OBJECT IDENTIFIER, cptName DisplayString, cptNearFar NearFar, cptDuration TimeTicks, cptDate IntDateTime, cptUAS Gauge32, cptSES Gauge32, cptES Gauge32, cptBBE Gauge32 } cptObject OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to the function/interface from which this reccord was taken" ::= { cptEntry 1 } cptName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "A text string which identifies the object localisation. For the structure of this string, see 'logName' in the log MIB " ::= { cptEntry 2 } cptNearFar OBJECT-TYPE SYNTAX NearFar MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates near or far performance record" ::= { cptEntry 3 } cptDuration OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The full duration of measurement for the record. This table contains either logged entries and current ones. For curent performance counters, it is not the actual mesured duration, but the duration from start to normal end. The standard durations are 15 minutes and 24 hours; the value can be coded in TimeTicks or in minute (see the variable 'perfDurationUnit')" ::= { cptEntry 4 } cptDate OBJECT-TYPE SYNTAX IntDateTime MAX-ACCESS read-only STATUS current DESCRIPTION "When the record had started." ::= { cptEntry 5 } cptUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of UnAvailable Seconds mesured." ::= { cptEntry 6 } cptSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Severely Errored Seconds mesured." ::= { cptEntry 7 } cptES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Errored Seconds mesured." ::= { cptEntry 8 } cptBBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Background Errors Blocks mesured." ::= { cptEntry 9 } --******************************************************************* -- Unavailable periods (uap) -- This table contains the unavailable period records logged --by the system uapNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of unavailable period records stored in the 'uapTable'." ::= { performance 4 } uapTable OBJECT-TYPE SYNTAX SEQUENCE OF UapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of unavailable period records in equipment." ::= { performance 5 } uapEntry OBJECT-TYPE SYNTAX UapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular unavailable period of the equipment." INDEX { uapObject, uapNearFar, uapBegin } ::= { uapTable 1 } UapEntry ::= SEQUENCE { uapObject OBJECT IDENTIFIER, uapName DisplayString, uapNearFar NearFar, uapBegin IntDateTime, uapEnd IntDateTime } uapObject OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to the function/interface from witch this reccord was taken." ::= { uapEntry 1 } uapName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "A text string which identifies the object localisation. For the structure of this string, see 'logName' in the log MIB " ::= { uapEntry 2 } uapNearFar OBJECT-TYPE SYNTAX NearFar MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates near or far performance record" ::= { uapEntry 3 } uapBegin OBJECT-TYPE SYNTAX IntDateTime MAX-ACCESS read-only STATUS current DESCRIPTION "When the unavailable period has started." ::= { uapEntry 4 } uapEnd OBJECT-TYPE SYNTAX IntDateTime MAX-ACCESS read-only STATUS current DESCRIPTION "When the unavailable period has finished." ::= { uapEntry 5 } --******************************************************************* -- Threshold values for performance threshold configuration -- A record on this table contains the confuguration the threshold -- for a interface or a interface type -- This table must be initialized by the equipment during its restart -- The write access authorization of this table is optional thresholdNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of threshold in equipment." ::= { performance 6 } thresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF ThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of threshold in equipment." ::= { performance 7 } thresholdEntry OBJECT-TYPE SYNTAX ThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular threshold of the equipment." INDEX { thresholdObject, thresholdNearFar, thresholdDuration, thresholdType } ::= { thresholdTable 1 } ThresholdEntry ::= SEQUENCE { thresholdObject OBJECT IDENTIFIER, thresholdName DisplayString, thresholdNearFar NearFar, thresholdDuration TimeTicks, thresholdType INTEGER, thresholdUas INTEGER, thresholdSes INTEGER, thresholdEs INTEGER, thresholdBbe INTEGER } thresholdObject OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to the interface or the interface type to which these parameters apply." ::= { thresholdEntry 1 } thresholdName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "A text string which identifies the interface localisation. For the structure of this string, see 'logName' in the log MIB " ::= { thresholdEntry 2 } thresholdNearFar OBJECT-TYPE SYNTAX NearFar MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates near or far performance threshold. Equipment may or may not implement far threshold." ::= { thresholdEntry 3 } thresholdDuration OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The normal duration of the counter with which the threshold is associed. The standard durations are 15 minutes and 24 hours; " ::= { thresholdEntry 4 } thresholdType OBJECT-TYPE SYNTAX INTEGER { raise(1), clear(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "When set to `raise' the event threshold exceded is generated when one of the corresponding counter cross its theshold. When set to `clear', the event threshold exceded is cleared when there is no counters above of its corresponding threshold. The `clear'thresholds are optionnal(the standard value is zero) " ::= { thresholdEntry 5 } thresholdUas OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of unavailable seconds within a counting period above which a performance event is issued for the interface/function" ::= { thresholdEntry 6 } thresholdSes OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of severely errored seconds within a counting period above which a performance event is issued for the interface/function" ::= { thresholdEntry 7 } thresholdEs OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of errored seconds within a counting period above which a performance event is issued for the interface/function" ::= { thresholdEntry 8 } thresholdBbe OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of background block errors within a counting period above which a performance event is issued for the interface/function" ::= { thresholdEntry 9 } -- *************************************************************** -- perfDurationUnit OBJECT-TYPE -- SYNTAX INTEGER {timeTicks (1), minutes (2)} -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Unit of the performance duration used in this MIB." -- ::= { performance 8 } -- -- *************************************************************** -- Performance enable variables -- -- The performance enables port by port are not in this MIB -- The equipment can implement them in its proprietary MIB the -- performance . -- Also the transmission quality status port by port are not -- in this MIb -- The equipment must implement them in its proprietary MIB -- the performance -- performanceEnable OBJECT-TYPE -- SYNTAX SagemBoolean -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- It is a global enable of the performance in the equipment -- The default value of this variable is 'false' -- " -- ::= { performance 9 } -- perfTrapEnable OBJECT-TYPE -- SYNTAX SagemBoolean -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- It is a global enable of the performance trap sending -- The default value of this variable is 'true' -- " -- ::= { performance 10 } -- perfThresholdTrapEnable OBJECT-TYPE -- SYNTAX SagemBoolean -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- It is a global enable of the performance threshold overflow -- trap sending -- The default value of this variable is 'true' -- " -- ::= { performance 11 } -- *************************************************************** -- qualityTrap TRAP-TYPE -- ENTERPRISE performance -- VARIABLES { cptObject, cptName, cptNearFar, -- cptDuration, cptDate, cptUAS, -- cptSES, cptES, cptBBE } -- DESCRIPTION -- " This trap allows the equipment to notify its quality records " -- ::= 2 perfTraps OBJECT IDENTIFIER ::= { performance 0 } qualityTrap NOTIFICATION-TYPE OBJECTS { cptObject, cptName, cptNearFar, cptDuration, cptDate, cptUAS, cptSES, cptES, cptBBE } STATUS current DESCRIPTION "This trap allows the equipment to notify its quality records" REFERENCE "" ::= { perfTraps 2 } END