--******************************************************************* --* SAGEM SA * --******************************************************************* --******************************************************************* -- Filename: connection -- File type: .mib -- -- Description: SNMPc source Mib file. -- -- Version: 19 11 2002 -- -- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS -- -- Contact: D. Mobuchon, F. Bonnevialle -- -- History: -- Name: F.Bonnevialle -- Date: 12 12 2000 -- Desc: original -- -- Name: S.LAURENT -- Date: 22 02 2001 -- Desc: * Access right Modifications (from "Read-write" to "Read-Only") of some -- LinkTable variables . -- Use the Xcon vector to add or delete TableLink elements. -- * Modification of the LinkDirection enum in order to -- match up its values with those of the ADR equipment. -- * Modification of Xcon vector in order to add the new variable xconAction, -- which indicates the kind of the action (Creation(1) or Deletion(2)) -- * The linkImplementation variable, which should allow to reserve a -- connection without physical implementation, is maintained (for a next use) -- but is not implemented in the SNMP Agent (its value is always set to TRUE) -- * The 6 subelements of the name of the connexion have been replaced by -- a unique variable: xconName (which matches to M1400 format) -- -- Name: S.LAURENT -- Date: 19 04 2001 -- Desc: * Modification of the CTPType values -- -- Name: S.LAURENT -- Date: 25 04 2001 -- Desc: * Change the MIB number: {Sagem 120} -> {Sagem 108} -- -- Name: S.LAURENT -- Date: 10 08 2001 -- Desc: * LinkImplementation Access right Modification -- (from "Read-Only" to "Read-Write") -- -- Name: S.LAURENT -- Date: 22 05 2002 -- Desc: * Add a new CTPType Value: nspi(100) -- -- Name: F.Bonnevialle -- Date: 15 11 2002 -- Desc: Modification for SilverCreek Compiler -- --******************************************************************* --******************************************************************* --* Copyright (c) 2002, SAGEM , All rights reserved. * --******************************************************************* --******************************************************************* -- MIB: XCONNECTION-MIB --******************************************************************* XCONNECTION-MIB DEFINITIONS ::= BEGIN --******************************************************************* -- IMPORTS --******************************************************************* IMPORTS sagemDr FROM SAGEM-DR-MIB SagemBoolean FROM EQUIPMENT-MIB MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; --RFC1213-MIB; xconnection MODULE-IDENTITY LAST-UPDATED "0205220000Z" ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd" CONTACT-INFO " " DESCRIPTION "The MIB module describes connection in physical layer of transmission equipements such as pdh/sdh mux and cross connect. This mib assumes that terminaison point are provided by other mibs, such as sdh.mib. xconnection is a particular case of SubNetworkConnection defined in ETS 300 653" ::= { sagemDr 108} -- linkTable link OBJECT IDENTIFIER ::= { xconnection 10 } -- create/delete connection xcon OBJECT IDENTIFIER ::= { xconnection 30 } --******************************************************************* -- Link --******************************************************************* TrafficStatus ::= INTEGER { none(0), -- Future case of a non-implemented link working(1), protection(2) } ProtectionType ::= INTEGER { none(0), snc(1) } ProtectionStatus ::= INTEGER { none(0), used(1) } LinkDirection ::= INTEGER { unidirectional(1), bidirectional(2) } CTPType ::= INTEGER { unknown(0), au(1), au4c(2), au16c(3), tu3(10), tu12(20), pdh2M (50), pdh34M (51), pdh45M (52), pdh140M (53), eth10M(60), eth100M(61), eth1G(62), nspi(100) } linkNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of cross connections in equipment." ::= { link 1 } linkTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of link in equipment. For example, a bidirectionnal connection is composed of 2 links. A SNC protected bidirectionnal connection is composed of 3 permanent links ." ::= { link 2 } linkEntry OBJECT-TYPE SYNTAX LinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A particular synchronous physical interface of the equipment." INDEX { linkIndex } ::= { linkTable 1 } LinkEntry ::= SEQUENCE { linkIndex INTEGER, linkSinkType CTPType, linkSrcType CTPType, linkCTPSink INTEGER, linkCTPSource INTEGER, linkName DisplayString, linkGroupId INTEGER, linkDirection LinkDirection, linkProtectionType ProtectionType, linkProtectionStatus ProtectionStatus, linkTrafficStatus TrafficStatus, linkImplementation SagemBoolean } linkIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "linkIndex = number of the CTP Output = sncIndex " ::= { linkEntry 1 } linkSinkType OBJECT-TYPE SYNTAX CTPType MAX-ACCESS read-only STATUS current DESCRIPTION "Kind of CTP table from which the connection is issued" ::= { linkEntry 2 } linkSrcType OBJECT-TYPE SYNTAX CTPType MAX-ACCESS read-only STATUS current DESCRIPTION "Kind of CTP table from which the connection is issued" ::= { linkEntry 3 } linkCTPSink OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this field indicates the Ouput Connection Point which composes the unidirectionnal link.It's an index in considerated TTP table linkCTPSink = linkIndex" ::= { linkEntry 4 } linkCTPSource OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this field indicates the Input Connection Point which composes the unidirectionnal link. It's an index in considerated TTP table " ::= { linkEntry 5 } linkName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A text string which identifies the name of this link. Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name. M1400 UIT-T specifies the field's format " ::= { linkEntry 6 } linkGroupId OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A group identifier is used to group links by community." ::= { linkEntry 7 } linkDirection OBJECT-TYPE SYNTAX LinkDirection MAX-ACCESS read-only STATUS current DESCRIPTION "Unidirectional or Bidirectionnal connections." ::= { linkEntry 8 } linkProtectionType OBJECT-TYPE SYNTAX ProtectionType MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this field indicates the kind of wanted link protection. The default value is NONE. if value is changed in Snc(1)then an entry is created in Snc table with the same index. But this table has to be completed (by setting the PIC,...) to obtain a configured protection. if value is changed in None(0)then the associated entry in Snc table is deleted. When the value is set to Snc for a particular entry of LinkTable, other links which are in relation (of direction or protection) with this main link remain setting to None for this field. But all links are set to the USED(1) value in the next field (linkProtectionStatus)" ::= { linkEntry 9 } linkProtectionStatus OBJECT-TYPE SYNTAX ProtectionStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this field indicates if the link is used directly or not in a Snc protection. For a non-protected link, this field is mandatory set to None. The field value particulary allow to know the hability of link deletion." ::= { linkEntry 10 } linkTrafficStatus OBJECT-TYPE SYNTAX TrafficStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this field indicates where is the traffic. For a non-protected link, this field is mandatory set to working" ::= { linkEntry 11 } linkImplementation OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION "Actually, this variable is not implemented (always set to TRUE). But it could be used to allow to reserve a connection without physical implementation" ::= { linkEntry 12 } --******************************************************************* -- xcon : creation/deletion of Xconnection -- This vector has been created to allow to: -- * create or delete Xconnection in an atomic way (no need to use Set All command) -- * keep critical variable of linkTable (such as linkIndex) in a Read-Only Access -- * get back a special message in case of trouble. --******************************************************************* XconDir ::= INTEGER { unknown(0), -- Future case of a non-implemented link unidirectional(1), bidirectional(2) } ActionType ::= INTEGER { unknown(0), creation(1), deletion(2) } xconNumber OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of connection to process." ::= { xcon 1 } xconSinkType OBJECT-TYPE SYNTAX CTPType MAX-ACCESS read-write STATUS current DESCRIPTION "Type of CTP" ::= { xcon 2 } xconSinkIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Output CTP" ::= { xcon 3 } xconSrcType OBJECT-TYPE SYNTAX CTPType MAX-ACCESS read-write STATUS current DESCRIPTION "Type of CTP" ::= { xcon 4 } xconSrcIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Input CTP" ::= { xcon 5 } xconDirection OBJECT-TYPE SYNTAX XconDir MAX-ACCESS read-write STATUS current DESCRIPTION "Bidirectionnal connections are composed of two unidirectional xcon and therefore 2 link entries." ::= { xcon 6 } xconName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charracters. Not mandatory fields. * NameSuffixX field accepts alpha-numeric characters. It's preceded by a '/' character. Maximum length is 3 characters. Not mandatory fields. * NameFunction field accepts alpha-numeric characters. It's followed by a 'S' character. Maximum length is 3 characters. Mandatory field. It represents the function code. * NameSerial field accepts 4-figure number. Not mandatory field. It represents the serial number and will be incremented automatically from the base serial number provided. For ADR2500 equipments: Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name." ::= { xcon 7 } xconAction OBJECT-TYPE SYNTAX ActionType MAX-ACCESS read-write STATUS current DESCRIPTION "Type of action: Unknown(0) or Creation(1) or deletion(2)" ::= { xcon 8 } xconProceed OBJECT-TYPE SYNTAX SagemBoolean MAX-ACCESS read-write STATUS current DESCRIPTION " This entry is use to create (set to `true'). The value of the field remains to `true' until creation is completed or has been aborted. " ::= { xcon 20 } xconDiagnostic OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A string used to help in case of trouble." ::= { xcon 21 } END