-- ---------------------------------------------------------------------------- -- -- SIAE MICROELETTRONICA s.p.a. -- -- Via Michelangelo Buonarroti, 21 -- 20093 - Cologno Monzese -- Milano -- ITALY -- -- ---------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- SIAE-CARRIER-AGGRL1-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress FROM SNMPv2-SMI InterfaceIndexOrZero FROM IF-MIB RowStatus FROM SNMPv2-TC siaeMib FROM SIAE-TREE-MIB; carrierAggr MODULE-IDENTITY LAST-UPDATED "201608230000Z" ORGANIZATION "SIAE MICROELETTRONICA spa" CONTACT-INFO "SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com " DESCRIPTION "Carrier hybrid aggregation management for SIAE equipments. " REVISION "201608230000Z" DESCRIPTION "Initial version 01.00.00. " ::= { siaeMib 104 } ---------------------------------------------------------------------------------- -- Hybrid Radio LAG MIB ---------------------------------------------------------------------------------- -- -- This MIB manage the configuration and the status of a a carrier belonging to -- an hybrid radio aggregation. SNMP manager must create an instance of -- Sensor Table and attach it to an Radio-interface (ifIndex in ifTable). -- Now SNMP manager must create an instance of Actuator Table and attach it to -- an LAN-interface (ifIndex in ifTable). After enabling admin status of both -- sensor and actuator, the carrier path is enabled. -- Every interface (Radio or Lan) that can be used in this feature, have the -- needed capabilities in "sm_ifext.mib". The number of Radio-interfaces is -- related to the link-configuration (1+0, 2+0,...) too; so the related -- capabilities could dynamically change according to link-configuration. -- When a carrier path is enabled, alarms are detected and notified to N.E. -- aggregator. A further feature can be enabled: the hitless-Radio-Lag. It offers -- the possibility to notify (to N.E. aggregator) whether a radio is working -- in a "Good Zone"-ACM, a "Hitless-Zone"-ACM or a "Bad-Zone"-ACM. -- Such a trigger is used to dynamically exclude/include a carrier path from/in -- an aggregation without loss of frames. ---------------------------------------------------------------------------------- ------ Beginning ------------------------------------------------------------- -- MIB objects carrierAggrMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01." ::= {carrierAggr 1} ------- Begin of carrierAggrSensorTable -- carrierAggrSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF CarrierAggrSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with Radio(s) interface(s) that can be associated to an entry of carrierAggrActuatorTable." ::= {carrierAggr 2} carrierAggrSensorEntry OBJECT-TYPE SYNTAX CarrierAggrSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the carrierAggrSensorTable." INDEX {carrierAggrSensorIndex} ::= {carrierAggrSensorTable 1} CarrierAggrSensorEntry ::= SEQUENCE { carrierAggrSensorIndex INTEGER, carrierAggrSensorRowstatus RowStatus, carrierAggrSensorAdminStatus INTEGER, carrierAggrSensorIfIndex InterfaceIndexOrZero, carrierAggrSensorHitlessCapability BITS, carrierAggrSensorHitlessBehaviour INTEGER, carrierAggrSensorHitlessMode INTEGER, carrierAggrSensorHitlessProfile INTEGER, carrierAggrSensorHitlessStatus INTEGER } carrierAggrSensorIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the index of carrierAggrSensorTable." ::= {carrierAggrSensorEntry 1} carrierAggrSensorRowstatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this sensor entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: SensorIfIndex must be set to a valid ifIndex number. Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When this object is set to notInService changes may be made to carrierAggrSensorIfIndex. Other objects can be changed when carrierAggrSensorRowStatus is set to active. A sensor can not be deleted if there is any Actuator (see table carrierAggrActuatorTable) associated with it. " ::= { carrierAggrSensorEntry 2 } carrierAggrSensorAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Administative status of the sensor. The value down(1) turns off all actuators associated with this sensor. " DEFVAL { down } ::= { carrierAggrSensorEntry 3 } carrierAggrSensorIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object accepts a greater than zero value to identify an interface in ifTable. Some parameters of the radio associated to this interface is monitored and a notification is sent to all connected actuators. " ::= { carrierAggrSensorEntry 4 } carrierAggrSensorHitlessCapability OBJECT-TYPE SYNTAX BITS { hitlessAvailable(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This capability is related to HITLESS Behaviour carrierAggrSensorHitlessBehaviour." ::= {carrierAggrSensorEntry 5} carrierAggrSensorHitlessBehaviour OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The hitless behaviour. When enabled, data related to the current ACM zone is notified to an external N.E. aggregator, so it can dynamically exclude/include the data-flow without loss of frames. It can be enabled only if carrierAggrSensorHitlessCapability is available" DEFVAL {disable} ::= {carrierAggrSensorEntry 6} carrierAggrSensorHitlessMode OBJECT-TYPE SYNTAX INTEGER { auto (1), manual (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The policy to select the hitless profile (i.e. the lowest one under which a N.E. aggregator excludes the carrier from an existing aggregation). auto(1): Tx Lower Profile + 1 is selected; manual(2): the value set in carrierAggrSensorHitlessProfile is selected. " DEFVAL { auto } ::= {carrierAggrSensorEntry 7} carrierAggrSensorHitlessProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The hitless profile in case of carrierHyAggrHitlessBehaviour set as enabled and carrierHyAggrHitlessMode set as manual. " DEFVAL { 1 } ::= {carrierAggrSensorEntry 8} carrierAggrSensorHitlessStatus OBJECT-TYPE SYNTAX INTEGER { goodZone (1), hitlessZone (2), badZone (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The working zone of the radio link." ::= {carrierAggrSensorEntry 9} -- ------- End of carrierAggrSensorTable ------- Begin of carrierAggrActuatorTable -- carrierAggrActuatorTable OBJECT-TYPE SYNTAX SEQUENCE OF CarrierAggrActuatorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with Lan(s) interface that can be associated to an entry of carrierAggrSensorTable." ::= {carrierAggr 3} carrierAggrActuatorEntry OBJECT-TYPE SYNTAX CarrierAggrActuatorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the carrierAggrActuatorTable." INDEX { carrierAggrActuatorIndex } ::= { carrierAggrActuatorTable 1 } CarrierAggrActuatorEntry ::= SEQUENCE { carrierAggrActuatorIndex INTEGER, carrierAggrActuatorRowStatus RowStatus, carrierAggrActuatorAdminStatus INTEGER, carrierAggrActuatorIfIndex InterfaceIndexOrZero, carrierAggrActuatorSensorIndex Integer32, carrierAggrActuatorConcIpAddr IpAddress } carrierAggrActuatorIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the carrier aggr Actuator inside the Network Element." ::= { carrierAggrActuatorEntry 1 } carrierAggrActuatorRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: carrierAggrActuatorIfIndex must be set to a valid ifIndex number and carrierAggrActuatorSensorIndex must be set to a valid sensor, Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When set to notInService changes may be made to carrierAggrActuatorIfIndex and carrierAggrActuatorSensorIndex. Other objects can be changed when carrierAggrActuatorRowStatus is set to active. " ::= { carrierAggrActuatorEntry 2 } carrierAggrActuatorAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Administative status of the actuator. The value down(1) turns it off. Other actuators associated with the same sensor remain active." DEFVAL { down } ::= { carrierAggrActuatorEntry 3 } carrierAggrActuatorIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object accepts a greater than zero value to identify an interface in ifTable. The notify received from the connected sensor is forwarded to the remote aggregator to signal some anomalies on this aggregated flow. " ::= { carrierAggrActuatorEntry 4 } carrierAggrActuatorSensorIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object connects this actuator to a sensor. " ::= { carrierAggrActuatorEntry 5 } carrierAggrActuatorConcIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to contain the Ip address of the equipment connected with this Lan (the concatenator unit)" ::= { carrierAggrActuatorEntry 6 } -- ------- End of carrierAggrActuatorTable ------ End group ----------------------------------------------------------------- ---------------------------------- End ------------------------------------- END