-- ---------------------------------------------------------------------------- -- -- SIAE MICROELETTRONICA s.p.a. -- -- Via Michelangelo Buonarroti, 21 -- 20093 - Cologno Monzese -- Milano -- ITALY -- -- ---------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- SIAE-EQUIP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, IpAddress, TimeTicks FROM SNMPv2-SMI DisplayString, AutonomousType FROM SNMPv2-TC InterfaceIndex FROM IF-MIB siaeMib FROM SIAE-TREE-MIB AlarmStatus, AlarmSeverityCode, alarmTrap FROM SIAE-ALARM-MIB equipTypeUnknown FROM SIAE-EQUIPTYPE-MIB; equipment MODULE-IDENTITY LAST-UPDATED "201503230000Z" ORGANIZATION "SIAE MICROELETTRONICA spa" CONTACT-INFO "SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: help@siaemic.com " DESCRIPTION "Common parameters of SIAE equipments. " REVISION "201503230000Z" DESCRIPTION "Removed alarmTrapNumber from TRAPs and IMPORTS. " REVISION "201412030000Z" DESCRIPTION "MIB version 01.00.02 Added equipIpEthDefGatewayIfIndex " REVISION "201407010000Z" DESCRIPTION "MIB version 01.00.01 Added equipIpEthVlanId and equipIpEthDefGateway " REVISION "201406230000Z" DESCRIPTION "Fixed IMPORTS clause " REVISION "201402030000Z" DESCRIPTION "Improved description of equipMibVersion " REVISION "201304160000Z" DESCRIPTION "Initial version 01.00.00 " ::= { siaeMib 1 } ---------------------------------------------------------------------------------- -- SIAE equipment GROUP ---------------------------------------------------------------------------------- -- -- The following listed objects are general object common to all SIAE equipment. -- ---------------------------------------------------------------------------------- ------ Beginning -------------------------------------------------------------- equipMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01." DEFVAL {1} ::= {equipment 1} equipCurrentTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Seconds since 1/1/1970." ::= {equipment 2} equipUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time since the system was last re-initialized (in seconds since 1/1/1970)." ::= {equipment 3} equipType OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of SIAE MICROELETTRONICA's equipment" DEFVAL { equipTypeUnknown } ::= {equipment 4} -- OBJECT-IDENTIFIER {equipment 5} is used in sm_equiptype.mib equipIpEthOsiAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address of the equipment on Ethernet-OSI interface." ::= {equipment 6} equipGosipAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "GOSIP address of the equipment." ::= {equipment 7} equipIpEthOsiNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet Mask associated with the IP address of OSI ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= {equipment 8} equipL1L2IsIsRouting OBJECT-TYPE SYNTAX INTEGER { l1 (1), l2 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "It defines the IS-IS routing type: L1 within the same area, L2 among different areas." DEFVAL {l1} ::= {equipment 9} equipStationID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string assigned by the operator to identify the specific equipment." ::= {equipment 10} equipLOMConfigEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the capabilityto connect a LOM in Configuration Mode." ::= {equipment 11} equipLOMConnected OBJECT-TYPE SYNTAX INTEGER { cleared (1), connectionAsMonitor (2), connectionAsConfig (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Signal when the LOM is connected to the NE and if the connection is for monitor or configuration." ::= {equipment 12} equipLOMConnectedTrapEnable OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2), trapEnableWithAck (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the trap generation on EquipLOMConnected status change event." DEFVAL {trapEnable} ::= {equipment 13} equipConfigChange OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a specific item. We had: Byte 0.7: change in configuration for equipment group Byte 0.6: change in configuration for userInput group Byte 0.5: change in configuration for userOutput group Byte 0.4: change in configuration for alarmLog group ...... Byte 3.7: change in a severity for equipment group Byte 3.6: change in a severity for userInput group Byte 3.5: change in a severity for userOutput group Byte 3.4: change in a severity for alarmLog group CEM can reset the change condition writing one to desired bit flag ......" ::= {equipment 14} equipConfigChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2), trapEnableWithACK (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the trap generation on EquipConfigChange status change event." DEFVAL {trapEnable} ::= {equipment 15} equipRequest OBJECT-TYPE SYNTAX INTEGER { notActive (0), -- no write-only in v2 restart (1), applyIfChange (2), revertIfChange (3), configClearAndRestart (4), routeTableClear (5), uploadBaseBand (6), offLineRouteRetrieve (7), offLineRouteSave (8), hotApplyIfChange (11), ipStackConfigure (20), osiStackConfigure (21), atuTableReset (50), siaeReservedReq1 (100), siaeReservedReq26 (125), siaeReservedReq27 (126), switchFactoryDefault (127) } MAX-ACCESS read-write STATUS current DESCRIPTION "Force Equipment Controller restart or change in interface properties." ::= {equipment 16} equipIpEthAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address of the equipment on Ethernet interface." ::= {equipment 17} equipIpEthNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet Mask associated with the IP address of ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= {equipment 18} equipOsiamParameter OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..41)) MAX-ACCESS read-write STATUS current DESCRIPTION "It defines the set-up parameter for OSI stack." ::= {equipment 19} equipIpSnmpAgentAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address used by SNMP Agent for mark generated TRAP." ::= {equipment 20} equipOperationInProgress OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A value different from 0 means operation in progress." DEFVAL {0} ::= {equipment 21} equipManagerWakeUpAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This alarm switches on when periodic connection wake-up trap starts. The trap related to this alarm is also sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable." ::= {equipment 22} equipManagerWakeUpAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the equipManagerWakeUpAlarm and enables/disables the trap generation on status change event." DEFVAL {disable} ::= {equipment 23} equipManagerWakeUpTimeout OBJECT-TYPE SYNTAX INTEGER (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the timeout elapses the equipManagerWakeUpAlarmSeverityCode is set to disable. A zero means no timeout." DEFVAL {60} ::= {equipment 24} equipManagerWakeUpIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip Address of manager wich to send a periodic connection wake-up trap. The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode differs from disable. If Ip Address equals 0 no trap will be sent." DEFVAL {'00'H} ::= {equipment 25} equipManagerWakeUpGosipAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Gosip Address of manager wich to send a periodic connection wake-up trap." ::= {equipment 26} equipManagerWakeUpTrapVersion OBJECT-TYPE SYNTAX INTEGER { trapV1 (1), trapV2 (2), trapV3 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Trap version supported by Manager to wake-up." DEFVAL {trapV1} ::= {equipment 27} equipManager1IpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "First IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present." ::= {equipment 28} equipManager2IpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Second IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present." ::= {equipment 29} equipManager1TrapVersion OBJECT-TYPE SYNTAX INTEGER { trapV1 (1), trapV2 (2), trapV3 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Trap version supported by Manager 1 (related to equipManager1IpAddr)." DEFVAL {trapV1} ::= {equipment 30} equipManager2TrapVersion OBJECT-TYPE SYNTAX INTEGER { trapV1 (1), trapV2 (2), trapV3 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Trap version supported by Manager 2 (related to equipManager2IpAddr)." DEFVAL {trapV1} ::= {equipment 31} equipDailyPmTimeZone OBJECT-TYPE SYNTAX INTEGER (-12..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Reference GMT Time Zone to close the daily P.M. records." DEFVAL {0} ::= {equipment 32} equipOperationMngtControl OBJECT-TYPE SYNTAX INTEGER { notActive (0), -- no write-only in v2 startOperation (1), confirmOperation (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "startOperation means the apply of the 'management parameters set' on the E6165 switch. confirmOperation means the backup of the 'management parameters set'." DEFVAL {0} ::= {equipment 33} equipOperationMngtInProgress OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A value different from 0 means Mngt operation in progress." ::= {equipment 34} equipLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string assigned by the operator to identify the location of specific equipment." ::= {equipment 35} equipLongitude OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Geographic coordinate that specifies the east-west position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Longitude = equipLongitude*180/2^31 This object is used with equipLatitude to locate the equipment on a map. " ::= {equipment 36} equipLatitude OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Geographic coordinate that specifies the north-south position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Latitude = equipLatitude*180/2^31 This object is used with equipLongitude to locate the equipment on a map. " ::= {equipment 37} equipIpEthVlanId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet vlan id on top of which management is built" DEFVAL { 1 } ::= { equipment 38 } equipIpEthDefGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address of the default gateway on Ethernet interface." ::= {equipment 39} equipIpEthDefGatewayIfIndex OBJECT-TYPE SYNTAX InterfaceIndex(1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address of the default gateway on Ethernet interface." ::= {equipment 40} ----------------------- -- -- The equipment Group generates the following TRAPs: -- ----------------------- equipLOMConnectedMonitor NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected} STATUS current DESCRIPTION "This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected" ::= {alarmTrap 109} equipLOMConnectedConfig NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected} STATUS current DESCRIPTION "This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected" ::= {alarmTrap 110} equipLOMDisconnected NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected} STATUS current DESCRIPTION "This event is generated by ALFOHD-NE when LOMConnected is cleared. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected" ::= {alarmTrap 111} equipConfigChangeStatus NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, equipConfigChange} STATUS current DESCRIPTION "This event is generated by ALFOHD-NE when equipConfigChange is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipConfigChange" ::= {alarmTrap 114} equipManagerWakeUpNotify NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, equipStationID, equipLocation, equipIpSnmpAgentAddress, equipGosipAddress, equipManagerWakeUpIpAddr, equipManagerWakeUpAlarm} STATUS current DESCRIPTION " This trap is sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipStationID 3) equipLocation 4) equipIpSnmpAgentAddress 5) equipGosipAddress 6) equipManagerWakeUpIpAddr 7) equipManagerWakeUpAlarm" ::= {alarmTrap 123} ------ End group ----------------------------------------------------------------- END