-- ---------------------------------------------------------------------------- -- -- SIAE MICROELETTRONICA s.p.a. -- -- Via Michelangelo Buonarroti, 21 -- 20093 - Cologno Monzese -- Milano -- ITALY -- -- ---------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- SIAE-MAB-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI RowStatus, MacAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC InterfaceIndex FROM IF-MIB siaeMib FROM SIAE-TREE-MIB; mabMib MODULE-IDENTITY LAST-UPDATED "201502170000Z" ORGANIZATION "SIAE MICROELETTRONICA spa" CONTACT-INFO "SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: help@siaemic.com " DESCRIPTION "Microwave Adaptive Bandwidth (MAB) This management information module supports the configuration of the MW Capacity Management (MCM) feature developed by SIAE MICROELETTRONICA and Cisco that offers reliable QoS and optimized performances even under worst radio propagation conditions. The extension to the original functionality, consisting of the Link ID TLV, is considered by this MIB. " REVISION "201502170000Z" DESCRIPTION "Initial version 01.00.00. " ::= { siaeMib 93 } ---------------------------------------------------------------------------------- -- Textual Conventions ---------------------------------------------------------------------------------- MabBwCalculationMethod ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This Textual Convention describes the method of calculation of the radio bandwitdh (or the throughput of an interface): - average: Average Tx BW value across the observation interval - min: Minimum Tx BW value across the observation interval - max: Maximum Tx BW value across the observation interval " SYNTAX INTEGER { average (1), min (2), max (3) } MabPduCompliance ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This Textual Convention describes the compliance of the MAB PDU sent by a MAB PDU sender: - stdMcmCompliant: PDU format is compliant with [1] - extMcmCompliant: PDU format is compliant with [2] - ituG8013Compliant: PDU format is compliant with [4] Since [3] and [4] are a draft edition at the time when this MIB is being written, the value ituG8013Compliant(3) is defined for future use. " REFERENCE "[1] - MW CAPACITY MANAGEMENT (MCM) - FUNCTIONAL DESCRIPTION This document provides a description of the MW Capacity Management (MCM) feature developed by SIAE MICROELETTRONICA and Cisco. [2] - E-OAM Extensions for Microwave Adaptive Modulation Cisco Document Number EDCS-997459 [3] - Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent, 5 December 2014) [4] - Draft Amendment 1 to Recommendation ITU-T G.8013/Y.1731(2013) (for Consent, 5 December 2014) " SYNTAX INTEGER { stdMcmCompliant (1), extMcmCompliant (2), ituG8013Compliant (3) } MabSenderOption ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This Textual Convention describes the supported option of a MAB PDU sender: - enableAlways: Enable periodic PDU sending even if the current bandwidth is equal to the nominal bandwidth. - enableSignalFail: PDU are transmitted periodically when the link fails in the tranmit direction. If the NE usually sends PDUs also when the radio bandwitdh (or the throughput of an interface) is null, this option has no effect. " REFERENCE "[3] - Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent, 5 December 2014) " SYNTAX BITS { enableAlways (0), enableSignalFail (1) } ---------------------------------------------------------------------------------- -- MSP GROUP ---------------------------------------------------------------------------------- ------ Beginning -------------------------------------------------------------- mabMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. " ::= { mabMib 1} ------- Begin of mabSensorTable -- mabSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF MabSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with MAB sensors entries. Each sensor is associated to a interface, usually an interface with the physical layer consisting of a radio link, and comapares the current bandwidth (throughput) with the nominal one. When nominal and current bandwidth doesn't match to PDU senders associated with a sensor is required to send a MAB PDU every observation time. " ::= { mabMib 2 } mabSensorEntry OBJECT-TYPE SYNTAX MabSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the mabSensorTable. " INDEX { mabSensorIndex } ::= { mabSensorTable 1 } MabSensorEntry ::= SEQUENCE { mabSensorIndex Integer32, mabSensorRowStatus RowStatus, mabSensorAdminStatus INTEGER, mabSensorIfIndex InterfaceIndex, mabSensorLinkId Integer32, mabSensorBwMode MabBwCalculationMethod, mabSensorHoldoffTime Integer32, mabSensorObservationTime Integer32, mabSensorFastTime Integer32, mabSensorFastCount Integer32 } mabSensorIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the MAB sensor inside the Network Element. " ::= { mabSensorEntry 1 } mabSensorRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this MAB sensor entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: mabSensorIfIndex must be set to a valid ifIndex number. Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When set to notInService changes may be made to mabSensorIfIndex. Other objects can be changed when mabSensorRowStatus is set to active. A sensor can not be deleted if there is any MAB PDU sender associated with it. " ::= { mabSensorEntry 2 } mabSensorAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Administative status of the MAB sensor. The value down(1) turn off all MAB advisers associated with this sensor. " DEFVAL { down } ::= { mabSensorEntry 3 } mabSensorIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This object accepts a greater than zero value to identify an interface in ifTable. The throughput of the selected interface is monitored and notified to all MAB PDU sender associated with this sensor. " ::= { mabSensorEntry 4 } mabSensorLinkId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object set the (radio) link identifier that will be inserted in the Link ID TLV of the MAB PDU. " ::= { mabSensorEntry 5 } mabSensorBwMode OBJECT-TYPE SYNTAX MabBwCalculationMethod MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the method of calculation of the current bandwidth. The value of this parameter is sent inside MAB PDUs. " DEFVAL { average } ::= { mabSensorEntry 6 } mabSensorHoldoffTime OBJECT-TYPE SYNTAX Integer32(10..60) MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the wait time (in seconds) for MAB protocol before sending packets if the current bandwidth (throughput) is lower than the nominal. " DEFVAL { 10 } ::= { mabSensorEntry 7 } mabSensorObservationTime OBJECT-TYPE SYNTAX Integer32(1|10|60) MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the observation time (in seconds) for MAB protocol during which calculate the minimum, maximum and average value of the current bandwidth (throughput). At the end of each period, a MAB PDU is sent by every MAB PDU sender associated with this sensor. " DEFVAL { 10 } ::= { mabSensorEntry 8 } mabSensorFastTime OBJECT-TYPE SYNTAX Integer32(1..59) MAX-ACCESS read-create STATUS current DESCRIPTION "This value is used in place of mabSensorObservationTime for the first mabSensorFastCount PDU packets sent by a MAB PDU sender. The value of mabSensorFastTime must be less than or equal to mabSensorObservationTime. " REFERENCE "Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent, 5 December 2014) - 8.1.18 BNM insert process " DEFVAL { 10 } ::= { mabSensorEntry 9 } mabSensorFastCount OBJECT-TYPE SYNTAX Integer32(0..60) MAX-ACCESS read-create STATUS current DESCRIPTION "This value specifies how many MAB PDU packets are sent every mabSensorFastTime before to use the standard observation time (mabSensorObservationTime). Zero means which quick sending of packets is disabled. " REFERENCE "Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent, 5 December 2014) - 8.1.18 BNM insert process " DEFVAL { 0 } ::= { mabSensorEntry 10 } -- ------- End of mabSensorTable ------- Begin of mabSensorStatusTable -- mabSensorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MabSensorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with the status of MAB sensor entries. For each row in mabSensorTable a row is created in this table. " ::= { mabMib 3 } mabSensorStatusEntry OBJECT-TYPE SYNTAX MabSensorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the mabSensorTable. " INDEX { mabSensorIndex } ::= { mabSensorStatusTable 1 } MabSensorStatusEntry ::= SEQUENCE { mabSensorNominalBw Integer32, mabSensorCurrentBw Integer32 } mabSensorNominalBw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the nominal bandwidth (throughput) of the interface selected by mabSensorIfIndex. " ::= { mabSensorStatusEntry 1 } mabSensorCurrentBw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the current bandwidth (throughput) of the interface selected by mabSensorIfIndex and calculated according to the method set in mabSensorBwMode. " ::= { mabSensorStatusEntry 2 } -- ------- End of mabSensorStatusTable ------- Begin of mabPduSenderTable -- mabPduSenderTable OBJECT-TYPE SYNTAX SEQUENCE OF MabPduSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with MAB PDU sender entries. Each PDU sender refers to an ifIndex in ifTable on which to send a PDU MAB and a sensor that triggers the sending. " ::= { mabMib 4 } mabPduSenderEntry OBJECT-TYPE SYNTAX MabPduSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the mabPduSenderTable. " INDEX { mabPduSenderIndex } ::= { mabPduSenderTable 1 } MabPduSenderEntry ::= SEQUENCE { mabPduSenderIndex Integer32, mabPduSenderRowStatus RowStatus, mabPduSenderAdminStatus INTEGER, mabPduSenderIfIndex InterfaceIndex, mabPduSenderSensorIndex Integer32, mabPduSenderVlanId Integer32, mabPduSenderPcp Integer32, mabPduSenderOamMaintLevel Integer32, mabPduSenderDAType INTEGER, mabPduSenderUnicastDA MacAddress, mabPduSenderOption MabSenderOption, mabPduSenderPduCompliance MabPduCompliance } mabPduSenderIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the MAB PDU sender inside the Network Element. " ::= { mabPduSenderEntry 1 } mabPduSenderRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this mabPduSender entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: mabPduSenderIfIndex must be set to a valid ifIndex number and mabPduSenderSensorIndex must be set to a valid MAB sensor, Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When set to notInService changes may be made to mabPduSenderIfIndex, mabPduSenderSensorIndex. Other objects can be changed when mabPduSenderRowStatus is set to active. " ::= { mabPduSenderEntry 2 } mabPduSenderAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Administative status of the MAB PDU sender. " DEFVAL { down } ::= { mabPduSenderEntry 3 } mabPduSenderIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This object accepts a greater than zero value to identify an interface in ifTable. MAB PDU is sent over this interface. " ::= { mabPduSenderEntry 4 } mabPduSenderSensorIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object associates a MAB sensor to this PDU sender. " ::= { mabPduSenderEntry 5 } mabPduSenderVlanId OBJECT-TYPE SYNTAX Integer32(0|1..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the VLAN identifier used to tag the MAB PDU. Zero means the PDU is not tagged. " DEFVAL { 0 } ::= { mabPduSenderEntry 6 } mabPduSenderPcp OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines packet priority written into the tag of the MAB PDU. " DEFVAL { 7 } ::= { mabPduSenderEntry 7 } mabPduSenderOamMaintLevel OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the OAM maintenance level of the MAB PDU. The multicast destination address of the PDU is according to the selected maintenance level: 01-80-C2-00-00-3x where x = Maintenance Level " DEFVAL { 0 } ::= { mabPduSenderEntry 8 } mabPduSenderDAType OBJECT-TYPE SYNTAX INTEGER { multicastDA(1), unicastDA (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the destination MAC address type of the PDU: - multicastDA(1): Multicast Class 1 Destination Address (DA) - unicastDA(2): Unicast Destination Address (DA) " DEFVAL { multicastDA } ::= { mabPduSenderEntry 9 } mabPduSenderUnicastDA OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the unuicast destination address of the PDU when mabPduSenderDAType is set to unicastDA(2). " DEFVAL { '000000000000'H } ::= { mabPduSenderEntry 10 } mabPduSenderOption OBJECT-TYPE SYNTAX MabSenderOption MAX-ACCESS read-create STATUS current DESCRIPTION "This object enable the option supported by the MAB PDU sender: - enableAlways: Enable periodic PDU sending even if the current bandwidth is equal to the nominal bandwidth. - enableSignalFail: PDU are transmitted periodically when the link fails in the tranmit direction. If the NE usually sends PDUs also when the radio bandwitdh (or the throughput of an interface) is null, this option has no effect. " -- DEFVAL { { } } ::= { mabPduSenderEntry 11 } mabPduSenderPduCompliance OBJECT-TYPE SYNTAX MabPduCompliance MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the compliance of the MAB PDU format. " DEFVAL { stdMcmCompliant } ::= { mabPduSenderEntry 12 } -- ------- End of mabPduSenderTable ------ End group ------------------------------------------------------------- END