-- ---------------------------------------------------------------------------- -- -- SIAE MICROELETTRONICA s.p.a. -- -- Via Michelangelo Buonarroti, 21 -- 20093 - Cologno Monzese -- Milano -- ITALY -- -- ---------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- SIAE-PMTXPWR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, Unsigned32 FROM SNMPv2-SMI DisplayString, RowStatus FROM SNMPv2-TC siaeMib FROM SIAE-TREE-MIB AlarmStatus, AlarmSeverityCode FROM SIAE-ALARM-MIB; pmTxPwr MODULE-IDENTITY LAST-UPDATED "201410070000Z" ORGANIZATION "SIAE MICROELETTRONICA spa" CONTACT-INFO "SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com " DESCRIPTION "Performance Monitoring on Transmitted (TX) RF Power. " REVISION "201410070000Z" DESCRIPTION "Changed MAX-ACCESS caluse of some object of pmTxPwrTpClassTable from read-write to read-create " REVISION "201402030000Z" DESCRIPTION "Improved description of pmTxPwrMibVersion " REVISION "201304160000Z" DESCRIPTION "Initial version 01.00.00 " ::= { siaeMib 13 } ---------------------------------------------------------------------------------- -- object identifier inside the module ---------------------------------------------------------------------------------- ---------------------------------------------------------------------------------- -- pmTxPwr (PERFORMANCE MONITORING TRANSMITTED POWER LEVEL) GROUP ---------------------------------------------------------------------------------- -- -- The following objects are used to manage the Transmitted Power Performance -- Monitoring function. -- ---------------------------------------------------------------------------------- ------ Beginning -------------------------------------------------------------- -- ------- The following table contains the records with the counters used to monitor ------- the Transmitted power of the radio. ------- Begin of pmTxPwrCounterTable -- pmTxPwrMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01." DEFVAL {1} ::= {pmTxPwr 1} pmTxPwrCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF PmTxPwrCounterRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with PmTxPwr records: one record for 1+0 configuration and two record for 1+1 configuration." ::= {pmTxPwr 2} pmTxPwrCounterRecord OBJECT-TYPE SYNTAX PmTxPwrCounterRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "PmTxPwrCounter record." INDEX {pmTxPwrBranchId, pmTxPwrCounterBlockId} ::= {pmTxPwrCounterTable 1} PmTxPwrCounterRecord ::= SEQUENCE { pmTxPwrBranchId Integer32, pmTxPwrCounterBlockId Integer32, pmTxPwrCounterBlockType INTEGER, pmTxPwrCounterBlockStatus INTEGER, pmTxPwrCounterTimeStamp Unsigned32, pmTxPwrTlts1Counter Counter32, pmTxPwrTlts2Counter Counter32, pmTxPwrTlts3Counter Counter32, pmTxPwrTlts4Counter Counter32, pmTxPwrTMMax Integer32, pmTxPwrTMMin Integer32, pmTxPwrAverageTxLevel Integer32 } pmTxPwrBranchId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Radio Branch" ::= {pmTxPwrCounterRecord 1} pmTxPwrCounterBlockId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before)." ::= {pmTxPwrCounterRecord 2} pmTxPwrCounterBlockType OBJECT-TYPE SYNTAX INTEGER { daily (1), fifteenMin (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the counter block." ::= {pmTxPwrCounterRecord 3} pmTxPwrCounterBlockStatus OBJECT-TYPE SYNTAX INTEGER { meaningless (1), meaningfull (2), incomplete (3), dummy (4), lost (5), restarted (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "block counter status." ::= {pmTxPwrCounterRecord 4} pmTxPwrCounterTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object is the time when the performance record is closed reported as the second number since 1-Gen-1970." ::= {pmTxPwrCounterRecord 5} pmTxPwrTlts1Counter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of seconds when the Transmitted power is greater than the threshold 1." ::= {pmTxPwrCounterRecord 6} pmTxPwrTlts2Counter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of seconds when the Transmitted power is greater than the threshold 2" ::= {pmTxPwrCounterRecord 7} pmTxPwrTlts3Counter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of seconds when the Transmitted power is greater than the threshold 3" ::= {pmTxPwrCounterRecord 8} pmTxPwrTlts4Counter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of seconds when the Transmitted power is greater than the threshold 4" ::= {pmTxPwrCounterRecord 9} pmTxPwrTMMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum Transmitted Power Level Tide Mark." ::= {pmTxPwrCounterRecord 10} pmTxPwrTMMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum Transmitted Power Level Tide Mark." ::= {pmTxPwrCounterRecord 11} pmTxPwrAverageTxLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Power Transmitted Level (Average value)" ::= { pmTxPwrCounterRecord 12} -- ------- End of pmTxPwrCounterTable -- ------- The following table contains the records used to manage the P.M. on both ------- radio branch and the threshold cross alarms ------- Begin of pmTxPwrTpClassTable -- pmTxPwrTpClassTable OBJECT-TYPE SYNTAX SEQUENCE OF PmTxPwrTpClassRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with PmTxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration." ::= {pmTxPwr 3} pmTxPwrTpClassRecord OBJECT-TYPE SYNTAX PmTxPwrTpClassRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "PmTxPwrTpClass record." INDEX {pmTxPwrTpClassBranchId} ::= {pmTxPwrTpClassTable 1} PmTxPwrTpClassRecord ::= SEQUENCE { pmTxPwrTpClassBranchId Integer32, pmTxPwrTpClassStartStop INTEGER, pmTxPwrTpClassLabel DisplayString, pmTxPwrTpClassTimeStamp Unsigned32, pmTxPwrTpClass15MTlts1Alarm AlarmStatus, pmTxPwrTpClass15MTlts2Alarm AlarmStatus, pmTxPwrTpClass15MTlts3Alarm AlarmStatus, pmTxPwrTpClass15MTlts4Alarm AlarmStatus, pmTxPwrTpClass24HTlts1Alarm AlarmStatus, pmTxPwrTpClass24HTlts2Alarm AlarmStatus, pmTxPwrTpClass24HTlts3Alarm AlarmStatus, pmTxPwrTpClass24HTlts4Alarm AlarmStatus, pmTxPwrTpClassTlt1Threshold INTEGER, pmTxPwrTpClassTlt2Threshold INTEGER, pmTxPwrTpClassTlt3Threshold INTEGER, pmTxPwrTpClassTlt4Threshold INTEGER, pmTxPwrTpClass15MTlts1Threshold Integer32, pmTxPwrTpClass15MTlts2Threshold Integer32, pmTxPwrTpClass15MTlts3Threshold Integer32, pmTxPwrTpClass15MTlts4Threshold Integer32, pmTxPwrTpClass24HTlts1Threshold Integer32, pmTxPwrTpClass24HTlts2Threshold Integer32, pmTxPwrTpClass24HTlts3Threshold Integer32, pmTxPwrTpClass24HTlts4Threshold Integer32, pmTxPwrTpClassRowStatus RowStatus } pmTxPwrTpClassBranchId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Radio Branch" ::= {pmTxPwrTpClassRecord 1} pmTxPwrTpClassStartStop OBJECT-TYPE SYNTAX INTEGER { start (1), stop (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to start and to stop the Perfomance Monitoring counter evaluation." ::= {pmTxPwrTpClassRecord 2} pmTxPwrTpClassLabel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string used to identify the Tp class: pmTxPwrTpClassBranchId = 1 label = Radio 1 pmTxPwrTpClassBranchId = 2 label = Radio 2." ::= {pmTxPwrTpClassRecord 3} pmTxPwrTpClassTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object is the time when the performance record is closed reported as the second number since 1/1/70." ::= {pmTxPwrTpClassRecord 4} pmTxPwrTpClass15MTlts1Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "15 minutes Tlts1 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 5} pmTxPwrTpClass15MTlts2Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "15 minutes Tlts2 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 6} pmTxPwrTpClass15MTlts3Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "15 minutes Tlts3 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 7} pmTxPwrTpClass15MTlts4Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "15 minutes Tlts4 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 8} pmTxPwrTpClass24HTlts1Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Daily Tlts1 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 9} pmTxPwrTpClass24HTlts2Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Daily Tlts2 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 10} pmTxPwrTpClass24HTlts3Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Daily Tlts3 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 11} pmTxPwrTpClass24HTlts4Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Daily Tlts4 threshold cross alarm with associated severity." ::= {pmTxPwrTpClassRecord 12} pmTxPwrTpClassTlt1Threshold OBJECT-TYPE SYNTAX INTEGER (-100..-20) MAX-ACCESS read-create STATUS current DESCRIPTION "Received Power Level Threshold 1 (dBm value); range -100 to -20" DEFVAL {-30} ::= {pmTxPwrTpClassRecord 13} pmTxPwrTpClassTlt2Threshold OBJECT-TYPE SYNTAX INTEGER (-100..-20) MAX-ACCESS read-create STATUS current DESCRIPTION "Received Power Level Threshold 2 (dBm value); range -100 to -20" DEFVAL {-40} ::= {pmTxPwrTpClassRecord 14} pmTxPwrTpClassTlt3Threshold OBJECT-TYPE SYNTAX INTEGER (-100..-20) MAX-ACCESS read-create STATUS current DESCRIPTION "Received Power Level Threshold 3 (dBm value); range -100 to -20" DEFVAL {-50} ::= {pmTxPwrTpClassRecord 15} pmTxPwrTpClassTlt4Threshold OBJECT-TYPE SYNTAX INTEGER (-100..-20) MAX-ACCESS read-create STATUS current DESCRIPTION "Received Power Level Threshold 4 (dBm value); range -100 to -20" DEFVAL {-60} ::= {pmTxPwrTpClassRecord 16} pmTxPwrTpClass15MTlts1Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 17} pmTxPwrTpClass15MTlts2Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 18} pmTxPwrTpClass15MTlts3Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 19} pmTxPwrTpClass15MTlts4Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 20} pmTxPwrTpClass24HTlts1Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 21} pmTxPwrTpClass24HTlts2Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 22} pmTxPwrTpClass24HTlts3Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 23} pmTxPwrTpClass24HTlts4Threshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm (zero value disables the alarm)." DEFVAL {0} ::= {pmTxPwrTpClassRecord 24} pmTxPwrTpClassRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this row of pmTxPwrTpClass. " ::= {pmTxPwrTpClassRecord 25} -- ------- End of pmTxPwrTpClassTable -- -- MAINTENANCE TABLE -- ------- Begin of PmTxPwrTpMaintRecord -- pmTxPwrTpMaintTable OBJECT-TYPE SYNTAX SEQUENCE OF PmTxPwrTpMaintRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmTxPwrTpClassTable" ::= {pmTxPwr 4} pmTxPwrTpMaintRecord OBJECT-TYPE SYNTAX PmTxPwrTpMaintRecord MAX-ACCESS not-accessible STATUS current DESCRIPTION "PmG828 Termination Point Maintenance record." INDEX {pmTxPwrTpClassBranchId} ::= {pmTxPwrTpMaintTable 1} PmTxPwrTpMaintRecord ::= SEQUENCE { pmTxPwrTpMaintCounterClear INTEGER, pmTxPwrTpMaintAlarmClear INTEGER } pmTxPwrTpMaintCounterClear OBJECT-TYPE SYNTAX INTEGER { notActive (0), clear (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to clear the Perfomance Monitoring counters." ::= {pmTxPwrTpMaintRecord 1} pmTxPwrTpMaintAlarmClear OBJECT-TYPE SYNTAX INTEGER { notActive (0), clear (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to clear the Perfomance Monitoring threshold cross alarms." ::= {pmTxPwrTpMaintRecord 2} -- ------- End of PmTxPwrTpMaintRecord -- ------- The following objects are common to all radio branches. -- pmTxPwrTpClass15MTltsAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the pmTxPwrTpClass15MTltsAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {pmTxPwr 5} pmTxPwrTpClass24HTltsAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the pmTxPwrTpClass24HTltsAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {pmTxPwr 6} ------ End group ----------------------------------------------------------------- END