-- ---------------------------------------------------------------------------- -- -- SIAE MICROELETTRONICA s.p.a. -- -- Via Michelangelo Buonarroti, 21 -- 20093 - Cologno Monzese -- Milano -- ITALY -- -- ---------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- SIAE-RADIO-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32 FROM SNMPv2-SMI InterfaceIndexOrZero FROM IF-MIB TEXTUAL-CONVENTION, DisplayString, RowStatus, StorageType FROM SNMPv2-TC siaeMib FROM SIAE-TREE-MIB AlarmStatus, AlarmSeverityCode, alarmTrap FROM SIAE-ALARM-MIB equipIpSnmpAgentAddress FROM SIAE-EQUIP-MIB; radioSystem MODULE-IDENTITY LAST-UPDATED "201607140000Z" ORGANIZATION "SIAE MICROELETTRONICA spa" CONTACT-INFO "SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: help@siaemic.com " DESCRIPTION "Radio System MIB. " REVISION "201607140000Z" DESCRIPTION "MIB version 01.00.05 - added radioXpd in radioStatusTable - deprecated linkXpd in linkStatusTable " REVISION "201602290000Z" DESCRIPTION "MIB version 01.00.04 - Added linkXpd to linkStatusTable - changed MAX-ACCESS clause of linkChRadioSettingsIdx from read-only to read-create - Fixed DESCRIPTION of linkSettingsTable " REVISION "201509150000Z" DESCRIPTION "Fixed DESCRIPTION of radioTxChannelSpacing " REVISION "201506180000Z" DESCRIPTION "MIB version 01.00.03 - Added linkConfigurationInProgress and linkConfigurationInProgressTrapNotification - Added radio radioRxBerThresholdTable - Added fadeMarginMeasure - Deprecated linkFadeMarginMeasure - Added table radioLoopCapabilityTable - Added table sspTable - Added table stm1BulkSettingsTable - Added table linkE1vsSTM1CapacityTable - Deprecated linkAcmMaxTDMCapacity - Deprecated linkTfcTable, linkProTable and linkProMaintTable. - Added linkTfcV2Table, linkProV2Table and linkProMaintV2Table in order to replace deprecated tables. - Added channelSpacingSelection " REVISION "201503230000Z" DESCRIPTION "Removed alarmTrapNumber from TRAPs and IMPORTS. " REVISION "201411050000Z" DESCRIPTION "MIB version 01.00.02 Changes for support of modulation 4096QAM: - DESCRIPTION of linkBandwidthAndModulation - ModulationMap TEXTUAL-CONVENTION - BitsPerSymbol TEXTUAL-CONVENTION Changes for support of channel spacing 60MHz and 80MHz: - DESCRIPTION of linkBandwidthAndModulation - ChannelSpacing TEXTUAL-CONVENTION " REVISION "201409160000Z" DESCRIPTION "MIB version 01.00.01 - Added combinedRadioCapabilitiesTable, combinedRadioFrequencyTable, combinedRadioDuplexFrequencyTable and combinedRadioPowerScalingTable - Declared deprecated linkCapabilitiesTable, linkFrequencyTable, linkDuplexFrequencyTable, linkAcmPowerScaling, linkAcmAtpcRxPowerScaling and linkAcmPowerRange. - Added linkNotMatchingRadiosAlarm and linkNotMatchingRadiosAlarmSeverityCode " REVISION "201404010000Z" DESCRIPTION "Initial version 01.00.00. " ::= { siaeMib 80 } ---------------------------------------------------------------------------------- -- Textual Conventions ---------------------------------------------------------------------------------- ChannelSpacing ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This TC describes a data type which identifies a RF channel spacing. " SYNTAX INTEGER { -- ETSI bw3M5Hz (0), bw7Mhz (1), bw14MHz (2), bw28MHz (3), bw40MHz (5), bw56MHz (4), bw112MHz (6), bw250Mhz (7), bw500Mhz (8), bw750Mhz (9), bw1000Mhz (10), -- FCC bw10Mhz (11), bw20Mhz (12), bw30Mhz (13), bw50Mhz (14), bw60Mhz (15), bw80Mhz (16) } ModulationMap ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used as the syntax of the radioBranchModulationMap and radioBranchRefModulationMap objects. " SYNTAX BITS { modBPSK (0), mod4QAM (1), mod8PSK (2), mod16QAM (3), mod32QAM (4), mod64QAM (5), mod128QAM (6), mod256QAM (7), mod512QAM (8), mod1024QAM (9), mod2048QAM (10), mod4096QAM (11) } ConfigMismatchReason ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used to specify the cause of Config Mismatch Alarm, that is the mismatch between the radio link capability and the current local and remote configuration. - securityMismatch(0) Copyright violation - frequencyFailMismatch(1) Configured frequency is out of Filter-Bandwidth - frequencyAlertMismatch(2) Configured frequency across Filter-Bandwidth - ptxMismatch(3) Tx power configured incongruent with RF Tx power limits - channelSpacingAndModulationMismatch(4) Bandwidth and/or modulation configured is invalid (RF doesn't support it) - remoteConfigurationMismatch(5) Incongruence between the couple of Terminal Radio Unit (TRU) in the link: - Frequency Incongruent (Freq) - Reference Bandwidth and Modulation incongruent - Acm-Tx map in congruent with remote Acm-Rx map - acmMismatch(6) Obsolete (no longer used) - profileSetMismatch(7) The selected profile set is not supported by the TRU " SYNTAX BITS { securityMismatch(0), frequencyFailMismatch(1), frequencyAlertMismatch(2), ptxMismatch(3), channelSpacingAndModulationMismatch(4), remoteConfigurationMismatch(5), acmMismatch(6), profileSetMismatch(7) } RadioCapability ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used as the syntax of the radioBranchKeyFeatures objects. " SYNTAX BITS { reserved (0), trafficSquelch (1), baseBandLoop (2), maxPower (3), carrierOnly (4), iQLoop (5), rfLoopGivenMod (6), -- only at a given modulation rfLoopAnyMod (7) -- at any modulation } BitsPerSymbol ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "his TC describes a data type which identifies a RF channel spacing. " SYNTAX INTEGER { bpsBPSK (1), bps4QAM (2), bps8PSK (3), bps16QAM (4), bps32QAM (5), bps64QAM (6), bps128QAM (7), bps256QAM (8), bps512QAM (9), bps1024QAM (10), bps2048QAM (11), bps4096QAM (12) } Stm1IndexOrZero ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "This textual convention permits the additional value of zero to an stm1Index in stm1Table. The value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where stm-1 was unknown, or when none or all stm-1s need to be referenced." SYNTAX Integer32 (0..2147483647) ---------------------------------------------------------------------------------- -- radioSystem GROUP ---------------------------------------------------------------------------------- -- -- This group contains all the objects that are specific of the radio system -- ---------------------------------------------------------------------------------- ------ Beginning -------------------------------------------------------------- radioSystemMibVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01." ::= {radioSystem 1} ------- Begin of radioTable -- radioTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of radio interface entries. This table is useful to show the manager all the available radio interfaces on the equipment. Moreover it is a reference for Performance Monitoring (PWR and G828). " ::= {radioSystem 2} radioEntry OBJECT-TYPE SYNTAX RadioEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular radio interface. " INDEX {radioIndex} ::= {radioTable 1} RadioEntry ::= SEQUENCE { radioIndex Integer32, radioLabel DisplayString, radioType INTEGER, radioIfIndex InterfaceIndexOrZero, radioStorageType StorageType } radioIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each radio interface. It is recommended that values are assigned contiguously starting from 1. " ::= {radioEntry 1} radioLabel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the radio interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware/software. " ::= {radioEntry 2} radioType OBJECT-TYPE SYNTAX INTEGER { other(1), analogRadio(2), -- analogic radio -- digitalRadio(3), -- digital radio -- xpicRadio(4) -- xpic radio -- } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of interface. " ::= {radioEntry 3} radioIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines a greater than zero value to identify an interface in ifTable or a zero value if ifTable is not supported. " ::= {radioEntry 4} radioStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-only STATUS current DESCRIPTION "The storage type of this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row. " ::= {radioEntry 5} -- ------- End of radioTable ------- Begin of xpicTable -- xpicTable OBJECT-TYPE SYNTAX SEQUENCE OF XpicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of xpic radio interface entries. If a manager wants to make an xpic link, it should only add a particular xpic radio interface to an xpic link. " ::= {radioSystem 3} xpicEntry OBJECT-TYPE SYNTAX XpicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular xpic radio interface. " INDEX {xpicIndex} ::= {xpicTable 1} XpicEntry ::= SEQUENCE { xpicIndex Integer32, xpicRadioIdx Integer32, xpicRowstatus RowStatus } xpicIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each xpic radio interface. It is recommended that values are assigned contiguously starting from 1. " ::= {xpicEntry 1} xpicRadioIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index of xpic radio interface, corresponding to an available xpic radio interface in radioTable. " ::= {xpicEntry 2} xpicRowstatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this conceptual row in xpicTable. " ::= {xpicEntry 3} -- ------- End of xpicTable ------- Begin of xpicChTable -- xpicChTable OBJECT-TYPE SYNTAX SEQUENCE OF XpicChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of xpic channel entries. This table maps each xpic radio in respective xpic radio interface. " ::= {radioSystem 4} xpicChEntry OBJECT-TYPE SYNTAX XpicChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular xpic channel. It defines radio interface and polarization for a given xpic channel. " INDEX {xpicIndex, xpicChPolIndex} ::= {xpicChTable 1} XpicChEntry ::= SEQUENCE { xpicChPolIndex Integer32, xpicChRadioIdx Integer32, xpicChRowstatus RowStatus } xpicChPolIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the xpic radio polarization. " ::= {xpicChEntry 1} xpicChRadioIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Xpic radio interface, corresponding to a radio interface in radioTable, used to make up the given xpic radio interface. " ::= {xpicChEntry 2} xpicChRowstatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this conceptual row in xpicChTable. " ::= {xpicChEntry 3} -- ------- End of xpicChTable linkAvailableIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows an index which is available for creation of a new link in the system. It shows the smallest available index. Any attempt to create a link with a different index results in a failure. " ::= {radioSystem 5} ------- Begin of linkTable -- linkTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of link entries. " ::= {radioSystem 6} linkEntry OBJECT-TYPE SYNTAX LinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular link. " INDEX {linkIndex} ::= {linkTable 1} LinkEntry ::= SEQUENCE { linkIndex Integer32, linkType INTEGER, linkLabel DisplayString, linkIfIndex InterfaceIndexOrZero, linkRowstatus RowStatus } linkIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each link. Manager must use the first available index, suggested by linkAvailableIndex. " ::= {linkEntry 1} linkType OBJECT-TYPE SYNTAX INTEGER { radio1p0(1), -- 1+0 radio1p1HS(2), -- 1+1 Hot Standby radio1p1FD(3), -- 1+1 Frequency Diversity radio2p0Xpic(4), -- 2+0 XPIC radio2p2XpicHS(5), -- 2+2 XPIC Hot Standby radio2p2XpicFD(6), -- 2+2 XPIC Frequency Diversity radioNp1(7) -- N+1 } MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies link type. Supported link types are: single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC, 2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1. " DEFVAL {radio1p0} ::= {linkEntry 2} linkLabel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "A textual string containing information about the link. This string should give more details about link specific parameters. " DEFVAL {""} ::= {linkEntry 3} linkIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines a greater than zero value to identify a link in ifTable or a zero value if ifTable is not supported. " DEFVAL {0} ::= {linkEntry 4} linkRowstatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this row of linkTable. This object is used to manage the creation and deletion of conceptual rows in linkTable. To create a row in this table, a manager should set rowstatus to createAndWait(5) and choose a link type. Respective entries in linkSettingsTable, linkStatusTable and tdmSettingsTable will be created by agent.In case of protection links proper entries in linkProtectionTable will be also created. Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The contents of linkSettingsTable and radioSettingsTable can be changed only if this object is notInService(2). " ::= {linkEntry 5} -- ------- End of linkTable ------- Begin of linkChTable -- linkChTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of link channel entries. " ::= {radioSystem 7} linkChEntry OBJECT-TYPE SYNTAX LinkChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular link channel. " INDEX {linkIndex, linkChIndex} ::= {linkChTable 1} LinkChEntry ::= SEQUENCE { linkChIndex Integer32, linkChRadioIdx Integer32, linkChRadioSettingsIdx Integer32, linkChRowstatus RowStatus } linkChIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Link Channel Index. " ::= {linkChEntry 1} linkChRadioIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Radio channel index that corresponds to an available radio interface in radioTable. " ::= {linkChEntry 2} linkChRadioSettingsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Radio Settings Index. This object is a foreign key for a corresponding radioSettingsTable entry, which is automatically created by agent. " DEFVAL {0} ::= {linkChEntry 3} linkChRowstatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this row of linkChTable. This object is used to manage the creation and deletion of conceptual rows in linkChTable. To create a row in this table, a manager should set rowstatus to createAndWait(5). Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The content of radioSettingsTable can be changed only if this object is notInService(2). " ::= {linkChEntry 4} -- ------- End of linkChTable ------- Begin of linkSettingsTable -- linkSettingsTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with link settings entries. This table contains all parameters of a radio frequency link. The content of this table can be changed by a manager if linkRowStatus is notInService(2)." ::= {radioSystem 8} linkSettingsEntry OBJECT-TYPE SYNTAX LinkSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio link entry" INDEX {linkIndex} ::= {linkSettingsTable 1} LinkSettingsEntry ::= SEQUENCE { linkBandwidthAndModulation Integer32, linkAcmEngineEnable INTEGER, linkTxUpperProfile INTEGER, linkTxLowerProfile INTEGER, linkId INTEGER, linkTxPwrThresh INTEGER, linkRxPwrThresh INTEGER, linkSynchSetupProtocolEnable INTEGER, linkProfilesSetSelection INTEGER, linkXpicControlProcedure INTEGER } linkBandwidthAndModulation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Link Modulation and Bandwidth (channel spacing). The value of this object value is computed by: 65536*modulation+bandwidth where bandwidth selection is: 0 = 3.5Mhz 1 = 7MHz 2 = 14MHz 3 = 28MHz 4 = 56MHz 5 = 10MHz 6 = 20MHz 7 = 30MHz 8 = 40MHz 9 = 50MHz 10 = 112Mhz 11 = 250Mhz 12 = 500Mhz 13 = 750Mhz 14 = 1Ghz 15 = 60MHz 16 = 80MHz and modulation is in bit-per-symbol: 1 = BPSK 2 = 4QAM 3 = 8PSK 4 = 16QAM 5 = 32QAM 6 = 64QAM 7 = 128QAM 8 = 256QAM 9 = 512QAM 10 = 1024QAM 11 = 2048QAM. 12 = 4096QAM. Examples: 250Mhz-4QAM (131083), 500Mhz-4QAM (131084), 250Mhz-16QAM (262155), 500Mhz-64QAM (393228). Note: 0 bit-per-symbol is not possible, so value 0 is used for BandwidthAndModulation unassigned." ::= {linkSettingsEntry 1} linkAcmEngineEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to enable/disable the ACM engine" DEFVAL { disable } ::= {linkSettingsEntry 2} linkTxUpperProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled." ::= {linkSettingsEntry 3} linkTxLowerProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled." ::= {linkSettingsEntry 4} linkId OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Link Identification (value 0..255)" DEFVAL {0} ::= {linkSettingsEntry 5} linkTxPwrThresh OBJECT-TYPE SYNTAX INTEGER (3..15) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold (value +3 , +15 dB) relative to nominal value of the TX power below wich the related alarm is set." DEFVAL {3} ::= {linkSettingsEntry 6} linkRxPwrThresh OBJECT-TYPE SYNTAX INTEGER (-99..-40) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold (value -40 , -99 dBm) for RX power below wich the related alarm is set." DEFVAL {-70} ::= {linkSettingsEntry 7} linkSynchSetupProtocolEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Synchronization Setup Protocol (SSP) control" DEFVAL {disable} ::= {linkSettingsEntry 8} linkProfilesSetSelection OBJECT-TYPE SYNTAX INTEGER { highThroughput (1), highGain (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported. " DEFVAL {highThroughput} ::= {linkSettingsEntry 9} linkXpicControlProcedure OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Set by manager to enable\disable XPIC alarm control procedure. Only for XPIC configurations." DEFVAL { enable } ::= {linkSettingsEntry 10} -- ------- End of linkSettingsTable ------- Begin of radioSettingsTable -- radioSettingsTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with radio settings entries. This table contains all parameters of a radio terminal. The content of this table can be changed only linkRowStatus is notInService(2)" ::= {radioSystem 9} radioSettingsEntry OBJECT-TYPE SYNTAX RadioSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio terminal entry" INDEX {radioSettingsIndex} ::= {radioSettingsTable 1} RadioSettingsEntry ::= SEQUENCE { radioSettingsIndex Integer32, radioSettingsRowStatus RowStatus, radioSettingsLabel DisplayString, radioTxFrequency INTEGER, radioDuplexFrequency INTEGER, radioTxAttenuation INTEGER, radioAtpcManual INTEGER, radioAtpcPwrHigh Integer32, radioAtpcPwrLow Integer32, radioAtpcRange Integer32, radioFreqTableSelection ChannelSpacing } radioSettingsIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Radio settings index. " ::= {radioSettingsEntry 1} radioSettingsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this row. " ::= {radioSettingsEntry 2} radioSettingsLabel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the radio interface. " ::= {radioSettingsEntry 3} radioTxFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Transmitted frequency in KHz. Null value means invalid frequency." DEFVAL {0} ::= {radioSettingsEntry 4} radioDuplexFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Value of duplex frequency in KHz. -2 means not set." DEFVAL {-2} ::= {radioSettingsEntry 5} radioTxAttenuation OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Transmitter attenuation relative to nominal power (dBm)." ::= {radioSettingsEntry 6} radioAtpcManual OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enables/disables Atpc Manual operation." DEFVAL {disable} ::= {radioSettingsEntry 7} radioAtpcPwrHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ATPC Control - Local Rx Power High (dBm range -30 to -80) -." DEFVAL {-40} ::= {radioSettingsEntry 8} radioAtpcPwrLow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ATPC Control - Local Rx Power Low (dBm range -30 to -80) -." DEFVAL {-60} ::= {radioSettingsEntry 9} radioAtpcRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the range of the ATPC regulation (expressed in dB) with respect to the current value of maximum Tx output, that is intended as the upper limit of the range. A null value means no limit: the lower limit of the range is equal to minimum Ptx." DEFVAL {0} ::= {radioSettingsEntry 10} radioFreqTableSelection OBJECT-TYPE SYNTAX ChannelSpacing MAX-ACCESS read-create STATUS current DESCRIPTION "RadioFrequencyTable key (channel spacing & modulation) selection." ::= {radioSettingsEntry 11} -- ------- End of radioSettingsTable ------- Begin of tdmSettingsTable -- tdmSettingsTable OBJECT-TYPE SYNTAX SEQUENCE OF TdmSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with tdm settings entries. " ::= {radioSystem 10} tdmSettingsEntry OBJECT-TYPE SYNTAX TdmSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing tdm parameters for a particular link. " INDEX {linkIndex, tdmPolIndex} ::= {tdmSettingsTable 1} TdmSettingsEntry ::= SEQUENCE { tdmPolIndex Integer32, tdmE1Channel Integer32, tdmE1Framer INTEGER } tdmPolIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Polarization index. " ::= {tdmSettingsEntry 1} tdmE1Channel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s). " DEFVAL {0} ::= {tdmSettingsEntry 2} tdmE1Framer OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to attach the framer to a given E1. " DEFVAL {disable} ::= {tdmSettingsEntry 3} -- ------- End of tdmSettingsTable ------- Begin of radioCapabilitiesTable -- radioCapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with RadioCapabilities entries: there is an entry for each radioTable rows." ::= {radioSystem 11} radioCapabilitiesEntry OBJECT-TYPE SYNTAX RadioCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RadioCapabilities entry." INDEX {radioIndex} ::= {radioCapabilitiesTable 1} RadioCapabilitiesEntry ::= SEQUENCE { radioCapabilitiesCapability RadioCapability, radioCapabilitiesTxMinFrequency Integer32, radioCapabilitiesTxMaxFrequency Integer32, radioCapabilitiesStepFrequency Integer32, radioCapabilitiesMinPtxNominalValue Integer32, radioCapabilitiesMaxPtxNominalValue Integer32, radioCapabilitiesExtendedMinPwr Integer32 } radioCapabilitiesCapability OBJECT-TYPE SYNTAX RadioCapability MAX-ACCESS read-only STATUS current DESCRIPTION "Bit map to describe the radio features." ::= {radioCapabilitiesEntry 1} radioCapabilitiesTxMinFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum of available channel frequency in KHz." ::= {radioCapabilitiesEntry 2} radioCapabilitiesTxMaxFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum of available channel frequency in KHz." ::= {radioCapabilitiesEntry 3} radioCapabilitiesStepFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum frequency step in KHz." ::= {radioCapabilitiesEntry 4} radioCapabilitiesMinPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum nominal Ptx in dBm." ::= {radioCapabilitiesEntry 5} radioCapabilitiesMaxPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum nominal Ptx in dBm." ::= {radioCapabilitiesEntry 6} radioCapabilitiesExtendedMinPwr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum extended Ptx power for fade margin." ::= {radioCapabilitiesEntry 7} -- ------- End of radioCapabilitiesTable ------- Begin of radioStatusTable -- radioStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with RadioStatus records: one record for 1+0 configuration and two record for 1+1 configuration." ::= {radioSystem 12} radioStatusEntry OBJECT-TYPE SYNTAX RadioStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RadioStatus record." INDEX {radioIndex} ::= {radioStatusTable 1} RadioStatusEntry ::= SEQUENCE { radioCurrentDuplexFrequency Integer32, radioTxChannelSpacing Integer32, radioPrx Integer32, radioPtx Integer32, radioNormalizedMse Integer32, radioRxActiveStatus INTEGER, radioTxActiveStatus INTEGER, radioCableOpenAlarm AlarmStatus, radioCableShortAlarm AlarmStatus, radioInvalidFrequencyAlarm AlarmStatus, radioBaseBandRxAlarm AlarmStatus, radioModulatorFailAlarm AlarmStatus, radioDemodulatorFailAlarm AlarmStatus, radioRxPowerLowAlarm AlarmStatus, radioTxPowerLowAlarm AlarmStatus, radioRemDemodulatorFailAlarm AlarmStatus, radioVcoFailAlarm AlarmStatus, radioRxIFAgcAlarm AlarmStatus, radioTxIFAgcAlarm AlarmStatus, radioIduOduCommunicationAlarm AlarmStatus, radioOduIduCommunicationAlarm AlarmStatus, radioLocalOduAlarmSynthesis AlarmStatus, radioRemoteOduAlarmSynthesis AlarmStatus, radioConfigMismatchAlarm AlarmStatus, radioConfigAlarmReason ConfigMismatchReason, radioRxQualityLowAlarm AlarmStatus, radioRxQualityWarningAlarm AlarmStatus, radioXpd Integer32 } radioCurrentDuplexFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Spacing between transmitted and received frequency in KHz." ::= {radioStatusEntry 1} radioTxChannelSpacing OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Half of transmitted signal channel spacing in KHz." ::= {radioStatusEntry 2} radioPrx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Received power level (dBm)." ::= {radioStatusEntry 3} radioPtx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted power level (dBm)." ::= {radioStatusEntry 4} radioNormalizedMse OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Normalized MSE (Mean Squared Error) is an indicator of the Signal to Noise (S/N) ratio. It's in 0.1 dB steps" ::= {radioStatusEntry 5} radioRxActiveStatus OBJECT-TYPE SYNTAX INTEGER { cleared (1), active (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiver Active status with associated Severity In 1+1 Hot Standby radio system, only one RX is active. RXs are active in other configurations of the radio system. " ::= {radioStatusEntry 6} radioTxActiveStatus OBJECT-TYPE SYNTAX INTEGER { cleared (1), active (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter Active status with associated Severity. In 1+1 Hot Standby radio system, only one TX is active. TXs are active in other configurations of the radio system. " ::= {radioStatusEntry 7} radioCableOpenAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cable connnecting ODU is open: alarm status with associated severity. " ::= {radioStatusEntry 8} radioCableShortAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cable connnecting ODU is in short-circuit: alarm status with associated severity. " ::= {radioStatusEntry 9} radioInvalidFrequencyAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Invalid frequency alarm with associated severity." ::= {radioStatusEntry 10} radioBaseBandRxAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Base Band Rx alarm status with associated severity." ::= {radioStatusEntry 11} radioModulatorFailAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Modulator Fail Alarm status with associated severity." ::= {radioStatusEntry 12} radioDemodulatorFailAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Demodulator Fail Alarm status with associated severity." ::= {radioStatusEntry 13} radioRxPowerLowAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Receiver power low alarm status with associated severity." ::= {radioStatusEntry 14} radioTxPowerLowAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter power low alarm status with associated severity." ::= {radioStatusEntry 15} radioRemDemodulatorFailAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Demodulator Fail Alarm status with associated severity." ::= {radioStatusEntry 16} radioVcoFailAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RT VCO fail alarm status with associated severity." ::= {radioStatusEntry 17} radioRxIFAgcAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RT Rx IF AGC fail alarm status with associated severity." ::= {radioStatusEntry 18} radioTxIFAgcAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RT Tx IF AGC fail alarm status with associated severity." ::= {radioStatusEntry 19} radioIduOduCommunicationAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Communication from IDU towards ODU is down" ::= {radioStatusEntry 20} radioOduIduCommunicationAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Communication from ODU towards IDU is down" ::= {radioStatusEntry 21} radioLocalOduAlarmSynthesis OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Local ODU alarm synthesis with associated severity." ::= {radioStatusEntry 22} radioRemoteOduAlarmSynthesis OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Local ODU alarm synthesis alarm status with associated severity." ::= {radioStatusEntry 23} radioConfigMismatchAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Config Mismatch alarm status with associated severity and related map." ::= {radioStatusEntry 24} radioConfigAlarmReason OBJECT-TYPE SYNTAX ConfigMismatchReason MAX-ACCESS read-only STATUS current DESCRIPTION "Bit map to describe the Config Mismatch Alarm" -- DEFVAL { { } } ::= {radioStatusEntry 25} radioRxQualityLowAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "High BER Alarm status with associated severity." ::= {radioStatusEntry 26} radioRxQualityWarningAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The RX signal is close to cause errors on payload." ::= {radioStatusEntry 27} radioXpd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one. " ::= {radioStatusEntry 28} -- ------- End of radioStatusTable -- -- MAINTENANCE TABLE -- ------- Begin of radioMaintTable -- radioMaintTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with Command for maintenance of radio branch. Objects in this table is not persistent. An Instance of this table is created on creation of radioBranchEntry" ::= {radioSystem 13} radioMaintEntry OBJECT-TYPE SYNTAX RadioMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio branch Maintenance record." INDEX {radioIndex} ::= {radioMaintTable 1} RadioMaintEntry ::= SEQUENCE { radioTxStatus INTEGER, radioCarrierOnly INTEGER, radioLoop INTEGER, radioRFLoopTestResult INTEGER, radioRFLoopTestPercTime INTEGER, radioRtPsuOff INTEGER, radioLom INTEGER, radioXpic INTEGER } radioTxStatus OBJECT-TYPE SYNTAX INTEGER { transmitterOff (1), transmitterOn (2), permanentOff (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transmitter status control. The value transmitterOff(1) is related to a manual operation. The value permanentOff(3) is persistent across restart. " DEFVAL {transmitterOn} ::= {radioMaintEntry 1} radioCarrierOnly OBJECT-TYPE SYNTAX INTEGER { carrierOnlyOff (1), carrierOnlyOn (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Carrier only transmission control." DEFVAL {carrierOnlyOff} ::= {radioMaintEntry 2} radioLoop OBJECT-TYPE SYNTAX INTEGER { loopOff (1), rfLoop (2), iqLoop (3), baseBandLoop (4), rfLoopAtFixedMod (6), baseBandLoopEthSquelch (7), rfLoopAtFixedModEthSquelch(8), iqloopEthSquelch (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the Radio Branch loops." DEFVAL {loopOff} ::= {radioMaintEntry 3} radioRFLoopTestResult OBJECT-TYPE SYNTAX INTEGER { testNone (0), testRunning (1), testNotPossible (2), testPassed (3), testFail (4), testInterrupted (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Radio branch RT loop test result." DEFVAL {testNone} ::= {radioMaintEntry 4} radioRFLoopTestPercTime OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Radio branch RT loop test time percentage" ::= {radioMaintEntry 5} radioRtPsuOff OBJECT-TYPE SYNTAX INTEGER { rtPsuOff (1), rtPsuOn (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "It switches on/off the Rt power supply" DEFVAL {rtPsuOn} ::= {radioMaintEntry 6} radioLom OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to enable the IP packet forwarding towards Radio." DEFVAL {disable} ::= {radioMaintEntry 7} radioXpic OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable of the cross polarization interference cancellation of this radio. The value disable is tied to a manual operation (ManOpRecord). This object is applicable only if thiis radio belongs to a 2+0 XPIC or 2+2 XPIC link." ::= {radioMaintEntry 8} -- ------- End of radioMaintTable ------- Begin of radioFrequencyTable -- radioFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Availables channels for selected channel spacing and modulation (see leaf radioFreqTableSelection)." ::= {radioSystem 14} radioFreqTabEntry OBJECT-TYPE SYNTAX RadioFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RadioFreqTab record." INDEX {radioIndex, radioFreqChannelId} ::= {radioFrequencyTable 1} RadioFreqEntry ::= SEQUENCE { radioFreqChannelId Integer32, radioFreqChannelNum Integer32, radioFreqValue Integer32 } radioFreqChannelId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the table" ::= {radioFreqTabEntry 1} radioFreqChannelNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Available channel number." ::= {radioFreqTabEntry 2} radioFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency related to radioFreqChannelNum." ::= {radioFreqTabEntry 3} -- ------- End of radioFrequencyTable ------- Begin of radioDuplexFrequencyTable -- radioDuplexFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioDuplexFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency." ::= {radioSystem 15} radioDuplexFreqEntry OBJECT-TYPE SYNTAX RadioDuplexFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duplex Frequency entry. There is an entry for each available duplex frequency." INDEX {radioIndex, radioDuplexFreqId} ::= {radioDuplexFrequencyTable 1} RadioDuplexFreqEntry ::= SEQUENCE { radioDuplexFreqId Integer32, radioDuplexFreqValue Integer32 } radioDuplexFreqId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the table." ::= {radioDuplexFreqEntry 1} radioDuplexFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Duplex frequency in KHz." ::= {radioDuplexFreqEntry 2} -- ------- End of radioDuplexFrequencyTable ------- Begin of radioModulationTable -- radioModulationTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioModulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of modulations related to channel spacing." ::= {radioSystem 16} radioModulationEntry OBJECT-TYPE SYNTAX RadioModulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "radioModulation record." INDEX {radioIndex, radioChannelSpacing} ::= {radioModulationTable 1} RadioModulationEntry ::= SEQUENCE { radioChannelSpacing ChannelSpacing, radioModulationMap ModulationMap, radioRefModulationMap ModulationMap } radioChannelSpacing OBJECT-TYPE SYNTAX ChannelSpacing MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the channel spacing." ::= {radioModulationEntry 1} radioModulationMap OBJECT-TYPE SYNTAX ModulationMap MAX-ACCESS read-only STATUS current DESCRIPTION "List of modulations in the radioChanSpacing" ::= {radioModulationEntry 2} radioRefModulationMap OBJECT-TYPE SYNTAX ModulationMap MAX-ACCESS read-only STATUS current DESCRIPTION "List of modulations that can be selected as reference in the radioChanSpacingId" ::= {radioModulationEntry 3} -- ------- End of radioModulationTable ------- Begin of linkStatusTable -- linkStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with LinkStatusEntry." ::= {radioSystem 17} linkStatusEntry OBJECT-TYPE SYNTAX LinkStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link status entry" INDEX {linkIndex, linkPolIndex } ::= {linkStatusTable 1} LinkStatusEntry ::= SEQUENCE{ linkPolIndex INTEGER, linkAcmRxProfile Integer32, linkAcmTxProfile Integer32, linkAcmRxProfileLabel DisplayString, linkAcmTxProfileLabel DisplayString, linkAcmRxModulation BitsPerSymbol, linkAcmTxModulation BitsPerSymbol, linkAcmRxCode INTEGER, linkAcmTxCode INTEGER, linkTxETHCapacity Integer32, linkRxETHCapacity Integer32, linkTxTDMCapacity Integer32, linkRxTDMCapacity Integer32, linkRescueModulation BitsPerSymbol, linkReducedCapacityAlarm AlarmStatus, linkLinkTelemetryFailAlarm AlarmStatus, linkIdMismatchAlarm AlarmStatus, linkRadioEocAlarm AlarmStatus, linkSetupMismatchAlarm AlarmStatus, linkRescueSetupAlarm AlarmStatus, linkXpicProcedureBlockAlarm AlarmStatus, linkXpicRemTxOffAlarm AlarmStatus, linkRemoteIduAlarmSynthesis AlarmStatus, linkNotMatchingRadiosAlarm AlarmStatus, linkConfigurationInProgress INTEGER, linkXpd Integer32 } linkPolIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the radio polarization. In XPIC radio link identifies one of the polarizations." ::= {linkStatusEntry 1} linkAcmRxProfile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the ACM profile number in use in the radio Rx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable" ::= {linkStatusEntry 2} linkAcmTxProfile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the ACM profile number in use in the radio Tx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable" ::= {linkStatusEntry 3} linkAcmRxProfileLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string used to describe current acm rx profile" ::= {linkStatusEntry 4} linkAcmTxProfileLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string used to describe current acm tx profile" ::= {linkStatusEntry 5} linkAcmRxModulation OBJECT-TYPE SYNTAX BitsPerSymbol MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the type of modulation of the Rx profile in use." ::= {linkStatusEntry 6} linkAcmTxModulation OBJECT-TYPE SYNTAX BitsPerSymbol MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the type of modulation of the Tx profile in use." ::= {linkStatusEntry 7} linkAcmRxCode OBJECT-TYPE SYNTAX INTEGER { unknown (0), normal (1), strong (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the type of codificator of the Rx profile in use." ::= {linkStatusEntry 8} linkAcmTxCode OBJECT-TYPE SYNTAX INTEGER { unknown (0), normal (1), strong (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the type of codificator of the Tx profile in use." ::= {linkStatusEntry 9} linkTxETHCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports (in Kbits/sec) the transmitted payload capacity used by the Ethernet" DEFVAL { 0 } ::= {linkStatusEntry 10} linkRxETHCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports (in Kbits/sec) the received payload capacity used by the Ethernet" DEFVAL { 0 } ::= {linkStatusEntry 11} linkTxTDMCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the capacity in kbit/sec reserved to TDM tributaries in tx ACM profile." DEFVAL { 0 } ::= {linkStatusEntry 12} linkRxTDMCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the capacity in kbit/sec reserved to TDM tributaries in rx ACM profile." DEFVAL { 0 } ::= {linkStatusEntry 13} linkRescueModulation OBJECT-TYPE SYNTAX BitsPerSymbol MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the modulation used when the remote terminal is unreachable, ie traffic on radio link is down." DEFVAL { bps4QAM } ::= {linkStatusEntry 14} linkReducedCapacityAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The equipment works in reduced capacity" ::= {linkStatusEntry 15} linkLinkTelemetryFailAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Fail of link telemetry communication channel with associated Severity" ::= {linkStatusEntry 16} linkIdMismatchAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Link Identification Alarm with associated Severity" ::= {linkStatusEntry 17} linkRadioEocAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Fail of Radio Eoc link communication channel with associated Severity" ::= {linkStatusEntry 18} linkSetupMismatchAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The local setup doesn't match the setup of remote terminal" ::= {linkStatusEntry 19} linkRescueSetupAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The equipment is using the setup relative to the rescue modulation" ::= {linkStatusEntry 20} linkXpicProcedureBlockAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Only for XPIC equipment configurations. Equipment Controller XPIC procedure Alarm control with associated Severity" ::= {linkStatusEntry 21} linkXpicRemTxOffAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Only for XPIC equipment configurations. Remote TX OFF command with associated Severity" ::= {linkStatusEntry 22} linkRemoteIduAlarmSynthesis OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Synthesis of the remote IDU alarms" ::= {linkStatusEntry 23} linkNotMatchingRadiosAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Radios of the link does not have matched parameters." ::= {linkStatusEntry 24} linkConfigurationInProgress OBJECT-TYPE SYNTAX INTEGER { cleared (1), active (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link is being configured and the table linkSettingsTable is not available for modifying parameters. " ::= {linkStatusEntry 25} linkXpd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one. " ::= {linkStatusEntry 26} -- ------- End of linkStatusTable ------- Begin of linkTfcTable -- linkTfcTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkTfcEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch. This table was deprecated and replaced by linkTfcV2Table. It is a view of the rows of the linkTfcV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers. " ::= {radioSystem 18} linkTfcEntry OBJECT-TYPE SYNTAX LinkTfcEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Radio link TFC entry." INDEX {linkIndex} ::= {linkTfcTable 1} LinkTfcEntry ::= SEQUENCE { linkTfcAction INTEGER, linkTfcControl INTEGER, linkTfcWatchWindow INTEGER, linkTfcAlarmThreshold INTEGER, linkTfcAlarm AlarmStatus, linkTfcRowStatus RowStatus } linkTfcAction OBJECT-TYPE SYNTAX INTEGER { notActive (0), reset (1) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." ::= {linkTfcEntry 1} linkTfcControl OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system)." DEFVAL {disable} ::= {linkTfcEntry 2} linkTfcWatchWindow OBJECT-TYPE SYNTAX INTEGER (1..300) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." DEFVAL { 60 } ::= {linkTfcEntry 3} linkTfcAlarmThreshold OBJECT-TYPE SYNTAX INTEGER (1..60) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." DEFVAL { 10 } ::= {linkTfcEntry 4} linkTfcAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." ::= {linkTfcEntry 5} linkTfcRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Status of this conceptual row in linkTfcTable." ::= {linkTfcEntry 6} -- ------- End of linkTfcTable ------- Begin of linkMaintTable -- linkMaintTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with commands for maintenance of radio link. Objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry" ::= {radioSystem 19} linkMaintEntry OBJECT-TYPE SYNTAX LinkMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio link maintenance entry." INDEX {linkIndex, linkPolIndex} ::= {linkMaintTable 1} LinkMaintEntry ::= SEQUENCE { linkBerStart INTEGER, linkBaseBandLom INTEGER, linkFadeMarginMeasure INTEGER, linkXpicControlProcedureReset INTEGER } linkBerStart OBJECT-TYPE SYNTAX INTEGER { restart (1), stop (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Stop, Start (resetting errors and counters) the pattern. This item is linked to a manual operation (ManOpRecord) instance." DEFVAL {stop} ::= {linkMaintEntry 1} linkBaseBandLom OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to enable the IP packet forwarding towards modems. This item is linked to a manual operation (ManOpRecord) instance." DEFVAL {disable} ::= {linkMaintEntry 2} linkFadeMarginMeasure OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance. This object is deprecated and replaced by fadeMarginMeasure. " DEFVAL { disable } ::= {linkMaintEntry 3} linkXpicControlProcedureReset OBJECT-TYPE SYNTAX INTEGER { notActive (0), reset (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set by manager to reset the XPIC control procedure after a blocking action." DEFVAL {notActive} ::= {linkMaintEntry 4} -- ------- End of linkMaintTable ------- Begin of linkBerTable -- linkBerTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkBerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with Command to estimate BER of radio equipment. Every objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry" ::= {radioSystem 20} linkBerEntry OBJECT-TYPE SYNTAX LinkBerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio equipment BER estimate record." INDEX {linkIndex, linkPolIndex} ::= {linkBerTable 1} LinkBerEntry ::= SEQUENCE { linkBerErrorCounterH Counter32, linkBerErrorCounterL Counter32, linkBerDataCounterH Counter32, linkBerDataCounterL Counter32, linkBerSyncLossAlarm AlarmStatus, linkBerSyncLossAlarmCounter Integer32, linkBerElapsedTime Integer32 } linkBerErrorCounterH OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "High 32 bit part of the 64 bit error counter. Bit 32-63." ::= {linkBerEntry 1} linkBerErrorCounterL OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Low 32 bit part of the 64 bit error counter. Bit 0-31." ::= {linkBerEntry 2} linkBerDataCounterH OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "High 32 bit part of the 64 bit data counter. Bit 32-63." ::= {linkBerEntry 3} linkBerDataCounterL OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Low 32 bit part of the 64 bit data counter. Bit 0-31." ::= {linkBerEntry 4} linkBerSyncLossAlarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "BER sync loss alarm." ::= {linkBerEntry 5} linkBerSyncLossAlarmCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BER sync loss events counter." ::= {linkBerEntry 6} linkBerElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BER measure elapsed time." ::= {linkBerEntry 7} -- ------- End of linkBerTable ------- Begin of linkAcmTable -- linkAcmTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkAcmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with link records." ::= {radioSystem 21} linkAcmEntry OBJECT-TYPE SYNTAX LinkAcmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "ACM entries." INDEX {linkIndex, linkPolIndex, linkAcmProfileId} ::= {linkAcmTable 1} LinkAcmEntry ::= SEQUENCE { linkAcmProfileId Integer32, linkAcmProfileModulation BitsPerSymbol, linkAcmProfileCode INTEGER, linkAcmProfileCapacity Integer32, linkAcmProfileLabel DisplayString, linkAcmMaxTDMCapacity Integer32, linkAcmPowerScaling Integer32, linkAcmProfileEnable INTEGER, linkAcmDownshiftThreshold Integer32, linkAcmUpshiftThreshold Integer32, linkAcmActiveProfile INTEGER, linkAcmTDMCapacity Integer32, linkAcmETHCapacity Integer32, linkAcmAtpcRxPowerScaling Integer32, linkAcmPowerRange Integer32 } linkAcmProfileId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the profile number for the radio selected by the object linkAcmId." ::= {linkAcmEntry 1} linkAcmProfileModulation OBJECT-TYPE SYNTAX BitsPerSymbol MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the modulation of the profile." ::= {linkAcmEntry 2} linkAcmProfileCode OBJECT-TYPE SYNTAX INTEGER { normal (1), strong (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the type of codificator of the profile." ::= {linkAcmEntry 3} linkAcmProfileCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to contain total capacity of profile (in kbits/sec)." ::= {linkAcmEntry 4} linkAcmProfileLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string used to assign a name to profile." ::= {linkAcmEntry 5} linkAcmProfileEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The object is used to contain if the use of this profile is enabled or disabled" DEFVAL {enable} ::= {linkAcmEntry 6} linkAcmMaxTDMCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object reports the maximum capacity that can be assigned to the TDM traffic. The capacity is specified in number of E1 (2Mbit/s). This object has been superseded by linkE1vsSTM1CapacityTable. " DEFVAL {0} ::= {linkAcmEntry 7} linkAcmPowerScaling OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable. This object is deprecated: see combinedRadioPowerScalingTable." ::= {linkAcmEntry 8} linkAcmDownshiftThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object is used to contain the downshift threshold in dB/10." ::= {linkAcmEntry 9} linkAcmUpshiftThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object is used to contain the upshift threshold in dB/10." ::= {linkAcmEntry 10} linkAcmActiveProfile OBJECT-TYPE SYNTAX INTEGER { cleared (1), activeRx (2), activeTx (3), activeBoth (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to contain the active status of this profile. The value of the object is related to linkAcmRxProfile and linkAcmTxProfile of the LinkStatusEntry." DEFVAL {cleared} ::= {linkAcmEntry 11} linkAcmTDMCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports current TDM capacity (in kbits/sec) of the profile." ::= {linkAcmEntry 12} linkAcmETHCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports current ETH capacity (in Kbits/sec) of the profile." ::= {linkAcmEntry 13} linkAcmAtpcRxPowerScaling OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation. This object is deprecated: see combinedRadioPowerScalingTable." ::= {linkAcmEntry 14} linkAcmPowerRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains (in dB) the current value of ATPC range. This object is deprecated: see combinedRadioPowerScalingTable." ::= {linkAcmEntry 15} -- ------- End of linkAcmTable ------- Begin of linkProTable -- linkProTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkProEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A list of protection link entries. This table was deprecated and replaced by linkProV2Table. It is a view of the rows of the linkProV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers " ::= {radioSystem 22} linkProEntry OBJECT-TYPE SYNTAX LinkProEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry containing management information applicable to a protected link. " INDEX {linkIndex} ::= {linkProTable 1} LinkProEntry ::= SEQUENCE { linkProProtectionTxChIdx Integer32, linkProProtectionRxChIdx Integer32, linkProTxWtrTime INTEGER, linkProRxWtrTime INTEGER, linkProTxSwitchedChIdx Integer32, linkProRxSwitchedChIdx Integer32, linkProTxRevertive INTEGER, linkProRxRevertive INTEGER, linkProExtraTraffic INTEGER, linkProRowStatus RowStatus } linkProProtectionTxChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. " DEFVAL {0} ::= {linkProEntry 1} linkProProtectionRxChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. " DEFVAL {0} ::= {linkProEntry 2} linkProTxWtrTime OBJECT-TYPE SYNTAX INTEGER (0..12) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. " DEFVAL {0} ::= {linkProEntry 3} linkProRxWtrTime OBJECT-TYPE SYNTAX INTEGER (0..12) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. " DEFVAL {0} ::= {linkProEntry 4} linkProTxSwitchedChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema. " DEFVAL {0} ::= {linkProEntry 5} linkProRxSwitchedChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema. " DEFVAL {0} ::= {linkProEntry 6} linkProTxRevertive OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. " DEFVAL {disable} ::= {linkProEntry 7} linkProRxRevertive OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. " DEFVAL {disable} ::= {linkProEntry 8} linkProExtraTraffic OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1. " DEFVAL {disable} ::= {linkProEntry 9} linkProRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Status of this conceptual row in linkProTable. " ::= {linkProEntry 10} -- ------- End of linkProTable ------- Begin of linkProMaintTable -- linkProMaintTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkProMaintEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProTable. This table was deprecated and replaced by linkProMaintV2Table. It is a view of the rows of the linkProMaintV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers " ::= {radioSystem 23} linkProMaintEntry OBJECT-TYPE SYNTAX LinkProMaintEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry containing maintenance commands applicable to a protected link. " INDEX {linkIndex} ::= {linkProMaintTable 1} LinkProMaintEntry ::= SEQUENCE { linkProMaintTxLockout INTEGER, linkProMaintRxLockout INTEGER, linkProMaintTxForced Integer32, linkProMaintRxForced Integer32, linkProMaintTxWtrReset INTEGER, linkProMaintRxWtrReset INTEGER } linkProMaintTxLockout OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections. " DEFVAL {disable} ::= {linkProMaintEntry 1} linkProMaintRxLockout OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections. " DEFVAL {disable} ::= {linkProMaintEntry 2} linkProMaintTxForced OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Command to force switch to a given transmission channel. Zero value means no switch. " DEFVAL {0} ::= {linkProMaintEntry 3} linkProMaintRxForced OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Command to force switch to a given receiving channel. Zero value means no switch. " DEFVAL {0} ::= {linkProMaintEntry 4} linkProMaintTxWtrReset OBJECT-TYPE SYNTAX INTEGER { notActive (1), on (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Clear wait time to restore making the revertive path immediately available. " DEFVAL {notActive} ::= {linkProMaintEntry 5} linkProMaintRxWtrReset OBJECT-TYPE SYNTAX INTEGER { notActive (1), on (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Clear wait time to restore making the revertive path immediately available. " DEFVAL {notActive} ::= {linkProMaintEntry 6} -- ------- End of linkProMaintTable ------- Begin of linkCapabilitiesTable -- linkCapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkCapabilitiesEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Table with RadioCapabilities entries: there is an entry for each linkTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the capabilities of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable." ::= {radioSystem 24} linkCapabilitiesEntry OBJECT-TYPE SYNTAX LinkCapabilitiesEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "LinkCapabilities entry." INDEX {linkIndex} ::= {linkCapabilitiesTable 1} LinkCapabilitiesEntry ::= SEQUENCE { linkCapabilitiesCapability RadioCapability, linkCapabilitiesTxMinFrequency Integer32, linkCapabilitiesTxMaxFrequency Integer32, linkCapabilitiesStepFrequency Integer32, linkCapabilitiesMinPtxNominalValue Integer32, linkCapabilitiesMaxPtxNominalValue Integer32, linkCapabilitiesExtendedMinPwr Integer32 } linkCapabilitiesCapability OBJECT-TYPE SYNTAX RadioCapability MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Bit map to describe the radio features." ::= {linkCapabilitiesEntry 1} linkCapabilitiesTxMinFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Minimum of available channel frequency in KHz." ::= {linkCapabilitiesEntry 2} linkCapabilitiesTxMaxFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Maximum of available channel frequency in KHz." ::= {linkCapabilitiesEntry 3} linkCapabilitiesStepFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Minimum frequency step in KHz." ::= {linkCapabilitiesEntry 4} linkCapabilitiesMinPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Minimum nominal Ptx in dBm." ::= {linkCapabilitiesEntry 5} linkCapabilitiesMaxPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Maximum nominal Ptx in dBm." ::= {linkCapabilitiesEntry 6} linkCapabilitiesExtendedMinPwr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Minimum extended Ptx power for fade margin." ::= {linkCapabilitiesEntry 7} -- ------- End of linkCapabilitiesTable ------- Begin of linkFrequencyTable -- linkFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkFreqEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioFrequencyTable." ::= {radioSystem 25} linkFreqTabEntry OBJECT-TYPE SYNTAX LinkFreqEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "LinkFreqTab record." INDEX {linkIndex, linkFreqChannelId} ::= {linkFrequencyTable 1} LinkFreqEntry ::= SEQUENCE { linkFreqChannelId Integer32, linkFreqChannelNum Integer32, linkFreqValue Integer32 } linkFreqChannelId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Index of the table" ::= {linkFreqTabEntry 1} linkFreqChannelNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Available channel number." ::= {linkFreqTabEntry 2} linkFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Frequency related to linkFreqChannelNum." ::= {linkFreqTabEntry 3} -- ------- End of linkFrequencyTable ------- Begin of linkDuplexFrequencyTable -- linkDuplexFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkDuplexFreqEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioDuplexFrequencyTable." ::= {radioSystem 26} linkDuplexFreqEntry OBJECT-TYPE SYNTAX LinkDuplexFreqEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Duplex Frequency entry. For each available duplex frequency" INDEX {linkIndex, linkDuplexFreqId} ::= {linkDuplexFrequencyTable 1} LinkDuplexFreqEntry ::= SEQUENCE { linkDuplexFreqId Integer32, linkDuplexFreqValue Integer32 } linkDuplexFreqId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Index of the table." ::= {linkDuplexFreqEntry 1} linkDuplexFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Duplex frequency in KHz." ::= {linkDuplexFreqEntry 2} -- ------- End of linkDuplexFrequencyTable ------- Begin of linkModulationTable -- linkModulationTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkModulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. " ::= {radioSystem 27} linkModulationEntry OBJECT-TYPE SYNTAX LinkModulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "linkModulation record." INDEX {linkIndex, linkChannelSpacing} ::= {linkModulationTable 1} LinkModulationEntry ::= SEQUENCE { linkChannelSpacing ChannelSpacing, linkModulationMap ModulationMap, linkRefModulationMap ModulationMap } linkChannelSpacing OBJECT-TYPE SYNTAX ChannelSpacing MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the channel spacing." ::= {linkModulationEntry 1} linkModulationMap OBJECT-TYPE SYNTAX ModulationMap MAX-ACCESS read-only STATUS current DESCRIPTION "List of modulation in the linkChanSpacing" ::= {linkModulationEntry 2} linkRefModulationMap OBJECT-TYPE SYNTAX ModulationMap MAX-ACCESS read-only STATUS current DESCRIPTION "List of modulations that can be selected as reference in the linkChanSpacingId" ::= {linkModulationEntry 3} -- ------- End of linkModulationTable ------- Begin of linkChCapabilitiesTable -- combinedRadioCapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF CombinedRadioCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with RadioCapabilities entries: there is an entry for each radioSettingTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios belonging to the link. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable." ::= {radioSystem 28} combinedRadioCapabilitiesEntry OBJECT-TYPE SYNTAX CombinedRadioCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "combinedRadioCapabilities entry." INDEX {radioSettingsIndex} ::= {combinedRadioCapabilitiesTable 1} CombinedRadioCapabilitiesEntry ::= SEQUENCE { combinedRadioCapabilitiesCapability RadioCapability, combinedRadioCapabilitiesTxMinFrequency Integer32, combinedRadioCapabilitiesTxMaxFrequency Integer32, combinedRadioCapabilitiesStepFrequency Integer32, combinedRadioCapabilitiesMinPtxNominalValue Integer32, combinedRadioCapabilitiesMaxPtxNominalValue Integer32, combinedRadioCapabilitiesExtendedMinPwr Integer32 } combinedRadioCapabilitiesCapability OBJECT-TYPE SYNTAX RadioCapability MAX-ACCESS read-only STATUS current DESCRIPTION "Bit map to describe the radio features." ::= {combinedRadioCapabilitiesEntry 1} combinedRadioCapabilitiesTxMinFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum of available channel frequency in KHz." ::= {combinedRadioCapabilitiesEntry 2} combinedRadioCapabilitiesTxMaxFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum of available channel frequency in KHz." ::= {combinedRadioCapabilitiesEntry 3} combinedRadioCapabilitiesStepFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum frequency step in KHz." ::= {combinedRadioCapabilitiesEntry 4} combinedRadioCapabilitiesMinPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum nominal Ptx in dBm." ::= {combinedRadioCapabilitiesEntry 5} combinedRadioCapabilitiesMaxPtxNominalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum nominal Ptx in dBm." ::= {combinedRadioCapabilitiesEntry 6} combinedRadioCapabilitiesExtendedMinPwr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum extended Ptx power for fade margin." ::= {combinedRadioCapabilitiesEntry 7} -- ------- End of combinedRadioCapabilitiesTable ------- Begin of combinedRadioFrequencyTable -- combinedRadioFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF CombinedRadioFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios." ::= {radioSystem 29} combinedRadioFreqTabEntry OBJECT-TYPE SYNTAX CombinedRadioFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "combinedRadioFreqTab record." INDEX {radioSettingsIndex, combinedRadioFreqChannelId} ::= {combinedRadioFrequencyTable 1} CombinedRadioFreqEntry ::= SEQUENCE { combinedRadioFreqChannelId Integer32, combinedRadioFreqChannelNum Integer32, combinedRadioFreqValue Integer32 } combinedRadioFreqChannelId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the table" ::= {combinedRadioFreqTabEntry 1} combinedRadioFreqChannelNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Available channel number." ::= {combinedRadioFreqTabEntry 2} combinedRadioFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency related to combinedRadioFreqChannelNum." ::= {combinedRadioFreqTabEntry 3} -- ------- End of combinedRadioFrequencyTable ------- Begin of combinedRadioDuplexFrequencyTable -- combinedRadioDuplexFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF CombinedRadioDuplexFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios." ::= {radioSystem 30} combinedRadioDuplexFreqEntry OBJECT-TYPE SYNTAX CombinedRadioDuplexFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duplex Frequency entry. There is an entry for each available duplex frequency." INDEX {radioSettingsIndex, combinedRadioDuplexFreqId} ::= {combinedRadioDuplexFrequencyTable 1} CombinedRadioDuplexFreqEntry ::= SEQUENCE { combinedRadioDuplexFreqId Integer32, combinedRadioDuplexFreqValue Integer32 } combinedRadioDuplexFreqId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the table." ::= {combinedRadioDuplexFreqEntry 1} combinedRadioDuplexFreqValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Duplex frequency in KHz." ::= {combinedRadioDuplexFreqEntry 2} -- ------- End of combinedRadioDuplexFrequencyTable ------- Begin of combinedRadioPowerScalingTable -- combinedRadioPowerScalingTable OBJECT-TYPE SYNTAX SEQUENCE OF CombinedRadioPowerScalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios." ::= {radioSystem 31} combinedRadioPowerScalingEntry OBJECT-TYPE SYNTAX CombinedRadioPowerScalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "radioPowerScaling record." INDEX {radioSettingsIndex, linkAcmProfileId} ::= {combinedRadioPowerScalingTable 1} CombinedRadioPowerScalingEntry ::= SEQUENCE { combinedRadioPowerScaling Integer32, combinedRadioAtpcRxPowerScaling Integer32, combinedRadioPowerRange Integer32 } combinedRadioPowerScaling OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable." ::= {combinedRadioPowerScalingEntry 1} combinedRadioAtpcRxPowerScaling OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation." ::= {combinedRadioPowerScalingEntry 2} combinedRadioPowerRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains (in dB) the current value of ATPC range." ::= {combinedRadioPowerScalingEntry 3} -- ------- End of radioPowerScalingTable ------- Begin of stm1BulkSettingsTable -- stm1BulkMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF Stm1BulkMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with entries containing stm-1 bulk transport parameters for a particular link. For each link are present as many rows as the STM-1 that the link can carry in bulk mode. " ::= {radioSystem 32} stm1BulkMappingEntry OBJECT-TYPE SYNTAX Stm1BulkMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An row in stm1BulkSettingsTable. " INDEX {linkIndex, stm1BulkPolIndex, stm1BulkChanIndex} ::= {stm1BulkMappingTable 1} Stm1BulkMappingEntry ::= SEQUENCE { stm1BulkPolIndex Integer32, stm1BulkChanIndex Integer32, stm1BulkChannel Stm1IndexOrZero } stm1BulkPolIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Polarization index. " ::= {stm1BulkMappingEntry 1} stm1BulkChanIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "STM-1 channel index. The range of this object is from 1 to N, where N is the number of STM-1 that a link can carry in bulk mode. " ::= {stm1BulkMappingEntry 2} stm1BulkChannel OBJECT-TYPE SYNTAX Stm1IndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "Index of the stm-1 in stm1Table. The SNMP agent will accept only index of a STM-1 present in stm1Table with stm1Structure set to opaque(4). " DEFVAL {0} ::= {stm1BulkMappingEntry 3} -- ------- End of stm1BulkSettingsTable ------- Begin of linkE1vsSTM1CapacityTable -- linkE1vsSTM1CapacityTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkE1vsSTM1CapacityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with entries containing the E1 cpacity according to the tributaries STM-1 configured to be carried in bulk mode. " ::= {radioSystem 33} linkE1vsSTM1CapacityEntry OBJECT-TYPE SYNTAX LinkE1vsSTM1CapacityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An row in linkE1vsSTM1CapacityTable. " INDEX {linkIndex, linkAcmProfileId, linkE1vsSTM1CapacityStm1} ::= {linkE1vsSTM1CapacityTable 1} LinkE1vsSTM1CapacityEntry ::= SEQUENCE { linkE1vsSTM1CapacityStm1 Integer32, linkE1vsSTM1CapacityE1 Integer32 } linkE1vsSTM1CapacityStm1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of tributaries STM-1 configured to be transported in bulk mode. " ::= {linkE1vsSTM1CapacityEntry 1 } linkE1vsSTM1CapacityE1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of E1 that can be carried by this profile according to the the tributaries STM-1 carried in bulk mode. " ::= {linkE1vsSTM1CapacityEntry 2} -- ------- End of linkE1vsSTM1CapacityTable ------- Begin of linkTfcV2Table -- linkTfcV2Table OBJECT-TYPE SYNTAX SEQUENCE OF LinkTfcV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch." ::= {radioSystem 34} linkTfcV2Entry OBJECT-TYPE SYNTAX LinkTfcV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio link TFC entry." INDEX {linkIndex, linkPolIndex} ::= {linkTfcV2Table 1} LinkTfcV2Entry ::= SEQUENCE { linkTfcV2Action INTEGER, linkTfcV2Control INTEGER, linkTfcV2WatchWindow INTEGER, linkTfcV2AlarmThreshold INTEGER, linkTfcV2Alarm AlarmStatus, linkTfcV2RowStatus RowStatus } linkTfcV2Action OBJECT-TYPE SYNTAX INTEGER { notActive (0), reset (1) } MAX-ACCESS read-create STATUS current DESCRIPTION "reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." ::= {linkTfcV2Entry 1} linkTfcV2Control OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system)." DEFVAL {disable} ::= {linkTfcV2Entry 2} linkTfcV2WatchWindow OBJECT-TYPE SYNTAX INTEGER (1..300) MAX-ACCESS read-create STATUS current DESCRIPTION "Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." DEFVAL { 60 } ::= {linkTfcV2Entry 3} linkTfcV2AlarmThreshold OBJECT-TYPE SYNTAX INTEGER (1..60) MAX-ACCESS read-create STATUS current DESCRIPTION "Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." DEFVAL { 10 } ::= {linkTfcV2Entry 4} linkTfcV2Alarm OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system)." ::= {linkTfcV2Entry 5} linkTfcV2RowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this conceptual row in linkTfcV2Table." ::= {linkTfcV2Entry 6} -- ------- End of linkTfcV2Table ------- Begin of linkProV2Table -- linkProV2Table OBJECT-TYPE SYNTAX SEQUENCE OF LinkProV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of protection link entries. " ::= {radioSystem 35} linkProV2Entry OBJECT-TYPE SYNTAX LinkProV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a protected link. " INDEX {linkIndex, linkPolIndex} ::= {linkProV2Table 1} LinkProV2Entry ::= SEQUENCE { linkProV2ProtectionTxChIdx Integer32, linkProV2ProtectionRxChIdx Integer32, linkProV2TxWtrTime INTEGER, linkProV2RxWtrTime INTEGER, linkProV2TxSwitchedChIdx Integer32, linkProV2RxSwitchedChIdx Integer32, linkProV2TxRevertive INTEGER, linkProV2RxRevertive INTEGER, linkProV2ExtraTraffic INTEGER, linkProV2RowStatus RowStatus } linkProV2ProtectionTxChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. " DEFVAL {0} ::= {linkProV2Entry 1} linkProV2ProtectionRxChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. " DEFVAL {0} ::= {linkProV2Entry 2} linkProV2TxWtrTime OBJECT-TYPE SYNTAX INTEGER (0..12) MAX-ACCESS read-create STATUS current DESCRIPTION "It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. " DEFVAL {0} ::= {linkProV2Entry 3} linkProV2RxWtrTime OBJECT-TYPE SYNTAX INTEGER (0..12) MAX-ACCESS read-create STATUS current DESCRIPTION "It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. " DEFVAL {0} ::= {linkProV2Entry 4} linkProV2TxSwitchedChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema. " DEFVAL {0} ::= {linkProV2Entry 5} linkProV2RxSwitchedChIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema. " DEFVAL {0} ::= {linkProV2Entry 6} linkProV2TxRevertive OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. " DEFVAL {disable} ::= {linkProV2Entry 7} linkProV2RxRevertive OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. " DEFVAL {disable} ::= {linkProV2Entry 8} linkProV2ExtraTraffic OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1. " DEFVAL {disable} ::= {linkProV2Entry 9} linkProV2RowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this conceptual row in linkProV2Table. " ::= {linkProV2Entry 10} -- ------- End of linkProV2Table ------- Begin of linkProMaintV2Table -- linkProMaintV2Table OBJECT-TYPE SYNTAX SEQUENCE OF LinkProMaintV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProV2Table. " ::= {radioSystem 36} linkProMaintV2Entry OBJECT-TYPE SYNTAX LinkProMaintV2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing maintenance commands applicable to a protected link. " INDEX {linkIndex, linkPolIndex} ::= {linkProMaintV2Table 1} LinkProMaintV2Entry ::= SEQUENCE { linkProMaintV2TxLockout INTEGER, linkProMaintV2RxLockout INTEGER, linkProMaintV2TxForced Integer32, linkProMaintV2RxForced Integer32, linkProMaintV2TxWtrReset INTEGER, linkProMaintV2RxWtrReset INTEGER } linkProMaintV2TxLockout OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections. " DEFVAL {disable} ::= {linkProMaintV2Entry 1} linkProMaintV2RxLockout OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections. " DEFVAL {disable} ::= {linkProMaintV2Entry 2} linkProMaintV2TxForced OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Command to force switch to a given transmission channel. Zero value means no switch. " DEFVAL {0} ::= {linkProMaintV2Entry 3} linkProMaintV2RxForced OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Command to force switch to a given receiving channel. Zero value means no switch. " DEFVAL {0} ::= {linkProMaintV2Entry 4} linkProMaintV2TxWtrReset OBJECT-TYPE SYNTAX INTEGER { notActive (1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear wait time to restore making the revertive path immediately available. " DEFVAL {notActive} ::= {linkProMaintV2Entry 5} linkProMaintV2RxWtrReset OBJECT-TYPE SYNTAX INTEGER { notActive (1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear wait time to restore making the revertive path immediately available. " DEFVAL {notActive} ::= {linkProMaintV2Entry 6} -- ------- End of linkProMaintV2Table ------- Begin of sspTable -- sspTable OBJECT-TYPE SYNTAX SEQUENCE OF SspEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of operative and administrative set of parameters. This table holds three row for every link (and its polarizations) configured in the NE: 1) administative parameters of local NE 2) operative parameters of local NE 3) administative parameters of remote NE " ::= {radioSystem 37} sspEntry OBJECT-TYPE SYNTAX SspEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing SSP relevant parameters. " INDEX {linkIndex, linkPolIndex, sspParameterType} ::= {sspTable 1} SspEntry ::= SEQUENCE { sspParameterType INTEGER, sspLinkBandwidth INTEGER, sspLinkModulation INTEGER, sspLinkAcmEngineEnable INTEGER, sspLinkTxUpperProfile INTEGER, sspLinkTxLowerProfile INTEGER, sspLinkSynchSetupProtocolEnable INTEGER, sspLinkProfilesSetSelection INTEGER, sspTdmE1Channel Integer32, sspTdmStm1Channel Integer32 } sspParameterType OBJECT-TYPE SYNTAX INTEGER { localAdminStatus (1), localOperStatus (2), remoteAdminStatus (3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies what parameters are for. " ::= {sspEntry 1} sspLinkBandwidth OBJECT-TYPE SYNTAX INTEGER { sspBw3p5Mhz (0), sspBw7MHz (1), sspBw14MHz (2), sspBw28MHz (3), sspBw56MHz (4), sspBw10MHz (5), sspBw20MHz (6), sspBw30MHz (7), sspBw40MHz (8), sspBw50MHz (9), sspBw112Mhz (10), sspBw250Mhz (11), sspBw500Mhz (12), sspBw750Mhz (13), sspBw1Ghz (14), sspBw60MHz (15), sspBw80MHz (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link Bandwidth (channel spacing). " ::= {sspEntry 2} sspLinkModulation OBJECT-TYPE SYNTAX INTEGER{ sspModBPSK (1), sspMod4QAM (2), sspMod8PSK (3), sspMod16QAM (4), sspMod32QAM (5), sspMod64QAM (6), sspMod128QAM (7), sspMod256QAM (8), sspMod512QAM (9), sspMod1024QAM (10), sspMod2048QAM (11), sspMod4096QAM (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link reference modulation. " ::= {sspEntry 3} sspLinkAcmEngineEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to enable/disable the ACM engine. " DEFVAL { disable } ::= {sspEntry 4} sspLinkTxUpperProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled. " ::= {sspEntry 5} sspLinkTxLowerProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled. " ::= {sspEntry 6} sspLinkSynchSetupProtocolEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Synchronization Setup Protocol (SSP) control. " ::= {sspEntry 7} sspLinkProfilesSetSelection OBJECT-TYPE SYNTAX INTEGER { highThroughput (1), highGain (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported. " ::= {sspEntry 8} sspTdmE1Channel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s). " ::= {sspEntry 9} sspTdmStm1Channel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of STM-1 channels transported in bulk mode. " ::= {sspEntry 10} -- ------- End of sspTable ------- Begin of radioLoopCapabilityTable -- radioLoopCapabilityTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioLoopCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows which group a radio loop belongs to. Radios with the same group number (identifier) close loop simultaneously. " ::= {radioSystem 38} radioLoopCapabilityEntry OBJECT-TYPE SYNTAX RadioLoopCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a group identifier for each radio loop type. " INDEX {radioIndex} ::= {radioLoopCapabilityTable 1} RadioLoopCapabilityEntry ::= SEQUENCE { radioLoopRfGroup Integer32, radioLoopIqGroup Integer32, radioLoopBaseBandGroup Integer32 } radioLoopRfGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group to which the radio RF loop belong to. " ::= {radioLoopCapabilityEntry 1} radioLoopIqGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group to which the radio IQ loop belong to. " ::= {radioLoopCapabilityEntry 2} radioLoopBaseBandGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group to which the radio base loop belong to. " ::= {radioLoopCapabilityEntry 3} -- ------- End of radioLoopCapabilityTable ------- Begin of radioRxThresholdTable -- radioRxBerThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF RadioRxBerThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the nominal and measured values of RX power at a bit error rate (BER) equal to 10e-6. " ::= {radioSystem 39} radioRxBerThresholdEntry OBJECT-TYPE SYNTAX RadioRxBerThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the RX power thresholds. " INDEX {radioIndex} ::= {radioRxBerThresholdTable 1} RadioRxBerThresholdEntry ::= SEQUENCE { radioRxBerThresholdStatus INTEGER, radioNominalRxBerThreshold Integer32, radioMeasuredRxBerThreshold Integer32 } radioRxBerThresholdStatus OBJECT-TYPE SYNTAX INTEGER { nonValid (1), valid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object shows whether the following objects are significant. " ::= {radioRxBerThresholdEntry 1} radioNominalRxBerThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal value of RX power @ BER equal to 10e-6 " ::= {radioRxBerThresholdEntry 2} radioMeasuredRxBerThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The measured value of RX power @ BER equal to 10e-6. " ::= {radioRxBerThresholdEntry 3} -- ------- End of radioRxThresholdTable radioRemDemodulatorFailAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioRemDemodulatorFailAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 50} radioRxActiveStatusTrapNotification OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for radioRxActivestatus" DEFVAL{ trapEnable } ::= {radioSystem 51} radioTxActiveStatusTrapNotification OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioTxActivestatus and enable/disable the trap generation on status change event." DEFVAL{ trapEnable } ::= {radioSystem 52} radioCableOpenAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioCableOpen and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 53} radioCableShortAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioCableShort and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 54} radioInvalidFrequencyAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioInvalidFrequencyAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 55} radioBaseBandRxAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioBaseBandRxAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 56} radioModulatorFailAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioModulatorFailAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 57} radioDemodulatorFailAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioDemodulatorFailAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 58} radioRxPowerLowAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioRxPowerLowAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 59} radioTxPowerLowAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioTxPowerLowAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 60} radioVcoFailAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioVcoFailAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 61} radioRxIFAgcAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioRxIFAgcAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 62} radioTxIFAgcAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioTxIFAgcAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 63} radioIduOduCommunicationAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioIduOduCommunicationAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 64} radioOduIduCommunicationAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioOduIduCommunicationAlarm and enable/disable the trap generation on status change event." DEFVAL {warningTrapEnable} ::= {radioSystem 65} radioLocalOduAlarmSynthesisSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioLocalOduAlarmSynthesis and enable/disable the trap generation on status change event." DEFVAL {statusTrapDisable} ::= {radioSystem 66} radioRemoteOduAlarmSynthesisSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioRemoteOduAlarmSynthesis and enable/disable the trap generation on status change event." DEFVAL {statusTrapDisable} ::= {radioSystem 67} radioConfigMismatchAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the severity associated to the radioConfigMismatchAlarm and enables/disables the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 68} radioPrxHysteresisValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the delta value associated to the radioPrx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed." DEFVAL {3} ::= {radioSystem 69} radioPtxHysteresisValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the delta value associated to the radioPtx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed." DEFVAL {3} ::= {radioSystem 70} radioPrxHysteresisValueTrapNotification OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the Rx change trap generation on status change event." DEFVAL {trapEnable} ::= {radioSystem 71} radioPtxHysteresisValueTrapNotification OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the Tx change trap generation on status change event." DEFVAL {trapEnable} ::= {radioSystem 72} radioRxQualityLowAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioRxQualityLowAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 73} radioRxQualityWarningAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the radioRxQualityWarningAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 74} linkReducedCapacityAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkReducedCapacityAlarm and enable/disable the trap generation on status change event." DEFVAL {warningTrapEnable} ::= {radioSystem 75} linkLinkTelemetryFailAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkLinkTelemetryFailAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 76} linkIdMismatchAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkIdMismatchAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 77} linkRadioEocAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkRadioEocAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 78} linkSetupMismatchAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkSetupMismatchAlarm and enable/disable the trap generation on status change event." DEFVAL {warningTrapEnable} ::= {radioSystem 79} linkRescueSetupAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkRescueSetupAlarm and enable/disable the trap generation on status change event." DEFVAL {criticalTrapEnable} ::= {radioSystem 80} linkXpicProcedureBlockAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkXpicProcedureBlockAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 81} linkXpicRemTxOffAlarmAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkXpicRemTxOffAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 82} linkLocalIduAlarmSynthesis OBJECT-TYPE SYNTAX AlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Synthesis of the local IDU alarms" ::= {radioSystem 83} linkLocalIduAlarmSynthesisSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event." DEFVAL{ statusTrapDisable } ::= {radioSystem 84} linkRemoteIduAlarmSynthesisSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event." DEFVAL{ statusTrapDisable } ::= {radioSystem 85} linkTfcAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm) and enable/disable the trap generation on status change event." DEFVAL { minorTrapEnable } ::= {radioSystem 86} linkBerSyncLossAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkBerSyncLossAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 87} linkNotMatchingRadiosAlarmSeverityCode OBJECT-TYPE SYNTAX AlarmSeverityCode MAX-ACCESS read-write STATUS current DESCRIPTION "Define the severity associated to the linkNotMatchingRadiosAlarm and enable/disable the trap generation on status change event." DEFVAL {majorTrapEnable} ::= {radioSystem 88} channelSpacingSelection OBJECT-TYPE SYNTAX BITS { etsi (0), fcc (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "his object selects which channel spacings the radio link has to support: - etsi: Compliant with European Telecommunication Standards Institute - fcc: Compliant with Federal Communications Commission " DEFVAL { { etsi, fcc } } ::= {radioSystem 89} fadeMarginMeasure OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance." DEFVAL { disable } ::= {radioSystem 90} linkConfigurationInProgressTrapNotification OBJECT-TYPE SYNTAX INTEGER { trapDisable (1), trapEnable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for linkConfigurationInProgress" DEFVAL{ trapEnable } ::= {radioSystem 91} ----------------------- -- This MIB module generates the following TRAPs: ----------------------- radioPrxChange NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPrx} STATUS current DESCRIPTION "This event is generated when radioPrx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assinged name 4) radioPrx - PRX value" ::= { alarmTrap 8001 } radioPtxChange NOTIFICATION-TYPE OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPtx} STATUS current DESCRIPTION "This event is generated when radioPtx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assigned name 4) radioPtx - PTX value" ::= { alarmTrap 8002 } ------ End group ----------------------------------------------------------------- ---------------------------------- End ------------------------------------- END