-- ********************************************************************* -- ** -- ** BATM Advanced Communications. -- ** -- ********************************************************************* -- ** Filename: PRVT-TEMIB-ENTITY-MIB.mib -- ** Project: T-Metro Switches. -- ** Purpose: Private MIB -- ********************************************************************* -- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved. -- WARNING: -- -- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: -- -- This file is the property of BATM Advanced Communications and contains -- proprietary and confidential information. This file is made -- available to authorized BATM customers on the express -- condition that neither it, nor any of the information contained -- therein, shall be disclosed to third parties or be used for any -- purpose other than to replace, modify or upgrade firmware and/or -- software components of BATM manufactured equipment within the -- authorized customer's network, and that such transfer be -- completed in accordance with the instructions provided by -- BATM. Any other use is strictly prohibited. -- -- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED -- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE -- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED -- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES -- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. -- -- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER -- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS -- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR -- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY -- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. -- -- ---------------------------------------------------------------------------- PRVT-TEMIB-ENTITY-MIB DEFINITIONS ::= BEGIN IMPORTS mpls FROM PRVT-SWITCH-MIB MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI RowStatus, TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC; prvtTeMibEntityMIB MODULE-IDENTITY LAST-UPDATED "200712060000Z" ORGANIZATION "BATM Advanced Communication" CONTACT-INFO "BATM/Telco Systems Support team Email: For North America: techsupport@telco.com For North Europe: support@batm.de, info@batm.de For the rest of the world: techsupport@telco.com" DESCRIPTION "The MIB module for management of TE-MIB entities." REVISION "200712060000Z" DESCRIPTION "Initial." ::= { mpls 8 } PrvtTeMibAdminStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The desired administrative state of a TE-MIB entity." SYNTAX INTEGER { up(1), down(2) } PrvtTeMibOperStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The current operational state of a TE-MIB entity." SYNTAX INTEGER { up(1), down(2), goingUp(3), goingDown(4), actFailed(5) } PrvtTeMibEntityIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The index value identifying a TE-MIB entity." SYNTAX Unsigned32 PrvtTeMibPartnerStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The state of a TE-MIB entity partner." SYNTAX INTEGER { initial(0), activating(1), active(2), deactivating(3), failedOver(4), failed(5), unavailable(6) } prvtTeMibEntityMIBObjects OBJECT IDENTIFIER ::= { prvtTeMibEntityMIB 1 } prvtMplsTeMibEntityTable OBJECT-TYPE SYNTAX SEQUENCE OF PrvtMplsTeMibEntityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of TE-MIB entities." ::= { prvtTeMibEntityMIBObjects 1 } prvtMplsTeMibEntityEntry OBJECT-TYPE SYNTAX PrvtMplsTeMibEntityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a TE-MIB entity." INDEX { prvtMplsTeMibEntityIndex } ::= { prvtMplsTeMibEntityTable 1 } PrvtMplsTeMibEntityEntry ::= SEQUENCE { prvtMplsTeMibEntityIndex PrvtTeMibEntityIndex, prvtMplsTeMibEntityRowStatus RowStatus, prvtMplsTeMibDynFacilityBypass TruthValue } prvtMplsTeMibEntityIndex OBJECT-TYPE SYNTAX PrvtTeMibEntityIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of this TE-MIB entity table entry. This is the HAF entity index passed on the entity create parameters." ::= { prvtMplsTeMibEntityEntry 1 } prvtMplsTeMibEntityRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status for the TE-MIB entity table entry, used to create and destroy TE-MIB entities. When prvtMplsTeMibEntityRowStatus is 'active' and prvtMplsTeMibEntityAdminStatus is 'up' the TE-MIB entity is active and only these two fields can be modified." ::= { prvtMplsTeMibEntityEntry 2 } prvtMplsTeMibDynFacilityBypass OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object gives the user ability to globally enable/disable automatically creation of bypass tunnels for all LSPs. Bypass tunnels will be created on FRR tunnel request automatically. The default value is true. The creation of Dynamic bypass tunnels is enabled" ::= { prvtMplsTeMibEntityEntry 3 } mplsTunnelHoldTimer OBJECT-TYPE SYNTAX Unsigned32 (0..120) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines a period in seconds needed to wait before rebuilding backup or primary tunnels if a frr condition occurs Currently no more than 10 seconds are allowed" ::= { prvtTeMibEntityMIBObjects 2 } prvtMplsTeMibEntityScalarTable OBJECT-TYPE SYNTAX SEQUENCE OF PrvtMplsTeMibEntityScalarEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mplsTeMibEntityScalarTable contains all MPLS Tunnel scalars." ::= { prvtTeMibEntityMIBObjects 3 } prvtMplsTeMibEntityScalarEntry OBJECT-TYPE SYNTAX PrvtMplsTeMibEntityScalarEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mplsTeMibEntityScalarTable contains all MPLS Tunnel scalars." INDEX { prvtMplsTeMibEntityIndex } ::= { prvtMplsTeMibEntityScalarTable 1 } PrvtMplsTeMibEntityScalarEntry ::= SEQUENCE { mplsTunnelConfigured Unsigned32, mplsTunnelActive Unsigned32 } mplsTunnelConfigured OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of tunnels configured on this device. A tunnel is considered configured if the mplsTunnelRowStatus is active(1)." ::= { prvtMplsTeMibEntityScalarEntry 1 } mplsTunnelActive OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of tunnels active on this device. A tunnel is considered active if the mplsTunnelOperStatus is up(1)." ::= { prvtMplsTeMibEntityScalarEntry 2 } END -- end of module PRVT-TEMIB-ENTITY-MIB.