-- -- TELESTE-LUMINATO-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 349 -- Wednesday, September 30, 2009 at 14:12:58 -- -- TELESTE-LUMINATO-MIB.mib -- -- ***************************************************************************** -- Copyright (c) 2000-2010 by: -- -- Teleste Corporation -- Seponkatu 1 -- FIN-20660 Littoinen, Finland -- tel. +358 2 2605 611 -- url: http://www.teleste.com -- -- Description: Objects for Luminato -- -- Revision History: -- ----------------- -- 1.2 16.02.2010 Sami Salo and Sergey Egorov -- - Changed OID 1.3.6.1.4.1.3715.17.2 from 'monitor' to 'statusCode' -- - Corrected types and ranges for PID, SID and TS IDs -- - Minor cosmetic corrections -- 1.1 30.09.2009 Rainer Salminen and Sami Salo -- - Added monitor and alarm object tables -- 1.0 19.02.2009 Sergey Egorov -- - Initial release -- **************************************************************************** -- TELESTE-LUMINATO-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TimeTicks FROM RFC1155-SMI DisplayString FROM RFC1213-MIB Unsigned32 FROM SNMPv2-SMI luminato FROM TELESTE-ROOT-MIB Float FROM UCD-SNMP-MIB; -- -- Node definitions -- -- General information of device -- 1.3.6.1.4.1.3715.17.1 general OBJECT IDENTIFIER ::= { luminato 1 } -- 1.3.6.1.4.1.3715.17.1.1 deviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The identification name ('aliasname') of the device" ::= { general 1 } -- 1.3.6.1.4.1.3715.17.1.2 generalStatus OBJECT-TYPE SYNTAX INTEGER { statusAlert(1), statusCritical(2), statusError(3), statusWarning(4), statusNotice(5), statusInformational(6), statusDebug(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "General status of device" ::= { general 2 } -- 1.3.6.1.4.1.3715.17.1.3 redundancyStatus OBJECT-TYPE SYNTAX INTEGER { redundancyStandalone(1), redundancyMaster(16), redundancyMasterHandover(24), redundancyBackup(32), redundancyBackupHandover(40), redundancyError(64) } MAX-ACCESS read-only STATUS optional DESCRIPTION "Status of device in 1+1 backup operation mode" ::= { general 3 } -- 1.3.6.1.4.1.3715.17.1.10 hwSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device serial number" ::= { general 10 } -- 1.3.6.1.4.1.3715.17.1.11 hwType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware type name of the device" ::= { general 11 } -- 1.3.6.1.4.1.3715.17.1.12 hwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device hardware version" ::= { general 12 } -- 1.3.6.1.4.1.3715.17.1.13 swVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device running software version" ::= { general 13 } -- 1.3.6.1.4.1.3715.17.1.14 upTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Device uptime" ::= { general 14 } -- 1.3.6.1.4.1.3715.17.1.15 cumulativeUptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Device cummulative uptime" ::= { general 15 } -- 1.3.6.1.4.1.3715.17.2 statusCode OBJECT IDENTIFIER ::= { luminato 2 } -- 1.3.6.1.4.1.3715.17.2.1 interfaceTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF InterfaceTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "InterfaceTypeTable lists possible interface types in the system." ::= { statusCode 1 } -- 1.3.6.1.4.1.3715.17.2.1.1 interfaceTypeEntry OBJECT-TYPE SYNTAX InterfaceTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each InterfaceTypeEntry describes type of the interface." INDEX { interfaceTypeId } ::= { interfaceTypeTable 1 } InterfaceTypeEntry ::= SEQUENCE { interfaceTypeId INTEGER } -- 1.3.6.1.4.1.3715.17.2.1.1.1 interfaceTypeId OBJECT-TYPE SYNTAX INTEGER { input(1), output(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interfacetype Id has two values input(1) and output(2). Values are used in other tables as index." ::= { interfaceTypeEntry 1 } -- 1.3.6.1.4.1.3715.17.2.2 statusCodeDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodeDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes monitorable objects of the device. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeDeviceTable shall be used to obtains text definition of alarm." ::= { statusCode 2 } -- 1.3.6.1.4.1.3715.17.2.2.1 statusCodeDeviceEntry OBJECT-TYPE SYNTAX StatusCodeDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { scdObjectId } ::= { statusCodeDeviceTable 1 } StatusCodeDeviceEntry ::= SEQUENCE { scdObjectId Unsigned32, scdObjectValue INTEGER, scdObjectDescriptor DisplayString, scdObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.2.1.1 scdObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object. " ::= { statusCodeDeviceEntry 1 } -- 1.3.6.1.4.1.3715.17.2.2.1.2 scdObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The scdObjectDescriptor tells name, scale and unit of the object." ::= { statusCodeDeviceEntry 2 } -- 1.3.6.1.4.1.3715.17.2.2.1.3 scdObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. Free text if object has two states or Format: Name, Scale, Unit, [optional text] ------------------------------------ Example 1 (Analogue object): 'MainVoltage, 0.01, V' Usage: scdObjectId:7 (example) scdObjectValue:2399 scdObjectDescriptor:'MainVoltage, 0.01, V' means Main voltage is 23.99 V ------------------------------------ Example 2 (Discrete object): 'TemperatureHigh, 1, high(2)/nominal(1), Alarm state of the temperature' Usage: scdObjectId:12 (example) scdObjectValue:2 means Temperature is in high alarm state. ------------------------------------ " ::= { statusCodeDeviceEntry 3 } -- 1.3.6.1.4.1.3715.17.2.2.1.4 scdObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "When the object has this value it is in the alarm state. One object id can have only one alarm state. If more alarm states exist then new associated object needs to be created. Note that alarm state value can have only discrete values. If the value is zero then there is no alarm for this object. Example: TemperatureHigh object can have values high(2) or nominal(1). Alarm monitoring for this object is triggered by setting dmObjectAlarmValue to value 2 meaning high(2). How the alarm processing is done is out of scope of this MIB. " ::= { statusCodeDeviceEntry 4 } -- 1.3.6.1.4.1.3715.17.2.3 statusCodeModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes monitorable objects per module inside the device. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeModuleTable shall be used to obtains text definition of alarm." ::= { statusCode 3 } -- 1.3.6.1.4.1.3715.17.2.3.1 statusCodeModuleEntry OBJECT-TYPE SYNTAX StatusCodeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { scmModuleId, scmObjectId } ::= { statusCodeModuleTable 1 } StatusCodeModuleEntry ::= SEQUENCE { scmModuleId INTEGER, scmObjectId Unsigned32, scmObjectValue INTEGER, scmObjectDescriptor DisplayString, scmObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.3.1.1 scmModuleId OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Module Id within the device (usually slot number)." ::= { statusCodeModuleEntry 1 } -- 1.3.6.1.4.1.3715.17.2.3.1.2 scmObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object within the module." ::= { statusCodeModuleEntry 2 } -- 1.3.6.1.4.1.3715.17.2.3.1.3 scmObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The scmObjectDescriptor tells name, scale and unit of the object." ::= { statusCodeModuleEntry 3 } -- 1.3.6.1.4.1.3715.17.2.3.1.4 scmObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. See scdObjectDescriptor for format, example and usage. " ::= { statusCodeModuleEntry 4 } -- 1.3.6.1.4.1.3715.17.2.3.1.5 scmObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "See scdObjectAlarmValue for format, example and usage. " ::= { statusCodeModuleEntry 5 } -- 1.3.6.1.4.1.3715.17.2.4 statusCodeInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodeInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes monitorable objects per interface per module. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeInterfaceTable shall be used to obtains text definition of alarm." ::= { statusCode 4 } -- 1.3.6.1.4.1.3715.17.2.4.1 statusCodeInterfaceEntry OBJECT-TYPE SYNTAX StatusCodeInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sciObjectId } ::= { statusCodeInterfaceTable 1 } StatusCodeInterfaceEntry ::= SEQUENCE { sciInterfaceId INTEGER, sciObjectId Unsigned32, sciObjectValue INTEGER, sciObjectDescriptor DisplayString, sciObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.4.1.1 sciInterfaceId OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique interface Id within the module (e.g. RF connector number)." ::= { statusCodeInterfaceEntry 1 } -- 1.3.6.1.4.1.3715.17.2.4.1.2 sciObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object within the interface." ::= { statusCodeInterfaceEntry 2 } -- 1.3.6.1.4.1.3715.17.2.4.1.3 sciObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The sciObjectDescriptor tells name, scale and unit of the object." ::= { statusCodeInterfaceEntry 3 } -- 1.3.6.1.4.1.3715.17.2.4.1.4 sciObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. See scdObjectDescriptor for format, example and usage. " ::= { statusCodeInterfaceEntry 4 } -- 1.3.6.1.4.1.3715.17.2.4.1.5 sciObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "See dmObjectAlarmValue for format, example and usage. " ::= { statusCodeInterfaceEntry 5 } -- 1.3.6.1.4.1.3715.17.2.5 statusCodeTransportStreamTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodeTransportStreamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes monitorable objects of each transport stream. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeTransportStreamTable shall be used to obtains text definition of alarm." ::= { statusCode 5 } -- 1.3.6.1.4.1.3715.17.2.5.1 statusCodeTransportStreamEntry OBJECT-TYPE SYNTAX StatusCodeTransportStreamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, sctsObjectId } ::= { statusCodeTransportStreamTable 1 } StatusCodeTransportStreamEntry ::= SEQUENCE { sctsTransportStreamId INTEGER, sctsObjectId Unsigned32, sctsObjectValue INTEGER, sctsObjectDescriptor DisplayString, sctsObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.5.1.1 sctsTransportStreamId OBJECT-TYPE SYNTAX INTEGER (1..8192) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique transport stream id inside the interface." ::= { statusCodeTransportStreamEntry 1 } -- 1.3.6.1.4.1.3715.17.2.5.1.2 sctsObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object." ::= { statusCodeTransportStreamEntry 2 } -- 1.3.6.1.4.1.3715.17.2.5.1.3 sctsObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The sctsObjectDescriptor tells name, scale and unit of the object." ::= { statusCodeTransportStreamEntry 3 } -- 1.3.6.1.4.1.3715.17.2.5.1.4 sctsObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. See dmObjectDescriptor for format, example and usage. " ::= { statusCodeTransportStreamEntry 4 } -- 1.3.6.1.4.1.3715.17.2.5.1.5 sctsObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "See scdObjectAlarmValue for format, example and usage. " ::= { statusCodeTransportStreamEntry 5 } -- 1.3.6.1.4.1.3715.17.2.6 statusCodeServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodeServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes monitorable objects of each service. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeServiceTable shall be used to obtains text definition of alarm." ::= { statusCode 6 } -- 1.3.6.1.4.1.3715.17.2.6.1 statusCodeServiceEntry OBJECT-TYPE SYNTAX StatusCodeServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scsSID, scsObjectId } ::= { statusCodeServiceTable 1 } StatusCodeServiceEntry ::= SEQUENCE { scsSID INTEGER, scsObjectId Unsigned32, scsObjectValue INTEGER, scsObjectDescriptor DisplayString, scsServiceName DisplayString, scsObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.6.1.1 scsSID OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique service id number inside the transport stream." ::= { statusCodeServiceEntry 1 } -- 1.3.6.1.4.1.3715.17.2.6.1.2 scsObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object." ::= { statusCodeServiceEntry 2 } -- 1.3.6.1.4.1.3715.17.2.6.1.3 scsObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The scsObjectDescriptor tells name, scale and unit of the object." ::= { statusCodeServiceEntry 3 } -- 1.3.6.1.4.1.3715.17.2.6.1.4 scsObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. See scdObjectDescriptor for format, example and usage. " ::= { statusCodeServiceEntry 4 } -- 1.3.6.1.4.1.3715.17.2.6.1.5 scsServiceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the service." ::= { statusCodeServiceEntry 5 } -- 1.3.6.1.4.1.3715.17.2.6.1.6 scsObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "See scdObjectAlarmValue for format, example and usage. " ::= { statusCodeServiceEntry 6 } -- 1.3.6.1.4.1.3715.17.2.7 statusCodePidTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusCodePidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists monitorable objects of each PID. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodePidTable shall be used to obtains text definition of alarm." ::= { statusCode 7 } -- 1.3.6.1.4.1.3715.17.2.7.1 statusCodePidEntry OBJECT-TYPE SYNTAX StatusCodePidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scpPID, scpObjectId } ::= { statusCodePidTable 1 } StatusCodePidEntry ::= SEQUENCE { scpPID INTEGER, scpObjectId Unsigned32, scpObjectValue INTEGER, scpObjectDescriptor DisplayString, scpObjectAlarmValue INTEGER } -- 1.3.6.1.4.1.3715.17.2.7.1.1 scpPID OBJECT-TYPE SYNTAX INTEGER (0..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique PID value inside the transport stream." ::= { statusCodePidEntry 1 } -- 1.3.6.1.4.1.3715.17.2.7.1.2 scpObjectId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the monitorable object." ::= { statusCodePidEntry 2 } -- 1.3.6.1.4.1.3715.17.2.7.1.3 scpObjectValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the monitorable object. The scpObjectDescriptor tells name, scale and unit of the object." ::= { statusCodePidEntry 3 } -- 1.3.6.1.4.1.3715.17.2.7.1.4 scpObjectDescriptor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the monitorable object. See scdObjectDescriptor for format, example and usage. " ::= { statusCodePidEntry 4 } -- 1.3.6.1.4.1.3715.17.2.7.1.5 scpObjectAlarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "See scdObjectAlarmValue for format, example and usage. " ::= { statusCodePidEntry 5 } -- 1.3.6.1.4.1.3715.17.3 interface OBJECT IDENTIFIER ::= { luminato 3 } -- 1.3.6.1.4.1.3715.17.3.1 ifExtTable OBJECT-TYPE SYNTAX SEQUENCE OF IfExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 1 } -- 1.3.6.1.4.1.3715.17.3.1.1 ifExtEntry OBJECT-TYPE SYNTAX IfExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { INTEGER } ::= { ifExtTable 1 } IfExtEntry ::= SEQUENCE { ifExtIndex INTEGER, ifExtName DisplayString, ifExtModule INTEGER, ifExtPhysInterface INTEGER, ifExtLogiInterface INTEGER, ifExtDirection INTEGER } -- 1.3.6.1.4.1.3715.17.3.1.1.1 ifExtIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique index for an interface. The index is of following format: SDPPVVVV, where: - S = Slot number - D = input(1) / output(2) - PP = Physical interface number - VVVV = Virtual interface number" ::= { ifExtEntry 1 } -- 1.3.6.1.4.1.3715.17.3.1.1.2 ifExtName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description for the interface." ::= { ifExtEntry 2 } -- 1.3.6.1.4.1.3715.17.3.1.1.3 ifExtModule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the physical module or slot housing the interface." ::= { ifExtEntry 3 } -- 1.3.6.1.4.1.3715.17.3.1.1.4 ifExtPhysInterface OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Physical interface number." ::= { ifExtEntry 4 } -- 1.3.6.1.4.1.3715.17.3.1.1.5 ifExtLogiInterface OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Logical interface number." ::= { ifExtEntry 5 } -- 1.3.6.1.4.1.3715.17.3.1.1.6 ifExtDirection OBJECT-TYPE SYNTAX INTEGER { input(1), output(2), both(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Direction for the data going through the interface." ::= { ifExtEntry 6 } -- Signal physical level -- 1.3.6.1.4.1.3715.17.3.2 signalPhysTable OBJECT-TYPE SYNTAX SEQUENCE OF SignalPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 2 } -- 1.3.6.1.4.1.3715.17.3.2.1 signalPhysEntry OBJECT-TYPE SYNTAX SignalPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifExtIndex } ::= { signalPhysTable 1 } SignalPhysEntry ::= SEQUENCE { signalSnr INTEGER, signalSnrMin INTEGER, signalSnrMax INTEGER, signalCcErrors INTEGER, signalBer Float, signalVber Float } -- 1.3.6.1.4.1.3715.17.3.2.1.2 signalSnr OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Recent signal to noise ratio in 1/10th of dB." ::= { signalPhysEntry 2 } -- 1.3.6.1.4.1.3715.17.3.2.1.3 signalSnrMin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Lowest measured SNR value since last device startup or last counter reset." ::= { signalPhysEntry 3 } -- 1.3.6.1.4.1.3715.17.3.2.1.4 signalSnrMax OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Highest measured SNR value since last device startup or last counter reset." ::= { signalPhysEntry 4 } -- 1.3.6.1.4.1.3715.17.3.2.1.5 signalCcErrors OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number of continuity errors since last device startup or last counter reset." ::= { signalPhysEntry 5 } -- 1.3.6.1.4.1.3715.17.3.2.1.6 signalBer OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Calculated bit error ratio of the signal." ::= { signalPhysEntry 6 } -- 1.3.6.1.4.1.3715.17.3.2.1.7 signalVber OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Calculated Viterbi bit error ratio of the signal." ::= { signalPhysEntry 7 } -- transfer statistics -- 1.3.6.1.4.1.3715.17.3.3 transferTable OBJECT-TYPE SYNTAX SEQUENCE OF TransferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 3 } -- 1.3.6.1.4.1.3715.17.3.3.1 transferEntry OBJECT-TYPE SYNTAX TransferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifExtIndex } ::= { transferTable 1 } TransferEntry ::= SEQUENCE { transBitrate INTEGER, transBitrateMin INTEGER, transBitrateMax INTEGER } -- 1.3.6.1.4.1.3715.17.3.3.1.2 transBitrate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Recent measured bitrate of the interface in kilobits per second." ::= { transferEntry 2 } -- 1.3.6.1.4.1.3715.17.3.3.1.3 transBitrateMin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Lowest measured bitrate since last device startup or last counter reset. Writing clears the counter." ::= { transferEntry 3 } -- 1.3.6.1.4.1.3715.17.3.3.1.4 transBitrateMax OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Highest measured bitrate since last device startup or last counter reset. Writing clears the counter." ::= { transferEntry 4 } -- ProMpegFec interface related data -- 1.3.6.1.4.1.3715.17.3.20 proMpegFecTable OBJECT-TYPE SYNTAX SEQUENCE OF ProMpegFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 20 } -- 1.3.6.1.4.1.3715.17.3.20.1 proMpegFecEntry OBJECT-TYPE SYNTAX ProMpegFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifExtIndex } ::= { proMpegFecTable 1 } ProMpegFecEntry ::= SEQUENCE { fecValidPkts Counter32, fecUncorrectedPkts Counter32, fecCorrectedPkts Counter32, fecDuplicatePkts Counter32, fecReorderedPkts Counter32, fecIncorrectSeqNumbers Counter32, fecDiscontinuities Counter32 } -- 1.3.6.1.4.1.3715.17.3.20.1.1 fecValidPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of media stream packets received. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 1 } -- 1.3.6.1.4.1.3715.17.3.20.1.2 fecUncorrectedPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of missing media stream packets after FEC decoding. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 2 } -- 1.3.6.1.4.1.3715.17.3.20.1.3 fecCorrectedPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of corrected packets after FEC decoding. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 3 } -- 1.3.6.1.4.1.3715.17.3.20.1.4 fecDuplicatePkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of duplicate packets received. Defined as a received packet with the same RTP sequence number as any of the packets already in the decoding buffer. All duplicate packets are automatically discarded and do not cause missing packets or duplicates to the output stream. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 4 } -- 1.3.6.1.4.1.3715.17.3.20.1.5 fecReorderedPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of reordered packets received. Defined as a received packet which RTP sequence number is smaller than the highest RTP sequence number already received, excluding duplicate packets and packets which are out of the decoding buffer range. These packets will be re-ordered and do not cause missing packets to the output stream. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 5 } -- 1.3.6.1.4.1.3715.17.3.20.1.6 fecIncorrectSeqNumbers OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of received media packets that have RTP sequence number out of decoding buffer range. All these packet are discarded. If 10 consecutive packets are out of range then decoding buffer is flushed and re-initialised i.e. all packets in the buffer are discarded. Incorrect sequence numbers counter will not be incremented if decoding buffer has been flushed. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 6 } -- 1.3.6.1.4.1.3715.17.3.20.1.7 fecDiscontinuities OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of RTP sequence number discontinuities after FEC decoding. Discontinuity is detected when the sequence number of received RTP packet (after decoding) is not equal to sequence number of previous packet. Discontinuities are typically detected when there are uncorrected packets in the stream, or when there are brief interruptions in the stream (in range of about 1-20 seconds). Also abrupt change of stream source will be counted as discontinuity because of jump in RTP sequence numbers. Writing any value in this oid will clear all ProMpegFec related counters on the current interface." ::= { proMpegFecEntry 7 } -- Input service information -- 1.3.6.1.4.1.3715.17.3.4 inputServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF InputServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 4 } -- 1.3.6.1.4.1.3715.17.3.4.1 inputServiceEntry OBJECT-TYPE SYNTAX InputServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifExtIndex } ::= { inputServiceTable 1 } InputServiceEntry ::= SEQUENCE { iSID INTEGER, iServiceName DisplayString, iServiceBitrate INTEGER } -- 1.3.6.1.4.1.3715.17.3.4.1.2 iSID OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique service id number inside the transport stream." ::= { inputServiceEntry 2 } -- 1.3.6.1.4.1.3715.17.3.4.1.3 iServiceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the service." ::= { inputServiceEntry 3 } -- 1.3.6.1.4.1.3715.17.3.4.1.4 iServiceBitrate OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The bitrate of service" ::= { inputServiceEntry 4 } -- Output service information -- 1.3.6.1.4.1.3715.17.3.5 outputServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF OutputServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { interface 5 } -- 1.3.6.1.4.1.3715.17.3.5.1 outputServiceEntry OBJECT-TYPE SYNTAX OutputServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifExtIndex } ::= { outputServiceTable 1 } OutputServiceEntry ::= SEQUENCE { oSID INTEGER, oServiceName DisplayString, oServiceBitrate INTEGER } -- 1.3.6.1.4.1.3715.17.3.5.1.2 oSID OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique service id number inside the transport stream." ::= { outputServiceEntry 2 } -- 1.3.6.1.4.1.3715.17.3.5.1.2 oServiceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the service." ::= { outputServiceEntry 3 } -- 1.3.6.1.4.1.3715.17.3.5.1.3 oServiceBitrate OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The bitrate of service" ::= { outputServiceEntry 4 } ---------------------------------------------------------------------- -- 1.3.6.1.4.1.3715.17.4 notifications OBJECT IDENTIFIER ::= { luminato 4 } -- 1.3.6.1.4.1.3715.17.5 statusFlags OBJECT IDENTIFIER ::= { luminato 5 } -- 1.3.6.1.4.1.3715.17.5.2 moduleStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { statusFlags 2 } -- 1.3.6.1.4.1.3715.17.5.2.1 moduleStatusEntry OBJECT-TYPE SYNTAX ModuleStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { moduleId } ::= { moduleStatusTable 1 } ModuleStatusEntry ::= SEQUENCE { moduleId INTEGER, modulePidConflictStatus INTEGER, moduleTemperatureHigh INTEGER, moduleTemperatureLow INTEGER, modulePidCapaStatus INTEGER, modulePsisiCaptureCapaStatus INTEGER, moduleSidAllocStatus INTEGER, moduleCaDetectStatus INTEGER, moduleDetectStatus INTEGER, moduleVoltageHigh INTEGER, moduleVoltageLow INTEGER, moduleCurrentHigh INTEGER, moduleCurrentLow INTEGER, moduleDaemonInitStatus INTEGER, moduleDriverStatus INTEGER, moduleHwStatus INTEGER, moduleFanStatus INTEGER, modulePowerSourceStatus INTEGER, modulePsuOverloadStatus INTEGER, moduleBootupProgressStatus INTEGER, moduleBootupRetryStatus INTEGER, moduleBootupStatus INTEGER, moduleShutdownProgressStatus INTEGER, moduleConnStatus INTEGER, moduleCompatStatus INTEGER, moduleUpcPowerLow INTEGER, moduleUpcPowerHigh INTEGER, moduleCalibrDataStatus INTEGER, moduleCalibrDataCheckStatus INTEGER, moduleDescrStatus INTEGER, moduleBackupStatus INTEGER, moduleNitOutputsStatus INTEGER, moduleNitSelectionStatus INTEGER, moduleNitConfChangeStatus INTEGER, moduleNitDataQueryStatus INTEGER, moduleNitWizardStatus INTEGER, moduleQamFreqStatus INTEGER, moduleOutputSidStatus INTEGER, moduleConfStatus INTEGER, moduleFreqStatus INTEGER, moduleOutputPowerStatus INTEGER, moduleSymrateStatus INTEGER, moduleChanDistStatus INTEGER, moduleLnbVoltStatus INTEGER, moduleFecRateStatus INTEGER, moduleLnbCurrStatus INTEGER, moduleFreqOffsetStatus INTEGER, moduleDescrRestartStatus INTEGER, moduleCamRestartStatus INTEGER, moduleEcmgStatus INTEGER, moduleEcmStreamStatus INTEGER, moduleEmmStatus INTEGER, moduleEmmStreamStatus INTEGER, moduleEcmgConnStatus INTEGER, moduleEmmConnStatus INTEGER, moduleEcmgSpareStatus INTEGER, moduleBootloaderAvailStatus INTEGER, moduleBl1UpdateProgStatus INTEGER, moduleBl2UpdateProgStatus INTEGER, moduleBl1UpdateStatus INTEGER, moduleBl2UpdateStatus INTEGER, moduleActiveBackupStatus INTEGER, moduleConfProgressStatus INTEGER, modulePresenceStatus INTEGER, moduleProcessRestartStatus INTEGER, moduleBackupLicenseStatus INTEGER, modulePsisiEditorLicenseStatus INTEGER, moduleMuxLicenseStatus INTEGER, moduleDemuxLicenseStatus INTEGER, moduleDvbLicenseStatus INTEGER, moduleMsdLicenseStatus INTEGER, moduleDvbs2LicenseStatus INTEGER, moduleDvbt2LicenseStatus INTEGER, moduleScsLicenseStatus INTEGER, moduleCliLoginStatus INTEGER, moduleRedunActivationStatus INTEGER, moduleExtioPinSignalingStatus INTEGER, moduleBackupPsuStatus INTEGER, moduleIntrusionStatus INTEGER, moduleRedunStatus INTEGER, moduleBackupHwStatus INTEGER, moduleSwUpdateProgress INTEGER, moduleSwUpdateStatus INTEGER, moduleEitLicenseStatus INTEGER, moduleDescramblingStatus INTEGER, moduleDvbTimeStatus INTEGER, moduleTunerDcFeedStatus INTEGER, moduleTunerPlpSelectionReqStatus INTEGER, moduleTunerPlpStatus INTEGER, moduleTunerHierarchyStatus INTEGER, moduleEcmStatus INTEGER, moduleScramConflictStatus INTEGER, moduleScramSharedStatus INTEGER, moduleBackupVoltageHigh INTEGER, moduleBackupVoltageLow INTEGER, moduleSdtTableStatus INTEGER, moduleDescramblingRestart INTEGER, moduleCaModuleRestart INTEGER, moduleCaMenuStatus INTEGER, moduleInvalidCamRouting INTEGER, moduleNitSidConflict INTEGER, moduleLicenseMissingFEC INTEGER, moduleFecCorrectionStatus INTEGER, moduleFecPacketDropStatus INTEGER, moduleFecMediaPktsStatus INTEGER, moduleSfpLinkStatus INTEGER, moduleBackupSyncModeOff INTEGER, moduleBackupSyncModeManual INTEGER, moduleBackupSyncModeAuto INTEGER, moduleBackupSyncConfStatus INTEGER, moduleBackupSyncStatus INTEGER, moduleBackupSyncSwCompatibility INTEGER, moduleBackupSyncHwCompatibility INTEGER, moduleBackupSyncConfFaultStatus INTEGER, moduleBackupSyncConnectionStatus INTEGER, moduleBackupSyncFromBackupStatus INTEGER, moduleBackupSyncRebootStatus INTEGER, moduleBackupSyncLicenseCompatStatus INTEGER, moduleBackupSyncLicenseCompareStatus INTEGER, moduleDeviceFirstBootStatus INTEGER, modulePartitionConfigurationBackup INTEGER, modulePartitionConfigurationRestore INTEGER, moduleSwRevertStatus INTEGER, moduleMaxOutputPidsStatus INTEGER, moduleUserRebootStatus INTEGER, moduleRemovalStatus INTEGER, moduleInsertionStatus INTEGER, moduleSptsInputConfStatus INTEGER } -- 1.3.6.1.4.1.3715.17.5.2.1.1 moduleId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module identifier" ::= { moduleStatusEntry 1 } -- 1.3.6.1.4.1.3715.17.5.2.1.4 modulePidConflictStatus OBJECT-TYPE SYNTAX INTEGER { pidOk(1), pidConflict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "PID conflict status" ::= { moduleStatusEntry 4 } -- 1.3.6.1.4.1.3715.17.5.2.1.6 moduleTemperatureHigh OBJECT-TYPE SYNTAX INTEGER { temperatureNominal(1), temperatureHigh(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "High temperature status" ::= { moduleStatusEntry 6 } -- 1.3.6.1.4.1.3715.17.5.2.1.7 moduleTemperatureLow OBJECT-TYPE SYNTAX INTEGER { temperatureNominal(1), temperatureLow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Low temperature status" ::= { moduleStatusEntry 7 } -- 1.3.6.1.4.1.3715.17.5.2.1.4104 modulePidCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module PID capacity status" ::= { moduleStatusEntry 4104 } -- 1.3.6.1.4.1.3715.17.5.2.1.4105 modulePsisiCaptureCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module PSI/SI table capture capacity status" ::= { moduleStatusEntry 4105 } -- 1.3.6.1.4.1.3715.17.5.2.1.4106 moduleSidAllocStatus OBJECT-TYPE SYNTAX INTEGER { sidAllocOk(1), sidAllocCapaExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module service ID allocation capacity status" ::= { moduleStatusEntry 4106 } -- 1.3.6.1.4.1.3715.17.5.2.1.4108 moduleCaDetectStatus OBJECT-TYPE SYNTAX INTEGER { moduleOk(1), moduleMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "CA module detection status" ::= { moduleStatusEntry 4108 } -- 1.3.6.1.4.1.3715.17.5.2.1.4111 moduleDetectStatus OBJECT-TYPE SYNTAX INTEGER { moduleOk(1), moduleUnknown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module detection status" ::= { moduleStatusEntry 4111 } -- 1.3.6.1.4.1.3715.17.5.2.1.4112 moduleVoltageHigh OBJECT-TYPE SYNTAX INTEGER { voltageNominal(1), voltageHigh(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "High voltage status" ::= { moduleStatusEntry 4112 } -- 1.3.6.1.4.1.3715.17.5.2.1.4113 moduleVoltageLow OBJECT-TYPE SYNTAX INTEGER { voltageNominal(1), voltageLow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Low voltage status" ::= { moduleStatusEntry 4113 } -- 1.3.6.1.4.1.3715.17.5.2.1.4114 moduleCurrentHigh OBJECT-TYPE SYNTAX INTEGER { currentNominal(1), currentHigh(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "High current status" ::= { moduleStatusEntry 4114 } -- 1.3.6.1.4.1.3715.17.5.2.1.4115 moduleCurrentLow OBJECT-TYPE SYNTAX INTEGER { currentNominal(1), currentLow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Low current status" ::= { moduleStatusEntry 4115 } -- 1.3.6.1.4.1.3715.17.5.2.1.4127 moduleDaemonInitStatus OBJECT-TYPE SYNTAX INTEGER { daemonNominal(1), daemonInitFailed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module daemon initialization status" ::= { moduleStatusEntry 4127 } -- 1.3.6.1.4.1.3715.17.5.2.1.4129 moduleDriverStatus OBJECT-TYPE SYNTAX INTEGER { driverNominal(1), driverFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module device driver status" ::= { moduleStatusEntry 4129 } -- 1.3.6.1.4.1.3715.17.5.2.1.4130 moduleHwStatus OBJECT-TYPE SYNTAX INTEGER { hwNominal(1), hwFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module hardware status" ::= { moduleStatusEntry 4130 } -- 1.3.6.1.4.1.3715.17.5.2.1.4131 moduleFanStatus OBJECT-TYPE SYNTAX INTEGER { fanNominal(1), fanFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fan status" ::= { moduleStatusEntry 4131 } -- 1.3.6.1.4.1.3715.17.5.2.1.4132 modulePowerSourceStatus OBJECT-TYPE SYNTAX INTEGER { runningOnMainPower(1), runningOnBackupPower(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power source status" ::= { moduleStatusEntry 4132 } -- 1.3.6.1.4.1.3715.17.5.2.1.4133 modulePsuOverloadStatus OBJECT-TYPE SYNTAX INTEGER { psuNominal(1), psuOverloaded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply overload status" ::= { moduleStatusEntry 4133 } -- 1.3.6.1.4.1.3715.17.5.2.1.4134 moduleBootupProgressStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleBootingUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootup progress" ::= { moduleStatusEntry 4134 } -- 1.3.6.1.4.1.3715.17.5.2.1.4135 moduleBootupRetryStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleBootingRetrying(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootup retry status" ::= { moduleStatusEntry 4135 } -- 1.3.6.1.4.1.3715.17.5.2.1.4136 moduleBootupStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleBootFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootup status" ::= { moduleStatusEntry 4136 } -- 1.3.6.1.4.1.3715.17.5.2.1.4137 moduleShutdownProgressStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleShuttingDown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module shutdown progress" ::= { moduleStatusEntry 4137 } -- 1.3.6.1.4.1.3715.17.5.2.1.4138 moduleConnStatus OBJECT-TYPE SYNTAX INTEGER { connectionNominal(1), connectionLost(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module connection status" ::= { moduleStatusEntry 4138 } -- 1.3.6.1.4.1.3715.17.5.2.1.4139 moduleCompatStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleIncompatible(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module compatibility status" ::= { moduleStatusEntry 4139 } -- 1.3.6.1.4.1.3715.17.5.2.1.4147 moduleUpcPowerLow OBJECT-TYPE SYNTAX INTEGER { ucpPowerNominal(1), ucpPowerLow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module UPC input power low status" ::= { moduleStatusEntry 4147 } -- 1.3.6.1.4.1.3715.17.5.2.1.4148 moduleUpcPowerHigh OBJECT-TYPE SYNTAX INTEGER { ucpPowerNominal(1), ucpPowerHigh(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module UPC input power high status" ::= { moduleStatusEntry 4148 } -- 1.3.6.1.4.1.3715.17.5.2.1.4149 moduleCalibrDataStatus OBJECT-TYPE SYNTAX INTEGER { calibrationDataNominal(1), calibrationDataMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module calibration data status" ::= { moduleStatusEntry 4149 } -- 1.3.6.1.4.1.3715.17.5.2.1.4150 moduleCalibrDataCheckStatus OBJECT-TYPE SYNTAX INTEGER { checkOk(1), checkSkipped(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module calibration data check status" ::= { moduleStatusEntry 4150 } -- 1.3.6.1.4.1.3715.17.5.2.1.4151 moduleDescrStatus OBJECT-TYPE SYNTAX INTEGER { descramblingOk(1), descramblingFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module descrambling status" ::= { moduleStatusEntry 4151 } -- 1.3.6.1.4.1.3715.17.5.2.1.4153 moduleBackupStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleSwitchedToBackup(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module backup status" ::= { moduleStatusEntry 4153 } -- 1.3.6.1.4.1.3715.17.5.2.1.4154 moduleNitOutputsStatus OBJECT-TYPE SYNTAX INTEGER { nitOutputsNominal(1), noSupportedNitOutputs(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported Nit output module status" ::= { moduleStatusEntry 4154 } -- 1.3.6.1.4.1.3715.17.5.2.1.4155 moduleNitSelectionStatus OBJECT-TYPE SYNTAX INTEGER { nitSelectionNominal(1), noSelectedNitOutputs(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Nit output selection status" ::= { moduleStatusEntry 4155 } -- 1.3.6.1.4.1.3715.17.5.2.1.4156 moduleNitConfChangeStatus OBJECT-TYPE SYNTAX INTEGER { nitConfNominal(1), nitConfChanged(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Nit configuration change status" ::= { moduleStatusEntry 4156 } -- 1.3.6.1.4.1.3715.17.5.2.1.4157 moduleNitDataQueryStatus OBJECT-TYPE SYNTAX INTEGER { nitDataQueryNominal(1), nitDataQueryFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Nit data query status" ::= { moduleStatusEntry 4157 } -- 1.3.6.1.4.1.3715.17.5.2.1.4158 moduleNitWizardStatus OBJECT-TYPE SYNTAX INTEGER { nitWizardNominal(1), nitWizardFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Nit wizard status" ::= { moduleStatusEntry 4158 } -- 1.3.6.1.4.1.3715.17.5.2.1.4159 moduleQamFreqStatus OBJECT-TYPE SYNTAX INTEGER { qamFreqUnique(1), qamFreqDuplicate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "QAM output unique frequency status" ::= { moduleStatusEntry 4159 } -- 1.3.6.1.4.1.3715.17.5.2.1.4173 moduleOutputSidStatus OBJECT-TYPE SYNTAX INTEGER { sidOk(1), sidConflict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module output SID status" ::= { moduleStatusEntry 4173 } -- 1.3.6.1.4.1.3715.17.5.2.1.4175 moduleConfStatus OBJECT-TYPE SYNTAX INTEGER { configurationOk(1), configurationUnsupported(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module configuration status" ::= { moduleStatusEntry 4175 } -- 1.3.6.1.4.1.3715.17.5.2.1.4176 moduleFreqStatus OBJECT-TYPE SYNTAX INTEGER { freqOk(1), freqOutOfRange(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module frequency configuration range status" ::= { moduleStatusEntry 4176 } -- 1.3.6.1.4.1.3715.17.5.2.1.4177 moduleOutputPowerStatus OBJECT-TYPE SYNTAX INTEGER { powerOk(1), powerOutOfRange(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module output power status" ::= { moduleStatusEntry 4177 } -- 1.3.6.1.4.1.3715.17.5.2.1.4178 moduleSymrateStatus OBJECT-TYPE SYNTAX INTEGER { symbolRateOk(1), symbolRateOutOfRange(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module symbol rate configuration status" ::= { moduleStatusEntry 4178 } -- 1.3.6.1.4.1.3715.17.5.2.1.4179 moduleChanDistStatus OBJECT-TYPE SYNTAX INTEGER { chanDistOk(1), chanDistTooNarrow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module channel distance configuration status" ::= { moduleStatusEntry 4179 } -- 1.3.6.1.4.1.3715.17.5.2.1.4180 moduleLnbVoltStatus OBJECT-TYPE SYNTAX INTEGER { lnbVoltageOk(1), lnbVoltageInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module LNB voltage configuration status" ::= { moduleStatusEntry 4180 } -- 1.3.6.1.4.1.3715.17.5.2.1.4181 moduleFecRateStatus OBJECT-TYPE SYNTAX INTEGER { fecRateOk(1), fecRateInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module FEC rate configuration vs modulation status" ::= { moduleStatusEntry 4181 } -- 1.3.6.1.4.1.3715.17.5.2.1.4182 moduleLnbCurrStatus OBJECT-TYPE SYNTAX INTEGER { lnbCurrentOk(1), lnbCurrentInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module LNB current status" ::= { moduleStatusEntry 4182 } -- 1.3.6.1.4.1.3715.17.5.2.1.4183 moduleFreqOffsetStatus OBJECT-TYPE SYNTAX INTEGER { freqOffsetOk(1), freqOffsetInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module frequency offset configuration status" ::= { moduleStatusEntry 4183 } -- 1.3.6.1.4.1.3715.17.5.2.1.4185 moduleDescrRestartStatus OBJECT-TYPE SYNTAX INTEGER { descramblingNominal(1), descramblingRestarting(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module descrambling restart status" ::= { moduleStatusEntry 4185 } -- 1.3.6.1.4.1.3715.17.5.2.1.4186 moduleCamRestartStatus OBJECT-TYPE SYNTAX INTEGER { camNominal(1), camRestarting(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module CAM restart status" ::= { moduleStatusEntry 4186 } -- 1.3.6.1.4.1.3715.17.5.2.1.4187 moduleEcmgStatus OBJECT-TYPE SYNTAX INTEGER { ecmgNominal(1), ecmgFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ecmg status" ::= { moduleStatusEntry 4187 } -- 1.3.6.1.4.1.3715.17.5.2.1.4188 moduleEcmStreamStatus OBJECT-TYPE SYNTAX INTEGER { ecmStreamNominal(1), ecmStreamFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ecm stream status" ::= { moduleStatusEntry 4188 } -- 1.3.6.1.4.1.3715.17.5.2.1.4189 moduleEmmStatus OBJECT-TYPE SYNTAX INTEGER { emmNominal(1), emmFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Emm status" ::= { moduleStatusEntry 4189 } -- 1.3.6.1.4.1.3715.17.5.2.1.4190 moduleEmmStreamStatus OBJECT-TYPE SYNTAX INTEGER { emmStreamNominal(1), emmStreamFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Emm stream status" ::= { moduleStatusEntry 4190 } -- 1.3.6.1.4.1.3715.17.5.2.1.4191 moduleEcmgConnStatus OBJECT-TYPE SYNTAX INTEGER { ecmgConnNominal(1), ecmgNotConnected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ecmg connection status" ::= { moduleStatusEntry 4191 } -- 1.3.6.1.4.1.3715.17.5.2.1.4192 moduleEmmConnStatus OBJECT-TYPE SYNTAX INTEGER { emmConnNominal(1), emmNotConnected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Emm connection status" ::= { moduleStatusEntry 4192 } -- 1.3.6.1.4.1.3715.17.5.2.1.4194 moduleEcmgSpareStatus OBJECT-TYPE SYNTAX INTEGER { ecmgNominal(1), ecmgSwitchedToSpare(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ecmg spare connection status" ::= { moduleStatusEntry 4194 } -- 1.3.6.1.4.1.3715.17.5.2.1.4195 moduleBootloaderAvailStatus OBJECT-TYPE SYNTAX INTEGER { bootloaderOk(1), bootloaderObsolete(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader availability status" ::= { moduleStatusEntry 4195 } -- 1.3.6.1.4.1.3715.17.5.2.1.4196 moduleBl1UpdateProgStatus OBJECT-TYPE SYNTAX INTEGER { bootloaderNominal(1), bootloaderUpdating(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader update progress" ::= { moduleStatusEntry 4196 } -- 1.3.6.1.4.1.3715.17.5.2.1.4197 moduleBl2UpdateProgStatus OBJECT-TYPE SYNTAX INTEGER { bootloaderNominal(1), bootloaderUpdating(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader update progress" ::= { moduleStatusEntry 4197 } -- 1.3.6.1.4.1.3715.17.5.2.1.4198 moduleBl1UpdateStatus OBJECT-TYPE SYNTAX INTEGER { bootloaderNominal(1), bootloaderUpdateFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader update status" ::= { moduleStatusEntry 4198 } -- 1.3.6.1.4.1.3715.17.5.2.1.4199 moduleBl2UpdateStatus OBJECT-TYPE SYNTAX INTEGER { bootloaderNominal(1), bootloaderUpdateFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module bootloader update status" ::= { moduleStatusEntry 4199 } -- 1.3.6.1.4.1.3715.17.5.2.1.4203 moduleActiveBackupStatus OBJECT-TYPE SYNTAX INTEGER { backupPassive(1), backupActive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup module status" ::= { moduleStatusEntry 4203 } -- 1.3.6.1.4.1.3715.17.5.2.1.4205 moduleConfProgressStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleConfiguring(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module configuration progress" ::= { moduleStatusEntry 4205 } -- 1.3.6.1.4.1.3715.17.5.2.1.4206 modulePresenceStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), noModule(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module presence progress" ::= { moduleStatusEntry 4206 } -- 1.3.6.1.4.1.3715.17.5.2.1.4208 moduleProcessRestartStatus OBJECT-TYPE SYNTAX INTEGER { processesNominal(1), processRestarted(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Process restart status" ::= { moduleStatusEntry 4208 } -- 1.3.6.1.4.1.3715.17.5.2.1.4209 moduleBackupLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup license status" ::= { moduleStatusEntry 4209 } -- 1.3.6.1.4.1.3715.17.5.2.1.4210 modulePsisiEditorLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "PSI/SI editor license status" ::= { moduleStatusEntry 4210 } -- 1.3.6.1.4.1.3715.17.5.2.1.4211 moduleMuxLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Multiplexing license status" ::= { moduleStatusEntry 4211 } -- 1.3.6.1.4.1.3715.17.5.2.1.4212 moduleDemuxLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Demultiplexing license status" ::= { moduleStatusEntry 4212 } -- 1.3.6.1.4.1.3715.17.5.2.1.4213 moduleDvbLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "DVB processing license status" ::= { moduleStatusEntry 4213 } -- 1.3.6.1.4.1.3715.17.5.2.1.4214 moduleMsdLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "MSD license status" ::= { moduleStatusEntry 4214 } -- 1.3.6.1.4.1.3715.17.5.2.1.4215 moduleDvbs2LicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "DVB-S2 processing license status" ::= { moduleStatusEntry 4215 } -- 1.3.6.1.4.1.3715.17.5.2.1.4216 moduleDvbt2LicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "DVB-T2 processing license status" ::= { moduleStatusEntry 4216 } -- 1.3.6.1.4.1.3715.17.5.2.1.4217 moduleScsLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseValid(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Scs license status" ::= { moduleStatusEntry 4217 } -- 1.3.6.1.4.1.3715.17.5.2.1.4218 moduleCliLoginStatus OBJECT-TYPE SYNTAX INTEGER { cliNotLoggedIn(1), cliLoggedIn(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "CLI login status" ::= { moduleStatusEntry 4218 } -- 1.3.6.1.4.1.3715.17.5.2.1.4222 moduleRedunActivationStatus OBJECT-TYPE SYNTAX INTEGER { redundancyPassive(1), redundancyActivated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Redundancy activation status" ::= { moduleStatusEntry 4222 } -- 1.3.6.1.4.1.3715.17.5.2.1.4223 moduleExtioPinSignalingStatus OBJECT-TYPE SYNTAX INTEGER { extioPinNominal(1), extioPinSignaled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "EXT-IO pin status" ::= { moduleStatusEntry 4223 } -- 1.3.6.1.4.1.3715.17.5.2.1.4224 moduleBackupPsuStatus OBJECT-TYPE SYNTAX INTEGER { backupPsuNominal(1), backupPsuFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup power supply status" ::= { moduleStatusEntry 4224 } -- 1.3.6.1.4.1.3715.17.5.2.1.4225 moduleIntrusionStatus OBJECT-TYPE SYNTAX INTEGER { intrusionNominal(1), intrusionDetected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Intrusion detection status" ::= { moduleStatusEntry 4225 } -- 1.3.6.1.4.1.3715.17.5.2.1.4227 moduleRedunStatus OBJECT-TYPE SYNTAX INTEGER { redundancyOk(1), redundancyFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Redundancy status" ::= { moduleStatusEntry 4227 } -- 1.3.6.1.4.1.3715.17.5.2.1.4230 moduleBackupHwStatus OBJECT-TYPE SYNTAX INTEGER { backupHwOk(1), backupHwNotSupported(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware backup support status" ::= { moduleStatusEntry 4230 } -- 1.3.6.1.4.1.3715.17.5.2.1.4231 moduleSwUpdateProgress OBJECT-TYPE SYNTAX INTEGER { swUpdateInactive(1), swUpdateInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Software update progress" ::= { moduleStatusEntry 4231 } -- 1.3.6.1.4.1.3715.17.5.2.1.4233 moduleSwUpdateStatus OBJECT-TYPE SYNTAX INTEGER { swNominal(1), swUpdateFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Software update status" ::= { moduleStatusEntry 4233 } -- 1.3.6.1.4.1.3715.17.5.2.1.4235 moduleEitLicenseStatus OBJECT-TYPE SYNTAX INTEGER { licenseValid(1), notLicensed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "EIT license status" ::= { moduleStatusEntry 4235 } -- 1.3.6.1.4.1.3715.17.5.2.1.4237 moduleDescramblingStatus OBJECT-TYPE SYNTAX INTEGER { descramblingNominal(1), descramblingFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Descrambling status" ::= { moduleStatusEntry 4237 } -- 1.3.6.1.4.1.3715.17.5.2.1.4243 moduleDvbTimeStatus OBJECT-TYPE SYNTAX INTEGER { dvbTimeNominal(1), dvbTimeMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "DVB time detection status" ::= { moduleStatusEntry 4243 } -- 1.3.6.1.4.1.3715.17.5.2.1.4245 moduleTunerDcFeedStatus OBJECT-TYPE SYNTAX INTEGER { currentNominal(1), currentOutOfRange(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Tuner DC feed current status" ::= { moduleStatusEntry 4245 } -- 1.3.6.1.4.1.3715.17.5.2.1.4247 moduleTunerPlpSelectionReqStatus OBJECT-TYPE SYNTAX INTEGER { plpSelectionOk(1), plpSelectionRequired(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Tuner data PLP ID requirement status" ::= { moduleStatusEntry 4247 } -- 1.3.6.1.4.1.3715.17.5.2.1.4248 moduleTunerPlpStatus OBJECT-TYPE SYNTAX INTEGER { plpSelectionValid(1), plpSelectionNotValid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Tuner data PLP ID validity status" ::= { moduleStatusEntry 4248 } -- 1.3.6.1.4.1.3715.17.5.2.1.4249 moduleTunerHierarchyStatus OBJECT-TYPE SYNTAX INTEGER { hierarchyOk(1), hierarchyInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of transmission hierarchy" ::= { moduleStatusEntry 4249 } -- 1.3.6.1.4.1.3715.17.5.2.1.4250 moduleEcmStatus OBJECT-TYPE SYNTAX INTEGER { ecmNominal(1), ecmMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "ECM stream connection status" ::= { moduleStatusEntry 4250 } -- 1.3.6.1.4.1.3715.17.5.2.1.4251 moduleScramConflictStatus OBJECT-TYPE SYNTAX INTEGER { scramblingNominal(1), scramblingConflict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module scrambling shared component conflict status" ::= { moduleStatusEntry 4251 } -- 1.3.6.1.4.1.3715.17.5.2.1.4252 moduleScramSharedStatus OBJECT-TYPE SYNTAX INTEGER { scramblingNominal(1), scramblingSharedComponent(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module scrambling shared component status" ::= { moduleStatusEntry 4252 } -- 1.3.6.1.4.1.3715.17.5.2.1.4253 moduleBackupVoltageHigh OBJECT-TYPE SYNTAX INTEGER { voltageNominal(1), voltageHigh(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup high voltage status" ::= { moduleStatusEntry 4253 } -- 1.3.6.1.4.1.3715.17.5.2.1.4254 moduleBackupVoltageLow OBJECT-TYPE SYNTAX INTEGER { voltageNominal(1), voltageLow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup low voltage status" ::= { moduleStatusEntry 4254 } -- 1.3.6.1.4.1.3715.17.5.2.1.4255 moduleSdtTableStatus OBJECT-TYPE SYNTAX INTEGER { sdtTableOk(1), invalidSdtTableTemplate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sdt table template status" ::= { moduleStatusEntry 4255 } -- 1.3.6.1.4.1.3715.17.5.2.1.4256 moduleDescramblingRestart OBJECT-TYPE SYNTAX INTEGER { descramblingNominal(1), descramblingRestarting(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Descrambling restart status" ::= { moduleStatusEntry 4256 } -- 1.3.6.1.4.1.3715.17.5.2.1.4257 moduleCaModuleRestart OBJECT-TYPE SYNTAX INTEGER { caModuleNominal(1), caModuleRestarting(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "CA module restart status" ::= { moduleStatusEntry 4257 } -- 1.3.6.1.4.1.3715.17.5.2.1.4258 moduleCaMenuStatus OBJECT-TYPE SYNTAX INTEGER { caMenuNominal(1), caMenuOpen(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "CA menu access status" ::= { moduleStatusEntry 4258 } -- 1.3.6.1.4.1.3715.17.5.2.1.4259 moduleInvalidCamRouting OBJECT-TYPE SYNTAX INTEGER { camRoutingNominal(1), camRoutingInvalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "CAM routing status" ::= { moduleStatusEntry 4259 } -- 1.3.6.1.4.1.3715.17.5.2.1.4260 moduleNitSidConflict OBJECT-TYPE SYNTAX INTEGER { nitSidNominal(1), nitSidConflict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Nit / Sid conflict status" ::= { moduleStatusEntry 4260 } -- 1.3.6.1.4.1.3715.17.5.2.1.4262 moduleLicenseMissingFEC OBJECT-TYPE SYNTAX INTEGER { licenseOk(1), licenseMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "FEC license status" ::= { moduleStatusEntry 4262 } -- 1.3.6.1.4.1.3715.17.5.2.1.4263 moduleFecCorrectionStatus OBJECT-TYPE SYNTAX INTEGER { correctionNominal(1), correctionOverload(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fec packet correction status. Correction overload (2) is result of too many simultaneous missing packets." ::= { moduleStatusEntry 4263 } -- 1.3.6.1.4.1.3715.17.5.2.1.4264 moduleFecPacketDropStatus OBJECT-TYPE SYNTAX INTEGER { packetsNominal(1), packetsDropped(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "FEC packet discarding status. Packet discarding (2) is resulted by too high bitrate." ::= { moduleStatusEntry 4264 } -- 1.3.6.1.4.1.3715.17.5.2.1.4265 moduleFecMediaPktsStatus OBJECT-TYPE SYNTAX INTEGER { packetsNominal(1), packetsDiscarded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fec media packet discarding status. Packet discarding (2) is resulted by too high bitrate." ::= { moduleStatusEntry 4265 } -- 1.3.6.1.4.1.3715.17.5.2.1.4269 moduleSfpLinkStatus OBJECT-TYPE SYNTAX INTEGER { sfpLinkNominal(1), sfpLinkDown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "SFP link status" ::= { moduleStatusEntry 4269 } -- 1.3.6.1.4.1.3715.17.5.2.1.4272 moduleBackupSyncModeOff OBJECT-TYPE SYNTAX INTEGER { modeNominal(1), modeOff(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync mode off status flag" ::= { moduleStatusEntry 4272 } -- 1.3.6.1.4.1.3715.17.5.2.1.4273 moduleBackupSyncModeManual OBJECT-TYPE SYNTAX INTEGER { modeNominal(1), modeManual(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync mode manual status flag" ::= { moduleStatusEntry 4273 } -- 1.3.6.1.4.1.3715.17.5.2.1.4274 moduleBackupSyncModeAuto OBJECT-TYPE SYNTAX INTEGER { modeNominal(1), modeAuto(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync mode automatic status flag" ::= { moduleStatusEntry 4274 } -- 1.3.6.1.4.1.3715.17.5.2.1.4275 moduleBackupSyncConfStatus OBJECT-TYPE SYNTAX INTEGER { configurationNominal(1), configurationChanged(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync configuration change status" ::= { moduleStatusEntry 4275 } -- 1.3.6.1.4.1.3715.17.5.2.1.4276 moduleBackupSyncStatus OBJECT-TYPE SYNTAX INTEGER { syncNominal(1), synchronizing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup configuration synchronization status" ::= { moduleStatusEntry 4276 } -- 1.3.6.1.4.1.3715.17.5.2.1.4278 moduleBackupSyncSwCompatibility OBJECT-TYPE SYNTAX INTEGER { swCompatible(1), swIncompatible(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Software version compatibility for backup sync" ::= { moduleStatusEntry 4278 } -- 1.3.6.1.4.1.3715.17.5.2.1.4279 moduleBackupSyncHwCompatibility OBJECT-TYPE SYNTAX INTEGER { hwCompatible(1), hwIncompatible(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware version compatibility for backup sync" ::= { moduleStatusEntry 4279 } -- 1.3.6.1.4.1.3715.17.5.2.1.4280 moduleBackupSyncConfFaultStatus OBJECT-TYPE SYNTAX INTEGER { configurationNominal(1), configurationFault(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync configuration fault status" ::= { moduleStatusEntry 4280 } -- 1.3.6.1.4.1.3715.17.5.2.1.4281 moduleBackupSyncConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connectionNominal(1), connectionLost(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync connection status" ::= { moduleStatusEntry 4281 } -- 1.3.6.1.4.1.3715.17.5.2.1.4283 moduleBackupSyncFromBackupStatus OBJECT-TYPE SYNTAX INTEGER { syncNominal(1), syncNotPossible(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for backup autosync from backup to main" ::= { moduleStatusEntry 4283 } -- 1.3.6.1.4.1.3715.17.5.2.1.4284 moduleBackupSyncRebootStatus OBJECT-TYPE SYNTAX INTEGER { pairDevNominal(1), pairDevRebooting(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for rebooting pair device to new configuration" ::= { moduleStatusEntry 4284 } -- 1.3.6.1.4.1.3715.17.5.2.1.4285 moduleBackupSyncLicenseCompatStatus OBJECT-TYPE SYNTAX INTEGER { licensesCompatible(1), licensesIncompatible(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "License compatibility status flag for backup sync" ::= { moduleStatusEntry 4285 } -- 1.3.6.1.4.1.3715.17.5.2.1.4286 moduleBackupSyncLicenseCompareStatus OBJECT-TYPE SYNTAX INTEGER { licenseNominal(1), licenseComparing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Backup sync license comparing status" ::= { moduleStatusEntry 4286 } -- 1.3.6.1.4.1.3715.17.5.2.1.4288 moduleDeviceFirstBootStatus OBJECT-TYPE SYNTAX INTEGER { firstBootNominal(1), firstBootInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for device first boot operations" ::= { moduleStatusEntry 4288 } -- 1.3.6.1.4.1.3715.17.5.2.1.4289 modulePartitionConfigurationBackup OBJECT-TYPE SYNTAX INTEGER { configurationNominal(1), configurationBackupInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for partition configuration backup operation" ::= { moduleStatusEntry 4289 } -- 1.3.6.1.4.1.3715.17.5.2.1.4290 modulePartitionConfigurationRestore OBJECT-TYPE SYNTAX INTEGER { configurationNominal(1), configurationRestoreInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for partition configuration restore operation" ::= { moduleStatusEntry 4290 } -- 1.3.6.1.4.1.3715.17.5.2.1.4291 moduleSwRevertStatus OBJECT-TYPE SYNTAX INTEGER { swNominal(1), swRevertInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Software revertion status" ::= { moduleStatusEntry 4291 } -- 1.3.6.1.4.1.3715.17.5.2.1.4292 moduleMaxOutputPidsStatus OBJECT-TYPE SYNTAX INTEGER { pidsNominal(1), maxPidsUsed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for maximum number of Pid allocations" ::= { moduleStatusEntry 4292 } -- 1.3.6.1.4.1.3715.17.5.2.1.4293 moduleUserRebootStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleRebootedByUser(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for user initiated reboot" ::= { moduleStatusEntry 4293 } -- 1.3.6.1.4.1.3715.17.5.2.1.4294 moduleRemovalStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleRemoved(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for module removal" ::= { moduleStatusEntry 4294 } -- 1.3.6.1.4.1.3715.17.5.2.1.4295 moduleInsertionStatus OBJECT-TYPE SYNTAX INTEGER { moduleNominal(1), moduleInserted(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for module insertion" ::= { moduleStatusEntry 4295 } -- 1.3.6.1.4.1.3715.17.5.2.1.4296 moduleSptsInputConfStatus OBJECT-TYPE SYNTAX INTEGER { sptsInputNominal(1), inputNotSpts(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for input spts misconfiguration" ::= { moduleStatusEntry 4296 } -- 1.3.6.1.4.1.3715.17.5.3 ifStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IfStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { statusFlags 3 } -- 1.3.6.1.4.1.3715.17.5.3.1 ifStatusEntry OBJECT-TYPE SYNTAX IfStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { moduleId, ifDirection, ifId } ::= { ifStatusTable 1 } IfStatusEntry ::= SEQUENCE { ifId INTEGER, ifDirection INTEGER, ifSignalStatus INTEGER, ifAsiLinkStatus INTEGER, ifLinkStatus INTEGER } -- 1.3.6.1.4.1.3715.17.5.3.1.1 ifId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface identifier" ::= { ifStatusEntry 1 } -- 1.3.6.1.4.1.3715.17.5.3.1.2 ifDirection OBJECT-TYPE SYNTAX INTEGER { input(1), output(2), both(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface data direction" ::= { ifStatusEntry 2 } -- 1.3.6.1.4.1.3715.17.5.3.1.4097 ifSignalStatus OBJECT-TYPE SYNTAX INTEGER { signalOk(1), signalMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Interface signal status" ::= { ifStatusEntry 4097 } -- 1.3.6.1.4.1.3715.17.5.3.1.4102 ifAsiLinkStatus OBJECT-TYPE SYNTAX INTEGER { linkOk(1), linkDown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "ASI link status" ::= { ifStatusEntry 4102 } -- 1.3.6.1.4.1.3715.17.5.3.1.4226 ifLinkStatus OBJECT-TYPE SYNTAX INTEGER { linkOk(1), linkDown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Interface link status" ::= { ifStatusEntry 4226 } -- 1.3.6.1.4.1.3715.17.5.4 tsStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF TsStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { statusFlags 4 } -- 1.3.6.1.4.1.3715.17.5.4.1 tsStatusEntry OBJECT-TYPE SYNTAX TsStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { moduleId, ifDirection, ifId } ::= { tsStatusTable 1 } TsStatusEntry ::= SEQUENCE { tsPidRemappingStatus INTEGER, tsManualTableInsertStatus INTEGER, tsPassthruDupStatus INTEGER, tsSyncStatus INTEGER, tsRxStatus INTEGER, tsInputBufferStatus INTEGER, tsNetworkStatus INTEGER, tsPsisiCapaStatus INTEGER, tsMultiplexDiscardStatus INTEGER, tsMultiplexDelayStatus INTEGER, tsCbrOversubscriptionStatus INTEGER, tsCbrDiscardStatus INTEGER, tsIpInputCapaStatus INTEGER, tsEitReinsertCapaStatus INTEGER, tsSectionCapaStatus INTEGER, tsRtpInputStatus INTEGER, tsRtpSeqStatus INTEGER, tsTdtTotGenStatus INTEGER, tsSttGenStatus INTEGER, tsFecPacketCorrectionStatus INTEGER, tsFecInputAnomalyStatus INTEGER, tsFecCorrectionCapacityStatus INTEGER, tsIpMirrorOutputPacketLossStatus INTEGER } -- 1.3.6.1.4.1.3715.17.5.4.1.5 tsPidRemappingStatus OBJECT-TYPE SYNTAX INTEGER { pidNominal(1), pidRemapped(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS PID remapping status" ::= { tsStatusEntry 5 } -- 1.3.6.1.4.1.3715.17.5.4.1.8 tsManualTableInsertStatus OBJECT-TYPE SYNTAX INTEGER { insertOk(1), insertFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS manual table insertion status" ::= { tsStatusEntry 8 } -- 1.3.6.1.4.1.3715.17.5.4.1.11 tsPassthruDupStatus OBJECT-TYPE SYNTAX INTEGER { servicesNominal(1), servicesBlocked(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS output service passthrough duplication status" ::= { tsStatusEntry 11 } -- 1.3.6.1.4.1.3715.17.5.4.1.4098 tsSyncStatus OBJECT-TYPE SYNTAX INTEGER { syncOk(1), noSync(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS sync status" ::= { tsStatusEntry 4098 } -- 1.3.6.1.4.1.3715.17.5.4.1.4099 tsRxStatus OBJECT-TYPE SYNTAX INTEGER { rxNominal(1), rxErrors(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS Rx error status" ::= { tsStatusEntry 4099 } -- 1.3.6.1.4.1.3715.17.5.4.1.4100 tsInputBufferStatus OBJECT-TYPE SYNTAX INTEGER { bufferNominal(1), bufferOverflow(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS input buffer status" ::= { tsStatusEntry 4100 } -- 1.3.6.1.4.1.3715.17.5.4.1.4103 tsNetworkStatus OBJECT-TYPE SYNTAX INTEGER { netOk(1), netForbidden(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS network ID status" ::= { tsStatusEntry 4103 } -- 1.3.6.1.4.1.3715.17.5.4.1.4109 tsPsisiCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS PSI/SI insertion capacity status" ::= { tsStatusEntry 4109 } -- 1.3.6.1.4.1.3715.17.5.4.1.4110 tsMultiplexDiscardStatus OBJECT-TYPE SYNTAX INTEGER { muxNominal(1), muxPacketsDiscarded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS multiplex packet discard status" ::= { tsStatusEntry 4110 } -- 1.3.6.1.4.1.3715.17.5.4.1.4228 tsMultiplexDelayStatus OBJECT-TYPE SYNTAX INTEGER { muxNominal(1), muxPacketsDelayed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS multiplex packet delay status" ::= { tsStatusEntry 4228 } -- 1.3.6.1.4.1.3715.17.5.4.1.4229 tsCbrOversubscriptionStatus OBJECT-TYPE SYNTAX INTEGER { cbrNominal(1), cbrOversubscription(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS CBR oversubscription status" ::= { tsStatusEntry 4229 } -- 1.3.6.1.4.1.3715.17.5.4.1.4236 tsCbrDiscardStatus OBJECT-TYPE SYNTAX INTEGER { cbrNominal(1), cbrPacketsDiscarded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS CBR packet discard due to oversubscription status" ::= { tsStatusEntry 4236 } -- 1.3.6.1.4.1.3715.17.5.4.1.4238 tsIpInputCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS IP input capacity status" ::= { tsStatusEntry 4238 } -- 1.3.6.1.4.1.3715.17.5.4.1.4239 tsEitReinsertCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS EIT reinsert capacity status" ::= { tsStatusEntry 4239 } -- 1.3.6.1.4.1.3715.17.5.4.1.4240 tsSectionCapaStatus OBJECT-TYPE SYNTAX INTEGER { capacityNominal(1), capacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS section processing capacity status" ::= { tsStatusEntry 4240 } -- 1.3.6.1.4.1.3715.17.5.4.1.4241 tsRtpInputStatus OBJECT-TYPE SYNTAX INTEGER { inputOk(1), inputPacketsDropped(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS RTP input packet droip status" ::= { tsStatusEntry 4241 } -- 1.3.6.1.4.1.3715.17.5.4.1.4242 tsRtpSeqStatus OBJECT-TYPE SYNTAX INTEGER { seqOk(1), seqAnomalies(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS RTP input packet sequence anomaly status" ::= { tsStatusEntry 4242 } -- 1.3.6.1.4.1.3715.17.5.4.1.4246 tsTdtTotGenStatus OBJECT-TYPE SYNTAX INTEGER { tdtTotOk(1), tdtTotNotGenerated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS output TDT/TOT table generation status" ::= { tsStatusEntry 4246 } -- 1.3.6.1.4.1.3715.17.5.4.1.4261 tsSttGenStatus OBJECT-TYPE SYNTAX INTEGER { sttOk(1), sttNotGenerated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "TS output STT table generation status" ::= { tsStatusEntry 4261 } -- 1.3.6.1.4.1.3715.17.5.4.1.4266 tsFecPacketCorrectionStatus OBJECT-TYPE SYNTAX INTEGER { packetsNominal(1), fecCorrectedPackets(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for FEC correcting packets" ::= { tsStatusEntry 4266 } -- 1.3.6.1.4.1.3715.17.5.4.1.4267 tsFecInputAnomalyStatus OBJECT-TYPE SYNTAX INTEGER { fecInputNominal(1), fecInputAnomalies(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for FEC input anomaly detection" ::= { tsStatusEntry 4267 } -- 1.3.6.1.4.1.3715.17.5.4.1.4268 tsFecCorrectionCapacityStatus OBJECT-TYPE SYNTAX INTEGER { correctionCapacityNominal(1), correctionCapacityExceeded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fec input packets correction capacity status" ::= { tsStatusEntry 4268 } -- 1.3.6.1.4.1.3715.17.5.4.1.4297 tsIpMirrorOutputPacketLossStatus OBJECT-TYPE SYNTAX INTEGER { ipOutputNominal(1), ipOutputPacketsDiscarded(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status flag for IP mirror output packet discarding" ::= { tsStatusEntry 4297 } -- 1.3.6.1.4.1.3715.17.5.5 serviceStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ServiceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { statusFlags 5 } -- 1.3.6.1.4.1.3715.17.5.5.1 serviceStatusEntry OBJECT-TYPE SYNTAX ServiceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { moduleId, ifDirection, ifId, serviceId } ::= { serviceStatusTable 1 } ServiceStatusEntry ::= SEQUENCE { serviceId INTEGER, serviceStatus INTEGER } -- 1.3.6.1.4.1.3715.17.5.5.1.1 serviceId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Service identifier" ::= { serviceStatusEntry 1 } -- 1.3.6.1.4.1.3715.17.5.5.1.3 serviceStatus OBJECT-TYPE SYNTAX INTEGER { servicePresent(1), serviceMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Service status" ::= { serviceStatusEntry 3 } -- 1.3.6.1.4.1.3715.17.5.6 pidStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PidStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { statusFlags 6 } -- 1.3.6.1.4.1.3715.17.5.6.1 pidStatusEntry OBJECT-TYPE SYNTAX PidStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { moduleId, ifDirection, ifId, pId } ::= { pidStatusTable 1 } PidStatusEntry ::= SEQUENCE { pId INTEGER, pidStatus INTEGER } -- 1.3.6.1.4.1.3715.17.5.6.1.1 pId OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Program Identifier" ::= { pidStatusEntry 1 } -- 1.3.6.1.4.1.3715.17.5.6.1.2 pidStatus OBJECT-TYPE SYNTAX INTEGER { pidPresent(1), pidMissing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "PID status" ::= { pidStatusEntry 2 } END -- -- TELESTE-LUMINATO-MIB.mib --