-- ***************************************************************** -- TN-LOOP-PROTECT-MIB.my : TN Loop Protection MIB -- -- Copyright (c) 2012 by Transition Networks, Inc. -- All rights reserved. -- -- ***************************************************************** TN-LOOP-PROTECT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF entPhysicalIndex FROM ENTITY-MIB ifIndex FROM IF-MIB TruthValue, TimeStamp, DateAndTime, DisplayString FROM SNMPv2-TC tnProducts FROM TRANSITION-SMI; tnLoopProtectMIB MODULE-IDENTITY LAST-UPDATED "201207251030Z" ORGANIZATION "Transition Networks, Inc." CONTACT-INFO "Transition Networks Technical Support 10900 Red Circle Drive Minnetonka, MN 55343 USA Tel: +1-800-526-9267 E-mail: techsupport@transition.com" DESCRIPTION "The mib module for managing all transition products with Loop protection" REVISION "201207251030Z" DESCRIPTION "Initial version of this MIB module." ::= { tnProducts 22 } tnLoopProtectNotifications OBJECT IDENTIFIER ::= { tnLoopProtectMIB 0 } tnLoopProtectObjects OBJECT IDENTIFIER ::= { tnLoopProtectMIB 1 } tnLoopProtectLoopDetectedNotification NOTIFICATION-TYPE OBJECTS { ifIndex, tnLoopProtectPortLoopCount, tnLoopProtectPortAction} STATUS current DESCRIPTION "A tnLoopProtectLoopDetectedNotification signifies that a loop has been detected by the loop protection protocol. Additional infomation contains port number ,count of loop detected on the port and the action will be execute" ::= { tnLoopProtectNotifications 1 } tnLoopProtectMgmt OBJECT IDENTIFIER ::= { tnLoopProtectObjects 1 } tnLoopProtectBaseTable OBJECT-TYPE SYNTAX SEQUENCE OF TnLoopProtectBaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for configuring global loop protect variables" ::= { tnLoopProtectMgmt 1 } tnLoopProtectBaseEntry OBJECT-TYPE SYNTAX TnLoopProtectBaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains configuration elements of tnLoopProtectBaseTable" INDEX { entPhysicalIndex } ::= { tnLoopProtectBaseTable 1 } TnLoopProtectBaseEntry ::= SEQUENCE { tnLoopProtectEnable TruthValue, tnLoopProtectTxTime INTEGER, tnLoopProtectShutdownTime INTEGER } tnLoopProtectEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the loop protect is enable on this device." ::= { tnLoopProtectBaseEntry 1 } tnLoopProtectTxTime OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval in seconds between each loop protection PDU sent on each port. valid values are 1 to 10 seconds,the default value is 5 seconds." ::= { tnLoopProtectBaseEntry 2 } tnLoopProtectShutdownTime OBJECT-TYPE SYNTAX INTEGER (0..604800) MAX-ACCESS read-write STATUS current DESCRIPTION "The period (in seconds) for which a port will be kept disabled in the event of a loop is detected (and the port action shuts down the port). Valid values are 0 to 604800 seconds (7 days). A value of zero will keep a port disabled (until next device restart)." ::= { tnLoopProtectBaseEntry 3 } tnLoopProtectPortTable OBJECT-TYPE SYNTAX SEQUENCE OF TnLoopProtectPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for configuring loop protect options for each port" ::= { tnLoopProtectMgmt 2 } tnLoopProtectPortEntry OBJECT-TYPE SYNTAX TnLoopProtectPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains configuration element of tnLoopProtectBaseTable" INDEX { ifIndex } ::= { tnLoopProtectPortTable 1 } TnLoopProtectPortEntry ::= SEQUENCE { tnLoopProtectPortEnable TruthValue, tnLoopProtectPortAction INTEGER, tnLoopProtectPortTxModeEnable TruthValue, tnLoopProtectPortLoopCount Counter32, tnLoopProtectPortStatus INTEGER, tnLoopProtectPortLoopDetected TruthValue, tnLoopProtectPortLastLoopTime DateAndTime } tnLoopProtectPortEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether loop protection is enabled on this switch port." ::= {tnLoopProtectPortEntry 1} tnLoopProtectPortAction OBJECT-TYPE SYNTAX INTEGER {shutdown(1),shutdownAndlog(2),log(3),trap(4),shutdownAndtrap(5),logAndtrap(6),all(7)} MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the action performed when a loop is detected on a port. Valid values are Shutdown Port(1), Shutdown Port and Log(2) or Log Only(3)." ::= { tnLoopProtectPortEntry 2 } tnLoopProtectPortTxModeEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port is actively generating loop protection PDU's, or whether it is just passively looking for looped PDU's." ::= { tnLoopProtectPortEntry 3 } tnLoopProtectPortLoopCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loops detected on this port." ::= { tnLoopProtectPortEntry 4 } tnLoopProtectPortStatus OBJECT-TYPE SYNTAX INTEGER{up(1),down(2),disable(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port. up(1): the status of the port is up. down(2):the status of the port is down. disable(3):loop is detected in this port and shutdown is triggered at the same time" ::= { tnLoopProtectPortEntry 5 } tnLoopProtectPortLoopDetected OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Whether a loop is currently detected on the port." ::= { tnLoopProtectPortEntry 6 } tnLoopProtectPortLastLoopTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last loop event detected." ::= { tnLoopProtectPortEntry 7 } END