-- *********************************************************************************************** -- TN-PTP-MIB.smi: Transition Networks Enterprise MIB for TN device SyncE feature -- -- Copyright (c) 2013 by Transition Networks, Inc. -- All rights reserved. -- -- *********************************************************************************************** -- TN-PTP-MIB DEFINITIONS ::= BEGIN IMPORTS TruthValue, RowStatus FROM SNMPv2-TC MODULE-IDENTITY, OBJECT-IDENTITY, InetAddressType, InetAddress FROM INET-ADDRESS-MIB entPhysicalIndex FROM ENTITY-MIB tnProducts FROM TRANSITION-SMI; tnPtpMIB MODULE-IDENTITY LAST-UPDATED "201311110000Z" ORGANIZATION "Transition Networks, Inc." CONTACT-INFO " Transition Networks Technical Support 10900 Red Circle Drive Minnetonka, MN 55343 USA Tel: +1-800-526-9267 E-mail: techsupport@transition.com" DESCRIPTION "The mib provides functionalities for managing PTP." REVISION "201311110000Z" DESCRIPTION "Initial Revision of this module" ::= { tnProducts 123 } tnPtp OBJECT IDENTIFIER ::= { tnPtpMIB 1 } -- -- PTP Clock Modes -- tnPtpClkModesTable OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpClkModesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of SyncE External I/O" ::= { tnPtp 1 } tnPtpClkModesEntry OBJECT-TYPE SYNTAX TnPtpClkModesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpClkModesTable" INDEX { entPhysicalIndex } ::= { tnPtpClkModesTable 1 } TnPtpClkModesEntry ::= SEQUENCE { tnPtpInState INTEGER, tnPtpOutState INTEGER, tnPtpInFreq INTEGER, tnPtpOutFreq INTEGER, tnPtpImpedance INTEGER, tnPtpActualInFreq INTEGER, tnPtpActualOutFreq INTEGER } tnPtpInState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IEEE 1588 Input State." ::= { tnPtpClkModesEntry 1 } tnPtpOutState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IEEE 1588 Output State." ::= { tnPtpClkModesEntry 2 } tnPtpInFreq OBJECT-TYPE SYNTAX INTEGER { onePps(0), f8kHz(1), f64kHz(2), f1544kHz(3), f2048kHz(4), f10000kHz(5), f19440kHz(6), f25Mhz(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock frequency 1 PPS or 8k-25Mhz table of values." ::= { tnPtpClkModesEntry 3 } tnPtpOutFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The following values are possible: Editable value with the possible range of values are 1 - 25000000 (1 - 25MHz)." ::= { tnPtpClkModesEntry 4 } tnPtpImpedance OBJECT-TYPE SYNTAX INTEGER { imp50(1), imp75(2), hi-Z(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select the impedance termination of the input clock. The following values are possible: 1. 50 : 50 ohm impedance. 2. 75 : 75 ohm impedance. 3. Hi-Z : no impedance termination driven, tri-stated or floating." ::= { tnPtpClkModesEntry 5 } tnPtpActualInFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The actual input frequency in Hz." ::= { tnPtpClkModesEntry 6 } tnPtpActualOutFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0" ::= { tnPtpClkModesEntry 7 } -- -- PTP Add New Clk Configuration -- tnPtpCreateClkConfTable OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpCreateClkConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PTP ClkInstance" ::= { tnPtp 2 } tnPtpCreateClkConfEntry OBJECT-TYPE SYNTAX TnPtpCreateClkConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpCreateClkConfTable" INDEX { tnPtpCreateClkConfIndex } ::= { tnPtpCreateClkConfTable 1 } TnPtpCreateClkConfEntry ::= SEQUENCE { tnPtpCreateClkConfIndex INTEGER, tnPtpDeviceType INTEGER, tnPtpTwoStepFlag TruthValue, tnPtpClockId OCTET STRING, tnPtpOneWay TruthValue, tnPtpProtocol INTEGER, tnPtpVLANTag TruthValue, tnPtpVID INTEGER, tnPtpPCP INTEGER, tnPtpClkConfRowStatus RowStatus } tnPtpCreateClkConfIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of ptp clocks." ::= { tnPtpCreateClkConfEntry 1 } tnPtpDeviceType OBJECT-TYPE SYNTAX INTEGER { inactive(0), ordBound(1), p2pTransp(2), e2eTransp(3), masterOnly(4), slaveOnly(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the Type of the Clock Instance. There are five Device Types. 1. Ord-Bound - clock's Device Type is Ordinary-Boundary Clock. 2. P2p Transp - clock's Device Type is Peer to Peer Transparent Clock. 3. E2e Transp - clock's Device Type is End to End Transparent Clock. 4. Master Only - clock's Device Type is Master Only. 5. Slave Only - clock's Device Type is Slave Only." ::= { tnPtpCreateClkConfEntry 2 } tnPtpTwoStepFlag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Static member: defined by the system, true if two-step Sync events and Pdelay_Resp events are used." ::= { tnPtpCreateClkConfEntry 3 } tnPtpClockId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-create STATUS current DESCRIPTION "A unique clock identifier." ::= { tnPtpCreateClkConfEntry 4 } tnPtpOneWay OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If true, one-way measurements are used. This parameter applies only to a slave. In one-way mode no delay measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master always responds to delay requests.." ::= { tnPtpCreateClkConfEntry 5 } tnPtpProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(0), ipv4multi(1), ipv4uni(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Transport protocol used by the PTP protocol engine ethernet PTP over Ethernet multicast ip4multi PTP over IPv4 multicast ip4uni PTP over IPv4 unicast Note : IPv4 unicast protocol only works in Master only and Slave only clocks See parameter Device Type In a unicast Slave only clock you also need configure which master clocks to request Announce and Sync messages from. See: Unicast Slave Configuration." ::= { tnPtpCreateClkConfEntry 6 } tnPtpVLANTag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Enables the VLAN tagging for the PTP frames. Note: Packets are only tagged if the port is configured for vlan tagging. i.e: Port Type != Unaware and PortVLAN mode == None, and the port is member of the VLAN." ::= { tnPtpCreateClkConfEntry 7 } tnPtpVID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN Identifier used for tagging the PTP frames." ::= { tnPtpCreateClkConfEntry 8 } tnPtpPCP OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Priority Code Point value used for PTP frames." ::= { tnPtpCreateClkConfEntry 9 } tnPtpClkConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the row. The writable columns in a row cannot be changed if the row is active. All columns must have a valid value before a row can be activated." ::= { tnPtpCreateClkConfEntry 10 } -- -- PTP Clk Configuration 0 -- tnPtpClkConf0Table OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpClkConf0Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PTP ClkInstance" ::= { tnPtp 3 } tnPtpClkConf0Entry OBJECT-TYPE SYNTAX TnPtpClkConf0Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpClkConf0Table" INDEX { tnPtpClkConf0Index } ::= { tnPtpClkConf0Table 1 } TnPtpClkConf0Entry ::= SEQUENCE { tnPtpClkConf0Index INTEGER, tnPtpDefaultDom INTEGER, tnPtpDefaultClockQuality OCTET STRING, tnPtpDefaultPri1 INTEGER, tnPtpDefaultPri2 INTEGER, tnPtpTime OCTET STRING, tnPtpAdjustMethod INTEGER, tnPtpSynce INTEGER, } tnPtpClkConf0Index OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]." ::= { tnPtpClkConf0Entry 1 } tnPtpDefaultDom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Clock domain [0..127]." ::= { tnPtpClkConf0Entry 2 } tnPtpDefaultClockQuality OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "The clock quality is determined by the system, and holds 3 parts: Clock Class, Clock Accuracy and OffsetScaledLog Variance as defined in IEEE1588. The Clock Accuracy values are defined in IEEE1588 table 6 (Currently the clock Accuracy is set to 'Unknown' as default)." ::= { tnPtpClkConf0Entry 3 } tnPtpDefaultPri1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Clock priority 1 [0..255] used by the BMC master select algorithm." ::= { tnPtpClkConf0Entry 4 } tnPtpDefaultPri2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Clock priority 2 [0..255] used by the BMC master select algorithm." ::= { tnPtpClkConf0Entry 5 } tnPtpTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the actual PTP time with nanosecond resolution." ::= { tnPtpClkConf0Entry 6 } tnPtpAdjustMethod OBJECT-TYPE SYNTAX INTEGER { internal(1), vcxo(2), software(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the actual clock adjustment method. The method depends on the available hardware." ::= { tnPtpClkConf0Entry 7 } tnPtpSynce OBJECT-TYPE SYNTAX INTEGER { doNothing(1), sync(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate to synchronize the System Clock to PTP Time." ::= { tnPtpClkConf0Entry 8 } -- -- PTP Clk Configuration 1 -- tnPtpClkConfTable OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpClkConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PTP ClkInstance" ::= { tnPtp 4 } tnPtpClkConfEntry OBJECT-TYPE SYNTAX TnPtpClkConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpClkConfTable" INDEX { tnPtpClkConfIndex } ::= { tnPtpClkConfTable 1 } TnPtpClkConfEntry ::= SEQUENCE { tnPtpClkConfIndex INTEGER, tnPtpStpRm INTEGER, tnPtpOffset OCTET STRING, tnPtpPathDelay OCTET STRING, tnPtpDelayFilter INTEGER, tnPtpFilterPeriod INTEGER, tnPtpFilterDist INTEGER, tnPtpParentPortId OCTET STRING, tnPtpParentPort INTEGER, tnPtpParentPStat TruthValue, tnPtpParentVar INTEGER, tnPtpParentChgRate INTEGER, tnPtpParentGMId OCTET STRING, tnPtpParentGMQual OCTET STRING, tnPtpParentPri1 INTEGER, tnPtpParentPri2 INTEGER } tnPtpClkConfIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]." ::= { tnPtpClkConfEntry 1 } tnPtpStpRm OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Steps Removed : It is the number of PTP clocks traversed from the grandmaster to the local slave clock." ::= { tnPtpClkConfEntry 2 } tnPtpOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time difference between the master clock and the local slave clock, measured in ns." ::= { tnPtpClkConfEntry 3 } tnPtpPathDelay OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "The mean propagation time for the link between the master and the local slave." ::= { tnPtpClkConfEntry 4 } tnPtpDelayFilter OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate. The value must be in the range of 1..6." ::= { tnPtpClkConfEntry 5 } tnPtpFilterPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default offset filter uses a minimum delay filter method i.e. The minimum measured offset during Period samples is used in the calculation. The value must be in the range of 1..1000." ::= { tnPtpClkConfEntry 6 } tnPtpFilterDist OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The distance between two calculations is Dist periods. Note: In configurations with Timestamp enabled PHYs, the period is automatically increased, if (period*dist < SyncPackets pr sec/4), i.e. max 4 adjustments are made pr sec. If Dist is 1 the offset is averaged over the Period, If Dist is >1 the offset is calculated using 'min' offset. The value must be in the range of 1..10" ::= { tnPtpClkConfEntry 7 } tnPtpParentPortId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Clock identity for the parent clock, if the local clock is not a slave, the value is the clocks own id." ::= { tnPtpClkConfEntry 8 } tnPtpParentPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Port Id for the parent master port." ::= { tnPtpClkConfEntry 9 } tnPtpParentPStat OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Parents Stats (always false)." ::= { tnPtpClkConfEntry 10 } tnPtpParentVar OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "It is observed parent offset scaled log variance." ::= { tnPtpClkConfEntry 11 } tnPtpParentChgRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset compared to the master. (unit = ns per s)." ::= { tnPtpClkConfEntry 12 } tnPtpParentGMId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Clock identity for the grand master clock, if the local clock is not a slave, the value is the clocks own id." ::= { tnPtpClkConfEntry 13 } tnPtpParentGMQual OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "The clock quality announced by the grand master." ::= { tnPtpClkConfEntry 14 } tnPtpParentPri1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Clock priority 1 announced by the grand master." ::= { tnPtpClkConfEntry 15 } tnPtpParentPri2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Clock priority 2 announced by the grand master." ::= { tnPtpClkConfEntry 16 } -- -- PTP Clk Configuration 2 -- tnPtpClkConf2Table OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpClkConf2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table 2 of PTP ClkInstance" ::= { tnPtp 5 } tnPtpClkConf2Entry OBJECT-TYPE SYNTAX TnPtpClkConf2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpClkConf2Table" INDEX { tnPtpClkConfIndex2 } ::= { tnPtpClkConf2Table 1 } TnPtpClkConf2Entry ::= SEQUENCE { tnPtpClkConfIndex2 INTEGER, tnPtpUtcOffset INTEGER, tnPtpValid TruthValue, tnPtpLeap59 TruthValue, tnPtpLeap61 TruthValue, tnPtpTimeTrac TruthValue, tnPtpFreqTrac TruthValue, tnPtpTimeScale TruthValue, tnPtpTimeSource INTEGER, tnPtpDisplay TruthValue, tnPtpPEnable TruthValue, tnPtpIEnable TruthValue, tnPtpDEnable TruthValue, tnPtpPConstant INTEGER, tnPtpIConstant INTEGER, tnPtpDConstant INTEGER, tnPtpServoDelayFilter INTEGER } tnPtpClkConfIndex2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]." ::= { tnPtpClkConf2Entry 1 } tnPtpUtcOffset OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Unicast Offset must be an integer value between 0 and 10000." ::= { tnPtpClkConf2Entry 2 } tnPtpValid OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Valid." ::= { tnPtpClkConf2Entry 3 } tnPtpLeap59 OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Leap 59." ::= { tnPtpClkConf2Entry 4 } tnPtpLeap61 OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Leap 61." ::= { tnPtpClkConf2Entry 5 } tnPtpTimeTrac OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Time Trac." ::= { tnPtpClkConf2Entry 6 } tnPtpFreqTrac OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Freq Trac." ::= { tnPtpClkConf2Entry 7 } tnPtpTimeScale OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Time Scale." ::= { tnPtpClkConf2Entry 8 } tnPtpTimeSource OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Time Source. Value of 0-255" ::= { tnPtpClkConf2Entry 9 } tnPtpDisplay OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If true then Offset From Master, MeanPathDelay and clockAdjustment are logged on the debug terminal." ::= { tnPtpClkConf2Entry 10 } tnPtpPEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If true the P part of the algorithm is included." ::= { tnPtpClkConf2Entry 11 } tnPtpIEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If true the I part of the algorithm is included." ::= { tnPtpClkConf2Entry 12 } tnPtpDEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If true the D part of the algorithm is included." ::= { tnPtpClkConf2Entry 13 } tnPtpPConstant OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e. clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant + Differential OffsetFromMaster)/ D constant [1..1000]." ::= { tnPtpClkConf2Entry 14 } tnPtpIConstant OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e. clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant + Differential OffsetFromMaster)/ D constant [1..10000]." ::= { tnPtpClkConf2Entry 15 } tnPtpDConstant OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e. clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant + Differential OffsetFromMaster)/ D constant [1..10000]." ::= { tnPtpClkConf2Entry 16 } tnPtpServoDelayFilter OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate. This is for the custom filter." ::= { tnPtpClkConf2Entry 17 } -- -- PTP Unicast Slave Config -- tnPtpUnicastSlaveTable OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpUnicastSlaveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PTP Unicast Slave" ::= { tnPtp 6 } tnPtpUnicastSlaveEntry OBJECT-TYPE SYNTAX TnPtpUnicastSlaveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpUnicastSlaveTable" INDEX { tnPtpUnicastInstIndex, tnPtpUnicastSlaveIndex } ::= { tnPtpUnicastSlaveTable 1 } TnPtpUnicastSlaveEntry ::= SEQUENCE { tnPtpUnicastInstIndex INTEGER, tnPtpUnicastSlaveIndex INTEGER, tnPtpUnicastDuration INTEGER, tnPtpIPAddress InetAddress, tnPtpGrant INTEGER, tnPtpCommState INTEGER } tnPtpUnicastInstIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]." ::= { tnPtpUnicastSlaveEntry 1 } tnPtpUnicastSlaveIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Instance of a particular Unicast Slave [0..4]." ::= { tnPtpUnicastSlaveEntry 2 } tnPtpUnicastDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number of seconds a master is requested to send Announce/Sync messages. The request is repeated from the slave each Duration/4 seconds. [10..1000]." ::= { tnPtpUnicastSlaveEntry 3 } tnPtpIPAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 Address of the Master clock." ::= { tnPtpUnicastSlaveEntry 4 } tnPtpGrant OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The granted repetition period for the sync message." ::= { tnPtpUnicastSlaveEntry 5 } tnPtpCommState OBJECT-TYPE SYNTAX INTEGER { idle(1), init(2), conn(3), sell(4), sync(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The state of the communication with the master, possible values are: IDLE : The entry is not in use. INIT : Announce is sent to the master (Waiting for a response). CONN : The master has responded. SELL : The assigned master is selected as current master. SYNC : The master is sending Sync messages." ::= { tnPtpUnicastSlaveEntry 6 } -- -- PTP Clock Port Data Set Configuration -- tnPtpPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF TnPtpPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PTP Clock Port Data Set Configuration" ::= { tnPtp 7 } tnPtpPortConfEntry OBJECT-TYPE SYNTAX TnPtpPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table,tnPtpPortConfTable" INDEX { tnPtpPortConfInstIndex, tnPtpPortConfIndex } ::= { tnPtpPortConfTable 1 } TnPtpPortConfEntry ::= SEQUENCE { tnPtpPortConfInstIndex INTEGER, tnPtpPortConfIndex INTEGER, tnPtpStat OCTET STRING, tnPtpMDR INTEGER, tnPtpMeanPath OCTET STRING, tnPtpAnv INTEGER, tnPtpATO INTEGER, tnPtpSyv INTEGER, tnPtpSyncIntErr TruthValue, tnPtpDim INTEGER, tnPtpMPR INTEGER, tnPtpDelayAsym INTEGER, tnPtpIngerssLat INTEGER, tnPtpEgressLat INTEGER, tnPtpVersion INTEGER, tnPtpPortConfRowStatus RowStatus } tnPtpPortConfInstIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]." ::= { tnPtpPortConfEntry 1 } tnPtpPortConfIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Static member port Identity : Port number [1..max port no]." ::= { tnPtpPortConfEntry 2 } tnPtpStat OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dynamic member portState: Current state of the port." ::= { tnPtpPortConfEntry 3 } tnPtpMDR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dynamic member log Min Delay Req Interval: The delay request interval announced by the master." ::= { tnPtpPortConfEntry 4 } tnPtpMeanPath OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "The path delay measured by the port in P2P mode. In E2E mode this value is 0." ::= { tnPtpPortConfEntry 5 } tnPtpAnv OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The interval for issuing announce messages in master state. [-3..4]" ::= { tnPtpPortConfEntry 6 } tnPtpATO OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The timeout for receiving announce messages on the port. [-1..10]" ::= { tnPtpPortConfEntry 7 } tnPtpSyv OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The interval for issuing sync messages in master. [-7..4]" ::= { tnPtpPortConfEntry 8 } tnPtpSyncIntErr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS not-accessible STATUS current DESCRIPTION "Synce Interval Error truth value" ::= { tnPtpPortConfEntry 9 } tnPtpDim OBJECT-TYPE SYNTAX INTEGER { e2e(1), p2p(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configurable member delayMechanism: The delay mechanism used for the port: e2e End to end delay measurement p2p Peer to peer delay measurement. Can be defined per port in an Ordinary/Boundary clock. In a transparent clock all ports use the same delay mechanism, determined by the clock type." ::= { tnPtpPortConfEntry 10 } tnPtpMPR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The interval for issuing Delay_Req messages for the port in E2e mode. This value is announced from the master to the slave in an announce message. The value is reflected in the MDR field in the Slave The interval for issuing Pdelay_Req messages for the port in P2P mode Note: The interpretation of this parameter has changed from release 2.40. In earlier versions the value was interpreted relative to the Sync interval, this was a violation of the standard, so now the value is interpreted as an interval. I.e. MPR = 0 =>1 Delay_Req pr sec, independent of the Sync rate. [-7..5]" ::= { tnPtpPortConfEntry 11 } tnPtpDelayAsym OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "If the transmission delay for a link in not symmetric, the asymmetry can be configured here, see IEEE 1588 Section 7.4.2 Communication path asymmetry. [-100000..100000]" ::= { tnPtpPortConfEntry 12 } tnPtpIngerssLat OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Ingress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]" ::= { tnPtpPortConfEntry 13 } tnPtpEgressLat OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Egress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]" ::= { tnPtpPortConfEntry 14 } tnPtpVersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "The current implementation only supports PTP version 2." ::= { tnPtpPortConfEntry 15 } tnPtpPortConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the row. The writable columns in a row cannot be changed if the row is active. All columns must have a valid value before a row can be activated. " ::= { tnPtpPortConfEntry 16 } END