UBNT-EdgeMAX-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64, IpAddress, TimeTicks FROM SNMPv2-SMI DisplayString, TruthValue, MacAddress FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF ubntEdgeMaxGroups, ubntMIB FROM UBNT-MIB; ubntEdgeMax MODULE-IDENTITY LAST-UPDATED "201801030000Z" ORGANIZATION "Ubiquiti Networks, Inc." CONTACT-INFO "support@ubnt.com" DESCRIPTION "The EdgeMax MIB module for Ubiquiti Networks, Inc. entities" REVISION "201801030000Z" DESCRIPTION "ubntEdgeMax revision" ::= { ubntMIB 5 } -- -------------------------------------------------------------------------------- -- product identification -- -------------------------------------------------------------------------------- ubntProductIdent OBJECT IDENTIFIER ::= { ubntEdgeMax 1 } ubntModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Product model." ::= { ubntProductIdent 1 } ubntSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number." ::= { ubntProductIdent 2 } ubntVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version." ::= { ubntProductIdent 3 } -- -------------------------------------------------------------------------------- -- power outputs -- -------------------------------------------------------------------------------- ubntPowerOuts OBJECT IDENTIFIER ::= { ubntEdgeMax 2 } ubntPowerOutsCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of power outputs present on this system." ::= { ubntPowerOuts 1 } ubntPowerOutTable OBJECT-TYPE SYNTAX SEQUENCE OF UbntPowerOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of power out entries. The number of entries is given by the value of ubntPowerOutsCount." ::= { ubntPowerOuts 2 } ubntPowerOutEntry OBJECT-TYPE SYNTAX UbntPowerOutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ubntPowerOutTable." INDEX { ubntPowerOutIndex } ::= { ubntPowerOutTable 1 } UbntPowerOutTable ::= SEQUENCE { ubntPowerOutIndex Integer32, ubntPowerOutVoltage Integer32, ubntPowerOutCurrent Integer32, ubntPowerOutPower Integer32 } ubntPowerOutIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each power output." ::= { ubntPowerOutEntry 1 } ubntPowerOutVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Output voltage in mV." ::= { ubntPowerOutEntry 2 } ubntPowerOutCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Output current in mA." ::= { ubntPowerOutEntry 3 } ubntPowerOutPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Output power in mW." ::= { ubntPowerOutEntry 4 } -- -------------------------------------------------------------------------------- -- power supplies -- -------------------------------------------------------------------------------- ubntPowerSupplies OBJECT IDENTIFIER ::= { ubntEdgeMax 3 } ubntPsuBaysNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PSU bays available on this system." ::= { ubntPowerSupplies 1 } ubntPsuTable OBJECT-TYPE SYNTAX SEQUENCE OF UbntPsuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber." ::= { ubntPowerSupplies 2 } ubntPsuEntry OBJECT-TYPE SYNTAX UbntPsuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ubntPsuTable." INDEX { ubntPsuIndex } ::= { ubntPsuTable 1 } UbntPsuEntry ::= SEQUENCE { ubntPsuIndex Integer32, ubntPsuType INTEGER, ubntPsuStatus INTEGER, ubntPsuOperStatus INTEGER, ubntPsuVoltage Integer32, ubntPsuTemperature Integer32, ubntPsuCharging INTEGER, ubntPsuBatteryQuantity Integer32, ubntPsuBatteryChargeLevel INTEGER, ubntPsuBatteryTimeRemaining TimeTicks, ubntPsuBatteryReplaceIndicator INTEGER, ubntPsuBatteryLastReplaceDate DisplayString } ubntPsuIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each PSU." ::= { ubntPsuEntry 1 } ubntPsuType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ac(1), dc(2), poe(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "PSU Type." ::= { ubntPsuEntry 2 } ubntPsuStatus OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2), standby(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "PSU Status." ::= { ubntPsuEntry 3 } ubntPsuOperStatus OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PSU operational status." ::= { ubntPsuEntry 4 } ubntPsuVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PSU voltage in mV." ::= { ubntPsuEntry 5 } ubntPsuTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PSU temperature in thousands of degrees Celsius." ::= { ubntPsuEntry 6 } ubntPsuCharging OBJECT-TYPE SYNTAX INTEGER { unknown(0), on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shows PSU charging state if it is supported." ::= { ubntPsuEntry 7 } ubntPsuBatteryQuantity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of batteries connected to PSU." ::= { ubntPsuEntry 8 } ubntPsuBatteryChargeLevel OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Current battery charge level as a percent (0-100%)." ::= { ubntPsuEntry 9 } ubntPsuBatteryTimeRemaining OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The battery run time remaining before battery exhaustion." ::= { ubntPsuEntry 10 } ubntPsuBatteryReplaceIndicator OBJECT-TYPE SYNTAX INTEGER { unknown(0), noBatteryNeedsReplacing(1), batteryNeedsReplacing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the batteries need replacing." ::= { ubntPsuEntry 11 } ubntPsuBatteryLastReplaceDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery installation date (mm/dd/yyyy)." ::= { ubntPsuEntry 12 } -- -------------------------------------------------------------------------------- -- thermometers -- -------------------------------------------------------------------------------- ubntThermometers OBJECT IDENTIFIER ::= { ubntEdgeMax 4 } ubntThermometersCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of installed thermometers on this system." ::= { ubntThermometers 1 } ubntThermsTable OBJECT-TYPE SYNTAX SEQUENCE OF UbntThermsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of thermometers entries. The number of entries is given by the value of ubntThermometersCount." ::= { ubntThermometers 2 } ubntThermsEntry OBJECT-TYPE SYNTAX UbntThermsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ubntThermsTable." INDEX { ubntThermIndex } ::= { ubntThermsTable 1 } UbntThermsEntry ::= SEQUENCE { ubntThermIndex Integer32, ubntThermType Integer32, ubntThermTemperature Integer32 } ubntThermIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for thermometer." ::= { ubntThermsEntry 1 } ubntThermType OBJECT-TYPE SYNTAX INTEGER { other(0), board(1), cpu(2), power(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of thermometer." ::= { ubntThermsEntry 2 } ubntThermTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature in thousands of degrees Celsius." ::= { ubntThermsEntry 3 } -- -------------------------------------------------------------------------------- -- fans -- -------------------------------------------------------------------------------- ubntFans OBJECT IDENTIFIER ::= { ubntEdgeMax 5 } ubntFansCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of installed fans on this system." ::= { ubntFans 1 } ubntFansTable OBJECT-TYPE SYNTAX SEQUENCE OF UbntFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of fan entries. The number of entries is given by the value of ubntFansCount." ::= { ubntFans 2 } ubntFanEntry OBJECT-TYPE SYNTAX UbntFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ubntFansTable." INDEX { ubntFanIndex } ::= { ubntFansTable 1 } UbntFanEntry ::= SEQUENCE { ubntFanIndex Integer32, ubntFanType Integer32, ubntFanRpm Integer32 } ubntFanIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for fan." ::= { ubntFanEntry 1 } ubntFanType OBJECT-TYPE SYNTAX INTEGER { other(0), board(1), cpu(2), power(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of fan." ::= { ubntFanEntry 2 } ubntFanRpm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Fan RPM." ::= { ubntFanEntry 3 } END