-- ZyXEL Communications Corporation -- Private Enterprise MIB definition -- $Log: zyxel-AS.mib $ -- Revision 1.2 2006/06/08 09:18:11 niceguy -- Revision 1.1 2005/11/23 12:47:58 niceguy -- Initial revision -- Revision 1.1 2005/08/18 13:30:38 Jeff -- Initial revision -- Revision 1.12 2004/06/08 10:12:38 jenny -- Revision 1.11 2004/05/05 08:33:35 jennyhsu -- Revision 1.10 2004/01/29 03:41:26 jennyhsu -- Define DHCP option 82 setting -- Revision 1.9 2003/09/19 04:57:58 jennyhsu -- Add thermalSensorFailure trap. Change the syntax of -- asDhcpRelayOption82Info to be DisplayString -- Revision 1.8 2003/09/10 12:26:16 jennyhsu -- add DHCP setup -- Revision 1.7 2003/06/06 09:15:18 jennyhsu -- Revise the descriptions of accessSwitchDSLConfTarget -- Revision 1.6 2003/06/06 01:39:28 jennyhsu -- Add objects for DSL configuration in batch mode -- Revision 1.5 2003/05/27 08:12:45 jennyhsu -- Add asPacketForwardingTable -- Revision 1.4 2003/03/21 06:57:38 jennyhsu -- remove the mask of accessSwitchSystemTemperature -- Revision 1.3 2002/12/03 07:49:00 jennyhsu -- Add accessSwitchSystemCurrentStatus into the variable binding of -- temp, fan and voltage trap -- Revision 1.2 2002/11/12 07:48:00 jennyhsu -- Revision 1.1 2002/11/12 07:40:49 jennyhsu -- Initial revision ZYXEL-AS-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex, PhysAddress FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 PortList FROM Q-BRIDGE-MIB RowStatus FROM SNMPv2-TC MacAddress, Timeout, BridgeId FROM BRIDGE-MIB; zyxel OBJECT IDENTIFIER ::= { enterprises 890 } products OBJECT IDENTIFIER ::= { zyxel 1 } accessSwitch OBJECT IDENTIFIER ::= { products 5 } -- accessSwitch generic managed objects accessSwitchCommon OBJECT IDENTIFIER ::= { accessSwitch 1 } accessSwitchMgnt OBJECT IDENTIFIER ::= { accessSwitchCommon 1 } accessSwitchStats OBJECT IDENTIFIER ::= { accessSwitchCommon 2 } asMacStats OBJECT IDENTIFIER ::= { accessSwitchStats 1 } -- accessSwitchMgnt subtree -- System Status accessSwitchSystemCurrentStatus OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of the system. The sysCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sysNoDefect 2 sysOverHeat 3 sysFanRpmLow 4 sysVoltageLow 5 sysThermalSensorFailure" ::= { accessSwitchMgnt 1 } -- System traps related managed objects accessSwitchProblemCause OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The variable is the description of sytsem problem." ::= { accessSwitchMgnt 2 } -- For AES-100, IES-1000 (SAM1008, AAM1008) only accessSwitchSystemTemperature OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The variable is the current temperature in Celsius of the system." ::= { accessSwitchMgnt 3 } -- Fan rpm table accessSwitchFanRpmTable OBJECT-TYPE SYNTAX SEQUENCE OF AccessSwitchFanRpmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains rpm information about the fans." ::= { accessSwitchMgnt 4 } accessSwitchFanRpmEntry OBJECT-TYPE SYNTAX AccessSwitchFanRpmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of rpm information for each fan." INDEX { accessSwitchFanRpmIndex } ::= { accessSwitchFanRpmTable 1 } AccessSwitchFanRpmEntry ::= SEQUENCE { accessSwitchFanRpmIndex INTEGER, accessSwitchFanRpmCurValue INTEGER, accessSwitchFanRpmMaxValue INTEGER, accessSwitchFanRpmMinValue INTEGER, accessSwitchFanRpmLowThresh INTEGER, accessSwitchFanRpmDescr DisplayString } accessSwitchFanRpmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identity of the fan." ::= { accessSwitchFanRpmEntry 1 } accessSwitchFanRpmCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current rpm of the fan." ::= { accessSwitchFanRpmEntry 2 } accessSwitchFanRpmMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum rpm ever performed by the fan." ::= { accessSwitchFanRpmEntry 3 } accessSwitchFanRpmMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum rpm ever performed by the fan." ::= { accessSwitchFanRpmEntry 4 } accessSwitchFanRpmLowThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The low threshold of the rpm of the fan. If the current rpm is less than the threshold, the device will initiate the fanRpmLow trap." ::= { accessSwitchFanRpmEntry 5 } accessSwitchFanRpmDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the fan (e.g. location, function, etc.)." ::= { accessSwitchFanRpmEntry 6 } -- Voltage table accessSwitchVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF AccessSwitchVoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains voltage information about the system." ::= { accessSwitchMgnt 5 } accessSwitchVoltageEntry OBJECT-TYPE SYNTAX AccessSwitchVoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of voltage information for each sensor." INDEX { accessSwitchVoltageIndex } ::= { accessSwitchVoltageTable 1 } AccessSwitchVoltageEntry ::= SEQUENCE { accessSwitchVoltageIndex INTEGER, accessSwitchVoltageCurValue INTEGER, accessSwitchVoltageMaxValue INTEGER, accessSwitchVoltageMinValue INTEGER, accessSwitchVoltageNominalValue INTEGER, accessSwitchVoltageLowThresh INTEGER, accessSwitchVoltageDescr DisplayString } accessSwitchVoltageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identity of the sensor." ::= { accessSwitchVoltageEntry 1 } accessSwitchVoltageCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current voltage detected by the sensor (in milli-voltage)." ::= { accessSwitchVoltageEntry 2 } accessSwitchVoltageMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum voltage ever detected by the sensor (in milli-voltage)." ::= { accessSwitchVoltageEntry 3 } accessSwitchVoltageMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum voltage ever detected by the sensor (in milli-voltage)." ::= { accessSwitchVoltageEntry 4 } accessSwitchVoltageNominalValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The nominal voltage which the power should supply (in milli-voltage)." ::= { accessSwitchVoltageEntry 5 } accessSwitchVoltageLowThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The low threshold of the voltage. If the current voltage is less than the threshold, the device will initiate the voltageLow trap." ::= { accessSwitchVoltageEntry 6 } accessSwitchVoltageDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the voltage (e.g. location, nominal value, etc.)." ::= { accessSwitchVoltageEntry 7 } -- System temperature table accessSwitchSysTempTable OBJECT-TYPE SYNTAX SEQUENCE OF AccessSwitchSysTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains temperature information about system." ::= { accessSwitchMgnt 6 } accessSwitchSysTempEntry OBJECT-TYPE SYNTAX AccessSwitchSysTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of temperature information for each sensor." INDEX { accessSwitchSysTempIndex } ::= { accessSwitchSysTempTable 1 } AccessSwitchSysTempEntry ::= SEQUENCE { accessSwitchSysTempIndex INTEGER, accessSwitchSysTempCurValue INTEGER, accessSwitchSysTempMaxValue INTEGER, accessSwitchSysTempMinValue INTEGER, accessSwitchSysTempHighThresh INTEGER, accessSwitchSysTempDescr DisplayString } accessSwitchSysTempIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identity of the sensor." ::= { accessSwitchSysTempEntry 1 } accessSwitchSysTempCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current temperature detected in Celsius by the sensor." ::= { accessSwitchSysTempEntry 2 } accessSwitchSysTempMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum temperature ever detected in Celsius by the sensor." ::= { accessSwitchSysTempEntry 3 } accessSwitchSysTempMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum temperature ever detected in Celsius by the sensor." ::= { accessSwitchSysTempEntry 4 } accessSwitchSysTempHighThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap." ::= { accessSwitchSysTempEntry 5 } accessSwitchSysTempDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the temperature sensor (e.g. location, function, etc.)." ::= { accessSwitchSysTempEntry 6 } accessSwitchMaintenance OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT 3: local loopback test BIT 4: remote loopback test" ::= { accessSwitchMgnt 7 } accessSwitchMaintenancePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The port which the maintenance operation should be performed on. The value of 0 means the maintenance should be performed on the system." ::= { accessSwitchMgnt 8 } accessSwitchMaxNumOfStaticVlans OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of static VLANs which the system supports" ::= { accessSwitchMgnt 9 } -- Chassis information ASSlotNum ::= INTEGER { slot1(1), slot2(2) } ASModuleType ::= INTEGER { aes-100(1), aes-100-1(2), aam1008-61(3), aam1008-63(4), sam1008(5) } acccessSwitchChassisId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The chassis Id of the module" ::= { accessSwitchMgnt 10 } accessSwitchSlotId OBJECT-TYPE SYNTAX ASSlotNum ACCESS read-write STATUS mandatory DESCRIPTION "The slot Id of the module" ::= { accessSwitchMgnt 11 } accessSwitchModuleType OBJECT-TYPE SYNTAX ASModuleType ACCESS read-only STATUS mandatory DESCRIPTION "The type of the module" ::= { accessSwitchMgnt 12 } accessSwitchFWVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version of the access switch." ::= { accessSwitchMgnt 13 } accessSwitchDriverVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The driver version of the access port in this access switch" ::= { accessSwitchMgnt 14 } accessSwitchModemCodeVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The modem code version of the access port in this access switch" ::= { accessSwitchMgnt 15 } -- variables for provisioning DSL line in batch mode accessSwitchDSLConfOps OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The managed object is for xDSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set DSL mode BIT 4: set profile" ::= { accessSwitchMgnt 16 } accessSwitchDSLConfTarget OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The managed object is used for identify the target on which the line configuration should be performed. The target is encoded as: Byte 1~4: reserved Byte 5~7: each octet specifies a set of eight ports, with the first octet specifying ports 1 through 8, etc. Byte 8~10: reserved" ::= { accessSwitchMgnt 17 } accessSwitchDSLConfProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The DSL profile name" ::= { accessSwitchMgnt 18 } accessSwitchDSLConfMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The DSL mode. The semantic for each bit is: Bit 1: ADSL, G.lite Bit 2: ADSL, G.dmt Bit 3: ADSL, T1.413 Bit 4: ADSL, Auto" ::= { accessSwitchMgnt 19 } -- Packet Forwarding Table asPacketForwardingTable OBJECT-TYPE SYNTAX SEQUENCE OF AsPacketForwardingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table includes the configuration of packet forwarding." ::= { accessSwitchMgnt 20 } asPacketForwardingEntry OBJECT-TYPE SYNTAX AsPacketForwardingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in asPacketForwardingTable." INDEX { ifIndex } ::= { asPacketForwardingTable 1 } AsPacketForwardingEntry ::= SEQUENCE { asPacketForwardingPortList PortList } asPacketForwardingPortList OBJECT-TYPE SYNTAX PortList ACCESS read-write STATUS mandatory DESCRIPTION "The list defines the ports to which the packets will be forwarded." ::= { asPacketForwardingEntry 1 } -- DHCP Setup asDhcpRelayEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable DHCP relay function." ::= { accessSwitchMgnt 21 } asDhcpRelayOption82Enable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable the relay agent information option." ::= { accessSwitchMgnt 22 } asDhcpRelayOption82Info OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User specific relay agent information." ::= { accessSwitchMgnt 23 } asMaxNumOfDhcpServers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of DHCP servers." ::= { accessSwitchMgnt 24 } asDhcpServerTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDhcpServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains DHCP server information." ::= { accessSwitchMgnt 25 } asDhcpServerEntry OBJECT-TYPE SYNTAX AsDhcpServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entry of DHCP server table." INDEX { asDhcpServerIp } ::= { asDhcpServerTable 1 } AsDhcpServerEntry ::= SEQUENCE { asDhcpServerIp IpAddress, asDhcpServerRowStatus RowStatus } asDhcpServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the DHCP server." ::= { asDhcpServerEntry 1 } asDhcpServerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The row status of the DHCP server entry." ::= { asDhcpServerEntry 2 } -- SNMP setup, Trap Destination -- asMaxNumberOfTrapDestinations OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The max number of the trap destinations." -- ::= { accessSwitchMgnt 26 } -- -- asSNMPTrapDestTable OBJECT-TYPE -- SYNTAX SEQUENCE OF AsSNMPTrapDestEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A table that contains SNMP trap destination information." -- ::= { accessSwitchMgnt 27 } -- asSNMPTrapDestEntry OBJECT-TYPE -- SYNTAX AsSNMPTrapDestEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "The entry of SNMP trap destination table." -- INDEX { asTrapDestIp, asTrapDestPort } -- ::= { asSNMPTrapDestTable 1 } -- AsSNMPTrapDestEntry ::= -- SEQUENCE { -- asTrapDestIp IpAddress, -- asTrapDestPort INTEGER, -- asTrapDestRowStatus RowStatus -- } -- asTrapDestIp OBJECT-TYPE -- SYNTAX IpAddress -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The IP address of the trap destination." -- ::= { asSNMPTrapDestEntry 1 } -- asTrapDestPort OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The UDP port of the trap destination." -- ::= { asSNMPTrapDestEntry 2 } -- asTrapDestRowStatus OBJECT-TYPE -- SYNTAX RowStatus -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The row status of the trap destination entry." -- ::= { asSNMPTrapDestEntry 3} -- RADIUS Server setup asMaxNumberOfRadiusServers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The max number of the RADIUS Servers." ::= { accessSwitchMgnt 28 } asRadiusServerTable OBJECT-TYPE SYNTAX SEQUENCE OF AsRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains Radius Server information." ::= { accessSwitchMgnt 29 } asRadiusServerEntry OBJECT-TYPE SYNTAX AsRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entry of Radius Server table." INDEX { asRadiusServerIndex } ::= { asRadiusServerTable 1 } AsRadiusServerEntry ::= SEQUENCE { asRadiusServerIndex INTEGER, asRadiusServerIp IpAddress, asRadiusServerPort INTEGER, asRadiusSharedSecret DisplayString, asRadiusServerRowStatus RowStatus } asRadiusServerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identity of the RADIUS server." ::= { asRadiusServerEntry 1 } asRadiusServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the Radius Server." ::= { asRadiusServerEntry 2 } asRadiusServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The UDP port of the Radius Server." ::= { asRadiusServerEntry 3 } asRadiusSharedSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The shared secret of the Radius Server." ::= { asRadiusServerEntry 4 } asRadiusServerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The row status of the Radius Server entry." ::= { asRadiusServerEntry 5 } -- 802.1x option asDot1xEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable the 802.1x function." ::= { accessSwitchMgnt 30 } -- 802.1x Table asDot1xPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDot1xPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table includes the configuration of 802.1x." ::= { accessSwitchMgnt 31 } asDot1xPortEntry OBJECT-TYPE SYNTAX AsDot1xPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in asDot1xPortTable." INDEX { ifIndex } ::= { asDot1xPortTable 1 } AsDot1xPortEntry ::= SEQUENCE { asDot1xPortEnable INTEGER, asDot1xPortControl INTEGER, asDot1xPortReAuthEnable INTEGER, asDot1xPortReAuthPeriod INTEGER } asDot1xPortEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The option defines if the port enables 802.1x settings." ::= { asDot1xPortEntry 1 } asDot1xPortControl OBJECT-TYPE SYNTAX INTEGER { auto(1), forceAuth(2), forceUnAuth(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The configuration defines the 802.1x port control type." ::= { asDot1xPortEntry 2 } asDot1xPortReAuthEnable OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The option defines if the port enables 802.1x re-authentication." ::= { asDot1xPortEntry 3 } asDot1xPortReAuthPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The configuration defines the 802.1x re-authentication period for each port." ::= { asDot1xPortEntry 4 } -------------------- -- Statistics -------------------- asMacDisplayTarget OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This managed object is a filter used for identify the target from which the MAC addresses are learned in macTable. The target should be IfIndex which is used for identifying subscriber ports (e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3)." ::= { asMacStats 1 } -- macTable asMacTable OBJECT-TYPE SYNTAX SEQUENCE OF AsMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains information about unicast entries for which the bridge has forwarding and/or filtering information. This information is used by the transparent bridging function in determining how to propagate a received frame." ::= { asMacStats 2 } asMacEntry OBJECT-TYPE SYNTAX AsMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of asMacTable." INDEX { asMacAddress } ::= { asMacTable 1 } AsMacEntry ::= SEQUENCE { asMacAddress MacAddress, asMacPort INTEGER, asMacStatus INTEGER } asMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "A unicast MAC address for which the bridge has forwarding and/or filtering information." ::= { asMacEntry 1 } asMacPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The port from which the mac address has been learned." ::= { asMacEntry 2 } asMacStatus OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), learned(3), self(4), mgmt(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this entry." ::= { asMacEntry 3 } -- accessSwitch specific traps reboot TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "Send a message to the manager that the system is going to reboot. The variable is the reason why the system reboots." ::= 1 systemShutdown TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "Send a message to the manager that the system is going to shutdown. The variable is the reason that causes the system to shutdown." ::= 2 overheat TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchSysTempIndex, accessSwitchSysTempCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the system is overheated. The variable in the binding list is the current temperature in Celsius of the system." ::= 3 overheatOver TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchSysTempIndex, accessSwitchSysTempCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the overheated condition is over. The variable in the binding list is the current temperature in Celsius of the system." ::= 4 errLog TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "Send a message to the manager that an error log is created in system. The variable in the binding list is the content of the error log." ::= 5 fanRpmLow TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchFanRpmIndex, accessSwitchFanRpmCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the rpm of the fan is too low. The variable in the binding list is the current rpm of the fan." ::= 6 fanRpmNormal TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchFanRpmIndex, accessSwitchFanRpmCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the low-rpm condition of the fan is over. The variable in the binding list is the current rpm of the fan." ::= 7 voltageOutOfRange TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchVoltageIndex, accessSwitchVoltageCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system." ::= 8 voltageNormal TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchVoltageIndex, accessSwitchVoltageCurValue, accessSwitchSystemCurrentStatus } DESCRIPTION "Send a message to the manager that the low-voltage condition is over. The variable in the binding list is the current voltage in volt of the system." ::= 9 systemMaintenanceFailure TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "Send a message to the manager that the system maintence operation fail. The variable in the variable binding indicates the problem." ::= 10 configChange TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "Send a message to the manager that the system configuration data is changed." ::= 11 thermalSensorFailure TRAP-TYPE ENTERPRISE accessSwitch VARIABLES { accessSwitchProblemCause } DESCRIPTION "The trap signifies that the thermal sensor failed." ::= 12 END