-- ZyXEL Communications Corporation -- Private Enterprise MIB definition -- This file describes the ZyXEL Communications Corporation Enterprise MIB. -- It contains ZyXEL products OIDs, and common managed objects. ZYXEL-MGS3712-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM SNMPv2-SMI -- RFC2578 RowStatus, DateAndTime, TruthValue, StorageType, MacAddress FROM SNMPv2-TC -- RFC2579 DisplayString FROM RFC1213-MIB EnabledStatus FROM P-BRIDGE-MIB PortList FROM Q-BRIDGE-MIB dot1dBasePort FROM BRIDGE-MIB InterfaceIndexOrZero -- RFC2863 FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- RFC2571 InetAddressType, InetAddress FROM INET-ADDRESS-MIB -- RFC2851 OperationResponseStatus FROM DISMAN-PING-MIB dot1agCfmMdIndex FROM IEEE8021-CFM-MIB dot1agCfmMaIndex FROM IEEE8021-CFM-MIB dot1agCfmMepIdentifier FROM IEEE8021-CFM-MIB IpAddress FROM SNMPv2-SMI ifIndex FROM IF-MIB -- from [RFC2863] NOTIFICATION-TYPE FROM SNMPv2-SMI sysObjectID FROM RFC1213-MIB Counter, TimeTicks FROM RFC1155-SMI BridgeId, Timeout FROM BRIDGE-MIB; zyxel OBJECT IDENTIFIER ::= { enterprises 890 } products OBJECT IDENTIFIER ::= { zyxel 1 } accessSwitch OBJECT IDENTIFIER ::= { products 5 } esSeries OBJECT IDENTIFIER ::= { accessSwitch 8 } mgs3712 OBJECT IDENTIFIER ::= { esSeries 47 } -- sysInfo sysInfo OBJECT IDENTIFIER ::= { mgs3712 1 } sysSwPlatformMajorVers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SW platform major version, e.g. 3." ::= { sysInfo 1 } sysSwPlatformMinorVers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SW platform minor version, e.g. 50." ::= { sysInfo 2 } sysSwModelString OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Model letters, e.g. TJ" ::= { sysInfo 3 } sysSwVersionControlNbr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Version control number, e.g. 0." ::= { sysInfo 4 } sysSwDay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SW compilation day, e.g. 19." ::= { sysInfo 5 } sysSwMonth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SW compilation month, e.g. 8." ::= { sysInfo 6 } sysSwYear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SW compilation year, e.g. 2004." ::= { sysInfo 7 } sysHwMajorVers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HW major version number, e.g. 1." ::= { sysInfo 8 } sysHwMinorVers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HW minor version number, e.g. 0." ::= { sysInfo 9 } sysSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Serial number" ::= { sysInfo 10 } sysSwBootUpImage OBJECT-TYPE SYNTAX INTEGER{ image_1(1), image_2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current system boot up image, You can change the boot up image of next rebooting by setting sysMgmtBootupImage." ::= { sysInfo 11 } -- rateLimitSetup rateLimitSetup OBJECT IDENTIFIER ::= { mgs3712 2 } rateLimitState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Ingress/egress rate limiting enabled/disabled for the switch." ::= { rateLimitSetup 1 } -- rateLimitPortTable rateLimitPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RateLimitPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { rateLimitSetup 2 } rateLimitPortEntry OBJECT-TYPE SYNTAX RateLimitPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in rateLimitPortTable." INDEX { dot1dBasePort } ::= { rateLimitPortTable 1 } RateLimitPortEntry ::= SEQUENCE { rateLimitPortState EnabledStatus, rateLimitPortPeakRate INTEGER, rateLimitPortEgrRate INTEGER, rateLimitPortCommitRate INTEGER, rateLimitPortPeakState EnabledStatus, rateLimitPortEgrState EnabledStatus, rateLimitPortCommitState EnabledStatus } rateLimitPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "This item can enabled/disabled Commit Rate, Peak Rate, and Egress Rate at the same time. It's meaningless while reading this entry." ::= { rateLimitPortEntry 1 } rateLimitPortPeakRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Peak rate in Kbit/s. The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000." ::= { rateLimitPortEntry 2 } rateLimitPortEgrRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Egress rate in Kbit/s. The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000." ::= { rateLimitPortEntry 3 } rateLimitPortCommitRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Commit rate in Kbit/s. The range of FE port is between 0 and 100,000. For GE port, the range is between 0 and 1000,000." ::= { rateLimitPortEntry 4 } rateLimitPortPeakState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Ingress peak rate limiting enabled/disabled on the port." ::= { rateLimitPortEntry 5 } rateLimitPortEgrState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Egress rate limiting enabled/disabled on the port." ::= { rateLimitPortEntry 6 } rateLimitPortCommitState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Ingress commit rate limiting enabled/disabled on the port." ::= { rateLimitPortEntry 7 } -- brLimitSetup brLimitSetup OBJECT IDENTIFIER ::= { mgs3712 3 } brLimitState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Broadcast/multicast/DLF rate limiting enabled/disabled for the switch." ::= { brLimitSetup 1 } -- brLimitPortTable brLimitPortTable OBJECT-TYPE SYNTAX SEQUENCE OF BrLimitPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { brLimitSetup 2 } brLimitPortEntry OBJECT-TYPE SYNTAX BrLimitPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in brLimitPortTable." INDEX { dot1dBasePort } ::= { brLimitPortTable 1 } BrLimitPortEntry ::= SEQUENCE { brLimitPortBrState EnabledStatus, brLimitPortBrRate INTEGER, brLimitPortMcState EnabledStatus, brLimitPortMcRate INTEGER, brLimitPortDlfState EnabledStatus, brLimitPortDlfRate INTEGER } brLimitPortBrState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Broadcast rate limiting enabled/disabled on the port." ::= { brLimitPortEntry 1 } brLimitPortBrRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allowed broadcast rate in pkts/s. For FE port, the maximum value is 148800. For GE port, the maximum value is 262143." ::= { brLimitPortEntry 2 } brLimitPortMcState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Multicast rate limiting enabled/disabled on the port." ::= { brLimitPortEntry 3 } brLimitPortMcRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "AAllowed mullticast rate in pkts/s. For FE port, the maximum value is 148800. For GE port, the maximum value is 262143." ::= { brLimitPortEntry 4 } brLimitPortDlfState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Destination lookup failure frames rate limiting enabled/disabled on the port." ::= { brLimitPortEntry 5 } brLimitPortDlfRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allowed destination lookup failure frames rate in pkts/s. For FE port, the maximum value is 148800. For GE port, the maximum value is 262143." ::= { brLimitPortEntry 6 } -- portSecuritySetup portSecuritySetup OBJECT IDENTIFIER ::= { mgs3712 4 } portSecurityState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portSecuritySetup 1 } portSecurityPortTable OBJECT-TYPE SYNTAX SEQUENCE OF PortSecurityPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { portSecuritySetup 2 } portSecurityPortEntry OBJECT-TYPE SYNTAX PortSecurityPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portSecurityPortTable." INDEX { dot1dBasePort } ::= { portSecurityPortTable 1 } PortSecurityPortEntry ::= SEQUENCE { portSecurityPortState EnabledStatus, portSecurityPortLearnState EnabledStatus, portSecurityPortCount INTEGER } portSecurityPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Port Security enabled/disabled on the port. Active(1) means this port only accept frames from static MAC addresses that are configured for the port, and dynamic MAC address frames up to the number specified by portSecurityPortCount object." ::= { portSecurityPortEntry 1 } portSecurityPortLearnState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "MAC address learning enabled/disable on the port." ::= { portSecurityPortEntry 2 } portSecurityPortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of (dynamic) MAC addresses that may be learned on the port." ::= { portSecurityPortEntry 3 } portSecurityMacFreeze OBJECT-TYPE SYNTAX PortList ACCESS read-write STATUS mandatory DESCRIPTION "This entry is used to execute MacFreeze action to port. It's meaningless while reading this entry." ::= { portSecuritySetup 3 } portSecurityVMLTable OBJECT-TYPE SYNTAX SEQUENCE OF PortSecurityVMLEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { portSecuritySetup 4 } portSecurityVMLEntry OBJECT-TYPE SYNTAX PortSecurityVMLEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portSecurityVMLTable." INDEX { portSecurityVMLPort, portSecurityVMLVID } ::= { portSecurityVMLTable 1 } PortSecurityVMLEntry ::= SEQUENCE { portSecurityVMLPort INTEGER, portSecurityVMLVID INTEGER, portSecurityVMLMacLimit INTEGER, portSecurityVMLRowStatus RowStatus } portSecurityVMLPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The configured port number of VLAN MAC Limit." ::= { portSecurityVMLEntry 1 } portSecurityVMLVID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The configured VLAN number of VLAN MAC Limit." ::= { portSecurityVMLEntry 2 } portSecurityVMLMacLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The MAC limit of specific port and VLAN." ::= { portSecurityVMLEntry 3 } portSecurityVMLRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { portSecurityVMLEntry 4 } -- vlanTrunkPortTable vlanTrunkSetup OBJECT IDENTIFIER ::= { mgs3712 5 } vlanTrunkPortTable OBJECT-TYPE SYNTAX SEQUENCE OF VlanTrunkPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { vlanTrunkSetup 1 } vlanTrunkPortEntry OBJECT-TYPE SYNTAX VlanTrunkPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in vlanTrunkPortTable." INDEX { dot1dBasePort } ::= { vlanTrunkPortTable 1 } VlanTrunkPortEntry ::= SEQUENCE { vlanTrunkPortState EnabledStatus } vlanTrunkPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "VlanTrunking enabled/disabled on the port. Active(1) to allow frames belonging to unknown VLAN groups to pass through the switch." ::= { vlanTrunkPortEntry 1 } -- ctlProtTransSetup ctlProtTransSetup OBJECT IDENTIFIER ::= { mgs3712 6 } ctlProtTransState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Bridge control protocol transparency enabled/disabled for the switch" ::= { ctlProtTransSetup 1 } -- ctlProtTransTunnelPortTable ctlProtTransTunnelPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CtlProtTransTunnelPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { ctlProtTransSetup 2 } ctlProtTransTunnelPortEntry OBJECT-TYPE SYNTAX CtlProtTransTunnelPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in ctlProtTransTunnelPortTable." INDEX { dot1dBasePort } ::= { ctlProtTransTunnelPortTable 1 } CtlProtTransTunnelPortEntry ::= SEQUENCE { ctlProtTransTunnelMode INTEGER } ctlProtTransTunnelMode OBJECT-TYPE SYNTAX INTEGER{ peer(0), tunnel(1), discard(2), network(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Bridge control protocol transparency mode for the port. Modes: Peer(0), Tunnel(1), Discard(2), Network(3)" ::= { ctlProtTransTunnelPortEntry 1 } --------------------------------------------------------------------- -- -- dot1x Setup -- -- for AAA Service -- 1. rename radius8021xSetup as dot1xSetup -- 2. remove radiusLoginPrecedence (AAA Service: authentication login) -- 3. remove radiusAnd8021xServer (AAA Service: radius server setup) -- 4. DO NOT change oid for backward compatible -- --------------------------------------------------------------------- -- dot1xSetup dot1xSetup OBJECT IDENTIFIER ::= { mgs3712 7 } -- portAuthState portAuthState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "802.1x port authentication enabled/disabled for the switch." ::= { dot1xSetup 3 } -- portAuthTable portAuthTable OBJECT-TYPE SYNTAX SEQUENCE OF PortAuthEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dot1xSetup 4 } portAuthEntry OBJECT-TYPE SYNTAX PortAuthEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portAuthTable." INDEX { dot1dBasePort } ::= { portAuthTable 1 } PortAuthEntry ::= SEQUENCE { portAuthEntryState EnabledStatus, portReAuthEntryState EnabledStatus, portReAuthEntryTimer INTEGER } portAuthEntryState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "802.1x port authentication enabled or disabled on the port." ::= { portAuthEntry 1 } portReAuthEntryState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "802.1x port re-authentication enabled or disabled on the port." ::= { portAuthEntry 2 } portReAuthEntryTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Re-authentication timer in seconds." ::= { portAuthEntry 3 } -- hardwareInfo hwMonitorInfo OBJECT IDENTIFIER ::= { mgs3712 8 } -- fabRpmTable fanRpmTable OBJECT-TYPE SYNTAX SEQUENCE OF FanRpmEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwMonitorInfo 1 } fanRpmEntry OBJECT-TYPE SYNTAX FanRpmEntry ACCESS not-accessible STATUS current DESCRIPTION "An entry in fanRpmTable." INDEX { fanRpmIndex } ::= { fanRpmTable 1 } FanRpmEntry ::= SEQUENCE { fanRpmIndex INTEGER, fanRpmCurValue INTEGER, fanRpmMaxValue INTEGER, fanRpmMinValue INTEGER, fanRpmLowThresh INTEGER, fanRpmDescr DisplayString } fanRpmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Index of FAN." ::= { fanRpmEntry 1 } fanRpmCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Current speed in Revolutions Per Minute (RPM) on the fan." ::= { fanRpmEntry 2 } fanRpmMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Maximum speed measured in Revolutions Per Minute (RPM) on the fan." ::= { fanRpmEntry 3 } fanRpmMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Minimum speed measured in Revolutions Per Minute (RPM) on the fan." ::= { fanRpmEntry 4 } fanRpmLowThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The minimum speed at which a normal fan should work." ::= { fanRpmEntry 5 } fanRpmDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "'Normal' indicates that this fan is functioning above the minimum speed. 'Error' indicates that this fan is functioning below the minimum speed." ::= { fanRpmEntry 6 } -- tempTable tempTable OBJECT-TYPE SYNTAX SEQUENCE OF TempEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwMonitorInfo 2 } tempEntry OBJECT-TYPE SYNTAX TempEntry ACCESS not-accessible STATUS current DESCRIPTION "An entry in tempTable." INDEX { tempIndex } ::= { tempTable 1 } TempEntry ::= SEQUENCE { tempIndex INTEGER, tempCurValue INTEGER, tempMaxValue INTEGER, tempMinValue INTEGER, tempHighThresh INTEGER, tempDescr DisplayString } tempIndex OBJECT-TYPE SYNTAX INTEGER { mac (1), cpu (2), phy (3) } ACCESS read-only STATUS current DESCRIPTION "Index of temperature unit. 1:MAC, 2:CPU, 3:PHY" ::= { tempEntry 1 } tempCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The current temperature measured at this sensor." ::= { tempEntry 2 } tempMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The maximum temperature measured at this sensor." ::= { tempEntry 3 } tempMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The minimum temperature measured at this sensor." ::= { tempEntry 4 } tempHighThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The upper temperature limit at this sensor." ::= { tempEntry 5 } tempDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "'Normal' indicates temperatures below the threshold and 'Error' for those above." ::= { tempEntry 6 } -- voltageTable voltageTable OBJECT-TYPE SYNTAX SEQUENCE OF VoltageEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwMonitorInfo 3 } voltageEntry OBJECT-TYPE SYNTAX VoltageEntry ACCESS not-accessible STATUS current DESCRIPTION "An entry in voltageTable." INDEX { voltageIndex } ::= { voltageTable 1 } VoltageEntry ::= SEQUENCE { voltageIndex INTEGER, voltageCurValue INTEGER, voltageMaxValue INTEGER, voltageMinValue INTEGER, voltageNominalValue INTEGER, voltageLowThresh INTEGER, voltageDescr DisplayString } voltageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Index of voltage." ::= { voltageEntry 1 } voltageCurValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The current voltage reading." ::= { voltageEntry 2 } voltageMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The maximum voltage measured at this point." ::= { voltageEntry 3 } voltageMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The minimum voltage measured at this point." ::= { voltageEntry 4 } voltageNominalValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The normal voltage at wchich the switch work." ::= { voltageEntry 5 } voltageLowThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "The minimum voltage at which the switch should work." ::= { voltageEntry 6 } voltageDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "'Normal' indicates that the voltage is within an acceptable operating range at this point; otherwise 'Error' is displayed." ::= { voltageEntry 7 } -- snmpSetup snmpSetup OBJECT IDENTIFIER ::= { mgs3712 9 } snmpGetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpSetup 1 } snmpSetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpSetup 2 } snmpTrapCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpSetup 3 } -- snmpTrapDestTable snmpTrapDestTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpTrapDestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { snmpSetup 4 } snmpTrapDestEntry OBJECT-TYPE SYNTAX SnmpTrapDestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in snmpTrapDestTable." INDEX { snmpTrapDestIP } ::= { snmpTrapDestTable 1 } SnmpTrapDestEntry ::= SEQUENCE { snmpTrapDestIP IpAddress, snmpTrapDestRowStatus RowStatus, snmpTrapDestPort INTEGER, snmpTrapVersion INTEGER, snmpTrapUserName DisplayString } snmpTrapDestIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of trap destination." ::= { snmpTrapDestEntry 1 } snmpTrapDestRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { snmpTrapDestEntry 2 } snmpTrapDestPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The UDP port of the trap destination." ::= { snmpTrapDestEntry 3 } snmpTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(0), v2c(1), v3(2) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The SNMP protocol version to send traps." ::= { snmpTrapDestEntry 4 } snmpTrapUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The user name for sending SNMPv3 traps." ::= { snmpTrapDestEntry 5 } --snmpVersion snmpVersion OBJECT-TYPE SYNTAX INTEGER { v2c(0), v3(1), v3v2c(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The SNMP version to be used. v3v2c means that the manager can get/set by SNMPv3 and can get by SNMPv2c." ::= { snmpSetup 5 } -- snmpUserTable snmpUserTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains SNMPv3 user information." ::= { snmpSetup 6 } snmpUserEntry OBJECT-TYPE SYNTAX SnmpUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of snmpUserTable." INDEX { snmpUserName } ::= { snmpUserTable 1 } SnmpUserEntry ::= SEQUENCE { snmpUserName DisplayString, snmpUserSecurityLevel INTEGER, snmpUserAuthProtocol INTEGER, snmpUserPrivProtocol INTEGER } snmpUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user name." ::= { snmpUserEntry 1 } snmpUserSecurityLevel OBJECT-TYPE SYNTAX INTEGER { noAuthNoPriv(0), authNoPriv(1), authPriv(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The level of security at which SNMP messages can be sent or with which operations are being processed." ::= { snmpUserEntry 2 } snmpUserAuthProtocol OBJECT-TYPE SYNTAX INTEGER { md5(0), sha(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of authentication protocol to be used." ::= { snmpUserEntry 3 } snmpUserPrivProtocol OBJECT-TYPE SYNTAX INTEGER { des(0), aes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of privacy protocol to be used." ::= { snmpUserEntry 4 } -- snmpTrapGroupTable snmpTrapGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpTrapGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { snmpSetup 7 } snmpTrapGroupEntry OBJECT-TYPE SYNTAX SnmpTrapGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in snmpTrapGroupTable." INDEX { snmpTrapDestIP } ::= { snmpTrapGroupTable 1 } SnmpTrapGroupEntry ::= SEQUENCE { snmpTrapSystemGroup BITS, snmpTrapInterfaceGroup BITS, snmpTrapAAAGroup BITS, snmpTrapIPGroup BITS, snmpTrapSwitchGroup BITS } snmpTrapSystemGroup OBJECT-TYPE SYNTAX BITS { coldStart(0), warmStart(1), fanSpeed(2), temperature(3), voltage(4), reset (5), timeSync (6), intrusionlock(7), loopGuard(13), externalalarm(10) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpTrapGroupEntry 1 } snmpTrapInterfaceGroup OBJECT-TYPE SYNTAX BITS { linkup(0), linkdown(1), autonegotiation(2), lldp(3), transceiver-ddm(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpTrapGroupEntry 2 } snmpTrapAAAGroup OBJECT-TYPE SYNTAX BITS { authentication(0), accounting(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpTrapGroupEntry 3 } snmpTrapIPGroup OBJECT-TYPE SYNTAX BITS { ping(0), traceroute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpTrapGroupEntry 4 } snmpTrapSwitchGroup OBJECT-TYPE SYNTAX BITS { stp(0), mactable(1), rmon(2), cfm(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { snmpTrapGroupEntry 5 } -- dateTimeSetup dateTimeSetup OBJECT IDENTIFIER ::= { mgs3712 10 } dateTimeServerType OBJECT-TYPE SYNTAX INTEGER { none(1), daytime(2), time(3), ntp(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The time service protocol." ::= { dateTimeSetup 1 } dateTimeServerIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of time server." ::= { dateTimeSetup 2 } dateTimeZone OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time difference between UTC. Ex: +01" ::= { dateTimeSetup 3 } dateTimeNewDateYear OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new date in year." ::= { dateTimeSetup 4 } dateTimeNewDateMonth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new date in month." ::= { dateTimeSetup 5 } dateTimeNewDateDay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new date in day." ::= { dateTimeSetup 6 } dateTimeNewTimeHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new time in hour." ::= { dateTimeSetup 7 } dateTimeNewTimeMinute OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new time in minute." ::= { dateTimeSetup 8 } dateTimeNewTimeSecond OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The new time in second." ::= { dateTimeSetup 9 } -- dateTimeDaylightSavingTimeSetup OBJECT-TYPE dateTimeDaylightSavingTimeSetup OBJECT IDENTIFIER ::= { dateTimeSetup 10 } daylightSavingTimeState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service enabled/disabled for the switch." ::= { dateTimeDaylightSavingTimeSetup 1 } daylightSavingTimeStartDateWeek OBJECT-TYPE SYNTAX INTEGER { first(1), second(2), third(3), fourth(4), last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service start week." ::= { dateTimeDaylightSavingTimeSetup 2 } daylightSavingTimeStartDateDay OBJECT-TYPE SYNTAX INTEGER { sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service start day." ::= { dateTimeDaylightSavingTimeSetup 3 } daylightSavingTimeStartDateMonth OBJECT-TYPE SYNTAX INTEGER { january(1), february(2), march(3), april(4), may(5), june(6), july(7), august(8), september(9), october(10), november(11), december(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service start month." ::= { dateTimeDaylightSavingTimeSetup 4 } daylightSavingTimeStartDateHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service start time." ::= { dateTimeDaylightSavingTimeSetup 5 } daylightSavingTimeEndDateWeek OBJECT-TYPE SYNTAX INTEGER { first(1), second(2), third(3), fourth(4), last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service end week." ::= { dateTimeDaylightSavingTimeSetup 6 } daylightSavingTimeEndDateDay OBJECT-TYPE SYNTAX INTEGER { sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service end day." ::= { dateTimeDaylightSavingTimeSetup 7 } daylightSavingTimeEndDateMonth OBJECT-TYPE SYNTAX INTEGER { january(1), february(2), march(3), april(4), may(5), june(6), july(7), august(8), september(9), october(10), november(11), december(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service end month." ::= { dateTimeDaylightSavingTimeSetup 8 } daylightSavingTimeEndDateHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daylight saving time service end time." ::= { dateTimeDaylightSavingTimeSetup 9 } -- sysMgmt sysMgmt OBJECT IDENTIFIER ::= { mgs3712 11 } sysMgmtConfigSave OBJECT-TYPE SYNTAX INTEGER { config_1(1), config_2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file. If not, running-config will be written to the booting one." ::= { sysMgmt 1 } sysMgmtBootupConfig OBJECT-TYPE SYNTAX INTEGER { config_1(1), config_2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The setting value (read index) will be written into non-volatile memory. While rebooting, the variable write index is equal to read index initially. You can change the value of write index by CLI / MIB." ::= { sysMgmt 2 } sysMgmtReboot OBJECT-TYPE SYNTAX INTEGER { nothing(0), reboot(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reboot switch from SNMP. 1:Reboot, 0:Nothing" ::= { sysMgmt 3 } sysMgmtDefaultConfig OBJECT-TYPE SYNTAX INTEGER { nothing(0), reset_to_default(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Erase running config and reset to default." ::= { sysMgmt 4 } sysMgmtLastActionStatus OBJECT-TYPE SYNTAX INTEGER { none(0), success(1), fail(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Display status of last mgmt action." ::= { sysMgmt 5 } sysMgmtSystemStatus OBJECT-TYPE SYNTAX BITS { sysAlarmDetected(0), sysTemperatureError(1), sysFanRPMError(2), sysVoltageRangeError(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of the system. The sysMgmtAlarmStatus is a bit map represented a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 0 sysAlarmDetected 1 sysTemperatureError 2 sysFanRPMError 3 sysVoltageRangeError" ::= { sysMgmt 6 } sysMgmtCPUUsage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Show device CPU load in %, it's the snapshot of CPU load when getting the values." ::= { sysMgmt 7 } sysMgmtBootupImage OBJECT-TYPE SYNTAX INTEGER { image_1(1), image_2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The setting value (read index) will be written into non-volatile memory. When rebooting, the selected image will be used. You can change the value of write index by CLI / MIB." ::= { sysMgmt 8 } sysMgmtCounterReset OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all port counters." ::= { sysMgmt 9 } -- Tftp service sysMgmtTftpServiceSetup OBJECT IDENTIFIER ::= { sysMgmt 10 } sysMgmtTftpServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " IP address of TFTP server" ::= { sysMgmtTftpServiceSetup 1 } sysMgmtTftpRemoteFileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The file name that you want to backup to or restore from TFTP server" ::= { sysMgmtTftpServiceSetup 2 } sysMgmtTftpConfigIndex OBJECT-TYPE SYNTAX INTEGER { config_1(1), config_2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Index of system configuration which you want to restore." ::= { sysMgmtTftpServiceSetup 3 } sysMgmtTftpAction OBJECT-TYPE SYNTAX INTEGER { none(0), backup_config(1), restore_config(2) } ACCESS read-write STATUS mandatory DESCRIPTION " Action of tftp service. 1: Backup running-config to tftp server, 2: Restore config from tftp server." ::= { sysMgmtTftpServiceSetup 4 } sysMgmtTftpActionStatus OBJECT-TYPE SYNTAX INTEGER { none(0), success(1), fail(2), under-action(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Display status of mgmt action." ::= { sysMgmtTftpServiceSetup 5 } -- layer2Setup layer2Setup OBJECT IDENTIFIER ::= { mgs3712 12 } vlanTypeSetup OBJECT-TYPE SYNTAX INTEGER { dot1Q(1), port_based(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 1 } igmpSnoopingStateSetup OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 2 } tagVlanPortIsolationState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 3 } stpState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 4 } igmpFilteringStateSetup OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 6 } unknownMulticastFrameForwarding OBJECT-TYPE SYNTAX INTEGER { flooding(1), drop(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 7 } multicastGrpHostTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specify host timeout for all multicast groups when the specific port is in auto mode." ::= { layer2Setup 8 } reservedMulticastFrameForwarding OBJECT-TYPE SYNTAX INTEGER { flooding(1), drop(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 10 } igmpsnp8021pPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set the 802.1p priority of control messages for igmp-snooping(0~8, 8-No Change)" ::= { layer2Setup 11 } igmpsnpVlanMode OBJECT-TYPE SYNTAX INTEGER { auto(1), fixed(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 12 } stpMode OBJECT-TYPE SYNTAX INTEGER { rstp(1), mrstp(2), mstp (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 13 } -- igmpsnpVlanTable igmpsnpVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpsnpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { layer2Setup 14 } igmpsnpVlanEntry OBJECT-TYPE SYNTAX IgmpsnpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in IgmpsnpVlanTable." INDEX { igmpsnpVid } ::= { igmpsnpVlanTable 1 } IgmpsnpVlanEntry ::= SEQUENCE { igmpsnpVid INTEGER, igmpsnpVlanName DisplayString, igmpsnpVlanRowStatus RowStatus } igmpsnpVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpsnpVlanEntry 1 } igmpsnpVlanName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { igmpsnpVlanEntry 2 } igmpsnpVlanRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { igmpsnpVlanEntry 3 } igmpsnpQuerierMode OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 15 } ethernetCfmStateSetup OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { layer2Setup 16 } -- ipSetup ipSetup OBJECT IDENTIFIER ::= { mgs3712 13 } dnsIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { ipSetup 1 } defaultMgmt OBJECT-TYPE SYNTAX INTEGER { in_band(0), out_of_band(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { ipSetup 2 } inbandIpSetup OBJECT IDENTIFIER ::= { ipSetup 3 } inbandIpType OBJECT-TYPE SYNTAX INTEGER { dhcp_client(0), static_ip(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpSetup 1 } inbandVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpSetup 2 } inbandStaticIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpSetup 3 } inbandStaticSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpSetup 4 } inbandStaticGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpSetup 5 } outOfBandIpSetup OBJECT IDENTIFIER ::= { ipSetup 4 } outOfBandIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { outOfBandIpSetup 1 } outOfBandSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { outOfBandIpSetup 2 } outOfBandGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { outOfBandIpSetup 3 } maxNumOfInbandIp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { ipSetup 5 } -- inbandIpTable inbandIpTable OBJECT-TYPE SYNTAX SEQUENCE OF InbandIpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { ipSetup 6 } inbandIpEntry OBJECT-TYPE SYNTAX InbandIpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in inbandIpTable." INDEX { inbandEntryIp, inbandEntryVid } ::= { inbandIpTable 1 } InbandIpEntry ::= SEQUENCE { inbandEntryIp IpAddress, inbandEntrySubnetMask IpAddress, inbandEntryGateway IpAddress, inbandEntryVid INTEGER, inbandEntryRowStatus RowStatus } inbandEntryIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { inbandIpEntry 1 } inbandEntrySubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpEntry 2 } inbandEntryGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { inbandIpEntry 3 } inbandEntryVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { inbandIpEntry 4 } inbandEntryRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { inbandIpEntry 6 } -- filterSetup filterSetup OBJECT IDENTIFIER ::= { mgs3712 14 } -- filterTable filterTable OBJECT-TYPE SYNTAX SEQUENCE OF FilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { filterSetup 1 } filterEntry OBJECT-TYPE SYNTAX FilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in filterTable." INDEX { filterMacAddr, filterVid } ::= { filterTable 1 } FilterEntry ::= SEQUENCE { filterName DisplayString, filterActionState INTEGER, filterMacAddr MacAddress, filterVid INTEGER, filterRowStatus RowStatus } filterName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { filterEntry 1 } filterActionState OBJECT-TYPE SYNTAX INTEGER { discard_source(1), discard_destination(2), both(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { filterEntry 2 } filterMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { filterEntry 3 } filterVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { filterEntry 4 } filterRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { filterEntry 5 } -- mirrorSetup mirrorSetup OBJECT IDENTIFIER ::= { mgs3712 15 } -- mirrorState mirrorState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mirrorSetup 1 } mirrorMonitorPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mirrorSetup 2 } -- mirrorTable mirrorTable OBJECT-TYPE SYNTAX SEQUENCE OF MirrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { mirrorSetup 3 } mirrorEntry OBJECT-TYPE SYNTAX MirrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in mirrorTable." INDEX { dot1dBasePort } ::= { mirrorTable 1 } MirrorEntry ::= SEQUENCE { mirrorMirroredState EnabledStatus, mirrorDirection INTEGER } mirrorMirroredState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mirrorEntry 1 } mirrorDirection OBJECT-TYPE SYNTAX INTEGER { ingress(0), egress(1), both(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mirrorEntry 2 } -- aggrSetup aggrSetup OBJECT IDENTIFIER ::= { mgs3712 16 } aggrState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrSetup 1 } aggrSystemPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrSetup 2 } -- aggrGroupTable aggrGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AggrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { aggrSetup 3 } aggrGroupEntry OBJECT-TYPE SYNTAX AggrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in aggrGroupTable." INDEX { aggrGroupIndex } ::= { aggrGroupTable 1 } AggrGroupEntry ::= SEQUENCE { aggrGroupIndex INTEGER, aggrGroupState EnabledStatus, aggrGroupDynamicState EnabledStatus, aggrGroupCriteria INTEGER } aggrGroupIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { aggrGroupEntry 1 } aggrGroupState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrGroupEntry 2 } aggrGroupDynamicState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrGroupEntry 3 } aggrGroupCriteria OBJECT-TYPE SYNTAX INTEGER { src-mac (1), dst-mac (2), src-dst-mac (3), src-ip (4), dst-ip (5), src-dst-ip (6) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrGroupEntry 4 } -- aggrPortTable aggrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AggrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { aggrSetup 4 } aggrPortEntry OBJECT-TYPE SYNTAX AggrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in aggrPortTable." INDEX { dot1dBasePort } ::= { aggrPortTable 1 } AggrPortEntry ::= SEQUENCE { aggrPortGroup INTEGER, aggrPortDynamicStateTimeout INTEGER } aggrPortGroup OBJECT-TYPE SYNTAX INTEGER { none(0), t1(1), t2(2), t3(3), t4(4), t5(5), t6(6) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrPortEntry 1 } aggrPortDynamicStateTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { aggrPortEntry 2 } -- accessCtlSetup accessCtlSetup OBJECT IDENTIFIER ::= { mgs3712 17 } -- accessCtlTable accessCtlTable OBJECT-TYPE SYNTAX SEQUENCE OF AccessCtlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { accessCtlSetup 1 } accessCtlEntry OBJECT-TYPE SYNTAX AccessCtlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in accessCtlTable." INDEX { accessCtlService } ::= { accessCtlTable 1 } AccessCtlEntry ::= SEQUENCE { accessCtlService INTEGER, accessCtlEnable EnabledStatus, accessCtlServicePort INTEGER, accessCtlTimeout INTEGER } accessCtlService OBJECT-TYPE SYNTAX INTEGER { telnet(1), ssh(2), ftp(3), http(4), https(5), icmp(6), snmp(7) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { accessCtlEntry 1 } accessCtlEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accessCtlEntry 2 } accessCtlServicePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accessCtlEntry 3 } accessCtlTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accessCtlEntry 4 } -- securedClientTable securedClientTable OBJECT-TYPE SYNTAX SEQUENCE OF SecuredClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { accessCtlSetup 2 } securedClientEntry OBJECT-TYPE SYNTAX SecuredClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in securedClientTable." INDEX { securedClientIndex } ::= { securedClientTable 1 } SecuredClientEntry ::= SEQUENCE { securedClientIndex INTEGER, securedClientEnable EnabledStatus, securedClientStartIp IpAddress, securedClientEndIp IpAddress, securedClientService BITS } securedClientIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { securedClientEntry 1 } securedClientEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { securedClientEntry 2 } securedClientStartIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { securedClientEntry 3 } securedClientEndIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { securedClientEntry 4 } securedClientService OBJECT-TYPE SYNTAX BITS { telnet(0), ftp(1), http(2), icmp(3), snmp(4), ssh(5), https(6) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { securedClientEntry 5 } -- queuingMethodSetup queuingMethodSetup OBJECT IDENTIFIER ::= { mgs3712 18 } -- portQueuingMethodTable portQueuingMethodTable OBJECT-TYPE SYNTAX SEQUENCE OF PortQueuingMethodEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { queuingMethodSetup 1 } portQueuingMethodEntry OBJECT-TYPE SYNTAX PortQueuingMethodEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portQueuingMethodTable." INDEX { dot1dBasePort, portQueuingMethodQueue } ::= { portQueuingMethodTable 1 } PortQueuingMethodEntry ::= SEQUENCE { portQueuingMethodQueue INTEGER, portQueuingMethodWeight INTEGER, portQueuingMethodMode INTEGER } portQueuingMethodQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0...7" ::= { portQueuingMethodEntry 1 } portQueuingMethodWeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0...15" ::= { portQueuingMethodEntry 2 } portQueuingMethodMode OBJECT-TYPE SYNTAX INTEGER { strictly_priority(0), weighted_round_robin(1), weighted_fair_scheduling(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portQueuingMethodEntry 3 } -- portQueuingMethodHybridSpqTable portQueuingMethodHybridSpqTable OBJECT-TYPE SYNTAX SEQUENCE OF PortQueuingMethodHybridSpqEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { queuingMethodSetup 2 } portQueuingMethodHybridSpqEntry OBJECT-TYPE SYNTAX PortQueuingMethodHybridSpqEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portQueuingMethodHybridSpqTable." INDEX { dot1dBasePort } ::= {portQueuingMethodHybridSpqTable 1} PortQueuingMethodHybridSpqEntry ::= SEQUENCE { portQueuingMethodHybridSpq INTEGER } portQueuingMethodHybridSpq OBJECT-TYPE SYNTAX INTEGER { none(0), q0(1), q1(2), q2(3), q3(4), q4(5), q5(6), q6(7), q7(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the queues of SPQ while other queueing method working. The selected Qx and higher serve as SPQ, and the rest of others serve as configured queuing methods." ::= { portQueuingMethodHybridSpqEntry 1 } -- dhcpSetup dhcpSetup OBJECT IDENTIFIER ::= { mgs3712 19 } globalDhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 1 } globalDhcpRelayEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 1 } globalDhcpRelayOption82Enable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 2 } globalDhcpRelayInfoEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 3 } globalDhcpRelayInfoData OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 4 } -- globalDhcpRelayRemoteServer maxNumberOfGlobalDhcpRelayRemoteServer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 5 } -- globalDhcpRelayRemoteServerTable globalDhcpRelayRemoteServerTable OBJECT-TYPE SYNTAX SEQUENCE OF GlobalDhcpRelayRemoteServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelay 6 } globalDhcpRelayRemoteServerEntry OBJECT-TYPE SYNTAX GlobalDhcpRelayRemoteServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in globalDhcpRelayRemoteServerTable." INDEX { globalDhcpRelayRemoteServerIp } ::= { globalDhcpRelayRemoteServerTable 1 } GlobalDhcpRelayRemoteServerEntry ::= SEQUENCE { globalDhcpRelayRemoteServerIp IpAddress, globalDhcpRelayRemoteServerRowStatus RowStatus } globalDhcpRelayRemoteServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelayRemoteServerEntry 1 } globalDhcpRelayRemoteServerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { globalDhcpRelayRemoteServerEntry 2 } -- dhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 3 } dhcpRelayInfoData OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpRelay 1 } maxNumberOfDhcpRelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of DHCP relay entries that can be created. A value of 0 for this object implies that there exists settings for global DHCP relay." ::= { dhcpRelay 2 } maxNumberOfDhcpRelayRemoteServer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpRelay 3 } -- dhcpRelayRemoteServerTable dhcpRelayRemoteServerTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpRelayRemoteServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dhcpRelay 4 } dhcpRelayRemoteServerEntry OBJECT-TYPE SYNTAX DhcpRelayRemoteServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in dhcpRelayRemoteServerTable." INDEX { dhcpRelayVid, dhcpRelayRemoteServerIp } ::= { dhcpRelayRemoteServerTable 1 } DhcpRelayRemoteServerEntry ::= SEQUENCE { dhcpRelayVid INTEGER, dhcpRelayRemoteServerIp IpAddress, dhcpRelayRemoteServerRowStatus RowStatus } dhcpRelayVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpRelayRemoteServerEntry 1 } dhcpRelayRemoteServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpRelayRemoteServerEntry 2 } dhcpRelayRemoteServerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { dhcpRelayRemoteServerEntry 3 } -- dhcpRelayTable dhcpRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dhcpRelay 5 } dhcpRelayEntry OBJECT-TYPE SYNTAX DhcpRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in dhcpRelayTable." INDEX { dhcpRelayVid } ::= { dhcpRelayTable 1 } DhcpRelayEntry ::= SEQUENCE { dhcpRelayOption82Enable EnabledStatus, dhcpRelayInfoEnable EnabledStatus } dhcpRelayOption82Enable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpRelayEntry 1 } dhcpRelayInfoEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpRelayEntry 2 } -- staticRouteSetup staticRouteSetup OBJECT IDENTIFIER ::= { mgs3712 20 } maxNumberOfStaticRoutes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { staticRouteSetup 1 } -- staticRouteTable staticRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF StaticRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { staticRouteSetup 2 } staticRouteEntry OBJECT-TYPE SYNTAX StaticRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in staticRouteTable." INDEX { staticRouteIp, staticRouteMask } ::= { staticRouteTable 1 } StaticRouteEntry ::= SEQUENCE { staticRouteName DisplayString, staticRouteIp IpAddress, staticRouteMask IpAddress, staticRouteGateway IpAddress, staticRouteMetric INTEGER, staticRouteRowStatus RowStatus } staticRouteName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 1 } staticRouteIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 2 } staticRouteMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 3 } staticRouteGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 4 } staticRouteMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 5 } staticRouteRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { staticRouteEntry 6 } -- arpInfo arpInfo OBJECT IDENTIFIER ::= { mgs3712 21 } -- arpTable arpTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInfo 1 } arpEntry OBJECT-TYPE SYNTAX ArpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in arpTable." INDEX { arpIpAddr, arpMacVid } ::= { arpTable 1 } ArpEntry ::= SEQUENCE { arpIndex INTEGER, arpIpAddr IpAddress, arpMacAddr MacAddress, arpMacVid INTEGER, arpType INTEGER } arpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpEntry 1 } arpIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpEntry 2 } arpMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpEntry 3 } arpMacVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpEntry 4 } arpType OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2) } ACCESS read-only STATUS mandatory DESCRIPTION "1-static, 2-dynamic" ::= { arpEntry 5 } -- portOpModeSetup portOpModeSetup OBJECT IDENTIFIER ::= { mgs3712 22 } -- portOpModePortTable portOpModePortTable OBJECT-TYPE SYNTAX SEQUENCE OF PortOpModePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { portOpModeSetup 1 } portOpModePortEntry OBJECT-TYPE SYNTAX PortOpModePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portOpModePortTable." INDEX { dot1dBasePort } ::= { portOpModePortTable 1 } PortOpModePortEntry ::= SEQUENCE { portOpModePortSpeedDuplex INTEGER, portOpModePortFlowCntl INTEGER, portOpModePortName OCTET STRING, portOpModePortModuleType INTEGER, portOpModePortLinkUpType INTEGER, portOpModePortIntrusionLock EnabledStatus, portOpModePortLBTestStatus INTEGER, portOpModePortCounterReset INTEGER } portOpModePortSpeedDuplex OBJECT-TYPE SYNTAX INTEGER { auto(0), speed_10_half(1), speed_10_full(2), speed_100_half(3), speed_100_full(4), speed_1000_full(5) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 1 } portOpModePortFlowCntl OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 2 } portOpModePortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 3 } portOpModePortModuleType OBJECT-TYPE SYNTAX INTEGER { fast_ethernet_10_100(0), gigabit_ethernet_100_1000(1) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 4 } portOpModePortLinkUpType OBJECT-TYPE SYNTAX INTEGER { down(0), copper(1), fiber(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 5 } portOpModePortIntrusionLock OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portOpModePortEntry 6 } portOpModePortLBTestStatus OBJECT-TYPE SYNTAX INTEGER { none(0), under_testing(1), success(2), fail(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This entry display latest loopback test status of port while performing loopback test." ::= { portOpModePortEntry 7 } portOpModePortCounterReset OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This entry resets port counter." ::= { portOpModePortEntry 8 } -- portBasedVlanSetup portBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 23 } -- portBasedVlanPortListTable portBasedVlanPortListTable OBJECT-TYPE SYNTAX SEQUENCE OF PortBasedVlanPortListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { portBasedVlanSetup 1 } portBasedVlanPortListEntry OBJECT-TYPE SYNTAX PortBasedVlanPortListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portBasedVlanPortListTable." INDEX { dot1dBasePort } ::= { portBasedVlanPortListTable 1 } PortBasedVlanPortListEntry ::= SEQUENCE { portBasedVlanPortListMembers OCTET STRING } portBasedVlanPortListMembers OBJECT-TYPE SYNTAX PortList ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { portBasedVlanPortListEntry 1 } --fault MIB faultMIB MODULE-IDENTITY LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM ORGANIZATION "ZyXEL" CONTACT-INFO "" DESCRIPTION "Fault event table definitions" ::= { mgs3712 24 } -- ************************************************************************** -- Local Textual Conventions -- ************************************************************************** UtcTimeStamp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Universal Time Coordinated as a 32-bit value that designates the number of seconds since Jan 1, 1970 12:00AM." SYNTAX Unsigned32 EventIdNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention describes the index that uniquely identifies a fault event type in the entire system. Every fault event type, e.g. link down, has a unique EventIdNumber." SYNTAX Integer32 EventSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention describes the severity of a fault event. The decreasing order of severity is shown in the textual convention." SYNTAX INTEGER{ critical (1), major (2), minor (3), informational (4) } EventServiceAffective ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention indicates whether an event is immediately service affecting or not." SYNTAX INTEGER{ noServiceAffected (1), serviceAffected (2) } InstanceType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention describes the type of an instanceId associated with each event and by that means specifies how the instanceId variable should be intepreted. Various instanceId types are specified below to enable fault monitoring for different kind of devices from fixed configuration pizza boxes to multi chassis nodes. All instanceId types may not need to be used in every device type. Note also that instanceId semantics are element type dependent (e.g. different kind of interface naming conventions may be used) and thus instanceId usage may vary from element to element. ========================================================================= Type Description Example form of InstanceId ========================================================================= unknown (1) unknown type - Irrelevant- ------------------------------------------------------------------------- node (2) Associated with events originating from 1 the node. Used for general events that (Node number) can not be associated with any specific block. InstanceId value 1 is used for single node equipment. ------------------------------------------------------------------------- shelf (3) Associated with events originating from 1 the shelf. In the case of fixed (shelf number) configuration devices this type is used for events that are associated with the physical enclosure, e.g. faults related to fan etc. InstanceId value 1 is used for single self equipment. ------------------------------------------------------------------------- line (4) Associated with events originating from physical interfaces or associated components such as line cards. InstanceId usage examples for faults originating from: - Physical port: Simply port number, e.g. .......1 ------------------------------------------------------------------------- switch (5) Associated with events originating from 1 from a switch chip or a switch card. (switch number) For single switch equipment InstanceId value 1 is used, for multi swich nodes InstanceId semantics if for further study. ------------------------------------------------------------------------- lsp (6) Associated with events originating from 1 a particular lsp. (lsp index) NOTE: In this case the InstanceName contains the lsp name and InstanceId contains lsp index. ------------------------------------------------------------------------- l2Interface(7) Associated with events originating from - TBD - a particular layer 2 interface. Used for layer 2 related events such as L2 control protocol faults. InstanceId semantics is for further study. ------------------------------------------------------------------------- l3Interface(8) Associated with events originating from - TBD - a particular layer 3 interface. Used for layer 3 related events such as L3 control protocol faults. InstanceId semantics is for further study. ------------------------------------------------------------------------- rowIndex (9) Associated with events reporting about a 'logical' or conceptual table that consists of rows. The Instance Id is the index/key for a row in the table. The format of the Instance Id will simply be a series of decimal numbers seperated by a '.': =========================================================================" SYNTAX INTEGER { unknown (1), node (2), shelf (3), line (4), switch (5), lsp (6), l2Interface(7), l3Interface(8), rowIndex(9) } MstiOrCistInstanceIndex ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention is an extension of the MstiInstanceIndex convention. This extension permits the additional value of zero, which means Common and Internal Spanning Tree (CIST)." SYNTAX Integer32 (0..16) -- ***************************************************************************** -- Top level structure of this MIB. -- ***************************************************************************** eventObjects OBJECT IDENTIFIER ::= { faultMIB 1 } -- ***************************************************************************** -- Event Table -- -- Event table reports all currently active fault events. Only normal type of -- faults (i.e. faults that are not automatically and immediately cleared) are -- present in the event table. Delta faults (i.e. faults that are automatically -- cleared) are reported only by using trap messages. -- ***************************************************************************** eventTable OBJECT-TYPE SYNTAX SEQUENCE OF EventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of currently active fault events. All faults of normal type regardless of their severity level are recorded in the event table. When a normal type fault is cleared it is deleted from the event table." ::= { eventObjects 1 } eventEntry OBJECT-TYPE SYNTAX EventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information about an event in the event table." INDEX { eventSeqNum } ::= { eventTable 1 } EventEntry ::= SEQUENCE { eventSeqNum Integer32, eventEventId EventIdNumber, eventName DisplayString, eventInstanceType InstanceType, eventInstanceId DisplayString, eventInstanceName DisplayString, eventSeverity EventSeverity, eventSetTime UtcTimeStamp, eventDescription DisplayString, eventServAffective EventServiceAffective, eventInstanceIdNumber Integer32 } eventSeqNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the sequence number of an event. Sequence number is incremented monotonically starting from 0 until it reaches its maximum and wraps around back to 0. Sequence number is incremented when - the state of a normal type fault is set on (the same sequence number is present in the events table as well as in the trap that is sent to notify about the fault on event) - delta event occurs (sequence number present in trap message) - the state of a normal type fault is set off (sequence number present in trap that is sent to notify for clearing)." ::= { eventEntry 1 } eventEventId OBJECT-TYPE SYNTAX EventIdNumber MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the event ID which uniquely identifies the event in the entire system." ::= { eventEntry 2 } eventName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the name of the event, for example 'Ethernet Link Down'" ::= { eventEntry 3 } eventInstanceType OBJECT-TYPE SYNTAX InstanceType MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the type of InstanceId of a particular event in the event table. In brief the instanceType refers to the type of sub-component generating this event in the system, for example switch (5). For more details see the textual conventions section. AFFECTS: eventInstanceId, eventInstanceName" ::= { eventEntry 4 } eventInstanceId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the InstanceId of a particular event in the event current table. In brief the instanceId refers to the sub-component generating this event in the system, for example '1' for port 1. For more details see the textual conventions section. DEPENDS ON: eventInstanceType" ::= { eventEntry 5 } eventInstanceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is mainly used to store additional information about the sub-component that is generating an event. For example this field may specify what cooling fan is faulty. DEPENDS ON: eventInstanceType" ::= { eventEntry 6 } eventSeverity OBJECT-TYPE SYNTAX EventSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "This variable dictates the urgency of action when a event occurs. There are four severity levels - Critical, Major, Minor, and Informational. Critical events are those, which require immediate operator intervention to prevent/reduce system down time. Major events require quick attention and Minor events possibly require some attention. Informational events indicate the occurrence of events that may need to be investigated." ::= { eventEntry 7 } eventSetTime OBJECT-TYPE SYNTAX UtcTimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This table contains only normal events and this variable represents the time when the event become active, i.e. the number of seconds since Jan 1, 1970 12:00AM." ::= { eventEntry 8 } eventDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable contains a description of the event and reasons behind the event. This is a free format alpha-numeric string that is set by the entity generating this event. This variable may be empty if there is no usefull information to report. The maximum length of this string is 255 characters." ::= { eventEntry 9 } eventServAffective OBJECT-TYPE SYNTAX EventServiceAffective MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates whether the event is service affective or not" ::= { eventEntry 10 } eventInstanceIdNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the InstanceId of a particular event in the event current table. In brief the instanceId refers to the sub-component generating this event in the system, for example '1' for port 1. For more details see the textual conventions section. DEPENDS ON: eventInstanceType" ::= { eventEntry 11 } -- fault Trap MIB faultTrapsMIB MODULE-IDENTITY LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM ORGANIZATION "ZyXEL" CONTACT-INFO "" DESCRIPTION "Fault event trap definitions" ::= { mgs3712 25 } trapInfoObjects OBJECT IDENTIFIER ::= { faultTrapsMIB 1} trapNotifications OBJECT IDENTIFIER ::= { faultTrapsMIB 2} -- ************************************************************************** -- Local Textual Conventions -- ************************************************************************** EventPersistence ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention indicates whether the event is delta (automatically and immediately cleared) or normal (not automatically cleared)." SYNTAX INTEGER{ normal (1), delta (2) } -- ************************************************************************** -- Trap information object definitions -- ************************************************************************** trapRefSeqNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the former sequence number of a cleared event in the event table. Not intended to read but only used in trap notifications." ::= { trapInfoObjects 1 } trapPersistence OBJECT-TYPE SYNTAX EventPersistence MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the event is delta (automatically and immediately cleared) or normal (not automatically cleared). Not intended to read but only used in trap notifications." ::= { trapInfoObjects 2 } trapSenderNodeId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the node ID of the sending network element. If not supported should be set to 0. Not intended to read but only used in trap notifications." ::= { trapInfoObjects 3 } trapSenderStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the trap status. 0 means cleared, 1 means happened." ::= { trapInfoObjects 4 } -- *************************************************************************** -- Trap definitions -- *************************************************************************** eventOnTrap NOTIFICATION-TYPE OBJECTS { eventSeqNum, eventEventId, eventName, eventSetTime, eventSeverity, eventInstanceType, eventInstanceId, eventInstanceName, eventServAffective, eventDescription, eventInstanceIdNumber, trapPersistence, trapSenderNodeId, trapSenderStatus, sysObjectID} STATUS current DESCRIPTION "This trap is used to inform network management system that a delta fault event (events that are automatically cleared) has occured or a normal fault event (not automatically cleared) state has been set on. Objects are used as follows: - eventSeqNum is the sequence number of the event. For normal type of events must equal to the sequence number of the event in the events table. - eventEventId specifies what fault event has occured. - eventName specifies the name of the fault event. - eventSetTime indicates when fault event has occured (delta events) or when fault has been set on (normal events). - eventSeverity reports the severity level of the event. - eventInstanceType indicates what kind of object is faulty. - eventInstanceId specifies what instance is faulty. - eventInstanceName may contain textual description for the faulty object. - eventServAffective specifies whether the event is immediately service affcetive. - eventDescription reports possible additional information about the event. - trapPersistence tells whether this event is a delta or normal event. - trapSenderNodeId specifies the node ID of the sending network element if configuring it is supported for the network element, otherwise 0. - trapSenderStatus specifes the trap status. - sysObjectID specifies what kind of equipment reports the fault event. For more information see the eventTable specification" ::= { trapNotifications 1 } eventClearedTrap NOTIFICATION-TYPE OBJECTS { eventSeqNum, eventEventId, eventSetTime, eventInstanceType, eventInstanceId, eventInstanceIdNumber, trapRefSeqNum, trapSenderNodeId, trapSenderStatus, sysObjectID} STATUS current DESCRIPTION "This trap is used to inform network management system that a normal type fault event has been cleared (state set off). Objects are used as follows: - eventSeqNum is the sequence number of the this clearing event. Note that the sequence number of the cleared event is reported in the trapRefSeqNum object. - eventEventId specifies what event has been cleared. - eventSetTime indicates when fault event has been cleared. - eventInstanceType indicates what kind of object has been faulty. - eventInstanceId specifies what instance has been faulty. - trapRefSeqNum specifies the sequence number of the cleared event (i.e. the sequence number was assigned for the event in the events table). - trapSenderNodeId specifies the node ID of the sending network element if configuring it is supported for the network element, otherwise 0. - sysObjectID specifies what kind of equipment reports the clearing event. For more information see the eventTable specification" ::= { trapNotifications 2 } -- multicastPortSetup multicastPortSetup OBJECT IDENTIFIER ::= { mgs3712 26 } multicastPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MulticastPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { multicastPortSetup 1 } multicastPortEntry OBJECT-TYPE SYNTAX MulticastPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in multicastPortTable." INDEX { dot1dBasePort } ::= { multicastPortTable 1 } MulticastPortEntry ::= SEQUENCE { multicastPortMaxGroupLimited EnabledStatus, multicastPortMaxOfGroup INTEGER, multicastPortIgmpFilteringProfile DisplayString, multicastPortQuerierMode INTEGER, multicastPortThrottlingAction INTEGER, multicastPortLeaveMode INTEGER, multicastPortLeaveTimeout INTEGER, multicastPortFastLeaveTimeout INTEGER } multicastPortMaxGroupLimited OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { multicastPortEntry 2 } multicastPortMaxOfGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0..255" ::= { multicastPortEntry 3 } multicastPortIgmpFilteringProfile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { multicastPortEntry 4 } multicastPortQuerierMode OBJECT-TYPE SYNTAX INTEGER { auto(1), fixed(2), edge(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { multicastPortEntry 5 } multicastPortThrottlingAction OBJECT-TYPE SYNTAX INTEGER { deny(1), replace(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify throttling action for each port" ::= { multicastPortEntry 6 } multicastPortLeaveMode OBJECT-TYPE SYNTAX INTEGER { normal(0), immediate(1), fast(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { multicastPortEntry 7 } multicastPortLeaveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "200..6348800" ::= { multicastPortEntry 8 } multicastPortFastLeaveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "200..6348800" ::= { multicastPortEntry 9 } -- multicastStatus multicastStatus OBJECT IDENTIFIER ::= { mgs3712 27 } multicastStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MulticastStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { multicastStatus 1 } multicastStatusEntry OBJECT-TYPE SYNTAX MulticastStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in multicastStatusTable." INDEX { multicastStatusVlanID, multicastStatusPort, multicastStatusGroup } ::= { multicastStatusTable 1 } MulticastStatusEntry ::= SEQUENCE { multicastStatusIndex INTEGER, multicastStatusVlanID INTEGER, multicastStatusPort INTEGER, multicastStatusGroup IpAddress } multicastStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastStatusEntry 1 } multicastStatusVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastStatusEntry 2 } multicastStatusPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastStatusEntry 3 } multicastStatusGroup OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastStatusEntry 4 } multicastVlanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MulticastVlanStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { multicastStatus 2 } -- multicastVlanStatusTable multicastVlanStatusEntry OBJECT-TYPE SYNTAX MulticastVlanStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in multicastVlanStatusTable." INDEX { multicastVlanStatusVlanID } ::= { multicastVlanStatusTable 1 } MulticastVlanStatusEntry ::= SEQUENCE { multicastVlanStatusVlanID INTEGER, multicastVlanStatusType INTEGER, multicastVlanQueryPort PortList } multicastVlanStatusVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastVlanStatusEntry 1 } multicastVlanStatusType OBJECT-TYPE SYNTAX INTEGER { dynamic(1), mvr (2), static(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastVlanStatusEntry 2 } multicastVlanQueryPort OBJECT-TYPE SYNTAX PortList ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { multicastVlanStatusEntry 3 } -- igmpSnpCountStatus igmpSnpCountStatus OBJECT IDENTIFIER ::= { multicastStatus 3 } -- igmpSnpV2CountTable igmpSnpV2CountQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 1 } igmpSnpV2CountReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 2 } igmpSnpV2CountLeaveRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 3 } igmpSnpV2CountQueryRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 4 } igmpSnpV2CountReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 5 } igmpSnpV2CountLeaveRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 6 } igmpSnpV2CountQueryTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 7 } igmpSnpV2CountReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 8 } igmpSnpV2CountLeaveTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 9 } -- igmpSnpV3CountTable igmpSnpV3CountQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 10 } igmpSnpV3CountReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 11 } igmpSnpV3CountQueryRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 12 } igmpSnpV3CountReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 13 } igmpSnpV3CountQueryTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 14 } igmpSnpV3CountReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpSnpCountStatus 15 } -- igmpSnpCountVlanStatus igmpSnpCountVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpSnpCountVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { multicastStatus 4} igmpSnpCountVlanEntry OBJECT-TYPE SYNTAX IgmpSnpCountVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in igmpGroupVlanStatus." INDEX { igmpSnpCountVlanIndex } ::= { igmpSnpCountVlanTable 1 } IgmpSnpCountVlanEntry ::= SEQUENCE { igmpSnpCountVlanIndex INTEGER, igmpSnpV2CountVlanQueryRx INTEGER, igmpSnpV2CountVlanReportRx INTEGER, igmpSnpV2CountVlanLeaveRx INTEGER, igmpSnpV2CountVlanQueryRxDrop INTEGER, igmpSnpV2CountVlanReportRxDrop INTEGER, igmpSnpV2CountVlanLeaveRxDrop INTEGER, igmpSnpV2CountVlanQueryTx INTEGER, igmpSnpV2CountVlanReportTx INTEGER, igmpSnpV2CountVlanLeaveTx INTEGER, igmpSnpV3CountVlanQueryRx INTEGER, igmpSnpV3CountVlanReportRx INTEGER, igmpSnpV3CountVlanQueryRxDrop INTEGER, igmpSnpV3CountVlanReportRxDrop INTEGER, igmpSnpV3CountVlanQueryTx INTEGER, igmpSnpV3CountVlanReportTx INTEGER } igmpSnpCountVlanIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Input vlan" ::={ igmpSnpCountVlanEntry 1} igmpSnpV2CountVlanQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx counters for vlan" ::={ igmpSnpCountVlanEntry 2} igmpSnpV2CountVlanReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx counters for vlan" ::={ igmpSnpCountVlanEntry 3} igmpSnpV2CountVlanLeaveRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Rx counters for vlan" ::={ igmpSnpCountVlanEntry 4} igmpSnpV2CountVlanQueryRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx Error counters for vlan" ::={ igmpSnpCountVlanEntry 5} igmpSnpV2CountVlanReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx Error counters for vlan" ::={ igmpSnpCountVlanEntry 6} igmpSnpV2CountVlanLeaveRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Rx Error counters for vlan" ::={ igmpSnpCountVlanEntry 7} igmpSnpV2CountVlanQueryTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Tx counters for vlan" ::={ igmpSnpCountVlanEntry 8} igmpSnpV2CountVlanReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Tx counters for vlan" ::={ igmpSnpCountVlanEntry 9} igmpSnpV2CountVlanLeaveTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Tx counters for vlan" ::={ igmpSnpCountVlanEntry 10} igmpSnpV3CountVlanQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx counters for vlan" ::={ igmpSnpCountVlanEntry 11} igmpSnpV3CountVlanReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx counters for vlan" ::={ igmpSnpCountVlanEntry 12} igmpSnpV3CountVlanQueryRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx Error counters for vlan" ::={ igmpSnpCountVlanEntry 13} igmpSnpV3CountVlanReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx Error counters for vlan" ::={ igmpSnpCountVlanEntry 14} igmpSnpV3CountVlanQueryTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Tx counters for vlan" ::={ igmpSnpCountVlanEntry 15} igmpSnpV3CountVlanReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Tx counters for vlan" ::={ igmpSnpCountVlanEntry 16} --igmpSnpCountPortStatus igmpSnpCountPortTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpSnpCountPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { multicastStatus 5} igmpSnpCountPortEntry OBJECT-TYPE SYNTAX IgmpSnpCountPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in igmpSnpCountPortStatus." INDEX { dot1dBasePort } ::= { igmpSnpCountPortTable 1 } IgmpSnpCountPortEntry ::= SEQUENCE { igmpSnpV2CountPortQueryRx INTEGER, igmpSnpV2CountPortReportRx INTEGER, igmpSnpV2CountPortLeaveRx INTEGER, igmpSnpV2CountPortReportRxDrop INTEGER, igmpSnpV2CountPortLeaveRxDrop INTEGER, igmpSnpV2CountPortReportTx INTEGER, igmpSnpV2CountPortLeaveTx INTEGER, igmpSnpV3CountPortQueryRx INTEGER, igmpSnpV3CountPortReportRx INTEGER, igmpSnpV3CountPortReportRxDrop INTEGER, igmpSnpV3CountPortReportTx INTEGER } igmpSnpV2CountPortQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx counters for port" ::={ igmpSnpCountPortEntry 1} igmpSnpV2CountPortReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx counters for port" ::={ igmpSnpCountPortEntry 2} igmpSnpV2CountPortLeaveRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Rx counters for port" ::={ igmpSnpCountPortEntry 3} igmpSnpV2CountPortReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx Error counters for port" ::={ igmpSnpCountPortEntry 4} igmpSnpV2CountPortLeaveRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Rx Error counters for port" ::={ igmpSnpCountPortEntry 5} igmpSnpV2CountPortReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Tx counters for port" ::={ igmpSnpCountPortEntry 6} igmpSnpV2CountPortLeaveTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Leave Tx counters for port" ::={ igmpSnpCountPortEntry 7} igmpSnpV3CountPortQueryRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Query Rx counters for port" ::={ igmpSnpCountPortEntry 8} igmpSnpV3CountPortReportRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx counters for port" ::={ igmpSnpCountPortEntry 9} igmpSnpV3CountPortReportRxDrop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Rx Error counters for port" ::={ igmpSnpCountPortEntry 10} igmpSnpV3CountPortReportTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "show igmpsnp Report Tx counters for port" ::={ igmpSnpCountPortEntry 11} -- igmpSnpGroupCountStatus igmpSnpGroupCountStatus OBJECT IDENTIFIER ::= { multicastStatus 6 } igmpSnpGroupCountNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Show total IGMP snooping group number" ::= { igmpSnpGroupCountStatus 1 } -- igmpGroupCountVlanTable igmpSnpGroupCountVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpSnpGroupCountVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { igmpSnpGroupCountStatus 2} igmpSnpGroupCountVlanEntry OBJECT-TYPE SYNTAX IgmpSnpGroupCountVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in igmpSnpGroupVlanStatus." INDEX { igmpSnpGroupCountVlanIndex } ::= { igmpSnpGroupCountVlanTable 1 } IgmpSnpGroupCountVlanEntry ::= SEQUENCE { igmpSnpGroupCountVlanIndex INTEGER, igmpSnpGroupCountVlanNum INTEGER } igmpSnpGroupCountVlanIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Show IGMP snooping group index for vlan" ::= { igmpSnpGroupCountVlanEntry 1} igmpSnpGroupCountVlanNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Show IGMP snooping group number for vlan" ::={ igmpSnpGroupCountVlanEntry 2} -- igmpGroupCountPortTable igmpSnpGroupCountPortTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpSnpGroupCountPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= {igmpSnpGroupCountStatus 3} igmpSnpGroupCountPortEntry OBJECT-TYPE SYNTAX IgmpSnpGroupCountPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in igmpGroupCountPortStatus." INDEX { dot1dBasePort } ::= { igmpSnpGroupCountPortTable 1 } IgmpSnpGroupCountPortEntry ::= SEQUENCE { igmpSnpGroupCountPortNum INTEGER } igmpSnpGroupCountPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Show IGMP snooping group number for port" ::={ igmpSnpGroupCountPortEntry 1} -- igmpFilteringProfileSetup igmpFilteringProfileSetup OBJECT IDENTIFIER ::= { mgs3712 28 } igmpFilteringMaxNumberOfProfile OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileSetup 1 } igmpFilteringProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF IgmpFilteringProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileSetup 2 } igmpFilteringProfileEntry OBJECT-TYPE SYNTAX IgmpFilteringProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in igmpFilteringProfileTable." INDEX { igmpFilteringProfileName, igmpFilteringProfileStartAddress, igmpFilteringProfileEndAddress } ::= { igmpFilteringProfileTable 1 } IgmpFilteringProfileEntry ::= SEQUENCE { igmpFilteringProfileName DisplayString, igmpFilteringProfileStartAddress IpAddress, igmpFilteringProfileEndAddress IpAddress, igmpFilteringProfileRowStatus RowStatus } igmpFilteringProfileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileEntry 1 } igmpFilteringProfileStartAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileEntry 2 } igmpFilteringProfileEndAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileEntry 3 } igmpFilteringProfileRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { igmpFilteringProfileEntry 4 } -- MVRSetup mvrSetup OBJECT IDENTIFIER ::= { mgs3712 29 } maxNumberOfMVR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mvrSetup 1 } mvrTable OBJECT-TYPE SYNTAX SEQUENCE OF MvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { mvrSetup 2 } mvrEntry OBJECT-TYPE SYNTAX MvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in mvrTable." INDEX { mvrVlanID } ::= { mvrTable 1 } MvrEntry ::= SEQUENCE { mvrVlanID INTEGER, mvrName DisplayString, mvrMode INTEGER, mvrRowStatus RowStatus, mvr8021pPriority INTEGER } mvrVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1..4094" ::= { mvrEntry 1 } mvrName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrEntry 2 } mvrMode OBJECT-TYPE SYNTAX INTEGER { dynamic(0), compatible(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrEntry 3 } mvrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { mvrEntry 4 } mvr8021pPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set the 802.1p priority of control messages within MVR (0~7)" ::= { mvrEntry 5 } mvrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MvrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { mvrSetup 3 } mvrPortEntry OBJECT-TYPE SYNTAX MvrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in mvrPortTable." INDEX { mvrVlanID, dot1dBasePort } ::= { mvrPortTable 1 } MvrPortEntry ::= SEQUENCE { mvrPortRole INTEGER, mvrPortTagging EnabledStatus } mvrPortRole OBJECT-TYPE SYNTAX INTEGER { none(1), source_port(2), receiver_port(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrPortEntry 1 } mvrPortTagging OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrPortEntry 2 } maxNumberOfMvrGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mvrSetup 4 } mvrGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF MvrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { mvrSetup 5 } mvrGroupEntry OBJECT-TYPE SYNTAX MvrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in mvrGroupTable." INDEX { mvrVlanID, mvrGroupName } ::= { mvrGroupTable 1 } MvrGroupEntry ::= SEQUENCE { mvrGroupName DisplayString, mvrGroupStartAddress IpAddress, mvrGroupEndAddress IpAddress, mvrGroupRowStatus RowStatus } mvrGroupName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mvrGroupEntry 1 } mvrGroupStartAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrGroupEntry 2 } mvrGroupEndAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mvrGroupEntry 3 } mvrGroupRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { mvrGroupEntry 4 } -- clusterSetup clusterSetup OBJECT IDENTIFIER ::= { mgs3712 30 } -- clusterManager clusterManager OBJECT IDENTIFIER ::= { clusterSetup 1 } clusterMaxNumOfManager OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterManager 1 } -- clusterManagerTable clusterManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF ClusterManagerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { clusterManager 2 } clusterManagerEntry OBJECT-TYPE SYNTAX ClusterManagerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in clusterManagerTable." INDEX { clusterManagerVid } ::= { clusterManagerTable 1 } ClusterManagerEntry ::= SEQUENCE { clusterManagerVid INTEGER, clusterManagerName DisplayString, clusterManagerRowStatus RowStatus } clusterManagerVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterManagerEntry 1 } clusterManagerName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { clusterManagerEntry 2 } clusterManagerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { clusterManagerEntry 3 } -- clusterMembers clusterMembers OBJECT IDENTIFIER ::= { clusterSetup 2 } clusterMaxNumOfMember OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterMembers 1 } -- clusterMemberTable clusterMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF ClusterMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { clusterMembers 2 } clusterMemberEntry OBJECT-TYPE SYNTAX ClusterMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in clusterMemberTable." INDEX { clusterMemberMac } ::= { clusterMemberTable 1 } ClusterMemberEntry ::= SEQUENCE { clusterMemberMac MacAddress, clusterMemberName DisplayString, clusterMemberModel DisplayString, clusterMemberPassword DisplayString, clusterMemberRowStatus RowStatus } clusterMemberMac OBJECT-TYPE SYNTAX MacAddress ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { clusterMemberEntry 1 } clusterMemberName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterMemberEntry 2 } clusterMemberModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterMemberEntry 3 } clusterMemberPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { clusterMemberEntry 4 } clusterMemberRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { clusterMemberEntry 5 } -- clusterCandidates clusterCandidates OBJECT IDENTIFIER ::= { clusterSetup 3 } -- clusterCandidateTable clusterCandidateTable OBJECT-TYPE SYNTAX SEQUENCE OF ClusterCandidateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { clusterCandidates 1 } clusterCandidateEntry OBJECT-TYPE SYNTAX ClusterCandidateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in clusterCandidateTable." INDEX { clusterCandidateMac } ::= { clusterCandidateTable 1 } ClusterCandidateEntry ::= SEQUENCE { clusterCandidateMac MacAddress, clusterCandidateName DisplayString, clusterCandidateModel DisplayString } clusterCandidateMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterCandidateEntry 1 } clusterCandidateName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterCandidateEntry 2 } clusterCandidateModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterCandidateEntry 3 } -- clusterStatus clusterStatus OBJECT IDENTIFIER ::= { clusterSetup 4 } clusterStatusRole OBJECT-TYPE SYNTAX INTEGER { none(0), manager(1), member(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatus 1 } clusterStatusManager OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatus 2 } clsuterStatusNumOfMember OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatus 3 } -- clusterStatusMemberTable clusterStatusMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF ClusterStatusMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { clusterStatus 4 } clusterStatusMemberEntry OBJECT-TYPE SYNTAX ClusterStatusMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in clusterStatusMemberTable." INDEX { clusterStatusMemberMac } ::= { clusterStatusMemberTable 1 } ClusterStatusMemberEntry ::= SEQUENCE { clusterStatusMemberMac MacAddress, clusterStatusMemberName DisplayString, clusterStatusMemberModel DisplayString, clusterStatusMemberStatus INTEGER } clusterStatusMemberMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatusMemberEntry 1 } clusterStatusMemberName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatusMemberEntry 2 } clusterStatusMemberModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatusMemberEntry 3 } clusterStatusMemberStatus OBJECT-TYPE SYNTAX INTEGER { error(0), online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { clusterStatusMemberEntry 4 } -- sysLogSetup sysLogSetup OBJECT IDENTIFIER ::= { mgs3712 31 } sysLogState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "sysLog enabled/disabled for the switch." ::= { sysLogSetup 1 } -- sysLogTypeTable sysLogTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF SysLogTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sysLogSetup 2 } sysLogTypeEntry OBJECT-TYPE SYNTAX SysLogTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in sysLogTypeTable." INDEX { sysLogTypeIndex } ::= { sysLogTypeTable 1 } SysLogTypeEntry ::= SEQUENCE { sysLogTypeIndex INTEGER, sysLogTypeName DisplayString, sysLogTypeState EnabledStatus, sysLogTypeFacility INTEGER } sysLogTypeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sysLogTypeEntry 1 } sysLogTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sysLogTypeEntry 2 } sysLogTypeState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sysLogTypeEntry 3 } sysLogTypeFacility OBJECT-TYPE SYNTAX INTEGER { local_user0(0), local_user1(1), local_user2(2), local_user3(3), local_user4(4), local_user5(5), local_user6(6), local_user7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sysLogTypeEntry 4 } -- sysLogServerTable sysLogServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SysLogServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sysLogSetup 3 } sysLogServerEntry OBJECT-TYPE SYNTAX SysLogServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in sysLogServerTable." INDEX { sysLogServerAddress } ::= { sysLogServerTable 1 } SysLogServerEntry ::= SEQUENCE { sysLogServerAddress IpAddress, sysLogServerLogLevel INTEGER, sysLogServerRowStatus RowStatus } sysLogServerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sysLogServerEntry 1 } sysLogServerLogLevel OBJECT-TYPE SYNTAX INTEGER { level0(0), level0-1(1), level0-2(2), level0-3(3), level0-4(4), level0-5(5), level0-6(6), level0-7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sysLogServerEntry 2 } sysLogServerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { sysLogServerEntry 3 } -- MRSTP mrstp OBJECT IDENTIFIER ::= { mgs3712 32 } mrstpSetup OBJECT IDENTIFIER ::= { mrstp 1 } mrstpBridgeTable OBJECT-TYPE SYNTAX SEQUENCE OF MrstpBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { mrstpSetup 1 } mrstpBridgeEntry OBJECT-TYPE SYNTAX MrstpBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in mrstpBridgeTable." INDEX { mrstpBridgeIndex } ::= { mrstpBridgeTable 1 } MrstpBridgeEntry ::= SEQUENCE { mrstpBridgeIndex INTEGER, mrstpState INTEGER, mrstpProtocolSpecification INTEGER, mrstpPriority INTEGER, mrstpTimeSinceTopologyChange TimeTicks, mrstpTopChanges Counter, mrstpDesignatedRoot BridgeId, mrstpRootCost INTEGER, mrstpRootPort INTEGER, mrstpMaxAge Timeout, mrstpHelloTime Timeout, mrstpHoldTime INTEGER, mrstpForwardDelay Timeout, mrstpBridgeMaxAge Timeout, mrstpBridgeHelloTime Timeout, mrstpBridgeForwardDelay Timeout } -- the dot1dStp group -- Implementation of the dot1dStp group is optional. It is -- implemented by those bridges that support the Spanning Tree -- Protocol. mrstpBridgeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The tree index of the MRSTP." ::= { mrstpBridgeEntry 1 } mrstpState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled on the mrstp bridge." ::= { mrstpBridgeEntry 2 } mrstpProtocolSpecification OBJECT-TYPE SYNTAX INTEGER { unknown(1), decLb100(2), ieee8021d(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined." ::= { mrstpBridgeEntry 3 } mrstpPriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the write-able portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of dot1dBaseBridgeAddress." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.7" ::= { mrstpBridgeEntry 4 } mrstpTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity." REFERENCE "IEEE 802.1D-1990: Section 6.8.1.1.3" ::= { mrstpBridgeEntry 5 } mrstpTopChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of topology changes detected by this bridge since the management entity was last reset or initialized." REFERENCE "IEEE 802.1D-1990: Section 6.8.1.1.3" ::= { mrstpBridgeEntry 6 } mrstpDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.1" ::= { mrstpBridgeEntry 7 } mrstpRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cost of the path to the root as seen from this bridge." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.2" ::= { mrstpBridgeEntry 8 } mrstpRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the port which offers the lowest cost path from this bridge to the root bridge." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.3" ::= { mrstpBridgeEntry 9 } mrstpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.4" ::= { mrstpBridgeEntry 10 } mrstpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.5" ::= { mrstpBridgeEntry 11 } mrstpHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.14" ::= { mrstpBridgeEntry 12 } mrstpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to mrstpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]" REFERENCE "IEEE 802.1D-1990: Section 4.5.3.6" ::= { mrstpBridgeEntry 13 } mrstpBridgeMaxAge OBJECT-TYPE SYNTAX Timeout (600..4000) ACCESS read-write STATUS mandatory DESCRIPTION "The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of mrstpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.8" ::= { mrstpBridgeEntry 14 } mrstpBridgeHelloTime OBJECT-TYPE SYNTAX Timeout (100..1000) ACCESS read-write STATUS mandatory DESCRIPTION "The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.9" ::= { mrstpBridgeEntry 15 } mrstpBridgeForwardDelay OBJECT-TYPE SYNTAX Timeout (400..3000) ACCESS read-write STATUS mandatory DESCRIPTION "The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of mrstpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.10" ::= { mrstpBridgeEntry 16 } -- The Spanning Tree Port Table mrstpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MrstpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains port-specific information for the Spanning Tree Protocol." ::= { mrstpSetup 2 } mrstpPortEntry OBJECT-TYPE SYNTAX MrstpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information maintained by every port about the Spanning Tree Protocol state for that port." INDEX { mrstpPort } ::= { mrstpPortTable 1 } MrstpPortEntry ::= SEQUENCE { mrstpPort INTEGER, mrstpPortPriority INTEGER, mrstpPortState INTEGER, mrstpPortEnable INTEGER, mrstpPortPathCost INTEGER, mrstpPortDesignatedRoot BridgeId, mrstpPortDesignatedCost INTEGER, mrstpPortDesignatedBridge BridgeId, mrstpPortDesignatedPort OCTET STRING, mrstpPortForwardTransitions Counter, mrstpPortOnBridgeIndex INTEGER } mrstpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the port for which this entry contains Spanning Tree Protocol management information." REFERENCE "IEEE 802.1D-1990: Section 6.8.2.1.2" ::= { mrstpPortEntry 1 } mrstpPortPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of mrstpPort." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.1" ::= { mrstpPortEntry 2 } mrstpPortState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see mrstpPortEnable), this object will have a value of disabled(1)." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.2" ::= { mrstpPortEntry 3 } mrstpPortEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled status of the port." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.2" ::= { mrstpPortEntry 4 } mrstpPortPathCost OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.3" ::= { mrstpPortEntry 5 } mrstpPortDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.4" ::= { mrstpPortEntry 6 } mrstpPortDesignatedCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.5" ::= { mrstpPortEntry 7 } mrstpPortDesignatedBridge OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.6" ::= { mrstpPortEntry 8 } mrstpPortDesignatedPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "The Port Identifier of the port on the Designated Bridge for this port's segment." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.7" ::= { mrstpPortEntry 9 } mrstpPortForwardTransitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this port has transitioned from the Learning state to the Forwarding state." ::= { mrstpPortEntry 10 } mrstpPortOnBridgeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indetify the bridge index that this port joined to in MRSTP." ::= { mrstpPortEntry 11 } -- MRSTP Trap mrstpNotifications OBJECT IDENTIFIER ::= { mrstp 2 } newRoot NOTIFICATION-TYPE OBJECTS { mrstpBridgeIndex } STATUS current DESCRIPTION "" ::= { mrstpNotifications 1 } topologyChange NOTIFICATION-TYPE OBJECTS { mrstpBridgeIndex } STATUS current DESCRIPTION "" ::= { mrstpNotifications 2 } -- classifierSetup classifierSetup OBJECT IDENTIFIER ::= { mgs3712 33 } classifierRuleTable OBJECT-TYPE SYNTAX SEQUENCE OF ClassifierRuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { classifierSetup 1 } classifierRuleEntry OBJECT-TYPE SYNTAX ClassifierRuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in classifierRuleTable." INDEX {classifierName } ::= { classifierRuleTable 1 } ClassifierRuleEntry ::= SEQUENCE { classifierName DisplayString, classifierEnable INTEGER, classifierPacketFormat INTEGER, classifierVlanId INTEGER, classifier8021pPriority INTEGER, classifierEtherType INTEGER, classifierSrcMAC MacAddress, classifierIncomingPort INTEGER, classifierDstMAC MacAddress, classifierDSCP INTEGER, classifierIpProtocol INTEGER, classifierEstablishOnly INTEGER, classifierSrcIp IpAddress, classifierSrcIpMask INTEGER, classifierSrcSocket INTEGER, classifierDstIp IpAddress, classifierDstIpMask INTEGER, classifierDstSocket INTEGER, classifierRowstatus RowStatus } classifierName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Name of classifier rule." ::= { classifierRuleEntry 1 } classifierEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-only STATUS mandatory DESCRIPTION "Classifier rule enabled/disabled." ::= { classifierRuleEntry 2 } classifierPacketFormat OBJECT-TYPE SYNTAX INTEGER { all(1), ethernetII-untagged(2), ethernetII-tagged(3), ethernet802_3-untagged(4), ethernet802_3-tagged(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Packet format for classifier rule. All(1), 802.3 untagged(2), 802.3 tagged(3), EthernetII untagged(4), EthernetII tagged(5)." ::= { classifierRuleEntry 3 } classifierVlanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Vlan id for classifer rule, 1~4094. Value 0 means any" ::= { classifierRuleEntry 4 } classifier8021pPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "802.1p priority for classifier rule, 0~7. Value -1 means any" ::= { classifierRuleEntry 5 } classifierEtherType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Ether type for classifier rule, in decimal expression. Value 65535 means any" ::= { classifierRuleEntry 6 } classifierSrcMAC OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "Source mac address for classifier rule. 00:00:00:00:00:00 means any" ::= { classifierRuleEntry 7 } classifierIncomingPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Incoming Port for classifier rule. Value 65536 means any" ::= { classifierRuleEntry 8 } classifierDstMAC OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "Destination mac address for classifier rule. 00:00:00:00:00:00 means any" ::= { classifierRuleEntry 9 } classifierDSCP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DSCP for classifier rule. Value -1 means any" ::= { classifierRuleEntry 10 } classifierIpProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "IP Protocol for classifier rule. Value 255 means any" ::= { classifierRuleEntry 11 } classifierEstablishOnly OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-only STATUS mandatory DESCRIPTION "IP Protocol for EstablishOnly in classifier rule" ::= { classifierRuleEntry 12 } classifierSrcIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Source IP address for classifier rule. 0.0.0.0 means any" ::= { classifierRuleEntry 13 } classifierSrcIpMask OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Source IP Mask for classifier rule." ::= { classifierRuleEntry 14 } classifierSrcSocket OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Source Socket Number for classifier rule. Value 0 means any" ::= { classifierRuleEntry 15 } classifierDstIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Destination IP address for classifier rule. 0.0.0.0 means any" ::= { classifierRuleEntry 16 } classifierDstIpMask OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Destination IP Mask for classifier rule" ::= { classifierRuleEntry 17 } classifierDstSocket OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Destination Socket Number for classifier rule. Value 0 means any" ::= { classifierRuleEntry 18 } classifierRowstatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "Row Status for classifier rule" ::= { classifierRuleEntry 19 } -- policySetup policySetup OBJECT IDENTIFIER ::= { mgs3712 34 } policyTable OBJECT-TYPE SYNTAX SEQUENCE OF PolicyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { policySetup 1 } policyEntry OBJECT-TYPE SYNTAX PolicyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in policyTable." INDEX {policyName } ::= { policyTable 1 } PolicyEntry ::= SEQUENCE { policyName DisplayString, policyEnable INTEGER, policyClassifier DisplayString, policyEgressPort INTEGER, policy8021pPriority INTEGER, policyDSCP INTEGER, policyTOS INTEGER, policyBandwidth INTEGER, policyOutOfProfileDSCP INTEGER, policyForwardingAction INTEGER, policyPriorityAction INTEGER, policyDiffServAction INTEGER, policyOutgoingAction BITS, policyMeteringEnable INTEGER, policyOutOfProfileAction BITS, policyRowstatus RowStatus } policyName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Name of policy rule." ::= { policyEntry 1 } policyEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-only STATUS mandatory DESCRIPTION "Policy rule enabled/disabled." ::= { policyEntry 2 } policyClassifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Classifier of policy rule." ::= { policyEntry 3 } policyEgressPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Egress Port for policy rule" ::= { policyEntry 5 } policy8021pPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "802.1p priority for policy rule, 0~7." ::= { policyEntry 7 } policyDSCP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DSCP for policy rule." ::= { policyEntry 8 } policyTOS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TOS for policy rule, 0~7" ::= { policyEntry 9 } policyBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bandwidth for policy rule" ::= { policyEntry 10 } policyOutOfProfileDSCP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Out Of Profile DSCP for policy rule." ::= { policyEntry 11 } policyForwardingAction OBJECT-TYPE SYNTAX INTEGER { no-change(1), discard-the-packet(2), do-not-drop-the-matching-frame-previously-marked-for-dopping(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Forwarding Action for policy rule" ::= { policyEntry 12 } policyPriorityAction OBJECT-TYPE SYNTAX INTEGER { no-change(1), set-the-packets-802_1-priority(2), send-the-packet-to-priority-queue(3), replace-the-802_1-priority-field-with-the-IP-TOS-value(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Priority Action for policy rule" ::= { policyEntry 13} policyDiffServAction OBJECT-TYPE SYNTAX INTEGER { no-change(1), set-the-packets-TOS-field(2), replace-the-IP-TOS-field-with-the-802_1-priority-value(3), set-the-Diffserv-Codepoint-field-in-the-frame(4) } ACCESS read-only STATUS mandatory DESCRIPTION "DiffServ Action for policy rule" ::= { policyEntry 14} policyOutgoingAction OBJECT-TYPE SYNTAX BITS { send-the-packet-to-the-mirror-port(0), send-the-packet-to-the-egress-port(1), send-the-matching-frames-to-the-egress-port(2), set-the-packets-VLAN-ID(3) } ACCESS read-create STATUS current DESCRIPTION "Outgoing Action for policy rule. Started bit is from MSB bit7 (bit7~bit0). " ::= { policyEntry 15 } policyMeteringEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Metering for Policy rule enabled/disabled." ::= { policyEntry 16 } policyOutOfProfileAction OBJECT-TYPE SYNTAX BITS { drop-the-packet(0), change-the-DSCP-value(1), set-Out-Drop-Precedence(2), do-not-drop-the-matching-frame-previously-marked-for-dropping(3) } ACCESS read-create STATUS current DESCRIPTION "Out Of Profile Action for policy rule. Started bit is from MSB bit7 (bit7~bit0)." ::= { policyEntry 17 } policyRowstatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "Row Status for policy rule" ::= { policyEntry 18 } -- radiusServerSetup radiusServerSetup OBJECT IDENTIFIER ::= { mgs3712 35 } radiusAuthServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 1 } radiusAuthServerMode OBJECT-TYPE SYNTAX INTEGER{ index-priority(1), round-robin(2), } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerSetup 1 } radiusAuthServerTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerSetup 2 } -- radiusAuthServerTable radiusAuthServerTable OBJECT-TYPE SYNTAX SEQUENCE OF RadiusAuthServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerSetup 3 } radiusAuthServerEntry OBJECT-TYPE SYNTAX RadiusAuthServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in radiusAuthServerTable." INDEX { radiusAuthServerIndex } ::= { radiusAuthServerTable 1 } RadiusAuthServerEntry ::= SEQUENCE { radiusAuthServerIndex INTEGER, radiusAuthServerIpAddr IpAddress, radiusAuthServerUdpPort INTEGER, radiusAuthServerSharedSecret DisplayString } radiusAuthServerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerEntry 1 } radiusAuthServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerEntry 2 } radiusAuthServerUdpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerEntry 3 } radiusAuthServerSharedSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAuthServerEntry 4 } radiusAcctServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 2 } radiusAcctServerTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerSetup 1 } -- radiusAcctServerTable radiusAcctServerTable OBJECT-TYPE SYNTAX SEQUENCE OF RadiusAcctServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerSetup 2 } radiusAcctServerEntry OBJECT-TYPE SYNTAX RadiusAcctServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in radiusAcctServerTable." INDEX { radiusAcctServerIndex } ::= { radiusAcctServerTable 1 } RadiusAcctServerEntry ::= SEQUENCE { radiusAcctServerIndex INTEGER, radiusAcctServerIpAddr IpAddress, radiusAcctServerUdpPort INTEGER, radiusAcctServerSharedSecret DisplayString } radiusAcctServerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerEntry 1 } radiusAcctServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerEntry 2 } radiusAcctServerUdpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerEntry 3 } radiusAcctServerSharedSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { radiusAcctServerEntry 4 } -- tacacsServerSetup tacacsServerSetup OBJECT IDENTIFIER ::= { mgs3712 36 } tacacsAuthServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 1 } tacacsAuthServerMode OBJECT-TYPE SYNTAX INTEGER{ index-priority(1), round-robin(2), } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerSetup 1 } tacacsAuthServerTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerSetup 2 } -- tacacsAuthServerTable tacacsAuthServerTable OBJECT-TYPE SYNTAX SEQUENCE OF TacacsAuthServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerSetup 3 } tacacsAuthServerEntry OBJECT-TYPE SYNTAX TacacsAuthServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in tacacsAuthServerTable." INDEX { tacacsAuthServerIndex } ::= { tacacsAuthServerTable 1 } TacacsAuthServerEntry ::= SEQUENCE { tacacsAuthServerIndex INTEGER, tacacsAuthServerIpAddr IpAddress, tacacsAuthServerTcpPort INTEGER, tacacsAuthServerSharedSecret DisplayString } tacacsAuthServerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerEntry 1 } tacacsAuthServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerEntry 2 } tacacsAuthServerTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerEntry 3 } tacacsAuthServerSharedSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAuthServerEntry 4 } tacacsAcctServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 2 } tacacsAcctServerTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerSetup 1 } -- tacacsAcctServerTable tacacsAcctServerTable OBJECT-TYPE SYNTAX SEQUENCE OF TacacsAcctServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerSetup 2 } tacacsAcctServerEntry OBJECT-TYPE SYNTAX TacacsAcctServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in tacacsAcctServerTable." INDEX { tacacsAcctServerIndex } ::= { tacacsAcctServerTable 1 } TacacsAcctServerEntry ::= SEQUENCE { tacacsAcctServerIndex INTEGER, tacacsAcctServerIpAddr IpAddress, tacacsAcctServerTcpPort INTEGER, tacacsAcctServerSharedSecret DisplayString } tacacsAcctServerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerEntry 1 } tacacsAcctServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerEntry 2 } tacacsAcctServerTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerEntry 3 } tacacsAcctServerSharedSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { tacacsAcctServerEntry 4 } -- aaaSetup aaaSetup OBJECT IDENTIFIER ::= { mgs3712 37 } authenticationSetup OBJECT IDENTIFIER ::= { aaaSetup 1 } -- authenticationTypeTable authenticationTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF AuthenticationTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { authenticationSetup 1 } authenticationTypeEntry OBJECT-TYPE SYNTAX AuthenticationTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in authenticationTypeTable." INDEX { authenticationTypeName } ::= { authenticationTypeTable 1 } AuthenticationTypeEntry ::= SEQUENCE { authenticationTypeName DisplayString, authenticationTypeMethodList OCTET STRING } authenticationTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { authenticationTypeEntry 1 } authenticationTypeMethodList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { authenticationTypeEntry 2 } accountingSetup OBJECT IDENTIFIER ::= { aaaSetup 2 } accountingUpdatePeriod OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingSetup 1 } -- accountingTypeTable accountingTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF AccountingTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { accountingSetup 2 } accountingTypeEntry OBJECT-TYPE SYNTAX AccountingTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in accountingTypeTable." INDEX { accountingTypeName } ::= { accountingTypeTable 1 } AccountingTypeEntry ::= SEQUENCE { accountingTypeName DisplayString, accountingTypeActive EnabledStatus, accountingTypeBroadcast EnabledStatus, accountingTypeMode INTEGER, accountingTypeMethod INTEGER, accountingTypePrivilege INTEGER } accountingTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 1 } accountingTypeActive OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 2 } accountingTypeBroadcast OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 3 } accountingTypeMode OBJECT-TYPE SYNTAX INTEGER{ not-available(255), start-stop(1), stop-only(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 4 } accountingTypeMethod OBJECT-TYPE SYNTAX INTEGER{ radius(1), tacacs(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 5 } accountingTypePrivilege OBJECT-TYPE SYNTAX INTEGER{ not-available(255), privilege-0(0), privilege-1(1), privilege-2(2), privilege-3(3), privilege-4(4), privilege-5(5), privilege-6(6), privilege-7(7), privilege-8(8), privilege-9(9), privilege-10(10), privilege-11(11), privilege-12(12), privilege-13(13), privilege-14(14) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { accountingTypeEntry 6 } authorizationSetup OBJECT IDENTIFIER ::= { aaaSetup 3 } -- authorizationTypeTable authorizationTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF AuthorizationTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { authorizationSetup 1 } authorizationTypeEntry OBJECT-TYPE SYNTAX AuthorizationTypeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in authorizationTypeTable." INDEX { authorizationTypeName } ::= { authorizationTypeTable 1 } AuthorizationTypeEntry ::= SEQUENCE { authorizationTypeName DisplayString, authorizationTypeActive EnabledStatus, authorizationTypeMethod INTEGER } authorizationTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { authorizationTypeEntry 1 } authorizationTypeActive OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { authorizationTypeEntry 2 } authorizationTypeMethod OBJECT-TYPE SYNTAX INTEGER{ radius(1), tacacs(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { authorizationTypeEntry 3 } --------------------------------------------------- -- -- vlan stacking -- --------------------------------------------------- -- vlanStackSetup vlanStackSetup OBJECT IDENTIFIER ::= { mgs3712 38 } vlanStackState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Stacking enabled/disabled for the switch." ::= { vlanStackSetup 1 } -- vlanStackTpid OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "SP TPID in hex format, e.g. 8100." -- ::= { vlanStackSetup 2 } -- vlanStackPortTable vlanStackPortTable OBJECT-TYPE SYNTAX SEQUENCE OF VlanStackPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { vlanStackSetup 3 } vlanStackPortEntry OBJECT-TYPE SYNTAX VlanStackPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in vlanStackPortTable." INDEX { dot1dBasePort } ::= { vlanStackPortTable 1 } VlanStackPortEntry ::= SEQUENCE { vlanStackPortMode INTEGER, vlanStackPortVid INTEGER, vlanStackPortPrio INTEGER, vlanStackTunnelPortTpid INTEGER } vlanStackPortMode OBJECT-TYPE SYNTAX INTEGER { normal(1), access(2), tunnel(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the port. Set Normal to have the switch ignore frames received (or transmitted) on this port with VLAN stacking tags. Anything you configure in SPVID and Priority are ignored. Set Access mode to have the switch add the SP TPID tag to all incoming frames received on this port. Set Access mode for ingress ports at the edge of the service provider's network. Set Tunnel mode (available for Gigabit ports only) for egress ports at the edge of the service provider's network. In order to support VLAN stacking on a port, the port must be able to allow frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag) to pass through it. normal (1), Access (2), tunnel (3)" ::= { vlanStackPortEntry 1 } vlanStackPortVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "VLAN ID used in service provider tag." ::= { vlanStackPortEntry 2 } vlanStackPortPrio OBJECT-TYPE SYNTAX INTEGER { prioriry-0(0), prioriry-1(1), prioriry-2(2), prioriry-3(3), prioriry-4(4), prioriry-5(5), prioriry-6(6), prioriry-7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Priority value for service provider tag. 0 is the lowest priority level and 7 is the highest." ::= { vlanStackPortEntry 3 } vlanStackTunnelPortTpid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tunnel Port TPID in hex format, e.g. 8100." ::= { vlanStackPortEntry 4 } -- selectiveQinQTable selectiveQinQTable OBJECT-TYPE SYNTAX SEQUENCE OF SelectiveQinQEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { vlanStackSetup 4 } selectiveQinQEntry OBJECT-TYPE SYNTAX SelectiveQinQEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in selective qinq table" INDEX { selectiveQinQPort, selectiveQinQCvid } ::= { selectiveQinQTable 1 } SelectiveQinQEntry ::= SEQUENCE { selectiveQinQName DisplayString, selectiveQinQPort INTEGER, selectiveQinQCvid INTEGER, selectiveQinQSpvid INTEGER, selectiveQinQPriority INTEGER, selectiveQinQRowStatus RowStatus } selectiveQinQName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of selective qinq entry" ::= { selectiveQinQEntry 1 } selectiveQinQPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "interface port id" ::= { selectiveQinQEntry 2 } selectiveQinQCvid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "inner vid" ::= { selectiveQinQEntry 3 } selectiveQinQSpvid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "outer vid" ::= { selectiveQinQEntry 4 } selectiveQinQPriority OBJECT-TYPE SYNTAX INTEGER { prioriry-0(0), prioriry-1(1), prioriry-2(2), prioriry-3(3), prioriry-4(4), prioriry-5(5), prioriry-6(6), prioriry-7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "priority" ::= { selectiveQinQEntry 5 } selectiveQinQRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { selectiveQinQEntry 6 } -- diffservSetup diffservSetup OBJECT IDENTIFIER ::= { mgs3712 39 } diffservState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { diffservSetup 1 } -- diffservMapTable diffservMapTable OBJECT-TYPE SYNTAX SEQUENCE OF DiffservMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { diffservSetup 2 } diffservMapEntry OBJECT-TYPE SYNTAX DiffservMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in diffservMapTable." INDEX { diffservMapDscp } ::= { diffservMapTable 1 } DiffservMapEntry ::= SEQUENCE { diffservMapDscp INTEGER, diffservMapPriority INTEGER } diffservMapDscp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0-63" ::= { diffservMapEntry 1 } diffservMapPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0-7" ::= { diffservMapEntry 2 } -- diffservPortTable diffservPortTable OBJECT-TYPE SYNTAX SEQUENCE OF DiffservPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { diffservSetup 3 } diffservPortEntry OBJECT-TYPE SYNTAX DiffservPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in diffservPortTable." INDEX { dot1dBasePort } ::= { diffservPortTable 1 } DiffservPortEntry ::= SEQUENCE { diffservPortState EnabledStatus } diffservPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { diffservPortEntry 1 } -- protocol-based VLAN protoBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 40 } protoBasedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF ProtoBasedVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanSetup 1 } protoBasedVlanEntry OBJECT-TYPE SYNTAX ProtoBasedVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in protoBasedVlanTable." INDEX { protoBasedVlanPort, protoBasedVlanPacketType, protoBasedVlanEtherType } ::= { protoBasedVlanTable 1 } ProtoBasedVlanEntry ::= SEQUENCE { protoBasedVlanPort INTEGER, protoBasedVlanPacketType INTEGER, protoBasedVlanEtherType INTEGER, protoBasedVlanName DisplayString, protoBasedVlanVid INTEGER, protoBasedVlanPriority INTEGER, protoBasedVlanState RowStatus } protoBasedVlanPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 1 } protoBasedVlanPacketType OBJECT-TYPE SYNTAX INTEGER { etherII(1), snap(2), llc(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 2 } protoBasedVlanEtherType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 3 } protoBasedVlanName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 4 } protoBasedVlanVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 5 } protoBasedVlanPriority OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 6 } protoBasedVlanState OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { protoBasedVlanEntry 7 } --------------------------------------------------- -- -- dhcp snooping -- --------------------------------------------------- dhcpSnp OBJECT IDENTIFIER ::= { mgs3712 100 } -- -- dhcp snooping vlan table -- dhcpSnpVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpSnpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dhcpSnp 1 } dhcpSnpVlanEntry OBJECT-TYPE SYNTAX DhcpSnpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { dhcpSnpVlanEntryVid } ::= { dhcpSnpVlanTable 1 } DhcpSnpVlanEntry ::= SEQUENCE { dhcpSnpVlanEntryVid INTEGER, dhcpSnpVlanEntryEnable EnabledStatus, dhcpSnpVlanEntryOption82Enable EnabledStatus, dhcpSnpVlanEntryInfo EnabledStatus } dhcpSnpVlanEntryVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpVlanEntry 1 } dhcpSnpVlanEntryEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpVlanEntry 2 } dhcpSnpVlanEntryOption82Enable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpVlanEntry 3 } dhcpSnpVlanEntryInfo OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpVlanEntry 4 } -- -- dhcp snooping interface table -- dhcpSnpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpSnpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dhcpSnp 2 } dhcpSnpPortEntry OBJECT-TYPE SYNTAX DhcpSnpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { dhcpSnpPortEntryPort } ::= { dhcpSnpPortTable 1 } DhcpSnpPortEntry ::= SEQUENCE { dhcpSnpPortEntryPort INTEGER, dhcpSnpPortEntryTrust EnabledStatus, dhcpSnpPortEntryRate INTEGER } dhcpSnpPortEntryPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpPortEntry 1 } dhcpSnpPortEntryTrust OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpPortEntry 2 } dhcpSnpPortEntryRate OBJECT-TYPE SYNTAX INTEGER (0..2048) ACCESS read-write STATUS mandatory DESCRIPTION "0 means unlimited" ::= { dhcpSnpPortEntry 3 } -- -- dhcp snooping binding table -- dhcpSnpBindTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpSnpBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dhcpSnp 3 } dhcpSnpBindEntry OBJECT-TYPE SYNTAX DhcpSnpBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { dhcpSnpBindEntryMac, dhcpSnpBindEntryVid } ::= { dhcpSnpBindTable 1 } DhcpSnpBindEntry ::= SEQUENCE { dhcpSnpBindEntryMac MacAddress, dhcpSnpBindEntryVid INTEGER, dhcpSnpBindEntryIP IpAddress, dhcpSnpBindEntryLease INTEGER, dhcpSnpBindEntryType INTEGER, dhcpSnpBindEntryPort INTEGER } dhcpSnpBindEntryMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 1 } dhcpSnpBindEntryVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 2 } dhcpSnpBindEntryIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 3 } dhcpSnpBindEntryLease OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 4 } dhcpSnpBindEntryType OBJECT-TYPE SYNTAX INTEGER { dynamic(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 5 } dhcpSnpBindEntryPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpBindEntry 6 } -- -- dhcp snooping -- dhcpSnpEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnp 4 } -- -- dhcp snooping database -- dhcpSnpDb OBJECT IDENTIFIER ::= { dhcpSnp 5 } dhcpSnpDbAbort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDb 1 } dhcpSnpDbWriteDelay OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDb 2 } dhcpSnpDbUrl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDb 3 } dhcpSnpDbUrlRenew OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDb 4 } dhcpSnpDbStat OBJECT IDENTIFIER ::= { dhcpSnpDb 5 } dhcpSnpDbStatClear OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 1 } dhcpSnpDbStatAgentRunning OBJECT-TYPE SYNTAX INTEGER { none(0), read(1), write(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 2 } dhcpSnpDbStatDelayExpiry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 3 } dhcpSnpDbStatAbortExpiry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 4 } dhcpSnpDbStatLastSuccTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 5 } dhcpSnpDbStatLastFailTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 6 } dhcpSnpDbStatLastFailReason OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 7 } dhcpSnpDbStatTotalAttempt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 8 } dhcpSnpDbStatStartupFail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 9 } dhcpSnpDbStatSuccTrans OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 10 } dhcpSnpDbStatFailTrans OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 11 } dhcpSnpDbStatSuccRead OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 12 } dhcpSnpDbStatFailRead OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 13 } dhcpSnpDbStatSuccWrite OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 14 } dhcpSnpDbStatFailWrite OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 15 } dhcpSnpDbStatFirstSuccAccess OBJECT-TYPE SYNTAX INTEGER { none(0), read(1), write(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { dhcpSnpDbStat 16 } dhcpSnpDbStatLastIgnoreBindCol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last ignored: binding collision" ::= { dhcpSnpDbStat 17 } dhcpSnpDbStatLastIgnoreExpireLease OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last ignored: expired leases" ::= { dhcpSnpDbStat 18 } dhcpSnpDbStatLastIgnoreInvalidIntf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last ignored: invalid interface" ::= { dhcpSnpDbStat 19 } dhcpSnpDbStatLastIgnoreUnsuppVlan OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last ignored: unsupported vlans" ::= { dhcpSnpDbStat 20 } dhcpSnpDbStatLastIgnoreParse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last ignored: parsing error" ::= { dhcpSnpDbStat 21 } dhcpSnpDbStatTotalIgnoreBindCol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total ignored: binding collision" ::= { dhcpSnpDbStat 22 } dhcpSnpDbStatTotalIgnoreExpireLease OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total ignored: expired leases" ::= { dhcpSnpDbStat 23 } dhcpSnpDbStatTotalIgnoreInvalidIntf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total ignored: invalid interface" ::= { dhcpSnpDbStat 24 } dhcpSnpDbStatTotalIgnoreUnsuppVlan OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total ignored: unsupported vlans" ::= { dhcpSnpDbStat 25 } dhcpSnpDbStatTotalIgnoreParse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total ignored: parsing error" ::= { dhcpSnpDbStat 26 } dhcpSnpDbStatFirstSuccessAccess OBJECT-TYPE SYNTAX INTEGER{ none(0), read(1), write(2) } ACCESS read-only STATUS mandatory DESCRIPTION "First Success Access" ::={ dhcpSnpDbStat 27} -- -- dhcp snooping dhcp vlan -- dhcpSnpDhcpVlan OBJECT IDENTIFIER ::= { dhcpSnp 6 } dhcpSnpDhcpVlanVid OBJECT-TYPE SYNTAX INTEGER (0..4094) ACCESS read-write STATUS mandatory DESCRIPTION "0: disable DHCP VLAN." ::= { dhcpSnpDhcpVlan 1 } ----------------------------------------------------------------- -- -- ip source guard -- ----------------------------------------------------------------- ipsg OBJECT IDENTIFIER ::= { mgs3712 101 } ipsgTable OBJECT-TYPE SYNTAX SEQUENCE OF IpsgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { ipsg 1 } ipsgEntry OBJECT-TYPE SYNTAX IpsgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { ipsgEntryMac, ipsgEntryVid } ::= { ipsgTable 1 } IpsgEntry ::= SEQUENCE { ipsgEntryMac MacAddress, ipsgEntryVid INTEGER, ipsgEntryIp IpAddress, ipsgEntryLease INTEGER, ipsgEntryType INTEGER, ipsgEntryPort INTEGER, ipsgEntryState RowStatus } ipsgEntryMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { ipsgEntry 1 } ipsgEntryVid OBJECT-TYPE SYNTAX INTEGER (1.. 4094) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { ipsgEntry 2 } ipsgEntryIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { ipsgEntry 3 } ipsgEntryLease OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "second" ::= { ipsgEntry 4 } ipsgEntryType OBJECT-TYPE SYNTAX INTEGER { static(1), dhcp(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { ipsgEntry 5 } ipsgEntryPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0 means any port" ::= { ipsgEntry 6 } ipsgEntryState OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { ipsgEntry 7 } ----------------------------------------------------------------- -- -- arpInspect -- ----------------------------------------------------------------- arpInspect OBJECT IDENTIFIER ::= { mgs3712 102 } arpInspectSetup OBJECT IDENTIFIER ::= { arpInspect 1 } arpInspectState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectSetup 1 } arpInspectFilterAgingTime OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectSetup 2 } arpInspectLog OBJECT IDENTIFIER ::= { arpInspectSetup 3 } arpInspectLogEntries OBJECT-TYPE SYNTAX INTEGER (0..1024) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectLog 1 } arpInspectLogRate OBJECT-TYPE SYNTAX INTEGER (0..1024) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectLog 2 } arpInspectLogInterval OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectLog 3 } --arpInspectVlanTable arpInspectVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpInspectVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInspectSetup 4 } arpInspectVlanEntry OBJECT-TYPE SYNTAX ArpInspectVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { arpInspectVlanVid } ::= { arpInspectVlanTable 1 } ArpInspectVlanEntry ::= SEQUENCE { arpInspectVlanVid INTEGER, arpInspectVlanLog INTEGER, arpInspectVlanStatus INTEGER } arpInspectVlanVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectVlanEntry 1 } arpInspectVlanLog OBJECT-TYPE SYNTAX INTEGER { all (1), none (2), permit (3), deny (4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectVlanEntry 2 } arpInspectVlanStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectVlanEntry 3 } --arpInspectPortTable arpInspectPortTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpInspectPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInspectSetup 5 } arpInspectPortEntry OBJECT-TYPE SYNTAX ArpInspectPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { arpInspectPortIndex } ::= { arpInspectPortTable 1 } ArpInspectPortEntry ::= SEQUENCE { arpInspectPortIndex INTEGER, arpInspectPortTrust INTEGER, arpInspectPortRate INTEGER, arpInspectPortInterval INTEGER } arpInspectPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectPortEntry 1 } arpInspectPortTrust OBJECT-TYPE SYNTAX INTEGER { trusted(1), untrusted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectPortEntry 2 } arpInspectPortRate OBJECT-TYPE SYNTAX INTEGER (0..2048) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectPortEntry 3 } arpInspectPortInterval OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectPortEntry 4 } arpInspectStatus OBJECT IDENTIFIER ::= { arpInspect 2 } arpInspectFilterClear OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectStatus 1 } arpInspectLogClear OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectStatus 2 } --arpInspectFilterTable arpInspectFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpInspectFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInspectStatus 3 } arpInspectFilterEntry OBJECT-TYPE SYNTAX ArpInspectFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { arpInspectFilterMac, arpInspectFilterVid } ::= { arpInspectFilterTable 1 } ArpInspectFilterEntry ::= SEQUENCE { arpInspectFilterMac MacAddress, arpInspectFilterVid INTEGER, arpInspectFilterPort INTEGER, arpInspectFilterExpiry INTEGER, arpInspectFilterReason INTEGER, arpInspectFilterRowStatus RowStatus } arpInspectFilterMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 1 } arpInspectFilterVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 2 } arpInspectFilterPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 3 } arpInspectFilterExpiry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 4 } arpInspectFilterReason OBJECT-TYPE SYNTAX INTEGER { macVid(1), port(2), ip(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 5 } arpInspectFilterRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { arpInspectFilterEntry 6 } --arpInspectLogTable arpInspectLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpInspectLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInspectStatus 4 } arpInspectLogEntry OBJECT-TYPE SYNTAX ArpInspectLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { arpInspectLogMac, arpInspectLogVid, arpInspectLogPort, arpInspectLogIp, arpInspectLogReason } ::= { arpInspectLogTable 1 } ArpInspectLogEntry ::= SEQUENCE { arpInspectLogMac MacAddress, arpInspectLogVid INTEGER, arpInspectLogPort INTEGER, arpInspectLogIp IpAddress, arpInspectLogNumPkt INTEGER, arpInspectLogReason INTEGER, arpInspectLogTime DateAndTime } arpInspectLogMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 1 } arpInspectLogVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 2 } arpInspectLogPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 3 } arpInspectLogIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 4 } arpInspectLogNumPkt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 5 } arpInspectLogReason OBJECT-TYPE SYNTAX INTEGER { deny (1), denyStatic (2), denyDHCP (3), permitStatic (4), permitDHCP (5) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 6 } arpInspectLogTime OBJECT-TYPE SYNTAX DateAndTime ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectLogEntry 7 } --arpInspectStatisticsTable arpInspectStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF ArpInspectStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { arpInspectStatus 5 } arpInspectStatisticsEntry OBJECT-TYPE SYNTAX ArpInspectStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { arpInspectStatisticsVid } ::= { arpInspectStatisticsTable 1 } ArpInspectStatisticsEntry ::= SEQUENCE { arpInspectStatisticsVid INTEGER, arpInspectStatisticsReceived Counter, arpInspectStatisticsRequest Counter, arpInspectStatisticsReply Counter, arpInspectStatisticsForward Counter, arpInspectStatisticsDrop Counter, arpInspectStatisticsClear EnabledStatus } arpInspectStatisticsVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 1 } arpInspectStatisticsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 2 } arpInspectStatisticsRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 3 } arpInspectStatisticsReply OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 4 } arpInspectStatisticsForward OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 5 } arpInspectStatisticsDrop OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 6 } arpInspectStatisticsClear OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { arpInspectStatisticsEntry 7 } -- trTCMSetup trTCMSetup OBJECT IDENTIFIER ::= { mgs3712 103 } trTCMState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Two-rate three color marker enabled/disabled for the switch." ::= { trTCMSetup 1 } trTCMMode OBJECT-TYPE SYNTAX INTEGER { color-aware(0), color-blind(1) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { trTCMSetup 2 } -- trTCMPortTable trTCMPortTable OBJECT-TYPE SYNTAX SEQUENCE OF TrTCMPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { trTCMSetup 3 } trTCMPortEntry OBJECT-TYPE SYNTAX TrTCMPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in trTCMPortTable." INDEX { dot1dBasePort } ::= { trTCMPortTable 1 } TrTCMPortEntry ::= SEQUENCE { trTCMPortState EnabledStatus, trTCMPortCIR INTEGER, trTCMPortPIR INTEGER, trTCMPortDscpGreen INTEGER, trTCMPortDscpYellow INTEGER, trTCMPortDscpRed INTEGER } trTCMPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-create STATUS mandatory DESCRIPTION "Two-rate three color marker enabled/disabled on the port." ::= { trTCMPortEntry 1 } trTCMPortCIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allowed CIR in pkts/s." ::= { trTCMPortEntry 2 } trTCMPortPIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allowed PIR in pkts/s." ::= { trTCMPortEntry 3 } trTCMPortDscpGreen OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0-63" ::= { trTCMPortEntry 4 } trTCMPortDscpYellow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0-63" ::= { trTCMPortEntry 5 } trTCMPortDscpRed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "0-63" ::= { trTCMPortEntry 6 } -- loopGuardSetup loopGuardSetup OBJECT IDENTIFIER ::= { mgs3712 104 } loopGuardState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { loopGuardSetup 1 } -- loopGuardPortTable loopGuardPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopGuardPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { loopGuardSetup 2 } loopGuardPortEntry OBJECT-TYPE SYNTAX LoopGuardPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in loopGuardPortTable." INDEX { dot1dBasePort } ::= { loopGuardPortTable 1 } LoopGuardPortEntry ::= SEQUENCE { loopGuardPortState EnabledStatus } loopGuardPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { loopGuardPortEntry 1 } -- subnetBasedVlanSetup subnetBasedVlanSetup OBJECT IDENTIFIER ::= { mgs3712 105 } subnetBasedVlanState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "subnet-based vlan feature enabled/disabled for the switch." ::= { subnetBasedVlanSetup 1 } dhcpVlanOverrideState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "dhcp vlan override enabled/disabled when subnet-based vlan is enabled." ::= { subnetBasedVlanSetup 2 } subnetBasedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF SubnetBasedVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { subnetBasedVlanSetup 3 } subnetBasedVlanEntry OBJECT-TYPE SYNTAX SubnetBasedVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in subnetBasedVlanTable." INDEX {subnetBasedVlanSrcIp , subnetBasedVlanSrcMaskBit} ::= { subnetBasedVlanTable 1 } SubnetBasedVlanEntry ::= SEQUENCE { subnetBasedVlanSrcIp IpAddress, subnetBasedVlanSrcMaskBit INTEGER, subnetBasedVlanName DisplayString, subnetBasedVlanVid INTEGER, subnetBasedVlanPriority INTEGER, subnetBasedVlanEntryState RowStatus } subnetBasedVlanSrcIp OBJECT-TYPE SYNTAX IpAddress ACCESS not-accessible STATUS mandatory DESCRIPTION "source ip for subnet-based vlan entry" ::= { subnetBasedVlanEntry 1 } subnetBasedVlanSrcMaskBit OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS not-accessible STATUS mandatory DESCRIPTION "source ip mask-bits for subnet-based vlan entry" ::= { subnetBasedVlanEntry 2 } subnetBasedVlanName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "name for subnet-based vlan entry" ::= { subnetBasedVlanEntry 3 } subnetBasedVlanVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "vid for subnet-based vlan entry" ::= { subnetBasedVlanEntry 4 } subnetBasedVlanPriority OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "priority for subnet-based vlan entry" ::= { subnetBasedVlanEntry 5 } subnetBasedVlanEntryState OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { subnetBasedVlanEntry 6 } -- MAC Authentication macAuthenticationSetup OBJECT IDENTIFIER ::= { mgs3712 106 } macAuthenticationState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { macAuthenticationSetup 1 } macAuthenticationNamePrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { macAuthenticationSetup 2 } macAuthenticationPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { macAuthenticationSetup 3 } macAuthenticationTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { macAuthenticationSetup 4 } -- macAuthenticationPortTable macAuthenticationPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MacAuthenticationPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { macAuthenticationSetup 5 } macAuthenticationPortEntry OBJECT-TYPE SYNTAX MacAuthenticationPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in macAuthenticationPortTable." INDEX { dot1dBasePort } ::= { macAuthenticationPortTable 1 } MacAuthenticationPortEntry ::= SEQUENCE { macAuthenticationPortState EnabledStatus } macAuthenticationPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { macAuthenticationPortEntry 1 } -- MSTP mstp OBJECT IDENTIFIER ::= { mgs3712 107 } -- mstpGen group reflects configurations/statuses -- the Bridge as a unit mstpGen OBJECT IDENTIFIER ::= { mstp 1} mstpGenState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Enabled/disabled on the mrstp bridge." ::= { mstpGen 1 } mstpGenCfgIdName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The configuration name that identifies the MST region and is used as one of the inputs in the computation of the MST Configuration Identifier." REFERENCE "12.12.3.4.2.b)" ::= { mstpGen 2 } mstpGenCfgIdRevLevel OBJECT-TYPE SYNTAX Integer32 ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the MST revision that identifies the MST region and is used as one of the inputs in the computation of the MST configuration Identifier." REFERENCE "12.12.3.4.2.c)" ::= { mstpGen 3 } mstpGenCfgIdCfgDigest OBJECT-TYPE SYNTAX OCTET STRING(SIZE(16)) ACCESS read-only STATUS mandatory DESCRIPTION "Configuration Digest." REFERENCE "12.12.3.3.3.a.4" ::= { mstpGen 4 } mstpGenHelloTime OBJECT-TYPE SYNTAX Timeout (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mstpGen 5 } mstpGenMaxAge OBJECT-TYPE SYNTAX Timeout (6..40) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mstpGen 6 } mstpGenForwardDelay OBJECT-TYPE SYNTAX Timeout (4..30) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= {mstpGen 7} mstpGenMaxHops OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS mandatory DESCRIPTION "13.22.f)" ::= { mstpGen 8 } mstpGenCistRootPathCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpGen 9 } mstpGenCistRootBrid OBJECT-TYPE SYNTAX OCTET STRING(SIZE(8)) MAX-ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpGen 10 } -- MSTP MAP TABLE mstMapTable OBJECT-TYPE SYNTAX SEQUENCE OF MstMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains one entry for each instance of MSTP." ::= { mstp 20 } mstMapEntry OBJECT-TYPE SYNTAX MstMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row containing the status of the MSTP instance." INDEX { mstMapIndex } ::= { mstMapTable 1 } MstMapEntry ::= SEQUENCE { mstMapIndex MstiOrCistInstanceIndex, mstMapVlans1k OCTET STRING, mstMapVlans2k OCTET STRING, mstMapVlans3k OCTET STRING, mstMapVlans4k OCTET STRING, mstMapRowStatus RowStatus } mstMapIndex OBJECT-TYPE SYNTAX MstiOrCistInstanceIndex MAX-ACCESS not-accessible STATUS mandatory DESCRIPTION "Uniquely identifies an instance. The entry of this table with index 0 presents always, represents CIST. When SET operation " ::= { mstMapEntry 1 } mstMapVlans1k OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values 1 through 8; the second octet to VLANs 9 through 16 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory." ::= { mstMapEntry 2 } mstMapVlans2k OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "A string of octets containing one bit per VLAN for VLANS with VlanIndex values 1024 through 2047. The first octet corresponds to VLANs with VlanIndex values 1024 through 1031; the second octet to VLANs 1032 through 1039 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory." ::= { mstMapEntry 3 } mstMapVlans3k OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) ACCESS read-write STATUS current DESCRIPTION "A string of octets containing one bit per VLAN for VLANS with VlanIndex values 2048 through 3071. The first octet corresponds to VLANs with VlanIndex values of 2048 through 2055; the second octet to VLANs 2056 through 2063 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory." ::= { mstMapEntry 4 } mstMapVlans4k OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "A string of octets containing one bit per VLAN for VLANS with VlanIndex values 3072 through 4095. The first octet corresponds to VLANs with VlanIndex values 3072 through 3079; the second octet to VLANs 3080 through 3087 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory." ::= { mstMapEntry 5 } mstMapRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { mstMapEntry 6 } -- MSTP Vlan Table, map vlan to msti mstVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF MstVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains one entry for each VlanId." ::= { mstp 30 } mstVlanEntry OBJECT-TYPE SYNTAX MstVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information regarding the instance to which each Vlan is mapped." INDEX { mstVlanIndex } ::= { mstVlanTable 1 } MstVlanEntry ::= SEQUENCE { mstVlanIndex INTEGER, mstVlanMstIndex MstiOrCistInstanceIndex } mstVlanIndex OBJECT-TYPE SYNTAX INTEGER(1..4094) ACCESS not-accessible STATUS mandatory DESCRIPTION "The VlanId for which this entry contains the instance mapped." ::= { mstVlanEntry 1 } mstVlanMstIndex OBJECT-TYPE SYNTAX MstiOrCistInstanceIndex ACCESS read-only STATUS mandatory DESCRIPTION "An integer with values ranging from 0 to 64 that identify a the CIST/MSTI instance to which this VLAN is mapped" ::= { mstVlanEntry 2 } -- MSTP Port Table, information for all instance of a port mstpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MstpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains generic information about every port that is associated with this bridge." ::= { mstp 40 } mstpPortEntry OBJECT-TYPE SYNTAX MstpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information for each port of the bridge." INDEX { mstpPortIndex } ::= { mstpPortTable 1 } MstpPortEntry ::= SEQUENCE { mstpPortIndex INTEGER, mstpPortOperEdgePort TruthValue, mstpPortOperPointToPointMAC TruthValue } mstpPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique value, greater than zero, for each Port. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { mstpPortEntry 1 } mstpPortOperEdgePort OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "" REFERENCE "" ::= { mstpPortEntry 2 } mstpPortOperPointToPointMAC OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "" REFERENCE "" ::= {mstpPortEntry 3} -- MSTP Xst Table, Cist/Mst status/setting mstpXstTable OBJECT-TYPE SYNTAX SEQUENCE OF MstpXstEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { mstp 50 } mstpXstEntry OBJECT-TYPE SYNTAX MstpXstEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." INDEX { mstpXstId } ::= { mstpXstTable 1 } MstpXstEntry ::= SEQUENCE { mstpXstId MstiOrCistInstanceIndex, mstpXstBridgePriority Integer32, mstpXstBridgeId BridgeId, mstpXstInternalRootCost Integer32, mstpXstRootPort INTEGER, mstpXstTimeSinceTopologyChange TimeTicks, mstpXstTopologyChangesCount Counter32 } mstpXstId OBJECT-TYPE SYNTAX MstiOrCistInstanceIndex ACCESS read-only STATUS mandatory DESCRIPTION "0 means CIST." ::= { mstpXstEntry 1 } mstpXstBridgePriority OBJECT-TYPE SYNTAX Integer32 (0..61440) ACCESS read-write STATUS mandatory DESCRIPTION "Bridge priority, in steps of 4096." DEFVAL { 32768 } ::= { mstpXstEntry 2 } mstpXstBridgeId OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstEntry 3 } mstpXstInternalRootCost OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstEntry 4 } mstpXstRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstEntry 5 } mstpXstTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstEntry 6 } mstpXstTopologyChangesCount OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstEntry 7 } -- MSTP Xst Port Table, Cist/Mst Port status/setting mstpXstPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MstpXstPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { mstp 60 } mstpXstPortEntry OBJECT-TYPE SYNTAX MstpXstPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." REFERENCE "." INDEX { mstpXstPortXstId, mstpXstPortIndex } ::= { mstpXstPortTable 1 } MstpXstPortEntry ::= SEQUENCE { mstpXstPortXstId MstiOrCistInstanceIndex, mstpXstPortIndex INTEGER, mstpXstPortEnable EnabledStatus, mstpXstPortPriority Integer32, mstpXstPortPathCost INTEGER, mstpXstPortState INTEGER, mstpXstPortDesignatedRoot BridgeId, mstpXstPortDesignatedCost Integer32, mstpXstPortDesignatedBridge BridgeId, mstpXstPortDesignatedPort INTEGER } mstpXstPortXstId OBJECT-TYPE SYNTAX MstiOrCistInstanceIndex ACCESS not-accessible STATUS mandatory DESCRIPTION "0 means CIST." ::= { mstpXstPortEntry 1 } mstpXstPortIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of mstpPortIndex of the Port in mstpPortTable." ::= { mstpXstPortEntry 2 } mstpXstPortEnable OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 3 } mstpXstPortPriority OBJECT-TYPE SYNTAX Integer32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Port priority, in steps of 16." DEFVAL { 128 } ::= { mstpXstPortEntry 4 } mstpXstPortPathCost OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 5 } mstpXstPortState OBJECT-TYPE SYNTAX INTEGER { disabled(0), discarding(1), learning(2), forwarding(3), unknown(4) } ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 6 } mstpXstPortDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 7 } mstpXstPortDesignatedCost OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 8 } mstpXstPortDesignatedBridge OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 9 } mstpXstPortDesignatedPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { mstpXstPortEntry 10 } --MSTP Traps mstpNotifications OBJECT IDENTIFIER ::= { mstp 70 } newRoot NOTIFICATION-TYPE OBJECTS { mstpXstId } STATUS current DESCRIPTION "" ::= { mstpNotifications 1 } topologyChange NOTIFICATION-TYPE OBJECTS { mstpXstId } STATUS current DESCRIPTION "" ::= { mstpNotifications 2 } --------------------------------------------------- -- -- Port Isolation -- --------------------------------------------------- -- portIsolationTable portIsolationSetup OBJECT IDENTIFIER ::= { mgs3712 112 } portIsolationTable OBJECT-TYPE SYNTAX SEQUENCE OF PortIsolationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { portIsolationSetup 1 } portIsolationEntry OBJECT-TYPE SYNTAX PortIsolationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in portIsolationTable." INDEX { dot1dBasePort } ::= { portIsolationTable 1 } PortIsolationEntry ::= SEQUENCE { portIsolationState EnabledStatus } portIsolationState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "Port isolation enabled/disabled on the port. Enable(1) to be isolated and not exchange packets." ::= { portIsolationEntry 1 } --------------------------------------------------- -- -- Layer 2 Protocol Tunneling -- --------------------------------------------------- l2ptSetup OBJECT IDENTIFIER ::= { mgs3712 115 } -- l2ptState l2ptState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "L2PT feature enabled/disabled for the switch" ::= { l2ptSetup 1 } l2ptMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "L2PT destination mac address" ::= { l2ptSetup 2 } -- l2ptTable l2ptTable OBJECT-TYPE SYNTAX SEQUENCE OF L2ptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { l2ptSetup 3 } l2ptEntry OBJECT-TYPE SYNTAX L2ptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in l2ptTable." INDEX { dot1dBasePort } ::= { l2ptTable 1 } L2ptEntry ::= SEQUENCE { l2ptProtocolGroup BITS, l2ptPointToPointProtocolGroup BITS, l2ptMode INTEGER } l2ptProtocolGroup OBJECT-TYPE SYNTAX BITS { cdp(0), stp(1), vtp(2) } ACCESS read-write STATUS mandatory DESCRIPTION "L2PT protocols enabled/disabled on the port" ::= { l2ptEntry 1 } l2ptPointToPointProtocolGroup OBJECT-TYPE SYNTAX BITS { pagp(0), lacp(1), udld(2) } ACCESS read-write STATUS mandatory DESCRIPTION "L2PT point-to-point protocols enabled/disabled on the port" ::= { l2ptEntry 2 } l2ptMode OBJECT-TYPE SYNTAX INTEGER { access(1), tunnel(2) } ACCESS read-write STATUS mandatory DESCRIPTION "L2PT port role on the port" ::= { l2ptEntry 3 } --------------------------------------------------- -- -- vlan mapping -- --------------------------------------------------- -- vlanMappingSetup vlanMappingSetup OBJECT IDENTIFIER ::= { mgs3712 116 } vlanMappingState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { vlanMappingSetup 1 } -- vlanMappingPortTable vlanMappingPortTable OBJECT-TYPE SYNTAX SEQUENCE OF VlanMappingPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { vlanMappingSetup 2 } vlanMappingPortEntry OBJECT-TYPE SYNTAX VlanMappingPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in vlanMappingPortTable." INDEX { dot1dBasePort } ::= { vlanMappingPortTable 1 } VlanMappingPortEntry ::= SEQUENCE { vlanMappingPortState EnabledStatus } vlanMappingPortState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { vlanMappingPortEntry 1 } -- vlanMappingRuleTable vlanMappingRuleTable OBJECT-TYPE SYNTAX SEQUENCE OF VlanMappingRuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { vlanMappingSetup 3 } vlanMappingRuleEntry OBJECT-TYPE SYNTAX VlanMappingRuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in vlan-mapping rule table" INDEX { vlanMappingRulePort, vlanMappingRuleVid } ::= { vlanMappingRuleTable 1 } VlanMappingRuleEntry ::= SEQUENCE { vlanMappingRuleName DisplayString, vlanMappingRulePort INTEGER, vlanMappingRuleVid INTEGER, vlanMappingRuleTransVid INTEGER, vlanMappingRulePriority INTEGER, vlanMappingRuleRowStatus RowStatus } vlanMappingRuleName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of vlan-mapping entry" ::= { vlanMappingRuleEntry 1 } vlanMappingRulePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "interface port id" ::= { vlanMappingRuleEntry 2 } vlanMappingRuleVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "inner vid" ::= { vlanMappingRuleEntry 3 } vlanMappingRuleTransVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "translated vid" ::= { vlanMappingRuleEntry 4 } vlanMappingRulePriority OBJECT-TYPE SYNTAX INTEGER { prioriry-0(0), prioriry-1(1), prioriry-2(2), prioriry-3(3), prioriry-4(4), prioriry-5(5), prioriry-6(6), prioriry-7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "priority" ::= { vlanMappingRuleEntry 5 } vlanMappingRuleRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-create STATUS mandatory DESCRIPTION "" ::= { vlanMappingRuleEntry 6 } -- transceiverInfoTable transceiverInfo OBJECT IDENTIFIER ::= { mgs3712 117 } -- transceiverSerialInfoTable transceiverSerialInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF TransceiverSerialInfoEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { transceiverInfo 1 } transceiverSerialInfoEntry OBJECT-TYPE SYNTAX TransceiverSerialInfoEntry ACCESS not-accessible STATUS current DESCRIPTION "An entry in transceiverSerialInfoTable." INDEX { transceiverSerialInfoEntryPort } ::= { transceiverSerialInfoTable 1 } TransceiverSerialInfoEntry ::= SEQUENCE { transceiverSerialInfoEntryPort INTEGER, transceiverSerialInfoEntryStatus INTEGER, transceiverSerialInfoEntryVendor DisplayString, transceiverSerialInfoEntryPartNo DisplayString, transceiverSerialInfoEntrySerialNo DisplayString, transceiverSerialInfoEntryRevision DisplayString, transceiverSerialInfoEntryDateCode DisplayString, transceiverSerialInfoEntryTransceiver DisplayString } transceiverSerialInfoEntryPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Index of transceiverSerialInfo. It is referred to dot1dBasePort" ::= { transceiverSerialInfoEntry 1 } transceiverSerialInfoEntryStatus OBJECT-TYPE SYNTAX INTEGER { ok_with_DDM(1), ok_without_DDM(2), nonoperational(3) } ACCESS read-only STATUS current DESCRIPTION "Transceiver module status." ::= { transceiverSerialInfoEntry 2 } transceiverSerialInfoEntryVendor OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Transceiver module vendor name." ::= { transceiverSerialInfoEntry 3 } transceiverSerialInfoEntryPartNo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Part number provided by transceiver module vendor." ::= { transceiverSerialInfoEntry 4 } transceiverSerialInfoEntrySerialNo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Serial number provided by transceiver module vendor." ::= { transceiverSerialInfoEntry 5 } transceiverSerialInfoEntryRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Revision level for part number provided by transceiver module vendor." ::= { transceiverSerialInfoEntry 6 } transceiverSerialInfoEntryDateCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Transceiver module vendor's manufacturing date code" ::= { transceiverSerialInfoEntry 7 } transceiverSerialInfoEntryTransceiver OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Transceiver module type names" ::= { transceiverSerialInfoEntry 8 } -- transceiverDdmInfoTable transceiverDdmInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF TransceiverDdmInfoEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { transceiverInfo 2 } transceiverDdmInfoEntry OBJECT-TYPE SYNTAX TransceiverDdmInfoEntry ACCESS not-accessible STATUS current DESCRIPTION "An entry in transceiverDdmInfoTable." INDEX { transceiverDdmInfoEntryPort, transceiverDdmInfoEntryType } ::= { transceiverDdmInfoTable 1 } TransceiverDdmInfoEntry ::= SEQUENCE { transceiverDdmInfoEntryPort INTEGER, transceiverDdmInfoEntryType INTEGER, transceiverDdmInfoEntryAlarmMax INTEGER, transceiverDdmInfoEntryAlarmMin INTEGER, transceiverDdmInfoEntryWarnMax INTEGER, transceiverDdmInfoEntryWarnMin INTEGER, transceiverDdmInfoEntryCurrent INTEGER, transceiverDdmInfoEntryDescription DisplayString } transceiverDdmInfoEntryPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Index of transceiverDdmInfo. This will be referred to dot1dBasePort" ::= { transceiverDdmInfoEntry 1 } transceiverDdmInfoEntryType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Transceiver module status." ::= { transceiverDdmInfoEntry 2 } transceiverDdmInfoEntryAlarmMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Transceiver module vendor name." ::= { transceiverDdmInfoEntry 3 } transceiverDdmInfoEntryAlarmMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Part number provided by transceiver module vendor." ::= { transceiverDdmInfoEntry 4 } transceiverDdmInfoEntryWarnMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Serial number provided by transceiver module vendor." ::= { transceiverDdmInfoEntry 5 } transceiverDdmInfoEntryWarnMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Revision level for part number provided by transceiver module vendor." ::= { transceiverDdmInfoEntry 6 } transceiverDdmInfoEntryCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Transceiver module vendor's manufacturing date code" ::= { transceiverDdmInfoEntry 7 } transceiverDdmInfoEntryDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Transceiver module type names" ::= { transceiverDdmInfoEntry 8 } -- dot3OamSetup dot3OamSetup OBJECT IDENTIFIER ::= { mgs3712 118 } dot3OamState OBJECT-TYPE SYNTAX EnabledStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { dot3OamSetup 1 } -- dot3OamPortTable dot3OamPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3OamPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dot3OamSetup 2 } dot3OamPortEntry OBJECT-TYPE SYNTAX Dot3OamPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in dot3OamPortTable." INDEX { ifIndex } ::= { dot3OamPortTable 1 } Dot3OamPortEntry ::= SEQUENCE { dot3OamFunctionsSupported BITS } dot3OamFunctionsSupported OBJECT-TYPE SYNTAX BITS { unidirectionalSupport (0), loopbackSupport(1), eventSupport(2), variableSupport(3) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The OAM functions supported on this Ethernet-like interface. OAM consists of separate functional sets beyond the basic discovery process that is always required. These functional groups can be supported independently by any implementation. These values are communicated to the peer via the local configuration field of Information OAMPDUs. Setting 'unidirectionalSupport(0)' indicates that the OA entity supports the transmission of OAMPDUs on links that are operating in unidirectional mode (traffic flowing in one direction only). Setting 'loopbackSupport(1)' indicates that the OAM entity can initiate and respond to loopback commands. Setting 'eventSupport(2)' indicates that the OAM entity can send and receive Event Notification OAMPDUs. Setting 'variableSupport(3)' indicates that the OAM entity can send and receive Variable Request and Response OAMPDUs. " REFERENCE "[802.3ah], 30.3.6.1.6" ::= { dot3OamPortEntry 1 } -- dot1agCfmMib dot1agCfmSetup OBJECT IDENTIFIER ::= { mgs3712 119 } dot1agCfmMIBObjects OBJECT IDENTIFIER ::= { dot1agCfmSetup 1 } -- ****************************************************************** -- Groups in the CFM MIB Module -- ****************************************************************** dot1agCfmMep OBJECT IDENTIFIER ::= { dot1agCfmMIBObjects 7 } -- ****************************************************************** -- The MEP Table -- ****************************************************************** dot1agCfmMepTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot1agCfmMepEntry MAX-ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { dot1agCfmMep 1 } dot1agCfmMepEntry OBJECT-TYPE SYNTAX Dot1agCfmMepEntry MAX-ACCESS not-accessible STATUS mandatory DESCRIPTION "The dot1agCfmMep table entry" INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier } ::= { dot1agCfmMepTable 1 } Dot1agCfmMepEntry ::= SEQUENCE { dot1agCfmMepTransmitLbmDataTlvSize Unsigned32 } dot1agCfmMepTransmitLbmDataTlvSize OBJECT-TYPE SYNTAX Unsigned32 (0..1500) MAX-ACCESS read-write STATUS mandatory DESCRIPTION "Size of data to be included in the LBM Data TLV" REFERENCE "" ::= { dot1agCfmMepEntry 1 } END