-- DELL-SHADOW-MIB.mib
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
--	Version 1.0 - 24-Jan-2006
 | 
						|
--	Initial release
 | 
						|
--
 | 
						|
--	Version 1.1 - 02-Feb-2006
 | 
						|
--	Re-defined Shadow root OID;
 | 
						|
--  Added comments in notifications to add directives for trap classification
 | 
						|
--
 | 
						|
--	Version 1.2 - 15-March-2007
 | 
						|
--	library fault OIDs added
 | 
						|
--
 | 
						|
--	Version 1.3 - 14-Jan-2008
 | 
						|
--	changes done for SNMPv2 implementation:
 | 
						|
--  Added SNMPv1 trap definitions to MIB to decode v1 traps correct
 | 
						|
--
 | 
						|
--	Version 1.4 - 29-April-2009
 | 
						|
--	trap eventLoaderPasswordChange for Library password change added
 | 
						|
--  
 | 
						|
--	Version 1.6 - 16-September-2009
 | 
						|
--	trap eventEncryptionConfigChange for Library password change added
 | 
						|
--
 | 
						|
--	Version 1.7 - 25-March-2010
 | 
						|
--	trap eventLoaderConfigChange added
 | 
						|
--	trap eventBrowserLogin added
 | 
						|
--	trap eventBrowserLogout added
 | 
						|
--
 | 
						|
 | 
						|
  DELL-SHADOW-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
    IMPORTS 
 | 
						|
      OBJECT-TYPE      
 | 
						|
        FROM RFC-1212      
 | 
						|
      TRAP-TYPE      
 | 
						|
        FROM RFC-1215      
 | 
						|
      enterprises      
 | 
						|
        FROM RFC1155-SMI      
 | 
						|
      DisplayString      
 | 
						|
        FROM RFC1213-MIB;
 | 
						|
 | 
						|
--
 | 
						|
-- Node definitions
 | 
						|
--
 | 
						|
  
 | 
						|
    dell OBJECT IDENTIFIER ::= { enterprises 674 }
 | 
						|
    
 | 
						|
    storage OBJECT IDENTIFIER ::= { dell 10893 }
 | 
						|
    
 | 
						|
    hardware OBJECT IDENTIFIER ::= { storage 2 }
 | 
						|
    
 | 
						|
    shadow OBJECT IDENTIFIER ::= { hardware 102 }
 | 
						|
    
 | 
						|
---
 | 
						|
---	Product ID Group
 | 
						|
---
 | 
						|
    shadowId OBJECT IDENTIFIER ::= { shadow 1 }
 | 
						|
    
 | 
						|
    shadowIdDisplayName OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Name of this product for display purposes."
 | 
						|
      ::= { shadowId 1 }
 | 
						|
    
 | 
						|
    shadowIdDescription OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "A short description of this product such as <LTO Tape Library>."
 | 
						|
      ::= { shadowId 2 }
 | 
						|
    
 | 
						|
    shadowAgentVendor OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The name of the product manufacturer."
 | 
						|
      ::= { shadowId 3 }
 | 
						|
    
 | 
						|
    shadowIdAgentVersion OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The version of this product."
 | 
						|
      ::= { shadowId 4 }
 | 
						|
    
 | 
						|
    shadowIdBuildNumber OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The software build number of the product."
 | 
						|
      ::= { shadowId 5 }
 | 
						|
 | 
						|
    shadowIdURL OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The URL of the web-based application to manage this product."
 | 
						|
      ::= { shadowId 6 }
 | 
						|
 | 
						|
---
 | 
						|
---	Product Status Group
 | 
						|
---
 | 
						|
    shadowStatus OBJECT IDENTIFIER ::= { shadow 2 }
 | 
						|
    
 | 
						|
    shadowStatusGlobalStatus OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
        {
 | 
						|
        other(1),
 | 
						|
        unknown(2),
 | 
						|
        ok(3),
 | 
						|
        non-critical(4),
 | 
						|
        critical(5),
 | 
						|
        non-Recoverable(6)
 | 
						|
        }
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Current status of the product. 
 | 
						|
        This is a rollup for the entire agent including any 
 | 
						|
        monitored devices. The status is intended to give 
 | 
						|
        initiative to a snmp monitor to get further data when 
 | 
						|
        this status is abnormal."
 | 
						|
      ::= { shadowStatus 1 }
 | 
						|
    
 | 
						|
    shadowStatusLastGlobalStatus OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
        {
 | 
						|
        other(1),
 | 
						|
        unknown(2),
 | 
						|
        ok(3),
 | 
						|
        non-critical(4),
 | 
						|
        critical(5),
 | 
						|
        non-recoverable(6)
 | 
						|
        }
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The status before the current status which induced an initiative 
 | 
						|
        to issue a global status change trap."
 | 
						|
      ::= { shadowStatus 2 }
 | 
						|
    
 | 
						|
    shadowStatusTimeStamp OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "The last time that the agent values have been updated.
 | 
						|
        The time shoule be in a relative timestamp, such as SysUpTime."
 | 
						|
      ::= { shadowStatus 3 }
 | 
						|
    
 | 
						|
    shadowStatusGetTimeOut OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER (1..10000)
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Suggested time out value in milleseconds for how long the SNMP getter
 | 
						|
        should wait while attempting to poll the product SNMP service."
 | 
						|
      ::= { shadowStatus 4 }
 | 
						|
    
 | 
						|
    shadowStatusRefreshRate OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER (-1..1000000000)
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Rate in seconds at which the agent cached data is being updated. If the
 | 
						|
        value is 0 then the data is not cached. If the value is -1 then the value does
 | 
						|
        not apply."
 | 
						|
      ::= { shadowStatus 5 }
 | 
						|
    
 | 
						|
    shadowStatusGeneratingTrapFlag OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
        {
 | 
						|
        true(1),
 | 
						|
        false(2),
 | 
						|
        disabled(3)
 | 
						|
        }
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Indicates id this SNMP agent is capable of and/or is generating SNMP traps."
 | 
						|
      ::= { shadowStatus 6 }
 | 
						|
    
 | 
						|
---
 | 
						|
---	Physical Group
 | 
						|
---
 | 
						|
    shadowPhysical OBJECT IDENTIFIER ::= { shadow 3 }
 | 
						|
 | 
						|
    libraryTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF LibraryEntry
 | 
						|
      ACCESS not-accessible
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "A table of library status."
 | 
						|
      ::= { shadowPhysical 1 }
 | 
						|
    
 | 
						|
    libraryEntry OBJECT-TYPE
 | 
						|
      SYNTAX LibraryEntry
 | 
						|
      ACCESS not-accessible
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Entry in the library Table. Each entry contains
 | 
						|
        an index (libraryEntryId), and the values associated 
 | 
						|
        with the device."
 | 
						|
      INDEX { libraryEntryId }
 | 
						|
      ::= { libraryTable 1 }
 | 
						|
    
 | 
						|
    LibraryEntry ::=
 | 
						|
      SEQUENCE { 
 | 
						|
        libraryEntryId
 | 
						|
          INTEGER,
 | 
						|
        libraryState
 | 
						|
          INTEGER,
 | 
						|
        libraryTimeStamp
 | 
						|
          INTEGER,
 | 
						|
        libraryType
 | 
						|
          INTEGER,
 | 
						|
        libraryScsiId
 | 
						|
          INTEGER,
 | 
						|
	    libraryScsiLun
 | 
						|
          INTEGER,
 | 
						|
        libraryVendorId
 | 
						|
          DisplayString,
 | 
						|
        libraryProductId
 | 
						|
          DisplayString,
 | 
						|
        libraryFwLevel
 | 
						|
          DisplayString,
 | 
						|
        librarySerNum
 | 
						|
          DisplayString,
 | 
						|
        libraryDrvCnt
 | 
						|
          INTEGER,
 | 
						|
        librarySlotCnt
 | 
						|
          INTEGER,
 | 
						|
        libraryImpExpCnt
 | 
						|
          INTEGER,
 | 
						|
        libraryTranspCnt
 | 
						|
          INTEGER,
 | 
						|
        libraryMoves
 | 
						|
          INTEGER,
 | 
						|
        librarySlotFetchRetries
 | 
						|
          INTEGER,
 | 
						|
        librarySlotStowRetries
 | 
						|
          INTEGER,
 | 
						|
        libraryDrvFetchRetries
 | 
						|
          INTEGER,
 | 
						|
        libraryDrvStowRetries
 | 
						|
          INTEGER,
 | 
						|
        libraryDoorState
 | 
						|
          INTEGER,
 | 
						|
        libraryImpExpState
 | 
						|
          INTEGER,
 | 
						|
        libraryFaultFSC
 | 
						|
          INTEGER,
 | 
						|
        libraryFaultSev
 | 
						|
          INTEGER,
 | 
						|
        libraryFaultDescr
 | 
						|
          DisplayString
 | 
						|
       }
 | 
						|
 | 
						|
    libraryEntryId OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER (1..256)
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Table entry index value. Each unique physical device has a unique libraryEntryId."
 | 
						|
      ::= { libraryEntry 1 }
 | 
						|
    
 | 
						|
    libraryState OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device state."
 | 
						|
      ::= { libraryEntry 2 }
 | 
						|
    
 | 
						|
    libraryTimeStamp OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Relative time in sec from power-up."
 | 
						|
      ::= { libraryEntry 3 }
 | 
						|
    
 | 
						|
    libraryType OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device type."
 | 
						|
      ::= { libraryEntry 4 }
 | 
						|
    
 | 
						|
    libraryScsiId OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "SCSI ID of the device."
 | 
						|
      ::= { libraryEntry 5}
 | 
						|
    
 | 
						|
    libraryScsiLun OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "SCSI Lun of the device."
 | 
						|
      ::= { libraryEntry 6 }
 | 
						|
    
 | 
						|
    libraryVendorId OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Library Vendor ID string as reported in a SCSI Inquiry command."
 | 
						|
      ::= { libraryEntry 7 }
 | 
						|
    
 | 
						|
    libraryProductId OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Library Product Id string as reported in a SCSI Inquiry command."
 | 
						|
      ::= { libraryEntry 8 }
 | 
						|
    
 | 
						|
    libraryFwLevel OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Library Firmware level as reported in a SCSI Inquiry command."
 | 
						|
      ::= { libraryEntry 9 }
 | 
						|
    
 | 
						|
    librarySerNum OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Library serial number as reported in SCSI Inquiry command, page 0x80."
 | 
						|
      ::= { libraryEntry 10 }
 | 
						|
    
 | 
						|
    libraryDrvCnt OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Number of drives contained in this library."
 | 
						|
      ::= { libraryEntry 11 }
 | 
						|
    
 | 
						|
    librarySlotCnt OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Number of cartridge slots contained in this library"
 | 
						|
      ::= { libraryEntry 12 }
 | 
						|
    
 | 
						|
    libraryImpExpCnt OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Number of import/export elements (mail slots) contained in this library"
 | 
						|
      ::= { libraryEntry 13 }
 | 
						|
    
 | 
						|
    libraryTranspCnt OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Number of transport elements (robots) contained in this library."
 | 
						|
      ::= { libraryEntry 14 }
 | 
						|
    
 | 
						|
    libraryMoves OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Total number of move operations done by this library."
 | 
						|
      ::= { libraryEntry 15 }
 | 
						|
    
 | 
						|
    librarySlotFetchRetries OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "Total number of slot fetch retries by this library."
 | 
						|
      ::= { libraryEntry 16 }
 | 
						|
    
 | 
						|
    librarySlotStowRetries OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "Total number of slot stow retries by this library."
 | 
						|
      ::= { libraryEntry 17 }
 | 
						|
    
 | 
						|
    libraryDrvFetchRetries OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "Total number of drive fetch retries by this library."
 | 
						|
      ::= { libraryEntry 18 }
 | 
						|
    
 | 
						|
    libraryDrvStowRetries OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "Total number of drive stow retries by this library."
 | 
						|
      ::= { libraryEntry 19 }
 | 
						|
    
 | 
						|
    libraryDoorState OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
        {
 | 
						|
        unknown(1),
 | 
						|
        open(2),
 | 
						|
        closed(3),
 | 
						|
        locked(4)
 | 
						|
        }
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "State of the door(s) pf this library. The interpretation of this value is vendor specific."
 | 
						|
      ::= { libraryEntry 20 }
 | 
						|
    
 | 
						|
    libraryImpExpState OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
        {
 | 
						|
        unknown(1),
 | 
						|
        open(2),
 | 
						|
        closed(3),
 | 
						|
        locked(4)
 | 
						|
        }
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "State of the Import/Export element(s) of this library. The interpretation of this value is vendor specific."
 | 
						|
      ::= { libraryEntry 21 }   
 | 
						|
      
 | 
						|
    libraryFaultFSC OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "The library Fault error code."
 | 
						|
      ::= { libraryEntry 22 }
 | 
						|
 | 
						|
    libraryFaultSev OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER   
 | 
						|
        {
 | 
						|
        informational(1),
 | 
						|
        minor(2),
 | 
						|
        major(3),
 | 
						|
        critical(4)
 | 
						|
        }      
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "The library Fault severity."
 | 
						|
      ::= { libraryEntry 23 }
 | 
						|
                               
 | 
						|
    libraryFaultDescr OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS optional
 | 
						|
      DESCRIPTION
 | 
						|
        "The library Fault description."
 | 
						|
      ::= { libraryEntry 24 }      
 | 
						|
    
 | 
						|
    driveTable OBJECT-TYPE
 | 
						|
      SYNTAX SEQUENCE OF DriveEntry
 | 
						|
      ACCESS not-accessible
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "A table of all tape drive devices in this library."
 | 
						|
      ::= { shadowPhysical 2 }
 | 
						|
    
 | 
						|
    driveEntry OBJECT-TYPE
 | 
						|
      SYNTAX DriveEntry
 | 
						|
      ACCESS not-accessible
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Entry in the device Table. Each entry contains
 | 
						|
        an index (driveEntryId), and the values associated 
 | 
						|
        with the device."
 | 
						|
      INDEX { driveEntryId }
 | 
						|
      ::= { driveTable 1 }
 | 
						|
    
 | 
						|
    DriveEntry ::=
 | 
						|
      SEQUENCE { 
 | 
						|
        driveEntryId
 | 
						|
          INTEGER,
 | 
						|
        driveState
 | 
						|
          INTEGER,
 | 
						|
        driveTimeStamp
 | 
						|
          INTEGER,
 | 
						|
        driveType
 | 
						|
          INTEGER,
 | 
						|
        driveScsiId
 | 
						|
          INTEGER,
 | 
						|
        driveScsiLun
 | 
						|
          INTEGER,
 | 
						|
        driveVendorId
 | 
						|
          DisplayString,
 | 
						|
        driveProductId
 | 
						|
          DisplayString,
 | 
						|
        driveFwlevel
 | 
						|
          DisplayString,
 | 
						|
        driveSerNum
 | 
						|
          DisplayString,
 | 
						|
        driveLibrarySN
 | 
						|
          DisplayString,
 | 
						|
        driveTpHrs
 | 
						|
          INTEGER,
 | 
						|
        driveClean
 | 
						|
          INTEGER,
 | 
						|
        driveLoads
 | 
						|
          INTEGER,
 | 
						|
        driveSoftWrtErrors
 | 
						|
          INTEGER,
 | 
						|
        driveHardWrtErrors
 | 
						|
          INTEGER,
 | 
						|
        driveSoftReadErrors
 | 
						|
          INTEGER,
 | 
						|
        driveHardReadErrors
 | 
						|
          INTEGER
 | 
						|
       }
 | 
						|
 | 
						|
    driveEntryId OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER (1..512)
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Table entry index value. Each unique physical device has a unique driveEntryId."
 | 
						|
      ::= { driveEntry 1 }
 | 
						|
    
 | 
						|
    driveState OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device SCSI State."
 | 
						|
      ::= { driveEntry 2 }
 | 
						|
    
 | 
						|
    driveTimeStamp OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Universal time in sec since UTC 1/1/70 when the device data was last updated."
 | 
						|
      ::= { driveEntry 3 }
 | 
						|
    
 | 
						|
    driveType OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "SCSI device type."
 | 
						|
      ::= { driveEntry 4 }
 | 
						|
    
 | 
						|
    driveScsiId OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "SCSI ID of the device."
 | 
						|
      ::= { driveEntry 5 }
 | 
						|
    
 | 
						|
    driveScsiLun OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "SCSI Lun of the device."
 | 
						|
      ::= { driveEntry 6 }
 | 
						|
 | 
						|
    driveVendorId OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device Vendor as would be reported in a SCSI Inquiry command."
 | 
						|
      ::= { driveEntry 7 }
 | 
						|
    
 | 
						|
    driveProductId OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device Model as would be reported in a SCSI Inquiry command."
 | 
						|
      ::= { driveEntry 8 }
 | 
						|
    
 | 
						|
    driveFwlevel OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device firmware level as would be reported in a SCSI Inquiry command."
 | 
						|
      ::= { driveEntry 9 }
 | 
						|
    
 | 
						|
    driveSerNum OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Device serial number as reported in SCSI Inquiry command, page 0x80."
 | 
						|
      ::= { driveEntry 10 }
 | 
						|
       
 | 
						|
    driveLibrarySN OBJECT-TYPE
 | 
						|
      SYNTAX DisplayString
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Serial Number of the library that this drive is in as reported in SCSI Inquiry command, page 0x80, for the media mover device."
 | 
						|
      ::= { driveEntry 11 }
 | 
						|
    
 | 
						|
    driveTpHrs OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Total drive motion hours of this device."
 | 
						|
      ::= { driveEntry 12 }
 | 
						|
    
 | 
						|
    driveClean OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Cleaning State of the device. The interpretation of this value is vendor specific."
 | 
						|
      ::= { driveEntry 13 }
 | 
						|
    
 | 
						|
    driveLoads OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Total cartridge loads for the drive."
 | 
						|
      ::= { driveEntry 14 }
 | 
						|
    
 | 
						|
    driveSoftWrtErrors OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Recovered soft write error count for current cartridge"
 | 
						|
      ::= { driveEntry 15 }
 | 
						|
    
 | 
						|
    driveHardWrtErrors OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Hard write error count for current cartridge"
 | 
						|
      ::= { driveEntry 16 }
 | 
						|
    
 | 
						|
    driveSoftReadErrors OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Recovered soft read error count for current cartridge"
 | 
						|
      ::= { driveEntry 17 }
 | 
						|
    
 | 
						|
    driveHardReadErrors OBJECT-TYPE
 | 
						|
      SYNTAX INTEGER
 | 
						|
      ACCESS read-only
 | 
						|
      STATUS mandatory
 | 
						|
      DESCRIPTION
 | 
						|
        "Hard read error count for current cartridge"
 | 
						|
      ::= { driveEntry 18 }
 | 
						|
 
 | 
						|
--
 | 
						|
-- Trap definitions
 | 
						|
--
 | 
						|
    shadowEvent OBJECT IDENTIFIER ::= { shadow 4 }
 | 
						|
    
 | 
						|
	eventStatusChange NOTIFICATION-TYPE
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION 
 | 
						|
			"The library status has changed."
 | 
						|
		--#TYPE "Library Status Change"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) status has changed from %s to %s"
 | 
						|
		--#ARGUMENTS {0,1,2,3}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 1}
 | 
						|
 | 
						|
	eventDoorOpen NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"The library door has been opened."
 | 
						|
		--#TYPE "Library Door Opened"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) door has been opened."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 2}
 | 
						|
	
 | 
						|
	eventMailSlotAccessed NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"The library mail slot has been accessed."
 | 
						|
		--#TYPE "Library Mail Slot Accessed"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) mail slot has been accessed."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 3}
 | 
						|
	
 | 
						|
	eventFaultPosted NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"The library has posted a hard fault."
 | 
						|
		--#TYPE "Library Hard Fault Posted"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) has posted a hard fault. Severity = %s, FSC = %s, Description = %s."
 | 
						|
		--#ARGUMENTS {0,1,2,3,4}
 | 
						|
		--#SEVERITY CRITICAL
 | 
						|
		::= {shadowEvent 4}
 | 
						|
	
 | 
						|
	eventRequestDriveClean NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"One of the library tape drives has requested a cleaning cycle to ensure continued
 | 
						|
            data reliability."
 | 
						|
		--#TYPE "Tape Drive Requested Cleaning"
 | 
						|
		--#SUMMARY "One of the library %s (Serial Number %s) tape drives has requested a cleaning cycle."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 5}
 | 
						|
	
 | 
						|
	eventDriveError NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"One of the library tape drives has reported an error condition."
 | 
						|
		--#TYPE "Tape Drive Reported Error"
 | 
						|
		--#SUMMARY "One of the library %s (Serial Number %s) tape drives has reported an error condition."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY MAJOR
 | 
						|
		::= {shadowEvent 6}
 | 
						|
	
 | 
						|
	eventLoaderRetriesExcessive NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"The library has detected excessive loader retries."
 | 
						|
		--#TYPE "Excessive loader retries"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) has detected excessive loader retries."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY MINOR
 | 
						|
		::= {shadowEvent 7}
 | 
						|
	
 | 
						|
	eventLoaderOK NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"The library has reverted to normal operation."
 | 
						|
		--#TYPE "Library reverted to normal operation"
 | 
						|
		--#SUMMARY "The library %s (Serial Number %s) has reverted to normal operation."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 8}    
 | 
						|
	
 | 
						|
	eventLoaderPasswordChange NOTIFICATION-TYPE
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"Library password has changed"
 | 
						|
		--#TYPE "Password Change"
 | 
						|
		--#SUMMARY "An account password in library %s (Serial Number %s) has changed."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 9}   
 | 
						|
	
 | 
						|
 	eventLoaderConfigChange NOTIFICATION-TYPE    
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"A logical library configuration setting has been changed."
 | 
						|
		--#TYPE "Configuration Change"
 | 
						|
		--#SUMMARY "A logical library configuration setting has been changed."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 10}   
 | 
						|
 | 
						|
	eventBrowserLogin NOTIFICATION-TYPE    
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"Someone logged in via Web Browser."
 | 
						|
		--#TYPE "Web Access"
 | 
						|
		--#SUMMARY "Someone logged in via Web Browser."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 11}   
 | 
						|
	
 | 
						|
	eventBrowserLogout NOTIFICATION-TYPE    
 | 
						|
		STATUS  current
 | 
						|
		DESCRIPTION
 | 
						|
			"Someone logged from Web Browser."
 | 
						|
		--#TYPE "Web Access"
 | 
						|
		--#SUMMARY "Someone logged from Web Browser."
 | 
						|
		--#ARGUMENTS {0,1}
 | 
						|
		--#SEVERITY INFORMATIONAL
 | 
						|
		::= {shadowEvent 12}
 | 
						|
 | 
						|
		
 | 
						|
	--OLD Style Trap definitions      
 | 
						|
	
 | 
						|
	eventStatusChange TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum, 
 | 
						|
        			  shadowStatusLastGlobalStatus,
 | 
						|
        			  shadowStatusGlobalStatus	 }		
 | 
						|
    	DESCRIPTION 
 | 
						|
			"The library status has changed."	
 | 
						|
		::=  1
 | 
						|
		
 | 
						|
	eventDoorOpen  TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }		
 | 
						|
		DESCRIPTION
 | 
						|
			"The library door has been opened."		
 | 
						|
		::= 2
 | 
						|
	
 | 
						|
	eventMailSlotAccessed TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
   		DESCRIPTION
 | 
						|
			"The library mail slot has been accessed."	
 | 
						|
		::= 3
 | 
						|
	
 | 
						|
	eventFaultPosted TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum,
 | 
						|
        			  libraryFaultSev,
 | 
						|
        			  libraryFaultFSC,
 | 
						|
        			  libraryFaultDescr	 }
 | 
						|
   		DESCRIPTION
 | 
						|
			"The library has posted a hard fault."		
 | 
						|
		::= 4
 | 
						|
			
 | 
						|
	eventRequestDriveClean TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"One of the library tape drives has requested a cleaning cycle to ensure continued
 | 
						|
            data reliability."		
 | 
						|
        ::= 5
 | 
						|
	
 | 
						|
	eventDriveError TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"One of the library tape drives has reported an error condition."
 | 
						|
		::= 6
 | 
						|
	
 | 
						|
	eventLoaderRetriesExcessive TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"The library has detected excessive loader retries."
 | 
						|
		::= 7
 | 
						|
	
 | 
						|
	eventLoaderOK TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"The library has reverted to normal operation."
 | 
						|
		::= 8  
 | 
						|
	
 | 
						|
	eventLoaderPasswordChange TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"An account password in the library has changed."
 | 
						|
		::= 9	 	
 | 
						|
		
 | 
						|
 	eventLoaderConfigChange TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"A logical library configuration setting has been changed."
 | 
						|
		::= 10
 | 
						|
 | 
						|
	eventBrowserLogin TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"Someone logged in via Web Browser"
 | 
						|
		::= 11
 | 
						|
 | 
						|
  	eventBrowserLogout TRAP-TYPE    
 | 
						|
    	ENTERPRISE  shadowEvent
 | 
						|
        VARIABLES   { libraryProductId,
 | 
						|
        			  librarySerNum	 }
 | 
						|
		DESCRIPTION
 | 
						|
			"Someone logged out from Web Browser"
 | 
						|
		::= 12
 | 
						|
			
 | 
						|
  END
 | 
						|
 | 
						|
--
 | 
						|