| NSCRTV-EPON-ALARM-MGM-MIB DEFINITIONS ::= BEGIN
 | ||
| 
 | ||
| IMPORTS
 | ||
|     MODULE-IDENTITY, OBJECT-TYPE,Counter32, Unsigned32, TimeTicks
 | ||
|         FROM SNMPv2-SMI
 | ||
|     DateAndTime, MacAddress, TimeStamp, RowStatus, TruthValue, DisplayString, TEXTUAL-CONVENTION
 | ||
|         FROM SNMPv2-TC
 | ||
|     EponDeviceIndex, EponCardIndex, EponPortIndex, EponAlarmCode, EponAlarmInstance, EponSeverityType,
 | ||
|     AutoNegotiationTechAbility, TAddress, EponStats15MinRecordType, EponStats24HourRecordType, EponStatsThresholdType
 | ||
| 		FROM NSCRTV-EPONEOC-EPON-MIB
 | ||
|     eponAlarmTree, eponTrapObjectGroup, eponAlarmObjGroup, eponManagementObjGroup
 | ||
|         FROM NSCRTV-EPONEOC-EPON-MIB;
 | ||
| 
 | ||
| --------------------------------------------------------------------------------
 | ||
| --  AlarmManagementObjects[¸æ¾¯¹ÜÀíÏî](1.3.6.1.4.1.17409.2.2.11)
 | ||
| -------------------------------------------------------------------------------- 
 | ||
|        
 | ||
|     eponNotifications OBJECT IDENTIFIER ::= { eponTrapObjectGroup 1 }
 | ||
|     
 | ||
|     eponAlarmNotification NOTIFICATION-TYPE
 | ||
|       OBJECTS { eponTrapSequenceNumber, eponTrapOccurTime, eponTrapCode, eponTrapInstance, 
 | ||
|       eponTrapSeverity, eponTrapCorrelationId, eponTrapAdditionalText
 | ||
|          }
 | ||
|       STATUS current
 | ||
|       DESCRIPTION 
 | ||
|         "Alarm TRAP definition"
 | ||
|       ::= { eponNotifications 1 }
 | ||
| 
 | ||
|     eponEventNotification NOTIFICATION-TYPE
 | ||
|       OBJECTS { eponTrapSequenceNumber, eponTrapOccurTime, eponTrapCode, eponTrapInstance, 
 | ||
|       eponTrapAdditionalText
 | ||
|          }
 | ||
|       STATUS current
 | ||
|       DESCRIPTION 
 | ||
|         "Event TRAP definition"
 | ||
|       ::= { eponNotifications 2 }
 | ||
| 
 | ||
|     eponTrapObjects OBJECT IDENTIFIER ::= { eponTrapObjectGroup 2 }
 | ||
|     
 | ||
|     eponTrapInstance OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmInstance
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm instance, indicates the detailed managed object, which
 | ||
|         detects faults.
 | ||
|         "
 | ||
|       ::= { eponTrapObjects 1 }
 | ||
|     
 | ||
|     eponTrapCorrelationId OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "The unique sequence number for the alarm to be cleared, for alarm clearing. 
 | ||
|         Set to 0 for alarm reporting"
 | ||
|       ::= { eponTrapObjects 2 }
 | ||
|     
 | ||
|     eponTrapAdditionalText OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING ( SIZE (0..256) )
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Additional info to the alarm, for further desciption of the
 | ||
|         alarm. The format of it shall be related to each kind alarm
 | ||
|         defined in alarm reference table"
 | ||
|       ::= { eponTrapObjects 3 }
 | ||
|     
 | ||
|     eponTrapCode OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmCode
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯´úÂ룬¼û¸½Â¼C"
 | ||
|       ::= { eponTrapObjects 4 }
 | ||
|     
 | ||
|     eponTrapSeverity OBJECT-TYPE
 | ||
|       SYNTAX EponSeverityType
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯ÑÏÖØ³Ì¶È¡£"
 | ||
|       ::= { eponTrapObjects 5 }
 | ||
|     
 | ||
|     eponTrapOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯²úÉúʱ¼ä¡£"
 | ||
|       ::= { eponTrapObjects 6 }
 | ||
|     
 | ||
|     eponTrapSequenceNumber OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS accessible-for-notify
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         A unique sequence number for each trap generated by node. The sequence 
 | ||
|         number shall be reset to 1 when node restarts.         
 | ||
|         The alarm sequence number shall be independent of the event sequence 
 | ||
|         number. Each shall be self-governed.
 | ||
| 
 | ||
|         --------------------------------------------------------------------------------            
 | ||
|         The sequence ID of alarm shall be assigned from the order of transmitting 
 | ||
|         trap to the NMS, instead of the order of alarm occurance. Therefore the NMS 
 | ||
|         will receive the continuous sequence ID.
 | ||
|             
 | ||
|         1.  When device is in active/standby mode, sequence ID shall be synchronized 
 | ||
|           between active and standby control module.
 | ||
|         2.  When control module switchover takes place, the current sequence ID shall 
 | ||
|           keep the synchronized value.
 | ||
|         3.  When device restarts, sequence ID shall start from 1.
 | ||
|         4.  It shall be increased per alarm trap including both alarm raising and clear.
 | ||
|         5.  Non-zero value shall be used. When reaches the maximum number, it shall 
 | ||
|         roll back to 1.          
 | ||
| 
 | ||
|         --------------------------------------------------------------------------------        
 | ||
|         The sequence ID of event shall be assigned from the order of transmitting 
 | ||
|         trap to the NMS. Therefore the NMS will receive the continuous sequence ID.            
 | ||
|         1.  When device is in active/standby mode, sequence ID shall be synchronized 
 | ||
|           between active and standby control module.
 | ||
|         2.  When control module switchover takes place, the current sequence ID shall 
 | ||
|           keep the synchronized value.
 | ||
|         3.  When device restarts, sequence ID shall start from 1.
 | ||
|         4.  It shall be increased per event trap.
 | ||
|         5.  Non-zero value shall be used. When reaches the maximum number, it shall 
 | ||
|         roll back to 1.        
 | ||
|         "
 | ||
|       ::= { eponTrapObjects 7 }
 | ||
|     
 | ||
|     activeAlarmTable OBJECT-TYPE
 | ||
|       SYNTAX SEQUENCE OF ActiveAlarmEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Active alarm table
 | ||
|         
 | ||
|         The device shall maintain this table, to maintain all outstanding 
 | ||
|         (not cleared) alarms generated by the device, including:
 | ||
|         1. Not hit device local alarm filter. That means had been reported to
 | ||
|            trap receiver (NMS or EMS)
 | ||
|         2. Hit local alarm filter. That means not trap is reported to trap receiver
 | ||
|            for the alarm.
 | ||
|         
 | ||
|         The device shall maintain two numbers:
 | ||
|         1. Alarm sequence number: As described in eponTrapSequenceNumber, it is initially
 | ||
|            set to 1 when device restarts, increases per trap reported to trap receiver,
 | ||
|            and rollover to 1 once it reaches the maximum value. 
 | ||
|            From NMS's view, traps received from a nodes will be consecutive, by identifying 
 | ||
|            the alarm sequence number carried in alarm trap. If breaks, means some trap 
 | ||
|            may be lost, since packet loss between NMS and NE. 
 | ||
|         2. Alarm raising number: This is maintained by NE internally and does not intend for
 | ||
|            being acknowledged by external manage system. It is designed to uniquely indentify
 | ||
|            each alarm raised by NE, excluding duplicates. Once one alarm raised, despite 
 | ||
|            whether it is hit by alarm filter, NE shall assign a raising number to it. So, it
 | ||
|            major functionality is to uniquely identify alarms hit NE local alarm filter, since 
 | ||
|            this kindly alarm will not be reported to NMS, and hence no alarm sequence number
 | ||
|            is assigned to it.
 | ||
|            It is initially  set to 1 when device restarts, increases per alarm generation (
 | ||
|            excluding duplicates), and rollover to 1 once it reaches the maximum value. 
 | ||
|         
 | ||
|         FUNCTION DESCRIPTION OF ACTIVE ALARM TABLE:         
 | ||
|         ALARM RAISING
 | ||
|         ----------------------        
 | ||
|         1. When NE detects one fault and associates to one kind of alarm, it shall check whether
 | ||
|            there is same alarm in active alarm table, which is indexed by alarm code and alarm
 | ||
|            instance. If hits, it means duplicates, update the corresponding entry of the table.
 | ||
|            Otherwise,
 | ||
|         2. The alarm is not a duplicate. Assign an alarm raising number. Check whether the
 | ||
|  alarm hits local alarm filters. If hits, set alarm sequence number to 0.
 | ||
|            Create an entry into active alarm table. Otherwise,
 | ||
|         3. Assign an alarm sequence number to the alarm. Create an entry into active alarm
 | ||
|  table. Report the alarm trap to all trap receivers.
 | ||
|            
 | ||
|         ALARM CLEARING
 | ||
|         ----------------------        
 | ||
|         1. When NE detects one fault is cleared and associates to one kind of alarm, it shall 
 | ||
|            check whether there is corresponding alarm in active alarm table, which is indexed
 | ||
| by alarm code and alarm instance. If no hit, escape this clear event. Upon a hit,
 | ||
| if the alarm sequence number is 0, move the active alarm entry to history alarm
 | ||
| table and update the corresponding fields. At this case, historyAlarmCorrelationId
 | ||
| and historyAlarmSeqNum will be set to 0.
 | ||
|            Otherwise,
 | ||
|         2. Assign an alarm sequence number to the clear trap. Report the alarm clear trap to 
 | ||
|            all trap receivers. Move the active alarm entry to history alarm table and update 
 | ||
|            the corresponding fields. At this case, activeAlarmSeqNum shall be copied to 
 | ||
|            historyAlarmCorrelationId, and historyAlarmSeqNum shall be set to the new alarm
 | ||
|            sequence number for the clear trap.
 | ||
|         
 | ||
|         ALARM SYNCHRONIZATION BETWEEN NE AND NMS
 | ||
|         ---------------------------------------------        
 | ||
|         1. Once NMS finds the alarm sequence number in reported alarm traps is not continuous,
 | ||
|            it will walk active or history alarm table of the NE for the lost seuqence number.
 | ||
|         "
 | ||
|       ::= { eponAlarmObjGroup 1 }
 | ||
|     
 | ||
|     activeAlarmEntry OBJECT-TYPE
 | ||
|       SYNTAX ActiveAlarmEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         ""
 | ||
|       INDEX { activeAlarmSeqNum, activeAlarmRaisingNumber }
 | ||
|       ::= { activeAlarmTable 1 }
 | ||
|     
 | ||
|     ActiveAlarmEntry ::=
 | ||
|       SEQUENCE { 
 | ||
|         activeAlarmSeqNum
 | ||
|           Unsigned32,
 | ||
|         activeAlarmCode
 | ||
|           EponAlarmCode,
 | ||
|         activeAlarmInstance
 | ||
|           EponAlarmInstance,
 | ||
|         activeAlarmSeverity
 | ||
|           EponSeverityType,       
 | ||
|         activeAlarmRaisingNumber
 | ||
|           Unsigned32,
 | ||
|         activeAlarmFirstOccurTime
 | ||
|           DateAndTime,
 | ||
|         activeAlarmLastOccurTime
 | ||
|           DateAndTime,
 | ||
|         activeAlarmRepeats
 | ||
|           Counter32,
 | ||
|         activeAlarmConfirm
 | ||
|           TruthValue,
 | ||
|         activeAlarmAdditionalText
 | ||
|           OCTET STRING  
 | ||
|        }
 | ||
| 
 | ||
|     activeAlarmSeqNum OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm sequence number
 | ||
|         
 | ||
|         The definition refered to the description of activeAlarmTable"
 | ||
|       ::= { activeAlarmEntry 1 }
 | ||
|     
 | ||
|     activeAlarmCode OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmCode
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯´úÂ룬¼û¸½Â¼C
 | ||
|         "
 | ||
|       ::= { activeAlarmEntry 2 }    
 | ||
|     activeAlarmInstance OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmInstance
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm instance, indicates the detailed managed object"
 | ||
|       ::= { activeAlarmEntry 3 }
 | ||
|     
 | ||
|     activeAlarmSeverity OBJECT-TYPE
 | ||
|       SYNTAX EponSeverityType
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯ÑÏÖØ³Ì¶È¡£"     
 | ||
|         ::= { activeAlarmEntry 4 }
 | ||
| 
 | ||
|     activeAlarmRaisingNumber OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm raising number.        
 | ||
|         The definition refered to the description of activeAlarmTable"
 | ||
|       ::= { activeAlarmEntry 5 }
 | ||
|                                    
 | ||
|     activeAlarmFirstOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯³õʼ·¢ÉúµÄʱ¼ä        
 | ||
|         The time stamp when alarm occurs, which triggered to create the 
 | ||
|         active alarm entry."
 | ||
|       ::= { activeAlarmEntry 6 }
 | ||
| 
 | ||
|     activeAlarmLastOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         The time stamp when alarm occurs, where the alarm is duplicated 
 | ||
|         with existed active alarm entry, and it was the latest one. "
 | ||
|       ::= { activeAlarmEntry 7 }
 | ||
|     
 | ||
|     activeAlarmRepeats OBJECT-TYPE
 | ||
|       SYNTAX Counter32
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Number of repeated alarms for this active alarm entry"
 | ||
|       ::= { activeAlarmEntry 8 }
 | ||
|   
 | ||
|     activeAlarmConfirm OBJECT-TYPE
 | ||
|       SYNTAX TruthValue
 | ||
|       MAX-ACCESS read-write
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯È·ÈÏ        
 | ||
|         Node shall not clear an active alarm, upon the confirmation 
 | ||
|         of the active alarm, but just mark an acknowledged status.
 | ||
|         
 | ||
|         An alarm will only be cleared once the clear condition hits."
 | ||
|       ::= { activeAlarmEntry 9 }
 | ||
| 
 | ||
|     activeAlarmAdditionalText OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING (SIZE (0..256))
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Additional info to the alarm, for further desciption of the
 | ||
|         alarm. The format of it shall be related to each kind alarm
 | ||
|         defined in alarm reference table"
 | ||
|       ::= { activeAlarmEntry 10 }
 | ||
| 
 | ||
|     historyAlarmTable OBJECT-TYPE
 | ||
|       SYNTAX SEQUENCE OF HistoryAlarmEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "History alarm table.        
 | ||
|         The device shall maintain this table, to maintain all cleared 
 | ||
|         alarms generated by the device, including:        
 | ||
|         1. Not hit device local alarm filter. That means had been reported to
 | ||
|            trap receiver (NMS or EMS)
 | ||
|         2. Hit local alarm filter. That means not trap is reported to trap receiver
 | ||
|            for the alarm.        
 | ||
|         The number of history alarm enteries in the table could be device-specific.
 | ||
|         However, it is recommended no less than 200 entries.        
 | ||
|         The detailed function definition refers to that given in description of
 | ||
|         activeAlarmTable.
 | ||
|         "
 | ||
|       ::= { eponAlarmObjGroup 2 }
 | ||
|     
 | ||
|     historyAlarmEntry OBJECT-TYPE
 | ||
|       SYNTAX HistoryAlarmEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         ""
 | ||
|       INDEX { historyAlarmSeqNum, historyAlarmRaisingNumber }
 | ||
|       ::= { historyAlarmTable 1 }
 | ||
|     
 | ||
|     HistoryAlarmEntry ::=
 | ||
|       SEQUENCE { 
 | ||
|         historyAlarmSeqNum
 | ||
|           Unsigned32,
 | ||
|         historyAlarmCode
 | ||
|           EponAlarmCode,
 | ||
|         historyAlarmInstance
 | ||
|           EponAlarmInstance,
 | ||
|         historyAlarmSeverity
 | ||
|           EponSeverityType,       
 | ||
|         historyAlarmRaisingNumber
 | ||
|           Unsigned32,
 | ||
|         historyAlarmFirstOccurTime
 | ||
|           DateAndTime,
 | ||
|         historyAlarmLastOccurTime
 | ||
|           DateAndTime,
 | ||
|         historyAlarmRepeats
 | ||
|           Counter32,
 | ||
|         historyAlarmCorrelationId
 | ||
|           Unsigned32,
 | ||
|         historyAlarmAdditionalText
 | ||
|           OCTET STRING,
 | ||
|         historyAlarmClearTime
 | ||
|           DateAndTime 
 | ||
|        }
 | ||
| 
 | ||
|     historyAlarmSeqNum OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm sequence number
 | ||
|         
 | ||
|         The definition refered to the description of historyAlarmTable"
 | ||
|       ::= { historyAlarmEntry 1 }
 | ||
|     
 | ||
|     historyAlarmCode OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmCode
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯´úÂ룬¼û¸½Â¼C
 | ||
|         "
 | ||
|       ::= { historyAlarmEntry 2 }
 | ||
|     
 | ||
|     historyAlarmInstance OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmInstance
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm instance, indicates the detailed managed object"
 | ||
|       ::= { historyAlarmEntry 3 }
 | ||
|     
 | ||
|     historyAlarmSeverity OBJECT-TYPE
 | ||
|       SYNTAX EponSeverityType
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯ÑÏÖØ³Ì¶È¡£"     
 | ||
|         ::= { historyAlarmEntry 4 }
 | ||
| 
 | ||
|     historyAlarmRaisingNumber OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Alarm raising number.        
 | ||
|         The definition refered to the description of historyAlarmTable"
 | ||
|       ::= { historyAlarmEntry 5 }
 | ||
|                                    
 | ||
|     historyAlarmFirstOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ¸æ¾¯³õʼ·¢ÉúµÄʱ¼ä        
 | ||
|         The time stamp when alarm occurs, which triggered to create the 
 | ||
|         history alarm entry."
 | ||
|       ::= { historyAlarmEntry 6 }
 | ||
| 
 | ||
|     historyAlarmLastOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         The time stamp when alarm occurs, where the alarm is duplicated 
 | ||
|         with existed history alarm entry, and it was the latest one. "
 | ||
|       ::= { historyAlarmEntry 7 }
 | ||
|     
 | ||
|     historyAlarmRepeats OBJECT-TYPE
 | ||
|       SYNTAX Counter32
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Number of repeated alarms for this history alarm entry"
 | ||
|       ::= { historyAlarmEntry 8 }
 | ||
|   
 | ||
|     historyAlarmCorrelationId OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "It is the corresponding sequence ID of the alarm that to
 | ||
|         be cleared. "
 | ||
|       ::= { historyAlarmEntry 9 }
 | ||
|     historyAlarmAdditionalText OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING (SIZE (0..256))
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Additional info to the alarm, for further desciption of the
 | ||
|         alarm. The format of it shall be related to each kind alarm
 | ||
|         defined in alarm reference table"
 | ||
|       ::= { historyAlarmEntry 10 }
 | ||
| 
 | ||
|     historyAlarmClearTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Define when the alarm was cleared"
 | ||
|       ::= { historyAlarmEntry 11 }
 | ||
| 
 | ||
|     eventLogTable OBJECT-TYPE
 | ||
|       SYNTAX SEQUENCE OF EventLogEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Event log table.        
 | ||
|         The device shall maintain this table, to maintain all events had
 | ||
|         be reported by the device, including:
 | ||
|         1.  The event table shall be saved in RAM memory and shall be flushed 
 | ||
|           when OLT restarts.
 | ||
|         2.  The event log table shall support no less than 200 entries.  When 
 | ||
|           the event log table is full, the oldest entry in the table shall be 
 | ||
|           removed first. 
 | ||
|         3.  When OLT is configured with control module redundancy, active controller
 | ||
|           shall automatically synchronize the events in event log table  b/w active 
 | ||
|           and standby.
 | ||
|         "
 | ||
|       ::= { eponAlarmObjGroup 3 }
 | ||
|     
 | ||
|     eventLogEntry OBJECT-TYPE
 | ||
|       SYNTAX EventLogEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         ""
 | ||
|       INDEX { eventSeqNum }
 | ||
|       ::= { eventLogTable 1 }
 | ||
|     
 | ||
|     EventLogEntry ::=
 | ||
|       SEQUENCE { 
 | ||
|         eventSeqNum
 | ||
|           Unsigned32,
 | ||
|         eventCode
 | ||
|           EponAlarmCode,
 | ||
|         eventInstance
 | ||
|           EponAlarmInstance,
 | ||
|         eventOccurTime
 | ||
|           DateAndTime,
 | ||
|         eventAdditionalText
 | ||
|           OCTET STRING,
 | ||
|        }
 | ||
| 
 | ||
|     eventSeqNum OBJECT-TYPE
 | ||
|       SYNTAX Unsigned32
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Event sequence number
 | ||
|         
 | ||
|         The definition refered to the description of eponTrapSequenceNumber"
 | ||
|       ::= { eventLogEntry 1 }
 | ||
|     
 | ||
|     eventCode OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmCode
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ʼþ´úÂ룬¼û¸½Â¼C
 | ||
|         "
 | ||
|       ::= { eventLogEntry 2 }
 | ||
|   
 | ||
|     eventInstance OBJECT-TYPE
 | ||
|       SYNTAX EponAlarmInstance
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Event instance, indicates the detailed managed object"
 | ||
|       ::= { eventLogEntry 3 }
 | ||
|                                   
 | ||
|     eventOccurTime OBJECT-TYPE
 | ||
|       SYNTAX DateAndTime
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         The time stamp when event occurs"
 | ||
|       ::= { eventLogEntry 4 }
 | ||
| 
 | ||
|     eventAdditionalText OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING (SIZE (0..256))
 | ||
|       MAX-ACCESS read-only
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "Additional info to the event, for further desciption of the
 | ||
|         event. The format of it shall be related to each kind event
 | ||
|         defined in event reference table"
 | ||
|       ::= { eventLogEntry 5 }
 | ||
|     
 | ||
|     eponManagementAddrTable OBJECT-TYPE
 | ||
|       SYNTAX SEQUENCE OF EponManagementAddrEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "A table of transport addresses to be used in the generation
 | ||
|         of SNMP messages."
 | ||
|       ::= { eponManagementObjGroup 1 }
 | ||
|     
 | ||
|     eponManagementAddrEntry OBJECT-TYPE
 | ||
|       SYNTAX EponManagementAddrEntry
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "A transport address to be used in the generation
 | ||
|         of SNMP operations.        
 | ||
|         Entries in the snmpTargetAddrTable are created and
 | ||
|         deleted using the snmpTargetAddrRowStatus object."
 | ||
|       INDEX { eponManagementAddrName }
 | ||
|       ::= { eponManagementAddrTable 1 }
 | ||
|     
 | ||
|     EponManagementAddrEntry ::=
 | ||
|       SEQUENCE { 
 | ||
|         eponManagementAddrName
 | ||
|           OCTET STRING,
 | ||
|         eponManagementAddrTAddress
 | ||
|           TAddress,
 | ||
|         eponManagementAddrCommunity
 | ||
|           OCTET STRING,
 | ||
|         eponManagementAddrRowStatus
 | ||
|           RowStatus
 | ||
|        }
 | ||
| 
 | ||
|     eponManagementAddrName OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING (SIZE (1..32))
 | ||
|       MAX-ACCESS not-accessible
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         EMSÍø¹Ü½ÚµãµÄÃû×Ö"
 | ||
|       ::= { eponManagementAddrEntry 1 }
 | ||
|     
 | ||
|     eponManagementAddrTAddress OBJECT-TYPE
 | ||
|       SYNTAX TAddress
 | ||
|       MAX-ACCESS read-create
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         Íø¹Ü½ÚµãµÄ´«Êä²ãµØÖ·ºÍTRAP UDP¶Ë¿ÚºÅ¡£"
 | ||
|       ::= { eponManagementAddrEntry 2 }
 | ||
|     
 | ||
|     eponManagementAddrCommunity OBJECT-TYPE
 | ||
|       SYNTAX OCTET STRING (SIZE (0..64) )
 | ||
|       MAX-ACCESS read-create
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         ·¢ËÍTRAPµÄCommunity¡£"
 | ||
|       ::= { eponManagementAddrEntry 3 }
 | ||
|     
 | ||
|     eponManagementAddrRowStatus OBJECT-TYPE
 | ||
|       SYNTAX RowStatus
 | ||
|       MAX-ACCESS read-create
 | ||
|       STATUS current
 | ||
|       DESCRIPTION
 | ||
|         "
 | ||
|         Ôö¼Óɾ³ýÒ»¸öEPON¹ÜÀíµØÖ·¡£"
 | ||
|       ::= { eponManagementAddrEntry 4 }
 | ||
| 
 | ||
| --
 | ||
| -- END of NSCRTV-EPON-ALARM-MGM-MIB
 | ||
| --
 | ||
| 
 | ||
| END
 | 