-- Copyright 2001-2008 Symmetricom Austin
|
||
--
|
||
-- FILENAME: SSU2000.MIB
|
||
-- PRODUCT: SSU2000 COMM Module
|
||
-- DESCRIPTION:
|
||
-- This file contains the Symmetricom-Austin SSU2000 private MIB.
|
||
--
|
||
-- NOTES:
|
||
-- In this private MIB, when we define the syntax in Octet String,
|
||
-- we use the subset of the Type-Length-Value (TLV) format (except
|
||
-- we specified otherwise).
|
||
--
|
||
-- The TLV
|
||
-- TYPE (1 byte): indicates the ASN.1 type, as well as
|
||
-- the class of the type.
|
||
-- LENGTH (1 byte): indicates the length of the actual
|
||
-- value represention
|
||
-- VALUE: represents the value of the ASN.1 type as
|
||
-- a string octets.
|
||
--
|
||
-- The (1 byte) type is defined as
|
||
-- Class [bit 6-7], P/C [bit 5], Tag Number [bit 0-4]
|
||
-- Class:
|
||
-- 00 = Universal
|
||
-- 01 = Application
|
||
-- 10 = Context Specific
|
||
-- 11 = Private
|
||
--
|
||
-- P/C:
|
||
-- 0 = Primitive Encoding
|
||
-- 1 = Constructed encoding
|
||
--
|
||
-- Tag Number:
|
||
-- 1 = Boolean type
|
||
-- 2 = Integer
|
||
-- 4 = Octetstring type
|
||
-- 5 = Null type
|
||
-- 10 = Enumerated type
|
||
--
|
||
-- In our application, the type is Application Class with
|
||
-- Primitive Encoding (0x40).
|
||
--
|
||
--
|
||
--
|
||
-- COMMENTS/CHANGES:
|
||
-- JJW 01/11/2001 - Jay Wang: Created
|
||
-- JJW 06/06/2001 - Fixed StaDiMtie1A/B and StaDiMtie2A/B missing mtie100000 definition
|
||
-- JJW 06/22/2001 - Change setMiFreqAErrLmt/setMiFreqBErrLmt setMiFreqAErrLmt/setMiFreqBErrLmt range to [0..10000000]
|
||
-- JJW 06/22/2001 - added extra definition NA for setDiCSFlt.
|
||
-- JJW 06/22/2001 - changed setMiMtie10xxxEL1/2 and setMiMtie10xxxCL1/2 limits to [0..60000] since defined as 16bits.
|
||
-- JJW 09/26/2001 - Changed the Opaque to OCTET STRING
|
||
-- JJW 10/22/2001 - Removed value "warm(1)" in setCkPLLMode
|
||
-- JJW 10/22/2001 - Put stronger check to make sure mtHisInpLoc and tdHisInpLoc specified with port number
|
||
-- JJW 10/22/2001 - Removed value "ignored" in tpNtfCode which is not used.
|
||
-- JJW 01/25/2002 - Added the Composite Clock Input Module, statusCcInp and setupCcInp
|
||
-- JJW 01/25/2002 - Added sysOpmode field in sys to set subtending or non-subtending mode
|
||
-- JJW 02/19/2002 - Allowed additional pql value 1 and 9 be settable in setGpsProvPql, setDiProvPql, and setCiProvPql fields.
|
||
-- JJW 07/09/2002 - Changed setGpsPdop range from 1-10 to 3-10.
|
||
-- JJW 07/09/2002 - Changed setCcComp comments for 275ft per step intead of 500ft per step.
|
||
-- JJW 07/16/2002 - Added inAdapterPart field in InEntry.
|
||
-- JJW 10/02/2002 - Added staOtPortSta range from 1-5 to 1-6 where 6 is defined as port is squelched.
|
||
-- JJW 10/02/2002 - Added setCoSquelch field in SetCoEntry.
|
||
-- JJW 04/01/2003 - Added RS422 Output Module MIB in setup422Out
|
||
-- JJW 05/01/2003 - Changed the MODULE-IDENTITY to Symmetricom
|
||
-- JJW 06/18/2003 - Added E12048 Output Module MIB in setupE12048Out
|
||
-- JJW 09/23/2003 - Restricted snmpmanIp to Read Only for SNMPv3 (It belongs to Level4 function)
|
||
-- JJW 09/23/2003 - Restricted snmpmanInit to v2 and not apply to v3.
|
||
-- JJW 11/20/2003 - Changed setCkMinTau and setCkMaxTau ranges from (300..10000) to (150..10000)
|
||
-- JJW 01/08/2004 - Added DS1 LRM Module MIB in statusLrm and setupLrm
|
||
-- JJW 02/06/2004 - Added pllflt(6) in staLrmMRefSrc field
|
||
-- JJW 02/06/2004 - Added unknown(4) in staLrmMCtaId field
|
||
-- JJW 03/05/2004 - Added etl1c(10) and etl1d(11) in comLogoff fields.
|
||
-- JJW 03/05/2004 - Added etl1c(10) and etl1d(11) in whoPort fields.
|
||
-- JJW 03/08/2004 - Allowed pql value 1 thru 9 be settable in setGpsProvPql, setDiProvPql, and setCiProvPql fields.
|
||
-- JJW 03/08/2004 - Added sysTl1Format(sys 5)object in sys object.
|
||
-- JJW 03/29/2004 - Added Sine Output Module MIB in setupSineOut
|
||
-- JJW 03/29/2004 - Added Sine Input Module MIB in setupSineInp and statusSineInp
|
||
-- JJW 03/29/2004 - Added Japanese Composite Clock Output Module MIB in setupJccOut
|
||
-- JJW 03/29/2004 - Added Japanese Composite Clock Input Module MIB in setupJccInp and statusJccInp
|
||
-- JJW 07/23/2004 - Added japanese(3)in sysOpmode fields (i.e. Japanese subtending mode).
|
||
-- JJW 10/11/2004 - Changed the stGpsTkChnl from 1..8 to 1..12
|
||
-- JJW 01/12/2005 - added xxxMStatus (module status) fields for all input modules.
|
||
-- JJW 01/14/2005 - Tracker #20460, limited pql value 1 and 9 be settable in setGpsProvPql, setDiProvPql, setCiProvPql, setSineiProvPql, setJcciProvPql fields.
|
||
-- JJW 02/01/2005 - RES #3321, Added/changed snmpman objects and fields for new v3 implementation
|
||
-- renamed snmpmanTable to snmpv2manTable
|
||
-- added initv2 and initv3 fields in snmpmanInit object
|
||
-- added snmpNotification, snmpEnable, snmpv3manTable, snmpv2userTable, snmpv3userTable objects
|
||
-- JJW 02/01/2005 - Added sInterfaces(ssu2000 60) object to specify if various interfaces present or not.
|
||
-- JJW 02/01/2005 - RES #3464, Added E1 LRM Module MIB in statusLrme1 and setupLrme1.
|
||
-- JJW 02/01/2005 - removed statusCdma (mstatus 6) and setupCdma (msetup 6) in the msetup object.
|
||
-- JJW 02/01/2005 - Tracker #20519, added setGpsZeroPhase field in SetGpsEntry.
|
||
-- JJW 02/22/2005 - Tracker #20553, applied "ssu2000 MODULE-IDENTITY" OID with {austron 1 1} instead of {products 1} (note: both are the same OID)
|
||
-- to avoid conflicts within HP Openview with some MIBs from other vendors.
|
||
-- JJW 02/22/2005 - Tracker #20545, removed unnecessary fields in the CC inp module of StaCiEntry, SetCiEntry, and SetCimEntry.
|
||
-- JJW 05/20/2005 - Tracker #20580, added fields setE12048oFrame, setE12048oCrc, setE12048oSsm, setE12048oCrc and setE12048oSsmBit in SetE12048oEntry.
|
||
-- JJW 08/26/2005 - Tracker #21166, added sysAco 'alarm cut off' (sys 7) in sys object.
|
||
-- JJW 02/22/2006 - Version realignment.
|
||
-- JJW 03/28/2006 - Added more description in TModuleCode hex number module definition.
|
||
-- JJW 03/29/2006 - Tracker #21301, Added ntpPrefer (ntp 12) in the ntp object.
|
||
-- JJW 03/30/2006 - Tracker #20656, Added tmLocalOffset (time 2) in the time object and TLocalTimeOffset definition.
|
||
-- JJW 04/25/2006 - Tracker #20639, Added GPS Performance Monitor (MTIE and FREQ)
|
||
-- added staGpsMtie1A, staGpsMtie2A, staGpsMtie1B, staGpsMtie2B, staGpsFreqA, staGpsFreqB to StaGpsEntry object.
|
||
-- added setAlmThGpsInpTable object in (setupGps 2) for MTIE and FREQ setting.
|
||
-- JJW 06/20/2006 - Tracker #21475, Changed the limitis from 1-100k, to 1-10k in setMiOOFErrCnt,setMiOOFClrCnt,setMiBPVErrCnt,
|
||
-- setMiBPVClrCnt, setMiCRCErrCnt,and setMiCRCClrCnt in the DS1/E1 input module.
|
||
-- setCimBPVErrCnt and setCimBPVClrCnt in the CC Input Module
|
||
-- JJW 10/18/2006 - Tracker #22077, Added alarm threshold setting in the Sine Input Module:
|
||
-- added fields in staSineiPql, staSineiMtie1A, staSineiMtie2A, staSineiMtie1B, staSineiMtie2B,
|
||
-- staSineiFreqA, staSineiFreqB in the staSineiEntry.
|
||
-- added a new object table setAlmThSineInpTable in setupSineInp object.
|
||
-- JJW 10/18/2006 - Tracker #21780, Added staGpsPpsSigma and staGps3Sigma in the StaGpsEntry object.
|
||
-- JJW 01/25/2008 - PRD 5.1, Added PackeTime NTP Module Support:
|
||
-- Added statusPtNtp object in mstatus (15),
|
||
-- Added setupPtNtp object in msetup (22),
|
||
-- Added ntpq object in ssu2000 (19),
|
||
-- Added route object in ssu2000 (20),
|
||
-- Added setCkTodTimeout field in the setCkEntry(7)
|
||
-- Added staCkUtc field in the staCkEntry(7)
|
||
-- Added refClkTodsrc field in the ref(7)
|
||
-- Added setGpsTodsrcPriority(14) and setGpsTodsrcCompensation(15) field in the setGpsEntry.
|
||
-- JJW 02/02/2012 - PRD 6.4, Added following support:
|
||
-- Added statusPtPtp object in mstatus (16),
|
||
-- Added setupPtPtp object in msetup (23),
|
||
-- Added ptpclient object in ssu2000 (36),
|
||
-- Added almStatus field in almEntry (9),
|
||
-- Added statusSynce object in mstatus (17),
|
||
-- Added setupSynce object in msetup (24),
|
||
-- Added setPtPtpRmvClient field in setPtPtpEntry (34)
|
||
-- Added setCkFreqTimeout field in the setCkEntry(8)
|
||
-- GGUO 07/08/2012 - PRD GLONASS, Added following support:
|
||
-- Added setGnssCmode field in the setGpsEntry (16),
|
||
-- Added new option for setGpsEngine field in the setGpsEntry(3)
|
||
-- modified stGpsTkChnl from 12 TO 32,
|
||
-- modified stGpsAvChnl from 12 TO 32,
|
||
-- modified setGpsAvg from 10..3600 to 20..3600, and also the method will
|
||
-- make GSP to be 20..3600, and GNSS to be 20..1440
|
||
-- modified setGpsPosel from (0..60)to (0..90)
|
||
-- modified setGpsTimel from (0..60)to (0..90)
|
||
--
|
||
-- CURRENT VERSION:
|
||
-- Part No - 12613127-002-2
|
||
-- 04/16/2001 - A.00
|
||
-- 07/06/2001 - A.01
|
||
-- 01/21/2002 - A.02
|
||
-- 07/17/2002 - B.00 (ECN#: 2167)
|
||
-- 10/22/2002 - C.00 (ECN#: 2241)
|
||
-- 05/15/2003 - D.00 (ECO#: 7735)
|
||
-- 09/09/2003 - E.00 (ECO#: 7825)
|
||
-- 01/14/2004 - F.00 (ECO#: 7946)
|
||
-- 02/06/2004 - F.01 (ECO#: 7969)
|
||
-- 03/05/2004 - F.02 (ECO#: 8021)
|
||
-- 09/03/2004 - G.00 (ECO#: 8139)
|
||
-- 02/01/2005 - G.01 (ECO#: 8302)
|
||
-- 03/25/2005 - H.00 (ECO#: 8369)
|
||
-- 09/29/2005 - J.00 (ECO#: 8483)
|
||
-- 02/22/2006 - K.00 (ECO#: 8600)
|
||
-- 07/06/2006 - L.00 (ECO#: 8762)
|
||
-- 11/03/2006 - L.01 (ECO#: 8936)
|
||
-- 06/10/2008 - M.00 (EC0#: 0190)
|
||
-- 03/08/2012 - N.00 (EC07565)
|
||
-- 08/17/2012 - P.00
|
||
--
|
||
-- +++
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
SSU2000-MIB DEFINITIONS ::= BEGIN
|
||
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
||
OBJECT-IDENTITY,Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
|
||
DisplayString,TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
|
||
austron
|
||
FROM DATUM-MIB;
|
||
|
||
|
||
ssu2000 MODULE-IDENTITY
|
||
-- YYMMDD0000Z the LAST-UPDATED format
|
||
LAST-UPDATED "0801140000Z"
|
||
ORGANIZATION "Symmetricom"
|
||
CONTACT-INFO
|
||
"
|
||
Symmetricom Technical Support
|
||
1-888-367-7966 toll free USA
|
||
1-408-428-7907 worldwide
|
||
Support@symmetricom.com
|
||
"
|
||
DESCRIPTION
|
||
"Private MIB module for management of SSU2000.
|
||
This SSU2000 private MIB supports all existing
|
||
functions of the SSU2000 thus achieving full system
|
||
control via this software interface. All reports,
|
||
queries, autonomous messages, control, provisioning
|
||
and administration (except for Set User ID/password/level,
|
||
Set IP assignments, Reset Connection and SNMP Community
|
||
Settings) will be addressable via SNMP.
|
||
"
|
||
::= { austron 1 1 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PRIVATE MIB, TOP-LEVEL TREE STRUCTURE
|
||
-- **************************************************************
|
||
|
||
inventory OBJECT IDENTIFIER ::= { ssu2000 1 }
|
||
mstatus OBJECT IDENTIFIER ::= { ssu2000 2 }
|
||
msetup OBJECT IDENTIFIER ::= { ssu2000 3 }
|
||
general OBJECT IDENTIFIER ::= { ssu2000 4 }
|
||
event OBJECT IDENTIFIER ::= { ssu2000 5 }
|
||
alarm OBJECT IDENTIFIER ::= { ssu2000 6 }
|
||
ref OBJECT IDENTIFIER ::= { ssu2000 7 }
|
||
phase OBJECT IDENTIFIER ::= { ssu2000 8 }
|
||
freq OBJECT IDENTIFIER ::= { ssu2000 9 }
|
||
ntp OBJECT IDENTIFIER ::= { ssu2000 10 }
|
||
time OBJECT IDENTIFIER ::= { ssu2000 11 }
|
||
pqlTable OBJECT IDENTIFIER ::= { ssu2000 12 }
|
||
ioname OBJECT IDENTIFIER ::= { ssu2000 13 }
|
||
comm OBJECT IDENTIFIER ::= { ssu2000 14 }
|
||
snmpman OBJECT IDENTIFIER ::= { ssu2000 15 }
|
||
sys OBJECT IDENTIFIER ::= { ssu2000 16 }
|
||
users OBJECT IDENTIFIER ::= { ssu2000 17 }
|
||
who OBJECT IDENTIFIER ::= { ssu2000 18 }
|
||
ntpq OBJECT IDENTIFIER ::= { ssu2000 19 }
|
||
route OBJECT IDENTIFIER ::= { ssu2000 20 }
|
||
|
||
mtie OBJECT IDENTIFIER ::= { ssu2000 30 }
|
||
tdev OBJECT IDENTIFIER ::= { ssu2000 31 }
|
||
|
||
-- s1port OBJECT IDENTIFIER ::= { ssu2000 32 }
|
||
-- phaseT1 OBJECT IDENTIFIER ::= { ssu2000 33 }
|
||
-- tie100 OBJECT IDENTIFIER ::= { ssu2000 34 }
|
||
-- mtie100 OBJECT IDENTIFIER ::= { ssu2000 35 }
|
||
ptpclient OBJECT IDENTIFIER ::= { ssu2000 36 }
|
||
|
||
mTrapReq OBJECT IDENTIFIER ::= { ssu2000 50 }
|
||
mTrapObjs OBJECT IDENTIFIER ::= { ssu2000 51 }
|
||
mTraps OBJECT IDENTIFIER ::= { ssu2000 52 }
|
||
|
||
sInterfaces OBJECT IDENTIFIER ::= { ssu2000 60 }
|
||
|
||
|
||
--
|
||
-- status
|
||
--
|
||
statusCom OBJECT IDENTIFIER ::= { mstatus 1 }
|
||
statusClk OBJECT IDENTIFIER ::= { mstatus 2 }
|
||
statusGps OBJECT IDENTIFIER ::= { mstatus 5 }
|
||
statusDs1E1Inp OBJECT IDENTIFIER ::= { mstatus 7 }
|
||
statusCcInp OBJECT IDENTIFIER ::= { mstatus 8 }
|
||
statusOut OBJECT IDENTIFIER ::= { mstatus 10 }
|
||
statusLrm OBJECT IDENTIFIER ::= { mstatus 11 }
|
||
statusSineInp OBJECT IDENTIFIER ::= { mstatus 12 }
|
||
statusJccInp OBJECT IDENTIFIER ::= { mstatus 13 }
|
||
statusLrmE1 OBJECT IDENTIFIER ::= { mstatus 14 }
|
||
statusPtNtp OBJECT IDENTIFIER ::= { mstatus 15 }
|
||
statusPtPtp OBJECT IDENTIFIER ::= { mstatus 16 }
|
||
statusSynce OBJECT IDENTIFIER ::= { mstatus 17 }
|
||
|
||
|
||
--
|
||
-- setup
|
||
--
|
||
setupCom OBJECT IDENTIFIER ::= { msetup 1 }
|
||
setupClk OBJECT IDENTIFIER ::= { msetup 2 }
|
||
setupGps OBJECT IDENTIFIER ::= { msetup 5 }
|
||
setupDs1E1Inp OBJECT IDENTIFIER ::= { msetup 7 }
|
||
setupCcInp OBJECT IDENTIFIER ::= { msetup 8 }
|
||
setupDs1Out OBJECT IDENTIFIER ::= { msetup 10 }
|
||
setupE1Out OBJECT IDENTIFIER ::= { msetup 11 }
|
||
setup2048Out OBJECT IDENTIFIER ::= { msetup 12 }
|
||
setupCCOut OBJECT IDENTIFIER ::= { msetup 13 }
|
||
setup422Out OBJECT IDENTIFIER ::= { msetup 14 }
|
||
setupE12048Out OBJECT IDENTIFIER ::= { msetup 15 }
|
||
setupLrm OBJECT IDENTIFIER ::= { msetup 16 }
|
||
setupSineOut OBJECT IDENTIFIER ::= { msetup 17 }
|
||
setupSineInp OBJECT IDENTIFIER ::= { msetup 18 }
|
||
setupJccOut OBJECT IDENTIFIER ::= { msetup 19 }
|
||
setupJccInp OBJECT IDENTIFIER ::= { msetup 20 }
|
||
setupLrmE1 OBJECT IDENTIFIER ::= { msetup 21 }
|
||
setupPtNtp OBJECT IDENTIFIER ::= { msetup 22 }
|
||
setupPtPtp OBJECT IDENTIFIER ::= { msetup 23 }
|
||
setupSynce OBJECT IDENTIFIER ::= { msetup 24 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 TEXTUAL-CONVENTION DEFINITION
|
||
-- **************************************************************
|
||
|
||
OkValue ::= INTEGER { ok (1), fault (2) }
|
||
OnValue ::= INTEGER { on (1), off (2) }
|
||
YesValue ::= INTEGER { yes (1), no (2) }
|
||
EnaValue ::= INTEGER { ena (1), dis (2) }
|
||
ActiveValue ::= INTEGER { active (1), inactive (2) }
|
||
ValidValue ::= INTEGER { valid (1), invalid (2) }
|
||
TrueValue ::= INTEGER { true (1), false (2) }
|
||
|
||
|
||
-- ******************************************
|
||
-- DEFINED IN RFC2579
|
||
-- ******************************************
|
||
|
||
DateAndTime ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A date-time specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1-2 year* 0..65536
|
||
2 3 month 1..12
|
||
3 4 day 1..31
|
||
4 5 hour 0..23
|
||
5 6 minutes 0..59
|
||
6 7 seconds 0..60
|
||
(use 60 for leap-second)
|
||
7 8 deci-seconds 0..9
|
||
8 9 direction from UTC '+' / '-'
|
||
9 10 hours from UTC* 0..13
|
||
10 11 minutes from UTC 0..59
|
||
|
||
* Notes:
|
||
- the value of year is in network-byte order
|
||
- daylight saving time in New Zealand is +13
|
||
|
||
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
|
||
displayed as:
|
||
|
||
1992-5-26,13:30:15.0,-4:0
|
||
|
||
|
||
Note that if only local time is known, then timezone
|
||
information (fields 8-10) is not present."
|
||
SYNTAX OCTET STRING (SIZE (8 | 11))
|
||
|
||
|
||
-- ******************************************
|
||
-- LOCAL TIME OFFSET DEFINITION
|
||
-- ******************************************
|
||
|
||
TLocalTimeOffset ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a1d:1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A local time offset specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 direction from UTC '+' / '-'
|
||
2 2 hours from UTC* 0..13
|
||
3 3 minutes from UTC 0..59
|
||
|
||
* Notes:
|
||
- the value of year is in network-byte order
|
||
- The hours range is 0..13
|
||
|
||
For example, the -6 local time offset would be
|
||
displayed as: -6:0
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (3))
|
||
|
||
|
||
-- ******************************************
|
||
-- MODULE HEX CODE DEFINITION
|
||
-- ******************************************
|
||
|
||
TModuleCode ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "x"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The module hex code
|
||
1001 Input <20> 3 Port
|
||
1002 Input <20> 1 Port
|
||
1003 Input <20> DS1 3 Port
|
||
1004 Input <20> DS1 1 Port
|
||
1005 Input <20> E1 3 Port
|
||
1006 Input <20> E1 1 Port
|
||
1008 Input <20> GPS
|
||
1010 Input <20> Composite Clock (1 Port)
|
||
1012 Input <20> Japanese CC (1 Port)
|
||
1013 Input <20> Japanese Sine (3 Port)
|
||
2001 Clock <20> Stratum 2E Rubidium
|
||
2002 Clock <20> Stratum 3E
|
||
2003 Clock <20> Type I
|
||
3001 Communication Module
|
||
4001 Output <20> DS1
|
||
4002 Output <20> E1
|
||
4003 Output <20> Composite Clock
|
||
4004 Output <20> 2048 kHz
|
||
4007 Output <20> EIA 422
|
||
4008 Output <20> E1/2048 kHz
|
||
4009 DS1 Line Retiming Module 4 Ports
|
||
400A DS1 Line Retiming Module 2 Ports
|
||
400B Output <20> Japanese CC
|
||
400C Output <20> Japanese Sine
|
||
400D E1 Line Retiming Module 4 Ports
|
||
4021 NTP Blade
|
||
4022 PTP Blade
|
||
5001 Buffer Card
|
||
"
|
||
SYNTAX INTEGER (0..'FFFF'h)
|
||
|
||
|
||
-- ******************************************
|
||
-- SYNC STATUS MESSAGE (SSM) DEFINITION
|
||
-- ******************************************
|
||
|
||
TSsm ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "x"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The ssm hex code"
|
||
SYNTAX INTEGER (0..255)
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- ANTENNA LATITUDE AND LONGITUDE DEFINITION
|
||
-- ******************************************
|
||
|
||
TLatAndLon ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a1d:1d:1d.1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"antenna latitude and longitude specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 +/-180 deg '+' / '-'
|
||
2 2 degree 0..180
|
||
3 3 minute 0..59
|
||
4 4 second 0..59
|
||
5 5 second fraction 0..99
|
||
|
||
+/- dd:mm:ss.ss
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
|
||
|
||
-- ******************************************
|
||
-- ANTENNA HIGHT DEFINITION
|
||
-- ******************************************
|
||
|
||
TAntHeight ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a2d.1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"antenna height specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 +/- '+' / '-'
|
||
2 2-3 meter 0..10000
|
||
3 4 meter fraction 0..99
|
||
|
||
+/- hh.hh
|
||
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (4))
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 INVENTORY GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
inventoryTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF InEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list containing the system inventory of installed hardware and software components contained in the SSU-2000.
|
||
The number of entries is given by the values of inChassis and inSlot.
|
||
"
|
||
::= { inventory 1 }
|
||
|
||
|
||
inEntry OBJECT-TYPE
|
||
SYNTAX InEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Inventory table contains inventory information for all modules installed in the SSU2000 unit.
|
||
System Inventory attributes.
|
||
"
|
||
INDEX { inChassis, inSlot }
|
||
::= { inventoryTable 1 }
|
||
|
||
|
||
InEntry ::=
|
||
SEQUENCE {
|
||
inChassis
|
||
INTEGER,
|
||
inSlot
|
||
INTEGER,
|
||
inModCode
|
||
TModuleCode,
|
||
inName
|
||
DisplayString,
|
||
inSerial
|
||
DisplayString,
|
||
inService
|
||
DateAndTime,
|
||
inHwPart
|
||
DisplayString,
|
||
inHwRev
|
||
DisplayString,
|
||
inHwDate
|
||
DateAndTime,
|
||
inSwPart
|
||
DisplayString,
|
||
inSwRev
|
||
DisplayString,
|
||
inRevision
|
||
DisplayString,
|
||
inShelfDesc
|
||
DisplayString,
|
||
inShelfPart
|
||
DisplayString,
|
||
inInstalled
|
||
YesValue,
|
||
inAction
|
||
INTEGER,
|
||
inAdapterPart
|
||
DisplayString
|
||
}
|
||
|
||
inChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { inEntry 1 }
|
||
|
||
inSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { inEntry 2 }
|
||
|
||
inModCode OBJECT-TYPE
|
||
SYNTAX TModuleCode
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module type is identified with a Hex value.
|
||
"
|
||
::= { inEntry 3 }
|
||
|
||
|
||
inName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module type is identified with a Name.
|
||
"
|
||
::= { inEntry 4 }
|
||
|
||
inSerial OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's serial number.
|
||
"
|
||
::= { inEntry 5 }
|
||
|
||
inService OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's in-service time.
|
||
"
|
||
::= { inEntry 6 }
|
||
|
||
inHwPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's hardware part number.
|
||
"
|
||
::= { inEntry 7 }
|
||
|
||
inHwRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's hardware revision.
|
||
"
|
||
::= { inEntry 8 }
|
||
|
||
inHwDate OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's date of manufacture.
|
||
"
|
||
::= { inEntry 9 }
|
||
|
||
inSwPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's software part number.
|
||
"
|
||
::= { inEntry 10 }
|
||
|
||
inSwRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's main software revision.
|
||
"
|
||
::= { inEntry 11 }
|
||
|
||
inRevision OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..60))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's software and PLD revisions.
|
||
"
|
||
::= { inEntry 12 }
|
||
|
||
inShelfDesc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports shelf type description.
|
||
"
|
||
::= { inEntry 13 }
|
||
|
||
inShelfPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports shelf part number.
|
||
"
|
||
::= { inEntry 14 }
|
||
|
||
inInstalled OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if this module is physically installed in the system or not.
|
||
1 = module is installed.
|
||
2 = module is physically absent, but the configuration data is still there.
|
||
"
|
||
::= { inEntry 15 }
|
||
|
||
inAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2),
|
||
remove(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User Action:
|
||
ENABLE (1), enables the module.
|
||
DISABLE (2), marks a module as inactive to be removed from the system.
|
||
REMOVE (3), if physically absent, the module is removed from the registry.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
When read, it always displayed as 1.
|
||
"
|
||
::= { inEntry 16 }
|
||
|
||
|
||
inAdapterPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Symmetricom input adapter part number.
|
||
Note: If this field is an empty string, it means the input adapter identification is not applicable for this module.
|
||
"
|
||
::= { inEntry 17 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 FEATURE PRESENCE TABLE
|
||
-- **************************************************************
|
||
|
||
inFeatureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF InFeatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SSU-2000 has two optional features, NTP and SNMP.
|
||
The Feature Presence table provides presence of these features.
|
||
"
|
||
::= { inventory 2 }
|
||
|
||
inFeatureEntry OBJECT-TYPE
|
||
SYNTAX InFeatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"inFeatureIndex
|
||
The index to identify the feature
|
||
inFeature
|
||
The setting of the feature
|
||
"
|
||
INDEX { inFeatureIndex }
|
||
::= { inFeatureTable 1 }
|
||
|
||
|
||
InFeatureEntry ::=
|
||
SEQUENCE {
|
||
inFeatureIndex
|
||
INTEGER,
|
||
inFeature
|
||
EnaValue
|
||
}
|
||
|
||
inFeatureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each feature table.
|
||
1 = NTP
|
||
2 = SNMP
|
||
"
|
||
::= { inFeatureEntry 1 }
|
||
|
||
|
||
inFeature OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SSU-2000 feature set:
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { inFeatureEntry 2 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- FUNCTIONAL DESCRIPTION
|
||
-- The module status group provides information on each module
|
||
-- installed in the system. There are status attributes that are
|
||
-- common for all modules in the system and there are module
|
||
-- specific attributes. All of the status attributes are
|
||
-- read-only objects. Descriptions of the specific module
|
||
-- attributes are listed in each Module Status Group for each type
|
||
-- of module.
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
-- FUNCTIONAL DESCRIPTION
|
||
-- The module status group provides information on each module
|
||
-- installed in the system. There are status attributes that are
|
||
-- common for all modules in the system and there are module
|
||
-- specific attributes. All of the status attributes are
|
||
-- read-only objects. Descriptions of the specific module
|
||
-- attributes are listed in each Module Status Group for each type
|
||
-- of module.
|
||
-- Though the Status Information will show alarm status (if a module
|
||
-- is in an alarmed state or not), the detail of all alarm states
|
||
-- is available through the module's alarm object.
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 CLOCK MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staClkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports Clock Module Status, loop mode, tau, and system-level priority quality level (pql).
|
||
"
|
||
::= { statusClk 1 }
|
||
|
||
|
||
staCkEntry OBJECT-TYPE
|
||
SYNTAX StaCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock Status Attributes:
|
||
"
|
||
INDEX { staCkChassis, staCkSlot}
|
||
::= { staClkTable 1 }
|
||
|
||
StaCkEntry ::=
|
||
SEQUENCE {
|
||
staCkChassis
|
||
INTEGER,
|
||
staCkSlot
|
||
INTEGER,
|
||
staCkStatus
|
||
INTEGER,
|
||
staCkPLLMode
|
||
INTEGER,
|
||
staCkTau
|
||
Counter32,
|
||
staCkPql
|
||
INTEGER,
|
||
staCkUtc
|
||
YesValue
|
||
}
|
||
|
||
staCkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { staCkEntry 1 }
|
||
|
||
staCkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This slot number and chassis number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
|
||
"
|
||
::= { staCkEntry 2 }
|
||
|
||
|
||
staCkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
selected(2), -- module is enabled and selected as primary local oscillator
|
||
disable(3), -- module is disabled
|
||
fault(4) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staCkEntry 3 }
|
||
|
||
staCkPLLMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
failed(1),
|
||
warmup(2),
|
||
acquire(3),
|
||
holdover(4),
|
||
lock(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock software Phase Locked Loop (PLL) Mode.
|
||
failed(1), -- pll hardware failure, pll unlocked
|
||
warmup(2), -- local oscillator is initialized and warming up
|
||
acquire(3), -- LO is operating in acquire or fast locked mode
|
||
holdover(4), -- LO is operating in holdover due to lose or reference input
|
||
lock(5) -- LO is operating in normal mode
|
||
"
|
||
::= { staCkEntry 4 }
|
||
|
||
staCkTau OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock tau value.
|
||
The tau is the time constant (in seconds) used by the clock's servo control loop.
|
||
"
|
||
::= { staCkEntry 5 }
|
||
|
||
staCkPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the system Priority Quality Level (PQL).
|
||
The PQL indicates the Stratum Level of the clock.
|
||
Zero indicates an invalid SSM was read.
|
||
"
|
||
::= { staCkEntry 6 }
|
||
|
||
staCkUtc OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock has been TOD synced with GPS or PackeTime..
|
||
"
|
||
::= { staCkEntry 7 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 GPS MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- GPS STATUS TABLE
|
||
-- ******************************************
|
||
|
||
staGpsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS Input Module Status reports the module's current status, input port phase data,
|
||
time status, MTIE threshold status, frequency threshold status, and TIE measurement statistics status.
|
||
"
|
||
::= { statusGps 1 }
|
||
|
||
staGpsEntry OBJECT-TYPE
|
||
SYNTAX StaGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS Status Attributes:
|
||
staGpsChassis
|
||
Identifies which chassis is being addressed
|
||
stGpskSlot
|
||
Identifies which slot is being addressed
|
||
staGpsMStatus
|
||
Reports module status
|
||
staGpsStatus
|
||
Reports gps input port status
|
||
staGpsPhaseA
|
||
Reports phase value versus clock A in nano-seconds.
|
||
staGpsPhaseB
|
||
Reports phase value versus clock B in nano-seconds.
|
||
staGpsUtc
|
||
Reports number tells us whether the GPS module has UTC time or not.
|
||
staGpsMtie1A
|
||
Reports which MTIE limit 1 threshold was exceeded on clock A.
|
||
staGpsMtie2A
|
||
Reports which MTIE limit 2 threshold was exceeded on clock A.
|
||
staGpsMtie1B
|
||
Reports which MTIE limit 1 threshold was exceeded on clock B.
|
||
staGpsMtie2B
|
||
Reports which MTIE limit 2 threshold was exceeded on clock B.
|
||
staGpsFreqA
|
||
Reports input port frequency threshold exceeded on clock A.
|
||
staGpsFreqB
|
||
Reports input port frequency threshold exceeded on clock B.
|
||
staGpsPpsSigma
|
||
Reports sigma (statistical) calculation representing noise variation on the GPS 1PPS
|
||
staGps3Sigma
|
||
Reports 3sigma (statistical) calculation representing noise variation on the GPS 1PPS
|
||
"
|
||
INDEX { staGpsChassis, staGpsSlot}
|
||
::= { staGpsTable 1 }
|
||
|
||
|
||
StaGpsEntry ::=
|
||
SEQUENCE {
|
||
staGpsChassis
|
||
INTEGER,
|
||
staGpsSlot
|
||
INTEGER,
|
||
staGpsStatus
|
||
INTEGER,
|
||
staGpsPhaseA
|
||
INTEGER,
|
||
staGpsPhaseB
|
||
INTEGER,
|
||
staGpsUtc
|
||
YesValue,
|
||
staGpsMStatus
|
||
INTEGER,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staGpsMtie1A
|
||
INTEGER,
|
||
staGpsMtie2A
|
||
INTEGER,
|
||
staGpsMtie1B
|
||
INTEGER,
|
||
staGpsMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staGpsFreqA
|
||
OkValue,
|
||
staGpsFreqB
|
||
OkValue,
|
||
|
||
-- SIGMA Values
|
||
staGpsPpsSigma
|
||
DisplayString,
|
||
|
||
staGps3Sigma
|
||
DisplayString
|
||
}
|
||
|
||
staGpsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { staGpsEntry 1 }
|
||
|
||
staGpsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { staGpsEntry 2 }
|
||
|
||
|
||
staGpsStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS port status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
selected(2), -- module is enabled and selected as input reference
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with faults
|
||
reject(5) -- module is rejected due to antenna failure
|
||
"
|
||
::= { staGpsEntry 3 }
|
||
|
||
staGpsPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staGpsEntry 4 }
|
||
|
||
staGpsPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staGpsEntry 5 }
|
||
|
||
staGpsUtc OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS module has been set to UTC time (or not).
|
||
1 = time is available
|
||
2 = time is not available
|
||
"
|
||
::= { staGpsEntry 6 }
|
||
|
||
staGpsMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS module status.
|
||
ok(1), -- module is enabled and operating normally
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled, but not operational due to faults
|
||
"
|
||
::= { staGpsEntry 7 }
|
||
|
||
staGpsMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded on clock A.
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 8 }
|
||
|
||
staGpsMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded on clock A.
|
||
If ok, it means no error for MTIE limit 2 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 9 }
|
||
|
||
|
||
staGpsMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded on clock B.
|
||
If ok, it means no error for MTIE limit 1 on clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 10 }
|
||
|
||
|
||
staGpsMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded on clock B.
|
||
If ok, it means no error for MTIE limit 2 on clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 11 }
|
||
|
||
|
||
staGpsFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the input port frequency threshold exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 12 }
|
||
|
||
|
||
staGpsFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the input port frequency threshold exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 13 }
|
||
|
||
|
||
staGpsPpsSigma OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current 1 PPS Sigma.
|
||
"
|
||
::= { staGpsEntry 14 }
|
||
|
||
staGps3Sigma OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current 3 Sigma Threshold.
|
||
"
|
||
::= { staGpsEntry 15 }
|
||
|
||
-- ******************************************
|
||
-- GPS ENGINE POSITION TABLE
|
||
-- ******************************************
|
||
|
||
stGpsPosTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsPosEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS attributes that report the status of the GPS engine's position and status
|
||
"
|
||
::= { statusGps 2 }
|
||
|
||
|
||
stGpsPosEntry OBJECT-TYPE
|
||
SYNTAX StGpsPosEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS position attributes:
|
||
stGpsPosChassis
|
||
Identifies which chassis is being addressed
|
||
stGpsPosSlot
|
||
Identifies which slot is being addressed
|
||
stGpsPosValid
|
||
Reports if the GPS position is valid or not.
|
||
stGpsPosLat
|
||
Reports antenna latitude position of the GPS module.
|
||
stGpsPosLon
|
||
Reports antenna longitude position of the GPS module.
|
||
stGpsPosHgt
|
||
Reports antenna height (meter) position of the GPS module.
|
||
stGpsPosAccurate
|
||
Reports antenna position accuracy
|
||
stGpsPosPdop
|
||
Reports PDOP assigns a value of accuracy to the calculated position.
|
||
stGpsPosAvg
|
||
Reports position averaging value indicates how many position values are used to determine position.
|
||
"
|
||
INDEX { stGpsPosChassis, stGpsPosSlot}
|
||
::= { stGpsPosTable 1 }
|
||
|
||
|
||
StGpsPosEntry ::=
|
||
SEQUENCE {
|
||
stGpsPosChassis
|
||
INTEGER,
|
||
stGpsPosSlot
|
||
INTEGER,
|
||
stGpsPosValid
|
||
ValidValue,
|
||
stGpsPosLat
|
||
TLatAndLon,
|
||
stGpsPosLon
|
||
TLatAndLon,
|
||
stGpsPosHgt
|
||
TAntHeight,
|
||
stGpsPosAccurate
|
||
INTEGER,
|
||
stGpsPosPdop
|
||
INTEGER,
|
||
stGpsPosAvg
|
||
INTEGER
|
||
}
|
||
|
||
stGpsPosChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsPosEntry 1 }
|
||
|
||
stGpsPosSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsPosEntry 2 }
|
||
|
||
stGpsPosValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the GPS position is valid or not.
|
||
|
||
1 = valid
|
||
2 = invalid
|
||
"
|
||
::= { stGpsPosEntry 3 }
|
||
|
||
stGpsPosLat OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna latitude position of the GPS module.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The latitude is +/- 90 deg.
|
||
"
|
||
::= { stGpsPosEntry 4 }
|
||
|
||
stGpsPosLon OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna longitude position of the GPS module.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The longitude is +/- 180 deg.
|
||
"
|
||
::= { stGpsPosEntry 5 }
|
||
|
||
stGpsPosHgt OBJECT-TYPE
|
||
SYNTAX TAntHeight
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna height (meter) position of the GPS module.
|
||
|
||
The format is +hh.hh or -hh.hh
|
||
The height is +/- 10000.0 meters.
|
||
"
|
||
::= { stGpsPosEntry 6 }
|
||
|
||
stGpsPosAccurate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
approx (1),
|
||
d2 (2),
|
||
d3 (3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna position accuracy
|
||
APPROX - position is not accurate
|
||
D2 - position is accurate, 2D, height is not valid
|
||
D3 - position is accurate, 3D, height is valid
|
||
"
|
||
::= { stGpsPosEntry 7 }
|
||
|
||
stGpsPosPdop OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PDOP indicates position precision as an integer representation of value in tenths.
|
||
For example, the value 19 means 1.9 pdop.
|
||
if zero, it means invalid.
|
||
"
|
||
::= { stGpsPosEntry 8 }
|
||
|
||
stGpsPosAvg OBJECT-TYPE
|
||
SYNTAX INTEGER (0..3600)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite position averaging value.
|
||
If zero, the satellite position is user entered.
|
||
"
|
||
::= { stGpsPosEntry 9 }
|
||
|
||
|
||
-- ******************************************
|
||
-- GPS AVAILABILITY TABLE
|
||
-- ******************************************
|
||
|
||
stGpsAvailTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsAvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS satellite availability, reports the location of visible satellites.
|
||
"
|
||
::= { statusGps 3 }
|
||
|
||
|
||
stGpsAvEntry OBJECT-TYPE
|
||
SYNTAX StGpsAvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS Availability attributes:
|
||
"
|
||
INDEX { stGpsAvChassis, stGpsAvSlot, stGpsAvChnl}
|
||
::= { stGpsAvailTable 1 }
|
||
|
||
|
||
StGpsAvEntry ::=
|
||
SEQUENCE {
|
||
stGpsAvChassis
|
||
INTEGER,
|
||
stGpsAvSlot
|
||
INTEGER,
|
||
stGpsAvChnl
|
||
INTEGER,
|
||
stGpsAvPNCode
|
||
INTEGER,
|
||
stGpsAvElevation
|
||
INTEGER,
|
||
stGpsAvAzimuth
|
||
INTEGER,
|
||
stGpsAvHealthy
|
||
YesValue
|
||
}
|
||
|
||
|
||
stGpsAvChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsAvEntry 1 }
|
||
|
||
stGpsAvSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsAvEntry 2 }
|
||
|
||
stGpsAvChnl OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite channel number.
|
||
"
|
||
::= { stGpsAvEntry 3 }
|
||
|
||
stGpsAvPNCode OBJECT-TYPE
|
||
SYNTAX INTEGER (0..99)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite PN code.
|
||
"
|
||
::= { stGpsAvEntry 4 }
|
||
|
||
stGpsAvElevation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated elevation (in degrees) of the satellite.
|
||
"
|
||
::= { stGpsAvEntry 5 }
|
||
|
||
stGpsAvAzimuth OBJECT-TYPE
|
||
SYNTAX INTEGER (0..360)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated Azimuth (in degrees) of the satellite.
|
||
"
|
||
::= { stGpsAvEntry 6 }
|
||
|
||
stGpsAvHealthy OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current health of the satellite.
|
||
|
||
1 = healthy
|
||
2 = unhealthy
|
||
"
|
||
::= { stGpsAvEntry 7 }
|
||
|
||
|
||
-- ******************************************
|
||
-- GPS TRACKING TABLE
|
||
-- ******************************************
|
||
|
||
stGpsTrackTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsTkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS satellites being tracked show with visibility, signal strength, & health information.
|
||
"
|
||
::= { statusGps 5 }
|
||
|
||
|
||
stGpsTkEntry OBJECT-TYPE
|
||
SYNTAX StGpsTkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A entry GPS attributes.
|
||
"
|
||
INDEX { stGpsTkChassis, stGpsTkSlot, stGpsTkChnl}
|
||
::= { stGpsTrackTable 1 }
|
||
|
||
|
||
StGpsTkEntry ::=
|
||
SEQUENCE {
|
||
stGpsTkChassis
|
||
INTEGER,
|
||
stGpsTkSlot
|
||
INTEGER,
|
||
stGpsTkChnl
|
||
INTEGER,
|
||
stGpsTkSv
|
||
INTEGER,
|
||
stGpsTkSnr
|
||
INTEGER,
|
||
stGpsTkStatus
|
||
INTEGER
|
||
}
|
||
|
||
stGpsTkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsTkEntry 1 }
|
||
|
||
stGpsTkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsTkEntry 2 }
|
||
|
||
stGpsTkChnl OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite channel number.
|
||
"
|
||
::= { stGpsTkEntry 3 }
|
||
|
||
stGpsTkSv OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..32)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite vehicle number being tracked.
|
||
if zero, it is invalid
|
||
"
|
||
::= { stGpsTkEntry 4 }
|
||
|
||
stGpsTkSnr OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports signal-to-noise ration number being reported
|
||
if zero, it is invalid
|
||
"
|
||
::= { stGpsTkEntry 5 }
|
||
|
||
stGpsTkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
src (1), -- search
|
||
acq (2), -- acquire
|
||
agc (3), -- automatic gain control
|
||
frq (4), -- frequency locking
|
||
cod (5), -- code locking
|
||
msg (6), -- messaging
|
||
tim (7), -- setting time
|
||
eph (8), -- retriving ephemeris data
|
||
ok (9) -- satellite being used in the timing solution
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports tracking status.
|
||
src (1), -- search
|
||
acq (2), -- acquire
|
||
agc (3), -- automatic gain control
|
||
frq (4), -- frequency locking
|
||
cod (5), -- code locking
|
||
msg (6), -- messaging
|
||
tim (7), -- setting time
|
||
eph (8), -- retriving ephemeris data
|
||
ok (9) -- satellite being used in the timing solution
|
||
"
|
||
::= { stGpsTkEntry 6 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1/E1 Input status entries.
|
||
"
|
||
::= { statusDs1E1Inp 2 }
|
||
|
||
|
||
staDiEntry OBJECT-TYPE
|
||
SYNTAX StaDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staDiChassis, staDiSlot, staDiPort }
|
||
::= { staDs1E1InpTable 1 }
|
||
|
||
StaDiEntry ::=
|
||
SEQUENCE {
|
||
staDiChassis
|
||
INTEGER,
|
||
staDiSlot
|
||
INTEGER,
|
||
staDiPort
|
||
INTEGER,
|
||
|
||
staDiStatus
|
||
INTEGER,
|
||
staDiPhaseA
|
||
INTEGER,
|
||
staDiPhaseB
|
||
INTEGER,
|
||
staDiPql
|
||
INTEGER,
|
||
staDiPqlRcv
|
||
YesValue,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staDiLOS
|
||
OkValue,
|
||
staDiAIS
|
||
OkValue,
|
||
staDiOOF
|
||
OkValue,
|
||
staDiBPV
|
||
OkValue,
|
||
staDiCRC
|
||
OkValue,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staDiMtie1A
|
||
INTEGER,
|
||
staDiMtie2A
|
||
INTEGER,
|
||
staDiMtie1B
|
||
INTEGER,
|
||
staDiMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staDiFreqA
|
||
OkValue,
|
||
staDiFreqB
|
||
OkValue,
|
||
|
||
-- INPUT SIGNAL ERROR/CLEAR COUNT
|
||
staLOSErCnt
|
||
Counter32,
|
||
staLOSClCnt
|
||
Counter32,
|
||
staAISErCnt
|
||
Counter32,
|
||
staAISClCnt
|
||
Counter32,
|
||
staOOFErCnt
|
||
Counter32,
|
||
staOOFClCnt
|
||
Counter32,
|
||
staBPVErCnt
|
||
Counter32,
|
||
staBPVClCnt
|
||
Counter32,
|
||
staCRCErCnt
|
||
Counter32,
|
||
staCRCClCnt
|
||
Counter32,
|
||
|
||
-- Module Status
|
||
staDiMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staDiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staDiEntry 1 }
|
||
|
||
staDiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staDiEntry 2 }
|
||
|
||
|
||
staDiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staDiEntry 3 }
|
||
|
||
|
||
staDiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staDiEntry 4 }
|
||
|
||
staDiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staDiEntry 5 }
|
||
|
||
staDiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staDiEntry 6 }
|
||
|
||
staDiPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port Priority Quality Level (PQL).
|
||
The PQL is the current stratum level (read or provisioned) being reported by the port.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { staDiEntry 7 }
|
||
|
||
staDiPqlRcv OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports receiving Sync Status Message (SSM) for the input port state.
|
||
|
||
1 = enabled
|
||
2 = disabled
|
||
"
|
||
::= { staDiEntry 8 }
|
||
|
||
|
||
staDiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staDiEntry 9 }
|
||
|
||
staDiAIS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has AIS fault.
|
||
"
|
||
::= { staDiEntry 10 }
|
||
|
||
staDiOOF OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has OOF fault.
|
||
"
|
||
::= { staDiEntry 11 }
|
||
|
||
|
||
staDiBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staDiEntry 12 }
|
||
|
||
|
||
staDiCRC OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC fault.
|
||
"
|
||
::= { staDiEntry 13 }
|
||
|
||
|
||
staDiMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 14 }
|
||
|
||
staDiMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 15 }
|
||
|
||
|
||
staDiMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded verus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 1 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 16 }
|
||
|
||
|
||
staDiMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 17 }
|
||
|
||
|
||
staDiFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 18 }
|
||
|
||
|
||
staDiFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 19 }
|
||
|
||
|
||
staLOSErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS error count.
|
||
"
|
||
::= { staDiEntry 20 }
|
||
|
||
|
||
staLOSClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS clear count.
|
||
"
|
||
::= { staDiEntry 21 }
|
||
|
||
|
||
staAISErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port AIS error count.
|
||
"
|
||
::= { staDiEntry 22 }
|
||
|
||
|
||
staAISClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port AIS clear count.
|
||
"
|
||
::= { staDiEntry 23 }
|
||
|
||
|
||
staOOFErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port OOF error count.
|
||
"
|
||
::= { staDiEntry 24 }
|
||
|
||
|
||
staOOFClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port OOF clear count.
|
||
"
|
||
::= { staDiEntry 25 }
|
||
|
||
|
||
staBPVErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV error count.
|
||
"
|
||
::= { staDiEntry 26 }
|
||
|
||
|
||
staBPVClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV clear count.
|
||
"
|
||
::= { staDiEntry 27 }
|
||
|
||
|
||
staCRCErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC error count.
|
||
"
|
||
::= { staDiEntry 28 }
|
||
|
||
|
||
staCRCClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC clear count.
|
||
"
|
||
::= { staDiEntry 29 }
|
||
|
||
|
||
staDiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staDiEntry 30 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMPOSITE CLOCK INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock Input status information.
|
||
"
|
||
::= { statusCcInp 2 }
|
||
|
||
|
||
staCiEntry OBJECT-TYPE
|
||
SYNTAX StaCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staCiChassis, staCiSlot, staCiPort }
|
||
::= { staCcInpTable 1 }
|
||
|
||
StaCiEntry ::=
|
||
SEQUENCE {
|
||
staCiChassis
|
||
INTEGER,
|
||
staCiSlot
|
||
INTEGER,
|
||
staCiPort
|
||
INTEGER,
|
||
|
||
staCiStatus
|
||
INTEGER,
|
||
staCiPhaseA
|
||
INTEGER,
|
||
staCiPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staCiLOS
|
||
OkValue,
|
||
staCiBPV
|
||
OkValue,
|
||
|
||
-- INPUT SIGNAL ERROR/CLEAR COUNT
|
||
staCiLOSErCnt
|
||
Counter32,
|
||
staCiLOSClCnt
|
||
Counter32,
|
||
staCiBPVErCnt
|
||
Counter32,
|
||
staCiBPVClCnt
|
||
Counter32,
|
||
|
||
-- Module Status
|
||
staCiMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staCiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staCiEntry 1 }
|
||
|
||
staCiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staCiEntry 2 }
|
||
|
||
|
||
staCiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staCiEntry 3 }
|
||
|
||
|
||
staCiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staCiEntry 4 }
|
||
|
||
staCiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staCiEntry 5 }
|
||
|
||
staCiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staCiEntry 6 }
|
||
|
||
staCiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staCiEntry 9 }
|
||
|
||
staCiBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staCiEntry 12 }
|
||
|
||
staCiLOSErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS error count.
|
||
"
|
||
::= { staCiEntry 14 }
|
||
|
||
|
||
staCiLOSClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS clear count.
|
||
"
|
||
::= { staCiEntry 15 }
|
||
|
||
staCiBPVErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV error count.
|
||
"
|
||
::= { staCiEntry 20 }
|
||
|
||
|
||
staCiBPVClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV clear count.
|
||
"
|
||
::= { staCiEntry 21 }
|
||
|
||
staCiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staCiEntry 24 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SINE INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine Input status information.
|
||
"
|
||
::= { statusSineInp 2 }
|
||
|
||
|
||
staSineiEntry OBJECT-TYPE
|
||
SYNTAX StaSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staSineiChassis, staSineiSlot, staSineiPort }
|
||
::= { staSineInpTable 1 }
|
||
|
||
StaSineiEntry ::=
|
||
SEQUENCE {
|
||
staSineiChassis
|
||
INTEGER,
|
||
staSineiSlot
|
||
INTEGER,
|
||
staSineiPort
|
||
INTEGER,
|
||
|
||
staSineiStatus
|
||
INTEGER,
|
||
staSineiPhaseA
|
||
INTEGER,
|
||
staSineiPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staSineiLOS
|
||
OkValue,
|
||
|
||
-- Module Status
|
||
staSineiMStatus
|
||
INTEGER,
|
||
|
||
staSineiPql
|
||
INTEGER,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staSineiMtie1A
|
||
INTEGER,
|
||
staSineiMtie2A
|
||
INTEGER,
|
||
staSineiMtie1B
|
||
INTEGER,
|
||
staSineiMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staSineiFreqA
|
||
OkValue,
|
||
staSineiFreqB
|
||
OkValue
|
||
}
|
||
|
||
staSineiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staSineiEntry 1 }
|
||
|
||
staSineiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSineiEntry 2 }
|
||
|
||
|
||
staSineiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSineiEntry 3 }
|
||
|
||
|
||
staSineiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staSineiEntry 4 }
|
||
|
||
staSineiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staSineiEntry 5 }
|
||
|
||
staSineiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staSineiEntry 6 }
|
||
|
||
staSineiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staSineiEntry 7 }
|
||
|
||
staSineiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staSineiEntry 8 }
|
||
|
||
staSineiPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port Priority Quality Level (PQL).
|
||
The PQL is the current stratum level (read or provisioned) being reported by the port.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { staSineiEntry 9 }
|
||
|
||
staSineiMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 10 }
|
||
|
||
staSineiMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 11 }
|
||
|
||
|
||
staSineiMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded verus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 1 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 12 }
|
||
|
||
|
||
staSineiMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 13 }
|
||
|
||
|
||
staSineiFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 14 }
|
||
|
||
|
||
staSineiFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 15 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 JAPANESE COMPOSITE CLOCK INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staJccInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock Input status information.
|
||
"
|
||
::= { statusJccInp 2 }
|
||
|
||
|
||
staJcciEntry OBJECT-TYPE
|
||
SYNTAX StaJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staCiChassis, staCiSlot, staCiPort }
|
||
::= { staJccInpTable 1 }
|
||
|
||
StaJcciEntry ::=
|
||
SEQUENCE {
|
||
staJcciChassis
|
||
INTEGER,
|
||
staJcciSlot
|
||
INTEGER,
|
||
staJcciPort
|
||
INTEGER,
|
||
|
||
staJcciStatus
|
||
INTEGER,
|
||
staJcciPhaseA
|
||
INTEGER,
|
||
staJcciPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staJcciLOS
|
||
OkValue,
|
||
staJcciBPV
|
||
OkValue,
|
||
staJcci400Hz
|
||
OnValue,
|
||
|
||
-- Module Status
|
||
staJcciMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staJcciChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staJcciEntry 1 }
|
||
|
||
staJcciSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staJcciEntry 2 }
|
||
|
||
|
||
staJcciPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staJcciEntry 3 }
|
||
|
||
|
||
staJcciStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staJcciEntry 4 }
|
||
|
||
staJcciPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staJcciEntry 5 }
|
||
|
||
staJcciPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staJcciEntry 6 }
|
||
|
||
staJcciLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staJcciEntry 7 }
|
||
|
||
staJcciBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staJcciEntry 8 }
|
||
|
||
staJcci400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has 400Hz Sync Signal or not.
|
||
"
|
||
::= { staJcciEntry 9 }
|
||
|
||
staJcciMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staJcciEntry 10 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 OUTPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staOutTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaOtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of Generic Output status information.
|
||
"
|
||
::= { statusOut 2 }
|
||
|
||
|
||
staOtEntry OBJECT-TYPE
|
||
SYNTAX StaOtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Output port status attributes.
|
||
"
|
||
INDEX { staOtChassis, staOtSlot}
|
||
::= { staOutTable 1 }
|
||
|
||
StaOtEntry ::=
|
||
SEQUENCE {
|
||
staOtChassis
|
||
INTEGER,
|
||
staOtSlot
|
||
INTEGER,
|
||
staOtStatus
|
||
INTEGER,
|
||
staOtClkSel
|
||
INTEGER,
|
||
staOtClka
|
||
ActiveValue,
|
||
staOtClkb
|
||
ActiveValue,
|
||
staOtClkc
|
||
ActiveValue,
|
||
staOtClkd
|
||
ActiveValue,
|
||
staOtRednt
|
||
INTEGER,
|
||
staOtPql
|
||
INTEGER,
|
||
staOtPortSta
|
||
OCTET STRING
|
||
}
|
||
|
||
staOtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staOtEntry 1 }
|
||
|
||
staOtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staOtEntry 2 }
|
||
|
||
|
||
staOtStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports output port status.
|
||
ok(1), -- modlule is enabled & operating without faults
|
||
disable(3), -- module is diabled
|
||
fault(4) -- module is enabled & operating with fault(s)
|
||
reject(5) -- module type is mismatched with redundant module
|
||
"
|
||
::= { staOtEntry 3 }
|
||
|
||
staOtClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staOtEntry 4 }
|
||
|
||
staOtClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staOtEntry 5 }
|
||
|
||
staOtClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staOtEntry 6 }
|
||
|
||
staOtClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staOtEntry 7 }
|
||
|
||
staOtClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staOtEntry 8 }
|
||
|
||
|
||
staOtRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the output module redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staOtEntry 9 }
|
||
|
||
staOtPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Priority Quality Level (PQL) being generated.
|
||
If zero, it is invalid or Not Applicable.
|
||
"
|
||
::= { staOtEntry 10 }
|
||
|
||
staOtPortSta OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the status for ports 1-20.
|
||
1st digit represents port 1, 20th digit represents port 20
|
||
1 = ok
|
||
2 = not used
|
||
3 = internal port fault
|
||
4 = external port fault
|
||
5 = fault
|
||
6 = squelch
|
||
"
|
||
::= { staOtEntry 11 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1 LRM MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
staLrmMTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrmMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM module status information.
|
||
"
|
||
::= { statusLrm 2 }
|
||
|
||
|
||
staLrmMEntry OBJECT-TYPE
|
||
SYNTAX StaLrmMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"DS1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrmMChassis, staLrmMSlot}
|
||
::= { staLrmMTable 1 }
|
||
|
||
StaLrmMEntry ::=
|
||
SEQUENCE {
|
||
staLrmMChassis
|
||
INTEGER,
|
||
staLrmMSlot
|
||
INTEGER,
|
||
staLrmMStatus
|
||
INTEGER,
|
||
staLrmMRefSrc
|
||
INTEGER,
|
||
staLrmMCtaId
|
||
INTEGER
|
||
}
|
||
|
||
staLrmMChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrmMEntry 1 }
|
||
|
||
staLrmMSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmMEntry 2 }
|
||
|
||
staLrmMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the LRM module state.
|
||
enable(1), -- module is enabled
|
||
disable(2), -- module is disabled
|
||
"
|
||
::= { staLrmMEntry 3 }
|
||
|
||
staLrmMRefSrc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5),
|
||
pllflt(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output and status.
|
||
clka(1), -- clock A is selected
|
||
clkb(2), -- clock B is selected
|
||
clkc(3), -- clock C is selected
|
||
clkd(4), -- clock D is selected
|
||
none(5), -- no clock is selected
|
||
pllflt(6) -- clock selected, but module's clock PLL is unlocked
|
||
"
|
||
::= { staLrmMEntry 4 }
|
||
|
||
staLrmMCtaId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dual(1),
|
||
quad(2),
|
||
none(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if CTA is installed or not, if installed it reports which type, 2 ports or quad (4) ports.
|
||
If not installed, none is shown.
|
||
If id is not recognized, unknown is shown.
|
||
"
|
||
::= { staLrmMEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1 LRM PORT STATUS GROUP
|
||
-- **************************************************************
|
||
staLrmPTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM port status information.
|
||
"
|
||
::= { statusLrm 3 }
|
||
|
||
|
||
staLrmPEntry OBJECT-TYPE
|
||
SYNTAX StaLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"DS1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrmPChassis, staLrmPSlot, staLrmPPort}
|
||
::= { staLrmPTable 1 }
|
||
|
||
StaLrmPEntry ::=
|
||
SEQUENCE {
|
||
staLrmPChassis
|
||
INTEGER,
|
||
staLrmPSlot
|
||
INTEGER,
|
||
staLrmPPort
|
||
INTEGER,
|
||
staLrmPStatus
|
||
INTEGER,
|
||
staLrmPFrame
|
||
INTEGER,
|
||
staLrmPLos
|
||
OkValue,
|
||
staLrmPAis
|
||
OkValue,
|
||
staLrmPLof
|
||
OkValue,
|
||
staLrmPBpv
|
||
OkValue,
|
||
staLrmPSlip
|
||
OkValue,
|
||
staLrmPSlips
|
||
Counter32,
|
||
staLrmPLosSide2
|
||
OkValue,
|
||
staLrmPBpvTestTime
|
||
Counter32,
|
||
staLrmPBpv60SRate
|
||
DisplayString,
|
||
staLrmPBpv24HRate
|
||
DisplayString,
|
||
staLrmPBpvErrSecs
|
||
Counter32,
|
||
staLrmPBpvSevErrSecs
|
||
Counter32,
|
||
staLrmPBpvSevErrRatio
|
||
DisplayString
|
||
}
|
||
|
||
staLrmPChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrmPEntry 1 }
|
||
|
||
staLrmPSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmPEntry 2 }
|
||
|
||
staLrmPPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmPEntry 3 }
|
||
|
||
staLrmPStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port status.
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
"
|
||
::= { staLrmPEntry 4 }
|
||
|
||
staLrmPFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
d4(1), -- D4 signal
|
||
esf(2), -- ESF signal
|
||
none(3) -- indicate Loss Of Frame
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port frame status.
|
||
d4(1), -- D4 signal
|
||
esf(2), -- ESF signal
|
||
none(3) -- indicate Loss Of Frame
|
||
"
|
||
::= { staLrmPEntry 5 }
|
||
|
||
staLrmPLos OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS status.
|
||
"
|
||
::= { staLrmPEntry 6 }
|
||
|
||
staLrmPAis OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port AIS status.
|
||
"
|
||
::= { staLrmPEntry 7 }
|
||
|
||
staLrmPLof OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOF status.
|
||
"
|
||
::= { staLrmPEntry 8 }
|
||
|
||
staLrmPBpv OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port BPV status.
|
||
"
|
||
::= { staLrmPEntry 9 }
|
||
|
||
staLrmPSlip OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port SLIP status.
|
||
If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
|
||
"
|
||
::= { staLrmPEntry 10 }
|
||
|
||
staLrmPSlips OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port slip counts.
|
||
"
|
||
::= { staLrmPEntry 11 }
|
||
|
||
staLrmPLosSide2 OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS on SIDE2 status.
|
||
"
|
||
::= { staLrmPEntry 12 }
|
||
|
||
staLrmPBpvTestTime OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) the BPV has been under tested.
|
||
"
|
||
::= { staLrmPEntry 13 }
|
||
|
||
staLrmPBpv60SRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 60-second window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 14 }
|
||
|
||
staLrmPBpv24HRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 86400-second (24 hours) window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 15 }
|
||
|
||
staLrmPBpvErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Errored Seconds.
|
||
"
|
||
::= { staLrmPEntry 16 }
|
||
|
||
staLrmPBpvSevErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Severely Errored Seconds.
|
||
"
|
||
::= { staLrmPEntry 17 }
|
||
|
||
staLrmPBpvSevErrRatio OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Severely Error Ratio.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 18 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 E1 LRM MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
staLrme1MTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrme1MEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM port status information.
|
||
"
|
||
::= { statusLrmE1 2 }
|
||
|
||
|
||
staLrme1MEntry OBJECT-TYPE
|
||
SYNTAX StaLrme1MEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrme1MChassis, staLrme1MSlot}
|
||
::= { staLrme1MTable 1 }
|
||
|
||
StaLrme1MEntry ::=
|
||
SEQUENCE {
|
||
staLrme1MChassis
|
||
INTEGER,
|
||
staLrme1MSlot
|
||
INTEGER,
|
||
staLrme1MStatus
|
||
INTEGER,
|
||
staLrme1MRefSrc
|
||
INTEGER,
|
||
staLrme1MCtaId
|
||
INTEGER
|
||
}
|
||
|
||
staLrme1MChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrme1MEntry 1 }
|
||
|
||
staLrme1MSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1MEntry 2 }
|
||
|
||
staLrme1MStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the LRM module state.
|
||
enable(1), -- module is enabled
|
||
disable(2), -- module is disabled
|
||
"
|
||
::= { staLrme1MEntry 3 }
|
||
|
||
staLrme1MRefSrc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5),
|
||
pllflt(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output and status.
|
||
clka(1), -- clock A is selected
|
||
clkb(2), -- clock B is selected
|
||
clkc(3), -- clock C is selected
|
||
clkd(4), -- clock D is selected
|
||
none(5), -- no clock is selected
|
||
pllflt(6) -- clock selected, but module's clock PLL is unlocked
|
||
"
|
||
::= { staLrme1MEntry 4 }
|
||
|
||
staLrme1MCtaId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dual(1),
|
||
quad(2),
|
||
none(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if CTA is installed or not.
|
||
If installed it reports which type, 2 ports or quad (4) ports.
|
||
If not installed, none is shown.
|
||
If id is not recognized, unknown is shown.
|
||
"
|
||
::= { staLrme1MEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 E1 LRM PORT STATUS GROUP
|
||
-- **************************************************************
|
||
staLrme1PTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM port status information.
|
||
"
|
||
::= { statusLrmE1 3 }
|
||
|
||
|
||
staLrme1PEntry OBJECT-TYPE
|
||
SYNTAX StaLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrme1PChassis, staLrme1PSlot, staLrme1PPort}
|
||
::= { staLrme1PTable 1 }
|
||
|
||
StaLrme1PEntry ::=
|
||
SEQUENCE {
|
||
staLrme1PChassis
|
||
INTEGER,
|
||
staLrme1PSlot
|
||
INTEGER,
|
||
staLrme1PPort
|
||
INTEGER,
|
||
staLrme1PStatus
|
||
INTEGER,
|
||
staLrme1PFrame
|
||
OnValue,
|
||
staLrme1PLos
|
||
OkValue,
|
||
staLrme1PAis
|
||
OkValue,
|
||
staLrme1PLof
|
||
OkValue,
|
||
staLrme1PBpv
|
||
OkValue,
|
||
staLrme1PSlip
|
||
OkValue,
|
||
staLrme1PSlips
|
||
Counter32,
|
||
staLrme1PLosSide2
|
||
OkValue,
|
||
staLrme1PBpv60SRate
|
||
DisplayString,
|
||
staLrme1PBpv24HRate
|
||
DisplayString,
|
||
staLrme1PBpvErrSecs
|
||
Counter32,
|
||
staLrme1PBpvSevErrSecs
|
||
Counter32,
|
||
staLrme1PBpvSevErrRatio
|
||
DisplayString
|
||
}
|
||
|
||
staLrme1PChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrme1PEntry 1 }
|
||
|
||
staLrme1PSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1PEntry 2 }
|
||
|
||
staLrme1PPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1PEntry 3 }
|
||
|
||
staLrme1PStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port status.
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
"
|
||
::= { staLrme1PEntry 4 }
|
||
|
||
staLrme1PFrame OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port frame status.
|
||
cas(1), -- CAS signal
|
||
ccs(2), -- CCS signal
|
||
none(3) -- indicate Loss Of Frame
|
||
"
|
||
::= { staLrme1PEntry 5 }
|
||
|
||
staLrme1PLos OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS status.
|
||
"
|
||
::= { staLrme1PEntry 6 }
|
||
|
||
staLrme1PAis OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port AIS status.
|
||
"
|
||
::= { staLrme1PEntry 7 }
|
||
|
||
staLrme1PLof OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOF status.
|
||
"
|
||
::= { staLrme1PEntry 8 }
|
||
|
||
staLrme1PBpv OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port BPV status.
|
||
"
|
||
::= { staLrme1PEntry 9 }
|
||
|
||
staLrme1PSlip OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port SLIP status.
|
||
If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
|
||
"
|
||
::= { staLrme1PEntry 10 }
|
||
|
||
staLrme1PSlips OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port slip counts.
|
||
"
|
||
::= { staLrme1PEntry 11 }
|
||
|
||
staLrme1PLosSide2 OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS on SIDE2 status.
|
||
"
|
||
::= { staLrme1PEntry 12 }
|
||
|
||
staLrme1PBpv60SRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) the BPV has been under tested.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 13 }
|
||
|
||
staLrme1PBpv24HRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 86400-second (24 hours) window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 14 }
|
||
|
||
staLrme1PBpvErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Errored Seconds.
|
||
"
|
||
::= { staLrme1PEntry 15 }
|
||
|
||
staLrme1PBpvSevErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Severely Errored Seconds.
|
||
"
|
||
::= { staLrme1PEntry 16 }
|
||
|
||
staLrme1PBpvSevErrRatio OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Severely Error Ratio.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 17 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME NTP MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staPtNtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP status information.
|
||
"
|
||
::= { statusPtNtp 1 }
|
||
|
||
|
||
staPtNtpEntry OBJECT-TYPE
|
||
SYNTAX StaPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP status attributes.
|
||
"
|
||
INDEX { staPtNtpChassis, staPtNtpSlot}
|
||
::= { staPtNtpTable 1 }
|
||
|
||
StaPtNtpEntry ::=
|
||
SEQUENCE {
|
||
staPtNtpChassis
|
||
INTEGER,
|
||
staPtNtpSlot
|
||
INTEGER,
|
||
staPtNtpStatus
|
||
INTEGER,
|
||
staPtNtpClkSel
|
||
INTEGER,
|
||
staPtNtpClka
|
||
ActiveValue,
|
||
staPtNtpClkb
|
||
ActiveValue,
|
||
staPtNtpClkc
|
||
ActiveValue,
|
||
staPtNtpClkd
|
||
ActiveValue,
|
||
staPtNtpRednt
|
||
INTEGER,
|
||
staPtNtpModState
|
||
INTEGER,
|
||
staPtNtpPAState
|
||
INTEGER,
|
||
staPtNtpPBState
|
||
INTEGER,
|
||
staPtNtpTod
|
||
OnValue,
|
||
staPtNtpCommit
|
||
INTEGER
|
||
}
|
||
|
||
staPtNtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtNtpEntry 1 }
|
||
|
||
staPtNtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtNtpEntry 2 }
|
||
|
||
|
||
staPtNtpStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The PackeTime NTP module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with fault(s)
|
||
reject(5) -- module type between redundant modules do not agree
|
||
"
|
||
::= { staPtNtpEntry 3 }
|
||
|
||
staPtNtpClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock reference is selected to generate the output reference.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staPtNtpEntry 4 }
|
||
|
||
staPtNtpClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staPtNtpEntry 5 }
|
||
|
||
staPtNtpClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staPtNtpEntry 6 }
|
||
|
||
staPtNtpClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staPtNtpEntry 7 }
|
||
|
||
staPtNtpClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staPtNtpEntry 8 }
|
||
|
||
staPtNtpRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staPtNtpEntry 9 }
|
||
|
||
staPtNtpModState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If the module is in redundant pair and selected, it shall return active.
|
||
stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby).
|
||
fault(3), --If the module disabled, it will return fault.
|
||
stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 10 }
|
||
|
||
staPtNtpPAState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 11 }
|
||
|
||
staPtNtpPBState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 12 }
|
||
|
||
staPtNtpTod OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the NTP Time of Day is valid or invalid.
|
||
"
|
||
::= { staPtNtpEntry 13 }
|
||
|
||
staPtNtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
done(1),
|
||
prog(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Commit command status.
|
||
1 = done
|
||
2 = in progress
|
||
"
|
||
::= { staPtNtpEntry 14 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SETUP GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setCmId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (7))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The system identifier, the value is always 'SSU2000'.
|
||
"
|
||
::= { setupCom 1 }
|
||
|
||
setCmInfo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Symmetricom contact information.
|
||
This displays the Symmetricom address, phone, and fax numbers.
|
||
"
|
||
::= { setupCom 2 }
|
||
|
||
setCmVer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..100))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports Communication module's software version
|
||
"
|
||
::= { setupCom 3 }
|
||
|
||
setCmName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the user assigned name for the SSU2000.
|
||
|
||
Note: Use caution when changing this, TL1 sessions use the unit name as the target id (tid).
|
||
"
|
||
::= { setupCom 4 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 CLOCK MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setClkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of clock status and setting information.
|
||
"
|
||
::= { setupClk 1 }
|
||
|
||
|
||
setCkEntry OBJECT-TYPE
|
||
SYNTAX SetCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock status and setting attributes.
|
||
"
|
||
INDEX { setCkChassis, setCkSlot}
|
||
::= { setClkTable 1 }
|
||
|
||
SetCkEntry ::=
|
||
SEQUENCE {
|
||
setCkChassis
|
||
INTEGER,
|
||
setCkSlot
|
||
INTEGER,
|
||
setCkWarmup
|
||
INTEGER,
|
||
setCkMinTau
|
||
INTEGER,
|
||
setCkMaxTau
|
||
INTEGER,
|
||
setCkPLLMode
|
||
INTEGER,
|
||
setCkTodTimeout
|
||
INTEGER,
|
||
setCkFreqTimeout
|
||
INTEGER
|
||
}
|
||
|
||
setCkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setCkEntry 1 }
|
||
|
||
setCkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This slot number and chassis number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
|
||
"
|
||
::= { setCkEntry 2 }
|
||
|
||
setCkWarmup OBJECT-TYPE
|
||
SYNTAX INTEGER (900..3600)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock warmup time in seconds.
|
||
"
|
||
::= { setCkEntry 3 }
|
||
|
||
|
||
setCkMinTau OBJECT-TYPE
|
||
SYNTAX INTEGER (150..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock minimum tau.
|
||
The mintau is the starting time constant value during Locked mode.
|
||
"
|
||
::= { setCkEntry 4 }
|
||
|
||
setCkMaxTau OBJECT-TYPE
|
||
SYNTAX INTEGER (150..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock max tau.
|
||
The maxtau is the final time constant value during Locked mode.
|
||
"
|
||
::= { setCkEntry 5 }
|
||
|
||
|
||
|
||
setCkPLLMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
acq(2),
|
||
lock(3),
|
||
hold(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock operating mode to ACQ/ LOCK/ HOLD.
|
||
Note: When WRITE is to request Clock to change its operating mode, but
|
||
when READ, it returns status of current operating mode. If current is
|
||
operating mode is Warmup, it will return as HOLD.
|
||
"
|
||
::= { setCkEntry 6 }
|
||
|
||
setCkTodTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TODSRC Timeout.
|
||
The TOD Traceability Timeout shall allow the system to operate without a valid
|
||
TOD source for some amount of time before indicating the ToD source is invalid.
|
||
The timer shall have a user settable range from 60 to 10000 minutes,
|
||
with a default value of 1440.
|
||
"
|
||
::= { setCkEntry 7 }
|
||
|
||
setCkFreqTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Frequency Timeout.
|
||
The Frequency Traceability Timeout shall allow the system to operate without a valid
|
||
input reference for some amount of time before indicating the frequency source is invalid.
|
||
The timer shall have a user settable range from 60 to 10000 minutes,
|
||
with a default value of 1440.
|
||
"
|
||
::= { setCkEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 GPS MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setGpsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS status and setting information.
|
||
"
|
||
::= { setupGps 1 }
|
||
|
||
setGpsEntry OBJECT-TYPE
|
||
SYNTAX SetGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS status and setting attributes.
|
||
"
|
||
INDEX { setGpsChassis, setGpsSlot}
|
||
::= { setGpsTable 1 }
|
||
|
||
|
||
SetGpsEntry ::=
|
||
SEQUENCE {
|
||
setGpsChassis
|
||
INTEGER,
|
||
setGpsSlot
|
||
INTEGER,
|
||
setGpsEngine
|
||
INTEGER,
|
||
setGpsProvPql
|
||
INTEGER,
|
||
setGpsPriority
|
||
INTEGER,
|
||
setGpsPdop
|
||
INTEGER,
|
||
setGpsPosel
|
||
INTEGER,
|
||
setGpsTimel
|
||
INTEGER,
|
||
setGpsAvg
|
||
INTEGER,
|
||
setGpsLat
|
||
TLatAndLon,
|
||
setGpsLon
|
||
TLatAndLon,
|
||
setGpsHgt
|
||
TAntHeight,
|
||
setGpsZeroPhase
|
||
INTEGER,
|
||
setGpsTodsrcPriority
|
||
INTEGER,
|
||
setGpsTodsrcCompensation
|
||
INTEGER,
|
||
setGnssConsMode
|
||
INTEGER
|
||
}
|
||
|
||
setGpsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setGpsEntry 1 }
|
||
|
||
setGpsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { setGpsEntry 2 }
|
||
|
||
setGpsEngine OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
na(1),
|
||
unknown(2),
|
||
mot(3),
|
||
nvs(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS engine manufacturer.
|
||
na(1), -- not available
|
||
unknown(2), -- unknown
|
||
mot(3) -- motorola (or motorola compatible)
|
||
nvs(4) -- NVS engine (or GLONASS compatible)
|
||
"
|
||
::= { setGpsEntry 3 }
|
||
|
||
setGpsProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL) value.
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setGpsEntry 4 }
|
||
|
||
|
||
setGpsPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
The 0 is for monitor-only mode.
|
||
The 1 is the highest priority.
|
||
The 10 is the lowest priority.
|
||
"
|
||
::= { setGpsEntry 5 }
|
||
|
||
setGpsPdop OBJECT-TYPE
|
||
SYNTAX INTEGER (3..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PDOP mask [3 to 10].
|
||
"
|
||
::= { setGpsEntry 6 }
|
||
|
||
setGpsPosel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum satellite elevation mask for positioning [0 to 90 deg].
|
||
"
|
||
::= { setGpsEntry 7 }
|
||
|
||
setGpsTimel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum satellite elevation mask for timing [0 to 90 deg].
|
||
"
|
||
::= { setGpsEntry 8 }
|
||
|
||
setGpsAvg OBJECT-TYPE
|
||
SYNTAX INTEGER (20..3600)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set satellite position averaging value [20-3600].
|
||
Mot GPS: (20 - 3600) of averages for the calculated position fixes
|
||
NVS GNSS: (20 - 1440) of averaging minutes
|
||
"
|
||
::= { setGpsEntry 9 }
|
||
|
||
setGpsLat OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna latitude of the GPS antenna.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The latitude is +/- 90 deg.
|
||
"
|
||
::= { setGpsEntry 10 }
|
||
|
||
setGpsLon OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna longitude of the GPS antenna.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The longitude is +/- 180 deg.
|
||
"
|
||
::= { setGpsEntry 11 }
|
||
|
||
setGpsHgt OBJECT-TYPE
|
||
SYNTAX TAntHeight
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna height (meter) of the GPS antenna.
|
||
|
||
The format is +hh.hh or -hh.hh
|
||
The height is +/- 10000.0 meters.
|
||
"
|
||
::= { setGpsEntry 12 }
|
||
|
||
|
||
setGpsZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set phase error to zero for this GPS port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setGpsEntry 13 }
|
||
|
||
|
||
setGpsTodsrcPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TODSRC (Time-Of-Day Source) priority.
|
||
The priority is the for the specified module as the TOD Source, default is 0, range can be 0 through 8.
|
||
Value 1 is the highest and 8 is the lowest.
|
||
If the value is zero, the specified module cannot be TOD Source.
|
||
"
|
||
::= { setGpsEntry 14 }
|
||
|
||
setGpsTodsrcCompensation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..250)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Antenna cable delay compensation {0 <20> 250} in the case of GPS
|
||
TOD Source(s) or the delay induced by the cable(s) used to connect
|
||
expansion shelves where the PackeTime ToD Source(s) is located in
|
||
relationship to the Main shelf. The time offset shall have a 100nS
|
||
resolution, thus the Delay value shall be multiplied by 100nS to
|
||
provide 1PPS compensation.
|
||
|
||
Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
|
||
"
|
||
::= { setGpsEntry 15 }
|
||
|
||
setGnssConsMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gps(1),
|
||
glonass(2),
|
||
gpsGlonass(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set constellation mode of GNSS engine.
|
||
gps(1), -- The constellation mode of gnss engine is gps.
|
||
glonass(2), -- The constellation mode of gnss engine is glonass
|
||
gpsGlonass(3), -- The constellation mode of gnss engine is gps+glonass.
|
||
"
|
||
::= { setGpsEntry 16 }
|
||
|
||
-- ******************************************
|
||
-- GPS INPUT ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThGpsInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMgEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS input alarm attribute setup information.
|
||
"
|
||
::= { setupGps 2 }
|
||
|
||
|
||
setMgEntry OBJECT-TYPE
|
||
SYNTAX SetMgEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMgChassis
|
||
Identifies which chassis is being addressed.
|
||
setMgSlot
|
||
Identifies which slot position is being addressed.
|
||
setMgMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMgMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMgMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMgMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMgMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMgMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMgMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMgMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMgMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMgMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMgMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMgMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMgMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMgMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMgMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMgMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMgMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMgMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMgMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMgMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMgMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMgFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMgFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMgFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMgFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMgFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMgFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
INDEX { setMgChassis, setMgSlot }
|
||
::= { setAlmThGpsInpTable 1 }
|
||
|
||
|
||
SetMgEntry ::=
|
||
SEQUENCE {
|
||
setMgChassis
|
||
INTEGER,
|
||
setMgSlot
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMgMtieStd
|
||
INTEGER,
|
||
|
||
setMgMtie10EL1
|
||
INTEGER,
|
||
setMgMtie10EL2
|
||
INTEGER,
|
||
setMgMtie10CL1
|
||
INTEGER,
|
||
setMgMtie10CL2
|
||
INTEGER,
|
||
|
||
setMgMtie100EL1
|
||
INTEGER,
|
||
setMgMtie100EL2
|
||
INTEGER,
|
||
setMgMtie100CL1
|
||
INTEGER,
|
||
setMgMtie100CL2
|
||
INTEGER,
|
||
|
||
setMgMtie1000EL1
|
||
INTEGER,
|
||
setMgMtie1000EL2
|
||
INTEGER,
|
||
setMgMtie1000CL1
|
||
INTEGER,
|
||
setMgMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMgMtie10000EL1
|
||
INTEGER,
|
||
setMgMtie10000EL2
|
||
INTEGER,
|
||
setMgMtie10000CL1
|
||
INTEGER,
|
||
setMgMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMgMtie100000EL1
|
||
INTEGER,
|
||
setMgMtie100000EL2
|
||
INTEGER,
|
||
setMgMtie100000CL1
|
||
INTEGER,
|
||
setMgMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMgFreqAErrLmt
|
||
INTEGER,
|
||
setMgFreqAClrLmt
|
||
INTEGER,
|
||
setMgFreqATau
|
||
INTEGER,
|
||
|
||
setMgFreqBErrLmt
|
||
INTEGER,
|
||
setMgFreqBClrLmt
|
||
INTEGER,
|
||
setMgFreqBTau
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setMgChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMgEntry 1 }
|
||
|
||
setMgSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { setMgEntry 2 }
|
||
|
||
setMgMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMgEntry 3 }
|
||
|
||
setMgMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 4 }
|
||
|
||
setMgMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 5 }
|
||
|
||
setMgMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 6 }
|
||
|
||
setMgMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 7 }
|
||
|
||
|
||
setMgMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 8 }
|
||
|
||
setMgMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 9 }
|
||
|
||
setMgMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 10 }
|
||
|
||
setMgMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 11 }
|
||
|
||
|
||
setMgMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 12 }
|
||
|
||
setMgMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 13 }
|
||
|
||
setMgMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 14 }
|
||
|
||
setMgMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 15 }
|
||
|
||
setMgMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 16 }
|
||
|
||
setMgMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 17 }
|
||
|
||
|
||
setMgMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 18 }
|
||
|
||
setMgMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 19 }
|
||
|
||
|
||
setMgMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 20 }
|
||
|
||
setMgMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 21 }
|
||
|
||
|
||
setMgMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 22 }
|
||
|
||
setMgMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 23 }
|
||
|
||
setMgFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMgEntry 24 }
|
||
|
||
setMgFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMgEntry 25 }
|
||
|
||
setMgFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
"
|
||
::= { setMgEntry 26 }
|
||
|
||
|
||
setMgFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMgEntry 27 }
|
||
|
||
setMgFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMgEntry 28 }
|
||
|
||
setMgFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
::= { setMgEntry 29 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 INPUT MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- DS1/E1 INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of DS1/E1 attribute setup information.
|
||
"
|
||
::= { setupDs1E1Inp 2 }
|
||
|
||
|
||
setDiEntry OBJECT-TYPE
|
||
SYNTAX SetDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setDiChassis, setDiSlot, setDiPort }
|
||
::= { setDs1E1InpTable 1 }
|
||
|
||
SetDiEntry ::=
|
||
SEQUENCE {
|
||
setDiChassis
|
||
INTEGER,
|
||
setDiSlot
|
||
INTEGER,
|
||
setDiPort
|
||
INTEGER,
|
||
setDiEnable
|
||
EnaValue,
|
||
setDiFrame
|
||
INTEGER,
|
||
setDiZS
|
||
OnValue,
|
||
setDiCRC
|
||
OnValue,
|
||
setDiSSM
|
||
OnValue,
|
||
setDiProvPql
|
||
INTEGER,
|
||
setDiPriority
|
||
INTEGER,
|
||
setDiGain
|
||
OnValue,
|
||
setDiCSFlt
|
||
INTEGER,
|
||
setDiE1SsmBit
|
||
INTEGER,
|
||
setDiZeroPhase
|
||
INTEGER,
|
||
setDiMtieCalc
|
||
INTEGER
|
||
}
|
||
|
||
setDiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setDiEntry 1 }
|
||
|
||
setDiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDiEntry 2 }
|
||
|
||
|
||
setDiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDiEntry 3 }
|
||
|
||
|
||
setDiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 4 }
|
||
|
||
|
||
setDiFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
esf(1),
|
||
d4(2),
|
||
ccs(3),
|
||
cas(4),
|
||
mhz1(5),
|
||
khz1544(6),
|
||
khz2048(7),
|
||
mhz5(8),
|
||
mhz10(9)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input framing type or clock frequency.
|
||
esf(1), -- T1 ESF
|
||
d4(2), -- T1 D4
|
||
ccs(3), -- E1 CCS
|
||
cas(4), -- E1 CAS
|
||
mhz1(5), -- Clock 1MHz
|
||
khz1544(6), -- Clock 1544kHz
|
||
khz2048(7), -- Clock 2048kHz
|
||
mhz5(8), -- Clock 5MHz
|
||
mhz10(9) -- Clock 10MHz
|
||
"
|
||
::= { setDiEntry 5 }
|
||
|
||
setDiZS OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Zero Supression (ZS) on the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 6 }
|
||
|
||
setDiCRC OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set CRC verificaiton on the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 7 }
|
||
|
||
setDiSSM OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Sync Status Messaging (SSM) on the input port to enabled or disabled..
|
||
"
|
||
::= { setDiEntry 8 }
|
||
|
||
setDiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setDiEntry 9 }
|
||
|
||
|
||
setDiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setDiEntry 10 }
|
||
|
||
setDiGain OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port gain setting to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 11 }
|
||
|
||
setDiCSFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
low(2),
|
||
high(3),
|
||
na(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input Port 1 for external Cesium (CS) fault alarm logic level.
|
||
off(1), -- function is disabled
|
||
low(2), -- function is enabled, will trigger on low (0V) level
|
||
high(3), -- function is enabled, will trigger on high (+5v) level
|
||
na(4) -- not applicable
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setDiEntry 12 }
|
||
|
||
setDiE1SsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port E1 Sync Status Message (SSM) bit position.
|
||
|
||
This command is only meaningful for the E1 input module.
|
||
For DS1, this value is always 4, and has no meaning (i.e. not used).
|
||
"
|
||
::= { setDiEntry 13 }
|
||
|
||
|
||
setDiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setDiEntry 14 }
|
||
|
||
setDiMtieCalc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
hz40(1),
|
||
hz1(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports MTIE calculator (40Hz or 1Hz) being used
|
||
|
||
The number represents the input port setting for MTIE Calculator measurement.
|
||
- 40Hz - Selects the 40Hz MTIE values to set/clear MTIE alarms
|
||
- 1Hz - Selects the 1Hz MTIE values to set/clear MTIE alarms
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setDiEntry 15 }
|
||
|
||
|
||
-- ******************************************
|
||
-- DS1/E1 INPUT ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1/E1 input alarm attributes and settings information.
|
||
"
|
||
::= { setupDs1E1Inp 4 }
|
||
|
||
|
||
setMiEntry OBJECT-TYPE
|
||
SYNTAX SetMiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMiPort
|
||
Identifies which port position is being addressed.
|
||
setMiMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMiMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMiMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMiMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMiMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMiMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMiMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMiMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMiMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMiMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMiMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMiMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMiMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMiMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMiMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMiMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMiMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMiMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMiMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMiMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMiMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMiFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMiFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMiFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMiFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMiFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMiFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
setMiLOSErrCnt
|
||
Set the input port error count threshold for LOS signal faults.
|
||
setMiLOSClrCnt
|
||
Set the input port clear count threshold for LOS signal faults.
|
||
setMiAISErrCnt
|
||
Set the input port error count threshold for AIS signal faults.
|
||
setMiAISClrCnt
|
||
Set the input port clear count threshold for AIS signal faults.
|
||
setMiOOFErrCnt
|
||
Set the input port error count threshold for OOF signal faults.
|
||
setMiOOFClrCnt
|
||
Set the input port clear count threshold for OOF signal faults.
|
||
setMiBPVErrCnt
|
||
Set the input port error count threshold for BPV signal faults.
|
||
setMiBPVClrCnt
|
||
Set the input port clear count threshold for BPV signal faults.
|
||
setMiCRCErrCnt
|
||
Set the input port error count threshold for CRC signal faults.
|
||
setMiCRCClrCnt
|
||
Set the input port clear count threshold for CRC signal faults.
|
||
"
|
||
INDEX { setMiChassis, setMiSlot, setMiPort }
|
||
::= { setAlmThDs1E1InpTable 1 }
|
||
|
||
|
||
SetMiEntry ::=
|
||
SEQUENCE {
|
||
setMiChassis
|
||
INTEGER,
|
||
setMiSlot
|
||
INTEGER,
|
||
setMiPort
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMiMtieStd
|
||
INTEGER,
|
||
|
||
setMiMtie10EL1
|
||
INTEGER,
|
||
setMiMtie10EL2
|
||
INTEGER,
|
||
setMiMtie10CL1
|
||
INTEGER,
|
||
setMiMtie10CL2
|
||
INTEGER,
|
||
|
||
setMiMtie100EL1
|
||
INTEGER,
|
||
setMiMtie100EL2
|
||
INTEGER,
|
||
setMiMtie100CL1
|
||
INTEGER,
|
||
setMiMtie100CL2
|
||
INTEGER,
|
||
|
||
setMiMtie1000EL1
|
||
INTEGER,
|
||
setMiMtie1000EL2
|
||
INTEGER,
|
||
setMiMtie1000CL1
|
||
INTEGER,
|
||
setMiMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMiMtie10000EL1
|
||
INTEGER,
|
||
setMiMtie10000EL2
|
||
INTEGER,
|
||
setMiMtie10000CL1
|
||
INTEGER,
|
||
setMiMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMiMtie100000EL1
|
||
INTEGER,
|
||
setMiMtie100000EL2
|
||
INTEGER,
|
||
setMiMtie100000CL1
|
||
INTEGER,
|
||
setMiMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMiFreqAErrLmt
|
||
INTEGER,
|
||
setMiFreqAClrLmt
|
||
INTEGER,
|
||
setMiFreqATau
|
||
INTEGER,
|
||
|
||
setMiFreqBErrLmt
|
||
INTEGER,
|
||
setMiFreqBClrLmt
|
||
INTEGER,
|
||
setMiFreqBTau
|
||
INTEGER,
|
||
|
||
-- SIGNAL Threshold Setting
|
||
setMiLOSErrCnt
|
||
INTEGER,
|
||
setMiLOSClrCnt
|
||
INTEGER,
|
||
setMiAISErrCnt
|
||
INTEGER,
|
||
setMiAISClrCnt
|
||
INTEGER,
|
||
setMiOOFErrCnt
|
||
INTEGER,
|
||
setMiOOFClrCnt
|
||
INTEGER,
|
||
setMiBPVErrCnt
|
||
INTEGER,
|
||
setMiBPVClrCnt
|
||
INTEGER,
|
||
setMiCRCErrCnt
|
||
INTEGER,
|
||
setMiCRCClrCnt
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setMiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMiEntry 1 }
|
||
|
||
setMiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMiEntry 2 }
|
||
|
||
|
||
setMiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMiEntry 3 }
|
||
|
||
setMiMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMiEntry 4 }
|
||
|
||
setMiMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 5 }
|
||
|
||
setMiMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 6 }
|
||
|
||
setMiMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 7 }
|
||
|
||
setMiMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 8 }
|
||
|
||
|
||
|
||
setMiMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 9 }
|
||
|
||
setMiMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 10 }
|
||
|
||
setMiMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 11 }
|
||
|
||
setMiMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 12 }
|
||
|
||
|
||
setMiMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 13 }
|
||
|
||
setMiMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 14 }
|
||
|
||
setMiMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 15 }
|
||
|
||
setMiMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 16 }
|
||
|
||
|
||
|
||
setMiMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 17 }
|
||
|
||
setMiMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 18 }
|
||
|
||
|
||
setMiMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 19 }
|
||
|
||
setMiMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 20 }
|
||
|
||
|
||
setMiMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 21 }
|
||
|
||
setMiMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 22 }
|
||
|
||
|
||
setMiMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 23 }
|
||
|
||
setMiMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 24 }
|
||
|
||
|
||
|
||
setMiFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMiEntry 25 }
|
||
|
||
setMiFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMiEntry 26 }
|
||
|
||
setMiFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
|
||
"
|
||
::= { setMiEntry 27 }
|
||
|
||
|
||
setMiFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMiEntry 28 }
|
||
|
||
setMiFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMiEntry 29 }
|
||
|
||
setMiFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
|
||
"
|
||
::= { setMiEntry 30 }
|
||
|
||
setMiLOSErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for LOS signal faults.
|
||
"
|
||
::= { setMiEntry 31 }
|
||
|
||
setMiLOSClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for LOS signal faults.
|
||
"
|
||
::= { setMiEntry 32 }
|
||
|
||
setMiAISErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for AIS signal faults.
|
||
"
|
||
::= { setMiEntry 33 }
|
||
|
||
setMiAISClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for AIS signal faults.
|
||
"
|
||
::= { setMiEntry 34 }
|
||
|
||
setMiOOFErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for OOF signal faults.
|
||
"
|
||
::= { setMiEntry 35 }
|
||
|
||
setMiOOFClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for OOF signal faults.
|
||
"
|
||
::= { setMiEntry 36 }
|
||
|
||
setMiBPVErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for BPV signal faults.
|
||
"
|
||
::= { setMiEntry 37 }
|
||
|
||
setMiBPVClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
::= { setMiEntry 38 }
|
||
|
||
setMiCRCErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count hreshold for CRC signal faults.
|
||
"
|
||
::= { setMiEntry 39 }
|
||
|
||
setMiCRCClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for CRC signal faults.
|
||
"
|
||
::= { setMiEntry 40 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMPOSITE CLOCK INPUT MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- COMPOSITE CLOCK INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of CC Input attribute setup information.
|
||
"
|
||
::= { setupCcInp 2 }
|
||
|
||
|
||
setCiEntry OBJECT-TYPE
|
||
SYNTAX SetCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setCiChassis, setCiSlot, setCiPort }
|
||
::= { setCcInpTable 1 }
|
||
|
||
SetCiEntry ::=
|
||
SEQUENCE {
|
||
setCiChassis
|
||
INTEGER,
|
||
setCiSlot
|
||
INTEGER,
|
||
setCiPort
|
||
INTEGER,
|
||
setCiEnable
|
||
EnaValue,
|
||
setCiProvPql
|
||
INTEGER,
|
||
setCiPriority
|
||
INTEGER,
|
||
setCiZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setCiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setCiEntry 1 }
|
||
|
||
setCiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCiEntry 2 }
|
||
|
||
|
||
setCiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCiEntry 3 }
|
||
|
||
|
||
setCiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setCiEntry 4 }
|
||
|
||
setCiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setCiEntry 7 }
|
||
|
||
|
||
setCiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setCiEntry 8 }
|
||
|
||
|
||
setCiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setCiEntry 9 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- CCINP ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCimEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of CC input alarm attributes and settings information.
|
||
"
|
||
::= { setupCcInp 4 }
|
||
|
||
|
||
setCimEntry OBJECT-TYPE
|
||
SYNTAX SetCimEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMiPort
|
||
Identifies which port position is being addressed.
|
||
setCimLOSErrCnt
|
||
Set the input port error count threshold for LOS signal faults.
|
||
setCimLOSClrCnt
|
||
Set the input port clear count threshold for LOS signal faults.
|
||
setCimBPVErrCnt
|
||
Set the input port error count threshold for BPV signal faults.
|
||
setCimBPVClrCnt
|
||
Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
INDEX { setCimChassis, setCimSlot, setCimPort }
|
||
::= { setAlmThCcInpTable 1 }
|
||
|
||
|
||
SetCimEntry ::=
|
||
SEQUENCE {
|
||
setCimChassis
|
||
INTEGER,
|
||
setCimSlot
|
||
INTEGER,
|
||
setCimPort
|
||
INTEGER,
|
||
|
||
-- SIGNAL Threshold Setting
|
||
setCimLOSErrCnt
|
||
INTEGER,
|
||
setCimLOSClrCnt
|
||
INTEGER,
|
||
setCimBPVErrCnt
|
||
INTEGER,
|
||
setCimBPVClrCnt
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setCimChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setCimEntry 1 }
|
||
|
||
setCimSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCimEntry 2 }
|
||
|
||
|
||
setCimPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCimEntry 3 }
|
||
|
||
setCimLOSErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for LOS signal faults.
|
||
"
|
||
::= { setCimEntry 4 }
|
||
|
||
setCimLOSClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for LOS signal faults.
|
||
"
|
||
::= { setCimEntry 5 }
|
||
|
||
setCimBPVErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for BPV signal faults.
|
||
"
|
||
::= { setCimEntry 10 }
|
||
|
||
setCimBPVClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
::= { setCimEntry 11 }
|
||
|
||
|
||
-- ******************************************
|
||
-- JAPANESE SINE INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of Sine Input attribute setup information.
|
||
"
|
||
::= { setupSineInp 2 }
|
||
|
||
|
||
setSineiEntry OBJECT-TYPE
|
||
SYNTAX SetSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setSineiChassis, setSineiSlot, setSineiPort }
|
||
::= { setSineInpTable 1 }
|
||
|
||
SetSineiEntry ::=
|
||
SEQUENCE {
|
||
setSineiChassis
|
||
INTEGER,
|
||
setSineiSlot
|
||
INTEGER,
|
||
setSineiPort
|
||
INTEGER,
|
||
setSineiEnable
|
||
EnaValue,
|
||
setSineiFrequency
|
||
INTEGER,
|
||
setSineiProvPql
|
||
INTEGER,
|
||
setSineiPriority
|
||
INTEGER,
|
||
setSineiCSFlt
|
||
INTEGER,
|
||
|
||
setSineiZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setSineiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setSineiEntry 1 }
|
||
|
||
setSineiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineiEntry 2 }
|
||
|
||
|
||
setSineiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineiEntry 3 }
|
||
|
||
|
||
setSineiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setSineiEntry 4 }
|
||
|
||
|
||
setSineiFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (1544|6312)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input signal frequency.
|
||
The frequency can be set: 1.544MHZ/ 6.312MHz.
|
||
"
|
||
::= { setSineiEntry 5 }
|
||
|
||
setSineiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setSineiEntry 6 }
|
||
|
||
|
||
setSineiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setSineiEntry 7 }
|
||
|
||
|
||
setSineiCSFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
low(2),
|
||
high(3),
|
||
na(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input Port 1 for external Cesium (CS) fault alarm logic level.
|
||
off(1), -- function is disabled
|
||
low(2), -- function is enabled, will trigger on low (0V) level
|
||
high(3), -- function is enabled, will trigger on high (+5v) level
|
||
na(4) -- not applicable
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setSineiEntry 8 }
|
||
|
||
setSineiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setSineiEntry 9 }
|
||
|
||
|
||
|
||
-- *******************************************
|
||
-- JAPANESE SINE INPUT ALARM THRESHOLD SETTING
|
||
-- *******************************************
|
||
|
||
setAlmThSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMsiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine input alarm attributes and settings information.
|
||
"
|
||
::= { setupSineInp 4 }
|
||
|
||
setMsiEntry OBJECT-TYPE
|
||
SYNTAX SetMsiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMsiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMsiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMsiPort
|
||
Identifies which port position is being addressed.
|
||
setMsiMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMsiMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMsiMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMsiMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMsiMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMsiMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMsiMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMsiMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMsiMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMsiMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMsiMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMsiMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMsiMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMsiMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMsiMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMsiMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMsiMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMsiMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMsiFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMsiFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMsiFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMsiFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMsiFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMsiFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
INDEX { setMsiChassis, setMsiSlot, setMsiPort }
|
||
::= { setAlmThSineInpTable 1 }
|
||
|
||
SetMsiEntry ::=
|
||
SEQUENCE {
|
||
setMsiChassis
|
||
INTEGER,
|
||
setMsiSlot
|
||
INTEGER,
|
||
setMsiPort
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMsiMtieStd
|
||
INTEGER,
|
||
|
||
setMsiMtie10EL1
|
||
INTEGER,
|
||
setMsiMtie10EL2
|
||
INTEGER,
|
||
setMsiMtie10CL1
|
||
INTEGER,
|
||
setMsiMtie10CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie100EL1
|
||
INTEGER,
|
||
setMsiMtie100EL2
|
||
INTEGER,
|
||
setMsiMtie100CL1
|
||
INTEGER,
|
||
setMsiMtie100CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie1000EL1
|
||
INTEGER,
|
||
setMsiMtie1000EL2
|
||
INTEGER,
|
||
setMsiMtie1000CL1
|
||
INTEGER,
|
||
setMsiMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie10000EL1
|
||
INTEGER,
|
||
setMsiMtie10000EL2
|
||
INTEGER,
|
||
setMsiMtie10000CL1
|
||
INTEGER,
|
||
setMsiMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie100000EL1
|
||
INTEGER,
|
||
setMsiMtie100000EL2
|
||
INTEGER,
|
||
setMsiMtie100000CL1
|
||
INTEGER,
|
||
setMsiMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMsiFreqAErrLmt
|
||
INTEGER,
|
||
setMsiFreqAClrLmt
|
||
INTEGER,
|
||
setMsiFreqATau
|
||
INTEGER,
|
||
|
||
setMsiFreqBErrLmt
|
||
INTEGER,
|
||
setMsiFreqBClrLmt
|
||
INTEGER,
|
||
setMsiFreqBTau
|
||
INTEGER
|
||
}
|
||
|
||
setMsiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMsiEntry 1 }
|
||
|
||
setMsiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMsiEntry 2 }
|
||
|
||
|
||
setMsiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMsiEntry 3 }
|
||
|
||
setMsiMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMsiEntry 4 }
|
||
|
||
setMsiMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 5 }
|
||
|
||
setMsiMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 6 }
|
||
|
||
setMsiMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 7 }
|
||
|
||
setMsiMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 8 }
|
||
|
||
|
||
|
||
setMsiMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 9 }
|
||
|
||
setMsiMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 10 }
|
||
|
||
setMsiMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 11 }
|
||
|
||
setMsiMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 12 }
|
||
|
||
|
||
setMsiMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 13 }
|
||
|
||
setMsiMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 14 }
|
||
|
||
setMsiMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 15 }
|
||
|
||
setMsiMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 16 }
|
||
|
||
|
||
|
||
setMsiMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 17 }
|
||
|
||
setMsiMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 18 }
|
||
|
||
|
||
setMsiMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 19 }
|
||
|
||
setMsiMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 20 }
|
||
|
||
|
||
setMsiMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 21 }
|
||
|
||
setMsiMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 22 }
|
||
|
||
setMsiMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 23 }
|
||
|
||
setMsiMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 24 }
|
||
|
||
|
||
|
||
setMsiFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMsiEntry 25 }
|
||
|
||
setMsiFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMsiEntry 26 }
|
||
|
||
setMsiFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
|
||
"
|
||
::= { setMsiEntry 27 }
|
||
|
||
|
||
setMsiFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMsiEntry 28 }
|
||
|
||
setMsiFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMsiEntry 29 }
|
||
|
||
setMsiFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
|
||
"
|
||
::= { setMsiEntry 30 }
|
||
|
||
-- ******************************************
|
||
-- JAPANESE CC INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setJccInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of CC Input attribute setup information.
|
||
"
|
||
::= { setupJccInp 2 }
|
||
|
||
|
||
setJcciEntry OBJECT-TYPE
|
||
SYNTAX SetJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setJcciChassis, setJcciSlot, setJcciPort }
|
||
::= { setJccInpTable 1 }
|
||
|
||
SetJcciEntry ::=
|
||
SEQUENCE {
|
||
setJcciChassis
|
||
INTEGER,
|
||
setJcciSlot
|
||
INTEGER,
|
||
setJcciPort
|
||
INTEGER,
|
||
setJcciEnable
|
||
EnaValue,
|
||
setJcciProvPql
|
||
INTEGER,
|
||
setJcciPriority
|
||
INTEGER,
|
||
setJcci400Hz
|
||
OnValue,
|
||
|
||
setJcciZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setJcciChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setJcciEntry 1 }
|
||
|
||
setJcciSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setJcciEntry 2 }
|
||
|
||
|
||
setJcciPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setJcciEntry 3 }
|
||
|
||
|
||
setJcciEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setJcciEntry 4 }
|
||
|
||
|
||
setJcciProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setJcciEntry 5 }
|
||
|
||
|
||
setJcciPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setJcciEntry 6 }
|
||
|
||
setJcci400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port 400Hz signal attribute.
|
||
"
|
||
::= { setJcciEntry 7 }
|
||
|
||
setJcciZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setJcciEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 OUT SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- DS1 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setDsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetDsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 output module status and settings.
|
||
"
|
||
::= { setupDs1Out 2 }
|
||
|
||
|
||
setDsEntry OBJECT-TYPE
|
||
SYNTAX SetDsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 output attributes.
|
||
"
|
||
INDEX { setDsChassis, setDsSlot}
|
||
::= { setDsTable 1 }
|
||
|
||
SetDsEntry ::=
|
||
SEQUENCE {
|
||
setDsChassis
|
||
INTEGER,
|
||
setDsSlot
|
||
INTEGER,
|
||
setDsFrame
|
||
INTEGER,
|
||
setDsBypass
|
||
OnValue,
|
||
setDsZs
|
||
OnValue,
|
||
setDsEnable
|
||
OCTET STRING,
|
||
setDsLength
|
||
OCTET STRING
|
||
}
|
||
|
||
setDsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDsEntry 1 }
|
||
|
||
setDsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDsEntry 2 }
|
||
|
||
|
||
setDsFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
esf(1),
|
||
d4(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output signal framing mode.
|
||
The T1 framing mode is ESF or D4.
|
||
"
|
||
::= { setDsEntry 3 }
|
||
|
||
setDsBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setDsEntry 4 }
|
||
|
||
setDsZs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setDsEntry 5 }
|
||
|
||
|
||
setDsEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setDsEntry 6 }
|
||
|
||
setDsLength OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the cable length compensation for the output port.
|
||
|
||
Cable length definitions:
|
||
1 = 133 ft
|
||
2 = 266 ft
|
||
3 = 399 ft
|
||
4 = 533 ft
|
||
5 = 655 ft
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setDsEntry 7 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- E1 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setE1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 output module status and settings.
|
||
"
|
||
::= { setupE1Out 2 }
|
||
|
||
|
||
setE1Entry OBJECT-TYPE
|
||
SYNTAX SetE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 output attributes.
|
||
"
|
||
INDEX { setE1Chassis, setE1Slot}
|
||
::= { setE1Table 1 }
|
||
|
||
SetE1Entry ::=
|
||
SEQUENCE {
|
||
setE1Chassis
|
||
INTEGER,
|
||
setE1Slot
|
||
INTEGER,
|
||
setE1Frame
|
||
INTEGER,
|
||
setE1Bypass
|
||
OnValue,
|
||
setE1Zs
|
||
OnValue,
|
||
setE1Crc
|
||
OnValue,
|
||
setE1SsmBit
|
||
INTEGER,
|
||
setE1Enable
|
||
OCTET STRING
|
||
}
|
||
|
||
setE1Chassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE1Entry 1 }
|
||
|
||
setE1Slot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE1Entry 2 }
|
||
|
||
|
||
setE1Frame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ccs(1),
|
||
cas(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output signal framing mode.
|
||
1=ccs
|
||
2=cas
|
||
"
|
||
::= { setE1Entry 3 }
|
||
|
||
setE1Bypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setE1Entry 4 }
|
||
|
||
setE1Zs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setE1Entry 5 }
|
||
|
||
setE1Crc OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the CRC error checking to enable or disable.
|
||
"
|
||
::= { setE1Entry 6 }
|
||
|
||
|
||
setE1SsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set output module E1 SSM bit position.
|
||
bit=4 - 8
|
||
|
||
Note: This field is only valid for E1 output module.
|
||
"
|
||
::= { setE1Entry 7 }
|
||
|
||
setE1Enable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE1Entry 8 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- 2048kHz OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setCoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of 2048kHz output module status and settings.
|
||
"
|
||
::= { setup2048Out 2 }
|
||
|
||
setCoEntry OBJECT-TYPE
|
||
SYNTAX SetCoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set 2048kHz output attributes.
|
||
"
|
||
INDEX { setCoChassis, setCoSlot}
|
||
::= { setCoTable 1 }
|
||
|
||
SetCoEntry ::=
|
||
SEQUENCE {
|
||
setCoChassis
|
||
INTEGER,
|
||
setCoSlot
|
||
INTEGER,
|
||
setCoBypass
|
||
OnValue,
|
||
setCoFltMode
|
||
INTEGER,
|
||
setCoEnable
|
||
OCTET STRING,
|
||
setCoSquelch
|
||
OCTET STRING
|
||
}
|
||
|
||
setCoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCoEntry 1 }
|
||
|
||
setCoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCoEntry 2 }
|
||
|
||
setCoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setCoEntry 3 }
|
||
|
||
setCoFltMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
on(2),
|
||
auto(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the signal fault mode for low level output signals
|
||
off(1), -- will turn off the output and requires user issued command to turn it back on
|
||
on(2), -- will not turn off when fault detected
|
||
auto(3) -- will turn off the output and automatically turn back on when fault clears
|
||
"
|
||
::= { setCoEntry 4 }
|
||
|
||
setCoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCoEntry 5 }
|
||
|
||
setCoSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PQL threshold to turn port off.
|
||
If the system PQL is below the PWL threshold the port is turned off (i.e. squelched).
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The PQL value of each byte defined as follows:
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
"
|
||
::= { setCoEntry 6 }
|
||
|
||
-- ******************************************
|
||
-- COMPOSITE CLOCK OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setCcTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCcEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock (CC) output module status and settings.
|
||
"
|
||
::= { setupCCOut 2 }
|
||
|
||
setCcEntry OBJECT-TYPE
|
||
SYNTAX SetCcEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set CC output attributes.
|
||
"
|
||
INDEX { setCcChassis, setCcSlot}
|
||
::= { setCcTable 1 }
|
||
|
||
SetCcEntry ::=
|
||
SEQUENCE {
|
||
setCcChassis
|
||
INTEGER,
|
||
setCcSlot
|
||
INTEGER,
|
||
setCcBypass
|
||
OnValue,
|
||
setCcEnable
|
||
OCTET STRING,
|
||
setCcDuty
|
||
OCTET STRING,
|
||
setCcComp
|
||
OCTET STRING
|
||
}
|
||
|
||
setCcChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each CC Output entry.
|
||
"
|
||
::= { setCcEntry 1 }
|
||
|
||
setCcSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each CC Output entry.
|
||
"
|
||
::= { setCcEntry 2 }
|
||
|
||
setCcBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setCcEntry 3 }
|
||
|
||
setCcEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 4 }
|
||
|
||
|
||
setCcDuty OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output duty cycle for the output ports.
|
||
1 = 63/37 duty cycle.
|
||
2 = 50/50 duty cycle.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 5 }
|
||
|
||
|
||
setCcComp OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output phase (cable) compensation for the output ports.
|
||
|
||
The equivalent cable length:
|
||
1 = 2200 ft,
|
||
2 = 1925 ft,
|
||
3 = 1650 ft,
|
||
4 = 1375 ft,
|
||
5 = 1100 ft,
|
||
6 = 825 ft,
|
||
7 = 550 ft,
|
||
8 = 275 ft.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- RS422 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
set422oTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Set422oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of 2048kHz output module status and settings.
|
||
"
|
||
::= { setup422Out 2 }
|
||
|
||
set422oEntry OBJECT-TYPE
|
||
SYNTAX Set422oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set 422 output attributes.
|
||
"
|
||
INDEX { set422oChassis, set422oSlot}
|
||
::= { set422oTable 1 }
|
||
|
||
Set422oEntry ::=
|
||
SEQUENCE {
|
||
set422oChassis
|
||
INTEGER,
|
||
set422oSlot
|
||
INTEGER,
|
||
set422oBypass
|
||
OnValue,
|
||
set422oFltMode
|
||
INTEGER,
|
||
set422oEnable
|
||
OCTET STRING,
|
||
set422oFrequency
|
||
OCTET STRING
|
||
}
|
||
|
||
set422oChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { set422oEntry 1 }
|
||
|
||
set422oSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { set422oEntry 2 }
|
||
|
||
set422oBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { set422oEntry 3 }
|
||
|
||
set422oFltMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
on(2),
|
||
auto(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the signal fault mode for low level output signals
|
||
off(1), -- will turn off the output and requires user issued command to turn it back on
|
||
on(2), -- will not turn off when fault detected
|
||
auto(3) -- will turn off the output and automatically turn back on when fault clears
|
||
"
|
||
::= { set422oEntry 4 }
|
||
|
||
set422oEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { set422oEntry 5 }
|
||
|
||
set422oFrequency OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set frequency for each port on an RS422 output module.
|
||
|
||
word 1 = port 1, word 10 = port 10.
|
||
The frequency value of each port defined as follows:
|
||
0 = 4kHz, 1-512 = 8kHz to 4096kHz with 8kHz per step.
|
||
|
||
Note: each port use 2-bytes to set frequency.
|
||
User can only set frequency on port 1 thru port 10.
|
||
The port 1 and 11, port 2 and 12,.., port 10 and 20 have the same frequency setting.
|
||
For example, when you set port1, you are set the same frequency for port 11.
|
||
"
|
||
::= { set422oEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- Selectable E1/2048 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setE12048oTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetE12048oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1/2048 output module status and settings.
|
||
"
|
||
::= { setupE12048Out 2 }
|
||
|
||
setE12048oEntry OBJECT-TYPE
|
||
SYNTAX SetE12048oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1/2048 output attributes.
|
||
"
|
||
INDEX { setE12048oChassis, setE12048oSlot}
|
||
::= { setE12048oTable 1 }
|
||
|
||
SetE12048oEntry ::=
|
||
SEQUENCE {
|
||
setE12048oChassis
|
||
INTEGER,
|
||
setE12048oSlot
|
||
INTEGER,
|
||
setE12048oBypass
|
||
OnValue,
|
||
setE12048oZs
|
||
OnValue,
|
||
setE12048oSignal
|
||
OCTET STRING,
|
||
setE12048oEnable
|
||
OCTET STRING,
|
||
setE12048oSquelch
|
||
OCTET STRING,
|
||
setE12048oFrame
|
||
INTEGER,
|
||
setE12048oCrc
|
||
OnValue,
|
||
setE12048oSsm
|
||
OnValue,
|
||
setE12048oSsmBit
|
||
INTEGER
|
||
}
|
||
|
||
setE12048oChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE12048oEntry 1 }
|
||
|
||
setE12048oSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE12048oEntry 2 }
|
||
|
||
setE12048oBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setE12048oEntry 3 }
|
||
|
||
setE12048oZs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setE12048oEntry 4 }
|
||
|
||
setE12048oSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to E1 or 2048kHz.
|
||
1 = E1
|
||
2 = 2048 kHz
|
||
|
||
Note: byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 5 }
|
||
|
||
setE12048oEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 6 }
|
||
|
||
setE12048oSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PQL squelch threshold for each port.
|
||
If a PQL threshold is below the system PQL, this port is turned off (i.e. squelched).
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 7 }
|
||
|
||
setE12048oFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ccs(1),
|
||
cas(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output signal framer mode.
|
||
1 = CCS
|
||
2 = CAS
|
||
"
|
||
::= { setE12048oEntry 8 }
|
||
|
||
setE12048oCrc OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output CRC error checking to on or off.
|
||
"
|
||
::= { setE12048oEntry 9 }
|
||
|
||
setE12048oSsm OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output SSM generation to on or off.
|
||
"
|
||
::= { setE12048oEntry 10 }
|
||
|
||
setE12048oSsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output SSM bit position.
|
||
bit position = 4 - 8
|
||
|
||
Note: This field is only valid for E1 output module.
|
||
"
|
||
::= { setE12048oEntry 11 }
|
||
|
||
-- ******************************************
|
||
-- DS1 LRM MODULE
|
||
-- ******************************************
|
||
|
||
setLrmPTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM ports status and settings.
|
||
"
|
||
::= { setupLrm 2 }
|
||
|
||
setLrmPEntry OBJECT-TYPE
|
||
SYNTAX SetLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 LRM attributes.
|
||
"
|
||
INDEX { setLrmPChassis, setLrmPSlot, setLrmPPort}
|
||
::= { setLrmPTable 1 }
|
||
|
||
SetLrmPEntry ::=
|
||
SEQUENCE {
|
||
setLrmPChassis
|
||
INTEGER,
|
||
setLrmPSlot
|
||
INTEGER,
|
||
setLrmPPort
|
||
INTEGER,
|
||
setLrmPEnable
|
||
OnValue,
|
||
setLrmPLbo
|
||
INTEGER,
|
||
setLrmPSlip
|
||
INTEGER,
|
||
setLrmPBpv
|
||
INTEGER,
|
||
setLrmPFlt
|
||
INTEGER,
|
||
setLrmPCid
|
||
DisplayString
|
||
}
|
||
|
||
setLrmPChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 1 }
|
||
|
||
setLrmPSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 2 }
|
||
|
||
setLrmPPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 3 }
|
||
|
||
setLrmPEnable OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the LRM ports to enabled or disabled.
|
||
"
|
||
::= { setLrmPEntry 4 }
|
||
|
||
setLrmPLbo OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
lbo133ft(1),
|
||
lbo266ft(2),
|
||
lbo399ft(3),
|
||
lbo533ft(4),
|
||
lbo655ft(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Line Build-Out for the LRM port.
|
||
1=lbo133ft
|
||
2=lbo266ft
|
||
3=lbo399ft
|
||
4=lbo533ft
|
||
5=lbo655ft
|
||
"
|
||
::= { setLrmPEntry 5 }
|
||
|
||
setLrmPSlip OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
|
||
"
|
||
::= { setLrmPEntry 6 }
|
||
|
||
setLrmPBpv OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear the accumulated BPV errors
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
"
|
||
::= { setLrmPEntry 7 }
|
||
|
||
setLrmPFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
squelch(1),
|
||
ais(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Side 1 fault strategy
|
||
"
|
||
::= { setLrmPEntry 8 }
|
||
|
||
setLrmPCid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..43))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the circuit id for LRM port
|
||
The circuit id is an 0-43 character string with all ascii printable characters.
|
||
"
|
||
::= { setLrmPEntry 9 }
|
||
|
||
|
||
-- ******************************************
|
||
-- E1 LRM MODULE
|
||
-- ******************************************
|
||
|
||
setLrme1PTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM ports status and settings.
|
||
"
|
||
::= { setupLrmE1 2 }
|
||
|
||
setLrme1PEntry OBJECT-TYPE
|
||
SYNTAX SetLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 LRM attributes.
|
||
"
|
||
INDEX { setLrme1PChassis, setLrme1PSlot, setLrme1PPort}
|
||
::= { setLrme1PTable 1 }
|
||
|
||
SetLrme1PEntry ::=
|
||
SEQUENCE {
|
||
setLrme1PChassis
|
||
INTEGER,
|
||
setLrme1PSlot
|
||
INTEGER,
|
||
setLrme1PPort
|
||
INTEGER,
|
||
setLrme1PEnable
|
||
OnValue,
|
||
setLrme1PSlip
|
||
INTEGER,
|
||
setLrme1PBpv
|
||
INTEGER,
|
||
setLrme1PFlt
|
||
INTEGER,
|
||
setLrme1PCid
|
||
DisplayString
|
||
}
|
||
|
||
setLrme1PChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 1 }
|
||
|
||
setLrme1PSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 2 }
|
||
|
||
setLrme1PPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 3 }
|
||
|
||
setLrme1PEnable OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the LRM ports to enabled or disabled.
|
||
"
|
||
::= { setLrme1PEntry 4 }
|
||
|
||
setLrme1PSlip OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
|
||
"
|
||
::= { setLrme1PEntry 5 }
|
||
|
||
setLrme1PBpv OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear the accumulated BPV errors
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
"
|
||
::= { setLrme1PEntry 6 }
|
||
|
||
setLrme1PFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
squelch(1),
|
||
ais(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Side 1 fault strategy
|
||
"
|
||
::= { setLrme1PEntry 7 }
|
||
|
||
setLrme1PCid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..43))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the circuit id for LRM port
|
||
The circuit id is an 0-43 character string with all ascii printable characters.
|
||
"
|
||
::= { setLrme1PEntry 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- JAPANESE SINE OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setSineoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSineoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine output status and settings.
|
||
"
|
||
::= { setupSineOut 2 }
|
||
|
||
setSineoEntry OBJECT-TYPE
|
||
SYNTAX SetSineoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 LRM attributes.
|
||
"
|
||
INDEX { setSineoChassis, setSineoSlot}
|
||
::= { setSineoTable 1 }
|
||
|
||
SetSineoEntry ::=
|
||
SEQUENCE {
|
||
setSineoChassis
|
||
INTEGER,
|
||
setSineoSlot
|
||
INTEGER,
|
||
setSineoBypass
|
||
OnValue,
|
||
setSineoFrequency
|
||
INTEGER,
|
||
setSineoEnable
|
||
OCTET STRING,
|
||
setSineoSquelch
|
||
OCTET STRING
|
||
}
|
||
|
||
setSineoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineoEntry 1 }
|
||
|
||
setSineoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineoEntry 2 }
|
||
|
||
setSineoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setSineoEntry 3 }
|
||
|
||
setSineoFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (1544|6312)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output frequency 1.544 or 6.312 MHz.
|
||
"
|
||
::= { setSineoEntry 4 }
|
||
|
||
setSineoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setSineoEntry 5 }
|
||
|
||
setSineoSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PQL threshold to turn port off.
|
||
If the system PQL is below the PWL threshold the port is turned off (i.e. squelched).
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The PQL value of each byte defined as follows:
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
"
|
||
::= { setSineoEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- 64+8+4 (JAPANESE) CC OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setJccoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetJccoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of JCC output status and settings.
|
||
"
|
||
::= { setupJccOut 2 }
|
||
|
||
setJccoEntry OBJECT-TYPE
|
||
SYNTAX SetJccoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set JCC output attributes.
|
||
"
|
||
INDEX { setJccoChassis, setJccoSlot}
|
||
::= { setJccoTable 1 }
|
||
|
||
SetJccoEntry ::=
|
||
SEQUENCE {
|
||
setJccoChassis
|
||
INTEGER,
|
||
setJccoSlot
|
||
INTEGER,
|
||
setJccoBypass
|
||
OnValue,
|
||
setJcco400Hz
|
||
OnValue,
|
||
setJccoEnable
|
||
OCTET STRING,
|
||
setJccoComp
|
||
OCTET STRING
|
||
}
|
||
|
||
setJccoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each JCC Output entry.
|
||
"
|
||
::= { setJccoEntry 1 }
|
||
|
||
setJccoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each JCC Output entry.
|
||
"
|
||
::= { setJccoEntry 2 }
|
||
|
||
setJccoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setJccoEntry 3 }
|
||
|
||
setJcco400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the 400Hz BPV removal.
|
||
A setting OFF removes this 400Hz component, and a setting ON includes it.
|
||
"
|
||
::= { setJccoEntry 4 }
|
||
|
||
setJccoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the JCC output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setJccoEntry 5 }
|
||
|
||
|
||
setJccoComp OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The array represents the output phase compensation
|
||
for all ports on an output module.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The specifed byte value is 1 thru 8.
|
||
1 = no delay, 8 = highest delay.
|
||
|
||
The equivalent cable length:
|
||
1 = 2200 ft,
|
||
2 = 1925 ft,
|
||
3 = 1650 ft,
|
||
4 = 1375 ft,
|
||
5 = 1100 ft,
|
||
6 = 825 ft,
|
||
7 = 550 ft,
|
||
8 = 275 ft.
|
||
"
|
||
::= { setJccoEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP status and settings.
|
||
"
|
||
::= { setupPtNtp 1 }
|
||
|
||
|
||
setPtNtpEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP settings and attributes.
|
||
"
|
||
INDEX { setPtNtpChassis, setPtNtpSlot}
|
||
::= { setPtNtpTable 1 }
|
||
|
||
SetPtNtpEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpChassis
|
||
INTEGER,
|
||
setPtNtpSlot
|
||
INTEGER,
|
||
setPtNtpCommit
|
||
INTEGER,
|
||
setPtNtpProbe
|
||
EnaValue,
|
||
setPtNtpBond
|
||
EnaValue,
|
||
setPtNtpNTPd
|
||
EnaValue,
|
||
setPtNtpTodsrcPrefer
|
||
INTEGER,
|
||
setPtNtpTodsrcPriority
|
||
INTEGER,
|
||
setPtNtpWeight
|
||
INTEGER,
|
||
setPtNtpCompensation
|
||
INTEGER,
|
||
setPtNtpPeerTimeout
|
||
INTEGER,
|
||
setPtNtpPeerPrefer
|
||
INTEGER,
|
||
setPtNtpBypass
|
||
OnValue,
|
||
setPtNtpModActive
|
||
YesValue,
|
||
setPtNtpPAActive
|
||
YesValue,
|
||
setPtNtpPBActive
|
||
YesValue
|
||
}
|
||
|
||
setPtNtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpEntry 1 }
|
||
|
||
setPtNtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpEntry 2 }
|
||
|
||
setPtNtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Commit all provisioned parameters, this action makes the parameters active.
|
||
This command will also store the parameters to non-volatile memory.
|
||
|
||
Note: This field only has meaning for a writing (1).
|
||
"
|
||
::= { setPtNtpEntry 3 }
|
||
|
||
setPtNtpProbe OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PackeTime Maintenance Port state; Enable or Disable.
|
||
|
||
This node is obsolete, The setting is NOP.
|
||
"
|
||
::= { setPtNtpEntry 4 }
|
||
|
||
|
||
setPtNtpBond OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Service port bonding state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpEntry 5 }
|
||
|
||
setPtNtpNTPd OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the NTP daemon state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpEntry 6 }
|
||
|
||
setPtNtpTodsrcPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
todsrc(1),
|
||
peer(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module's preferred time-source to be either TODSRC (1) or PEER (2).
|
||
TOD Source, either the TODSRC (GPS) or a NTP Peer if operating in Client mode
|
||
"
|
||
::= { setPtNtpEntry 7 }
|
||
|
||
setPtNtpTodsrcPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Todsrc priority.
|
||
The priority is the for the specified module as the TOD Source,
|
||
default is 0, range can be 0 through 8. Value 1 is the highest,
|
||
and 8 is the lowest. If the value is zero, the specified module
|
||
cannot be TOD Source.
|
||
"
|
||
::= { setPtNtpEntry 8 }
|
||
|
||
setPtNtpWeight OBJECT-TYPE
|
||
SYNTAX INTEGER (-1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the load distribution between portA/B in percent.
|
||
For example, 70 means port-A get 70% of total bandwidth,
|
||
port-B gets remaining 30%. If port-A reaches 70% of total
|
||
bandwidth but port-B has no traffic, the 30% of bandwidth
|
||
will be wasted, port-A cannot use it. To allow either port
|
||
to use all the bandwidth, portAWeight can be set to -1,
|
||
indicating no limit between port-A and port-B (either port-A
|
||
or port-B can get all the bandwidth, based on first come
|
||
first serve). Thus the range of this parameter -1 to 100.
|
||
For bonding mode, this parameter must be forced to -1,
|
||
so the active port can use 100% of the bandwidth.
|
||
For non-bonding mode, user can set any value between -1 to 100.
|
||
"
|
||
::= { setPtNtpEntry 9 }
|
||
|
||
setPtNtpCompensation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..250)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Antenna cable delay compensation
|
||
in the case of GPS ToD Source(s) or the delay induced by the cable(s) used to connect
|
||
expansion shelves where the PackeTime ToD Source(s) is located in relationship to the Main shelf.
|
||
The time offset shall have a 100nS resolution, thus the Delay value shall be multiplied
|
||
by 100nS to provide 1PPS compensation.
|
||
Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
|
||
"
|
||
::= { setPtNtpEntry 10 }
|
||
|
||
setPtNtpPeerTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Peer Availability Timeout
|
||
The timer shall have a user settable range from 60 minutes to 10000 minutes,
|
||
with a default value of 1440 minutes
|
||
"
|
||
::= { setPtNtpEntry 11 }
|
||
|
||
setPtNtpPeerPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the preferred peer from the peer list.
|
||
The valid value is 0-8. The value zero means, there is no prefer.
|
||
This value has meaning, only when the specified peer is in the peer list.
|
||
"
|
||
::= { setPtNtpEntry 12 }
|
||
|
||
setPtNtpBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock C state, or bypass clock, to enabled or disabled.
|
||
"
|
||
::= { setPtNtpEntry 13 }
|
||
|
||
setPtNtpModActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified module in the redundant pair to be Active.
|
||
Note1: This command only applies when the module in the redundant pair.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 14 }
|
||
|
||
setPtNtpPAActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Port A is being manually selected as the active port.
|
||
Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 15 }
|
||
|
||
setPtNtpPBActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Port B is being manually selected as the active port.
|
||
Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 16 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE PORT SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP ethernet port information.
|
||
"
|
||
::= { setupPtNtp 2 }
|
||
|
||
|
||
setPtNtpPortEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP ethernet port state and settings information.
|
||
setPtNtpPortChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpPortSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpPortNum
|
||
Identifies which port is being addressed.
|
||
setPtNtpPortAddr
|
||
Set the port IP address
|
||
setPtNtpPortMask
|
||
Set the port network mask
|
||
setPtNtpPortGate
|
||
Set the port gateway address
|
||
"
|
||
INDEX { setPtNtpPortChassis, setPtNtpPortSlot, setPtNtpPortNum}
|
||
::= { setPtNtpPortTable 1 }
|
||
|
||
SetPtNtpPortEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpPortChassis
|
||
INTEGER,
|
||
setPtNtpPortSlot
|
||
INTEGER,
|
||
setPtNtpPortNum
|
||
INTEGER,
|
||
setPtNtpPortAddr
|
||
IpAddress,
|
||
setPtNtpPortMask
|
||
IpAddress,
|
||
setPtNtpPortGate
|
||
IpAddress
|
||
}
|
||
|
||
setPtNtpPortChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPortEntry 1 }
|
||
|
||
setPtNtpPortSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPortEntry 2 }
|
||
|
||
setPtNtpPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
|
||
PTNTP ethernet interface number.
|
||
1 = Service Port A
|
||
2 = Service Port B
|
||
3 = Maintenance Port
|
||
"
|
||
::= { setPtNtpPortEntry 3 }
|
||
|
||
setPtNtpPortAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port IP address
|
||
"
|
||
::= { setPtNtpPortEntry 4 }
|
||
|
||
setPtNtpPortMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port network mask
|
||
"
|
||
::= { setPtNtpPortEntry 5 }
|
||
|
||
setPtNtpPortGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port gateway address
|
||
"
|
||
::= { setPtNtpPortEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE PEER SETUP GROUP
|
||
-- EXTERNAL NTP SERVER
|
||
-- ******************************************
|
||
|
||
setPtNtpPeerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpPeerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime NTP Peer entries.
|
||
Entries are indexed by the values of setPtNtpPeerChassis, setPtNtpPeerSlot and setPtNtpPortNum.
|
||
"
|
||
::= { setupPtNtp 3 }
|
||
|
||
setPtNtpPeerEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpPeerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime NTP peer state and settings.
|
||
setPtNtpPeerChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpPeerSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpPeerNum
|
||
Identifies which ntp peer is being addressed.
|
||
setPtNtpPeerAddr
|
||
Set Peer IP address in peer table.
|
||
setPtNtpPeerPmin
|
||
Set the minimum request rate in seconds for CLIENT mode.
|
||
setPtNtpPeerPmax
|
||
Set the maximum request rate in seconds for CLIENT mode.
|
||
setPtNtpPeerKeyId
|
||
Set keyId to be used to lookup authentication key,
|
||
"
|
||
INDEX { setPtNtpPeerChassis, setPtNtpPeerSlot, setPtNtpPeerNum}
|
||
::= { setPtNtpPeerTable 1 }
|
||
|
||
SetPtNtpPeerEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpPeerChassis
|
||
INTEGER,
|
||
setPtNtpPeerSlot
|
||
INTEGER,
|
||
setPtNtpPeerNum
|
||
INTEGER,
|
||
setPtNtpPeerAddr
|
||
IpAddress,
|
||
setPtNtpPeerPmin
|
||
INTEGER,
|
||
setPtNtpPeerPmax
|
||
INTEGER,
|
||
setPtNtpPeerKeyId
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpPeerChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 1 }
|
||
|
||
setPtNtpPeerSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 2 }
|
||
|
||
setPtNtpPeerNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which ntp peer is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 3 }
|
||
|
||
setPtNtpPeerAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Peer IP address in peer table.
|
||
Write zero IP address will delete this IP address from peer table.
|
||
"
|
||
::= { setPtNtpPeerEntry 4 }
|
||
|
||
setPtNtpPeerPmin OBJECT-TYPE
|
||
SYNTAX INTEGER (16|32|64|128|256|512|1024)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum request rate in seconds for CLIENT mode,
|
||
the default is 16, the range is 16, 32, 64, 128, 256, 512, and 1024.
|
||
"
|
||
::= { setPtNtpPeerEntry 5 }
|
||
|
||
setPtNtpPeerPmax OBJECT-TYPE
|
||
SYNTAX INTEGER (16|32|64|128|256|512|1024)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the maximum request rate in seconds for CLIENT mode,
|
||
the default is 64, the range is 16, 32, 64, 128, 256, 512, and 1024.
|
||
"
|
||
::= { setPtNtpPeerEntry 6 }
|
||
|
||
setPtNtpPeerKeyId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65534)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set keyId to be used to lookup authentication key,
|
||
the default is 0 (no authentication), the range is 0 through 65534
|
||
"
|
||
::= { setPtNtpPeerEntry 7 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE AUTH SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpAuthTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpAuthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP authentication entries.
|
||
The number of entries are given by the values of setPtNtpAuthChassis, setPtNtpAuthSlot and setPtNtpAuthNum.
|
||
"
|
||
::= { setupPtNtp 4 }
|
||
|
||
setPtNtpAuthEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpAuthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime NTP authentication state and settings.
|
||
PackeTime NTP authentication attributes.
|
||
setPtNtpAuthChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpAuthSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpAuthNum
|
||
Identifies which authentication key is being addressed.
|
||
setPtNtpAuthKeyId
|
||
Set the authentication key ID,
|
||
setPtNtpAuthKeyValue
|
||
Set the NTP authentication key used to create the MD5 hash associated with the keyid.
|
||
"
|
||
INDEX { setPtNtpAuthChassis, setPtNtpAuthSlot, setPtNtpAuthNum}
|
||
::= { setPtNtpAuthTable 1 }
|
||
|
||
SetPtNtpAuthEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpAuthChassis
|
||
INTEGER,
|
||
setPtNtpAuthSlot
|
||
INTEGER,
|
||
setPtNtpAuthNum
|
||
INTEGER,
|
||
setPtNtpAuthKeyId
|
||
INTEGER,
|
||
setPtNtpAuthKeyValue
|
||
DisplayString
|
||
}
|
||
|
||
setPtNtpAuthChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 1 }
|
||
|
||
setPtNtpAuthSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 2 }
|
||
|
||
setPtNtpAuthNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which authentication key is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 3 }
|
||
|
||
setPtNtpAuthKeyId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65534)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set KeyId is the authentication key ID,
|
||
default is 0 (no authentication), range 0 to 65534.
|
||
Note: If this value is zero, no authentication is used.
|
||
"
|
||
::= { setPtNtpAuthEntry 4 }
|
||
|
||
setPtNtpAuthKeyValue OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0|8..32))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the key is the NTP authentication key used to create the MD5 hash associated with the keyid.
|
||
The key is a comprised of up to 32 ASCII characters, a minimum of 8 characters is required.
|
||
Note: the key value will not display and it is always displayed as null string.
|
||
"
|
||
::= { setPtNtpAuthEntry 5 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE ROUTE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpRouteTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpRouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP route table entries.
|
||
|
||
Static routing describes a system that does not implement adaptive routing. In these systems routes through a data
|
||
network are described by fixed paths (statically). These routes are usually entered into the host by the system
|
||
administrator.
|
||
"
|
||
::= { setupPtNtp 5 }
|
||
|
||
setPtNtpRouteEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpRouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime NTP route attributes and settings.
|
||
setPtNtpRouteChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpRouteSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpRouteNum
|
||
Identifies which route number (index) is being addressed.
|
||
setPtNtpRouteAddr
|
||
Set the route destination network or destination host.
|
||
setPtNtpRouteMask
|
||
Set the netmask for the destination network.
|
||
setPtNtpRouteGate
|
||
Set the gateway ip for the destination network.
|
||
setPtNtpRouteIface
|
||
Set the module's network interface number.
|
||
"
|
||
INDEX { setPtNtpRouteChassis, setPtNtpRouteSlot, setPtNtpRouteNum}
|
||
::= { setPtNtpRouteTable 1 }
|
||
|
||
SetPtNtpRouteEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpRouteChassis
|
||
INTEGER,
|
||
setPtNtpRouteSlot
|
||
INTEGER,
|
||
setPtNtpRouteNum
|
||
INTEGER,
|
||
setPtNtpRouteAddr
|
||
IpAddress,
|
||
setPtNtpRouteMask
|
||
IpAddress,
|
||
setPtNtpRouteGate
|
||
IpAddress,
|
||
setPtNtpRouteIface
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpRouteChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 1 }
|
||
|
||
setPtNtpRouteSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 2 }
|
||
|
||
setPtNtpRouteNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which route number is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 3 }
|
||
|
||
setPtNtpRouteAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the route destination network or destination host.
|
||
Write a new Route IP address will put this new IP into table.
|
||
Write zero IP address will delete this IP address from table.
|
||
"
|
||
::= { setPtNtpRouteEntry 4 }
|
||
|
||
setPtNtpRouteMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the netmask for the destination network;
|
||
'255.255.255.255' for a host destination and
|
||
'0.0.0.0' for the default route
|
||
"
|
||
::= { setPtNtpRouteEntry 5 }
|
||
|
||
setPtNtpRouteGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the gateway for the destination network.
|
||
"
|
||
::= { setPtNtpRouteEntry 6 }
|
||
|
||
setPtNtpRouteIface OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module's network interface number:
|
||
1 = Service Port A
|
||
2 = Service Port B
|
||
3 = Bond0 (bonding of PortA and Port B)
|
||
"
|
||
::= { setPtNtpRouteEntry 7 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE VLAN SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpVlanTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime NTP vlan attributes.
|
||
The Virtural Local Area Network is implemented per IEEE 802.1Q.
|
||
"
|
||
::= { setupPtNtp 6 }
|
||
|
||
|
||
setPtNtpVlanEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime NTP vlan attributes and settings:
|
||
setPtNtpVlanChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpVlanSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpVlan
|
||
Set the VLAN state.
|
||
setPtNtpVlanPAId
|
||
Set the VLAN ID for Service Port A.
|
||
setPtNtpVlanPAPriority
|
||
Set the VLAN priority for Service Port A.
|
||
setPtNtpVlanPBId
|
||
Set the VLAN ID for Service Port B.
|
||
setPtNtpVlanPBPriority
|
||
Set the VLAN priority for Service Port B.
|
||
setPtNtpVlanBondId
|
||
Set the VLAN ID for Bonding of Service Ports of A and B
|
||
setPtNtpVlanBondPriority
|
||
Set the VLAN priority for Bonding of Service Ports of A and B
|
||
"
|
||
INDEX { setPtNtpVlanChassis, setPtNtpVlanSlot}
|
||
::= { setPtNtpVlanTable 1 }
|
||
|
||
SetPtNtpVlanEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpVlanChassis
|
||
INTEGER,
|
||
setPtNtpVlanSlot
|
||
INTEGER,
|
||
setPtNtpVlan
|
||
EnaValue,
|
||
setPtNtpVlanPAId
|
||
INTEGER,
|
||
setPtNtpVlanPAPriority
|
||
INTEGER,
|
||
setPtNtpVlanPBId
|
||
INTEGER,
|
||
setPtNtpVlanPBPriority
|
||
INTEGER,
|
||
setPtNtpVlanBondId
|
||
INTEGER,
|
||
setPtNtpVlanBondPriority
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpVlanChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpVlanEntry 1 }
|
||
|
||
setPtNtpVlanSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpVlanEntry 2 }
|
||
|
||
setPtNtpVlan OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpVlanEntry 3 }
|
||
|
||
setPtNtpVlanPAId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Service Port A, [0 - 4094]
|
||
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 4 }
|
||
|
||
setPtNtpVlanPAPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Service Port A, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 5 }
|
||
|
||
setPtNtpVlanPBId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Service Port B, [0 - 4094]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 6 }
|
||
|
||
|
||
setPtNtpVlanPBPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Service Port B, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 7 }
|
||
|
||
setPtNtpVlanBondId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Bonding of Service Ports of A and B, [0 - 4094]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 8 }
|
||
|
||
|
||
setPtNtpVlanBondPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Bonding of Service Ports of A and B, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 9 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 GENERAL INFORMATION GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
infoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF GiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of general information entries."
|
||
::= { general 1 }
|
||
|
||
|
||
giEntry OBJECT-TYPE
|
||
SYNTAX GiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set global module attributes.
|
||
"
|
||
INDEX { giChassis, giSlot }
|
||
::= { infoTable 1 }
|
||
|
||
|
||
GiEntry ::=
|
||
SEQUENCE {
|
||
giChassis
|
||
INTEGER,
|
||
giSlot
|
||
INTEGER,
|
||
giSystime
|
||
Counter32,
|
||
giElevation
|
||
INTEGER,
|
||
giSetup
|
||
INTEGER,
|
||
giRestart
|
||
YesValue
|
||
}
|
||
|
||
giChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { giEntry 1 }
|
||
|
||
giSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { giEntry 2 }
|
||
|
||
giSystime OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) a specified module has been operational since last reboot.
|
||
Only apply to the CPU-based module. zero means Not Applicable.
|
||
"
|
||
::= { giEntry 3 }
|
||
|
||
giElevation OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 60..500000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The module alarm elevation time (in seconds).
|
||
Each module in the system can be set for elevation time from 60 seconds to 500,000 seconds.
|
||
A setting of 0 (zero) means no elevation for the alarm.
|
||
For example, when an alarm has been at MINOR level ontinuously for elevtime seconds, then it is elevated to the next level (MAJOR).
|
||
|
||
Note: 0 = disabled.
|
||
"
|
||
::= { giEntry 4 }
|
||
|
||
|
||
giSetup OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
factory(1),
|
||
user(2),
|
||
save(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Saves or restores the configuration of the specified module.
|
||
|
||
FACTORY - restores the module configuration to factory defaults.
|
||
SAVE - will save the current configuration as User.
|
||
USER - will restore the saved User configuration.
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
Only apply to the CPU-based module.
|
||
"
|
||
::= { giEntry 5 }
|
||
|
||
|
||
giRestart OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Restarts a module.
|
||
Writing a '1' to this variable restarts (reboots) the module.
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
Only apply to the CPU-based module.
|
||
"
|
||
::= { giEntry 6 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MODULE EVENT GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
evCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports total number of events to display.
|
||
The number represents total number of events
|
||
we want to display. Its value ranges between
|
||
1 and 1000.
|
||
"
|
||
::= { event 1 }
|
||
|
||
evType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
alarm(1),
|
||
report(2),
|
||
all(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which event type we want to display (functions as a display filter).
|
||
Set these values to the desired type you want to display:
|
||
ALARM - for alarm type
|
||
REPORT - for event type
|
||
ALL - for all (alarm and event) type.
|
||
"
|
||
::= { event 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- EVENT TABLE
|
||
-- ******************************************
|
||
|
||
eventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF EvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report of system event entries.
|
||
The number of entries is given by the value of evNumber.
|
||
The total entries are up to 1000."
|
||
::= { event 3 }
|
||
|
||
|
||
evEntry OBJECT-TYPE
|
||
SYNTAX EvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An event entry containing objects of each event."
|
||
INDEX { evIndex }
|
||
::= { eventTable 1 }
|
||
|
||
|
||
EvEntry ::=
|
||
SEQUENCE {
|
||
evIndex
|
||
INTEGER,
|
||
evT
|
||
OCTET STRING
|
||
}
|
||
|
||
evIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each event.
|
||
This value range from 1 to 1000."
|
||
::= { evEntry 1 }
|
||
|
||
|
||
evT OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(36..116))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A OCTET STRING containing information about the event.
|
||
|
||
The string is in the TLV format, and contains
|
||
following information:
|
||
INTEGER - event id
|
||
INTEGER - module hex code
|
||
DateAndTime - timestamp
|
||
INTEGER - chassis number
|
||
INTEGER - slot number
|
||
INTEGER - port number
|
||
INTEGER - alarm code
|
||
INTEGER - notification code
|
||
INTEGER - Elevated
|
||
DisplayString - ascii string description of the event
|
||
|
||
event id:
|
||
INTEGER (0..255)
|
||
|
||
Alarm Code:
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
|
||
Notification Code:
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
|
||
Elevated:
|
||
Yes(1),
|
||
No(2)
|
||
"
|
||
::= { evEntry 2 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 ALARM GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- ALARM STATUS TABLE
|
||
-- **************************************************************
|
||
|
||
alarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of alarm entries.
|
||
"
|
||
::= { alarm 1 }
|
||
|
||
almEntry OBJECT-TYPE
|
||
SYNTAX AlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm entry attributes.
|
||
"
|
||
INDEX { almChassis, almSlot, almPort, almIndex }
|
||
::= { alarmTable 1 }
|
||
|
||
AlmEntry ::=
|
||
SEQUENCE {
|
||
almChassis
|
||
INTEGER,
|
||
almSlot
|
||
INTEGER,
|
||
almPort
|
||
INTEGER,
|
||
almIndex
|
||
INTEGER,
|
||
almId
|
||
INTEGER,
|
||
almName
|
||
DisplayString,
|
||
almLevel
|
||
INTEGER,
|
||
almElevate
|
||
YesValue,
|
||
almStatus
|
||
DisplayString
|
||
}
|
||
|
||
almChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 1 }
|
||
|
||
almSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 2 }
|
||
|
||
|
||
almPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 3 }
|
||
|
||
almIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the alarm index value.
|
||
|
||
Note: The alarm id is allowed for number zero; therefore,
|
||
the OID for this index is alarm id plus 1 to avoid the zero number for OID.
|
||
"
|
||
::= { almEntry 4 }
|
||
|
||
almId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..31)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the alarm id.
|
||
|
||
Note: This is the actual alarm id range 0 thru 31.
|
||
"
|
||
::= { almEntry 5 }
|
||
|
||
almName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the text string to describe this alarm.
|
||
"
|
||
::= { almEntry 6 }
|
||
|
||
almLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current state of alarm indications on the units.
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
"
|
||
::= { almEntry 7 }
|
||
|
||
|
||
almElevate OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report alarm elevation state
|
||
|
||
1 = alarm elevated
|
||
2 = alarm not elevated
|
||
"
|
||
::= { almEntry 8 }
|
||
|
||
almStatus OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the text string to describe this alarm status condition.
|
||
"
|
||
::= { almEntry 9 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- ALARM SET GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
--
|
||
-- MODULE ALARM SETTING
|
||
-- IT SHOULD BE ONE MODULE, MULTIPLE MODULE IS NOT ALLOWED
|
||
|
||
setAlmLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module slot location.
|
||
It should be one module, multiple module is not allowed
|
||
where
|
||
x is the chassis number: the range is 1 to 5,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number. range is [1 to 20].
|
||
|
||
For example: 1A3-1 for module located in chassis 1 and slot 3, port 1.
|
||
|
||
Note: The slot location must be physically installed in the unit.
|
||
"
|
||
::= { alarm 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- ALARM SETTING TABLE
|
||
-- ******************************************
|
||
|
||
setAlmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of alarm entries.
|
||
"
|
||
::= { alarm 3 }
|
||
|
||
salEntry OBJECT-TYPE
|
||
SYNTAX SalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set alarm attributes.
|
||
"
|
||
INDEX { salChassis, salSlot, salPort, salIndex }
|
||
::= { setAlmTable 1 }
|
||
|
||
|
||
SalEntry ::=
|
||
SEQUENCE {
|
||
salChassis
|
||
INTEGER,
|
||
salSlot
|
||
INTEGER,
|
||
salPort
|
||
INTEGER,
|
||
salIndex
|
||
INTEGER,
|
||
salId
|
||
INTEGER,
|
||
salName
|
||
DisplayString,
|
||
salSet
|
||
YesValue,
|
||
salElevate
|
||
YesValue,
|
||
salLevel
|
||
INTEGER,
|
||
salDelay
|
||
INTEGER
|
||
}
|
||
|
||
salChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 1 }
|
||
|
||
salSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 2 }
|
||
|
||
|
||
salPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 3 }
|
||
|
||
salIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for the alarm.
|
||
|
||
Note: The alarm id is allowed for number zero;
|
||
therefore, the OID for this index is alarm id plus 1 to avoid the zero number for OID.
|
||
"
|
||
::= { salEntry 4 }
|
||
|
||
salId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..31)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ID value for the alarm.
|
||
|
||
Note: This is the actual alarm id range 0 thru 31.
|
||
"
|
||
::= { salEntry 5 }
|
||
|
||
salName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name/Description for the alarm.
|
||
"
|
||
::= { salEntry 6 }
|
||
|
||
salSet OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm state for the alarm:
|
||
|
||
1 = alarm set
|
||
2 = no alarm
|
||
"
|
||
::= { salEntry 7 }
|
||
|
||
salElevate OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm elevation status:
|
||
|
||
1 = alarm elevated
|
||
2 = alarm not elevated
|
||
"
|
||
::= { salEntry 8 }
|
||
|
||
salLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets alarm severe level are:
|
||
MINOR - sets alarm level to MINOR
|
||
MAJOR - set alarm level to MAJOR
|
||
CRITICAL - sets alarm level to CRITICAL
|
||
IGNORE - ignore any alarm indication
|
||
REPORT - report only any alarm indication
|
||
"
|
||
::= { salEntry 9 }
|
||
|
||
salDelay OBJECT-TYPE
|
||
SYNTAX INTEGER (-1 | 0..86400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the length of time in seconds an alarm must be active before generating an alarm.
|
||
|
||
Note:
|
||
0 = user selected immediate indication
|
||
-1 (when read) = forced immediate indication (i.e. not user selectable)
|
||
"
|
||
::= { salEntry 10 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 REF GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
refClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
none(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set which clk is currently selected.
|
||
clka(1),
|
||
clkb(2),
|
||
none(3)
|
||
|
||
Note: When read, it shows which clock is currently selected.
|
||
When write, only clka or clkb are valid.
|
||
"
|
||
::= { ref 1 }
|
||
|
||
refInp OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the input reference port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
The NULL string means there is no input reference.
|
||
"
|
||
::= { ref 2 }
|
||
|
||
refBypass OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input port designated as the input bypass clock.
|
||
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
The NULL string means there is no bypass clock.
|
||
|
||
Note: In the SSU2000, the input module always resides in the main chassis (i.e. 'x' is one).
|
||
"
|
||
::= { ref 3 }
|
||
|
||
refClkSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ar(1),
|
||
off(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set Clock auto-return (AR) mode.
|
||
ar(1),
|
||
off(2)
|
||
The AR option changes the current clock selection mode to revertive operation.
|
||
"
|
||
::= { ref 4 }
|
||
|
||
refInpSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ar(1),
|
||
as(2),
|
||
off(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input switch mode.
|
||
The InpSwitch settings are:
|
||
|
||
AR = Auto Return (revertive)
|
||
AS = Auto Switch (but not revertive)
|
||
OFF = No auto switching
|
||
"
|
||
::= { ref 5 }
|
||
|
||
refInpSelection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
priority(1),
|
||
pql(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input selection mode.
|
||
The input reference selection can be PRIORITY/ PQL.
|
||
|
||
PRIORITY - the user assigned priority number is used to
|
||
pick the best input port as an input reference.
|
||
PQL - the input Priority Quality Level (PQL) is used to
|
||
select which is the best input port reference.
|
||
"
|
||
::= { ref 6 }
|
||
|
||
refClkTodsrc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set TOD Source.
|
||
The value can be any TOD source candidate (GPS or PackeTime) indicates the TODSRC of the selected clock.
|
||
|
||
The text string of the todsrc reference port.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A3 means this reference located at chassis 1, slot 3.
|
||
The NULL string means there is no reference.
|
||
"
|
||
::= { ref 7 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 PHASE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- **************************************************************
|
||
-- CURRENT PHASE TABLE
|
||
-- **************************************************************
|
||
|
||
phaseTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of phase data entries.
|
||
"
|
||
::= { phase 1 }
|
||
|
||
|
||
phEntry OBJECT-TYPE
|
||
SYNTAX PhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Phase data entry attributes.
|
||
"
|
||
INDEX { phChassis, phSlot, phPort }
|
||
::= { phaseTable 1 }
|
||
|
||
|
||
PhEntry ::=
|
||
SEQUENCE {
|
||
phChassis
|
||
INTEGER,
|
||
phSlot
|
||
INTEGER,
|
||
phPort
|
||
INTEGER,
|
||
phA
|
||
OCTET STRING,
|
||
phB
|
||
OCTET STRING,
|
||
ph100A
|
||
OCTET STRING,
|
||
ph100B
|
||
OCTET STRING,
|
||
ph1000A
|
||
OCTET STRING,
|
||
ph1000B
|
||
OCTET STRING,
|
||
ph10000A
|
||
OCTET STRING,
|
||
ph10000B
|
||
OCTET STRING
|
||
}
|
||
|
||
phChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 1 }
|
||
|
||
phSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 2 }
|
||
|
||
phPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 3 }
|
||
|
||
phA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 4 }
|
||
|
||
phB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 5 }
|
||
|
||
|
||
ph100A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 100-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 6 }
|
||
|
||
ph100B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 100-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 7 }
|
||
|
||
ph1000A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1000-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 8 }
|
||
|
||
ph1000B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1000-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 9 }
|
||
|
||
|
||
ph10000A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 10000-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 10 }
|
||
|
||
ph10000B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 10000-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 11 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- PHASE HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS (PHASE HISTORY)
|
||
-- ******************************************
|
||
|
||
phHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port must be physically installed in the system.
|
||
|
||
Note: In the SSU2000, the input is located at main chassis, the 'x' number is always one.
|
||
"
|
||
::= { phase 2 }
|
||
|
||
phHisTimeAvg OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
t100 (100), --- 100 second time interval
|
||
t1000 (1000), --- 1000 second time interval
|
||
t10000 (10000) --- 10000 second time interval
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports time (seconds) interval of phase value.
|
||
t1 (4000 second time interval),
|
||
t100 (1000 second time interval),
|
||
t1000 (1000 second time interval),
|
||
t10000 (10000 second time interval)
|
||
|
||
Note: T1 data is only available for ports configured for this function, maximum of 5 ports.
|
||
"
|
||
::= { phase 3 }
|
||
|
||
phHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is used as the reference in the phase measurement.
|
||
"
|
||
::= { phase 4 }
|
||
|
||
phHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..7000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Count of phase measurement history requested from the phase history buffer.
|
||
The maximum phase history in buffer are:
|
||
T100 = 7000,
|
||
T1000 = 700,
|
||
T10000 = 70,
|
||
|
||
Default value = 10.
|
||
"
|
||
::= { phase 5 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PHASE HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
phHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PhHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of phase history entries. The number of entries is
|
||
given by the value of phHisCnt. The total entries
|
||
are up to 7000.
|
||
|
||
Note: this table is based upon the following values:
|
||
phHisInpLoc - the location of the input port
|
||
phHisTimeAvg - the time (seconds) interval of phase value
|
||
phHisCnt - total amount of phase history to return.
|
||
"
|
||
::= { phase 6 }
|
||
|
||
|
||
|
||
phHisEntry OBJECT-TYPE
|
||
SYNTAX PhHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A phase entry attributes:
|
||
phHisChassis
|
||
Identifies which chassis is being addressed.
|
||
phHisSlot
|
||
Identifies which slot is being addressed.
|
||
phHisPort
|
||
Identifies which port is being addressed.
|
||
phHisIndex
|
||
Count/ID value for each phase.
|
||
phHisV
|
||
Phase value in nanoseconds defined in phHisTimeAvg.
|
||
"
|
||
INDEX { phHisChassis, phHisSlot, phHisPort, phHisIndex }
|
||
::= { phHisTable 1 }
|
||
|
||
PhHisEntry ::=
|
||
SEQUENCE {
|
||
phHisChassis
|
||
INTEGER,
|
||
phHisSlot
|
||
INTEGER,
|
||
phHisPort
|
||
INTEGER,
|
||
phHisIndex
|
||
INTEGER,
|
||
phHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
|
||
phHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 1 }
|
||
|
||
phHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 2 }
|
||
|
||
phHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 3 }
|
||
|
||
phHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..7000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Count/ID value for each phase.
|
||
Valid range : 1 - 7000.
|
||
"
|
||
::= { phHisEntry 4 }
|
||
|
||
|
||
phHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Phase value in nanoseconds defined in phHisTimeAvg.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and containsfollowing information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phHisEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MTIE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- CURRENT MTIE GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
mtInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
For example: 1A3 means this input port located at chassis 1, slot 3, with all port specified.
|
||
"
|
||
::= { mtie 1 }
|
||
|
||
|
||
mtFrTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select starting time to measure the MTIE from.
|
||
|
||
Note: the default time is defined as last 24 hours from current time.
|
||
The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
|
||
"
|
||
::= { mtie 2 }
|
||
|
||
mtToTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select the stop-time to measure the MTIE.
|
||
If the 'year' field of DateAndTime is specified as zero, the default time is used.
|
||
|
||
The default mtToTime is the current time.
|
||
"
|
||
::= { mtie 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- CURRENT MTIE TABLE
|
||
-- ******************************************
|
||
|
||
mtTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF MtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report the MTIE measurement.
|
||
"
|
||
::= { mtie 5 }
|
||
|
||
mtEntry OBJECT-TYPE
|
||
SYNTAX MtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A mtie record attributes:
|
||
mtChassis
|
||
Identifies which chassis is being addressed.
|
||
mtSlot
|
||
Identifies which slot is being addressed.
|
||
mtPort
|
||
Identifies which port is being addressed.
|
||
mtA
|
||
MTIE record versus clock A.
|
||
mtB
|
||
MTIE record versus clock B.
|
||
"
|
||
INDEX { mtChassis, mtSlot, mtPort }
|
||
::= { mtTable 1 }
|
||
|
||
MtEntry ::=
|
||
SEQUENCE {
|
||
mtChassis
|
||
INTEGER,
|
||
mtSlot
|
||
INTEGER,
|
||
mtPort
|
||
INTEGER,
|
||
mtA
|
||
OCTET STRING,
|
||
mtB
|
||
OCTET STRING
|
||
}
|
||
|
||
|
||
mtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 1 }
|
||
|
||
mtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 2 }
|
||
|
||
mtPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 3 }
|
||
|
||
mtA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus clock A.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtEntry 4 }
|
||
|
||
mtB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus clock B.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- MTIE HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
mtHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select the input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port is single port and must be physically installed in the system.
|
||
Multiple ports are not valid.
|
||
"
|
||
::= { mtie 6 }
|
||
|
||
mtHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock reference used for reporting of MTIE History.
|
||
"
|
||
::= { mtie 7 }
|
||
|
||
mtHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of days of MTIE History to report.
|
||
The range = 1 - 100.
|
||
Default value for this field = 1.
|
||
"
|
||
::= { mtie 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- MTIE HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
mtHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF MtHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of mtie history entries.
|
||
|
||
Note: this table is based upon the following values:
|
||
mtHisInpLoc - the location of the input port
|
||
mtHisCnt - total number of mtie hostory want to query.
|
||
"
|
||
::= { mtie 9 }
|
||
|
||
|
||
mtHisEntry OBJECT-TYPE
|
||
SYNTAX MtHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE 24-hours history attributes.
|
||
mtHisChassis
|
||
Identifies which chassis is being addressed.
|
||
mtHisSlot
|
||
Identifies which slot is being addressed.
|
||
mtHisPort
|
||
Identifies which port is being addressed.
|
||
mtHisIndex
|
||
Index for the MTIE record.
|
||
mtHisV
|
||
MTIE record versus selected clock.
|
||
"
|
||
INDEX { mtHisChassis, mtHisSlot, mtHisPort, mtHisIndex }
|
||
::= { mtHisTable 1 }
|
||
|
||
|
||
MtHisEntry ::=
|
||
SEQUENCE {
|
||
mtHisChassis
|
||
INTEGER,
|
||
mtHisSlot
|
||
INTEGER,
|
||
mtHisPort
|
||
INTEGER,
|
||
mtHisIndex
|
||
INTEGER,
|
||
mtHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
mtHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 1 }
|
||
|
||
mtHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 2 }
|
||
|
||
mtHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 3 }
|
||
|
||
mtHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for the MTIE record.
|
||
Valid range = 1 - 100.
|
||
"
|
||
::= { mtHisEntry 4 }
|
||
|
||
|
||
mtHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus selected clock.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtHisEntry 5 }
|
||
|
||
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TDEV GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- CURRENT TDEV GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
tdInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
For example: 1A3 means this input port located at hassis 1, slot 3, with all port specified.
|
||
"
|
||
::= { tdev 1 }
|
||
|
||
tdFrTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select starting time to measure the TDEV from.
|
||
|
||
Note: the default time is defined as last 24 hours from current time.
|
||
The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
|
||
"
|
||
::= { tdev 2 }
|
||
|
||
tdToTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select stop time to measure the TDEV from.
|
||
|
||
Note: the default time is the current time.
|
||
"
|
||
::= { tdev 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- CURRENT TDEV TABLE
|
||
-- ******************************************
|
||
|
||
tdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report the TDEV measurement.
|
||
"
|
||
::= { tdev 5 }
|
||
|
||
tdEntry OBJECT-TYPE
|
||
SYNTAX TdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A mtie record attributes:
|
||
tdChassis
|
||
Identifies which chassis is being addressed.
|
||
tdSlot
|
||
Identifies which slot is being addressed.
|
||
tdPort
|
||
Identifies which port is being addressed.
|
||
tdA
|
||
TDEV record versus clock A.
|
||
tdB
|
||
TDEV record versus clock B.
|
||
"
|
||
INDEX { tdChassis, tdSlot, tdPort }
|
||
::= { tdTable 1 }
|
||
|
||
TdEntry ::=
|
||
SEQUENCE {
|
||
tdChassis
|
||
INTEGER,
|
||
tdSlot
|
||
INTEGER,
|
||
tdPort
|
||
INTEGER,
|
||
tdA
|
||
OCTET STRING,
|
||
tdB
|
||
OCTET STRING
|
||
}
|
||
|
||
tdChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 1 }
|
||
|
||
tdSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 2 }
|
||
|
||
tdPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 3 }
|
||
|
||
|
||
tdA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus clock A:
|
||
|
||
TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdEntry 4 }
|
||
|
||
tdB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus clock B:
|
||
|
||
TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- TDEV HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
tdHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selected input port.
|
||
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port is single port and must be physically installed in the system.
|
||
Multiple ports are not valid.
|
||
"
|
||
::= { tdev 6 }
|
||
|
||
tdHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set which clock is used to make the TDEV measurement.
|
||
"
|
||
::= { tdev 7 }
|
||
|
||
tdHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the number of days of TDEV History to report.
|
||
The range = 1 - 100.
|
||
Default value for this field = 1.
|
||
"
|
||
::= { tdev 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- TDEV HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
tdHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TdHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of tdev history entries.
|
||
|
||
Note: this table is based upon the following values:
|
||
tdHisInpLoc - the location of the input port
|
||
tdHisCnt - total number of tdev hostory want to query.
|
||
"
|
||
::= { tdev 9 }
|
||
|
||
|
||
tdHisEntry OBJECT-TYPE
|
||
SYNTAX TdHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV 24-hours history attributes.
|
||
tdHisChassis
|
||
Identifies which chassis is being addressed.
|
||
tdHisSlot
|
||
Identifies which slot is being addressed.
|
||
tdHisPort
|
||
Identifies which port is being addressed.
|
||
tdHisIndex
|
||
Index for the TDEV record.
|
||
tdHisV
|
||
TDEV record versus selected clock.
|
||
"
|
||
INDEX { tdHisChassis, tdHisSlot, tdHisPort, tdHisIndex }
|
||
::= { tdHisTable 1 }
|
||
|
||
|
||
TdHisEntry ::=
|
||
SEQUENCE {
|
||
tdHisChassis
|
||
INTEGER,
|
||
tdHisSlot
|
||
INTEGER,
|
||
tdHisPort
|
||
INTEGER,
|
||
tdHisIndex
|
||
INTEGER,
|
||
tdHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
tdHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 1 }
|
||
|
||
tdHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 2 }
|
||
|
||
tdHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 3 }
|
||
|
||
tdHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for the TDEV history record.
|
||
Valid range = 1 - 100.
|
||
"
|
||
::= { tdHisEntry 4 }
|
||
|
||
|
||
tdHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus selected clock.
|
||
|
||
The TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdHisEntry 5 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 FREQ GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
freqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF FqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of frequency entries for each input port.
|
||
"
|
||
::= { freq 1 }
|
||
|
||
|
||
fqEntry OBJECT-TYPE
|
||
SYNTAX FqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Frequency entry attributes:
|
||
fqChassis
|
||
INTEGER,
|
||
fqSlot
|
||
INTEGER,
|
||
fqPort
|
||
INTEGER,
|
||
fqA
|
||
OCTET STRING,
|
||
fqB
|
||
"
|
||
INDEX { fqChassis, fqSlot, fqPort }
|
||
::= { freqTable 1 }
|
||
|
||
|
||
FqEntry ::=
|
||
SEQUENCE {
|
||
fqChassis
|
||
INTEGER,
|
||
fqSlot
|
||
INTEGER,
|
||
fqPort
|
||
INTEGER,
|
||
fqA
|
||
OCTET STRING,
|
||
fqB
|
||
OCTET STRING
|
||
}
|
||
|
||
fqChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 1 }
|
||
|
||
fqSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 2 }
|
||
|
||
fqPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 3 }
|
||
|
||
|
||
fqA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current frequency measurement versus clock A.
|
||
The 1,999,999,999 is designated for invalid frequency value.
|
||
|
||
DateAndTime - timestamp
|
||
INTEGER - frequency value
|
||
"
|
||
::= { fqEntry 4 }
|
||
|
||
fqB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current frequency measurement versus clock B.
|
||
The 1,999,999,999 is designated for invalid frequency value.
|
||
|
||
DateAndTime - timestamp
|
||
INTEGER - frequency value
|
||
"
|
||
::= { fqEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
server(1),
|
||
client(2),
|
||
local(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current NTP mode in the system.
|
||
|
||
SERVER - The system has a GPS module installed and has UTC time.
|
||
|
||
CLIENT - The system has a valid Client peer entry in the NTP Table,
|
||
and is synced with its associated Server.
|
||
|
||
LOCAL - The sytem is running its own clock and has its own time.
|
||
"
|
||
::= { ntp 1 }
|
||
|
||
ntpSysPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the system peer IP address.
|
||
"
|
||
::= { ntp 2 }
|
||
|
||
ntpSysPeerOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the system peer offset.
|
||
"
|
||
::= { ntp 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP PEER STATUS TABLE
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
peerStaTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PeerStaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the peer statistics table."
|
||
::= { ntp 4 }
|
||
|
||
peerStaEntry OBJECT-TYPE
|
||
SYNTAX PeerStaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A peer statistics attributes:
|
||
peerStaIndex
|
||
Reports index for each peer statistics table.
|
||
peerStaAddress
|
||
Reports the peer IP address.
|
||
peerStaHomeMode
|
||
Reports the peer NTP mode.
|
||
peerStaParentMode
|
||
Reports the parent NTP mode.
|
||
peerStaLeap
|
||
Reports leap indicator state.
|
||
peerStaStratum
|
||
Reports peer stratum level.
|
||
peerStaPrecision
|
||
Reports peer precision.
|
||
peerStaDelay
|
||
Reports peer delay.
|
||
peerStaDispersion
|
||
Reports peer dispersion.
|
||
peerStaOffset
|
||
Reports peer offset.
|
||
peerStaSentCnt
|
||
Reports peer sent counter.
|
||
peerStaProcessCnt
|
||
Reports peer process counter.
|
||
peerStaSanity
|
||
Reports status of peer sanity.
|
||
"
|
||
INDEX { peerStaIndex }
|
||
::= { peerStaTable 1 }
|
||
|
||
|
||
PeerStaEntry ::=
|
||
SEQUENCE {
|
||
peerStaIndex
|
||
INTEGER,
|
||
peerStaAddress
|
||
IpAddress,
|
||
peerStaHomeMode
|
||
INTEGER,
|
||
peerStaParentMode
|
||
INTEGER,
|
||
peerStaLeap
|
||
INTEGER,
|
||
peerStaStratum
|
||
INTEGER,
|
||
peerStaPrecision
|
||
INTEGER,
|
||
peerStaDelay
|
||
DisplayString,
|
||
peerStaDispersion
|
||
DisplayString,
|
||
peerStaOffset
|
||
DisplayString,
|
||
peerStaSentCnt
|
||
Counter32,
|
||
peerStaProcessCnt
|
||
Counter32,
|
||
peerStaSanity
|
||
YesValue
|
||
}
|
||
|
||
peerStaIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports index for each peer statistics table.
|
||
This value ranges from 1 to 8."
|
||
::= { peerStaEntry 1 }
|
||
|
||
peerStaAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer IP address.
|
||
"
|
||
::= { peerStaEntry 2 }
|
||
|
||
peerStaHomeMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer NTP mode.
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
"
|
||
::= { peerStaEntry 3 }
|
||
|
||
peerStaParentMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer parent NTP mode.
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
"
|
||
::= { peerStaEntry 4 }
|
||
|
||
peerStaLeap OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
nowarning(0),
|
||
addsec(1),
|
||
delsec(2),
|
||
notinsync(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports leap indicator state.
|
||
Valid values are:
|
||
0 = sync'd, no warning
|
||
1 = 1 second will be added
|
||
2 = 1 second will be subtracted
|
||
3 = not sync'd
|
||
"
|
||
::= { peerStaEntry 5 }
|
||
|
||
|
||
peerStaStratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer stratum level.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { peerStaEntry 6 }
|
||
|
||
peerStaPrecision OBJECT-TYPE
|
||
SYNTAX INTEGER (-1000..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer precision.
|
||
"
|
||
::= { peerStaEntry 7 }
|
||
|
||
peerStaDelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer delay.
|
||
"
|
||
::= { peerStaEntry 8 }
|
||
|
||
peerStaDispersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer dispersion.
|
||
"
|
||
::= { peerStaEntry 9 }
|
||
|
||
peerStaOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer offset.
|
||
"
|
||
::= { peerStaEntry 10 }
|
||
|
||
peerStaSentCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer sent counter.
|
||
"
|
||
::= { peerStaEntry 11 }
|
||
|
||
peerStaProcessCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer process counter.
|
||
"
|
||
::= { peerStaEntry 12 }
|
||
|
||
peerStaSanity OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports status of peer sanity:
|
||
1 = passed
|
||
2 = rejected
|
||
"
|
||
::= { peerStaEntry 13 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP IP TABLE
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ntpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table provides the NTP peer statistics.
|
||
"
|
||
::= { ntp 5 }
|
||
|
||
|
||
ntpEntry OBJECT-TYPE
|
||
SYNTAX NtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"NTP peer attributes.
|
||
ntpIndex
|
||
Index for each NTP peer entry.
|
||
ntpPeer
|
||
Reports NTP peer IP address.
|
||
ntpPeerType
|
||
Report NTP peer mode.
|
||
ntpBrdTimer
|
||
Report NTP broadcast timer
|
||
"
|
||
INDEX { ntpIndex }
|
||
::= { ntpTable 1 }
|
||
|
||
|
||
NtpEntry ::=
|
||
SEQUENCE {
|
||
ntpIndex
|
||
INTEGER,
|
||
ntpPeer
|
||
IpAddress,
|
||
ntpPeerType
|
||
INTEGER,
|
||
ntpBrdTimer
|
||
INTEGER
|
||
}
|
||
|
||
ntpIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each NTP peer entry.
|
||
This value ranges from 1 to 3."
|
||
::= { ntpEntry 1 }
|
||
|
||
|
||
ntpPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP peer IP address.
|
||
If the ip address is zero for this entry, the whole entry has no meaning.
|
||
"
|
||
::= { ntpEntry 2 }
|
||
|
||
ntpPeerType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
client (1),
|
||
broadcast (2),
|
||
bclient (3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP peer mode.
|
||
|
||
CLIENT - The IP for NTP server in client mode.
|
||
BROADCAST - The subnet mask for broadcasting mode.
|
||
BCLIENT - The IP for NTP server in broadcast client mode.
|
||
"
|
||
::= { ntpEntry 3 }
|
||
|
||
|
||
ntpBrdTimer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notuse(0),
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP broadcast timer in
|
||
notuse(0),
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
"
|
||
::= { ntpEntry 4 }
|
||
|
||
|
||
-- ******************************************
|
||
-- NTP SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpAddClient OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP peers to enable client mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 6 }
|
||
|
||
ntpAddBrd OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP servers to enable broadcast mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 7 }
|
||
|
||
ntpAddBclient OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP peers to enable broadcast client mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 8 }
|
||
|
||
|
||
|
||
ntpDelPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Delete NTP servers from the peer table.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 9 }
|
||
|
||
|
||
ntpClr OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr (1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear all the NTP peer addresses in the unit.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 10 }
|
||
|
||
|
||
ntpBTimer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports/Set the broadcast timer
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
"
|
||
::= { ntp 11 }
|
||
|
||
ntpPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gps (1),
|
||
client (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the SSU time-of-day source from GPS or NTP Client.
|
||
"
|
||
::= { ntp 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TIME
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- TOP LEVEL
|
||
tmCurTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current system time.
|
||
|
||
Note: user can change the system time only when the system is in LOCAL mode.
|
||
If the system is SERVER or NTP CLIENT, changing system time is not allowed.
|
||
"
|
||
::= { time 1 }
|
||
|
||
tmLocalOffset OBJECT-TYPE
|
||
SYNTAX TLocalTimeOffset
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set local time offset.
|
||
|
||
Note: This allow the users to set a local time offset.
|
||
The local time offset limits are (+/-)13 hours.
|
||
This is primarily used in systems with GPS or NTP time-of-day references.
|
||
where users' prefer system time to be set to local time.
|
||
"
|
||
::= { time 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 PQL TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- The DS1 PQL Table
|
||
-- ******************************************
|
||
|
||
pqlDs1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PqlDs1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PQL entries.
|
||
The total entries are 16."
|
||
::= { pqlTable 1 }
|
||
|
||
pqlDs1Entry OBJECT-TYPE
|
||
SYNTAX PqlDs1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PQL entry containing objects of each PQL."
|
||
INDEX { pqlDs1Index }
|
||
::= { pqlDs1Table 1 }
|
||
|
||
PqlDs1Entry ::=
|
||
SEQUENCE {
|
||
pqlDs1Index
|
||
INTEGER,
|
||
pqlDs1Ssm
|
||
TSsm,
|
||
pqlDs1Descr
|
||
DisplayString
|
||
}
|
||
|
||
pqlDs1Index OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each PQL table.
|
||
This value ranges from 1 to 16."
|
||
::= { pqlDs1Entry 1 }
|
||
|
||
|
||
pqlDs1Ssm OBJECT-TYPE
|
||
SYNTAX TSsm
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This DS1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
|
||
Note: If value of this entry is 0xff, the entry is not used.
|
||
This is the 8-bit value. If the 8th bit is set, this SSM value is not telcom standard.
|
||
Use caution when modifying as system characteristics will be altered.
|
||
"
|
||
::= { pqlDs1Entry 2 }
|
||
|
||
|
||
pqlDs1Descr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report description for the DS1 Priority Quality Level (PQL) entry."
|
||
::= { pqlDs1Entry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- The E1 PQL Table
|
||
-- ******************************************
|
||
|
||
pqlE1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PqlE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PQL entries.
|
||
The total entries are 16."
|
||
::= { pqlTable 2 }
|
||
|
||
pqlE1Entry OBJECT-TYPE
|
||
SYNTAX PqlE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PQL entry attributes.
|
||
pqlE1Index
|
||
Index value for each PQL table.
|
||
pqlE1Ssm
|
||
Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
pqlE1Descr
|
||
Report/Set description for the E1 Priority Quality Level (PQL) entry.
|
||
"
|
||
INDEX { pqlE1Index }
|
||
::= { pqlE1Table 1 }
|
||
|
||
PqlE1Entry ::=
|
||
SEQUENCE {
|
||
pqlE1Index
|
||
INTEGER,
|
||
pqlE1Ssm
|
||
TSsm,
|
||
pqlE1Descr
|
||
DisplayString
|
||
}
|
||
|
||
pqlE1Index OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for each PQL table.
|
||
This value ranges from 1 to 16."
|
||
::= { pqlE1Entry 1 }
|
||
|
||
|
||
pqlE1Ssm OBJECT-TYPE
|
||
SYNTAX TSsm
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
|
||
Note: If value of this entry is 0xff, this entry is not used.
|
||
This is the 8-bits value. If the 8th bit is set, this SSM value is not telcom standard.
|
||
Use caution when modifying as system characteristics will be altered.
|
||
"
|
||
::= { pqlE1Entry 2 }
|
||
|
||
pqlE1Descr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set description for the E1 Priority Quality Level (PQL) entry."
|
||
::= { pqlE1Entry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- Reset PQL Table
|
||
-- ******************************************
|
||
|
||
pqlReset OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
factory(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1/E1 Priority Quality Level(PQL) tables into factory defaults.
|
||
|
||
Note: It only has meaning for 'write' operations.
|
||
"
|
||
::= { pqlTable 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 IONAME TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ionameTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF IonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of input/output name entries.
|
||
"
|
||
::= { ioname 1 }
|
||
|
||
|
||
ionEntry OBJECT-TYPE
|
||
SYNTAX IonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An io name entry attributes.
|
||
ionChassis
|
||
Identifies which chassis is being addressed.
|
||
ionSlot
|
||
Identifies which slot is being addressed.
|
||
ionPort
|
||
Identifies which port is being addressed.
|
||
ionName
|
||
Report/Set port ioname field.
|
||
"
|
||
INDEX { ionChassis, ionSlot, ionPort }
|
||
::= { ionameTable 1 }
|
||
|
||
IonEntry ::=
|
||
SEQUENCE {
|
||
ionChassis
|
||
INTEGER,
|
||
ionSlot
|
||
INTEGER,
|
||
ionPort
|
||
INTEGER,
|
||
ionName
|
||
DisplayString
|
||
}
|
||
|
||
ionChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 1 }
|
||
|
||
ionSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 2 }
|
||
|
||
|
||
ionPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 3 }
|
||
|
||
ionName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set port ioname field.
|
||
If the name is a null string (zero length), this i/o name s cleared from the port.
|
||
"
|
||
::= { ionEntry 4 }
|
||
|
||
|
||
-- ******************************************
|
||
-- IONAME SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ionameLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The text string of the input/output port.
|
||
The format is defined as xAy-z or xAy-z&&z (if specified the range of ports)
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3, if input) or
|
||
(1 to 20, if output port).
|
||
&& is the two constant letters '&&', and is port range sepearator
|
||
z is the ending port number (1 to 3, if input) or
|
||
(1 to 20, if output port).
|
||
|
||
For example:
|
||
1A3-1 means this port located at chassis 1, slot 3, and port 1.
|
||
2A5-2&&5 means this ports located at chassis 2, slot 5, and ports 2 thru 5.
|
||
|
||
Note: the user must specify valid port address.
|
||
The valid port must be physically installed in the system.
|
||
"
|
||
::= { ioname 2 }
|
||
|
||
|
||
ionameSet OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set name associated input/output ports.
|
||
|
||
If the name is a null string, this i/o name is cleared from the ports.
|
||
|
||
Note: You must specify the i/o port range first, and then provide the i/o name.
|
||
"
|
||
::= { ioname 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION PORT (SUCH AS RS232) GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 RS232
|
||
-- **************************************************************
|
||
|
||
com232Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF ComEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of RS232 port entries. The total entries are 3."
|
||
::= { comm 1 }
|
||
|
||
|
||
comEntry OBJECT-TYPE
|
||
SYNTAX ComEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An RS232 communication entry attributes.
|
||
comIndex
|
||
Index for each communication table.
|
||
comMode
|
||
Set the specified RS232 port command parser to ICS or TL1.
|
||
comEcho
|
||
Enable/disable echo on the specified RS232 port.
|
||
comEol
|
||
Set the specified RS232 port End Of Line (EOL) terminator.
|
||
comBaud
|
||
Set the specified RS232 port baud rate.
|
||
"
|
||
INDEX { comIndex }
|
||
::= { com232Table 1 }
|
||
|
||
ComEntry ::=
|
||
SEQUENCE {
|
||
comIndex
|
||
INTEGER,
|
||
comMode
|
||
INTEGER,
|
||
comEcho
|
||
OnValue,
|
||
comEol
|
||
INTEGER,
|
||
comBaud
|
||
INTEGER
|
||
}
|
||
|
||
|
||
comIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each communication table.
|
||
This value ranges from 1 to 3."
|
||
::= { comEntry 1 }
|
||
|
||
|
||
comMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ics(1),
|
||
tl1(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port command parser to ICS or TL1.
|
||
"
|
||
::= { comEntry 2 }
|
||
|
||
comEcho OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable echo on the specified RS232 port.
|
||
|
||
Note: This only affects the ICS command mode.
|
||
"
|
||
::= { comEntry 3 }
|
||
|
||
comEol OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
cr (1),
|
||
lf (2),
|
||
crlf (3)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port End Of Line (EOL) terminator.
|
||
cr (1),
|
||
lf (2),
|
||
crlf (3)
|
||
"
|
||
::= { comEntry 4 }
|
||
|
||
comBaud OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
baud1200 (1200),
|
||
baud2400 (2400),
|
||
baud4800 (4800),
|
||
baud9600 (9600),
|
||
baud19200 (19200)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port baud rate.
|
||
Valid baud rates are:
|
||
baud1200 (1200),
|
||
baud2400 (2400),
|
||
baud4800 (4800),
|
||
baud9600 (9600),
|
||
baud19200 (19200)
|
||
"
|
||
::= { comEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION (INCLUDE TELNET AND ETHERNET TL1)
|
||
-- **************************************************************
|
||
|
||
comParmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF ComParmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of communication port setting entries (such as timeout).
|
||
The total entries are 5."
|
||
::= { comm 2 }
|
||
|
||
|
||
comParmEntry OBJECT-TYPE
|
||
SYNTAX ComParmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Communication setting entry for each logical port.
|
||
comParmIndex
|
||
Index for each communication parameter table.
|
||
comType
|
||
Specify the communication port.
|
||
comTimeout
|
||
Report/Set communication port session timeout (in seconds).
|
||
"
|
||
INDEX { comParmIndex }
|
||
::= { comParmTable 1 }
|
||
|
||
|
||
ComParmEntry ::=
|
||
SEQUENCE {
|
||
comParmIndex
|
||
INTEGER,
|
||
comType
|
||
INTEGER,
|
||
comTimeout
|
||
INTEGER
|
||
}
|
||
|
||
|
||
comParmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each communication parameter table.
|
||
This value ranges from 1 to 5."
|
||
::= { comParmEntry 1 }
|
||
|
||
|
||
comType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telnet (4),
|
||
etl1 (5) -- Ethernet TL1
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specify the communication port.
|
||
Valid values are:
|
||
1 = local (RS232)
|
||
2 = com A (RS232)
|
||
3 = com B (RS232)
|
||
4 = telnet
|
||
5 = telnet TL1 port
|
||
"
|
||
::= { comParmEntry 2 }
|
||
|
||
comTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (0| 5..43200)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set communication port session timeout (in seconds).
|
||
|
||
Note: 0 = NEVER timeout.
|
||
"
|
||
::= { comParmEntry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- COM SCALER METHODS
|
||
-- ******************************************
|
||
|
||
comLogoff OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telneta (4),
|
||
telnetb (5),
|
||
telnetc (6),
|
||
telnetd (7),
|
||
etl1a (8),
|
||
etl1b (9),
|
||
etl1c (10),
|
||
etl1d (11)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Logoff user on another logical communication port.
|
||
|
||
The valid communication port are:
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telneta (4),
|
||
telnetb (5),
|
||
telnetc (6),
|
||
telnetd (7),
|
||
etl1a (8),
|
||
etl1b (9),
|
||
etl1c (10),
|
||
etl1d (11)
|
||
|
||
Note: This field only has meaning for 'write' operations.
|
||
"
|
||
::= { comm 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv2 MANAGER TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
snmpv2manTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv2manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the SNMPv2 manager(s) IP address.
|
||
"
|
||
::= { snmpman 1 }
|
||
|
||
snmpv2manEntry OBJECT-TYPE
|
||
SYNTAX Snmpv2manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 manager table attributes.
|
||
snmpv2manIndex
|
||
Index for each SNMPv2 manager table entry.
|
||
snmpv2manIp
|
||
Set the snmpv2 manager IP address.
|
||
"
|
||
INDEX { snmpv2manIndex }
|
||
::= { snmpv2manTable 1 }
|
||
|
||
Snmpv2manEntry ::=
|
||
SEQUENCE {
|
||
snmpv2manIndex
|
||
INTEGER,
|
||
snmpv2manIp
|
||
IpAddress
|
||
}
|
||
|
||
snmpv2manIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv2 manager table entry.
|
||
This value range from 1 to 4."
|
||
::= { snmpv2manEntry 1 }
|
||
|
||
snmpv2manIp OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the snmpv2 manager IP address.
|
||
Write a new IP address will put this new IP into table.
|
||
Write zero IP address will delete this IP address from table.
|
||
Note: The above only apply to SNMPv2.
|
||
"
|
||
::= { snmpv2manEntry 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- SNMP SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
snmpmanInit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
initv2 (1), -- initialize the SNMPv2 manager table
|
||
initv3 (2) -- initialize the SNMPv3 manager table
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Initializes the SNMP Manager Table to null IP addresses.
|
||
Note: This field only has meaning when 'write' operations
|
||
"
|
||
::= { snmpman 2 }
|
||
|
||
|
||
snmpmanTrap OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
alarm(1),
|
||
all(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the SNMP trap filter to SNMP Manager.
|
||
The trap filter can be set to be 'alarm' only or all traps.
|
||
|
||
1 = alarm
|
||
2 = all
|
||
|
||
If 'alarm' trap, only events with ID less than 32 (i.e. alarms)
|
||
will be sent to the SNMP Manager. All other traps will be filtered
|
||
out. The purpose of this command is to reduce the traffic, if
|
||
desired.
|
||
"
|
||
::= { snmpman 3 }
|
||
|
||
|
||
snmpNotification OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
v2 (1), -- traps in v2 form, address from v2 manager table
|
||
v3 (2), -- traps in v3 form, address from v2 manager table
|
||
all(3) -- traps in v2/v3, address from v2/v3 table accordingly
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set SNMPv3 traps format to use.
|
||
v2 (1), -- traps in v2 form, address from v2 manager table
|
||
v3 (2), -- traps in v3 form, address from v2 manager table
|
||
all(3) -- traps in v2/v3, address from v2/v3 table accordingly
|
||
It can V2, V3, or both forms. Each v2/v3 traps sent out are viaits own manager table accordingly.
|
||
Note: The above only apply to SNMPv3 load.
|
||
"
|
||
::= { snmpman 4 }
|
||
|
||
snmpEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
v2enable(1), -- activate SNMPv2
|
||
v2disable(2) -- deactivate SNMPv2
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Activate/deactivate SNMPv2.
|
||
Note: The above only apply to SNMPv3 load.
|
||
"
|
||
::= { snmpman 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv2 User TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv2userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv2userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 User Table.
|
||
"
|
||
::= { snmpman 6 }
|
||
|
||
snmpv2userEntry OBJECT-TYPE
|
||
SYNTAX Snmpv2userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 user table entry attributes.
|
||
snmpv2userIndex
|
||
Index for each SNMPv2 user table entry.
|
||
snmpv2user
|
||
Reports SNMPv2 user
|
||
"
|
||
INDEX { snmpv2userIndex }
|
||
::= { snmpv2userTable 1 }
|
||
|
||
Snmpv2userEntry ::=
|
||
SEQUENCE {
|
||
snmpv2userIndex
|
||
INTEGER,
|
||
snmpv2user
|
||
DisplayString
|
||
}
|
||
|
||
snmpv2userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv2 user entry.
|
||
"
|
||
::= { snmpv2userEntry 1 }
|
||
|
||
snmpv2user OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv2 user entry
|
||
It is the read community string of an SNMPv2 user
|
||
"
|
||
::= { snmpv2userEntry 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv3 User TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv3userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv3userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 User Table.
|
||
"
|
||
::= { snmpman 7 }
|
||
|
||
snmpv3userEntry OBJECT-TYPE
|
||
SYNTAX Snmpv3userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 user table entry attributes.
|
||
snmpv3userIndex
|
||
Index for each SNMPv3 user table entry.
|
||
snmpv3user
|
||
Reports SNMPv3 user
|
||
"
|
||
INDEX { snmpv3userIndex }
|
||
::= { snmpv3userTable 1 }
|
||
|
||
Snmpv3userEntry ::=
|
||
SEQUENCE {
|
||
snmpv3userIndex
|
||
INTEGER,
|
||
snmpv3user
|
||
DisplayString
|
||
}
|
||
|
||
snmpv3userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv3 user table entry.
|
||
"
|
||
::= { snmpv3userEntry 1 }
|
||
|
||
snmpv3user OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv3 user
|
||
"
|
||
::= { snmpv3userEntry 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv3 MANAGER TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv3manTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv3manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv3 manager IP address.
|
||
"
|
||
::= { snmpman 8 }
|
||
|
||
snmpv3manEntry OBJECT-TYPE
|
||
SYNTAX Snmpv3manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 manager entry attributes.
|
||
snmpv3manIndex
|
||
Index for each SNMPv3 manager entry.
|
||
snmpv3manIp
|
||
Report/Set snmpv3 manager IP address.
|
||
snmpv3manUser
|
||
Report/Set the SNMPv3 user
|
||
"
|
||
INDEX { snmpv3manIndex }
|
||
::= { snmpv3manTable 1 }
|
||
|
||
Snmpv3manEntry ::=
|
||
SEQUENCE {
|
||
snmpv3manIndex
|
||
INTEGER,
|
||
snmpv3manIp
|
||
IpAddress,
|
||
snmpv3manUser
|
||
DisplayString
|
||
}
|
||
|
||
snmpv3manIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv3 manager entry.
|
||
This value range from 1 to 4."
|
||
::= { snmpv3manEntry 1 }
|
||
|
||
snmpv3manIp OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set snmpv3 manager IP address.
|
||
|
||
Note: No action shall be taken at this time.
|
||
Action shall be taken when the next field 'snmpv3manUser'is written.
|
||
The above only apply to SNMPv3.
|
||
"
|
||
::= { snmpv3manEntry 2 }
|
||
|
||
snmpv3manUser OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the SNMPv3 user
|
||
|
||
Note1: All user names are uppercase except the built-in user.
|
||
Write username will put this user along with ip into table.
|
||
Writing a null string will delete this entry from table.
|
||
Any previouly written IP has no meaning (i.e. the writing the null
|
||
string of username shall trigger the delete action of that entry from table.
|
||
Note2: There is no modify action. User need to delete an entry and then add an new entry.
|
||
Note3: The above only apply to SNMPv3.
|
||
"
|
||
::= { snmpv3manEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SYSTEM TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
sysPbo OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
event(1),
|
||
report(2),
|
||
none(3),
|
||
disable(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The input port Phase Built-Out ode (PBO).
|
||
1 = EVENT : PBO enabled, PBO sent out, and stored
|
||
in the event buffer.
|
||
2 = REPORT : PBO enabled, PBO sent out, but not stored
|
||
in the event buffer.
|
||
3 = NONE : PBO enabled, but PBO event not sent out.
|
||
4 = DISABLE : PBO disabled.
|
||
|
||
Note: This is a system-wide command.
|
||
When the user writes this field, it will affect all DS1/E1 input modules in the system.
|
||
"
|
||
::= { sys 1 }
|
||
|
||
sysResetClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reset the specified clock.
|
||
Restarts clock without maintaining current servo control values.
|
||
"
|
||
::= { sys 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 KEEPALIVE TABLE
|
||
-- **************************************************************
|
||
|
||
sysKeepAliveTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SysAliveEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set system 'keep alive' mode
|
||
where a trap is generated automatically on a period specified by the customer
|
||
This is intended to verify the upstream support that the SSU2000 and the associated communication path is functional"
|
||
::= { sys 3 }
|
||
|
||
|
||
sysAliveEntry OBJECT-TYPE
|
||
SYNTAX SysAliveEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"System 'keepalive' attributes for TL1 or SNMP.
|
||
sysAliveIndex
|
||
Index value for each 'keepalive' table.
|
||
sysAliveType
|
||
Keep Alive session type:
|
||
sysAliveTime
|
||
Keep alive message interval.
|
||
"
|
||
INDEX { sysAliveIndex }
|
||
::= { sysKeepAliveTable 1 }
|
||
|
||
|
||
SysAliveEntry ::=
|
||
SEQUENCE {
|
||
sysAliveIndex
|
||
INTEGER,
|
||
sysAliveType
|
||
INTEGER,
|
||
sysAliveTime
|
||
INTEGER
|
||
}
|
||
|
||
sysAliveIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for each 'keepalive' table.
|
||
This range of the value is from 1 to 2."
|
||
::= { sysAliveEntry 1 }
|
||
|
||
|
||
sysAliveType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
tl1(1),
|
||
snmp(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Keep Alive session type:
|
||
1 = TL1 session
|
||
2 = SNMP session
|
||
"
|
||
::= { sysAliveEntry 2 }
|
||
|
||
|
||
sysAliveTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Keep alive message interval.
|
||
Valid range = 1 - 60 (minutes).
|
||
0 = disabled (default)
|
||
"
|
||
::= { sysAliveEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- Unit Operating Mode
|
||
-- **************************************************************
|
||
|
||
sysOpmode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
normal(1), -- Non-Subtending
|
||
subtending(2), -- Domestic Subtending
|
||
japanese(3) -- Japanese Subtending
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the operational mode in the SSU-2000.
|
||
normal(1), -- Non-Subtending
|
||
subtending(2), -- Domestic Subtending
|
||
japanese(3) -- Japanese Subtending
|
||
"
|
||
::= { sys 4 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- TL1 format
|
||
-- **************************************************************
|
||
|
||
sysTl1Format OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gr831(1),
|
||
gr833(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TL1 format in the SSU-2000.
|
||
Allows the system to generate GR-831 compliant or GR-833 compliant autonomous events.
|
||
All SSU-2000 TL1 sessions will generate either GR-831 or GR-833 autonomous events.
|
||
Refer to TL1 Specification 12613127-001-2 for event formats
|
||
"
|
||
::= { sys 5 }
|
||
|
||
-- **************************************************************
|
||
-- LOGIN/ LOGOUT EVENT
|
||
-- **************************************************************
|
||
|
||
sysEvtLogin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(1), -- not store login and logout in the event log
|
||
enable(2) -- store login and logout in the event log
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set LOGIN and LOGOUT events from being stored in the event log.
|
||
|
||
disable(1), -- not store login and logout in the event log
|
||
enable(2) -- store login and logout in the event log
|
||
"
|
||
::= { sys 6 }
|
||
|
||
-- **************************************************************
|
||
-- Alarm Cut Off (ACO)
|
||
-- **************************************************************
|
||
|
||
sysAco OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1), -- ACO active
|
||
inactive(2) -- ACO inactive
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set ACO when writing with active.
|
||
It has NOP when write with inactive.
|
||
When read, it returns the current state of ACO.
|
||
"
|
||
::= { sys 7 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 USERS TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF UserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report valid user names and their associated user access level.
|
||
This user list is used for connecting the ICS and TL1 command parser via RS232 or Ethernet port (telnet or TL1 port).
|
||
Note: the password is not reported.
|
||
"
|
||
::= { users 1 }
|
||
|
||
userEntry OBJECT-TYPE
|
||
SYNTAX UserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User table attributes:
|
||
userIndex
|
||
Index for each user entry.
|
||
userlevel
|
||
Reports user access level.
|
||
username
|
||
Reports user name.
|
||
"
|
||
INDEX { userIndex }
|
||
::= { userTable 1 }
|
||
|
||
|
||
UserEntry ::=
|
||
SEQUENCE {
|
||
userIndex
|
||
INTEGER,
|
||
userlevel
|
||
INTEGER,
|
||
username
|
||
DisplayString
|
||
}
|
||
|
||
userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..25)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports index for each user entry.
|
||
This value ranges from 1 to 25.
|
||
"
|
||
::= { userEntry 1 }
|
||
|
||
|
||
userlevel OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports user access level.
|
||
The user level:
|
||
(1) USER - Read Only - can retrieve status information only.
|
||
(2) TECHNICIAN - Read and limited set ability for fault isolating and installation setup of the unit.
|
||
(3) SUPERVISORY - For configuration modifications.
|
||
(4) ADMINISTRATOR - Setup or change user access.
|
||
"
|
||
::= { userEntry 2 }
|
||
|
||
|
||
username OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports user name."
|
||
::= { userEntry 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 WHO TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
whoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WhoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which users are logged into all active communication ports (RS232, TL1, or telnet).
|
||
It displays the username and the communication port.
|
||
"
|
||
::= { who 1 }
|
||
|
||
whoEntry OBJECT-TYPE
|
||
SYNTAX WhoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report 'who' table attributes.
|
||
whoIndex
|
||
Report index of the 'who' entry.
|
||
whoPort
|
||
Report logical communication port.
|
||
whoName
|
||
Report user name.
|
||
"
|
||
INDEX { whoIndex }
|
||
::= { whoTable 1 }
|
||
|
||
WhoEntry ::=
|
||
SEQUENCE {
|
||
whoIndex
|
||
INTEGER,
|
||
whoPort
|
||
INTEGER,
|
||
whoName
|
||
DisplayString
|
||
}
|
||
|
||
whoIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..12)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report index of the 'who' entry.
|
||
This value ranges from 1 to 11."
|
||
::= { whoEntry 1 }
|
||
|
||
whoPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local(1),
|
||
coma(2),
|
||
comb(3),
|
||
telneta(4),
|
||
telnetb(5),
|
||
telnetc(6),
|
||
telnetd(7),
|
||
etl1a(8),
|
||
etl1b(9),
|
||
etl1c(10),
|
||
etl1d(11)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report logical communication port.
|
||
local(1), -- serial local (craft) port
|
||
coma(2), -- serial port A
|
||
comb(3), -- serial port B
|
||
telneta(4), -- telnet session A
|
||
telnetb(5), -- telnet session B
|
||
telnetc(6), -- telnet session C
|
||
telnetd(7), -- telnet session D
|
||
etl1a(8), -- TL1 session A
|
||
etl1b(9), -- TL1 session B
|
||
etl1c(10), -- TL1 session C
|
||
etl1d(11) -- TL1 session D
|
||
"
|
||
::= { whoEntry 2 }
|
||
|
||
|
||
whoName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report user name."
|
||
::= { whoEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTPQ GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpqXeq OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the PackeTime Module.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A6 means this PackeTime located at chassis 1, slot 6
|
||
|
||
Note: the user must specify valid PackeTime address.
|
||
The valid module must be physically installed in the system.
|
||
Note: Writing operation causes the system to execute the ntpq.
|
||
The ntpq returned value may take 2 seconds.
|
||
"
|
||
::= { ntpq 1 }
|
||
|
||
ntpqSyspeer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report syspeer is the IP address of peer selected by server as most likely to provide best timing information.
|
||
"
|
||
::= { ntpq 4 }
|
||
|
||
ntpqSysleap OBJECT-TYPE
|
||
SYNTAX INTEGER (-1..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report system leap indicator
|
||
The NTP server leap indicator (0, +1, -1, or NOSYNC).
|
||
2 = NOSYNC
|
||
"
|
||
::= { ntpq 5 }
|
||
|
||
ntpqSysstratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report system NTP server stratum level
|
||
"
|
||
::= { ntpq 6 }
|
||
|
||
ntpqSysprecision OBJECT-TYPE
|
||
SYNTAX INTEGER (-100..0)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report measurement of a number of significant bits in NTP timestamp
|
||
"
|
||
::= { ntpq 7 }
|
||
|
||
ntpqRootdelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report calculated root delay value to primary source
|
||
"
|
||
::= { ntpq 8 }
|
||
|
||
ntpqRootdispersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP system Root Dispersion (max error relative to the primary
|
||
reference source at the root of the synchronization subnet, in seconds)
|
||
"
|
||
::= { ntpq 9 }
|
||
|
||
ntpqSysoffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report clients calculated time offset value for the specified server
|
||
"
|
||
::= { ntpq 10 }
|
||
|
||
ntpqReftime OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..60))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report local reference time
|
||
"
|
||
::= { ntpq 11 }
|
||
|
||
-- ******************************************
|
||
-- NTPQ TABLE
|
||
-- ******************************************
|
||
|
||
ntpqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NtpqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTPQ entries.
|
||
"
|
||
::= { ntpq 3 }
|
||
|
||
ntpqEntry OBJECT-TYPE
|
||
SYNTAX NtpqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTPQ attributes.
|
||
ntpqChassis
|
||
Identifies which chassis is being addressed.
|
||
ntpqSlot
|
||
Identifies which slot is being addressed.
|
||
ntpqIndex
|
||
Identifies which index is being addressed.
|
||
ntpqValid
|
||
Reports validity of entry.
|
||
ntpqPeer
|
||
Reports address of NTP peer
|
||
ntpqRefid
|
||
Reports NTP peer reference ID
|
||
ntpqStratum
|
||
Reports NTP peer stratum level
|
||
ntpqPoll
|
||
Reports NTP peer poll interval
|
||
ntpqReach
|
||
Reports NTP peer reachability
|
||
ntpqDelay
|
||
Reports NTP peer delay
|
||
ntpqOffset
|
||
Reports NTP peer offset
|
||
ntpqJitter
|
||
Report NTP peer jitter
|
||
"
|
||
INDEX { ntpqChassis, ntpqSlot, ntpqIndex }
|
||
::= { ntpqTable 1 }
|
||
|
||
NtpqEntry ::=
|
||
SEQUENCE {
|
||
ntpqChassis
|
||
INTEGER,
|
||
ntpqSlot
|
||
INTEGER,
|
||
ntpqIndex
|
||
INTEGER,
|
||
ntpqValid
|
||
ValidValue,
|
||
ntpqPeer
|
||
DisplayString,
|
||
ntpqRefid
|
||
DisplayString,
|
||
ntpqStratum
|
||
INTEGER,
|
||
ntpqPoll
|
||
INTEGER,
|
||
ntpqReach
|
||
DisplayString,
|
||
ntpqDelay
|
||
DisplayString,
|
||
ntpqOffset
|
||
DisplayString,
|
||
ntpqJitter
|
||
DisplayString
|
||
}
|
||
|
||
ntpqChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 1 }
|
||
|
||
ntpqSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 2 }
|
||
|
||
ntpqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which index is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 3 }
|
||
|
||
ntpqValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports validity of entry.
|
||
If this entry is not valid, all info in this entry has no meaning.
|
||
"
|
||
::= { ntpqEntry 4 }
|
||
|
||
ntpqPeer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports address of NTP peer
|
||
"
|
||
::= { ntpqEntry 5 }
|
||
|
||
ntpqRefid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP system Reference
|
||
"
|
||
::= { ntpqEntry 6 }
|
||
|
||
ntpqStratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server stratum level
|
||
"
|
||
::= { ntpqEntry 7 }
|
||
|
||
ntpqPoll OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1024)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server poll interval
|
||
"
|
||
::= { ntpqEntry 8 }
|
||
|
||
ntpqReach OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server reachability
|
||
"
|
||
::= { ntpqEntry 9 }
|
||
|
||
ntpqDelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated root delay value to primary source
|
||
"
|
||
::= { ntpqEntry 10 }
|
||
|
||
ntpqOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports client's calculated time offset value for the specified server
|
||
"
|
||
::= { ntpqEntry 11 }
|
||
|
||
ntpqJitter OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report jitter value
|
||
"
|
||
::= { ntpqEntry 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 STATIC ROUTE STATUS GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
rtXeq OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write access level: level 1 or above
|
||
|
||
The text string of the PackeTime Module.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A6 means this PackeTime located at
|
||
chassis 1, slot 6
|
||
|
||
Note1: the user must specify valid PackeTime address.
|
||
The valid module must be physically installed in the system.
|
||
Note2: Writing operation causes the system to execute the route table.
|
||
The route table returned value may take 2 seconds.
|
||
"
|
||
::= { route 1 }
|
||
|
||
-- ******************************************
|
||
-- ROUTE TABLE
|
||
-- ******************************************
|
||
|
||
routeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF RouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime route entries.
|
||
"
|
||
::= { route 3 }
|
||
|
||
rtEntry OBJECT-TYPE
|
||
SYNTAX RouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime route table attributes:
|
||
rtChassis
|
||
Identifies which chassis is being addressed.
|
||
rtSlot
|
||
Identifies which slot is being addressed.
|
||
rtIndex
|
||
Identifies which index is being addressed.
|
||
rtValid
|
||
Reports validity of entry.
|
||
rtDest
|
||
Reports destination network/host
|
||
rtGate
|
||
Reports destination gateway
|
||
rtMask
|
||
Reports destination network mask
|
||
rtFlags
|
||
Reports route flags
|
||
rtMetric
|
||
Reports the 'distance' to the target (router hops).
|
||
rtRef
|
||
Reports number of references to this route.
|
||
rtUse
|
||
Report number of lookups for the route.
|
||
rtIface
|
||
Report interface associated with this route.
|
||
"
|
||
INDEX { rtChassis, rtSlot, rtIndex }
|
||
::= { routeTable 1 }
|
||
|
||
RouteEntry ::=
|
||
SEQUENCE {
|
||
rtChassis
|
||
INTEGER,
|
||
rtSlot
|
||
INTEGER,
|
||
rtIndex
|
||
INTEGER,
|
||
rtValid
|
||
ValidValue,
|
||
rtDest
|
||
IpAddress,
|
||
rtGate
|
||
IpAddress,
|
||
rtMask
|
||
IpAddress,
|
||
rtFlags
|
||
DisplayString,
|
||
rtMetric
|
||
INTEGER,
|
||
rtRef
|
||
INTEGER,
|
||
rtUse
|
||
INTEGER,
|
||
rtIface
|
||
INTEGER
|
||
}
|
||
|
||
rtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 1 }
|
||
|
||
rtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 2 }
|
||
|
||
rtIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which index is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 3 }
|
||
|
||
rtValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports validity of entry.
|
||
If this entry is not valid, all info in this entry has no meaning.
|
||
"
|
||
::= { rtEntry 4 }
|
||
|
||
rtDest OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports destination network/host
|
||
or 0.0.0.0 is default.
|
||
"
|
||
::= { rtEntry 5 }
|
||
|
||
rtGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports gateway address
|
||
or 0.0.0.0 if none set
|
||
"
|
||
::= { rtEntry 6 }
|
||
|
||
rtMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports netmask for the destination net;
|
||
'255.255.255.255' for a host destination and '0.0.0.0' for the default route.
|
||
"
|
||
::= { rtEntry 7 }
|
||
|
||
rtFlags OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Reports route table flags
|
||
U (route is up)
|
||
H (target is a host)
|
||
G (use gateway)
|
||
R (reinstate route for dynamic routing)
|
||
D (dynamically installed by daemon or redirect)
|
||
M (modified from routing daemon or redirect)
|
||
A (installed by addrconf)
|
||
C (cache entry)
|
||
! (reject route)
|
||
"
|
||
::= { rtEntry 8 }
|
||
|
||
rtMetric OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the 'distance' to the target (router hops).
|
||
"
|
||
::= { rtEntry 9 }
|
||
|
||
rtRef OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports number of references to this route.
|
||
"
|
||
::= { rtEntry 10 }
|
||
|
||
rtUse OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report number of lookups for the route.
|
||
"
|
||
::= { rtEntry 11 }
|
||
|
||
rtIface OBJECT-TYPE
|
||
SYNTAX INTEGER (0..34094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report interface associated with this route.
|
||
0 = eth0 (Maintenance Port)
|
||
1 = eth1 (Service Port A)
|
||
2 = eth2 (Service Port B)
|
||
3 = bond0 (Service Port Bonding)
|
||
10000-14094 = eth1.xxxx
|
||
20000-24094 = eth2.xxxx
|
||
30000-34094 = bond0.xxxx
|
||
where xxxx is the VLAN ID.
|
||
"
|
||
::= { rtEntry 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP REQUEST GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
tprTag OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This command is to ask the agent to resend a lost trap.
|
||
The lost trap is specified by its trap tag number.
|
||
The trap tag number is a 32-bit positive integer. It will
|
||
rollover to one, when it reaches the maximum number
|
||
2147483647.
|
||
|
||
If the tag number is beyond the agent's abilities to handle,
|
||
it will respond with an error. Otherwise, the requested trap
|
||
will be sent to the manager.
|
||
|
||
Note: When resending a trap, the 'tpEvt' field of trap is set
|
||
to 2 (RE-SEND). In the normal trap, the'tpEvt' field of trap
|
||
is set to 1 (AUTONOMOUS).
|
||
"
|
||
::= { mTrapReq 1 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP OBJECTS
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
tpTag OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap counter which increments for each trap.
|
||
"
|
||
::= { mTrapObjs 1 }
|
||
|
||
tpEvt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
autonomous(1),
|
||
resend(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indication of whether trap is an autonomous event or resend by user request.
|
||
"
|
||
::= { mTrapObjs 2 }
|
||
|
||
tpId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap ID number."
|
||
::= { mTrapObjs 3 }
|
||
|
||
tpMCode OBJECT-TYPE
|
||
SYNTAX TModuleCode
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap module hex code (16-bits)."
|
||
::= { mTrapObjs 4 }
|
||
|
||
tpTimestamp OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This DateAndTime string contains the event timestamp."
|
||
::= { mTrapObjs 5 }
|
||
|
||
tpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap chassis number.
|
||
In SSU2000, there are some modules have to inserted in the main chassis:
|
||
COMM, CLOCK, INPUT, GPS modules.
|
||
"
|
||
::= { mTrapObjs 6 }
|
||
|
||
tpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap slot number.
|
||
In SSU2000, there are some modules have to inserted in the fixed locations:
|
||
COMM - 1A2
|
||
CLOCK - 1A1 or 1A17 (physical slot address)
|
||
GPS - 1A3 or 1A5.
|
||
"
|
||
::= { mTrapObjs 7 }
|
||
|
||
tpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap port number.
|
||
If value 0, it means (DON'T CARE) whole module.
|
||
In SSU2000, most of the DS1/E1 input module alarms specify the port number (1-3).
|
||
The remaining modules specify the port number as either '0' or '1'.
|
||
"
|
||
::= { mTrapObjs 8 }
|
||
|
||
|
||
tpAlmCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap alarm code.
|
||
|
||
Relationship between tpAlmCode and tpNtfCode.
|
||
For example:
|
||
If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR.
|
||
If the MINIR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR.
|
||
|
||
For all events:
|
||
The tpAlmCode and tpNtfCode are REPORT.
|
||
"
|
||
::= { mTrapObjs 9 }
|
||
|
||
tpNtfCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
report(5),
|
||
clear(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap alarm notification code.
|
||
|
||
Relationship between tpAlmCode and tpNtfCode.
|
||
For example for alarms:
|
||
If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR.
|
||
If the MINOR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR.
|
||
|
||
For all events:
|
||
The tpAlmCode and tpNtfCode are REPORT.
|
||
"
|
||
::= { mTrapObjs 10 }
|
||
|
||
tpElevated OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1),
|
||
no(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This alarm if elevated."
|
||
::= { mTrapObjs 11 }
|
||
|
||
tpDescr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The text string description of the event.
|
||
"
|
||
::= { mTrapObjs 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP NOTIFICATION OBJECTS
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ssuTraps OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SSU2000 traps"
|
||
::= {mTraps 0}
|
||
|
||
|
||
ssuEvent NOTIFICATION-TYPE
|
||
OBJECTS {tpTag, tpEvt, tpId, tpMCode,tpTimestamp,
|
||
tpChassis, tpSlot, tpPort,
|
||
tpAlmCode, tpNtfCode, tpElevated, tpDescr}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SSU2000 trap object which specifies trap tag number, trap id number, module hex code, timestamp, chassis number,
|
||
slot number, port number, alarm code, alarm notification code, and the text string description.
|
||
"
|
||
::= {ssuTraps 1}
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 INTERFACES OBJECTS
|
||
-- Note: Developer could use following objects to determine the
|
||
-- SSU2000 resources in the unit right away.
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
sifNtpNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no NTP resource present
|
||
1 = if NTP presentt
|
||
"
|
||
::= { sInterfaces 1 }
|
||
|
||
sifSnmpv2Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no SNMPv2 resource present (note: it is load resource, not enable/disable)
|
||
1 = if SNMPv2 present
|
||
"
|
||
::= { sInterfaces 2 }
|
||
|
||
sifSnmpv3Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no SNMPv3 resource present (note: it is load resource, not enable/disable)
|
||
1 = if SNMPv3 present
|
||
"
|
||
::= { sInterfaces 3 }
|
||
|
||
sifClkNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Clock Module present
|
||
x = number of Clock Modules present
|
||
"
|
||
::= { sInterfaces 10 }
|
||
|
||
sifGpsNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no GPS Module present
|
||
x = number of GPS Modules present
|
||
"
|
||
::= { sInterfaces 11 }
|
||
|
||
sifInpDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 Input Module present
|
||
x = number of DS1 Input Modules present
|
||
"
|
||
::= { sInterfaces 12 }
|
||
|
||
sifInpE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 Input Module present
|
||
x = number of E1 Input Modules present
|
||
"
|
||
::= { sInterfaces 13 }
|
||
|
||
sifInpCcNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no ANSI CC Input Module present
|
||
x = number of ANSI CC Input Modules present
|
||
"
|
||
::= { sInterfaces 14 }
|
||
|
||
sifOutDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 Output Module present
|
||
x = number of DS1 Output Modules present
|
||
"
|
||
::= { sInterfaces 15 }
|
||
|
||
sifOutE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 Output Module present
|
||
x = number of E1 Output Modules present
|
||
"
|
||
::= { sInterfaces 16 }
|
||
|
||
sifOut2048Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no 2048 Output Module present
|
||
x = number of 2048 Output Modules present
|
||
"
|
||
::= { sInterfaces 17 }
|
||
|
||
sifOutCcNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no ANSI CC Output Module present
|
||
x = number of ANSI CC Output Modules present
|
||
"
|
||
::= { sInterfaces 18 }
|
||
|
||
|
||
sifOutE12048Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1/2048KHZ Output Module present
|
||
x = number of E1/2048KHZ Output Modules present
|
||
"
|
||
::= { sInterfaces 19 }
|
||
|
||
sifOut422Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no RS422 Output Module present
|
||
x = number of RS422 Output Modules present
|
||
"
|
||
::= { sInterfaces 20 }
|
||
|
||
sifLrmDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 LRM Module present
|
||
x = number of DS1 LRM Modules present
|
||
"
|
||
::= { sInterfaces 21 }
|
||
|
||
|
||
sifOutJsineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese Sine (J/SW) Output Module present
|
||
x = number of Sine (J/SW) Output Modules present
|
||
"
|
||
::= { sInterfaces 22 }
|
||
|
||
sifInpJsineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese Sine (J/SW) Input Module present
|
||
x = number of Sine (J/SW) Input Modules present
|
||
"
|
||
::= { sInterfaces 23 }
|
||
|
||
sifOutJccNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese CC (J/CC) Output Module present
|
||
x = number of Japanese CC (J/CC) Output Modules present
|
||
"
|
||
::= { sInterfaces 24 }
|
||
|
||
sifInpJccNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese CC (J/CC) Input Module present
|
||
x = number of Japanese CC (J/CC) Input Modules present
|
||
"
|
||
::= { sInterfaces 25 }
|
||
|
||
sifLrmE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 LRM Module present
|
||
x = number of E1 LRM Modules present
|
||
"
|
||
::= { sInterfaces 26 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME PTP MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staPtPtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime PTP status information.
|
||
"
|
||
::= { statusPtPtp 1 }
|
||
|
||
|
||
staPtPtpEntry OBJECT-TYPE
|
||
SYNTAX StaPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP status attributes.
|
||
"
|
||
INDEX { staPtPtpChassis, staPtPtpSlot}
|
||
::= { staPtPtpTable 1 }
|
||
|
||
StaPtPtpEntry ::=
|
||
SEQUENCE {
|
||
staPtPtpChassis
|
||
INTEGER,
|
||
staPtPtpSlot
|
||
INTEGER,
|
||
staPtPtpStatus
|
||
INTEGER,
|
||
staPtPtpClkSel
|
||
INTEGER,
|
||
staPtPtpClka
|
||
ActiveValue,
|
||
staPtPtpClkb
|
||
ActiveValue,
|
||
staPtPtpClkc
|
||
ActiveValue,
|
||
staPtPtpClkd
|
||
ActiveValue,
|
||
staPtPtpRednt
|
||
INTEGER,
|
||
staPtPtpModState
|
||
INTEGER,
|
||
staPtPtpPAState
|
||
INTEGER,
|
||
staPtPtpTod
|
||
OnValue,
|
||
staPtPtpCommit
|
||
INTEGER
|
||
}
|
||
|
||
staPtPtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtPtpEntry 1 }
|
||
|
||
staPtPtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtPtpEntry 2 }
|
||
|
||
|
||
staPtPtpStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with fault(s)
|
||
reject(5) -- module type between redundant modules do not agree
|
||
"
|
||
::= { staPtPtpEntry 3 }
|
||
|
||
staPtPtpClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock reference is selected to generate the output reference.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staPtPtpEntry 4 }
|
||
|
||
staPtPtpClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staPtPtpEntry 5 }
|
||
|
||
staPtPtpClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staPtPtpEntry 6 }
|
||
|
||
staPtPtpClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staPtPtpEntry 7 }
|
||
|
||
staPtPtpClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staPtPtpEntry 8 }
|
||
|
||
staPtPtpRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staPtPtpEntry 9 }
|
||
|
||
staPtPtpModState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If the module is in redundant pair and selected, it shall return active.
|
||
stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby).
|
||
fault(3), --If the module disabled, it will return fault.
|
||
stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtPtpEntry 10 }
|
||
|
||
staPtPtpPAState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtPtpEntry 11 }
|
||
|
||
staPtPtpTod OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the PTP Time of Day is valid or invalid.
|
||
"
|
||
::= { staPtPtpEntry 12 }
|
||
|
||
staPtPtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
done(1),
|
||
prog(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Commit command status.
|
||
1 = done
|
||
2 = in progress
|
||
"
|
||
::= { staPtPtpEntry 13 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpDfltDataSetTable
|
||
-- **************************************************************
|
||
|
||
ptpDfltDataSetTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpDfltDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpDefaultDataSet
|
||
"
|
||
::= { statusPtPtp 2 }
|
||
|
||
ptpDfltDataSetEntry OBJECT-TYPE
|
||
SYNTAX PtpDfltDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpDefaultDataSet attributes.
|
||
"
|
||
INDEX { ptpDfltDataSetChassis, ptpDfltDataSetSlot}
|
||
::= { ptpDfltDataSetTable 1 }
|
||
|
||
PtpDfltDataSetEntry ::=
|
||
SEQUENCE {
|
||
ptpDfltDataSetChassis
|
||
INTEGER,
|
||
ptpDfltDataSetSlot
|
||
INTEGER,
|
||
ptpDfltDataSetClockId
|
||
OCTET STRING,
|
||
ptpDfltDataSetClockClass
|
||
INTEGER,
|
||
ptpDfltDataSetClockAccuracy
|
||
INTEGER,
|
||
ptpDfltDataSetTimeTraceable
|
||
TrueValue,
|
||
ptpDfltDataSetFreqTraceable
|
||
TrueValue,
|
||
ptpDfltDataSetDomainNumber
|
||
INTEGER
|
||
}
|
||
|
||
ptpDfltDataSetChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpDfltDataSetEntry 1 }
|
||
|
||
ptpDfltDataSetSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpDfltDataSetEntry 2 }
|
||
|
||
ptpDfltDataSetClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Identity (64-bit value).
|
||
The clock id is a hexadecimal format.
|
||
"
|
||
::= { ptpDfltDataSetEntry 3 }
|
||
|
||
ptpDfltDataSetClockClass OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Clock Class
|
||
"
|
||
::= { ptpDfltDataSetEntry 4 }
|
||
|
||
|
||
ptpDfltDataSetClockAccuracy OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
within25ns (32),
|
||
within100ns (33),
|
||
within250ns (34),
|
||
within1000ns (35),
|
||
within2p5us (36),
|
||
within10us (37),
|
||
within25us (38),
|
||
within100us (39),
|
||
within250us (40),
|
||
within1ms (41),
|
||
within2p5ms (42),
|
||
within10ms (43),
|
||
within25ms (44),
|
||
within100ms (45),
|
||
within250ms (46),
|
||
within1sec (47),
|
||
within10sec (48),
|
||
beyond10sec (49),
|
||
unknown (254)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Clock Accuracy
|
||
Following is the Clock Accuracy Table
|
||
32 = within 25 ns
|
||
33 = within 100 ns
|
||
34 = within 250 ns
|
||
35 = within 1000 ns
|
||
36 = within 2.5 us
|
||
37 = within 10 us
|
||
38 = within 25 us
|
||
39 = within 100 us
|
||
40 = within 250 us
|
||
41 = within 1 ms
|
||
42 = within 2.5 ms
|
||
43 = within 10 ms
|
||
44 = within 25 ms
|
||
45 = within 100 ms
|
||
46 = within 250 ms
|
||
47 = within 1 sec
|
||
48 = within 10 sec
|
||
49 = beyond 10 sec
|
||
254 = unknown
|
||
"
|
||
::= { ptpDfltDataSetEntry 5 }
|
||
|
||
ptpDfltDataSetTimeTraceable OBJECT-TYPE
|
||
SYNTAX TrueValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Time Traceability
|
||
1 = true, time traceable
|
||
2 = false, time not traceable
|
||
"
|
||
::= { ptpDfltDataSetEntry 6 }
|
||
|
||
ptpDfltDataSetFreqTraceable OBJECT-TYPE
|
||
SYNTAX TrueValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Frequency Traceability
|
||
1 = true, frequency traceable
|
||
2 = false, frequency not traceable
|
||
"
|
||
::= { ptpDfltDataSetEntry 7 }
|
||
|
||
|
||
ptpDfltDataSetDomainNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP domain number.
|
||
"
|
||
::= { ptpDfltDataSetEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpClockDescrTable
|
||
-- **************************************************************
|
||
|
||
ptpClockDescrTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpClockDescrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpClockDescription.
|
||
"
|
||
::= { statusPtPtp 3 }
|
||
|
||
ptpClockDescrEntry OBJECT-TYPE
|
||
SYNTAX PtpClockDescrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Entries of the PackeTime PTP Management Messages: ptpClockDescription attributes.
|
||
"
|
||
INDEX { ptpClockDescrChassis, ptpClockDescrSlot}
|
||
::= { ptpClockDescrTable 1 }
|
||
|
||
PtpClockDescrEntry ::=
|
||
SEQUENCE {
|
||
ptpClockDescrChassis
|
||
INTEGER,
|
||
ptpClockDescrSlot
|
||
INTEGER,
|
||
ptpClockDescrClockType
|
||
INTEGER,
|
||
ptpClockDescrProtocolAddress
|
||
IpAddress,
|
||
ptpClockDescrManufacturerId
|
||
OCTET STRING,
|
||
ptpClockDescrProfileId
|
||
OCTET STRING
|
||
}
|
||
|
||
ptpClockDescrChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpClockDescrEntry 1 }
|
||
|
||
ptpClockDescrSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpClockDescrEntry 2 }
|
||
|
||
ptpClockDescrClockType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ordinary (32768)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Type
|
||
The value 0x8000 meant Ordinary Clock
|
||
"
|
||
::= { ptpClockDescrEntry 3 }
|
||
|
||
ptpClockDescrProtocolAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP IP Address of PTP port.
|
||
"
|
||
::= { ptpClockDescrEntry 4 }
|
||
|
||
ptpClockDescrManufacturerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Manufacturer Id.
|
||
The format is a 3 bytes array.
|
||
The Manufacturer Id is 00 B0 AE
|
||
"
|
||
::= { ptpClockDescrEntry 5 }
|
||
|
||
ptpClockDescrProfileId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Profile ID.
|
||
The format is 6 bytes array.
|
||
If Telecom-2008, the profile_id is: 00 00 00 00 00 00
|
||
If ITU G8265.1, the profile_id is: 00 19 A7 00 01 00
|
||
"
|
||
::= { ptpClockDescrEntry 6 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpTimeMessageTable
|
||
-- **************************************************************
|
||
|
||
ptpTimeMessageTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpTimeMessageEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpTimeMessage.
|
||
"
|
||
::= { statusPtPtp 4 }
|
||
|
||
ptpTimeMessageEntry OBJECT-TYPE
|
||
SYNTAX PtpTimeMessageEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpTimeMessage attributes
|
||
"
|
||
INDEX { ptpTimeMessageChassis, ptpTimeMessageSlot}
|
||
::= { ptpTimeMessageTable 1 }
|
||
|
||
PtpTimeMessageEntry ::=
|
||
SEQUENCE {
|
||
ptpTimeMessageChassis
|
||
INTEGER,
|
||
ptpTimeMessageSlot
|
||
INTEGER,
|
||
ptpTimeMessageCurrentTimeSec
|
||
OCTET STRING,
|
||
ptpTimeMessageCurrentTimeNSec
|
||
Counter32
|
||
}
|
||
|
||
ptpTimeMessageChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpTimeMessageEntry 1 }
|
||
|
||
ptpTimeMessageSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpTimeMessageEntry 2 }
|
||
|
||
ptpTimeMessageCurrentTimeSec OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Current Time of seconds.
|
||
The current is a 6-byte a hexadecimal format.
|
||
"
|
||
::= { ptpTimeMessageEntry 3 }
|
||
|
||
ptpTimeMessageCurrentTimeNSec OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP fractional Current Time of nanoseconds
|
||
"
|
||
::= { ptpTimeMessageEntry 4 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpPortDataSetTable
|
||
-- **************************************************************
|
||
|
||
ptpPortDataSetTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpPortDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpPortDataSet
|
||
"
|
||
::= { statusPtPtp 5 }
|
||
|
||
ptpPortDataSetEntry OBJECT-TYPE
|
||
SYNTAX PtpPortDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpPortDataSet attributes
|
||
"
|
||
INDEX { ptpPortDataSetChassis, ptpPortDataSetSlot}
|
||
::= { ptpPortDataSetTable 1 }
|
||
|
||
PtpPortDataSetEntry ::=
|
||
SEQUENCE {
|
||
ptpPortDataSetChassis
|
||
INTEGER,
|
||
ptpPortDataSetSlot
|
||
INTEGER,
|
||
ptpPortDataSetClockId
|
||
OCTET STRING,
|
||
ptpPortDataSetPortNumber
|
||
INTEGER,
|
||
ptpPortDataSetPortState
|
||
INTEGER
|
||
}
|
||
|
||
ptpPortDataSetChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpPortDataSetEntry 1 }
|
||
|
||
ptpPortDataSetSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpPortDataSetEntry 2 }
|
||
|
||
ptpPortDataSetClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Identity (64-bit value).
|
||
The port clock id is a hexadecimal format.
|
||
"
|
||
::= { ptpPortDataSetEntry 3 }
|
||
|
||
ptpPortDataSetPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Port Number
|
||
"
|
||
::= { ptpPortDataSetEntry 4 }
|
||
|
||
ptpPortDataSetPortState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notdefined (0),
|
||
initializing (1),
|
||
faulty (2),
|
||
disabled (3),
|
||
listening (4),
|
||
premaster (5),
|
||
master (6),
|
||
passive (7),
|
||
uncalibrated (8),
|
||
slave (9)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Port State
|
||
Following is the PTP Port State Table
|
||
0 = notdefined
|
||
1 = initializing
|
||
2 = faulty
|
||
3 = disabled
|
||
4 = listening
|
||
5 = premaster, it is a state before becoming a Master
|
||
6 = master
|
||
7 = passive
|
||
8 = uncalibrated
|
||
9 = slave
|
||
"
|
||
::= { ptpPortDataSetEntry 5 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP MODULE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtPtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime PTP status and settings.
|
||
"
|
||
::= { setupPtPtp 1 }
|
||
|
||
setPtPtpEntry OBJECT-TYPE
|
||
SYNTAX SetPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The enties of the PackeTime PTP settings and attributes.
|
||
"
|
||
INDEX { setPtPtpChassis, setPtPtpSlot}
|
||
::= { setPtPtpTable 1 }
|
||
|
||
SetPtPtpEntry ::=
|
||
SEQUENCE {
|
||
setPtPtpChassis
|
||
INTEGER,
|
||
setPtPtpSlot
|
||
INTEGER,
|
||
setPtPtpCommit
|
||
INTEGER,
|
||
setPtPtpService
|
||
EnaValue,
|
||
setPtPtpClockId
|
||
OCTET STRING,
|
||
setPtPtpDomain
|
||
INTEGER,
|
||
setPtPtpTimescale
|
||
INTEGER,
|
||
setPtPtpSyncLimit
|
||
INTEGER,
|
||
setPtPtpAnnounceLimit
|
||
INTEGER,
|
||
setPtPtpDelayLimit
|
||
INTEGER,
|
||
setPtPtpDscpState
|
||
EnaValue,
|
||
setPtPtpDscpValue
|
||
INTEGER,
|
||
setPtPtpMaxClient
|
||
INTEGER,
|
||
setPtPtpPortPriority1
|
||
INTEGER,
|
||
setPtPtpPortPriority2
|
||
INTEGER,
|
||
setPtPtpUniLeaseDuration
|
||
INTEGER,
|
||
setPtPtpUniNegotiation
|
||
EnaValue,
|
||
setPtPtpTwostep
|
||
EnaValue,
|
||
setPtPtpProfile
|
||
INTEGER,
|
||
setPtPtpSsmOption
|
||
INTEGER,
|
||
setPtPtpBypass
|
||
OnValue,
|
||
setPtPtpModActive
|
||
YesValue,
|
||
setPtPtpEthRate
|
||
INTEGER,
|
||
setPtPtpVlan
|
||
EnaValue,
|
||
setPtPtpRmvClient
|
||
OCTET STRING
|
||
}
|
||
|
||
setPtPtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtPtpEntry 1 }
|
||
|
||
setPtPtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtPtpEntry 2 }
|
||
|
||
setPtPtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Commit all provisioned parameters, this action makes the parameters active.
|
||
This command will also store the parameters to non-volatile memory.
|
||
|
||
Note: This field only has meaning for a writing (1).
|
||
"
|
||
::= { setPtPtpEntry 3 }
|
||
|
||
setPtPtpService OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP service (daemon) to enable or disable.
|
||
This command is applied to both modules if redundant cards installed.
|
||
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtPtpEntry 4 }
|
||
|
||
setPtPtpClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clockId is the PTP Port Clock Identity (64-bit value).
|
||
The clockid is a hexadecimal format.
|
||
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 5 }
|
||
|
||
setPtPtpDomain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP port domain.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 6 }
|
||
|
||
setPtPtpTimescale OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ptp (1),
|
||
arb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set timescale to 'PTP' or 'ARB'.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 7 }
|
||
|
||
setPtPtpSyncLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-7..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the unicast Sync message rate (2^y).
|
||
The range of the rate value is {-7 to 7}.
|
||
For example, the configurable range is -7, means 128 per second
|
||
"
|
||
::= { setPtPtpEntry 8 }
|
||
|
||
setPtPtpAnnounceLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-3..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set unicast announce message rate (2^y).
|
||
The range of the rate value is {-3 to 4}.
|
||
For example, the configurable range is -3, means 8 per second
|
||
"
|
||
::= { setPtPtpEntry 9 }
|
||
|
||
setPtPtpDelayLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-7..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set unicast delay resp message rate (2^y).
|
||
The range of the rate value is {-7 to 7}.
|
||
For example, the configurable range is -6, means 64 per second
|
||
"
|
||
::= { setPtPtpEntry 10 }
|
||
|
||
setPtPtpDscpState OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the DSCP state to enable or disable.
|
||
"
|
||
::= { setPtPtpEntry 11 }
|
||
|
||
setPtPtpDscpValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..63)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DSCP value.
|
||
"
|
||
::= { setPtPtpEntry 12 }
|
||
|
||
setPtPtpMaxClient OBJECT-TYPE
|
||
SYNTAX INTEGER (64..400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP max clients.
|
||
"
|
||
::= { setPtPtpEntry 13 }
|
||
|
||
setPtPtpPortPriority1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Port Priority 1 {0 to 255}.
|
||
"
|
||
::= { setPtPtpEntry 14 }
|
||
|
||
setPtPtpPortPriority2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Port Priority 2 {0 to 255}.
|
||
"
|
||
::= { setPtPtpEntry 15 }
|
||
|
||
setPtPtpUniLeaseDuration OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Max Dynamic Unicast Lease Interval, {10 to 1000}
|
||
"
|
||
::= { setPtPtpEntry 16 }
|
||
|
||
setPtPtpUniNegotiation OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Unicast Negotiation state: Enable or Disable
|
||
"
|
||
::= { setPtPtpEntry 17 }
|
||
|
||
setPtPtpTwostep OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Two-Step clock state: Enable or Disable
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 18 }
|
||
|
||
setPtPtpProfile OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
telecom2008 (1),
|
||
ituG8265dot1 (4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PTP profile telecom_2008 or itu_g8265_1.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 19 }
|
||
|
||
setPtPtpSsmOption OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
option1 (1),
|
||
option2 (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PTP ssm-option in Option 1 or Option 2.
|
||
"
|
||
::= { setPtPtpEntry 20 }
|
||
|
||
setPtPtpBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock C state, or bypass clock, to enabled or disabled.
|
||
"
|
||
::= { setPtPtpEntry 30 }
|
||
|
||
setPtPtpModActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified module in the redundant pair to be Active.
|
||
Note1: This command only applies when the module in the redundant pair.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtPtpEntry 31 }
|
||
|
||
setPtPtpEthRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all (0),
|
||
r100 (1),
|
||
r1000 (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP port transmission rate.
|
||
all - means auto negotiation capable of both 100M and 1000Mbits/s rate.
|
||
r100 - means auto negotiation capable of only 100Mbit/s rate.
|
||
r1000 - means auto negotiation capable of only 1000Mbit/s rate
|
||
|
||
Note: this setting is only applied to the copper SFP, not fiber.
|
||
If fiber SFP installed, this setting is ignored.
|
||
"
|
||
::= { setPtPtpEntry 32 }
|
||
|
||
setPtPtpVlan OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
|
||
Users must COMMIT for changes into effect.
|
||
"
|
||
::= { setPtPtpEntry 33 }
|
||
|
||
setPtPtpRmvClient OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is an action command and not a configuration command.
|
||
This command remove a client from a ptp client list.
|
||
The clockid is a hexadecimal format.
|
||
|
||
Note: this field only has meansing for write action with proper clock id.
|
||
When it read, it always returns as all zero octet string.
|
||
"
|
||
::= { setPtPtpEntry 34 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP MODULE PORT SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtpPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime PTP ethernet port information.
|
||
"
|
||
::= { setupPtPtp 2 }
|
||
|
||
|
||
setPtpPortEntry OBJECT-TYPE
|
||
SYNTAX SetPtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime PTP ethernet port state and settings information.
|
||
setPtPtpPortChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtPtpPortSlot
|
||
Identifies which slot is being addressed.
|
||
setPtPtpPortNum
|
||
Identifies which port is being addressed.
|
||
setPtPtpPortAddr
|
||
Set the port IP address
|
||
setPtPtpPortMask
|
||
Set the port network mask
|
||
setPtPtpPortGate
|
||
Set the port gateway address
|
||
"
|
||
INDEX { setPtpPortChassis, setPtpPortSlot, setPtpPortNum}
|
||
::= { setPtpPortTable 1 }
|
||
|
||
SetPtpPortEntry ::=
|
||
SEQUENCE {
|
||
setPtpPortChassis
|
||
INTEGER,
|
||
setPtpPortSlot
|
||
INTEGER,
|
||
setPtpPortNum
|
||
INTEGER,
|
||
setPtpPortAddr
|
||
IpAddress,
|
||
setPtpPortMask
|
||
IpAddress,
|
||
setPtpPortGate
|
||
IpAddress
|
||
}
|
||
|
||
setPtpPortChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtpPortEntry 1 }
|
||
|
||
setPtpPortSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtpPortEntry 2 }
|
||
|
||
setPtpPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
|
||
PTPTP ethernet interface number.
|
||
1 = Service Port A
|
||
2 = Maintenance Port
|
||
"
|
||
::= { setPtpPortEntry 3 }
|
||
|
||
setPtpPortAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port IP address
|
||
"
|
||
::= { setPtpPortEntry 4 }
|
||
|
||
setPtpPortMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port network mask
|
||
"
|
||
::= { setPtpPortEntry 5 }
|
||
|
||
setPtpPortGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port gateway address
|
||
"
|
||
::= { setPtpPortEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP VLAN GROUP
|
||
-- ******************************************
|
||
|
||
setPtpVlanTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime PTP vlan attributes.
|
||
The Virtural Local Area Network is implemented per IEEE 802.1Q.
|
||
"
|
||
::= { setupPtPtp 3 }
|
||
|
||
setPtpVlanEntry OBJECT-TYPE
|
||
SYNTAX SetPtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime PTP vlan attributes and settings:
|
||
setPtPtpVlanChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtPtpVlanSlot
|
||
Identifies which slot is being addressed.
|
||
setPtpVlanIndex
|
||
Set the VLAN index number for PTPTP.
|
||
setPtpVlanState
|
||
Enable or Disable of a given VLAN Entry
|
||
setPtpVlanAddr
|
||
VLAN IP Address (If 0.0.0.0, and then SET, this will delete this entry)
|
||
note: This field has to set first with a valid non-zero IP address, if you want to add a new entry
|
||
setPtpVlanMask
|
||
VLAN Network Mask
|
||
setPtpVlanGate
|
||
VLAN Gateway
|
||
setPtpVlanId
|
||
VLAN ID
|
||
setPtpVlanPriority
|
||
VLAN Priority
|
||
Note: The module setPtPtpVlan set must be enabled, and each of the enabled entires
|
||
has meaning.
|
||
"
|
||
INDEX { setPtpVlanChassis, setPtpVlanSlot, setPtpVlanIndex}
|
||
::= { setPtpVlanTable 1 }
|
||
|
||
SetPtpVlanEntry ::=
|
||
SEQUENCE {
|
||
setPtpVlanChassis
|
||
INTEGER,
|
||
setPtpVlanSlot
|
||
INTEGER,
|
||
setPtpVlanIndex
|
||
INTEGER,
|
||
setPtpVlanState
|
||
EnaValue,
|
||
setPtpVlanAddr
|
||
IpAddress,
|
||
setPtpVlanMask
|
||
IpAddress,
|
||
setPtpVlanGate
|
||
IpAddress,
|
||
setPtpVlanId
|
||
INTEGER,
|
||
setPtpVlanPriority
|
||
INTEGER
|
||
}
|
||
|
||
setPtpVlanChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtpVlanEntry 1 }
|
||
|
||
setPtpVlanSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtpVlanEntry 2 }
|
||
|
||
setPtpVlanIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN index number for PTP.
|
||
"
|
||
::= { setPtpVlanEntry 3 }
|
||
|
||
setPtpVlanState OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable or Disable of a given VLAN entry
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 4 }
|
||
|
||
setPtpVlanAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port IP Address
|
||
Note: you must have IP address in order to add or change other fields.
|
||
This field has to set first with a valid non-zero IP address, if you want to add a new entry
|
||
If the IP is 0.0.0.0, and use the SET operation, this mean delete this entry.
|
||
"
|
||
::= { setPtpVlanEntry 5 }
|
||
|
||
setPtpVlanMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port Network Mask
|
||
"
|
||
::= { setPtpVlanEntry 6 }
|
||
|
||
setPtpVlanGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port Gateway Address
|
||
"
|
||
::= { setPtpVlanEntry 7 }
|
||
|
||
setPtpVlanId OBJECT-TYPE
|
||
SYNTAX INTEGER (2..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID (2..4094) for Service Port A
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 8 }
|
||
|
||
|
||
setPtpVlanPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN Priority (0..7) for Service Port A
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 9 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME PTP GETCLIENTLIST GROUP
|
||
-- **************************************************************
|
||
|
||
ptpclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP client list entries.
|
||
|
||
Usage: you need to specify a PTP blade address in ptpclientParmLoc, and
|
||
then execute the command ptpclientCmdXeq first. The PTP client list will be
|
||
saved. This ptpclientTable will display all the PTP client list contents
|
||
of this saved information.
|
||
"
|
||
::= { ptpclient 1 }
|
||
|
||
ptpclientEntry OBJECT-TYPE
|
||
SYNTAX PtpclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP client list containing each PTP client status value.
|
||
ptpclientChassis
|
||
Identifies which chassis is being addressed.
|
||
ptpclientSlot
|
||
Identifies which slot is being addressed.
|
||
ptpclientData
|
||
Reports the contents of the Client data TLV:
|
||
"
|
||
INDEX { ptpclientChassis, ptpclientSlot}
|
||
::= { ptpclientTable 1 }
|
||
|
||
PtpclientEntry ::=
|
||
SEQUENCE {
|
||
ptpclientChassis
|
||
INTEGER,
|
||
ptpclientSlot
|
||
INTEGER,
|
||
ptpclientData
|
||
OCTET STRING
|
||
}
|
||
|
||
ptpclientChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { ptpclientEntry 1 }
|
||
|
||
ptpclientSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { ptpclientEntry 2 }
|
||
|
||
ptpclientData OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(40))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the contents of the Client data TLV:
|
||
INTEGER - mode, 0:dynamic, 1:static
|
||
INTEGER - ip address
|
||
OCTET - clock id
|
||
INTEGER - VLAN ID, if 0xffff, then there is no vlan
|
||
INTEGER - VLAN Priority
|
||
INTEGER - Sync Limit (signed value), if 99, the disable
|
||
INTEGER - Announce Limit (signed value), if 99, the disable
|
||
INTEGER - Delay Limit (signed value), if 99, the disable
|
||
"
|
||
::= { ptpclientEntry 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS (GETCLIENTLIST)
|
||
-- ******************************************
|
||
|
||
ptpclientParmLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the ports VLAN address.
|
||
where
|
||
x is the chassis number: in this case is 1-5,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 1 to 14)
|
||
|
||
For example: 1A6 means this port located at chassis 1, slot 6
|
||
|
||
Note: the user must specify valid PTP address.
|
||
The valid port must be physically installed in the system.
|
||
"
|
||
::= { ptpclient 2 }
|
||
|
||
ptpclientCmdXeq OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current client list in the module.
|
||
The max number of client is 400
|
||
"
|
||
::= { ptpclient 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SYNCE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staSynceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of SyncE status information:
|
||
port_direction, ethernet_mode, rx_ssm, and tx_ssm
|
||
"
|
||
::= { statusSynce 1 }
|
||
|
||
staSynceEntry OBJECT-TYPE
|
||
SYNTAX StaSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of SyncE status attributes.
|
||
"
|
||
INDEX { staSynceChassis, staSynceSlot}
|
||
::= { staSynceTable 1 }
|
||
|
||
StaSynceEntry ::=
|
||
SEQUENCE {
|
||
staSynceChassis
|
||
INTEGER,
|
||
staSynceSlot
|
||
INTEGER,
|
||
staSyncePortDirection
|
||
INTEGER,
|
||
staSynceEthernetMode
|
||
INTEGER,
|
||
staSynceRxSsm
|
||
INTEGER,
|
||
staSynceTxSsm
|
||
INTEGER
|
||
}
|
||
|
||
staSynceChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSynceEntry 1 }
|
||
|
||
staSynceSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSynceEntry 2 }
|
||
|
||
staSyncePortDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
input (1),
|
||
output (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE Port Direction to be either Output or Input.
|
||
The output port is a SyncE master port, and input port is a SyncE slave port.
|
||
"
|
||
::= { staSynceEntry 3 }
|
||
|
||
staSynceEthernetMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
synchronous (1),
|
||
asynchronous (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE operated on Ethernet to be either synchronous or
|
||
asynchronous. It is synchronous mode, when an optical SFP is detected
|
||
at an Ethernet port. It is an asynchronous mode, when an electrical SFP
|
||
is detected at an Ethernet port, or there is no SFP detected.
|
||
"
|
||
::= { staSynceEntry 4 }
|
||
|
||
staSynceRxSsm OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15 | 255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE the current rx ssm value (0 .. 15).
|
||
If 255, SyncE does not receive ESMC messages
|
||
"
|
||
::= { staSynceEntry 5 }
|
||
|
||
staSynceTxSsm OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15 | 255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE the current tx ssm value (0 .. 15).
|
||
If 255, SyncE does not transmit ESMC messages
|
||
"
|
||
::= { staSynceEntry 6 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME SYNCE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setSynceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of SyncE settings.
|
||
"
|
||
::= { setupSynce 1 }
|
||
|
||
setSynceEntry OBJECT-TYPE
|
||
SYNTAX SetSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The enties of the SyncE settings and attributes.
|
||
"
|
||
INDEX { setSynceChassis, setSynceSlot}
|
||
::= { setSynceTable 1 }
|
||
|
||
SetSynceEntry ::=
|
||
SEQUENCE {
|
||
setSynceChassis
|
||
INTEGER,
|
||
setSynceSlot
|
||
INTEGER,
|
||
setSyncePortDirection
|
||
INTEGER,
|
||
setSynceEsmc
|
||
EnaValue,
|
||
setSynceQl
|
||
EnaValue,
|
||
setSynceOutQl
|
||
INTEGER
|
||
}
|
||
|
||
setSynceChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setSynceEntry 1 }
|
||
|
||
setSynceSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setSynceEntry 2 }
|
||
|
||
setSyncePortDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
input (1),
|
||
output (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set SyncE Port Direction to be either Output or Input.
|
||
The output port is a SyncE master port, and input port
|
||
is a SyncE slave port.
|
||
"
|
||
::= { setSynceEntry 3 }
|
||
|
||
setSynceEsmc OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Ethernet Synchronization Message Channel (ESMC)
|
||
state is either Enable or Disable. If ESMC is enabled,
|
||
the ESMC is used; otherwise, it shall not be used.
|
||
"
|
||
::= { setSynceEntry 4 }
|
||
|
||
setSynceQl OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Quality Level (QL, i.e. SSM) in the ESMC is either
|
||
Enabled or Disabled. If QL is enabled, the SSM in the ESMC
|
||
is used; otherwise, it shall not be used.
|
||
"
|
||
::= { setSynceEntry 5 }
|
||
|
||
setSynceOutQl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
bidirectional (1),
|
||
unidirectional (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Output QL mode is either unidirectional or bidirectional.
|
||
In the unidirectional mode, the rx ESMC from the downstream NE is
|
||
ignored. The tx SSM will be determined by the system clock state only.
|
||
In the bidirectional mode, the rx ESMC from the downstream NE is not
|
||
ignored but is used for testing purposes and some interoperability cases.
|
||
"
|
||
::= { setSynceEntry 6 }
|
||
|
||
|
||
END
|