307 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			307 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
NETGEAR-REF-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
-- Netgear Fastpath  Reference MIB
 | 
						|
-- Copyright Netgear Inc (2001-2007) All rights reserved.
 | 
						|
 | 
						|
-- This SNMP Management Information Specification
 | 
						|
-- embodies Netgear Inc confidential and proprietary
 | 
						|
-- intellectual property.  Netgear Inc retains all title
 | 
						|
-- and ownership in the Specification including any revisions.
 | 
						|
 | 
						|
-- This Specification is supplied "AS IS", Netgear Inc
 | 
						|
-- makes no warranty, either expressed or implied,
 | 
						|
-- as to the use, operation, condition, or performance of the
 | 
						|
-- Specification.
 | 
						|
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    MODULE-IDENTITY                     FROM SNMPv2-SMI
 | 
						|
    TEXTUAL-CONVENTION                  FROM SNMPv2-TC
 | 
						|
    enterprises                         FROM RFC1155-SMI;
 | 
						|
    
 | 
						|
    broadcom MODULE-IDENTITY
 | 
						|
        LAST-UPDATED "200705230000Z" -- 23 May 2007 12:00:00 GMT
 | 
						|
        ORGANIZATION "Netgear Inc"
 | 
						|
        CONTACT-INFO ""
 | 
						|
        DESCRIPTION
 | 
						|
          ""
 | 
						|
           
 | 
						|
        -- Revision history.      
 | 
						|
        REVISION
 | 
						|
          "200705230000Z" -- 23 May 2007 12:00:00 GMT
 | 
						|
        DESCRIPTION
 | 
						|
          "Netgear branding related changes."
 | 
						|
        REVISION
 | 
						|
          "200311210000Z" -- 21 Nov 2003 12:00:00 GMT
 | 
						|
        DESCRIPTION
 | 
						|
          "Revisions made for new release."
 | 
						|
        REVISION
 | 
						|
          "200302061200Z" -- 6 February 2003 12:00:00 GMT
 | 
						|
        DESCRIPTION
 | 
						|
          "Updated for release"
 | 
						|
          
 | 
						|
    ::= {  enterprises 4413 }
 | 
						|
 | 
						|
    
 | 
						|
-- New definitions
 | 
						|
-- broadcomProducts         OBJECT IDENTIFIER ::= { broadcom 1 }
 | 
						|
-- ng7000managedswitch                 OBJECT IDENTIFIER ::= { broadcomProducts 1 }
 | 
						|
 
 | 
						|
netgear                 OBJECT IDENTIFIER ::= { enterprises 4526 }
 | 
						|
 | 
						|
--
 | 
						|
-- below are products that defined prior to NMS100 release that they have product code
 | 
						|
-- defined directly above the functions objects
 | 
						|
--
 | 
						|
managedSwitch           OBJECT IDENTIFIER ::= { netgear 1 } 
 | 
						|
vpnrouter               OBJECT IDENTIFIER ::= { netgear 2 }
 | 
						|
carrier                 OBJECT IDENTIFIER ::= { netgear 3 }
 | 
						|
wireless                OBJECT IDENTIFIER ::= { netgear 4 }
 | 
						|
rps                     OBJECT IDENTIFIER ::= { netgear 5 }
 | 
						|
wlanswitch              OBJECT IDENTIFIER ::= { netgear 6 }
 | 
						|
 | 
						|
---
 | 
						|
--- 700 series L2 managed switch
 | 
						|
---
 | 
						|
fsm726s                 OBJECT IDENTIFIER ::= { managedSwitch 1 }
 | 
						|
fsm750s                 OBJECT IDENTIFIER ::= { managedSwitch 2 }
 | 
						|
gsm712                  OBJECT IDENTIFIER ::= { managedSwitch 3 }
 | 
						|
fsm726                  OBJECT IDENTIFIER ::= { managedSwitch 4 }  
 | 
						|
gsm712f                 OBJECT IDENTIFIER ::= { managedSwitch 5 }
 | 
						|
fsm726v2                OBJECT IDENTIFIER ::= { managedSwitch 10 }
 | 
						|
 | 
						|
---
 | 
						|
--- AP
 | 
						|
---
 | 
						|
me103                   OBJECT IDENTIFIER ::= { wireless 1 }
 | 
						|
wg302                   OBJECT IDENTIFIER ::= { wireless 2 }
 | 
						|
wg102                   OBJECT IDENTIFIER ::= { wireless 3 }
 | 
						|
wag302                  OBJECT IDENTIFIER ::= { wireless 4 }
 | 
						|
wag102                  OBJECT IDENTIFIER ::= { wireless 5 }
 | 
						|
---
 | 
						|
--- Added by Stephen Tsai 2-06-2006
 | 
						|
---
 | 
						|
wg302v2                 OBJECT IDENTIFIER ::= { wireless 6 }
 | 
						|
wag302v2                OBJECT IDENTIFIER ::= { wireless 7 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
---
 | 
						|
--- WLAN Switch
 | 
						|
---
 | 
						|
wls538                  OBJECT IDENTIFIER ::= { wlanswitch 1 }
 | 
						|
 | 
						|
---
 | 
						|
--- 7000 series L2/L3 managed switch
 | 
						|
---
 | 
						|
gsm7312                 OBJECT IDENTIFIER ::= { managedSwitch 6 }
 | 
						|
gsm7324                 OBJECT IDENTIFIER ::= { managedSwitch 7 }
 | 
						|
gsm7224                 OBJECT IDENTIFIER ::= { managedSwitch 8 }
 | 
						|
fsm7326p                OBJECT IDENTIFIER ::= { managedSwitch 9 }
 | 
						|
 | 
						|
---********************************************************************
 | 
						|
--- new post-NMS100 SNMP products 
 | 
						|
---
 | 
						|
 | 
						|
--
 | 
						|
-- new post-NMS100 SNMP-enabled products. These products will have their 
 | 
						|
-- functions defined under each generic product category.
 | 
						|
--
 | 
						|
ng7000managedswitch     OBJECT IDENTIFIER ::= { netgear 10 }
 | 
						|
ng700smartswitch        OBJECT IDENTIFIER ::= { netgear 11 }
 | 
						|
ngrouter                OBJECT IDENTIFIER ::= { netgear 12 }
 | 
						|
ngfirewall              OBJECT IDENTIFIER ::= { netgear 13 }
 | 
						|
ngap                    OBJECT IDENTIFIER ::= { netgear 14 }
 | 
						|
ngwlan                  OBJECT IDENTIFIER ::= { netgear 15 }
 | 
						|
ng9000chassisswitch     OBJECT IDENTIFIER ::= { netgear 16 }
 | 
						|
ng700stacksmartswitch   OBJECT IDENTIFIER ::= { netgear 17 } 
 | 
						|
 | 
						|
--
 | 
						|
-- and their sysObjectID will be under a branch on their own
 | 
						|
--
 | 
						|
productID               OBJECT IDENTIFIER ::= { netgear 100 }
 | 
						|
 | 
						|
stackswitch             OBJECT IDENTIFIER ::= { productID 1 }
 | 
						|
l2switch                OBJECT IDENTIFIER ::= { productID 2 }
 | 
						|
l3switch                OBJECT IDENTIFIER ::= { productID 3 }
 | 
						|
smartswitch             OBJECT IDENTIFIER ::= { productID 4 }
 | 
						|
l2Rswitch               OBJECT IDENTIFIER ::= { productID 11 }
 | 
						|
 | 
						|
router                  OBJECT IDENTIFIER ::= { productID 5 }
 | 
						|
firewall                OBJECT IDENTIFIER ::= { productID 6 }
 | 
						|
accesspoint             OBJECT IDENTIFIER ::= { productID 7 }
 | 
						|
wirelessLAN             OBJECT IDENTIFIER ::= { productID 8 }
 | 
						|
chassisswitch           OBJECT IDENTIFIER ::= { productID 9 }
 | 
						|
stacksmartswitch        OBJECT IDENTIFIER ::= { productID 10 }
 | 
						|
 | 
						|
--
 | 
						|
-- Managed switches
 | 
						|
--
 | 
						|
fsm7328s                OBJECT IDENTIFIER ::= { stackswitch 1 }
 | 
						|
fsm7352s                OBJECT IDENTIFIER ::= { stackswitch 2 }
 | 
						|
gsm7328s                OBJECT IDENTIFIER ::= { stackswitch 3 }
 | 
						|
gsm7352s                OBJECT IDENTIFIER ::= { stackswitch 4 }
 | 
						|
fsm7352ps               OBJECT IDENTIFIER ::= { stackswitch 5 }
 | 
						|
fsm7328ps               OBJECT IDENTIFIER ::= { stackswitch 8 }
 | 
						|
gsm7328fs               OBJECT IDENTIFIER ::= { stackswitch 7 }
 | 
						|
gsm7228ps               OBJECT IDENTIFIER ::= { stackswitch 9 }
 | 
						|
gsm7252ps               OBJECT IDENTIFIER ::= { stackswitch 10 }
 | 
						|
fsm7226rs               OBJECT IDENTIFIER ::= { stackswitch 11 }
 | 
						|
fsm7250rs               OBJECT IDENTIFIER ::= { stackswitch 12 }
 | 
						|
gsm7328se               OBJECT IDENTIFIER ::= { stackswitch 13 }
 | 
						|
gsm7352se               OBJECT IDENTIFIER ::= { stackswitch 14 }
 | 
						|
xsm7224s                OBJECT IDENTIFIER ::= { stackswitch 15 }
 | 
						|
 | 
						|
m530028gpoe             OBJECT IDENTIFIER ::= { stackswitch 16 }
 | 
						|
m530052gpoe             OBJECT IDENTIFIER ::= { stackswitch 17 }
 | 
						|
m530028g3               OBJECT IDENTIFIER ::= { stackswitch 18 }
 | 
						|
m530052g3               OBJECT IDENTIFIER ::= { stackswitch 19 }
 | 
						|
m530028gf3              OBJECT IDENTIFIER ::= { stackswitch 20 }
 | 
						|
m530028g                OBJECT IDENTIFIER ::= { stackswitch 21 }
 | 
						|
m530052g                OBJECT IDENTIFIER ::= { stackswitch 22 }
 | 
						|
 | 
						|
gsm7312v2               OBJECT IDENTIFIER ::= { l3switch 1 }
 | 
						|
gsm7324v2               OBJECT IDENTIFIER ::= { l3switch 2 }
 | 
						|
xsm7312                 OBJECT IDENTIFIER ::= { l3switch 3 }
 | 
						|
gsm7324p                OBJECT IDENTIFIER ::= { l3switch 4 }
 | 
						|
 | 
						|
gsm7224r                OBJECT IDENTIFIER ::= { l2Rswitch 1 }
 | 
						|
gsm7248r                OBJECT IDENTIFIER ::= { l2Rswitch 2 }
 | 
						|
gsm7224rp               OBJECT IDENTIFIER ::= { l2Rswitch 3 }
 | 
						|
gsm7248rp               OBJECT IDENTIFIER ::= { l2Rswitch 4 }
 | 
						|
gsm7224v2               OBJECT IDENTIFIER ::= { l2Rswitch 5 }
 | 
						|
gsm7248v2               OBJECT IDENTIFIER ::= { l2Rswitch 6 }
 | 
						|
 | 
						|
gsm7212f                OBJECT IDENTIFIER ::= { l2Rswitch 7 }
 | 
						|
gsm5212p                OBJECT IDENTIFIER ::= { l2Rswitch 8 }
 | 
						|
gsm7212p                OBJECT IDENTIFIER ::= { l2Rswitch 9 }
 | 
						|
gsm7224p                OBJECT IDENTIFIER ::= { l2Rswitch 10 }
 | 
						|
 | 
						|
m4100-26g               OBJECT IDENTIFIER ::= { l2Rswitch 16 }
 | 
						|
m4100-50g               OBJECT IDENTIFIER ::= { l2Rswitch 17 }
 | 
						|
m4100-26-poe            OBJECT IDENTIFIER ::= { l2Rswitch 18 }
 | 
						|
m4100-26g-poe           OBJECT IDENTIFIER ::= { l2Rswitch 19 }
 | 
						|
m4100-50g-poe           OBJECT IDENTIFIER ::= { l2Rswitch 20 }
 | 
						|
m4100-50-poe            OBJECT IDENTIFIER ::= { l2Rswitch 21 }
 | 
						|
m4100-d12g              OBJECT IDENTIFIER ::= { l2Rswitch 22 }
 | 
						|
m4100-d10-poe           OBJECT IDENTIFIER ::= { l2Rswitch 23 }
 | 
						|
m4100-12gf              OBJECT IDENTIFIER ::= { l2Rswitch 24 }
 | 
						|
m4100-d12g-poe          OBJECT IDENTIFIER ::= { l2Rswitch 25 }
 | 
						|
m4100-12g-poe           OBJECT IDENTIFIER ::= { l2Rswitch 26 }
 | 
						|
m4100-24g-poe           OBJECT IDENTIFIER ::= { l2Rswitch 27 }
 | 
						|
 | 
						|
-- 
 | 
						|
-- GSM7324, GSM7312, FSM7326P, and GSM7224, are using two different styles
 | 
						|
-- of FP private MIB: dedicate and generic. For those using dedicated one, the sysOID
 | 
						|
-- are assigned to "gsm7324", "gsm7312, "fsm7326p", and "gsm7224". For the one using 
 | 
						|
-- generic MIB, the new OIDs are has a "i" in the end.
 | 
						|
--
 | 
						|
gsm7312i                OBJECT IDENTIFIER ::= { l3switch 5 }
 | 
						|
gsm7324i                OBJECT IDENTIFIER ::= { l3switch 6 }
 | 
						|
fsm7326pi               OBJECT IDENTIFIER ::= { l3switch 7 }
 | 
						|
 | 
						|
gsm7248                 OBJECT IDENTIFIER ::= { l2switch 1 }
 | 
						|
gsm7212                 OBJECT IDENTIFIER ::= { l2switch 2 }
 | 
						|
gsm7224i                OBJECT IDENTIFIER ::= { l2switch 3 }
 | 
						|
fsm7226                 OBJECT IDENTIFIER ::= { l2switch 4 } 
 | 
						|
 | 
						|
gcm9000                 OBJECT IDENTIFIER ::= { chassisswitch 1 }
 | 
						|
xcm8903                 OBJECT IDENTIFIER ::= { chassisswitch 6 }
 | 
						|
 | 
						|
---
 | 
						|
--- new SNMP-enabled smartswitch
 | 
						|
---
 | 
						|
gs748t                  OBJECT IDENTIFIER ::= { smartswitch 1 }
 | 
						|
fs726t                  OBJECT IDENTIFIER ::= { smartswitch 2 }
 | 
						|
gs716t                  OBJECT IDENTIFIER ::= { smartswitch 3 }
 | 
						|
fs750t                  OBJECT IDENTIFIER ::= { smartswitch 4 }
 | 
						|
gs724t                  OBJECT IDENTIFIER ::= { smartswitch 5 }
 | 
						|
fs726tp                 OBJECT IDENTIFIER ::= { smartswitch 6 }
 | 
						|
fs728tp                 OBJECT IDENTIFIER ::= { smartswitch 7 }  
 | 
						|
gs108t                  OBJECT IDENTIFIER ::= { smartswitch 8 }
 | 
						|
gs108tp                 OBJECT IDENTIFIER ::= { smartswitch 9 }
 | 
						|
gs724tp                 OBJECT IDENTIFIER ::= { smartswitch 10 }
 | 
						|
gs748tp                 OBJECT IDENTIFIER ::= { smartswitch 11 }
 | 
						|
gs724tr                 OBJECT IDENTIFIER ::= { smartswitch 12 }
 | 
						|
gs748tr                 OBJECT IDENTIFIER ::= { smartswitch 13 }
 | 
						|
gs716tv2                OBJECT IDENTIFIER ::= { smartswitch 16 }
 | 
						|
gs724tv3                OBJECT IDENTIFIER ::= { smartswitch 17 }
 | 
						|
gs108tv2                OBJECT IDENTIFIER ::= { smartswitch 18 }
 | 
						|
gs110tp                 OBJECT IDENTIFIER ::= { smartswitch 19 }
 | 
						|
fs728tpv2               OBJECT IDENTIFIER ::= { smartswitch 20 }
 | 
						|
gs716tv3                OBJECT IDENTIFIER ::= { smartswitch 31 }
 | 
						|
gs724tv4                OBJECT IDENTIFIER ::= { smartswitch 32 }
 | 
						|
gs748tv5                OBJECT IDENTIFIER ::= { smartswitch 33 }
 | 
						|
xs712t                  OBJECT IDENTIFIER ::= { smartswitch 30 }
 | 
						|
 | 
						|
 | 
						|
fs728ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 1 }
 | 
						|
fs752ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 2 }
 | 
						|
fs752tps                OBJECT IDENTIFIER ::= { stacksmartswitch 3 }
 | 
						|
gs724ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 4 }
 | 
						|
gs748ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 5 }
 | 
						|
gs752ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 12 }
 | 
						|
gs728ts                 OBJECT IDENTIFIER ::= { stacksmartswitch 11 }
 | 
						|
gs752tstps              OBJECT IDENTIFIER ::= { stacksmartswitch 8 }
 | 
						|
gs728tps                OBJECT IDENTIFIER ::= { stacksmartswitch 13 }
 | 
						|
gs752tps                OBJECT IDENTIFIER ::= { stacksmartswitch 14 }
 | 
						|
gs752txs                OBJECT IDENTIFIER ::= { stacksmartswitch 10 }
 | 
						|
gs728txs                OBJECT IDENTIFIER ::= { stacksmartswitch 15 }
 | 
						|
s3300-28x		OBJECT IDENTIFIER ::= { stacksmartswitch 16 }
 | 
						|
s3300-28x-poe		OBJECT IDENTIFIER ::= { stacksmartswitch 17 }
 | 
						|
s3300-52x		OBJECT IDENTIFIER ::= { stacksmartswitch 18 }
 | 
						|
s3300-52x-poe		OBJECT IDENTIFIER ::= { stacksmartswitch 19 }
 | 
						|
 | 
						|
---
 | 
						|
--- new SNMP-enabled business router/firewall
 | 
						|
---
 | 
						|
fvx538                  OBJECT IDENTIFIER ::= { router 1 }
 | 
						|
fvs338                  OBJECT IDENTIFIER ::= { router 2 }
 | 
						|
fvg318                  OBJECT IDENTIFIER ::= { router 3 }
 | 
						|
fvs336g                 OBJECT IDENTIFIER ::= { router 4 }
 | 
						|
 | 
						|
---
 | 
						|
--- new SNMP-enabled firewall
 | 
						|
---
 | 
						|
fwag114                 OBJECT IDENTIFIER ::= { firewall 3 }
 | 
						|
fvs124g                 OBJECT IDENTIFIER ::= { firewall 4 }
 | 
						|
fvs318v3                OBJECT IDENTIFIER ::= { firewall 5 }
 | 
						|
dgfv338                 OBJECT IDENTIFIER ::= { firewall 6 }
 | 
						|
 | 
						|
---
 | 
						|
--- new SNMP-enabled AP
 | 
						|
---
 | 
						|
wpn802                  OBJECT IDENTIFIER ::= { accesspoint 1 }
 | 
						|
wg312                   OBJECT IDENTIFIER ::= { accesspoint 2 }
 | 
						|
wag312                  OBJECT IDENTIFIER ::= { accesspoint 3 }
 | 
						|
 | 
						|
---
 | 
						|
--- new WLAN
 | 
						|
---
 | 
						|
 
 | 
						|
-- New Textual Conventions
 | 
						|
AgentPortMask ::= TEXTUAL-CONVENTION
 | 
						|
   STATUS  current
 | 
						|
   DESCRIPTION
 | 
						|
       "Each octet within this value specifies a set of eight
 | 
						|
        ports, with the first octet specifying ports 1 through
 | 
						|
        8, the second octet specifying ports 9 through 16, etc.
 | 
						|
        Within each octet, the most significant bit represents
 | 
						|
        the lowest numbered port, and the least significant bit
 | 
						|
        represents the highest numbered port.  Thus, each port
 | 
						|
        of the bridge is represented by a single bit within the
 | 
						|
        value of this object.  If that bit has a value of '1'
 | 
						|
        then that port is included in the set of ports; the port
 | 
						|
        is not included if its bit has a value of '0'
 | 
						|
             
 | 
						|
        When setting this value, the system will ignore 
 | 
						|
        configuration for ports not between the first and last 
 | 
						|
        valid ports.  Configuration of any port numbers between 
 | 
						|
        this range that are not valid ports return a failure 
 | 
						|
        message, but will still apply configuration for valid 
 | 
						|
        ports."
 | 
						|
   SYNTAX  OCTET STRING
 | 
						|
 | 
						|
 | 
						|
END
 |