SFLOW-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
      
 | 
						|
      MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises 
 | 
						|
              FROM SNMPv2-SMI
 | 
						|
      TEXTUAL-CONVENTION
 | 
						|
              FROM SNMPv2-TC
 | 
						|
      SnmpAdminString
 | 
						|
              FROM SNMP-FRAMEWORK-MIB
 | 
						|
      OwnerString
 | 
						|
              FROM RMON-MIB
 | 
						|
      InetAddressType, InetAddress
 | 
						|
              FROM INET-ADDRESS-MIB
 | 
						|
      MODULE-COMPLIANCE, OBJECT-GROUP
 | 
						|
              FROM SNMPv2-CONF;
 | 
						|
 | 
						|
      sFlowMIB  MODULE-IDENTITY 
 | 
						|
        LAST-UPDATED "200309240000Z"   -- September 24, 2003
 | 
						|
        ORGANIZATION "sFlow.org"
 | 
						|
        CONTACT-INFO
 | 
						|
               "Peter Phaal
 | 
						|
                sFlow.org
 | 
						|
                http://www.sflow.org/
 | 
						|
 | 
						|
                Tel:  +1-415-283-3260
 | 
						|
                Email: peter.phaal@sflow.org"
 | 
						|
 | 
						|
        DESCRIPTION
 | 
						|
                "The MIB module for managing the generation and transportation
 | 
						|
                 of sFlow data records."
 | 
						|
 | 
						|
        --
 | 
						|
        -- Revision History
 | 
						|
        --
 | 
						|
 | 
						|
        REVISION    "200310180000Z"     -- November 18, 2003
 | 
						|
        DESCRIPTION
 | 
						|
                "Version 1.3 (draft 5)
 | 
						|
 | 
						|
                 Allow set to SFlowReceiver if it doesn't change
 | 
						|
                 value."
 | 
						|
 | 
						|
        REVISION    "200309240000Z"     --  September 24, 2003
 | 
						|
        DESCRIPTION
 | 
						|
                "Version 1.3 (draft 4)
 | 
						|
 | 
						|
                 Default value of sFlowRcvrAddress should be '00000000' h.
 | 
						|
                 Default value of sFlowCpReceiver should be 0."
 | 
						|
 | 
						|
        REVISION    "200304080000Z"     --  April 8, 2003
 | 
						|
        DESCRIPTION
 | 
						|
                "Version 1.3 (draft 3)
 | 
						|
 | 
						|
                 Clarify semantics of counter polling interval, 
 | 
						|
                 sFlowCpInterval."
 | 
						|
 | 
						|
        REVISION    "200209170000Z"     -- September 17, 2002
 | 
						|
        DESCRIPTION
 | 
						|
                "Version 1.3 (draft 2)
 | 
						|
 | 
						|
                 Adds support for multiple sFlow samplers per sFlowDataSource.
 | 
						|
                 Moved to sflow.org enterprise number.
 | 
						|
                 Splits flow sampling, counter polling and receiver 
 | 
						|
                 specification into separate tables."
 | 
						|
 | 
						|
        REVISION    "200107310000Z"     -- July 31, 2001 
 | 
						|
        DESCRIPTION 
 | 
						|
                "Version 1.2
 | 
						|
 | 
						|
                 Brings MIB into SMI v2 compliance."
 | 
						|
 | 
						|
        REVISION    "200105010000Z"      -- May 1, 2001
 | 
						|
        DESCRIPTION
 | 
						|
                 "Version 1.1
 | 
						|
 | 
						|
                  Adds sfDatagramVersion."
 | 
						|
 | 
						|
        ::= { enterprises 14706 1 }
 | 
						|
 | 
						|
      sFlowAgent OBJECT IDENTIFIER ::= { sFlowMIB 1 }
 | 
						|
 | 
						|
      SFlowDataSource ::= TEXTUAL-CONVENTION
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Identifies a source of sFlow data.
 | 
						|
 | 
						|
                The following data source types are currently defined:
 | 
						|
 | 
						|
                - ifIndex.<I>
 | 
						|
                SFlowDataSources of this traditional form are called
 | 
						|
                'port-based'. Ideally the sampling entity will perform 
 | 
						|
                sampling on all flows originating from or destined to 
 | 
						|
                the specified interface. However, if the switch architecture 
 | 
						|
                only allows input or output sampling then the sampling agent 
 | 
						|
                is permitted to only sample input flows input or output flows. 
 | 
						|
                Each packet must only be considered once for sampling, 
 | 
						|
                irrespective of the number of ports it will be forwarded to.
 | 
						|
                Note: Port 0 is used to indicate that all ports on the device
 | 
						|
                      are represented by a single data source.
 | 
						|
                      - sFlowFsPacketSamplingRate applies to all ports on the
 | 
						|
                        device capable of packet sampling.
 | 
						|
 | 
						|
                - smonVlanDataSource.<V>
 | 
						|
                An SFlowDataSource of this form refers to a 'Packet-based VLAN'
 | 
						|
                and is called a 'VLAN-based' dataSource. <V> is the VLAN
 | 
						|
                ID as defined by the IEEE 802.1Q standard. The
 | 
						|
                value is between 1 and 4094 inclusive, and it represents
 | 
						|
                an 802.1Q VLAN-ID with global scope within a given
 | 
						|
                bridged domain.
 | 
						|
                Sampling is performed on all packets received that are part
 | 
						|
                of the specified VLAN (no matter which port they arrived on).
 | 
						|
                Each packet will only be considered once for sampling,
 | 
						|
                irrespective of the number of ports it will be forwarded to.
 | 
						|
                
 | 
						|
                - entPhysicalEntry.<N>
 | 
						|
                An SFlowDataSource of this form refers to a physical entity 
 | 
						|
                within the agent (e.g. entPhysicalClass = backplane(4)) and 
 | 
						|
                is called an 'entity-based' dataSource. Sampling is performed 
 | 
						|
                on all packets entering the resource (e.g. If the backplane 
 | 
						|
                is being sampled, all packets transmitted onto the backplane 
 | 
						|
                will be considered as single candidates for sampling 
 | 
						|
                irrespective of the number of ports they ultimately reach).
 | 
						|
 | 
						|
                Note: Since each SFlowDataSource operates independently a 
 | 
						|
                      packet that crosses multiple DataSources may generate 
 | 
						|
                      multiple flow records."
 | 
						|
              SYNTAX      OBJECT IDENTIFIER
 | 
						|
 | 
						|
      SFlowInstance ::= TEXTUAL-CONVENTION
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "If more than one sFlow sampler is available for this
 | 
						|
                 SFlowDataSource then individual samplers are distinguished
 | 
						|
                 using the SFlowInstance variable. The value of 
 | 
						|
                 SFlowInstance ranges from 1..n where n is the number of
 | 
						|
                 samplers associated with this SFlowDataSource.
 | 
						|
 | 
						|
                 Note: Each sFlow sampler instance must operate
 | 
						|
                       independently of all other instances. Setting
 | 
						|
                       an attribute of one sampler must not alter the
 | 
						|
                       the behavior and settings of other sampler
 | 
						|
                       instances."
 | 
						|
              SYNTAX      Integer32 (1..65535)
 | 
						|
 | 
						|
      SFlowReceiver ::= TEXTUAL-CONVENTION
 | 
						|
              STATUS       current
 | 
						|
              DESCRIPTION
 | 
						|
                "Identify the sFlow receiver associated with this resource.
 | 
						|
 | 
						|
                 A value of zero indicates that this resource is available.
 | 
						|
                 If non-zero the value must correspond to a valid, active 
 | 
						|
                 sFlowRcvrIndex.
 | 
						|
 | 
						|
                 If the value is currently zero it may be set to any
 | 
						|
                 active entry in the sFlowRcvrTable. If the value is
 | 
						|
                 not zero then a set to anything other than zero or
 | 
						|
                 its current value will result in an SNMP error (bad value).
 | 
						|
 | 
						|
                 Setting to zero frees the resource and returns all the
 | 
						|
                 values in this entry to their default values.
 | 
						|
 | 
						|
                 If an entry in the sFlowRcvrTable expires, either
 | 
						|
                 because the sFlowRcvrOwner is set to the empty
 | 
						|
                 string or because the sFlowRcvrTimeout reaches zero, then
 | 
						|
                 the agent must mark all associated resources as available
 | 
						|
                 (by setting the associated SFlowReceiver entry to zero)
 | 
						|
                 and all values in these records must be restored to their
 | 
						|
                 default values.
 | 
						|
 | 
						|
                 This mechanism provides no enforcement and relies on the
 | 
						|
                 cooperation of management entities in order to ensure that
 | 
						|
                 competition for a resource is fairly resolved. A management
 | 
						|
                 entity should not make any changes to a resource
 | 
						|
                 without first aquiring it by successfully writing its
 | 
						|
                 sFlowRcvrIndex value as the SFlowReceiver for the resource."
 | 
						|
              SYNTAX       Integer32
 | 
						|
      
 | 
						|
      sFlowVersion OBJECT-TYPE
 | 
						|
              SYNTAX      SnmpAdminString
 | 
						|
              MAX-ACCESS  read-only
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Uniquely identifies the version and implementation of this MIB.
 | 
						|
                 The version string must have the following structure:
 | 
						|
                    <MIB Version>;<Organization>;<Software Revision>
 | 
						|
                 where:
 | 
						|
                    <MIB Version>  must be '1.3', the version of this MIB.
 | 
						|
                    <Organization> the name of the organization responsible
 | 
						|
                                     for the agent implementation.
 | 
						|
                    <Revision>     the specific software build of this agent.
 | 
						|
 | 
						|
                 As an example, the string '1.3;InMon Corp.;2.1.1' indicates
 | 
						|
                 that this agent implements version '1.2' of the SFLOW MIB, that
 | 
						|
                 it was developed by 'InMon Corp.' and that the software build
 | 
						|
                 is '2.1.1'.
 | 
						|
 | 
						|
                 The MIB Version will change with each revision of the SFLOW
 | 
						|
                 MIB.
 | 
						|
 | 
						|
                 Management entities must check the MIB Version and not attempt
 | 
						|
                 to manage agents with MIB Versions greater than that for which
 | 
						|
                 they were designed.
 | 
						|
 | 
						|
                 Note: The sFlow Datagram Format has an independent version
 | 
						|
                       number which may change independently from <MIB Version>.
 | 
						|
                       <MIB Version> applies to the structure and semantics of
 | 
						|
                       the SFLOW MIB only."
 | 
						|
              DEFVAL { "1.3;;" }
 | 
						|
              ::= { sFlowAgent 1 }
 | 
						|
 | 
						|
      sFlowAgentAddressType OBJECT-TYPE
 | 
						|
              SYNTAX      InetAddressType
 | 
						|
              MAX-ACCESS  read-only
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The address type of the address associated with this agent.
 | 
						|
                 Only ipv4 and ipv6 types are supported."
 | 
						|
              ::= { sFlowAgent 2 }
 | 
						|
 | 
						|
      sFlowAgentAddress OBJECT-TYPE
 | 
						|
              SYNTAX      InetAddress
 | 
						|
              MAX-ACCESS  read-only
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The IP address associated with this agent. In the case of a
 | 
						|
                 multi-homed agent, this should be the loopback address of the
 | 
						|
                 agent. The sFlowAgent address must provide SNMP connectivity
 | 
						|
                 to the agent. The address should be an invariant that does not
 | 
						|
                 change as interfaces are reconfigured, enabled, disabled,
 | 
						|
                 added or removed. A manager should be able to use the 
 | 
						|
                 sFlowAgentAddress as a unique key that will identify this
 | 
						|
                 agent over extended periods of time so that a history can
 | 
						|
                 be maintained."
 | 
						|
             ::= { sFlowAgent 3 }   
 | 
						|
 | 
						|
      -- 
 | 
						|
      -- Receiver Table
 | 
						|
      --
 | 
						|
 | 
						|
      sFlowRcvrTable OBJECT-TYPE
 | 
						|
              SYNTAX      SEQUENCE OF SFlowRcvrEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "A table of the receivers of sFlow information."
 | 
						|
              ::= { sFlowAgent 4 }
 | 
						|
 | 
						|
      sFlowRcvrEntry OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowRcvrEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Attributes of an sFlow Receiver."
 | 
						|
              INDEX { sFlowRcvrIndex }
 | 
						|
              ::= { sFlowRcvrTable 1 }
 | 
						|
 | 
						|
      SFlowRcvrEntry ::= SEQUENCE {
 | 
						|
              sFlowRcvrIndex                    Integer32,
 | 
						|
              sFlowRcvrOwner                    OwnerString,
 | 
						|
              sFlowRcvrTimeout                  Integer32,
 | 
						|
              sFlowRcvrMaximumDatagramSize      Integer32,
 | 
						|
              sFlowRcvrAddressType              InetAddressType,
 | 
						|
              sFlowRcvrAddress                  InetAddress,
 | 
						|
              sFlowRcvrPort                     Integer32,
 | 
						|
              sFlowRcvrDatagramVersion          Integer32
 | 
						|
      }
 | 
						|
 | 
						|
      sFlowRcvrIndex OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32 (1..65535)
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Index into sFlowReceiverTable."
 | 
						|
              ::= { sFlowRcvrEntry 1 }
 | 
						|
 | 
						|
      sFlowRcvrOwner OBJECT-TYPE
 | 
						|
              SYNTAX      OwnerString
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The entity making use of this sFlowRcvrTable entry. The empty
 | 
						|
                 string indicates that the entry is currently unclaimed.
 | 
						|
                 An entity wishing to claim an sFlowRcvrTable entry must ensure
 | 
						|
                 that the entry is unclaimed before trying to claim it.
 | 
						|
                 The entry is claimed by setting the owner string. The entry
 | 
						|
                 must be claimed before any changes can be made to other sampler
 | 
						|
                 objects.
 | 
						|
 | 
						|
                 In order to avoid a race condition, the entity taking control
 | 
						|
                 of the sampler must set both the owner and a value for
 | 
						|
                 sFlowRcvrTimeout in the same SNMP set request.
 | 
						|
 | 
						|
                 When a management entity is finished using the sampler,
 | 
						|
                 it should set the value of sFlowRcvrOwner back to unclaimed. 
 | 
						|
                 The agent must restore all other entities this row to their
 | 
						|
                 default values when the owner is set to unclaimed. It must
 | 
						|
                 also free all other resources associated with this 
 | 
						|
                 sFlowRcvrTable entry.
 | 
						|
 | 
						|
                 This mechanism provides no enforcement and relies on the
 | 
						|
                 cooperation of management entities in order to ensure that
 | 
						|
                 competition for a receiver entry is fairly resolved."
 | 
						|
              DEFVAL { "" }
 | 
						|
              ::= { sFlowRcvrEntry 2 }
 | 
						|
 | 
						|
      sFlowRcvrTimeout OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The time (in seconds) remaining before the sampler is released
 | 
						|
                 and stops sampling. When set, the owner establishes control
 | 
						|
                 for the specified period. When read, the remaining time in the
 | 
						|
                 interval is returned.
 | 
						|
 | 
						|
                 A management entity wanting to maintain control of the sampler
 | 
						|
                 is responsible for setting a new value before the old one
 | 
						|
                 expires.
 | 
						|
 | 
						|
                 When the interval expires, the agent is responsible for 
 | 
						|
                 restoring all other entities in this row to their default 
 | 
						|
                 values. It must also free all other resources associated with
 | 
						|
                 this sFlowRcvrTable entry." 
 | 
						|
              DEFVAL { 0 }
 | 
						|
              ::= { sFlowRcvrEntry 3 } 
 | 
						|
 | 
						|
      sFlowRcvrMaximumDatagramSize OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                 "The maximum number of data bytes that can be sent in a single
 | 
						|
                  sample datagram. The manager should set this value to avoid
 | 
						|
                  fragmentation of the sFlow datagrams."
 | 
						|
              DEFVAL { 1400 }
 | 
						|
              ::= { sFlowRcvrEntry 4 }
 | 
						|
 | 
						|
      sFlowRcvrAddressType OBJECT-TYPE
 | 
						|
              SYNTAX      InetAddressType
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The type of sFlowRcvrCollectorAddress."
 | 
						|
              DEFVAL { ipv4 }
 | 
						|
              ::= { sFlowRcvrEntry 5 }
 | 
						|
 | 
						|
      sFlowRcvrAddress OBJECT-TYPE
 | 
						|
              SYNTAX      InetAddress
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The IP address of the sFlow collector.
 | 
						|
                 If set to 0.0.0.0 not sFlow datagrams will be sent."
 | 
						|
              DEFVAL { '00000000'h }  -- 0.0.0.0
 | 
						|
              ::= { sFlowRcvrEntry 6 }
 | 
						|
 | 
						|
      sFlowRcvrPort OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The destination port for sFlow datagrams."
 | 
						|
              DEFVAL { 6343 }
 | 
						|
              ::= { sFlowRcvrEntry 7 }
 | 
						|
 | 
						|
      sFlowRcvrDatagramVersion OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The version of sFlow datagrams that should be sent.
 | 
						|
 | 
						|
                 When set to a value not support by the agent, the agent should
 | 
						|
                 adjust the value to the highest supported value less than the
 | 
						|
                 requested value, or return an SNMP bad value error if no 
 | 
						|
                 such value exists."
 | 
						|
              DEFVAL { 5 }
 | 
						|
              ::= { sFlowRcvrEntry 8 }                
 | 
						|
 | 
						|
      -- 
 | 
						|
      -- Flow Sampling Table
 | 
						|
      --
 | 
						|
 | 
						|
      sFlowFsTable OBJECT-TYPE
 | 
						|
              SYNTAX      SEQUENCE OF SFlowFsEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "A table of the flow samplers within a device."
 | 
						|
              ::= { sFlowAgent 5 }
 | 
						|
 | 
						|
      sFlowFsEntry OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowFsEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Attributes of a flow sampler."
 | 
						|
              INDEX { sFlowFsDataSource, sFlowFsInstance }
 | 
						|
              ::= { sFlowFsTable 1 }
 | 
						|
 | 
						|
      SFlowFsEntry ::= SEQUENCE {
 | 
						|
              sFlowFsDataSource               SFlowDataSource,
 | 
						|
              sFlowFsInstance                 SFlowInstance,
 | 
						|
              sFlowFsReceiver                 SFlowReceiver,
 | 
						|
              sFlowFsPacketSamplingRate       Integer32,
 | 
						|
              sFlowFsMaximumHeaderSize        Integer32
 | 
						|
      }
 | 
						|
 | 
						|
      sFlowFsDataSource OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowDataSource
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "sFlowDataSource for this flow sampler."
 | 
						|
              ::= { sFlowFsEntry 1 }
 | 
						|
 | 
						|
      sFlowFsInstance OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowInstance
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The sFlow instance for this flow sampler."
 | 
						|
              ::= { sFlowFsEntry 2 }
 | 
						|
 | 
						|
      sFlowFsReceiver OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowReceiver
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The SFlowReceiver for this flow sampler."
 | 
						|
              DEFVAL { 0 }
 | 
						|
              ::= { sFlowFsEntry 3 } 
 | 
						|
 | 
						|
      sFlowFsPacketSamplingRate OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The statistical sampling rate for packet sampling from this
 | 
						|
                 source. 
 | 
						|
 | 
						|
                 Set to N to sample 1/Nth of the packets in the monitored flows.
 | 
						|
                 An agent should choose its own algorithm to introduce variance
 | 
						|
                 into the sampling so that exactly every Nth packet is not
 | 
						|
                 counted. A sampling rate of 1 counts all packets. A sampling
 | 
						|
                 rate of 0 disables sampling.
 | 
						|
                 
 | 
						|
                 The agent is permitted to have minimum and maximum allowable
 | 
						|
                 values for the sampling rate. A minimum rate lets the agent
 | 
						|
                 designer set an upper bound on the overhead associated with
 | 
						|
                 sampling, and a maximum rate may be the result of hardware
 | 
						|
                 restrictions (such as counter size). In addition not all values
 | 
						|
                 between the maximum and minimum may be realizable as the 
 | 
						|
                 sampling rate (again because of implementation considerations).
 | 
						|
 | 
						|
                 When the sampling rate is set the agent is free to adjust the
 | 
						|
                 value so that it lies between the maximum and minimum values
 | 
						|
                 and has the closest achievable value.
 | 
						|
 | 
						|
                 When read, the agent must return the actual sampling rate it
 | 
						|
                 will be using (after the adjustments previously described). The
 | 
						|
                 sampling algorithm must converge so that over time the number
 | 
						|
                 of packets sampled approaches 1/Nth of the total number of
 | 
						|
                 packets in the monitored flows."
 | 
						|
              DEFVAL { 0 }
 | 
						|
              ::= { sFlowFsEntry 4 }
 | 
						|
 | 
						|
      sFlowFsMaximumHeaderSize OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The maximum number of bytes that should be copied from a
 | 
						|
                 sampled packet. The agent may have an internal maximum and
 | 
						|
                 minimum permissible sizes. If an attempt is made to set this 
 | 
						|
                 value outside the permissible range then the agent should 
 | 
						|
                 adjust the value to the closest permissible value."
 | 
						|
              DEFVAL { 128 }
 | 
						|
              ::= { sFlowFsEntry 5 }
 | 
						|
 | 
						|
      --
 | 
						|
      -- Counter Polling Table
 | 
						|
      --
 | 
						|
      
 | 
						|
 | 
						|
      sFlowCpTable OBJECT-TYPE
 | 
						|
              SYNTAX      SEQUENCE OF SFlowCpEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "A table of the counter pollers within a device."
 | 
						|
              ::= { sFlowAgent 6 }
 | 
						|
 | 
						|
      sFlowCpEntry OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowCpEntry
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Attributes of a counter poller."
 | 
						|
              INDEX { sFlowCpDataSource, sFlowCpInstance }
 | 
						|
              ::= { sFlowCpTable 1 }
 | 
						|
 | 
						|
      SFlowCpEntry ::= SEQUENCE {
 | 
						|
              sFlowCpDataSource               SFlowDataSource,
 | 
						|
              sFlowCpInstance                 SFlowInstance,
 | 
						|
              sFlowCpReceiver                 SFlowReceiver,
 | 
						|
              sFlowCpInterval                 Integer32
 | 
						|
      }
 | 
						|
 | 
						|
      sFlowCpDataSource OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowDataSource
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Identifies the source of the data for the counter poller."
 | 
						|
              ::= { sFlowCpEntry 1 }
 | 
						|
 | 
						|
      sFlowCpInstance OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowInstance
 | 
						|
              MAX-ACCESS  not-accessible
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The sFlowInstance for this counter poller."
 | 
						|
              ::= { sFlowCpEntry 2 }
 | 
						|
 | 
						|
      sFlowCpReceiver OBJECT-TYPE
 | 
						|
              SYNTAX      SFlowReceiver
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The SFlowReciever associated with this counter poller."
 | 
						|
              DEFVAL { 0 }
 | 
						|
              ::= { sFlowCpEntry 3 }
 | 
						|
 | 
						|
      sFlowCpInterval OBJECT-TYPE
 | 
						|
              SYNTAX      Integer32
 | 
						|
              MAX-ACCESS  read-write
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "The maximum number of seconds between successive samples of the
 | 
						|
                 counters associated with this data source. A sampling interval 
 | 
						|
                 of 0 disables counter sampling.
 | 
						|
 | 
						|
                 The agent is permitted to have minimum and maximum allowable
 | 
						|
                 values for the counter polling interval. A minimum interval
 | 
						|
                 lets the agent designer set an upper bound on the overhead
 | 
						|
                 associated with polling, and a maximum interval may be the
 | 
						|
                 result of implementation restrictions (such as counter size).
 | 
						|
                 In addition not all values between the maximum and minimum may
 | 
						|
                 be realizable as the sampling interval (again because of
 | 
						|
                 implementation considerations).
 | 
						|
 | 
						|
                 When the sampling rate is set the agent is free to adjust the
 | 
						|
                 value so that it lies between the maximum and minimum values
 | 
						|
                 and has the closest achievable value.
 | 
						|
 | 
						|
                 When read, the agent must return the actual sampling interval
 | 
						|
                 it will be using (after the adjustments previously described).
 | 
						|
                 The sampling algorithm must converge so that over time the
 | 
						|
                 number of packets sampled approaches 1/Nth of the total number
 | 
						|
                 of packets in the monitored flows."
 | 
						|
              DEFVAL { 0 }
 | 
						|
              ::= { sFlowCpEntry 4 }
 | 
						|
 | 
						|
       --
 | 
						|
       -- Compliance Statements
 | 
						|
       --
 | 
						|
 | 
						|
      sFlowMIBConformance OBJECT IDENTIFIER ::= { sFlowMIB 2 }
 | 
						|
      sFlowMIBGroups      OBJECT IDENTIFIER ::= { sFlowMIBConformance 1 }
 | 
						|
      sFlowMIBCompliances OBJECT IDENTIFIER ::= { sFlowMIBConformance 2 }
 | 
						|
 | 
						|
      sFlowCompliance MODULE-COMPLIANCE
 | 
						|
              STATUS      current
 | 
						|
              DESCRIPTION
 | 
						|
                "Compliance statements for the sFlow Agent."
 | 
						|
 | 
						|
              MODULE -- this module
 | 
						|
                  MANDATORY-GROUPS { sFlowAgentGroup }
 | 
						|
 | 
						|
                  OBJECT     sFlowAgentAddressType
 | 
						|
                  SYNTAX     InetAddressType { ipv4(1) }
 | 
						|
                  DESCRIPTION
 | 
						|
                    "Agents need only support ipv4."
 | 
						|
 | 
						|
                  OBJECT sFlowRcvrAddressType
 | 
						|
                  SYNTAX InetAddressType { ipv4(1) }
 | 
						|
                  DESCRIPTION
 | 
						|
                    "Agents need only support ipv4."
 | 
						|
              
 | 
						|
              ::= { sFlowMIBCompliances 1 }
 | 
						|
 | 
						|
      sFlowAgentGroup OBJECT-GROUP
 | 
						|
              OBJECTS { sFlowVersion, sFlowAgentAddressType, sFlowAgentAddress,
 | 
						|
                        sFlowRcvrOwner, sFlowRcvrTimeout, 
 | 
						|
                        sFlowRcvrMaximumDatagramSize, sFlowRcvrAddressType, 
 | 
						|
                        sFlowRcvrAddress, sFlowRcvrPort, 
 | 
						|
                        sFlowRcvrDatagramVersion, sFlowFsReceiver, 
 | 
						|
                        sFlowFsPacketSamplingRate, sFlowFsMaximumHeaderSize, 
 | 
						|
                        sFlowCpReceiver, sFlowCpInterval }
 | 
						|
               STATUS current
 | 
						|
               DESCRIPTION
 | 
						|
                 "A collection of objects for managing the generation and
 | 
						|
                  transportation of sFlow data records."
 | 
						|
                ::= { sFlowMIBGroups 1 }
 | 
						|
 
 | 
						|
END
 | 
						|
 | 
						|
 |