-- File Name : PBI-MGSYSTEM-MIB
 | 
						|
-- Date      : Thu Sep 21 14:37:41 CST 2006
 | 
						|
-- Author    : AdventNet Agent Toolkit Java Edition - MIB Editor 6
 | 
						|
 | 
						|
 | 
						|
 | 
						|
PBI-MGSYSTEM-MIB	DEFINITIONS ::= BEGIN
 | 
						|
	IMPORTS
 | 
						|
		DisplayString, TruthValue, RowStatus
 | 
						|
			FROM SNMPv2-TC
 | 
						|
		DisplayString
 | 
						|
			FROM RFC1213-MIB
 | 
						|
		mg
 | 
						|
			FROM PBI-MAIN-MIB
 | 
						|
		MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises, IpAddress
 | 
						|
			FROM SNMPv2-SMI;
 | 
						|
 | 
						|
	mgSystem	MODULE-IDENTITY
 | 
						|
		LAST-UPDATED	"200609131023Z"
 | 
						|
		ORGANIZATION	"PBI"
 | 
						|
		CONTACT-INFO	"Tel:(010)82617178 
 | 
						|
									Fax:(010)82610263 
 | 
						|
									E-mail:mkt@pbi-china.com"
 | 
						|
		DESCRIPTION		"use this mib to manage the devise infomation"
 | 
						|
		REVISION		"200609131023Z"
 | 
						|
		DESCRIPTION		""
 | 
						|
		::=  {  mg  1  }
 | 
						|
 | 
						|
	basicInfo	OBJECT IDENTIFIER
 | 
						|
		::=  {  mgSystem  1  }
 | 
						|
 | 
						|
	unitName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString  ( SIZE ( 0 .. 255  ) ) 
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Digital headend device name"
 | 
						|
		::=  {  basicInfo  1  }
 | 
						|
 | 
						|
	serialNumber	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device serial number"
 | 
						|
		::=  {  basicInfo  2  }
 | 
						|
 | 
						|
	fpgaVersion	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"FPGA version number"
 | 
						|
		::=  {  basicInfo  3  }
 | 
						|
 | 
						|
	mcuVersion	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"MCU version number"
 | 
						|
		::=  {  basicInfo  4  }
 | 
						|
 | 
						|
	macAddress	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString  ( SIZE ( 0 .. 255  ) ) 
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"MAC address"
 | 
						|
		::=  {  basicInfo  5  }
 | 
						|
 | 
						|
	gateway	OBJECT-TYPE	
 | 
						|
		SYNTAX			IpAddress
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device gateway"
 | 
						|
		::=  {  basicInfo  6  }
 | 
						|
 | 
						|
	deviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			IpAddress
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Local device IP address "
 | 
						|
		::=  {  basicInfo  7  }
 | 
						|
 | 
						|
	subnetMask	OBJECT-TYPE	
 | 
						|
		SYNTAX			IpAddress
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device subnet mask"
 | 
						|
		::=  {  basicInfo  8  }
 | 
						|
 | 
						|
	trapIpAddress	OBJECT-TYPE
 | 
						|
		SYNTAX			IpAddress
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Trap IP address,can been set in device and send trap data to the appointed PC"
 | 
						|
		::=  {  basicInfo  9  }
 | 
						|
 | 
						|
	upgrade	OBJECT-TYPE	
 | 
						|
		SYNTAX			INTEGER     ( -2147483648 .. 2147483647  )
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"if it is enable,it will been permitted to upgrade by network,otherwise disable"
 | 
						|
		::=  {  basicInfo  10  }
 | 
						|
 | 
						|
	upgradeIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			IpAddress
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Upgrade IP address can been set by  manual in device, we can upgrade software version when new software be released"
 | 
						|
		::=  {  basicInfo  11  }
 | 
						|
 | 
						|
	default	OBJECT-TYPE	
 | 
						|
		SYNTAX			INTEGER  ( -2147483648 .. 2147483647  ) 
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device renew to factory setup"
 | 
						|
		::=  {  basicInfo  12  }
 | 
						|
 | 
						|
	deviceType	OBJECT-TYPE	
 | 
						|
		SYNTAX			INTEGER
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device type: 3000tm = 1111; 3000mux = 2222; 3000ec = 3333; 4000p = 4444; UDI4000Mx = 5555; reserve = 6666"
 | 
						|
		::=  {  basicInfo  13  }
 | 
						|
 | 
						|
	hardwareVersion	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device hardware version"
 | 
						|
		::=  {  basicInfo  14  }
 | 
						|
 | 
						|
	externdBoard	OBJECT-TYPE	
 | 
						|
		SYNTAX			TruthValue
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Description"
 | 
						|
		::=  {  basicInfo  15  }
 | 
						|
 | 
						|
	trapDeviceOffTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapDeviceOffEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  16 }
 | 
						|
     
 | 
						|
  trapDeviceOffEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapDeviceOffEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  deviceOffDeviceName  }
 | 
						|
		::=  { trapDeviceOffTable 1 }
 | 
						|
           
 | 
						|
	TrapDeviceOffEntry  ::=  
 | 
						|
		SEQUENCE {
 | 
						|
			deviceOffDeviceName    DisplayString,
 | 
						|
			deviceOffDeviceIP      DisplayString, 
 | 
						|
			deviceOffReserve       DisplayString,
 | 
						|
			deviceOffLevel         DisplayString,
 | 
						|
			deviceOffTriggerTime   DisplayString,
 | 
						|
			deviceOffDescription   DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	deviceOffDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device name"
 | 
						|
		::=  {  trapDeviceOffEntry  1  }
 | 
						|
 | 
						|
	deviceOffDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapDeviceOffEntry  2  } 
 | 
						|
		    
 | 
						|
	deviceOffReserve	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapDeviceOffEntry  3  } 
 | 
						|
		    		  		    
 | 
						|
	deviceOffLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Alarm level: level 2"
 | 
						|
		::=  {  trapDeviceOffEntry  4  }
 | 
						|
		
 | 
						|
	deviceOffTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapDeviceOffEntry  5  }
 | 
						|
		
 | 
						|
	deviceOffDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Device Off"
 | 
						|
		::=  {  trapDeviceOffEntry  6  }
 | 
						|
 | 
						|
 	trapDeviceOnTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapDeviceOnEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  17 }
 | 
						|
     
 | 
						|
  trapDeviceOnEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapDeviceOnEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  deviceOnDeviceName  }
 | 
						|
		::=  { trapDeviceOnTable 1 }
 | 
						|
           
 | 
						|
	TrapDeviceOnEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			deviceOnDeviceName    DisplayString,
 | 
						|
			deviceOnDeviceIP      DisplayString,
 | 
						|
			deviceOnReserve       DisplayString,
 | 
						|
			deviceOnLevel         DisplayString,
 | 
						|
			deviceOnTriggerTime   DisplayString,
 | 
						|
			deviceOnDescription   DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	deviceOnDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device name"
 | 
						|
		::=  {  trapDeviceOnEntry  1  }
 | 
						|
 | 
						|
	deviceOnDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapDeviceOnEntry  2  }
 | 
						|
 | 
						|
  deviceOnReserve	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapDeviceOnEntry  3  }
 | 
						|
		
 | 
						|
	deviceOnLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Alarm leve: level 2"
 | 
						|
		::=  {  trapDeviceOnEntry  4  }
 | 
						|
 | 
						|
	deviceOnTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapDeviceOnEntry  5  }
 | 
						|
		
 | 
						|
	deviceOnDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Description information "
 | 
						|
		::=  {  trapDeviceOnEntry  6  }
 | 
						|
 | 
						|
 	trapFanFailedTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapFanFailedEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  18 }
 | 
						|
     
 | 
						|
  trapFanFailedEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapFanFailedEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  fanFailedDeviceName  }
 | 
						|
		::=  { trapFanFailedTable 1 }     
 | 
						|
           
 | 
						|
	TrapFanFailedEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			fanFailedDeviceName    DisplayString,
 | 
						|
			fanFailedDeviceIP      DisplayString,
 | 
						|
			fanFailedReserve       DisplayString,
 | 
						|
    	fanFailedLevel         DisplayString,
 | 
						|
			fanFailedTriggerTime   DisplayString,
 | 
						|
			fanFailedDescription   DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	fanFailedDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device name"
 | 
						|
		::=  {  trapFanFailedEntry  1  }
 | 
						|
 | 
						|
	fanFailedDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapFanFailedEntry  2  }
 | 
						|
 | 
						|
  fanFailedReserve	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device IP address"
 | 
						|
		::=  {  trapFanFailedEntry  3  }
 | 
						|
		
 | 
						|
	fanFailedLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Alarm level: level 1"
 | 
						|
		::=  {  trapFanFailedEntry  4  }
 | 
						|
		
 | 
						|
	fanFailedTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapFanFailedEntry  5  }
 | 
						|
		
 | 
						|
	fanFailedDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Description information "
 | 
						|
		::=  {  trapFanFailedEntry  6  }
 | 
						|
      
 | 
						|
  trapSignalOffTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapSignalOffEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  19 }
 | 
						|
 | 
						|
  trapSignalOffEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapSignalOffEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  signalOffDeviceName  }
 | 
						|
		::=  { trapSignalOffTable 1 }  
 | 
						|
           
 | 
						|
	TrapSignalOffEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			signalOffDeviceName    DisplayString,
 | 
						|
			signalOffDeviceIP      DisplayString, 
 | 
						|
			signalOffChannel			 DisplayString,
 | 
						|
			signalOffLevel         DisplayString,
 | 
						|
			signalOffTriggerTime   DisplayString,
 | 
						|
			signalOffDescription   DisplayString,
 | 
						|
			signalOffSlot	       	 DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	signalOffDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapSignalOffEntry  1  }
 | 
						|
 | 
						|
	signalOffDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapSignalOffEntry  2  }
 | 
						|
		
 | 
						|
	signalOffChannel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" the channel for signal off trap "
 | 
						|
		::=  {  trapSignalOffEntry  3  }
 | 
						|
				
 | 
						|
	signalOffLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Alarm level: level 3 "
 | 
						|
		::=  {  trapSignalOffEntry  4  }
 | 
						|
		
 | 
						|
	signalOffTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Event trigger time "
 | 
						|
		::=  {  trapSignalOffEntry  5  }
 | 
						|
		
 | 
						|
	signalOffDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Description information "
 | 
						|
		::=  {  trapSignalOffEntry  6  }
 | 
						|
	
 | 
						|
	signalOffSlot	OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Slot number"
 | 
						|
		::=  {  trapSignalOffEntry  7  }
 | 
						|
	
 | 
						|
  trapSignalOnTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapSignalOnEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  20 }
 | 
						|
     
 | 
						|
  trapSignalOnEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapSignalOnEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  signalOnDeviceName  }
 | 
						|
		::=  { trapSignalOnTable 1 }   
 | 
						|
           
 | 
						|
	TrapSignalOnEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			signalOnDeviceName    DisplayString,
 | 
						|
			signalOnDeviceIP      DisplayString, 
 | 
						|
			signalOnChannel				DisplayString, 
 | 
						|
			signalOnLevel         DisplayString,
 | 
						|
			signalOnTriggerTime   DisplayString,
 | 
						|
			signalOnDescription   DisplayString,
 | 
						|
			signalOnSlot					DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	signalOnDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"device name"
 | 
						|
		::=  {  trapSignalOnEntry  1  }
 | 
						|
 | 
						|
	signalOnDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapSignalOnEntry  2  }
 | 
						|
 | 
						|
	signalOnChannel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" the channel for signal on trap "
 | 
						|
		::=  {  trapSignalOnEntry  3  }
 | 
						|
		
 | 
						|
	signalOnLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Alarm level: level 3 "
 | 
						|
		::=  {  trapSignalOnEntry  4  }
 | 
						|
		
 | 
						|
	signalOnTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapSignalOnEntry  5  }
 | 
						|
		
 | 
						|
	signalOnDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Description information "
 | 
						|
		::=  {  trapSignalOnEntry  6  }
 | 
						|
		 
 | 
						|
	signalOnSlot	OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Slot number "
 | 
						|
		::=  {  trapSignalOnEntry  7  }	
 | 
						|
		     
 | 
						|
	trapSignalChangeTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapSignalChangeEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  21 }
 | 
						|
		
 | 
						|
  trapSignalChangeEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapSignalChangeEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  signalChangeDeviceName  }
 | 
						|
		::=  { trapSignalChangeTable 1 }     
 | 
						|
           
 | 
						|
	TrapSignalChangeEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			signalChangeDeviceName     DisplayString,
 | 
						|
			signalChangeDeviceIP       DisplayString, 
 | 
						|
			signalChangeChannel				 DisplayString,
 | 
						|
			signalChangeLevel          DisplayString,
 | 
						|
			signalChangeTriggerTime    DisplayString,
 | 
						|
			signalChangeDescription    DisplayString,
 | 
						|
			signalChangeSlot	         DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	signalChangeDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapSignalChangeEntry  1  }
 | 
						|
 | 
						|
	signalChangeDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapSignalChangeEntry  2  }
 | 
						|
 | 
						|
	signalChangeChannel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" the channel for signal change trap "
 | 
						|
		::=  {  trapSignalChangeEntry  3  }
 | 
						|
		
 | 
						|
	signalChangeLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Alarm level: level 3 "
 | 
						|
		::=  {  trapSignalChangeEntry  4  }
 | 
						|
		
 | 
						|
	signalChangeTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Event trigger time "
 | 
						|
		::=  {  trapSignalChangeEntry  5  }
 | 
						|
		
 | 
						|
	signalChangeDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Description information "
 | 
						|
		::=  {  trapSignalChangeEntry  6  }  
 | 
						|
		
 | 
						|
	signalChangeSlot	OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Slot number"
 | 
						|
		::=  {  trapSignalChangeEntry  7  } 		                                    
 | 
						|
		                                
 | 
						|
  trapTSOverflowTable	OBJECT-TYPE	
 | 
						|
		SYNTAX SEQUENCE  OF  TrapTSOverflowEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  { basicInfo  22 }
 | 
						|
     
 | 
						|
  trapTSOverflowEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapTSOverflowEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  tsOverflowDeviceName  }
 | 
						|
		::=  { trapTSOverflowTable 1 }     
 | 
						|
           
 | 
						|
	TrapTSOverflowEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			tsOverflowDeviceName    DisplayString,
 | 
						|
			tsOverflowDeviceIP      DisplayString, 
 | 
						|
			tsOverflowChannel       DisplayString,
 | 
						|
			tsOverflowLevel         DisplayString,
 | 
						|
			tsOverflowTriggerTime   DisplayString,
 | 
						|
			tsOverflowDescription   DisplayString,
 | 
						|
			tsOverflowSlot	        DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	tsOverflowDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapTSOverflowEntry  1  }
 | 
						|
 | 
						|
	tsOverflowDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapTSOverflowEntry  2  }
 | 
						|
		  
 | 
						|
	tsOverflowChannel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" the channel for TS overflow trap "
 | 
						|
		::=  {  trapTSOverflowEntry  3  } 
 | 
						|
  
 | 
						|
	tsOverflowLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Alarm level: level 1 "
 | 
						|
		::=  {  trapTSOverflowEntry  4  }
 | 
						|
		
 | 
						|
	tsOverflowTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Event trigger time "
 | 
						|
		::=  {  trapTSOverflowEntry  5  }
 | 
						|
		
 | 
						|
	tsOverflowDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Description information "
 | 
						|
		::=  {  trapTSOverflowEntry  6  }
 | 
						|
	
 | 
						|
	tsOverflowSlot	 OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Slot number"
 | 
						|
		::=  {  trapTSOverflowEntry  7  }
 | 
						|
		
 | 
						|
  rebootCommand	OBJECT-TYPE
 | 
						|
		SYNTAX			INTEGER
 | 
						|
		MAX-ACCESS		read-write
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"send reboot unit command: send 1 to Agent for reboot"
 | 
						|
		::=  {  basicInfo  23  }  
 | 
						|
		
 | 
						|
  trapTSIDErrorTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapTSIDErrorEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  {  basicInfo  24  }
 | 
						|
		
 | 
						|
  trapTSIDErrorEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapTSIDErrorEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  tsIDErrorDeviceName  }
 | 
						|
		::=  { trapTSIDErrorTable 1 } 
 | 
						|
           
 | 
						|
	TrapTSIDErrorEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			tsIDErrorDeviceName    DisplayString,
 | 
						|
			tsIDErrorDeviceIP      DisplayString, 
 | 
						|
			tsIDErrorTsID     		 DisplayString,
 | 
						|
			tsIDErrorLevel         DisplayString,
 | 
						|
			tsIDErrorTriggerTime   DisplayString,
 | 
						|
			tsIDErrorDescription   DisplayString,
 | 
						|
			tsIDErrorSlot	         DisplayString
 | 
						|
  }
 | 
						|
 | 
						|
	tsIDErrorDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapTSIDErrorEntry  1  }
 | 
						|
 | 
						|
	tsIDErrorDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapTSIDErrorEntry  2  }
 | 
						|
		  
 | 
						|
 	tsIDErrorTsID	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" wrong ts id "
 | 
						|
		::=  {  trapTSIDErrorEntry  3  } 
 | 
						|
  
 | 
						|
	tsIDErrorLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Alarm level: level 1"
 | 
						|
		::=  {  trapTSIDErrorEntry  4  }
 | 
						|
		
 | 
						|
	tsIDErrorTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapTSIDErrorEntry  5  }
 | 
						|
 | 
						|
	tsIDErrorDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Description information "
 | 
						|
		::=  {  trapTSIDErrorEntry  6  }
 | 
						|
	
 | 
						|
	tsIDErrorSlot	OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Slot number"
 | 
						|
		::=  {  trapTSIDErrorEntry  7  }
 | 
						|
                                         
 | 
						|
 trapTSIDRightTable	OBJECT-TYPE
 | 
						|
		SYNTAX		SEQUENCE  OF  TrapTSIDRightEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Description"
 | 
						|
		::=  {  basicInfo  25  }
 | 
						|
	
 | 
						|
	trapTSIDRightEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapTSIDRightEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	"Row Description"
 | 
						|
		INDEX		{  tsIDRightDeviceName  }
 | 
						|
		::=  { trapTSIDRightTable 1 }     
 | 
						|
           
 | 
						|
	TrapTSIDRightEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			tsIDRightDeviceName    DisplayString,
 | 
						|
			tsIDRightDeviceIP      DisplayString, 
 | 
						|
			tsIDRightTSID     		 DisplayString,
 | 
						|
			tsIDRightLevel         DisplayString,
 | 
						|
			tsIDRightTriggerTime   DisplayString,
 | 
						|
			tsIDRightDescription   DisplayString,
 | 
						|
			tsIDRightSlot	       	 DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	tsIDRightDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapTSIDRightEntry  1  }
 | 
						|
 | 
						|
	tsIDRightDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address "
 | 
						|
		::=  {  trapTSIDRightEntry  2  }
 | 
						|
		  
 | 
						|
 	tsIDRightTSID	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" right ts id "
 | 
						|
		::=  {  trapTSIDRightEntry  3  } 
 | 
						|
  
 | 
						|
	tsIDRightLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Alarm level: level 1 "
 | 
						|
		::=  {  trapTSIDRightEntry  4  }
 | 
						|
		
 | 
						|
	tsIDRightTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Event trigger time "
 | 
						|
		::=  {  trapTSIDRightEntry  5  }
 | 
						|
		
 | 
						|
	tsIDRightDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Description information "
 | 
						|
		::=  {  trapTSIDRightEntry  6  }
 | 
						|
	
 | 
						|
	tsIDRightSlot	       OBJECT-TYPE
 | 
						|
	   SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" Slot number "
 | 
						|
		::=  {  trapTSIDRightEntry  7  }  
 | 
						|
	
 | 
						|
	trapTSBitRateNormalTable	OBJECT-TYPE	
 | 
						|
		SYNTAX SEQUENCE  OF  TrapTSBitRateNormalEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	" Description "
 | 
						|
		::=  { basicInfo  26 }
 | 
						|
     
 | 
						|
  trapTSBitRateNormalEntry	OBJECT-TYPE
 | 
						|
		SYNTAX		TrapTSBitRateNormalEntry
 | 
						|
		MAX-ACCESS	not-accessible
 | 
						|
		STATUS		current
 | 
						|
		DESCRIPTION	" Row Description "
 | 
						|
		INDEX		{  tsBitRateNormalDeviceName  }
 | 
						|
		::=  { trapTSBitRateNormalTable 1 }     
 | 
						|
           
 | 
						|
	TrapTSBitRateNormalEntry  ::=
 | 
						|
		SEQUENCE {
 | 
						|
			tsBitRateNormalDeviceName    DisplayString,
 | 
						|
			tsBitRateNormalDeviceIP      DisplayString, 
 | 
						|
			tsBitRateNormalChannel       DisplayString,
 | 
						|
			tsBitRateNormalLevel         DisplayString,
 | 
						|
			tsBitRateNormalTriggerTime   DisplayString,
 | 
						|
			tsBitRateNormalDescription   DisplayString,
 | 
						|
			tsBitRateNormalSlot	         DisplayString
 | 
						|
		}
 | 
						|
 | 
						|
	tsBitRateNormalDeviceName	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device name "
 | 
						|
		::=  {  trapTSBitRateNormalEntry  1  }
 | 
						|
 | 
						|
	tsBitRateNormalDeviceIP	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" device IP address"
 | 
						|
		::=  {  trapTSBitRateNormalEntry  2  }
 | 
						|
		  
 | 
						|
	tsBitRateNormalChannel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		" the channel for TS bit rate normal trap "
 | 
						|
		::=  {  trapTSBitRateNormalEntry  3  } 
 | 
						|
  
 | 
						|
	tsBitRateNormalLevel	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Alarm level: level 1"
 | 
						|
		::=  {  trapTSBitRateNormalEntry  4  }
 | 
						|
		
 | 
						|
	tsBitRateNormalTriggerTime	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Event trigger time"
 | 
						|
		::=  {  trapTSBitRateNormalEntry  5  }
 | 
						|
		
 | 
						|
	tsBitRateNormalDescription	OBJECT-TYPE	
 | 
						|
		SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Description information "
 | 
						|
		::=  {  trapTSBitRateNormalEntry  6  }
 | 
						|
		
 | 
						|
	tsBitRateNormalSlot  OBJECT-TYPE
 | 
						|
	  SYNTAX			DisplayString
 | 
						|
		MAX-ACCESS		read-only
 | 
						|
		STATUS			current
 | 
						|
		DESCRIPTION		"Slot number"
 | 
						|
		::=  {  trapTSBitRateNormalEntry  7  }
 | 
						|
		
 | 
						|
	virtualGroupInfo	OBJECT-TYPE	
 | 
						|
		SYNTAX			 DisplayString
 | 
						|
		MAX-ACCESS	 read-write
 | 
						|
		STATUS			 current
 | 
						|
		DESCRIPTION  "virtual group info"
 | 
						|
		::=  {  basicInfo  27  }
 | 
						|
		
 | 
						|
  moduleNumber	OBJECT-TYPE	
 | 
						|
		SYNTAX			 INTEGER
 | 
						|
		MAX-ACCESS	 read-only
 | 
						|
		STATUS			 current
 | 
						|
		DESCRIPTION  "the module number"
 | 
						|
		::=  {  basicInfo  28  }
 | 
						|
		
 | 
						|
	chestTemp	OBJECT-TYPE	
 | 
						|
		SYNTAX			 INTEGER
 | 
						|
		MAX-ACCESS	 read-only
 | 
						|
		STATUS			 current
 | 
						|
		DESCRIPTION  "the chest Temperature"
 | 
						|
		::=  {  basicInfo  29  }
 | 
						|
		
 | 
						|
	lcdSwitch	OBJECT-TYPE
 | 
						|
		SYNTAX			 INTEGER {
 | 
						|
			alwaysOn(0),
 | 
						|
			time(1)
 | 
						|
		}
 | 
						|
		MAX-ACCESS	 read-write
 | 
						|
		STATUS			 current
 | 
						|
		DESCRIPTION  " control LCD background "
 | 
						|
		::=  {  basicInfo  35  }
 | 
						|
	
 | 
						|
END
 |