1071 lines
		
	
	
		
			33 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			1071 lines
		
	
	
		
			33 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
RADLAN-rndApplications DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
-- Title:      RADLAN Application Private Extension
 | 
						|
-- Version:    7.37.00.00
 | 
						|
-- Date:       17 May 2004
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    rnd                                                     FROM RADLAN-MIB
 | 
						|
    InterfaceIndexOrZero, InterfaceIndex, ifIndex           FROM IF-MIB
 | 
						|
    DisplayString                                           FROM SNMPv2-TC-v1
 | 
						|
    Unsigned32, Counter32, IpAddress,
 | 
						|
    MODULE-IDENTITY, OBJECT-TYPE                            FROM SNMPv2-SMI
 | 
						|
    RowStatus, TruthValue,
 | 
						|
    TEXTUAL-CONVENTION                                      FROM SNMPv2-TC;
 | 
						|
 | 
						|
rndApplications  MODULE-IDENTITY
 | 
						|
                 LAST-UPDATED "200406010000Z"
 | 
						|
                 ORGANIZATION "Radlan Computer Communications Ltd."
 | 
						|
                 CONTACT-INFO
 | 
						|
                      "radlan.com"
 | 
						|
                 DESCRIPTION
 | 
						|
                      "The private MIB module definition for RND applications MIB."
 | 
						|
                 REVISION "200406010000Z"
 | 
						|
                 DESCRIPTION
 | 
						|
                      "Initial version of this MIB."
 | 
						|
                 ::= { rnd 35 }
 | 
						|
 | 
						|
 | 
						|
-- Obsolete
 | 
						|
-- rsServerDispatcher  OBJECT IDENTIFIER ::= { rndApplications 1}
 | 
						|
 | 
						|
-- rndMidLevelManagement group contains variables which direct the mid-level
 | 
						|
-- management stations how to monitor and manage their domains.
 | 
						|
 | 
						|
rndMidLevelManagement  OBJECT IDENTIFIER ::= { rndApplications 2} -- NEW Group
 | 
						|
 | 
						|
rndAlarmOptions  OBJECT IDENTIFIER ::= { rndMidLevelManagement 2}
 | 
						|
 | 
						|
rndAlarmEnabling OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        enabled(1),
 | 
						|
        disabled(2)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Indicates whether alarms should be issued to the high-level
 | 
						|
         NMS "
 | 
						|
     ::=  { rndAlarmOptions 1 }
 | 
						|
 | 
						|
rndAlarmInterval OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Indicates the minimal period of time which must pass after issuing
 | 
						|
         an alarm before issuing the same alarm again."
 | 
						|
     ::=  { rndAlarmOptions 2 }
 | 
						|
 | 
						|
rndMonitoredElementsTable  OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RndMonitoredElementEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The table of monitored elements of the network"
 | 
						|
    ::= {rndMidLevelManagement 3}
 | 
						|
 | 
						|
rndMonitoredElementEntry  OBJECT-TYPE
 | 
						|
   SYNTAX RndMonitoredElementEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " The row definition for this table."
 | 
						|
   INDEX { rndMonitoredElementAddress }
 | 
						|
    ::= {rndMonitoredElementsTable 1}
 | 
						|
 | 
						|
RndMonitoredElementEntry ::= SEQUENCE {
 | 
						|
 | 
						|
rndMonitoredElementAddress    IpAddress,
 | 
						|
rndMonitoredElementCommunity  DisplayString(SIZE(1..20)),
 | 
						|
rndMonitoredElementLabel      DisplayString(SIZE(1..20)),
 | 
						|
rndDefaultPollingInterval     INTEGER,
 | 
						|
rndDefaultLogFile             DisplayString,
 | 
						|
rndMonitoredElementStatus     RowStatus
 | 
						|
}
 | 
						|
rndMonitoredElementAddress OBJECT-TYPE
 | 
						|
   SYNTAX IpAddress
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The IP address of the monitored element"
 | 
						|
     ::=  {rndMonitoredElementEntry  1 }
 | 
						|
 | 
						|
rndMonitoredElementCommunity OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(1..20))
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The community of the monitored element"
 | 
						|
     ::=  {rndMonitoredElementEntry 2  }
 | 
						|
 | 
						|
rndMonitoredElementLabel OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(1..20))
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The label assigned by the network manager to the monitored element"
 | 
						|
     ::=  {rndMonitoredElementEntry 3}
 | 
						|
 | 
						|
rndDefaultPollingInterval OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The default period of time between two consecutive pollings of the
 | 
						|
     monitored element for the value of an object instance. If no other polling
 | 
						|
     interval is specifically assigned to the monitored object instance, this
 | 
						|
     one will be used"
 | 
						|
     ::=  {rndMonitoredElementEntry 4}
 | 
						|
 | 
						|
rndDefaultLogFile OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The default file path of the log-file which will contain the polling
 | 
						|
     results for the monitored element. If no other file path is specifically
 | 
						|
     assigned to the monitored object instance, this log-file will be used."
 | 
						|
 | 
						|
     ::=  {rndMonitoredElementEntry  5}
 | 
						|
 | 
						|
rndMonitoredElementStatus OBJECT-TYPE
 | 
						|
   SYNTAX RowStatus
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         "It is used to manage the monitored elements table and indicates
 | 
						|
          the current monitoring status of an element."
 | 
						|
     ::=  {rndMonitoredElementEntry  6}
 | 
						|
 | 
						|
rndMonitoringTable  OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RndMonitoringEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The table of monitored object instances. Each monitored object instance
 | 
						|
     belongs to a monitored element previously entered in the
 | 
						|
     rndMonitoredElementsTable. "
 | 
						|
    ::= {rndMidLevelManagement 4}
 | 
						|
 | 
						|
rndMonitoringEntry OBJECT-TYPE
 | 
						|
   SYNTAX RndMonitoringEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " The row definition for this table."
 | 
						|
   INDEX { rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel }
 | 
						|
    ::= {rndMonitoringTable 1}
 | 
						|
 | 
						|
RndMonitoringEntry ::= SEQUENCE {
 | 
						|
 | 
						|
rndMonitoredElement             DisplayString(SIZE(1..20)),
 | 
						|
rndMonitoredObjectInstanceLabel DisplayString,
 | 
						|
rndMonitoredObjectName          DisplayString,
 | 
						|
rndMonitoredObjectIdentifier    OBJECT IDENTIFIER,
 | 
						|
rndMonitoredObjectInstance      OBJECT IDENTIFIER,
 | 
						|
rndMonitoredObjectSyntax        INTEGER,
 | 
						|
rndMonitoringInterval           INTEGER,
 | 
						|
rndAlarmMaxTreshold             INTEGER,
 | 
						|
rndAlarmMinTreshold             INTEGER,
 | 
						|
rndMonitoringLogfile            DisplayString,
 | 
						|
rndMonitoringEntryStatus        RowStatus,
 | 
						|
rndMonitoredIntegerInstance     INTEGER
 | 
						|
}
 | 
						|
 | 
						|
rndMonitoredElement OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(1..20))
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "A label assigned by the network manager to a monitored element to
 | 
						|
     which this monitored object instance belongs. This label must have
 | 
						|
     been previously entered in an instance of rndMonitoredElementLabel"
 | 
						|
    ::=  {rndMonitoringEntry  1}
 | 
						|
 | 
						|
rndMonitoredObjectInstanceLabel OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(1..20))
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The label assigned by the network manager to the monitored object instance"
 | 
						|
    ::=  {rndMonitoringEntry  2}
 | 
						|
 | 
						|
rndMonitoredObjectName OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(0..20))
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The symbolic object type name of the object to which the monitored object
 | 
						|
     instance belongs (as it appears the MIB module definition). In case of
 | 
						|
     ambiguity the <MIB module name> : <object type name> format should be used.
 | 
						|
     An instance of rndMonitoredObjectName need not be assigned any value, if
 | 
						|
     the corresponding instance of rndMonitoredObjectIdentifier is assigned a
 | 
						|
     value, since any one of these, together with the object instance
 | 
						|
     identifier, suffices to unambigously identify the monitored object
 | 
						|
     instance."
 | 
						|
 | 
						|
    ::=  {rndMonitoringEntry  3}
 | 
						|
 | 
						|
rndMonitoredObjectIdentifier OBJECT-TYPE
 | 
						|
   SYNTAX OBJECT IDENTIFIER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The object identifier of the object to which the monitored object
 | 
						|
     instance belongs.
 | 
						|
     An instance of rndMonitoredObjectIdentifier need not be assigned any value, if
 | 
						|
     the corresponding instance of rndMonitoredObjectName is assigned a value,
 | 
						|
     since any one of these, together with the object instance identifier,
 | 
						|
     suffices to unambigously identify the monitored object instance."
 | 
						|
 | 
						|
    ::=  {rndMonitoringEntry  4}
 | 
						|
 | 
						|
rndMonitoredObjectInstance OBJECT-TYPE
 | 
						|
   SYNTAX OBJECT IDENTIFIER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
        "The instance identifier (key) of the monitored object instance."
 | 
						|
    ::=  {rndMonitoringEntry  5}
 | 
						|
 | 
						|
rndMonitoredObjectSyntax OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER {
 | 
						|
       integer(1),
 | 
						|
       octet-string(2),
 | 
						|
       ip-address(3),
 | 
						|
       object-identifier(4)
 | 
						|
     }
 | 
						|
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The syntax of the monitored object instance (i.e., the syntax of the object
 | 
						|
     type of the object to which the monitored instance belongs).
 | 
						|
     Need not be assigned any value if the corresponding instance of
 | 
						|
     rndMonitoredObjectName has been assigned a value"
 | 
						|
    ::=  {rndMonitoringEntry  6}
 | 
						|
 | 
						|
rndMonitoringInterval OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The period of time between two consecutive retrievals of the monitored
 | 
						|
     object instance's value."
 | 
						|
    ::=  {rndMonitoringEntry  7}
 | 
						|
 | 
						|
 | 
						|
rndAlarmMaxTreshold OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The value of the monitored object instance, the exceeding of which
 | 
						|
     will cause the generation of an alarm to the high-level management
 | 
						|
     station."
 | 
						|
    ::=  {rndMonitoringEntry 8}
 | 
						|
 | 
						|
rndAlarmMinTreshold OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "If the value of the monitored object instance falls below the value
 | 
						|
     assigned to rndAlarmMinTreshold, an alarm to the high-level management
 | 
						|
     station will be issued."
 | 
						|
    ::=  {rndMonitoringEntry  9}
 | 
						|
 | 
						|
 | 
						|
rndMonitoringLogfile OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The entire path of the file in which the results of the monitoring
 | 
						|
     of this object instance should be recorded."
 | 
						|
    ::=  {rndMonitoringEntry  10}
 | 
						|
 | 
						|
rndMonitoringEntryStatus OBJECT-TYPE
 | 
						|
   SYNTAX RowStatus
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         "It is used to manage the monitored object instances table and
 | 
						|
          indicates the current monitoring status of an object instance."
 | 
						|
    ::=  {rndMonitoringEntry  11}
 | 
						|
 | 
						|
rndMonitoredIntegerInstance OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         ""
 | 
						|
    ::=  {rndMonitoringEntry  12}
 | 
						|
 | 
						|
rndMibFilesTable  OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RndMibFileEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The table of monitored object instances. Each monitored object instance
 | 
						|
     belongs to a monitored element previously entered in the
 | 
						|
     rndMonitoredElementsTable. "
 | 
						|
    ::= {rndMidLevelManagement 5}
 | 
						|
 | 
						|
rndMibFileEntry OBJECT-TYPE
 | 
						|
   SYNTAX RndMibFileEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " The row definition for this table."
 | 
						|
   INDEX { rndMibFileIndex }
 | 
						|
    ::= {rndMibFilesTable 1}
 | 
						|
 | 
						|
RndMibFileEntry ::= SEQUENCE {
 | 
						|
 | 
						|
rndMibFileIndex                 INTEGER,
 | 
						|
rndMibFilePath                  DisplayString,
 | 
						|
rndMibFileRefresh               INTEGER,
 | 
						|
rndMibFileEntryStatus           RowStatus
 | 
						|
}
 | 
						|
rndMibFileIndex OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The number of the MIB file in the list MIB files supported by the
 | 
						|
     Mid-Level management station. The order of the MIB files in this
 | 
						|
     list must reflect the the IMPORT relation between the MIBS contained
 | 
						|
     in the MIB files, i.e., if MIB A IMPORTS FROM MIB B, the file containing
 | 
						|
     MIB A must have a lesser index in this table than the file containing
 | 
						|
     MIB B."
 | 
						|
    ::=  {rndMibFileEntry  1}
 | 
						|
 | 
						|
 | 
						|
rndMibFilePath OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The path of the MIB file in the MIB file server."
 | 
						|
    ::=  {rndMibFileEntry  2}
 | 
						|
 | 
						|
rndMibFileRefresh OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER {
 | 
						|
      no(1),
 | 
						|
      yes(2)
 | 
						|
   }
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "Indicates if the file should be fetched after setting this entry from the
 | 
						|
     MIB file server."
 | 
						|
    ::=  {rndMibFileEntry  3}
 | 
						|
 | 
						|
rndMibFileEntryStatus OBJECT-TYPE
 | 
						|
   SYNTAX RowStatus
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         "It is used to manage the MIB files table."
 | 
						|
    ::=  {rndMibFileEntry  4}
 | 
						|
 | 
						|
rndHardwareConfiguration OBJECT-TYPE
 | 
						|
    SYNTAX TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Indicates whether the current SET SNMP PDU contains hardware
 | 
						|
         configuration (i.e., normally read-only variables). SET of such
 | 
						|
         variables in the Mid-level management station will be allowed only
 | 
						|
         if this variable is included in the SNMP PDU and its value is true.
 | 
						|
         Its value as returned in  a GET SNMP PDU will always be false."
 | 
						|
    ::= {rndMidLevelManagement 6}
 | 
						|
 | 
						|
rndEraseSimulatedConfiguration OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        eraseSimulatedConfiguration(1),
 | 
						|
        simulatedConfigurationPresent(2),
 | 
						|
        simulatedConfigurationErased(3)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "eraseSimulatedConfiguration instructs the MLNMS to erase all the
 | 
						|
         simulated configuration from its configuration data-base (CDB). This
 | 
						|
         the only accepted value for SNMP SET statements and will never be
 | 
						|
         returned in SNMP GET statements.
 | 
						|
         simulatedConfigurationPresent indicates that the MLNMS currently has
 | 
						|
         a simulated configuration.
 | 
						|
         simulatedConfigurationErased indicates that the MLNMS currently has
 | 
						|
         no simulated configuration."
 | 
						|
    ::= {rndMidLevelManagement 7}
 | 
						|
 | 
						|
rndDeleteValuesTable  OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RndDeleteValuesEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This table indicates which MIB variables are row status fields which
 | 
						|
     control the status of the entry to which they belong. This table also
 | 
						|
     indicates which (integer!) value of these MIB variables will cause, if
 | 
						|
     present in a SNMP SET PDU, the deletion of the conceptual row instance
 | 
						|
     to which the SET MIB variable instance belongs."
 | 
						|
    ::= {rndMidLevelManagement 8}
 | 
						|
 | 
						|
rndDeleteValuesEntry  OBJECT-TYPE
 | 
						|
   SYNTAX RndDeleteValuesEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " The row definition for the rndDeleteValuesTable table."
 | 
						|
   INDEX { IMPLIED rndRowStatusVariableName }
 | 
						|
    ::= {rndDeleteValuesTable 1}
 | 
						|
 | 
						|
RndDeleteValuesEntry ::= SEQUENCE {
 | 
						|
 | 
						|
rndRowStatusVariableName    DisplayString,
 | 
						|
rndRowStatusObjectId        OBJECT IDENTIFIER,
 | 
						|
rndRowDeleteValue           INTEGER,
 | 
						|
rndDeleteValueEntryStatus   RowStatus
 | 
						|
}
 | 
						|
 | 
						|
rndRowStatusVariableName OBJECT-TYPE
 | 
						|
   SYNTAX DisplayString(SIZE(1..80))
 | 
						|
--   MAX-ACCESS         read-only
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The name of the row status field. This name may not necessarily be any
 | 
						|
     name which is present in the MIBs loaded into the MLNMS station."
 | 
						|
 | 
						|
     ::=  {rndDeleteValuesEntry 1}
 | 
						|
 | 
						|
rndRowStatusObjectId OBJECT-TYPE
 | 
						|
   SYNTAX OBJECT IDENTIFIER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The object id of the row status field. If the rndRowStatusVariableName is
 | 
						|
     a name present in the MIBs loaded into the MLNMS, this MIB
 | 
						|
     variable is not required, but if given, it must match the object id known
 | 
						|
     to the MLNMS.
 | 
						|
     The variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId
 | 
						|
     must be a read-write MIB variable of type INTEGER which belongs to an
 | 
						|
     entry (i.e, is a child of a MIB variable of type SEQUENCE)."
 | 
						|
 | 
						|
     ::=  {rndDeleteValuesEntry 2}
 | 
						|
 | 
						|
rndRowDeleteValue OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The value of the variable identified by rndRowStatusVariableName and/or
 | 
						|
     rndRowStatusObjectId, which, if present in a SNMP SET PDU, will cause
 | 
						|
     the deletion of the conceptual row instance which the SET MIB variable
 | 
						|
     instance belongs."
 | 
						|
     ::=  {rndDeleteValuesEntry 3}
 | 
						|
 | 
						|
rndDeleteValueEntryStatus  OBJECT-TYPE
 | 
						|
   SYNTAX  RowStatus
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         "It is used to delete an entry from this table."
 | 
						|
     ::=  {rndDeleteValuesEntry 4}
 | 
						|
 | 
						|
snmpTesting  OBJECT IDENTIFIER ::= { rndMidLevelManagement 9}
 | 
						|
 | 
						|
rndSimulatedVariablesTable  OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RndSimulatedVariablesEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This table indicates which MIB variables are simulated."
 | 
						|
    ::= {snmpTesting 1}
 | 
						|
 | 
						|
rndSimulatedVariablesEntry  OBJECT-TYPE
 | 
						|
   SYNTAX RndSimulatedVariablesEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " The row definition for the rndSimulatedVariablesTable table."
 | 
						|
   INDEX { rndSimulatedVariableEntryIndex }
 | 
						|
    ::= {rndSimulatedVariablesTable 1}
 | 
						|
 | 
						|
RndSimulatedVariablesEntry ::= SEQUENCE {
 | 
						|
 | 
						|
rndSimulatedVariableEntryIndex  INTEGER,
 | 
						|
rndSimulatedVariableObjectId    OBJECT IDENTIFIER,
 | 
						|
rndNotSupportedField            INTEGER,
 | 
						|
rndSimulatedVariableEntryStatus RowStatus
 | 
						|
}
 | 
						|
 | 
						|
rndSimulatedVariableEntryIndex OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The index entry."
 | 
						|
 | 
						|
     ::=  {rndSimulatedVariablesEntry 1}
 | 
						|
 | 
						|
rndSimulatedVariableObjectId OBJECT-TYPE
 | 
						|
   SYNTAX OBJECT IDENTIFIER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "The object id of the simulated variable. If the simulated variable belongs
 | 
						|
     to a table entry, the entire entry is henceforth supported."
 | 
						|
 | 
						|
     ::=  {rndSimulatedVariablesEntry 2}
 | 
						|
 | 
						|
rndNotSupportedField OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "Variable for not supported simulation."
 | 
						|
     ::=  {rndSimulatedVariablesEntry 3}
 | 
						|
 | 
						|
rndSimulatedVariableEntryStatus  OBJECT-TYPE
 | 
						|
   SYNTAX  RowStatus
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
         "It is used to delete an entry from this table."
 | 
						|
     ::=  {rndSimulatedVariablesEntry 4}
 | 
						|
 | 
						|
rndSnmpTestPassword  OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the user supplying the correct code to use the
 | 
						|
     SNMP test feature."
 | 
						|
    ::= {snmpTesting 2}
 | 
						|
 | 
						|
rndSnmpTests  OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER {
 | 
						|
                   noSimulation(1),
 | 
						|
                   simulateSetFailure(2),
 | 
						|
                   simulateAppGet(3),
 | 
						|
                   simulateAppGetNext(4)
 | 
						|
                  }
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the authorized user to test various SNMP features."
 | 
						|
    ::= {snmpTesting 3}
 | 
						|
 | 
						|
rndSimulateUndo  OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the authorized user to test the SNMP UNDO feature."
 | 
						|
    ::= {snmpTesting 4}
 | 
						|
 | 
						|
rlSnmpServTestRequest  OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the authorized user to test the SNMP SERV package."
 | 
						|
    ::= {snmpTesting 5}
 | 
						|
 | 
						|
rlSnmpServTestResponse  OBJECT-TYPE
 | 
						|
   SYNTAX OCTET STRING
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the authorized user to retrieve the results of
 | 
						|
    a the SNMP SERV package test."
 | 
						|
   ::= {snmpTesting 6}
 | 
						|
 | 
						|
rlSnmpServCreateTestPool  OBJECT-TYPE
 | 
						|
   SYNTAX INTEGER { create(1), no-create(2) }
 | 
						|
   MAX-ACCESS   read-write
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This variable enables the authorized user to indicate that after its reset
 | 
						|
     the device should create a buffer pool for SNMPServ process PDU
 | 
						|
     testing."
 | 
						|
   ::= {snmpTesting 7}
 | 
						|
 | 
						|
rlSnmpServITCbindClients  OBJECT-TYPE
 | 
						|
    SYNTAX OBJECT IDENTIFIER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "This variable enables the authorized user to to indicate that after
 | 
						|
         its reset the device should create ITC clients for SnmpServ data
 | 
						|
         requests clients.
 | 
						|
         The semantics of this variable is as follows:
 | 
						|
            subidentifier 2*n indicates whether the client n is synchronous(1) or
 | 
						|
            asynchronous(2)
 | 
						|
            subidentifier 2*n+1 indicates the number of simulatneous requests
 | 
						|
            expected by client n."
 | 
						|
    ::= {snmpTesting 8}
 | 
						|
 | 
						|
rlSnmpTestSimulatedVariables  OBJECT IDENTIFIER ::= {snmpTesting 9}
 | 
						|
 | 
						|
rlTstBasicRateTable OBJECT-TYPE
 | 
						|
    SYNTAX SEQUENCE OF RlTstBasicRateEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Table for testing SNMP agent."
 | 
						|
    ::= { snmpTesting 10 }
 | 
						|
 | 
						|
rlTstBasicRateEntry OBJECT-TYPE
 | 
						|
    SYNTAX RlTstBasicRateEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "An entry in the rlTstBasicRateTable."
 | 
						|
    INDEX { ifIndex }
 | 
						|
    ::= { rlTstBasicRateTable 1 }
 | 
						|
 | 
						|
RlTstBasicRateEntry ::= SEQUENCE {
 | 
						|
    rlTstBasicRateIfType INTEGER,
 | 
						|
    rlTstBasicRateLineTopology INTEGER,
 | 
						|
    rlTstBasicRateIfMode INTEGER,
 | 
						|
    rlTstBasicRateSignalMode INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
rlTstBasicRateIfType OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        isdns(75),
 | 
						|
        isdnu(76)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        ""
 | 
						|
    ::= { rlTstBasicRateEntry 1 }
 | 
						|
 | 
						|
rlTstBasicRateLineTopology OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        pointToPoint(1),
 | 
						|
        pointToMultipoint(2)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        ""
 | 
						|
    ::= { rlTstBasicRateEntry 2 }
 | 
						|
 | 
						|
rlTstBasicRateIfMode OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        te(1),
 | 
						|
        nt(2)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        ""
 | 
						|
    ::= { rlTstBasicRateEntry 3 }
 | 
						|
 | 
						|
rlTstBasicRateSignalMode OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
        active(1),
 | 
						|
        inactive(2)
 | 
						|
        }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        ""
 | 
						|
    ::= { rlTstBasicRateEntry 4 }
 | 
						|
 | 
						|
rlMibTree OBJECT IDENTIFIER ::= {rndMidLevelManagement 10 }
 | 
						|
 | 
						|
rlMibTreeTable OBJECT-TYPE
 | 
						|
   SYNTAX SEQUENCE OF RlMibTreeEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
    "This reflects the MIB tree of the device."
 | 
						|
   ::= {rlMibTree 1 }
 | 
						|
 | 
						|
 | 
						|
rlMibTreeEntry OBJECT-TYPE
 | 
						|
   SYNTAX RlMibTreeEntry
 | 
						|
   MAX-ACCESS   not-accessible
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
       " Each row shows a tree relationsship in the MIB."
 | 
						|
   INDEX { rlMibTreeFather, rlMibTreeSonIndex }
 | 
						|
   ::= {rlMibTreeTable 1 }
 | 
						|
 | 
						|
   RlMibTreeEntry ::= SEQUENCE {
 | 
						|
 | 
						|
     rlMibTreeFather                 DisplayString,
 | 
						|
     rlMibTreeSonIndex               INTEGER,
 | 
						|
     rlMibTreeSon                    DisplayString,
 | 
						|
     rlMibTreeSonObjectId            OBJECT IDENTIFIER,
 | 
						|
     rlMibTreeGrandFather            DisplayString
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
 rlMibTreeFather OBJECT-TYPE
 | 
						|
     SYNTAX DisplayString
 | 
						|
     MAX-ACCESS         not-accessible
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
       " The father in a tree relation ship."
 | 
						|
     ::= {rlMibTreeEntry 1 }
 | 
						|
 | 
						|
 rlMibTreeSonIndex OBJECT-TYPE
 | 
						|
     SYNTAX INTEGER
 | 
						|
     MAX-ACCESS         not-accessible
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
       " Running index for this table."
 | 
						|
     ::= {rlMibTreeEntry 2 }
 | 
						|
 | 
						|
 rlMibTreeSon OBJECT-TYPE
 | 
						|
     SYNTAX DisplayString
 | 
						|
     MAX-ACCESS         read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
       " The son in a tree relation ship."
 | 
						|
     ::= {rlMibTreeEntry 3 }
 | 
						|
 | 
						|
 rlMibTreeSonObjectId OBJECT-TYPE
 | 
						|
     SYNTAX OBJECT IDENTIFIER
 | 
						|
     MAX-ACCESS         read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
       " The object identifier of the son in a tree relation ship."
 | 
						|
     ::= {rlMibTreeEntry 4}
 | 
						|
 | 
						|
 rlMibTreeGrandFather OBJECT-TYPE
 | 
						|
     SYNTAX DisplayString
 | 
						|
     MAX-ACCESS         read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
       " The grand father (i.e father's father) in a tree relation ship."
 | 
						|
     ::= {rlMibTreeEntry 5 }
 | 
						|
 | 
						|
 | 
						|
-- Obsolete
 | 
						|
-- rsIpZeroHopRouting  OBJECT IDENTIFIER ::= { rndApplications 3}
 | 
						|
 | 
						|
 | 
						|
rsPingMIB OBJECT IDENTIFIER ::= { rndApplications 4} -- NEW Group
 | 
						|
rsPingTable OBJECT-TYPE
 | 
						|
    SYNTAX SEQUENCE OF RsPingEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A table of ping request entries."
 | 
						|
    ::= { rsPingMIB 1 }
 | 
						|
 | 
						|
rsPingEntry OBJECT-TYPE
 | 
						|
    SYNTAX RsPingEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A ping request entry.
 | 
						|
 | 
						|
        A management station wishing to create an entry should
 | 
						|
        first generate a pseudo-random serial number to be used
 | 
						|
        as the index to this sparse table. It must also create in the same
 | 
						|
        PDU the associated instance of the address object. It should also
 | 
						|
        modify in the same PDU the default values for the other configuration
 | 
						|
        objects if the defaults are not appropriate.
 | 
						|
 | 
						|
        Once the sequence completes, the management station should
 | 
						|
        retrieve the values of the status objects of interest, and
 | 
						|
        should then delete the entry.  In order to prevent old
 | 
						|
        entries from clogging the table, entries will be aged out,
 | 
						|
        but an entry will never be deleted within 5 minutes of
 | 
						|
        completing."
 | 
						|
    INDEX { rsPingAddress }
 | 
						|
    ::= { rsPingTable 1 }
 | 
						|
 | 
						|
RsPingEntry ::= SEQUENCE {
 | 
						|
    rsPingAddress          IpAddress,
 | 
						|
    rsPingPacketCount      INTEGER,
 | 
						|
    rsPingPacketSize       INTEGER,
 | 
						|
    rsPingPacketTimeout    INTEGER,
 | 
						|
    rsPingDelay            INTEGER,
 | 
						|
    rsPingTrapOnCompletion TruthValue,
 | 
						|
    rsPingSentPackets      Counter32,
 | 
						|
    rsPingReceivedPackets  Counter32,
 | 
						|
    rsPingMinReturnTime    INTEGER,
 | 
						|
    rsPingAvgReturnTime    INTEGER,
 | 
						|
    rsPingMaxReturnTime    INTEGER,
 | 
						|
    rsPingCompletionStatus INTEGER,
 | 
						|
    rsPingTimeStamp        DisplayString,
 | 
						|
    rsPingEntryStatus      RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
rsPingAddress OBJECT-TYPE
 | 
						|
    SYNTAX IpAddress
 | 
						|
--    Rsyntax OCTET STRING
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The address of the device to be pinged.
 | 
						|
         Once an instance of this object is created, its
 | 
						|
         value can not be changed."
 | 
						|
    ::= { rsPingEntry 1 }
 | 
						|
 | 
						|
rsPingPacketCount OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER(1..2147483647)
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Specifies the number of ping packets to send to the target
 | 
						|
        in this sequence."
 | 
						|
--    DEFVAL { 5 }
 | 
						|
    ::= { rsPingEntry 2 }
 | 
						|
 | 
						|
 rsPingPacketSize OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Specifies the size of ping packets to send to the target
 | 
						|
        in this sequence.  The lower and upper boundaries of this
 | 
						|
        object are implementation dependent."
 | 
						|
--    DEFVAL { 100 }
 | 
						|
    ::= { rsPingEntry 3 }
 | 
						|
 | 
						|
rsPingPacketTimeout OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER(0..3600000)
 | 
						|
--  Units
 | 
						|
--    milliseconds
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Specifies the amount of time to wait for a response to a
 | 
						|
        transmitted packet before declaring the packet 'dropped.'"
 | 
						|
--    DEFVAL { 2000 }
 | 
						|
    ::= { rsPingEntry 4 }
 | 
						|
 | 
						|
rsPingDelay OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER(0..3600000)
 | 
						|
--  Units
 | 
						|
--    milliseconds
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "Specifies the minimum amount of time to wait before sending
 | 
						|
        the next packet in a sequence after receiving a response.
 | 
						|
        The actual delay may be greater due to internal task scheduling."
 | 
						|
--    DEFVAL { 0 }
 | 
						|
    ::= { rsPingEntry 5 }
 | 
						|
 | 
						|
rsPingTrapOnCompletion OBJECT-TYPE
 | 
						|
    SYNTAX TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "Specifies whether or not a rsPingCompletion trap should
 | 
						|
         be issued on completion of the sequence of pings.  If such a
 | 
						|
         trap is desired, the NMS should ensure that the community table
 | 
						|
         contains an instance specified by the NMSs IP address with
 | 
						|
         rndCommunityTrapsEnable = trapsEnable."
 | 
						|
--  DEFVAL { false }
 | 
						|
    ::= { rsPingEntry 6 }
 | 
						|
 | 
						|
rsPingSentPackets OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The number of ping packets that have been sent to the target
 | 
						|
        in this sequence."
 | 
						|
    ::= { rsPingEntry 7 }
 | 
						|
 | 
						|
rsPingReceivedPackets OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The number of ping packets that have been received from the
 | 
						|
        target in this sequence."
 | 
						|
    ::= { rsPingEntry 8 }
 | 
						|
 | 
						|
rsPingMinReturnTime OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
--  Units
 | 
						|
--    milliseconds
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The minimum round trip time of all the packets that have
 | 
						|
         been sent in this sequence. The value returned to a GET request
 | 
						|
         is meaningless if no ping response in a sequence has been received
 | 
						|
         yet."
 | 
						|
    ::= { rsPingEntry 9 }
 | 
						|
 | 
						|
rsPingAvgReturnTime OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
--  Units
 | 
						|
--    milliseconds
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The average round trip time of all the packets that have
 | 
						|
         been sent in this sequence.The value returned to a GET request
 | 
						|
         is meaningless if no ping response in a sequence has been received
 | 
						|
         yet."
 | 
						|
    ::= { rsPingEntry 10 }
 | 
						|
 | 
						|
rsPingMaxReturnTime OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
--  Units
 | 
						|
--    milliseconds
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The maximum round trip time of all the packets that have
 | 
						|
         been sent in this sequence.The value returned to a GET request
 | 
						|
         is meaningless if no ping response in a sequence has been received
 | 
						|
         yet."
 | 
						|
    ::= { rsPingEntry 11 }
 | 
						|
 | 
						|
rsPingCompletionStatus OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER {
 | 
						|
       ok(1),
 | 
						|
       timeout(2),
 | 
						|
       net-unreachable(3),
 | 
						|
       host-unreachable(4),
 | 
						|
       protocol-unreachable(5),
 | 
						|
       time-to-live-exceeded(6),
 | 
						|
       reassembly-time-exceeded(7),
 | 
						|
       unable-to-send(8),
 | 
						|
       bad-reply-data(9),
 | 
						|
       incomplete(10)
 | 
						|
       }
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "If all the echo request packets in this sequence have been
 | 
						|
         responded by valid echo responses, this object is set to ok.
 | 
						|
         Otherwise this status indicates the problem. bad-reply-data indicates
 | 
						|
         that the reply data is not equal to the response data."
 | 
						|
    ::= { rsPingEntry 12 }
 | 
						|
 | 
						|
rsPingTimeStamp OBJECT-TYPE
 | 
						|
    SYNTAX DisplayString(SIZE(19))
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The time-stamp indicating the time and date of creation or last
 | 
						|
         update of this request. The format of the time-stamp is
 | 
						|
         dd/mm/yyyy hh:mm:ss"
 | 
						|
    ::= { rsPingEntry 13 }
 | 
						|
 | 
						|
 | 
						|
rsPingEntryStatus OBJECT-TYPE
 | 
						|
    SYNTAX RowStatus
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The status of this table entry."
 | 
						|
    ::= { rsPingEntry 14 }
 | 
						|
 | 
						|
rsPowerSupplyRedundacy OBJECT IDENTIFIER ::= { rndApplications 5} -- NEW Group
 | 
						|
rsPowerSupplyRedundacyTable   OBJECT-TYPE
 | 
						|
    SYNTAX SEQUENCE OF RsPowerSupplyRedundacyEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The power supply redundancy table."
 | 
						|
    ::=  { rsPowerSupplyRedundacy 1  }
 | 
						|
 | 
						|
rsPowerSupplyRedundacyEntry OBJECT-TYPE
 | 
						|
    SYNTAX RsPowerSupplyRedundacyEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The status of power supply redundancy for this table."
 | 
						|
    INDEX { rsPowerSupplyRedundacyReNumber}
 | 
						|
    ::= { rsPowerSupplyRedundacyTable 1}
 | 
						|
 | 
						|
RsPowerSupplyRedundacyEntry ::= SEQUENCE {
 | 
						|
    rsPowerSupplyRedundacyReNumber       INTEGER,
 | 
						|
    rsPowerSupplyRedundacyStatus         INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
rsPowerSupplyRedundacyReNumber OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER  (1..31)
 | 
						|
    MAX-ACCESS          read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "This number identifies the module backed up
 | 
						|
         by power supply redundancy in the stack."
 | 
						|
    ::= { rsPowerSupplyRedundacyEntry 1}
 | 
						|
 | 
						|
rsPowerSupplyRedundacyStatus OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER{
 | 
						|
        notExist(1),
 | 
						|
        existButNotWorking(2),
 | 
						|
        bothWorking(3),
 | 
						|
        internalOnlyWorking(4),
 | 
						|
        externalOnlyWorking(5)
 | 
						|
        }
 | 
						|
    MAX-ACCESS          read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The status of a power supply redundancy of the entry."
 | 
						|
    ::= { rsPowerSupplyRedundacyEntry 2}
 | 
						|
 | 
						|
rsNvram  OBJECT IDENTIFIER ::= { rndApplications 6 }
 | 
						|
rsEraseNvramAfterReset OBJECT-TYPE
 | 
						|
    SYNTAX DisplayString  (SIZE(0..20))
 | 
						|
    MAX-ACCESS          read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The name of NVRAM application that will be erased
 | 
						|
         after reset or ALL if all NVRAM should be erased."
 | 
						|
    ::=  { rsNvram 1 }
 | 
						|
 | 
						|
rsNvramApplTable   OBJECT-TYPE
 | 
						|
    SYNTAX SEQUENCE OF RsNvramApplEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The NVRAM application table."
 | 
						|
    ::=  { rsNvram 2 }
 | 
						|
 | 
						|
rsNvramApplEntry OBJECT-TYPE
 | 
						|
    SYNTAX RsNvramApplEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The status of NVRAM application table."
 | 
						|
    INDEX { rsNvramApplIndex}
 | 
						|
    ::= { rsNvramApplTable 1}
 | 
						|
 | 
						|
RsNvramApplEntry ::= SEQUENCE {
 | 
						|
    rsNvramApplIndex       INTEGER,
 | 
						|
    rsNvramApplName        DisplayString
 | 
						|
    }
 | 
						|
 | 
						|
rsNvramApplIndex OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER
 | 
						|
    MAX-ACCESS          read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The index of NVRAM application table."
 | 
						|
    ::= { rsNvramApplEntry 1}
 | 
						|
 | 
						|
rsNvramApplName OBJECT-TYPE
 | 
						|
    SYNTAX DisplayString  (SIZE(0..20))
 | 
						|
    MAX-ACCESS          read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The name of application used NVRAM."
 | 
						|
    ::= { rsNvramApplEntry 2}
 | 
						|
 | 
						|
END
 | 
						|
 |