-- **  COPYRIGHT      (c) 2006 Rohde & Schwarz GmbH & Co. KG
 | 
						|
-- **                          Muehldorfstrasse 15
 | 
						|
-- **    R & S                 D-81671 Muenchen
 | 
						|
-- **
 | 
						|
-- *****************************************************************************
 | 
						|
-- **
 | 
						|
-- **  MODULE         RS-XX8000-DVB-TX-MIB
 | 
						|
-- **  
 | 
						|
-- **  DESCRIPTION    Rohde & Schwarz SNMP
 | 
						|
-- **
 | 
						|
-- **  HISTORY
 | 
						|
-- **
 | 
						|
-- **  2006-11-28 hue - initial version
 | 
						|
-- **  2007-03-08 hue - added low power, sorted groups
 | 
						|
-- **  2007-07-11 sr  - added cmdTxDelayTimeExcAutomatic, 
 | 
						|
-- **                         cmdTxDelayTimeOstAutomatic,
 | 
						|
-- **                         cmdExcTypeLossOfInput, 
 | 
						|
-- **                         cmdOstMaxOutletTempThreshold,
 | 
						|
-- **                         forwardPowerOstA, forwardPowerOstB,
 | 
						|
-- **                         reflectedPowerOstA, reflectedPowerOstB,
 | 
						|
-- **                   renamed ostRackTable to ostTable,
 | 
						|
-- **                           ostRackEntry to ostEntry,
 | 
						|
-- **                   added ostRackAmp... nodes
 | 
						|
-- **                   added productInfoTable, rfProbesTable
 | 
						|
-- **                   defined alarm class for txAutomaticExcChanged,
 | 
						|
-- **                                           txAutomaticOstChanged
 | 
						|
-- **                   added groupProductInfo, groupAmpMeasureValues,
 | 
						|
-- **                         groupRfProbes, groupSingleTxLPNoNetCCU,
 | 
						|
-- **                         groupAlarmSingleTxLPNoNetCCU, 
 | 
						|
-- **                         rsXx8000DVBSingleTxLPNoNetCCU
 | 
						|
-- **  2007-08-09 kp - expansion of ProductInfoTable
 | 
						|
-- **  2007-09-10 sr - remove forwardPowerOstA and reflectedPowerOstA
 | 
						|
-- **                  from groupSingleTxMP and groupDualDriveMP
 | 
						|
-- **  2007-12-07 sr - cmdExcSFNStaticDelay to FloatingPoint
 | 
						|
-- **                  cmdExcSFNDeviationTime changed range
 | 
						|
-- **                - new exciter commands for RfOutput, RfIqAdjust and Precorrection
 | 
						|
-- **                - rename prodInfoDeviceNameIdx to prodInfoModuleIdx and
 | 
						|
-- **                         prodInfoDeviceName to prodInfoModuleName
 | 
						|
-- **                  using TC ProdInfoModuleNameTv with a new value for netCCU 
 | 
						|
-- **                - rename txNetCCUBoardTemperatureWarning to
 | 
						|
-- **                         txNetCCUBoardTemperatureFault
 | 
						|
-- **                - new OBJECT-GROUPs groupExciterStatus and groupExciterPrecorrection
 | 
						|
-- **  2008-03-31 sr  - change range of cmdTxDelayTimeExcAutomatic and 
 | 
						|
-- **                   cmdTxDelayTimeOstAutomatic to 1..60
 | 
						|
-- **             ks - SLx extension
 | 
						|
-- **  2008-05-05 sr - cmdExcReferenceSource with value internGPS
 | 
						|
-- **  2008-06-11 ks - cmdExcInput1Source, cmdExcInput2Source added
 | 
						|
-- **  2008-07-23 sr - new SLx parameters: cmdExcTimeScheduler, configurationTable and
 | 
						|
-- **                                      timeSchedulerTable
 | 
						|
-- **                - new SFN Delay parameters in exciterStatusTable
 | 
						|
-- **  2008-08-26 ks - rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2 read-only
 | 
						|
-- **                          - cmdTxParametersetReSave obsolete
 | 
						|
-- **  2008-07-29 hu - changed TextualConvention for Exciter LogbookEntryMessages
 | 
						|
-- **  2008-09-10 sr - new rackTable
 | 
						|
-- **                - new txRackRfWarning, txRackRfFault, txRackReflectionWarning,
 | 
						|
-- **                      txRackReflectionFault
 | 
						|
-- **                - new groupIndependentRacks 
 | 
						|
-- **  2008-10-08 sr - cmdExcFrequency and configFrequency range up to 1500 MHz
 | 
						|
-- **  2008-10-23 ks - new: cmdExcInpAutoReadyAfterChangeOv,
 | 
						|
-- **                       txExcInputAutomaticSwitchReady, txExcInputAutomaticChangedOver
 | 
						|
-- **  2008-12-12 sr - rfProbeConfigurationLabel obsolete
 | 
						|
-- **                - txRackExtCoolingWarning renamed to txRackGpiWarning
 | 
						|
-- **                - txRackExtCoolingFault renamed to txRackGpiFault
 | 
						|
-- **  2009-01-06 sr - rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset
 | 
						|
-- **  2009-02-12 sr - InputSource with value tp
 | 
						|
-- **                - new groupExcCommandsAdditional
 | 
						|
-- **  2009-03-30 ks - txRackProbeNotCalibrated added
 | 
						|
-- **                - txParamSetSubDeviceDiffers obsoleted
 | 
						|
-- **  2009-05-28 ks -information for additional (external) power supply added
 | 
						|
-- **                - txRackRfOn, txRackRfOk, txRackTemperatureWarning added
 | 
						|
-- **  2009-06-17 ks - object groups, notification groups and
 | 
						|
-- **                  module compliances reorganized
 | 
						|
-- **  2009-06-26 ks - consideration of face-lift configuration in module compliances
 | 
						|
-- **                - measured values for power supply added
 | 
						|
-- **                - cmdExcInputAutoSwitch obsoleted
 | 
						|
-- **                - conditional groupDummyLoadRF added
 | 
						|
-- **  2009-07-16 ks - additional values for reserve concept 'backup exciter'
 | 
						|
-- **  2009-09-10 ks - cmdTxSystemMode added
 | 
						|
-- **                - traps for TX mode switch over added
 | 
						|
-- **  2009-10-08 ks - txRackOvervoltProtectWarning added
 | 
						|
-- **                - cmdExcInputAutoSwitch obsoleted
 | 
						|
-- **  2009-11-13 ks - ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase added
 | 
						|
-- **  2009-11-26 ks - cmdExcRfFailLimit, cmdExcRfWarningLimit added
 | 
						|
-- **  2009-11-27 ks - cmdExcInputFailDelayTime added
 | 
						|
-- **  2009-11-30 ks - cmdExcMonitoringOutput, cmdExcOcxoAdjust added
 | 
						|
-- **  2009-12-01 ks - configRxFrequency, configInputSource added
 | 
						|
-- **  2009-12-04 ks - configuration2Table added
 | 
						|
-- **  2009-12-07 ks - excStatusNominalPower added
 | 
						|
-- **  2009-12-18 ks - txExcRfOk added
 | 
						|
-- **  2010-01-12 ks - excStatusVSWR added
 | 
						|
-- **  2010-01-29 ks - txNetCCUBoardTemperatureFault deprecated,
 | 
						|
-- **                  txNetCCUBoardTemperatureWarning added
 | 
						|
-- **  2010-02-02 ks - cmdExcExpectInputReserve, txExcInputReseveMissing added
 | 
						|
-- **  2010-20-04 ks - cmdExcMuteCondition added
 | 
						|
-- **  2010-05-21 ks - cmdTxRfSwitch added
 | 
						|
-- **  2010-10-13 ks - cmdExcEnablePcrReset, cmdExcTimeForDailyPcrReset added
 | 
						|
-- **  2010-12-02 ks - excStatusAmplifierControl, excStatusReqDataRateHP,
 | 
						|
-- **                  excStatusReqDataRateLP added
 | 
						|
-- **  2011-02-28 ks - Amplifier status for Sx801 added.
 | 
						|
-- **  2011-05-12 ks - cmdExcFailDelayMode, excStatusFailDelay added
 | 
						|
-- **  2012-09-03 ks - sx801AmplifierTable measured values added
 | 
						|
-- **  2012-11-01 ks - Hierarchical input is no longer supported.
 | 
						|
-- *****************************************************************************
 | 
						|
-- *****************************************************************************
 | 
						|
 | 
						|
    RS-XX8000-DVB-TX-MIB DEFINITIONS ::= BEGIN
 | 
						|
 
 | 
						|
        IMPORTS
 | 
						|
            rsXx8000, eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, 
 | 
						|
            indexRack, indexAmplifier, rsXx8000MibModule, ReadableString, FloatingPoint, 
 | 
						|
            LogbookEntryMessagesNetCCU, LogbookEntryMessagesOST, LogbookEntrySlope, EventMaxEntryNumber, SwitchOnOff, 
 | 
						|
            Trigger, EventMask, EventPriority, EventState, EventClass, 
 | 
						|
            IndexRack, IndexAmplifier, IndexAB, LogbookMaxEntryNumber, ProdInfoModuleNameTv, 
 | 
						|
            EqualizerCalibrationState, TvStandard, LogbookEntryMessagesExcTv, InputSource, TimeOfDay, 
 | 
						|
            Sx801AmplifierState, FailDelayMode, FailDelayStatus            
 | 
						|
                FROM RS-XX8000-COMMON-MIB            
 | 
						|
            OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP            
 | 
						|
                FROM SNMPv2-CONF            
 | 
						|
            Integer32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE            
 | 
						|
                FROM SNMPv2-SMI            
 | 
						|
            DateAndTime, TruthValue, RowStatus            
 | 
						|
                FROM SNMPv2-TC;
 | 
						|
    
 | 
						|
    
 | 
						|
        rsXx8000DvbTxMibModule MODULE-IDENTITY 
 | 
						|
            LAST-UPDATED "201211010800Z"		-- November 01, 2012 at 08:00 GMT
 | 
						|
            ORGANIZATION 
 | 
						|
                "Rohde&Schwarz GmbH & Co. KG"
 | 
						|
            CONTACT-INFO 
 | 
						|
                "Torsten Huebscher
 | 
						|
                Department 7TS2
 | 
						|
                Broadcasting Division
 | 
						|
                Muehldorfstrasse 15
 | 
						|
                81671 Munich, Germany
 | 
						|
                torsten.huebscher@rohde-schwarz.com"
 | 
						|
            DESCRIPTION 
 | 
						|
                "This MIB defines transmitting systems from Rohde & Schwarz.
 | 
						|
                
 | 
						|
                Use this MIB if your system meets the following requirements:
 | 
						|
                - series XX8000 (NetCCU800),
 | 
						|
                - DVB,
 | 
						|
                - transmitter reserve concept SingleTx, DualDrive,
 | 
						|
                  Active Reserve or Passive Reserve.
 | 
						|
                
 | 
						|
                The following MIBs are related to this:
 | 
						|
                - RS-COMMON-MIB         - mandatory for this MIB
 | 
						|
                - RS-XX8000-COMMON-MIB  - mandatory for this MIB"
 | 
						|
            REVISION "201211010800Z"		-- November 01, 2012 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "Hierarchical input is no longer supported."
 | 
						|
            REVISION "201209030800Z"		-- September 03, 2012 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "sx801AmplifierTable measured values added"
 | 
						|
            REVISION "201105120800Z"		-- May 12, 2011 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcFailDelayMode, excStatusFailDelay added"
 | 
						|
            REVISION "201102280800Z"		-- February 28, 2011 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "Amplifier status for Sx801 added."
 | 
						|
            REVISION "201012020800Z"		-- December 02, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "excStatusAmplifierControl, excStatusReqDataRateHP,
 | 
						|
                excStatusReqDataRateLP added"
 | 
						|
            REVISION "201010130800Z"		-- October 13, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcEnablePcrReset, cmdExcTimeForDailyPcrReset added"
 | 
						|
            REVISION "201005210800Z"		-- May 21, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdTxRfSwitch added"
 | 
						|
            REVISION "201004160800Z"		-- April 16, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcMuteCondition added"
 | 
						|
            REVISION "201002020800Z"		-- February 02, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcExpectInputReserve, txExcInputReseveMissing added"
 | 
						|
            REVISION "201001290800Z"		-- January 29, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "txNetCCUBoardTemperatureFault deprecated,
 | 
						|
                txNetCCUBoardTemperatureWarning added"
 | 
						|
            REVISION "201001120800Z"		-- January 12, 2010 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "excStatusVSWR added"
 | 
						|
            REVISION "200912180800Z"		-- December 18, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "txExcRfOk added"
 | 
						|
            REVISION "200911260800Z"		-- November 26, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcRfFailLimit, cmdExcRfWarningLimit,
 | 
						|
                cmdExcInputFailDelayTime, cmdExcMonitoringOutput,
 | 
						|
                cmdExcOcxoAdjust, configRxFrequency,
 | 
						|
                configInputSource, configuration2Table,
 | 
						|
                excStatusNominalPower  added"
 | 
						|
            REVISION "200911130800Z"		-- November 13, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase added"
 | 
						|
            REVISION "200910080800Z"		-- October 08, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "txRackOvervoltProtectWarning added
 | 
						|
                cmdExcInputAutoSwitch obsoleted"
 | 
						|
            REVISION "200909100800Z"		-- September 10, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdTxSystemMode added
 | 
						|
                traps for TX mode switch over added"
 | 
						|
            REVISION "200907160800Z"		-- July 16, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional values for reserve concept 'backup exciter'"
 | 
						|
            REVISION "200906260800Z"		-- June 26, 2009 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "consideration of face-lift configuration in module compliances,
 | 
						|
                measured values for power supply added,
 | 
						|
                cmdExcInputAutoSwitch obsoleted,
 | 
						|
                conditional groupDummyLoadRF added"
 | 
						|
            REVISION "200906170900Z"		-- June 17, 2009 at 09:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "object groups, notification groups and module compliances reorganized"
 | 
						|
            REVISION "200905280900Z"		-- May 28, 2009 at 09:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "information for additional (external) power supply added
 | 
						|
                txRackRfOn, txRackRfOk, txRackTemperatureWarning added"
 | 
						|
            REVISION "200903300900Z"		-- March 30, 2009 at 09:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "txRackProbeNotCalibrated added
 | 
						|
                txParamSetSubDeviceDiffers obsoleted"
 | 
						|
            REVISION "200902121500Z"		-- February 12, 2009 at 15:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- InputSource with value tp
 | 
						|
                - new groupExcCommandsAdditional"
 | 
						|
            REVISION "200901290900Z"		-- January 29, 2009 at 09:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "MODULE COMPLIANCE rsXx8000DVBReEquip"
 | 
						|
            REVISION "200901061600Z"		-- January 06, 2009 at 16:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset"
 | 
						|
            REVISION "200812121430Z"		-- December 12, 2008 at 14:30 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "rfProbeConfigurationLabel obsolete
 | 
						|
                txRackExtCoolingWarning renamed to txRackGpiWarning
 | 
						|
                txRackExtCoolingFault renamed to txRackGpiFault"
 | 
						|
            REVISION "200810230800Z"		-- October 23, 2008 at 08:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcInpAutoReadyAfterChangeOv
 | 
						|
                txExcInputAutomaticSwitchReady, txExcInputAutomaticChangedOver"
 | 
						|
            REVISION "200810081030Z"		-- October 08, 2008 at 10:30 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "cmdExcFrequency and configFrequency range up to 1500 MHz"
 | 
						|
            REVISION "200809101500Z"		-- September 10, 2008 at 15:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "new rackTable
 | 
						|
                new txRackRfWarning, txRackRfFault, txRackReflectionWarning,
 | 
						|
                    txRackReflectionFault
 | 
						|
                new groupIndependentRacks"
 | 
						|
            REVISION "200808291000Z"		-- August 29, 2008 at 10:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "changed TextualConvention for Exciter LogbookEntryMessages"
 | 
						|
            REVISION "200808260900Z"		-- August 26, 2008 at 09:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2 read-only
 | 
						|
                - cmdTxParametersetReSave obsolete"
 | 
						|
            REVISION "200807231000Z"		-- July 23, 2008 at 10:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- new SLx parameters: cmdExcTimeScheduler, configurationTable and
 | 
						|
                                      timeSchedulerTable
 | 
						|
                - new SFN Delay parameters in exciterStatusTable"
 | 
						|
            REVISION "200805050930Z"		-- May 05, 2008 at 09:30 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- cmdExcReferenceSource with value internGPS
 | 
						|
                - cmdExcInput1Source, cmdExcInput2Source added"
 | 
						|
            REVISION "200803311100Z"		-- March 31, 2008 at 11:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- change range of cmdTxDelayTimeExcAutomatic and 
 | 
						|
                  cmdTxDelayTimeOstAutomatic to 1..60
 | 
						|
                - adds cmdExcTransmitterType, cmdExcOutputPower
 | 
						|
                  excPrecUserState, excPrecFactoryState, excPrecRestoreCurrentSettings, excPrecRestoreAllSettings"
 | 
						|
            REVISION "200712071700Z"		-- December 07, 2007 at 17:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- cmdExcSFNStaticDelay to FloatingPoint
 | 
						|
                  cmdExcSFNDeviationTime changed range
 | 
						|
                - new exciter commands for RfOutput, RfIqAdjust and Precorrection
 | 
						|
                - rename prodInfoDeviceNameIdx to prodInfoModuleIdx and
 | 
						|
                         prodInfoDeviceName to prodInfoModuleName
 | 
						|
                  using TC ProdInfoModuleNameTv with a new value for netCCU 
 | 
						|
                - rename txNetCCUBoardTemperatureWarning to
 | 
						|
                         txNetCCUBoardTemperatureFault
 | 
						|
                - new OBJECT-GROUPs groupExciterStatus and groupExciterPrecorrection"
 | 
						|
            REVISION "200709101100Z"		-- September 10, 2007 at 11:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "remove forwardPowerOstA and reflectedPowerOstA from groupSingleMP and groupDualDriveMP"
 | 
						|
            REVISION "200708091400Z"		-- August 09, 2007 at 14:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "Expansion of ProductInfoTable"
 | 
						|
            REVISION "200707111600Z"		-- July 11, 2007 at 16:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "added cmdTxDelayTimeExcAutomatic,
 | 
						|
                      cmdTxDelayTimeOstAutomatic,
 | 
						|
                      cmdExcTypeLossOfInput,
 | 
						|
                      cmdOstMaxOutletTempThreshold,
 | 
						|
                      forwardPowerOstA, forwardPowerOstB,
 | 
						|
                      reflectedPowerOstA, reflectedPowerOstB,
 | 
						|
                renamed ostRackTable to ostTable,
 | 
						|
                        ostRackEntry to ostEntry,
 | 
						|
                added ostRackAmp... nodes
 | 
						|
                added productInfoTable, rfProbesTable
 | 
						|
                defined alarm class for txAutomaticExcChanged,
 | 
						|
                                        txAutomaticOstChanged
 | 
						|
                added groupProductInfo, groupAmpMeasureValues,
 | 
						|
                      groupRfProbes, groupSingleTxLPNoNetCCU,
 | 
						|
                      groupAlarmSingleTxLPNoNetCCU,
 | 
						|
                      rsXx8000DVBSingleTxLPNoNetCCU"
 | 
						|
            REVISION "200703081000Z"		-- March 08, 2007 at 10:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "- Added LowPower
 | 
						|
                - Sorted groups"
 | 
						|
            REVISION "200612211000Z"		-- December 21, 2006 at 10:00 GMT
 | 
						|
            DESCRIPTION 
 | 
						|
                "This is the initial version."
 | 
						|
            ::= { rsXx8000MibModule 3 }
 | 
						|
 | 
						|
        
 | 
						|
    
 | 
						|
    
 | 
						|
--
 | 
						|
-- Node definitions
 | 
						|
--
 | 
						|
    
 | 
						|
        rsXx8000DvbTx OBJECT-IDENTITY
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Xx8000 DVB transmitter."
 | 
						|
            ::= { rsXx8000 4 }
 | 
						|
 | 
						|
        
 | 
						|
-- *****************************************************************************
 | 
						|
-- **          object definitions
 | 
						|
-- *****************************************************************************
 | 
						|
        rsXx8000DvbTxObjs OBJECT IDENTIFIER ::= { rsXx8000DvbTx 1 }
 | 
						|
 | 
						|
        
 | 
						|
        commandsTxTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF CommandsTxEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This table contains important commands for the transmitter."
 | 
						|
            ::= { rsXx8000DvbTxObjs 1 }
 | 
						|
 | 
						|
        
 | 
						|
        commandsTxEntry OBJECT-TYPE
 | 
						|
            SYNTAX CommandsTxEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for a designated transmitter and device."
 | 
						|
            INDEX { cmdDeviceIdx }
 | 
						|
            ::= { commandsTxTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        CommandsTxEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                cmdTxResetSumFault
 | 
						|
                    Trigger,
 | 
						|
                cmdTxParametersetLoad
 | 
						|
                    Integer32,
 | 
						|
                cmdTxParametersetSave
 | 
						|
                    Integer32,
 | 
						|
                cmdTxParametersetReSave
 | 
						|
                    Trigger,
 | 
						|
                cmdTxOperationModeProgram
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdTxOperationModeReserve
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdTxOpModeExcAutomatic
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdTxOpModeOstAutomatic
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdTxPreselectExciter
 | 
						|
                    IndexAB,
 | 
						|
                cmdTxPreselectOutputstage
 | 
						|
                    INTEGER,
 | 
						|
                cmdTxDelayTimeExcAutomatic
 | 
						|
                    Integer32,
 | 
						|
                cmdTxDelayTimeOstAutomatic
 | 
						|
                    Integer32,
 | 
						|
                cmdTxRfSwitch
 | 
						|
                    INTEGER,
 | 
						|
                cmdTxSystemMode
 | 
						|
                    TvStandard,
 | 
						|
                cmdTxProgramExciterPrio
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdTxChangeOver
 | 
						|
                    Trigger,
 | 
						|
                cmdTxSwitchPosition
 | 
						|
                    INTEGER,
 | 
						|
                cmdDeviceIdx
 | 
						|
                    IndexAB,
 | 
						|
                cmdExcOpModeInputAutomatic
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcPreselectInput
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcMode
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcNetworkMode
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSSource
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcEnableCellID
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcTxAddress
 | 
						|
                    Integer32,
 | 
						|
                cmdExcTxAutomatic
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcInputAutoSwitch
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcInputSeamless
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcInputPriority
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcInputCheckTimeForward
 | 
						|
                    Integer32,
 | 
						|
                cmdExcInputCheckTimeSwitchback
 | 
						|
                    Integer32,
 | 
						|
                cmdExcInputMuteOnFail
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcInputManualPreseletionHP1
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcInputManualPreseletionHP2
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcInputManualPreseletionLP1
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcInputManualPreseletionLP2
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualBandwidth
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualFFTLength
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualGuardInterval
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualConstellation
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualAlpha
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualCellID
 | 
						|
                    Integer32,
 | 
						|
                cmdExcTPSManualInterleaver
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualCoderateHP
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualCoderateLP
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTPSManualTimeSlicingHP
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcTPSManualTimeSlicingLP
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcTPSManualFECHP
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcTPSManualFECLP
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcSFNStaticDelay
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcSFNDeviationTime
 | 
						|
                    Integer32,
 | 
						|
                cmdExcFrequency
 | 
						|
                    Integer32,
 | 
						|
                cmdExcReferenceSource
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcMuteOnPPSFail
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcMuteOnReferenceFail
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcRefFailDelayTime
 | 
						|
                    Integer32,
 | 
						|
                cmdExcTypeLossOfInput
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcRfOutput
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcRfOutputRegulation
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcRfOutputManualRfLevel
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcRfOutputAttenuation
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfOutputRfSlope
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcRfOutputModulationSlope
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcRfIqAdjustStart
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcRfIqAdjustTestsignal
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcRfIqAdjustBiasCoarseI
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustBiasCoarseQ
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustBiasFineI
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustBiasFineQ
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustGainI
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustGainQ
 | 
						|
                    Integer32,
 | 
						|
                cmdExcRfIqAdjustPhase
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcInput1Source
 | 
						|
                    InputSource,
 | 
						|
                cmdExcInput2Source
 | 
						|
                    InputSource,
 | 
						|
                cmdExcInpAutoReadyAfterChangeOv
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcInputFailDelayTime
 | 
						|
                    Integer32,
 | 
						|
                cmdExcTransmitterType
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcTimeScheduler
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcMuteCondition
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcRfWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcRfFailLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdExcOutputPower
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdOstRefVoltageVision
 | 
						|
                    FloatingPoint,
 | 
						|
                cmdOstMaxOutletTempThreshold
 | 
						|
                    Integer32,
 | 
						|
                cmdExcMonitoringOutput
 | 
						|
                    INTEGER,
 | 
						|
                cmdExcOcxoAdjust
 | 
						|
                    Integer32,
 | 
						|
                cmdExcExpectInputReserve
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcEnablePcrReset
 | 
						|
                    SwitchOnOff,
 | 
						|
                cmdExcTimeForDailyPcrReset
 | 
						|
                    TimeOfDay,
 | 
						|
                cmdExcFailDelayMode
 | 
						|
                    FailDelayMode
 | 
						|
             }
 | 
						|
 | 
						|
        cmdTxResetSumFault OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Reset all faults (in all modules) of the transmitter.
 | 
						|
                
 | 
						|
                You reset a designated transmitter (NetCCU, Exciters, Outputstages).
 | 
						|
                An equivalent would be pressing RESET at this transmitters frontpanel.
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { commandsTxEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxParametersetLoad OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..8)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This loads the desired parameter set."
 | 
						|
            ::= { commandsTxEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxParametersetSave OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..8)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This saves the current settings to a designated parameter set."
 | 
						|
            ::= { commandsTxEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxParametersetReSave OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "This saves the changes to the current parameter set."
 | 
						|
            ::= { commandsTxEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxOperationModeProgram OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This switches the program path of the transmitter on/off."
 | 
						|
            ::= { commandsTxEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxOperationModeReserve OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This switches the reserve path of the transmitter on/off."
 | 
						|
            ::= { commandsTxEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxOpModeExcAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This switches the exciter automatic on/off."
 | 
						|
            ::= { commandsTxEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxOpModeOstAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This switches the outputstage automatic on/off.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { commandsTxEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxPreselectExciter OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets exciterA or exciterB to program path (antenna) of the transmitter."
 | 
						|
            ::= { commandsTxEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxPreselectOutputstage OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                outputstageA(1),
 | 
						|
                outputstageB(2),
 | 
						|
                bothToAntenna(3),
 | 
						|
                bothToDummyLoad(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets 
 | 
						|
                - outputstageA or 
 | 
						|
                - outputstageB or
 | 
						|
                - both
 | 
						|
                to program path (antenna) of the transmitter,
 | 
						|
                or it sets both to dummyload.
 | 
						|
                
 | 
						|
                The settings bothToAntenna(3) and bothToDummyLoad(4) are only settable 
 | 
						|
                for ActiveReserve systems.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { commandsTxEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxDelayTimeExcAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..60)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the exciter automatic delay time."
 | 
						|
            ::= { commandsTxEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxDelayTimeOstAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..60)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the outputstage automatic delay time.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { commandsTxEntry 12 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxRfSwitch OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                antenna(1),
 | 
						|
                dummyLoad(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "RF switch for single-ended systems."
 | 
						|
            ::= { commandsTxEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxSystemMode OBJECT-TYPE
 | 
						|
            SYNTAX TvStandard
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This object gives you the possibility of switching the TV standard
 | 
						|
                of a whole system with NetCCU with only one command.
 | 
						|
                Not applicable for N+1 or NTx systems.
 | 
						|
                The value 'test' cannot be written."
 | 
						|
            ::= { commandsTxEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxProgramExciterPrio OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables/Disables priority usage of program exciter"
 | 
						|
            ::= { commandsTxEntry 20 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxChangeOver OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Performs a change over"
 | 
						|
            ::= { commandsTxEntry 21 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdTxSwitchPosition OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                undefined(1),
 | 
						|
                controlExcOnAmp(2),
 | 
						|
                programExcOnAmp(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the actual switch position.
 | 
						|
                The program exciter is connected to input 1 (RF IN 1),
 | 
						|
                the control exciter is connected to input 2 (RF IN 2) of the base amplifier."
 | 
						|
            ::= { commandsTxEntry 22 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdDeviceIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This column is used to show parameters for both exiters, if you have 
 | 
						|
                dualdrive transmitters."
 | 
						|
            ::= { commandsTxEntry 30 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcOpModeInputAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Activates/deactivates the input automatic.
 | 
						|
                If input automatic is active 
 | 
						|
                and a loss of input signal is detected on the current input
 | 
						|
                the reserve input will be used instead."
 | 
						|
            ::= { commandsTxEntry 31 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcPreselectInput OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                input1(1),
 | 
						|
                input2(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the preselection of a transmitters input."
 | 
						|
            ::= { commandsTxEntry 32 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcMode OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                dvbT(1),
 | 
						|
                dvbH(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Switch between DVB-T and DVB-H."
 | 
						|
            ::= { commandsTxEntry 33 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcNetworkMode OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                mfn(1),
 | 
						|
                sfn(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Switch between Single Frequency Networks (SFN) and 
 | 
						|
                Multiple Frequency Networks (MFN)."
 | 
						|
            ::= { commandsTxEntry 34 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSSource OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                manualPresets(1),
 | 
						|
                mip(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Transmitted TPS parameters can be adjusted manually inside 
 | 
						|
                the transmitter or automatically via MIP from the SFN adaptor."
 | 
						|
            ::= { commandsTxEntry 35 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcEnableCellID OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This enables the Cell ID insertion. 
 | 
						|
                The length indicator will be adjusted."
 | 
						|
            ::= { commandsTxEntry 36 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTxAddress OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..65535)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the unique address of the transmitter 
 | 
						|
                to reference specific settings in the MIP."
 | 
						|
            ::= { commandsTxEntry 37 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTxAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This enables Tx specific parameters from the 
 | 
						|
                MIP data caroussel (e.g. time offset, frequency offset)."
 | 
						|
            ::= { commandsTxEntry 38 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputAutoSwitch OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS deprecated
 | 
						|
            DESCRIPTION
 | 
						|
                "Activates/deactivates the input automatic.
 | 
						|
                If input automatic is active 
 | 
						|
                and a loss of input signal is detected on the current input
 | 
						|
                the reserve input will be used instead.
 | 
						|
                
 | 
						|
                This object is deprecated. It's recommended to use cmdExcOpModeInputAutomatic instead."
 | 
						|
            ::= { commandsTxEntry 39 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputSeamless OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If the datastreams on both inputs are syncronised a seamless switch is possible. 
 | 
						|
                With this parameter the seamless switch can be suppressed to enable a check of the input automatic."
 | 
						|
            ::= { commandsTxEntry 40 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputPriority OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                equal(1),
 | 
						|
                prior(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Equal: There are no differences between both inputs. 
 | 
						|
                       If a failure on the current input is detected it will be switched to the reserve input. 
 | 
						|
                       It stays there until the reserve shows a failure. 
 | 
						|
                Prior: Whenever possible a certain input shall be used. 
 | 
						|
                       If a failure is detected the reserve will be used as short as possible."
 | 
						|
            ::= { commandsTxEntry 41 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputCheckTimeForward OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..600)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This time has to elapse before the current input switches 
 | 
						|
                to the reserve input."
 | 
						|
            ::= { commandsTxEntry 42 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputCheckTimeSwitchback OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..600)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This time has to elapse before the automatic switches back 
 | 
						|
                from the reserve to a preselected input. 
 | 
						|
                This value has no effect if the priority is set to equal."
 | 
						|
            ::= { commandsTxEntry 43 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputMuteOnFail OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                mute(1),
 | 
						|
                noMute(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If a loss of input signal is detected, the exciter mutes."
 | 
						|
            ::= { commandsTxEntry 44 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputManualPreseletionHP1 OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                auto(1),
 | 
						|
                asi(2),
 | 
						|
                smpte(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The data format of the input can be detected 
 | 
						|
                automatically or can be set manually to ASI or SMPTE."
 | 
						|
            ::= { commandsTxEntry 45 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputManualPreseletionHP2 OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                auto(1),
 | 
						|
                asi(2),
 | 
						|
                smpte(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The data format of the input can be detected 
 | 
						|
                automatically or can be set manually to ASI or SMPTE."
 | 
						|
            ::= { commandsTxEntry 46 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputManualPreseletionLP1 OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                auto(1),
 | 
						|
                asi(2),
 | 
						|
                smpte(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The data format of the input can be detected 
 | 
						|
                automatically or can be set manually to ASI or SMPTE."
 | 
						|
            ::= { commandsTxEntry 47 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputManualPreseletionLP2 OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                auto(1),
 | 
						|
                asi(2),
 | 
						|
                smpte(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The data format of the input can be detected 
 | 
						|
                automatically or can be set manually to ASI or SMPTE."
 | 
						|
            ::= { commandsTxEntry 48 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualBandwidth OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                mhz5(1),
 | 
						|
                mhz6(2),
 | 
						|
                mhz7(3),
 | 
						|
                mhz8(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The bandwidth used by the RF channel."
 | 
						|
            ::= { commandsTxEntry 49 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualFFTLength OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                k2(1),
 | 
						|
                k8(2),
 | 
						|
                k4(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The used FFT length (depends on the DVB network)."
 | 
						|
            ::= { commandsTxEntry 50 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualGuardInterval OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                oneOf32(1),
 | 
						|
                oneOf16(2),
 | 
						|
                oneOf8(3),
 | 
						|
                oneOf4(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Guard interval affects the error correction in multipath receiving situations.
 | 
						|
                A long Guard Interval reduces the amount of payload data."
 | 
						|
            ::= { commandsTxEntry 51 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualConstellation OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                qpsk(1),
 | 
						|
                qam16(2),
 | 
						|
                qam64(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This parameter sets the modulation mode."
 | 
						|
            ::= { commandsTxEntry 52 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualAlpha OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                noHierarchy(1),
 | 
						|
                one(2),
 | 
						|
                two(3),
 | 
						|
                four(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "An alpha greater than noHierarchy(1) enables the hierarchical coding mode."
 | 
						|
            ::= { commandsTxEntry 53 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualCellID OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..65535)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Via Cell ID the receiver knows the current network."
 | 
						|
            ::= { commandsTxEntry 54 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualInterleaver OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                indepth(1),
 | 
						|
                nat(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the bit interleaver for hierarchical coding"
 | 
						|
            ::= { commandsTxEntry 55 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualCoderateHP OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                oneOf2(1),
 | 
						|
                twoOf3(2),
 | 
						|
                threeOf4(3),
 | 
						|
                fiveOf6(4),
 | 
						|
                sevenOf8(5)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Code Rate sets the ratio between payload and error correction information."
 | 
						|
            ::= { commandsTxEntry 56 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualCoderateLP OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                oneOf2(1),
 | 
						|
                twoOf3(2),
 | 
						|
                threeOf4(3),
 | 
						|
                fiveOf6(4),
 | 
						|
                sevenOf8(5)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Code Rate sets the ratio between payload and error correction information."
 | 
						|
            ::= { commandsTxEntry 57 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualTimeSlicingHP OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the time slicing for hierarchical coding."
 | 
						|
            ::= { commandsTxEntry 58 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualTimeSlicingLP OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the time slicing for hierarchical coding."
 | 
						|
            ::= { commandsTxEntry 59 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualFECHP OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the forward error correction (FEC) for hierarchical coding."
 | 
						|
            ::= { commandsTxEntry 60 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTPSManualFECLP OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the forward error correction (FEC) for hierarchical coding."
 | 
						|
            ::= { commandsTxEntry 61 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcSFNStaticDelay OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A constant adjustable delay for tuning a SFN (-999999.9 ... 999999.9)."
 | 
						|
            ::= { commandsTxEntry 62 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcSFNDeviationTime OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..100)
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Leap In Time.
 | 
						|
                This parameter sets the deviation in time when a readjustment 
 | 
						|
                of the dynamic delay is necessary."
 | 
						|
            ::= { commandsTxEntry 63 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcFrequency OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (47000000..1500000000)
 | 
						|
            UNITS "Hertz"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the RF frequency."
 | 
						|
            ::= { commandsTxEntry 64 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcReferenceSource OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                intern(1),
 | 
						|
                extern5Mhz(2),
 | 
						|
                extern10Mhz(3),
 | 
						|
                extern1PPS(4),
 | 
						|
                internGPS(5)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Source of the reference signal.
 | 
						|
                The value internGPS is not valid for SX800."
 | 
						|
            ::= { commandsTxEntry 65 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcMuteOnPPSFail OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                onlyAtStartup(2),
 | 
						|
                afterFailDelayTime(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Select the behaviour if the external second pulse is not available."
 | 
						|
            ::= { commandsTxEntry 66 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcMuteOnReferenceFail OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                onlyAtStartup(2),
 | 
						|
                afterFailDelayTime(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Select the behaviour if the external reference is not available."
 | 
						|
            ::= { commandsTxEntry 67 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRefFailDelayTime OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..24)
 | 
						|
            UNITS "Hours"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the time after the RF will be muted in case of a reference problem.
 | 
						|
                Zero hours means react immediately."
 | 
						|
            ::= { commandsTxEntry 68 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTypeLossOfInput OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                warning(1),
 | 
						|
                fault(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If the input signal is lost, either a warning or a fault can be generated.
 | 
						|
                If you select fault here, a switchover to the reserve exciter will be executed 
 | 
						|
                when input signal is lost."
 | 
						|
            ::= { commandsTxEntry 69 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutput OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Turns on/switches off the output signal. This switch takes the same effect as the switch on the frontpanel of the exciter."
 | 
						|
            ::= { commandsTxEntry 70 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutputRegulation OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Turns on/switches off the automatic output level regulation."
 | 
						|
            ::= { commandsTxEntry 71 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutputManualRfLevel OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the RF level (0.0 ... 100.0). The value relates to an attenuation of 0 dB."
 | 
						|
            ::= { commandsTxEntry 72 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutputAttenuation OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..9)
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Activates internal attenuators to reduce the output level of the exciter.
 | 
						|
                Adjustable in steps of 3 dB only."
 | 
						|
            ::= { commandsTxEntry 73 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutputRfSlope OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts a slope in the RF signal (-50.0 ... 50.0)."
 | 
						|
            ::= { commandsTxEntry 74 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfOutputModulationSlope OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Modulation slope (-50.0 ... 50.0)."
 | 
						|
            ::= { commandsTxEntry 75 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustStart OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                break(1),
 | 
						|
                start(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Starts the automatic IQ adjustment. It works for the current used local 1 frequency and lasts up to 5 minutes. In this time the output will be muted. During the adjustment no transmitter parameter shall be changed. Break will stop the automatic immediately. The IQ modulator looses its adjustment!
 | 
						|
                Read values mean idle(1) and started(2)."
 | 
						|
            ::= { commandsTxEntry 77 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustTestsignal OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Generates a test signal to adjust the IQ modulation. It is necessary to disconnect the rf-cable to the output stages."
 | 
						|
            ::= { commandsTxEntry 78 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustBiasCoarseI OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (-1023..1023)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the offset for I in huge steps."
 | 
						|
            ::= { commandsTxEntry 79 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustBiasCoarseQ OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (-1023..1023)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the offset for Q in huge steps."
 | 
						|
            ::= { commandsTxEntry 80 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustBiasFineI OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (-32767..32767)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the offset for I in small steps."
 | 
						|
            ::= { commandsTxEntry 81 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustBiasFineQ OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (-32767..32767)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the offset for Q in small steps."
 | 
						|
            ::= { commandsTxEntry 82 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustGainI OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..255)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the gain for I in small steps."
 | 
						|
            ::= { commandsTxEntry 83 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustGainQ OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..255)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the gain for Q in small steps."
 | 
						|
            ::= { commandsTxEntry 84 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfIqAdjustPhase OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the phase between I and Q (-14.000 ... 14.000)."
 | 
						|
            ::= { commandsTxEntry 85 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInput1Source OBJECT-TYPE
 | 
						|
            SYNTAX InputSource
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Source for input 1."
 | 
						|
            ::= { commandsTxEntry 86 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInput2Source OBJECT-TYPE
 | 
						|
            SYNTAX InputSource
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Source for input 2."
 | 
						|
            ::= { commandsTxEntry 87 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInpAutoReadyAfterChangeOv OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Input automatic ready after change over."
 | 
						|
            ::= { commandsTxEntry 88 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcInputFailDelayTime OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..600)
 | 
						|
            UNITS "Seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The time between detecting a loss of input signal and displaying a failure."
 | 
						|
            ::= { commandsTxEntry 89 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTransmitterType OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                atv(1),
 | 
						|
                dvb(2),
 | 
						|
                atsc(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "the TV standard of the transmitter
 | 
						|
                The transmitter is rebooted automatically when the TV standard is
 | 
						|
                changed. Signal processing is also switched over."
 | 
						|
            ::= { commandsTxEntry 90 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTimeScheduler OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If on, the time scheduler controls the tx type. When switching on the scheduler 
 | 
						|
                it may instantly set the correct TV standard and reboot the device."
 | 
						|
            ::= { commandsTxEntry 91 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcMuteCondition OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                onAllFaults(1),
 | 
						|
                notBeforeSyncLoss(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "When notBeforeSyncLoss(2) is selected,
 | 
						|
                it relativizes the cmdExcInputMuteOnFail setting mute(1):
 | 
						|
                If a DVB receiver is the last valid input, an existing transport stream,
 | 
						|
                even if it is faulty shall not be muted.
 | 
						|
                
 | 
						|
                Only for SLx/Sx801"
 | 
						|
            ::= { commandsTxEntry 92 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Warning limit for the RF control.
 | 
						|
                min: -15.0, max: 0.0"
 | 
						|
            ::= { commandsTxEntry 97 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcRfFailLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Fault limit for the RF control.
 | 
						|
                min: -15.0, max: 0.0"
 | 
						|
            ::= { commandsTxEntry 98 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcOutputPower OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "amplifier output power
 | 
						|
                0 ... 400 W"
 | 
						|
            ::= { commandsTxEntry 99 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdOstRefVoltageVision OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This adjusts the output power of the amplifier.
 | 
						|
                This value is settable with maximal 1 position after point (example 11.2)."
 | 
						|
            ::= { commandsTxEntry 100 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdOstMaxOutletTempThreshold OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (45..65)
 | 
						|
            UNITS "Degree Celsius"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the threshold for the outlet temperature."
 | 
						|
            ::= { commandsTxEntry 101 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcMonitoringOutput OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                reference10MHz(2),
 | 
						|
                generated1PPS(3),
 | 
						|
                kHz1(4),
 | 
						|
                pulse1PPS(5)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Selects which signal appears at the monitoring output."
 | 
						|
            ::= { commandsTxEntry 110 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcOcxoAdjust OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..65535)
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Adjusts the frequency of the internal 10 MHz reference.
 | 
						|
                This value only takes effect if the reference source 'internal' is selected."
 | 
						|
            ::= { commandsTxEntry 111 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcExpectInputReserve OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If on(1) the warning txExcInputReseveMissing will be generated
 | 
						|
                in case second input is missing."
 | 
						|
            ::= { commandsTxEntry 112 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcEnablePcrReset OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables/disables daily PCR resets.
 | 
						|
                This option is valid only in MFN operation.
 | 
						|
                The reset time is given in cmdExcTimeForDailyPcrReset."
 | 
						|
            ::= { commandsTxEntry 113 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcTimeForDailyPcrReset OBJECT-TYPE
 | 
						|
            SYNTAX TimeOfDay
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "Sets the time of day for daily PCR reset."
 | 
						|
            ::= { commandsTxEntry 114 }
 | 
						|
 | 
						|
        
 | 
						|
        cmdExcFailDelayMode OBJECT-TYPE
 | 
						|
            SYNTAX FailDelayMode
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Condition when the fail delay time is used."
 | 
						|
            ::= { commandsTxEntry 115 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryInfo OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 2 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryFaultTx OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary fault of the transmitter.
 | 
						|
                   true(1)  --> summary fault
 | 
						|
                   false(2) --> no summary fault
 | 
						|
                
 | 
						|
                There is a fault of at least one module (e.g. Exciter) which causes this summary fault.
 | 
						|
                
 | 
						|
                An equivalent would be the LED Fault at the transmitters frontpanel."
 | 
						|
            ::= { summaryInfo 1 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryWarningTx OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary warning of the transmitter.
 | 
						|
                   true(1)  --> summary warning
 | 
						|
                   false(2) --> no summary warning
 | 
						|
                
 | 
						|
                There is a fault of at least one module (e.g. Exciter) which causes this summary warning.
 | 
						|
                
 | 
						|
                An equivalent would be the LED Warning at the transmitters frontpanel."
 | 
						|
            ::= { summaryInfo 2 }
 | 
						|
 | 
						|
        
 | 
						|
        localModeTx OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates the local/remote-mode of the transmitter.
 | 
						|
                   true(1)  --> local
 | 
						|
                   false(2) --> remote
 | 
						|
                
 | 
						|
                The transmitter is eigther in local-mode or in remote-mode. 
 | 
						|
                For security reasons it is not possible to set this value!
 | 
						|
                
 | 
						|
                An equivalent would the LED Local at the transmitters frontpanel."
 | 
						|
            ::= { summaryInfo 3 }
 | 
						|
 | 
						|
        
 | 
						|
        rfOnTx OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The RF is present for the corresponding transmitter."
 | 
						|
            ::= { summaryInfo 4 }
 | 
						|
 | 
						|
        
 | 
						|
        forwardPower OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured forwarded power [W] of the transmitter. 
 | 
						|
                For Active Reserve systems it is the sum of both outputstages."
 | 
						|
            ::= { summaryInfo 5 }
 | 
						|
 | 
						|
        
 | 
						|
        reflectedPower OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured reflected power [W] of the transmitter. 
 | 
						|
                For Active Reserve systems it is the sum of both outputstages.
 | 
						|
                
 | 
						|
                Not available for lowpower systems."
 | 
						|
            ::= { summaryInfo 6 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryFaultExcA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary fault of exciter."
 | 
						|
            ::= { summaryInfo 7 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryFaultOstA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary fault of outputstage."
 | 
						|
            ::= { summaryInfo 8 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryFaultExcB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary fault of exciter."
 | 
						|
            ::= { summaryInfo 9 }
 | 
						|
 | 
						|
        
 | 
						|
        summaryFaultOstB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This indicates a summary fault of outputstage."
 | 
						|
            ::= { summaryInfo 10 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterAutomaticReady OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Exciter Automatic is Ready. 
 | 
						|
                In case of any fault on one exciter, there will be a switchover to the other exciter."
 | 
						|
            ::= { summaryInfo 11 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterAutomaticChanged OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Exciter Automatic has changed. 
 | 
						|
                There was a fault on one exciter which lead to this changeover."
 | 
						|
            ::= { summaryInfo 12 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterAutomaticFault OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Exciter Automatic is faulty. 
 | 
						|
                In case of any fault on one exciter, there will be no switchover to the other exciter,
 | 
						|
                because of this fault."
 | 
						|
            ::= { summaryInfo 13 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageAutomaticReady OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Outputstage Automatic is Ready. 
 | 
						|
                In case of any fault on one outputstage, there will be a switchover to the other outputstage.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { summaryInfo 14 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageAutomaticChanged OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Outputstage Automatic has changed. 
 | 
						|
                There was a fault on one outputstage which lead to this changeover.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { summaryInfo 15 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageAutomaticFault OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Outputstage Automatic is faulty. 
 | 
						|
                In case of any fault on one outputstage, there will be no switchover to the other outputstage,
 | 
						|
                because of this fault.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { summaryInfo 16 }
 | 
						|
 | 
						|
        
 | 
						|
        noConnectionExcA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "No Connection between NetCCU and Exciter."
 | 
						|
            ::= { summaryInfo 17 }
 | 
						|
 | 
						|
        
 | 
						|
        noConnectionOstA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "No Connection between NetCCU and Outputstage."
 | 
						|
            ::= { summaryInfo 18 }
 | 
						|
 | 
						|
        
 | 
						|
        noConnectionExcB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "No Connection between NetCCU and Exciter."
 | 
						|
            ::= { summaryInfo 19 }
 | 
						|
 | 
						|
        
 | 
						|
        noConnectionOstB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "No Connection between NetCCU and Outputstage."
 | 
						|
            ::= { summaryInfo 20 }
 | 
						|
 | 
						|
        
 | 
						|
        activeExcA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "ExciterA is currently active."
 | 
						|
            ::= { summaryInfo 21 }
 | 
						|
 | 
						|
        
 | 
						|
        activeOstA OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "OutputstageA is currently active."
 | 
						|
            ::= { summaryInfo 22 }
 | 
						|
 | 
						|
        
 | 
						|
        activeExcB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "ExciterB is currently active."
 | 
						|
            ::= { summaryInfo 23 }
 | 
						|
 | 
						|
        
 | 
						|
        activeOstB OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "OutputstageB is currently active."
 | 
						|
            ::= { summaryInfo 24 }
 | 
						|
 | 
						|
        
 | 
						|
        forwardPowerOstA OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured forwarded power [W] of the OutputstageA."
 | 
						|
            ::= { summaryInfo 25 }
 | 
						|
 | 
						|
        
 | 
						|
        reflectedPowerOstA OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured reflected power [W] of the OutputstageA.
 | 
						|
                
 | 
						|
                Not available for lowpower systems."
 | 
						|
            ::= { summaryInfo 26 }
 | 
						|
 | 
						|
        
 | 
						|
        forwardPowerOstB OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured forwarded power [W] of the OutputstageB."
 | 
						|
            ::= { summaryInfo 27 }
 | 
						|
 | 
						|
        
 | 
						|
        reflectedPowerOstB OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured reflected power [W] of the OutputstageB.
 | 
						|
                
 | 
						|
                Not available for lowpower systems."
 | 
						|
            ::= { summaryInfo 28 }
 | 
						|
 | 
						|
        
 | 
						|
        powerSupply OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Monitoring value of the output voltages of the power supply."
 | 
						|
            ::= { summaryInfo 29 }
 | 
						|
 | 
						|
        
 | 
						|
        additionalPowerSupply OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows whether the NetCCU has an additional (external) power supply."
 | 
						|
            ::= { summaryInfo 30 }
 | 
						|
 | 
						|
        
 | 
						|
        internalPowerSupply OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Monitoring value of the output voltages of the internal power supply."
 | 
						|
            ::= { summaryInfo 31 }
 | 
						|
 | 
						|
        
 | 
						|
        externalPowerSupply OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Monitoring value of the output voltages of the external power supply."
 | 
						|
            ::= { summaryInfo 32 }
 | 
						|
 | 
						|
        
 | 
						|
        detailedInfo OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ExcInputEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A table for more detailed information about the exciter.
 | 
						|
                These values are all read-only. For settings, refer to commands."
 | 
						|
            ::= { detailedInfo 2 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputEntry OBJECT-TYPE
 | 
						|
            SYNTAX ExcInputEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for a designated input channel."
 | 
						|
            INDEX { excInputExcIdx, excInputChannelIdx }
 | 
						|
            ::= { excInputTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ExcInputEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                excInputExcIdx
 | 
						|
                    IndexAB,
 | 
						|
                excInputChannelIdx
 | 
						|
                    Integer32,
 | 
						|
                excInputChannelName
 | 
						|
                    INTEGER,
 | 
						|
                excInputConnected
 | 
						|
                    TruthValue,
 | 
						|
                excInputSeamless
 | 
						|
                    TruthValue,
 | 
						|
                excInputPreselected
 | 
						|
                    TruthValue,
 | 
						|
                excInputActive
 | 
						|
                    TruthValue,
 | 
						|
                excInputMipFail
 | 
						|
                    TruthValue,
 | 
						|
                excInputBandwidth
 | 
						|
                    INTEGER,
 | 
						|
                excInputFFTLength
 | 
						|
                    INTEGER,
 | 
						|
                excInputGuardInterval
 | 
						|
                    INTEGER,
 | 
						|
                excInputConstellation
 | 
						|
                    INTEGER,
 | 
						|
                excInputAlpha
 | 
						|
                    INTEGER,
 | 
						|
                excInputCellID
 | 
						|
                    Integer32,
 | 
						|
                excInputInterleaver
 | 
						|
                    INTEGER,
 | 
						|
                excInputCodeRate
 | 
						|
                    INTEGER,
 | 
						|
                excInputPacketLength
 | 
						|
                    Integer32,
 | 
						|
                excInputMeasuredDatarate
 | 
						|
                    Integer32,
 | 
						|
                excInputRequiredDatarate
 | 
						|
                    Integer32,
 | 
						|
                excInputMaximumDelay
 | 
						|
                    Integer32
 | 
						|
             }
 | 
						|
 | 
						|
        excInputExcIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index for exciterA (and exciterB if there are DualDrive systems)."
 | 
						|
            ::= { excInputEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputChannelIdx OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..6)
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index for the different input channels."
 | 
						|
            ::= { excInputEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputChannelName OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                hp1(1),
 | 
						|
                hp2(2),
 | 
						|
                lp1(3),
 | 
						|
                lp2(4),
 | 
						|
                activeHP(5),
 | 
						|
                activeLP(6)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the logical name for the index for the different input channels."
 | 
						|
            ::= { excInputEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputConnected OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input channel is connected."
 | 
						|
            ::= { excInputEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputSeamless OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input channel is in seamless mode."
 | 
						|
            ::= { excInputEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputPreselected OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input channel is the preselected."
 | 
						|
            ::= { excInputEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputActive OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input channel is active."
 | 
						|
            ::= { excInputEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputMipFail OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Input channel MIP fail."
 | 
						|
            ::= { excInputEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputBandwidth OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                mhz5(1),
 | 
						|
                mhz6(2),
 | 
						|
                mhz7(3),
 | 
						|
                mhz8(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The bandwidth used by the input channel."
 | 
						|
            ::= { excInputEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputFFTLength OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                k2(1),
 | 
						|
                k8(2),
 | 
						|
                k4(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The used FFT length (depends on the DVB network)."
 | 
						|
            ::= { excInputEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputGuardInterval OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                oneOf32(1),
 | 
						|
                oneOf16(2),
 | 
						|
                oneOf8(3),
 | 
						|
                oneOf4(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Guard interval affects the error correction in multipath receiving situations.
 | 
						|
                A long Guard Interval reduces the amount of payload data."
 | 
						|
            ::= { excInputEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputConstellation OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                qpsk(1),
 | 
						|
                qam16(2),
 | 
						|
                qam64(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This parameter sets the modulation mode."
 | 
						|
            ::= { excInputEntry 12 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputAlpha OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                noHierarchy(1),
 | 
						|
                one(2),
 | 
						|
                two(3),
 | 
						|
                four(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "An alpha greater than zero enables the hierarchical coding mode."
 | 
						|
            ::= { excInputEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputCellID OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..65535)
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Via Cell ID the receiver knows the current network."
 | 
						|
            ::= { excInputEntry 14 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputInterleaver OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                indepth(1),
 | 
						|
                nat(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables the bit interleaver for hierarchical coding"
 | 
						|
            ::= { excInputEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputCodeRate OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                oneOf2(1),
 | 
						|
                twoOf3(2),
 | 
						|
                threeOf4(3),
 | 
						|
                fiveOf6(4),
 | 
						|
                sevenOf8(5)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Coderate can be set separately for HP and LP channel."
 | 
						|
            ::= { excInputEntry 16 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputPacketLength OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (188..208)
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Packet length for the channel."
 | 
						|
            ::= { excInputEntry 17 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputMeasuredDatarate OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured datarate of the input."
 | 
						|
            ::= { excInputEntry 18 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputRequiredDatarate OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The required datarate of the input."
 | 
						|
            ::= { excInputEntry 19 }
 | 
						|
 | 
						|
        
 | 
						|
        excInputMaximumDelay OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..100000000)
 | 
						|
            UNITS "Nanoseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Period of time between the signal leaving the play-out center (MIP inserter)
 | 
						|
                and its regular transmission at the antenna.
 | 
						|
                This delay is set in the MIP inserter and serves as a basis
 | 
						|
                for all the transmitters in the SFN."
 | 
						|
            ::= { excInputEntry 20 }
 | 
						|
 | 
						|
        
 | 
						|
        ostTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF OstEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The table of racks."
 | 
						|
            ::= { detailedInfo 3 }
 | 
						|
 | 
						|
        
 | 
						|
        ostEntry OBJECT-TYPE
 | 
						|
            SYNTAX OstEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A row (an entry) for one rack."
 | 
						|
            INDEX { ostIdx, ostRackIdx, ostRackAmpIdx }
 | 
						|
            ::= { ostTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        OstEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                ostIdx
 | 
						|
                    IndexAB,
 | 
						|
                ostRackIdx
 | 
						|
                    IndexRack,
 | 
						|
                ostRackInletTemperature
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackOutletTemperature
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAuxPowerSupply
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpIdx
 | 
						|
                    IndexAmplifier,
 | 
						|
                ostRackAmpI1A
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI2A
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI3A
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI4A
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI1B
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI2B
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI3B
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpI4B
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpIDrv
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpUDc
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpIDc
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpUDcControl
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpUReg
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpPowerA
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpPowerB
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpPowerOut
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpPowerReflection
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpPowerReference
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpDeltaPhase
 | 
						|
                    FloatingPoint,
 | 
						|
                ostRackAmpCmdDeltaPhase
 | 
						|
                    FloatingPoint
 | 
						|
             }
 | 
						|
 | 
						|
        ostIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The dedicated outputstage (A/B)."
 | 
						|
            ::= { ostEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexRack
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The rack number (1..10)."
 | 
						|
            ::= { ostEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackInletTemperature OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Degree Celsius"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The inlet temperature."
 | 
						|
            ::= { ostEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackOutletTemperature OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Degree Celsius"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The outlet temperature."
 | 
						|
            ::= { ostEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAuxPowerSupply OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Control voltage of auxiliary power supply of the designated rack.
 | 
						|
                The value should be between 11.1 to 13.2 V."
 | 
						|
            ::= { ostEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAmplifier
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Amplifier Index"
 | 
						|
            ::= { ostEntry 400 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI1A OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_1A)."
 | 
						|
            ::= { ostEntry 401 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI2A OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_2A)."
 | 
						|
            ::= { ostEntry 402 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI3A OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_3A)."
 | 
						|
            ::= { ostEntry 403 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI4A OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_4A)."
 | 
						|
            ::= { ostEntry 404 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI1B OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_1B)."
 | 
						|
            ::= { ostEntry 405 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI2B OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_2B)."
 | 
						|
            ::= { ostEntry 406 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI3B OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_3B)."
 | 
						|
            ::= { ostEntry 407 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpI4B OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier module current (I_4B)."
 | 
						|
            ::= { ostEntry 408 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpIDrv OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The driver module current (I_DRV)."
 | 
						|
            ::= { ostEntry 409 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpUDc OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier supply voltage."
 | 
						|
            ::= { ostEntry 410 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpIDc OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier supply current."
 | 
						|
            ::= { ostEntry 411 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpUDcControl OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power supply control voltage."
 | 
						|
            ::= { ostEntry 412 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpUReg OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power amplifier AGC voltage."
 | 
						|
            ::= { ostEntry 413 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpPowerA OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage power detector A."
 | 
						|
            ::= { ostEntry 414 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpPowerB OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage power detector B."
 | 
						|
            ::= { ostEntry 415 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpPowerOut OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage forward power detector."
 | 
						|
            ::= { ostEntry 416 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpPowerReflection OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage reflected power detector."
 | 
						|
            ::= { ostEntry 417 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpPowerReference OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The reference voltage for output power."
 | 
						|
            ::= { ostEntry 418 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpDeltaPhase OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The measured phase delta for output power."
 | 
						|
            ::= { ostEntry 419 }
 | 
						|
 | 
						|
        
 | 
						|
        ostRackAmpCmdDeltaPhase OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The phase delta setting for output power.
 | 
						|
                The range is -50.0% to 50.0%."
 | 
						|
            ::= { ostEntry 420 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterStatusTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ExciterStatusEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Exciter status values."
 | 
						|
            ::= { detailedInfo 20 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterStatusEntry OBJECT-TYPE
 | 
						|
            SYNTAX ExciterStatusEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A row (an entry) for one exciter."
 | 
						|
            INDEX { excStatusExcIdx }
 | 
						|
            ::= { exciterStatusTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ExciterStatusEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                excStatusExcIdx
 | 
						|
                    IndexAB,
 | 
						|
                excStatusRfOutputAgcRegulation
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusRfIqAdjustAuto
 | 
						|
                    INTEGER,
 | 
						|
                excStatusRfIqAdjustLO1Frequency
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusNominalPower
 | 
						|
                    Integer32,
 | 
						|
                excStatusVSWR
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayProcessing
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayDynamic
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayNetwork
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayTxOffset
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayMaximum
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusSfnDelayTotal
 | 
						|
                    FloatingPoint,
 | 
						|
                excStatusAmplifierControl
 | 
						|
                    INTEGER,
 | 
						|
                excStatusReqDataRateHP
 | 
						|
                    Integer32,
 | 
						|
                excStatusReqDataRateLP
 | 
						|
                    Integer32,
 | 
						|
                excStatusFailDelay
 | 
						|
                    FailDelayStatus
 | 
						|
             }
 | 
						|
 | 
						|
        excStatusExcIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The dedicated exciter (A/B)."
 | 
						|
            ::= { exciterStatusEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusRfOutputAgcRegulation OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the operating point of the RF regulator. The shown value should be around 50 per cent."
 | 
						|
            ::= { exciterStatusEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusRfIqAdjustAuto OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                notAdjusted(1),
 | 
						|
                inProgress(2),
 | 
						|
                adjusted(3)
 | 
						|
                }
 | 
						|
            UNITS "Percent"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Automatic I/Q-Adjust."
 | 
						|
            ::= { exciterStatusEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusRfIqAdjustLO1Frequency OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "MHz"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Modulator LO1."
 | 
						|
            ::= { exciterStatusEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusNominalPower OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Description."
 | 
						|
            ::= { exciterStatusEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusVSWR OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Voltage Standing Wave Ratio"
 | 
						|
            ::= { exciterStatusEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayProcessing OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Minimum signal transmit time through the exciter.
 | 
						|
                This delay depends on the DVB transmission parameters."
 | 
						|
            ::= { exciterStatusEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayDynamic OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The period of time by which signal processing is artificially delayed
 | 
						|
                so that the desired time of transmission is obtained."
 | 
						|
            ::= { exciterStatusEntry 14 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayNetwork OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The signal propagation time between the play-out center
 | 
						|
                (MIP inserter) and the exciter input. This delay depends
 | 
						|
                on the transmission path used."
 | 
						|
            ::= { exciterStatusEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayTxOffset OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An individual transmitter specific delay. It can be adjusted
 | 
						|
                via data carousel of the SFN adapter. It is true for a
 | 
						|
                specific transmitter address."
 | 
						|
            ::= { exciterStatusEntry 16 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayMaximum OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The period of time between the signal leaving the play-out center
 | 
						|
                (MIP inserter) and its regular transmission at the antenna.
 | 
						|
                This delay is set in the MIP inserter and serves as a basis for
 | 
						|
                all the transmitters in the SFN."
 | 
						|
            ::= { exciterStatusEntry 17 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusSfnDelayTotal OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Microseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The actual signal transit time through the exciter.
 | 
						|
                This is derived from the sum of static-, dynamic-, 
 | 
						|
                offset- and processing delay."
 | 
						|
            ::= { exciterStatusEntry 18 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusAmplifierControl OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                on(1),
 | 
						|
                off(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Amplifier control status"
 | 
						|
            ::= { exciterStatusEntry 20 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusReqDataRateHP OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            UNITS "bit per seconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Required data rate on HP input
 | 
						|
                with respect to the current TPS settings."
 | 
						|
            ::= { exciterStatusEntry 30 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusReqDataRateLP OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            UNITS "bit per seconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Required data rate on LP input
 | 
						|
                with respect to the current TPS settings."
 | 
						|
            ::= { exciterStatusEntry 31 }
 | 
						|
 | 
						|
        
 | 
						|
        excStatusFailDelay OBJECT-TYPE
 | 
						|
            SYNTAX FailDelayStatus
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows whether the fail delay time is qualified."
 | 
						|
            ::= { exciterStatusEntry 40 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterPrecorrectionTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ExciterPrecorrectionEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Exciter status values."
 | 
						|
            ::= { detailedInfo 21 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterPrecorrectionEntry OBJECT-TYPE
 | 
						|
            SYNTAX ExciterPrecorrectionEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A row (an entry) for one exciter."
 | 
						|
            INDEX { excPrecExcIdx }
 | 
						|
            ::= { exciterPrecorrectionTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ExciterPrecorrectionEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                excPrecExcIdx
 | 
						|
                    IndexAB,
 | 
						|
                excPrecLinCorrection
 | 
						|
                    SwitchOnOff,
 | 
						|
                excPrecLinAutomaticADE
 | 
						|
                    INTEGER,
 | 
						|
                excPrecLinMaxAmplitudeRipple
 | 
						|
                    FloatingPoint,
 | 
						|
                excPrecLinMaxGroupDelayRipple
 | 
						|
                    Integer32,
 | 
						|
                excPrecLinAmplitudeRipple
 | 
						|
                    FloatingPoint,
 | 
						|
                excPrecLinGroupDelayRipple
 | 
						|
                    Integer32,
 | 
						|
                excPrecLinInputLevel
 | 
						|
                    INTEGER,
 | 
						|
                excPrecLinAutomatic
 | 
						|
                    INTEGER,
 | 
						|
                excPrecNonlinCorrection
 | 
						|
                    SwitchOnOff,
 | 
						|
                excPrecNonlinAutomaticADE
 | 
						|
                    INTEGER,
 | 
						|
                excPrecNonlinThresholdShoulders
 | 
						|
                    FloatingPoint,
 | 
						|
                excPrecNonlinShoulderLeft
 | 
						|
                    FloatingPoint,
 | 
						|
                excPrecNonlinShoulderRight
 | 
						|
                    FloatingPoint,
 | 
						|
                excPrecNonlinInputLevel
 | 
						|
                    INTEGER,
 | 
						|
                excPrecNonlinAutomatic
 | 
						|
                    INTEGER,
 | 
						|
                excPrecUserState
 | 
						|
                    EqualizerCalibrationState,
 | 
						|
                excPrecFactoryState
 | 
						|
                    EqualizerCalibrationState,
 | 
						|
                excPrecRestoreCurrentSettings
 | 
						|
                    INTEGER,
 | 
						|
                excPrecRestoreAllSettings
 | 
						|
                    INTEGER
 | 
						|
             }
 | 
						|
 | 
						|
        excPrecExcIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The dedicated exciter (A/B)."
 | 
						|
            ::= { exciterPrecorrectionEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinCorrection OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Switches on/turns off the linear precorrector."
 | 
						|
            ::= { exciterPrecorrectionEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinAutomaticADE OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                manual(1),
 | 
						|
                automatic(2),
 | 
						|
                adaptive(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables /disables the automatic precorrector. To get the ADE in work linear precorrection has to be switched on."
 | 
						|
            ::= { exciterPrecorrectionEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinMaxAmplitudeRipple OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Sets te maximum ripple for automatic amplitude correction (0.0 ... 2.0)."
 | 
						|
            ::= { exciterPrecorrectionEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinMaxGroupDelayRipple OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..500)
 | 
						|
            UNITS "Nanoseconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Sets the maximum ripple for automatic group delay correction."
 | 
						|
            ::= { exciterPrecorrectionEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinAmplitudeRipple OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the current amplitude ripple."
 | 
						|
            ::= { exciterPrecorrectionEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinGroupDelayRipple OBJECT-TYPE
 | 
						|
            SYNTAX Integer32
 | 
						|
            UNITS "Nanoseconds"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the current group delay ripple."
 | 
						|
            ::= { exciterPrecorrectionEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinInputLevel OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                tooHigh(1),
 | 
						|
                ok(2),
 | 
						|
                tooLow(3),
 | 
						|
                failure(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the state of the feedback signal from the measurement point between output stage and antenna."
 | 
						|
            ::= { exciterPrecorrectionEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecLinAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                disabled(1),
 | 
						|
                active(2),
 | 
						|
                calculate(3),
 | 
						|
                measure(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows if the automatic precorrector works properly."
 | 
						|
            ::= { exciterPrecorrectionEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinCorrection OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Switches on/turns off the nonlinear precorrector."
 | 
						|
            ::= { exciterPrecorrectionEntry 12 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinAutomaticADE OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                manual(1),
 | 
						|
                automatic(2),
 | 
						|
                adaptive(3)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Enables /disables the automatic precorrector. To get the ADE in work nonlinear precorrection has to be switched on."
 | 
						|
            ::= { exciterPrecorrectionEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinThresholdShoulders OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The target shoulder distance for ADE (0.0 ... 40.0)."
 | 
						|
            ::= { exciterPrecorrectionEntry 14 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinShoulderLeft OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Displays the current measurement for the left handed shoulder distance."
 | 
						|
            ::= { exciterPrecorrectionEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinShoulderRight OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Displays the current measurement of the right handed shoulder."
 | 
						|
            ::= { exciterPrecorrectionEntry 16 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinInputLevel OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                tooHigh(1),
 | 
						|
                ok(2),
 | 
						|
                tooLow(3),
 | 
						|
                failure(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the state of the feedback signal from the measurement point between output stage and antenna."
 | 
						|
            ::= { exciterPrecorrectionEntry 17 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecNonlinAutomatic OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                disabled(1),
 | 
						|
                active(2),
 | 
						|
                calculate(3),
 | 
						|
                measure(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows if the automatic precorrector works properly."
 | 
						|
            ::= { exciterPrecorrectionEntry 18 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecUserState OBJECT-TYPE
 | 
						|
            SYNTAX EqualizerCalibrationState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "status of the user precorrection settings"
 | 
						|
            ::= { exciterPrecorrectionEntry 100 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecFactoryState OBJECT-TYPE
 | 
						|
            SYNTAX EqualizerCalibrationState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "status of the factory precorrection settings"
 | 
						|
            ::= { exciterPrecorrectionEntry 101 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecRestoreCurrentSettings OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                stop(1),
 | 
						|
                start(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "restores current factory precorrection setting"
 | 
						|
            ::= { exciterPrecorrectionEntry 102 }
 | 
						|
 | 
						|
        
 | 
						|
        excPrecRestoreAllSettings OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                stop(1),
 | 
						|
                start(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "restores all factory precorrection settings"
 | 
						|
            ::= { exciterPrecorrectionEntry 103 }
 | 
						|
 | 
						|
        
 | 
						|
        configurationTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ConfigurationEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Table for Type Configuration parameters."
 | 
						|
            ::= { detailedInfo 30 }
 | 
						|
 | 
						|
        
 | 
						|
        configurationEntry OBJECT-TYPE
 | 
						|
            SYNTAX ConfigurationEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for the Type Configuration parameters."
 | 
						|
            INDEX { configTvStandardIdx }
 | 
						|
            ::= { configurationTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ConfigurationEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                configTvStandardIdx
 | 
						|
                    TvStandard,
 | 
						|
                configTvStandardName
 | 
						|
                    TvStandard,
 | 
						|
                configRxFrequency
 | 
						|
                    Integer32,
 | 
						|
                configFrequency
 | 
						|
                    Integer32,
 | 
						|
                configPower
 | 
						|
                    FloatingPoint,
 | 
						|
                configInputSource
 | 
						|
                    InputSource
 | 
						|
             }
 | 
						|
 | 
						|
        configTvStandardIdx OBJECT-TYPE
 | 
						|
            SYNTAX TvStandard
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index for the TV standard."
 | 
						|
            ::= { configurationEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        configTvStandardName OBJECT-TYPE
 | 
						|
            SYNTAX TvStandard
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The name of the TV standard as a text."
 | 
						|
            ::= { configurationEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        configRxFrequency OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (160000000..910000000)
 | 
						|
            UNITS "Hz"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input frequency for input 1."
 | 
						|
            ::= { configurationEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        configFrequency OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (47000000..1500000000)
 | 
						|
            UNITS "Hz"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The output frequency for input 1."
 | 
						|
            ::= { configurationEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        configPower OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The output power (0.0 ... 2500.0)  for input 1."
 | 
						|
            ::= { configurationEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        configInputSource OBJECT-TYPE
 | 
						|
            SYNTAX InputSource
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The source for input 1."
 | 
						|
            ::= { configurationEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        timeSchedulerTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF TimeSchedulerEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Table for Time Scheduler parameters."
 | 
						|
            ::= { detailedInfo 31 }
 | 
						|
 | 
						|
        
 | 
						|
        timeSchedulerEntry OBJECT-TYPE
 | 
						|
            SYNTAX TimeSchedulerEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry in the table for the Time Scheduler parameters.
 | 
						|
                
 | 
						|
                A row in this table is created by setting the value of schedulerRowStatus to 
 | 
						|
                'createAndGo' or 'createAndWait'.
 | 
						|
                
 | 
						|
                A row in this table is deleted by setting the value of schedulerRowStatus to 
 | 
						|
                'destroy'."
 | 
						|
            INDEX { schedulerDateTimeIdx }
 | 
						|
            ::= { timeSchedulerTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        TimeSchedulerEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                schedulerDateTimeIdx
 | 
						|
                    DateAndTime,
 | 
						|
                schedulerRowStatus
 | 
						|
                    RowStatus,
 | 
						|
                schedulerEvent
 | 
						|
                    INTEGER,
 | 
						|
                schedulerDateTime
 | 
						|
                    DateAndTime,
 | 
						|
                schedulerTvStandard
 | 
						|
                    TvStandard
 | 
						|
             }
 | 
						|
 | 
						|
        schedulerDateTimeIdx OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The DateAndTime index.
 | 
						|
                
 | 
						|
                Note: Deci-seconds different from 0 and UTC values are ignored.
 | 
						|
                      The index is implemented as a Fixed length string of 8 components. The last
 | 
						|
                      component (Deci-seconds) is always 0.
 | 
						|
                Example:
 | 
						|
                      The DateTime of 2008-9-15,17:45:30.0 
 | 
						|
                      has the index: 7.216.9.15.17.45.30.0
 | 
						|
                "
 | 
						|
            ::= { timeSchedulerEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        schedulerRowStatus OBJECT-TYPE
 | 
						|
            SYNTAX RowStatus
 | 
						|
            MAX-ACCESS read-create
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This object is used to create and delete rows in the timeSchedulerTable."
 | 
						|
            ::= { timeSchedulerEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        schedulerEvent OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                daily(1),
 | 
						|
                once(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-create
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The event type."
 | 
						|
            ::= { timeSchedulerEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        schedulerDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The start date and the time of a daily or one-time event."
 | 
						|
            ::= { timeSchedulerEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        schedulerTvStandard OBJECT-TYPE
 | 
						|
            SYNTAX TvStandard
 | 
						|
            MAX-ACCESS read-create
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The TV standard."
 | 
						|
            ::= { timeSchedulerEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        configuration2Table OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF Configuration2Entry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Table for Type Configuration parameters of input 2."
 | 
						|
            ::= { detailedInfo 32 }
 | 
						|
 | 
						|
        
 | 
						|
        configuration2Entry OBJECT-TYPE
 | 
						|
            SYNTAX Configuration2Entry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for the Type Configuration parameters of input 2."
 | 
						|
            AUGMENTS { configurationEntry }
 | 
						|
            ::= { configuration2Table 1 }
 | 
						|
 | 
						|
        
 | 
						|
        Configuration2Entry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                config2TvStandardName
 | 
						|
                    TvStandard,
 | 
						|
                config2RxFrequency
 | 
						|
                    Integer32,
 | 
						|
                config2Frequency
 | 
						|
                    Integer32,
 | 
						|
                config2Power
 | 
						|
                    FloatingPoint,
 | 
						|
                config2InputSource
 | 
						|
                    InputSource
 | 
						|
             }
 | 
						|
 | 
						|
        config2TvStandardName OBJECT-TYPE
 | 
						|
            SYNTAX TvStandard
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The name of the TV standard as a text."
 | 
						|
            ::= { configuration2Entry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        config2RxFrequency OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (160000000..910000000)
 | 
						|
            UNITS "Hz"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The input frequency for input 2."
 | 
						|
            ::= { configuration2Entry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        config2Frequency OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (47000000..1500000000)
 | 
						|
            UNITS "Hz"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The output frequency for input 2."
 | 
						|
            ::= { configuration2Entry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        config2Power OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The output power (0.0 ... 2500.0)  for input 2."
 | 
						|
            ::= { configuration2Entry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        config2InputSource OBJECT-TYPE
 | 
						|
            SYNTAX InputSource
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The source for input 2."
 | 
						|
            ::= { configuration2Entry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        productInfoTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ProductInfoEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The table for product typeplates."
 | 
						|
            ::= { detailedInfo 100 }
 | 
						|
 | 
						|
        
 | 
						|
        productInfoEntry OBJECT-TYPE
 | 
						|
            SYNTAX ProductInfoEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A row (an entry) for one typeplate."
 | 
						|
            INDEX { prodInfoModuleIdx, prodInfoDeviceIdx, prodInfoRackIdx, prodInfoAmpIdx }
 | 
						|
            ::= { productInfoTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ProductInfoEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                prodInfoModuleIdx
 | 
						|
                    ProdInfoModuleNameTv,
 | 
						|
                prodInfoDeviceIdx
 | 
						|
                    IndexAB,
 | 
						|
                prodInfoRackIdx
 | 
						|
                    IndexRack,
 | 
						|
                prodInfoAmpIdx
 | 
						|
                    IndexAmplifier,
 | 
						|
                prodInfoModuleName
 | 
						|
                    ProdInfoModuleNameTv,
 | 
						|
                prodInfoSerialNumber
 | 
						|
                    ReadableString,
 | 
						|
                prodInfoIdentNumberSW
 | 
						|
                    ReadableString,
 | 
						|
                prodInfoVersionNumberSW
 | 
						|
                    ReadableString,
 | 
						|
                prodInfoIdentNumberHW
 | 
						|
                    ReadableString,
 | 
						|
                prodInfoVersionNumberHW
 | 
						|
                    ReadableString,
 | 
						|
                productInfoProductDateHW
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        prodInfoModuleIdx OBJECT-TYPE
 | 
						|
            SYNTAX ProdInfoModuleNameTv
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The module index."
 | 
						|
            ::= { productInfoEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoDeviceIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The dedicated device (A/B)."
 | 
						|
            ::= { productInfoEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoRackIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexRack
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The rack number (1..10)."
 | 
						|
            ::= { productInfoEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoAmpIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAmplifier
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Amplifier Index"
 | 
						|
            ::= { productInfoEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoModuleName OBJECT-TYPE
 | 
						|
            SYNTAX ProdInfoModuleNameTv
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The name of the module as a text."
 | 
						|
            ::= { productInfoEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoSerialNumber OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The serial number of the subdevice."
 | 
						|
            ::= { productInfoEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoIdentNumberSW OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Rohde&Schwarz identification number of the software, for example 2094.2090.02."
 | 
						|
            ::= { productInfoEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoVersionNumberSW OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Rohde&Schwarz revision number of the software, for example 1.2.1."
 | 
						|
            ::= { productInfoEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoIdentNumberHW OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU)."
 | 
						|
            ::= { productInfoEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        prodInfoVersionNumberHW OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03."
 | 
						|
            ::= { productInfoEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        productInfoProductDateHW OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The Rohde&Schwarz production date of the hardware,"
 | 
						|
            ::= { productInfoEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        logbook OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 4 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCUNumberOfEntries OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of entries in logbook."
 | 
						|
            ::= { logbook 1 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookClear OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Clear the logbook.
 | 
						|
                idle(1)    --> ready
 | 
						|
                clear(2)   --> do clear now
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { logbook 2 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF NetCCULogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "NetCCU logbook table."
 | 
						|
            ::= { logbook 3 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookEntry OBJECT-TYPE
 | 
						|
            SYNTAX NetCCULogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is a entry in the logbook."
 | 
						|
            INDEX { netCCULogbookEntryIdx }
 | 
						|
            ::= { netCCULogbookTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        NetCCULogbookEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                netCCULogbookEntryIdx
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                netCCULogbookEntryNbr
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                netCCULogbookType
 | 
						|
                    EventClass,
 | 
						|
                netCCULogbookSlope
 | 
						|
                    LogbookEntrySlope,
 | 
						|
                netCCULogbookMessage
 | 
						|
                    LogbookEntryMessagesNetCCU,
 | 
						|
                netCCULogbookDateTime
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        netCCULogbookEntryIdx OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is an increasing number from 1 to maximum. It is used as an index column for SNMP."
 | 
						|
            ::= { netCCULogbookEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookEntryNbr OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the number of the logbook entry. It is an decreasing number from maximum down to 1."
 | 
						|
            ::= { netCCULogbookEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookType OBJECT-TYPE
 | 
						|
            SYNTAX EventClass
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Can either be Fault, Warning or State."
 | 
						|
            ::= { netCCULogbookEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookSlope OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntrySlope
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Either set (event raises) or reset (event disappears)"
 | 
						|
            ::= { netCCULogbookEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookMessage OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntryMessagesNetCCU
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See RS-XX8000-COMMON-MIB - TextualConvention - LogbookEntryMessagesNetCCU for details."
 | 
						|
            ::= { netCCULogbookEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        netCCULogbookDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "netCCULogbookDateTime"
 | 
						|
            ::= { netCCULogbookEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterANumberOfEntries OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of entries in logbook."
 | 
						|
            ::= { logbook 4 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterALogbookClear OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Clear the logbook.
 | 
						|
                idle(1)    --> ready
 | 
						|
                clear(2)   --> do clear now
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { logbook 5 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterALogbookTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ExciterALogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "ExciterA logbook table."
 | 
						|
            ::= { logbook 6 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterALogbookEntry OBJECT-TYPE
 | 
						|
            SYNTAX ExciterALogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is a entry in the logbook."
 | 
						|
            INDEX { excALogbookEntryIdx }
 | 
						|
            ::= { exciterALogbookTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ExciterALogbookEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                excALogbookEntryIdx
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                excALogbookEntryNbr
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                excALogbookType
 | 
						|
                    EventClass,
 | 
						|
                excALogbookSlope
 | 
						|
                    LogbookEntrySlope,
 | 
						|
                excALogbookMessage
 | 
						|
                    LogbookEntryMessagesExcTv,
 | 
						|
                excALogbookDateTime
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        excALogbookEntryIdx OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is an increasing number from 1 to maximum. It is used as an index column for SNMP."
 | 
						|
            ::= { exciterALogbookEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        excALogbookEntryNbr OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the number of the logbook entry. It is an decreasing number from maximum down to 1."
 | 
						|
            ::= { exciterALogbookEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        excALogbookType OBJECT-TYPE
 | 
						|
            SYNTAX EventClass
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Can either be Fault, Warning or State."
 | 
						|
            ::= { exciterALogbookEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excALogbookSlope OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntrySlope
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Either set (event raises) or reset (event disappears)"
 | 
						|
            ::= { exciterALogbookEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        excALogbookMessage OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntryMessagesExcTv
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See RS-XX8000-COMMON-MIB - TextualConvention for details."
 | 
						|
            ::= { exciterALogbookEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        excALogbookDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The time of the logbook entry."
 | 
						|
            ::= { exciterALogbookEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageANumberOfEntries OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of entries in logbook."
 | 
						|
            ::= { logbook 7 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageALogbookClear OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Clear the logbook.
 | 
						|
                idle(1)    --> ready
 | 
						|
                clear(2)   --> do clear now
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { logbook 8 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageALogbookTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF OutputstageALogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "OutputstageA logbook table."
 | 
						|
            ::= { logbook 9 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageALogbookEntry OBJECT-TYPE
 | 
						|
            SYNTAX OutputstageALogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is a entry in the logbook."
 | 
						|
            INDEX { ostALogbookEntryIdx }
 | 
						|
            ::= { outputstageALogbookTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        OutputstageALogbookEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                ostALogbookEntryIdx
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                ostALogbookEntryNbr
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                ostALogbookType
 | 
						|
                    EventClass,
 | 
						|
                ostALogbookSlope
 | 
						|
                    LogbookEntrySlope,
 | 
						|
                ostALogbookMessage
 | 
						|
                    LogbookEntryMessagesOST,
 | 
						|
                ostALogbookDateTime
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        ostALogbookEntryIdx OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is an increasing number from 1 to maximum. It is used as an index column for SNMP."
 | 
						|
            ::= { outputstageALogbookEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ostALogbookEntryNbr OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the number of the logbook entry. It is an decreasing number from maximum down to 1."
 | 
						|
            ::= { outputstageALogbookEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        ostALogbookType OBJECT-TYPE
 | 
						|
            SYNTAX EventClass
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Can either be Fault, Warning or State."
 | 
						|
            ::= { outputstageALogbookEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        ostALogbookSlope OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntrySlope
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Either set (event raises) or reset (event disappears)"
 | 
						|
            ::= { outputstageALogbookEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        ostALogbookMessage OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntryMessagesOST
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See RS-XX8000-COMMON-MIB - TextualConvention for details."
 | 
						|
            ::= { outputstageALogbookEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        ostALogbookDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The time of the logbook entry."
 | 
						|
            ::= { outputstageALogbookEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterBNumberOfEntries OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of entries in logbook."
 | 
						|
            ::= { logbook 10 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterBLogbookClear OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Clear the logbook.
 | 
						|
                idle(1)    --> ready
 | 
						|
                clear(2)   --> do clear now
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { logbook 11 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterBLogbookTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF ExciterBLogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "ExciterB logbook table."
 | 
						|
            ::= { logbook 12 }
 | 
						|
 | 
						|
        
 | 
						|
        exciterBLogbookEntry OBJECT-TYPE
 | 
						|
            SYNTAX ExciterBLogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is a entry in the logbook."
 | 
						|
            INDEX { excBLogbookEntryIdx }
 | 
						|
            ::= { exciterBLogbookTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ExciterBLogbookEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                excBLogbookEntryIdx
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                excBLogbookEntryNbr
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                excBLogbookType
 | 
						|
                    EventClass,
 | 
						|
                excBLogbookSlope
 | 
						|
                    LogbookEntrySlope,
 | 
						|
                excBLogbookMessage
 | 
						|
                    LogbookEntryMessagesExcTv,
 | 
						|
                excBLogbookDateTime
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        excBLogbookEntryIdx OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is an increasing number from 1 to maximum. It is used as an index column for SNMP."
 | 
						|
            ::= { exciterBLogbookEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        excBLogbookEntryNbr OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the number of the logbook entry. It is an decreasing number from maximum down to 1."
 | 
						|
            ::= { exciterBLogbookEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        excBLogbookType OBJECT-TYPE
 | 
						|
            SYNTAX EventClass
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Can either be Fault, Warning or State."
 | 
						|
            ::= { exciterBLogbookEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        excBLogbookSlope OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntrySlope
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Either set (event raises) or reset (event disappears)"
 | 
						|
            ::= { exciterBLogbookEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        excBLogbookMessage OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntryMessagesExcTv
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See RS-XX8000-COMMON-MIB - TextualConvention for details."
 | 
						|
            ::= { exciterBLogbookEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        excBLogbookDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The time of the logbook entry."
 | 
						|
            ::= { exciterBLogbookEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageBNumberOfEntries OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of entries in logbook."
 | 
						|
            ::= { logbook 13 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageBLogbookClear OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Clear the logbook.
 | 
						|
                idle(1)    --> ready
 | 
						|
                clear(2)   --> do clear now
 | 
						|
                
 | 
						|
                A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything."
 | 
						|
            ::= { logbook 14 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageBLogbookTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF OutputstageBLogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "OutputstageB logbook table."
 | 
						|
            ::= { logbook 15 }
 | 
						|
 | 
						|
        
 | 
						|
        outputstageBLogbookEntry OBJECT-TYPE
 | 
						|
            SYNTAX OutputstageBLogbookEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is a entry in the logbook."
 | 
						|
            INDEX { ostBLogbookEntryIdx }
 | 
						|
            ::= { outputstageBLogbookTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        OutputstageBLogbookEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                ostBLogbookEntryIdx
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                ostBLogbookEntryNbr
 | 
						|
                    LogbookMaxEntryNumber,
 | 
						|
                ostBLogbookType
 | 
						|
                    EventClass,
 | 
						|
                ostBLogbookSlope
 | 
						|
                    LogbookEntrySlope,
 | 
						|
                ostBLogbookMessage
 | 
						|
                    LogbookEntryMessagesOST,
 | 
						|
                ostBLogbookDateTime
 | 
						|
                    DateAndTime
 | 
						|
             }
 | 
						|
 | 
						|
        ostBLogbookEntryIdx OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is an increasing number from 1 to 128. It is used as an index column for SNMP."
 | 
						|
            ::= { outputstageBLogbookEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        ostBLogbookEntryNbr OBJECT-TYPE
 | 
						|
            SYNTAX LogbookMaxEntryNumber
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This is the number of the logbook entry. It is an decreasing number from max 128 down to 1."
 | 
						|
            ::= { outputstageBLogbookEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        ostBLogbookType OBJECT-TYPE
 | 
						|
            SYNTAX EventClass
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Can either be Fault, Warning or State."
 | 
						|
            ::= { outputstageBLogbookEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        ostBLogbookSlope OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntrySlope
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Either set (event raises) or reset (event disappears)"
 | 
						|
            ::= { outputstageBLogbookEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        ostBLogbookMessage OBJECT-TYPE
 | 
						|
            SYNTAX LogbookEntryMessagesOST
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See RS-XX8000-COMMON-MIB - TextualConvention for details."
 | 
						|
            ::= { outputstageBLogbookEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        ostBLogbookDateTime OBJECT-TYPE
 | 
						|
            SYNTAX DateAndTime
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The time of the logbook entry."
 | 
						|
            ::= { outputstageBLogbookEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF RfProbesEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This table contains all commands for the RF probes."
 | 
						|
            ::= { rsXx8000DvbTxObjs 5 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesEntry OBJECT-TYPE
 | 
						|
            SYNTAX RfProbesEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for a designated transmitter and device."
 | 
						|
            INDEX { rfProbesOstIdx }
 | 
						|
            ::= { rfProbesTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        RfProbesEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                rfProbesNetCCURfProbe1
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesNetCCURfProbe2
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesAntFwdNominal
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesAntFwdWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesAntFwdFailLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesAntFwdDelayTimeRfFail
 | 
						|
                    Integer32,
 | 
						|
                rfProbesAntFwdSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesAntFwdSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbesAntReflWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesAntReflSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesAntReflSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbesDLFwdNominal
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesDLFwdWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesDLFwdFailLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesDLFwdDelayTimeRfFail
 | 
						|
                    Integer32,
 | 
						|
                rfProbesDLFwdSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesDLFwdSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbesDLReflWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesDLReflSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesDLReflSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbesOstIdx
 | 
						|
                    IndexAB,
 | 
						|
                rfProbesOstFwdNominal
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesOstFwdWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesOstFwdFailLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesOstFwdDelayTimeRfFail
 | 
						|
                    Integer32,
 | 
						|
                rfProbesOstFwdSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesOstFwdSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbesOstReflWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbesOstReflSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbesOstReflSetGain
 | 
						|
                    Trigger
 | 
						|
             }
 | 
						|
 | 
						|
        rfProbesNetCCURfProbe1 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Current voltage on RF Probe 1."
 | 
						|
            ::= { rfProbesEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesNetCCURfProbe2 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Current voltage on RF Probe 2."
 | 
						|
            ::= { rfProbesEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdNominal OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the nominal value [W] of the transmitter (to antenna)."
 | 
						|
            ::= { rfProbesEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the transmitters RF control (to antenna)."
 | 
						|
            ::= { rfProbesEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdFailLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the fault limit for the transmitters RF control (to antenna)."
 | 
						|
            ::= { rfProbesEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdDelayTimeRfFail OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..20)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the delay time for the RF Fail control (to antenna)."
 | 
						|
            ::= { rfProbesEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntFwdSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntReflWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the transmitters reflection control (to antenna)."
 | 
						|
            ::= { rfProbesEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntReflSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesAntReflSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdNominal OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the nominal value [W] of the transmitter (to dummyload)."
 | 
						|
            ::= { rfProbesEntry 12 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the transmitters RF control (to dummyload)."
 | 
						|
            ::= { rfProbesEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdFailLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the fault limit for the transmitters RF control (to dummyload)."
 | 
						|
            ::= { rfProbesEntry 14 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdDelayTimeRfFail OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..20)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the delay time for the RF Fail control (to dummyload)."
 | 
						|
            ::= { rfProbesEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 16 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLFwdSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 17 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLReflWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the transmitters reflection control (to dummyload)."
 | 
						|
            ::= { rfProbesEntry 18 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLReflSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 19 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesDLReflSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 20 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The dedicated outputstage (A/B)."
 | 
						|
            ::= { rfProbesEntry 21 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdNominal OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the nominal value [W] of the outputstage."
 | 
						|
            ::= { rfProbesEntry 22 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the outputstage RF control."
 | 
						|
            ::= { rfProbesEntry 23 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdFailLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the fault limit for the outputstage RF control."
 | 
						|
            ::= { rfProbesEntry 24 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdDelayTimeRfFail OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..20)
 | 
						|
            UNITS "seconds"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the delay time for the outputstage RF Fail control."
 | 
						|
            ::= { rfProbesEntry 25 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 26 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstFwdSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 27 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstReflWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This sets the warning limit for the outputstage reflection control."
 | 
						|
            ::= { rfProbesEntry 28 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstReflSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Offset."
 | 
						|
            ::= { rfProbesEntry 29 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbesOstReflSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This triggers Set Gain."
 | 
						|
            ::= { rfProbesEntry 30 }
 | 
						|
 | 
						|
        
 | 
						|
        rackTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF RackEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This table contains important commands for the racks."
 | 
						|
            ::= { rsXx8000DvbTxObjs 6 }
 | 
						|
 | 
						|
        
 | 
						|
        rackEntry OBJECT-TYPE
 | 
						|
            SYNTAX RackEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An entry for a designated rack or rack's rf probe."
 | 
						|
            INDEX { ostDeviceIdx, rackIdx, rackRfProbeIdx }
 | 
						|
            ::= { rackTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        RackEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                ostDeviceIdx
 | 
						|
                    IndexAB,
 | 
						|
                rackIdx
 | 
						|
                    IndexRack,
 | 
						|
                rackRfProbeIdx
 | 
						|
                    INTEGER,
 | 
						|
                amplifiersPerRack
 | 
						|
                    Integer32,
 | 
						|
                rackRfEventSignalling
 | 
						|
                    TruthValue,
 | 
						|
                rackReferenceVoltage
 | 
						|
                    FloatingPoint,
 | 
						|
                amplifiersPowerSupply
 | 
						|
                    FloatingPoint,
 | 
						|
                rackGeneralPurposeInput
 | 
						|
                    INTEGER,
 | 
						|
                rackOnOff
 | 
						|
                    SwitchOnOff,
 | 
						|
                rfProbePresent
 | 
						|
                    TruthValue,
 | 
						|
                rfProbeConfigurationLabel
 | 
						|
                    ReadableString,
 | 
						|
                rfProbeConfigurationNominalValue
 | 
						|
                    Integer32,
 | 
						|
                rfProbeThresholdRfFailLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbeThresholdTimeoutRfFailCtr
 | 
						|
                    Integer32,
 | 
						|
                rfProbeThresholdWarningLimit
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbeCalibrationGain
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbeCalibrationOffset
 | 
						|
                    FloatingPoint,
 | 
						|
                rfProbeCalibrationSetGain
 | 
						|
                    Trigger,
 | 
						|
                rfProbeCalibrationSetOffset
 | 
						|
                    Trigger,
 | 
						|
                rfProbeMeasuredValue
 | 
						|
                    FloatingPoint
 | 
						|
             }
 | 
						|
 | 
						|
        ostDeviceIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAB
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index to address outputstageA and outputstageB."
 | 
						|
            ::= { rackEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        rackIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexRack
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index to address the racks."
 | 
						|
            ::= { rackEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        rackRfProbeIdx OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                forward(1),
 | 
						|
                reflected(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The index to address forward and reflected RF probes.
 | 
						|
                For not RF probe parameters this index is always 1."
 | 
						|
            ::= { rackEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        amplifiersPerRack OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..10)
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of amplifiers of a rack."
 | 
						|
            ::= { rackEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        rackRfEventSignalling OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This configures whether to signal rf events or not."
 | 
						|
            ::= { rackEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        rackReferenceVoltage OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This parameter controls the reference voltage (31.0 ... 100.0)."
 | 
						|
            ::= { rackEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        amplifiersPowerSupply OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "percent"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This parameter controls the power supplies of the amplifier 
 | 
						|
                within the rack (31.0 ... 100.0)."
 | 
						|
            ::= { rackEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        rackGeneralPurposeInput OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                unused(1),
 | 
						|
                doorOpen(2),
 | 
						|
                extCoolingWarning(3),
 | 
						|
                extCoolingFault(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Setting of the general purpose input behaviour."
 | 
						|
            ::= { rackEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        rackOnOff OBJECT-TYPE
 | 
						|
            SYNTAX SwitchOnOff
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This switches the rack on/off."
 | 
						|
            ::= { rackEntry 20 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbePresent OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "If the RF probe of this rack is present."
 | 
						|
            ::= { rackEntry 50 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeConfigurationLabel OBJECT-TYPE
 | 
						|
            SYNTAX ReadableString (SIZE (0..12))
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION
 | 
						|
                "Name for the measured signal on RF Probe."
 | 
						|
            ::= { rackEntry 51 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeConfigurationNominalValue OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (0..100000)
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The nominal value of the measured signal."
 | 
						|
            ::= { rackEntry 52 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeThresholdRfFailLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Fault limit for the RF control (-20.0 ... 0.0)."
 | 
						|
            ::= { rackEntry 55 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeThresholdTimeoutRfFailCtr OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..20)
 | 
						|
            UNITS "s"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Timeout for RF Fail Control."
 | 
						|
            ::= { rackEntry 56 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeThresholdWarningLimit OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Warning limit for the RF control (-20.0 ... 0.0).
 | 
						|
                
 | 
						|
                For reflected probes:
 | 
						|
                Warning limit for the reflection control. This limit is added to the 
 | 
						|
                fault limit to generate the real warning limit; e.g. the fault limit 
 | 
						|
                is -17.0dB and the warning limit is -3.0dB, so the warning is active 
 | 
						|
                on a reflected power higher than -20.0 dB."
 | 
						|
            ::= { rackEntry 57 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeCalibrationGain OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "V"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Measured value of gain calibration."
 | 
						|
            ::= { rackEntry 60 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeCalibrationOffset OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "V"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Measured value of offset calibration."
 | 
						|
            ::= { rackEntry 61 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeCalibrationSetGain OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Sets the gain calibration."
 | 
						|
            ::= { rackEntry 62 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeCalibrationSetOffset OBJECT-TYPE
 | 
						|
            SYNTAX Trigger
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Sets the offset calibration."
 | 
						|
            ::= { rackEntry 63 }
 | 
						|
 | 
						|
        
 | 
						|
        rfProbeMeasuredValue OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "W"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Measured forward/reflected power of antenna signal."
 | 
						|
            ::= { rackEntry 65 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmplifierTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF Sx801AmplifierEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Amplifier status values for SX801 amplifiers."
 | 
						|
            ::= { rsXx8000DvbTxObjs 7 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmplifierEntry OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A row (an entry) for one amplifier."
 | 
						|
            INDEX { sx801AmpIdx }
 | 
						|
            ::= { sx801AmplifierTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        Sx801AmplifierEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                sx801AmpIdx
 | 
						|
                    IndexAmplifier,
 | 
						|
                sx801AmpRfOut
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpRfIn
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpReflection
 | 
						|
                    INTEGER,
 | 
						|
                sx801AmpOn
 | 
						|
                    INTEGER,
 | 
						|
                sx801AmpAC
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpCommunication
 | 
						|
                    INTEGER,
 | 
						|
                sx801AmpTransistor
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpDriver
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpTemperature
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpBlower
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpRegulation
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpUpdate
 | 
						|
                    TruthValue,
 | 
						|
                sx801Supply1Temperature
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801Supply2Temperature
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801SupplyRTemperature
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801Supply1DC
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801Supply2DC
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801SupplyRDC
 | 
						|
                    Sx801AmplifierState,
 | 
						|
                sx801AmpValueI1
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueI2
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueI3
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueI4
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueIPre
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueIDrv1
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueIDrv2
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValuePowerOut
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueReflection
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueVRef
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueVReg
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueTemperature
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueMonAtt
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueVAux1
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801AmpValueVAux2
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801Supply1ValuePwr
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801Supply2ValuePwr
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801Supply1ValueDc
 | 
						|
                    FloatingPoint,
 | 
						|
                sx801Supply2ValueDc
 | 
						|
                    FloatingPoint
 | 
						|
             }
 | 
						|
 | 
						|
        sx801AmpIdx OBJECT-TYPE
 | 
						|
            SYNTAX IndexAmplifier
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The amplifier index."
 | 
						|
            ::= { sx801AmplifierEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpRfOut OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows if the amplifier generates an RF or not.
 | 
						|
                off(1): The amplifier output is switched off
 | 
						|
                e.g. because the amplifier gets no input signal or the transmitter has been switched off
 | 
						|
                warning(2): There is an RF but its level is less than the RF warning limit.
 | 
						|
                ok(3): The RF level is greater than the RF warning limit."
 | 
						|
            ::= { sx801AmplifierEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpRfIn OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Displays the state of the amplifier input.
 | 
						|
                off(1): no input signal detected
 | 
						|
                warning(2): the level of the input signal is too low or too high.
 | 
						|
                ok(3): input signal is OK."
 | 
						|
            ::= { sx801AmplifierEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpReflection OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                warning(2),
 | 
						|
                unknown(3),
 | 
						|
                fault(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                " A reflection on RF output of this Amplifier module has been detected.
 | 
						|
                This leads to a reduction of output power of the amplifier.
 | 
						|
                
 | 
						|
                "
 | 
						|
            ::= { sx801AmplifierEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpOn OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                on(3),
 | 
						|
                unknown(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows if the amplifier has been switched on by the control unit."
 | 
						|
            ::= { sx801AmplifierEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpAC OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows the state of primary voltage of the power supply."
 | 
						|
            ::= { sx801AmplifierEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpCommunication OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                off(1),
 | 
						|
                unknown(2),
 | 
						|
                ok(3),
 | 
						|
                fault(4)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Displays if the CAN communication between amplifier and Sx801 is working or not."
 | 
						|
            ::= { sx801AmplifierEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpTransistor OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "A transistor fail is displayed here.
 | 
						|
                For further information please see the amplifiers service menue."
 | 
						|
            ::= { sx801AmplifierEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpDriver OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a failure if one of the internal driver transistors does not work properly.
 | 
						|
                For further information please see the amplifiers service menue."
 | 
						|
            ::= { sx801AmplifierEntry 9 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpTemperature OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the temperature of amplifier module is too high."
 | 
						|
            ::= { sx801AmplifierEntry 10 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpBlower OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Displays the state of the internal blowers."
 | 
						|
            ::= { sx801AmplifierEntry 11 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpRegulation OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the amplifier is not able to control its output power."
 | 
						|
            ::= { sx801AmplifierEntry 12 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpUpdate OBJECT-TYPE
 | 
						|
            SYNTAX TruthValue
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Firmware update is in progress.
 | 
						|
                This will be started automatically during a software update procedure of the transmitter."
 | 
						|
            ::= { sx801AmplifierEntry 13 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply1Temperature OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the temperature of power supply one is too high."
 | 
						|
            ::= { sx801AmplifierEntry 14 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply2Temperature OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the temperature of power supply two is too high."
 | 
						|
            ::= { sx801AmplifierEntry 15 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801SupplyRTemperature OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the temperature of the reserve power supply is too high."
 | 
						|
            ::= { sx801AmplifierEntry 16 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply1DC OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the output voltage of power supply one is not ok."
 | 
						|
            ::= { sx801AmplifierEntry 17 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply2DC OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the output voltage of power supply two is not ok."
 | 
						|
            ::= { sx801AmplifierEntry 18 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801SupplyRDC OBJECT-TYPE
 | 
						|
            SYNTAX Sx801AmplifierState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "Shows a fault if the output voltage of the reserve power supply is not ok."
 | 
						|
            ::= { sx801AmplifierEntry 19 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueI1 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from transistor pair 1."
 | 
						|
            ::= { sx801AmplifierEntry 50 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueI2 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from transistor pair 2."
 | 
						|
            ::= { sx801AmplifierEntry 51 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueI3 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from transistor pair 3."
 | 
						|
            ::= { sx801AmplifierEntry 52 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueI4 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from transistor pair 4."
 | 
						|
            ::= { sx801AmplifierEntry 53 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueIPre OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from preamplifier."
 | 
						|
            ::= { sx801AmplifierEntry 54 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueIDrv1 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from driver transistor pair 1."
 | 
						|
            ::= { sx801AmplifierEntry 55 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueIDrv2 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Ampere"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal current from driver transistor pair 2."
 | 
						|
            ::= { sx801AmplifierEntry 56 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValuePowerOut OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The base value in Volt to calculate the output power
 | 
						|
                of this amplifier module."
 | 
						|
            ::= { sx801AmplifierEntry 57 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueReflection OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Watt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The base value in Volt for detection of reflections."
 | 
						|
            ::= { sx801AmplifierEntry 58 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueVRef OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal reference voltage to set the output power."
 | 
						|
            ::= { sx801AmplifierEntry 59 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueVReg OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal value for output power regulation."
 | 
						|
            ::= { sx801AmplifierEntry 60 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueTemperature OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "degree Celsius"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal temperature of Amplifier.
 | 
						|
                In case of L-band amplifier, the shown temperature is valid only,
 | 
						|
                if the amplifier is switched on."
 | 
						|
            ::= { sx801AmplifierEntry 61 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueMonAtt OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "dB"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The attenuation of monitoring output on the front of the
 | 
						|
                amplifier module (Amp RF Mon)."
 | 
						|
            ::= { sx801AmplifierEntry 62 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueVAux1 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage power detector 1."
 | 
						|
            ::= { sx801AmplifierEntry 63 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801AmpValueVAux2 OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The voltage power detector 2."
 | 
						|
            ::= { sx801AmplifierEntry 64 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply1ValuePwr OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power supply one control voltage."
 | 
						|
            ::= { sx801AmplifierEntry 65 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply2ValuePwr OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The power supply two control voltage."
 | 
						|
            ::= { sx801AmplifierEntry 66 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply1ValueDc OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal supply voltage of transistor path two.
 | 
						|
                In systems with two power supplies this value is equal
 | 
						|
                to the output voltage of supply one."
 | 
						|
            ::= { sx801AmplifierEntry 67 }
 | 
						|
 | 
						|
        
 | 
						|
        sx801Supply2ValueDc OBJECT-TYPE
 | 
						|
            SYNTAX FloatingPoint
 | 
						|
            UNITS "Volt"
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The internal supply voltage of transistor path two.
 | 
						|
                In systems with two power supplies this value is equal
 | 
						|
                to the output voltage of supply two."
 | 
						|
            ::= { sx801AmplifierEntry 68 }
 | 
						|
 | 
						|
        
 | 
						|
-- *****************************************************************************
 | 
						|
-- **          event definitions
 | 
						|
-- *****************************************************************************
 | 
						|
        rsXx8000DvbTxEvents OBJECT IDENTIFIER ::= { rsXx8000DvbTx 3 }
 | 
						|
 | 
						|
        
 | 
						|
-- *****************************************************************************
 | 
						|
-- **          events transmitter
 | 
						|
-- *****************************************************************************
 | 
						|
        eventTx OBJECT IDENTIFIER ::= { rsXx8000DvbTxEvents 2 }
 | 
						|
 | 
						|
        
 | 
						|
        eventsTxV2 OBJECT-IDENTITY
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Compatibility to SMIv1."
 | 
						|
            ::= { eventTx 0 }
 | 
						|
 | 
						|
        
 | 
						|
        txSummaryFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Transmitter Summary Fault"
 | 
						|
            ::= { eventsTxV2 1 }
 | 
						|
 | 
						|
        
 | 
						|
        txSummaryWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Transmitter Summary Warning"
 | 
						|
            ::= { eventsTxV2 2 }
 | 
						|
 | 
						|
        
 | 
						|
        txLocal NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Transmitter Local/Remote"
 | 
						|
            ::= { eventsTxV2 3 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Transmitter RF On/Off"
 | 
						|
            ::= { eventsTxV2 4 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Transmitter RF Ok / Not OK"
 | 
						|
            ::= { eventsTxV2 5 }
 | 
						|
 | 
						|
        
 | 
						|
        txParamSetSubDeviceDiffers NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION 
 | 
						|
                "Parameterset of subdevice is different.
 | 
						|
                The currently loaded parameterset is inconsistent because
 | 
						|
                a subdevice (e.g. an exciter) has a different configuration than expected.
 | 
						|
                To correct this, save settings to the current or save a complete new."
 | 
						|
            ::= { eventsTxV2 6 }
 | 
						|
 | 
						|
        
 | 
						|
        txParamSetValuesChanged NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Value Of Current Parameterset Changed.
 | 
						|
                The currently loaded parameterset is inconsistent because
 | 
						|
                there were changes happening since the load/save of it.
 | 
						|
                To correct this, save settings to the current or save a complete new."
 | 
						|
            ::= { eventsTxV2 7 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfLoopProgram NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Loop Program"
 | 
						|
            ::= { eventsTxV2 8 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfLoopReserve NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Loop Reserve"
 | 
						|
            ::= { eventsTxV2 9 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU RF Warning"
 | 
						|
            ::= { eventsTxV2 10 }
 | 
						|
 | 
						|
        
 | 
						|
        txReflectionWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Reflection Warning"
 | 
						|
            ::= { eventsTxV2 11 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUFanFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Fan Fault.
 | 
						|
                This is valid, if Fan Control is switched on (see menu NetCCU Setup - Common)."
 | 
						|
            ::= { eventsTxV2 12 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUPowerSupply NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Power Supply"
 | 
						|
            ::= { eventsTxV2 13 }
 | 
						|
 | 
						|
        
 | 
						|
        txRfFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU RF Fail"
 | 
						|
            ::= { eventsTxV2 14 }
 | 
						|
 | 
						|
        
 | 
						|
        txReflectionFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Reflection Fault"
 | 
						|
            ::= { eventsTxV2 15 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUBoardTemperatureFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS deprecated
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Board Temperature Fault
 | 
						|
                
 | 
						|
                deprecated: this information is now handled as a warning
 | 
						|
                (txNetCCUBoardTemperatureWarning)"
 | 
						|
            ::= { eventsTxV2 16 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUNoConnectionToExcA NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Connection To ExciterA Faulty"
 | 
						|
            ::= { eventsTxV2 17 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUNoConnectionToOstA NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Connection To OutputstageA Faulty"
 | 
						|
            ::= { eventsTxV2 18 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUNoConnectionToExcB NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Connection To ExciterB Faulty"
 | 
						|
            ::= { eventsTxV2 19 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUNoConnectionToOstB NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Connection To OutputstageB Faulty"
 | 
						|
            ::= { eventsTxV2 20 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticExcReady NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Automatic Ready."
 | 
						|
            ::= { eventsTxV2 21 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticExcChanged NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Automatic Changed."
 | 
						|
            ::= { eventsTxV2 22 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticExcFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Automatic Fault."
 | 
						|
            ::= { eventsTxV2 23 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticOstReady NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Automatic Ready.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { eventsTxV2 24 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticOstChanged NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Automatic Changed.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { eventsTxV2 25 }
 | 
						|
 | 
						|
        
 | 
						|
        txAutomaticOstFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Automatic Fault.
 | 
						|
                
 | 
						|
                This paramter is only available for systems with an automatic output switch."
 | 
						|
            ::= { eventsTxV2 26 }
 | 
						|
 | 
						|
        
 | 
						|
        txNetCCUBoardTemperatureWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU Board Temperature Warning"
 | 
						|
            ::= { eventsTxV2 27 }
 | 
						|
 | 
						|
        
 | 
						|
        txInternalPowerSupplyWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU internal Power Supply warning"
 | 
						|
            ::= { eventsTxV2 30 }
 | 
						|
 | 
						|
        
 | 
						|
        txExternalPowerSupplyWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "NetCCU external (additional) Power Supply warning"
 | 
						|
            ::= { eventsTxV2 31 }
 | 
						|
 | 
						|
        
 | 
						|
        txModeSwitchOverStarted NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Switch over of TX mode started."
 | 
						|
            ::= { eventsTxV2 35 }
 | 
						|
 | 
						|
        
 | 
						|
        txModeSwitchOverEnded NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Switch over of TX mode ended."
 | 
						|
            ::= { eventsTxV2 36 }
 | 
						|
 | 
						|
        
 | 
						|
        txModeInconsistent NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "An inconsistency in configuration of TX mode was detected.
 | 
						|
                The CCU and exiter configurations are incompatible."
 | 
						|
            ::= { eventsTxV2 37 }
 | 
						|
 | 
						|
        
 | 
						|
        txModeSwitchOverFailed NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Switch over of TX mode failed.
 | 
						|
                Please check whether the configurations of CCU and exciter are correct."
 | 
						|
            ::= { eventsTxV2 38 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcSummaryFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Summary Fault"
 | 
						|
            ::= { eventsTxV2 100 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcSummaryWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Summary Warning"
 | 
						|
            ::= { eventsTxV2 101 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcLocal NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Local/Remote"
 | 
						|
            ::= { eventsTxV2 102 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcRfOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter RF Ok"
 | 
						|
            ::= { eventsTxV2 104 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputNoConnectHP1 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input HP1 has no connected input signal"
 | 
						|
            ::= { eventsTxV2 105 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputNoConnectLP1 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input LP1 has no connected input signal"
 | 
						|
            ::= { eventsTxV2 106 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputNoConnectHP2 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input HP2 has no connected input signal"
 | 
						|
            ::= { eventsTxV2 107 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputNoConnectLP2 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input LP2 has no connected input signal"
 | 
						|
            ::= { eventsTxV2 108 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputActiveHP1 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input HP1 is active"
 | 
						|
            ::= { eventsTxV2 109 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputActiveLP1 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input LP1 is active"
 | 
						|
            ::= { eventsTxV2 110 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputActiveHP2 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input HP2 is active"
 | 
						|
            ::= { eventsTxV2 111 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputActiveLP2 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Input LP2 is active"
 | 
						|
            ::= { eventsTxV2 112 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter On"
 | 
						|
            ::= { eventsTxV2 113 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcRfOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter RF On"
 | 
						|
            ::= { eventsTxV2 114 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcNoInput NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter has no valid input signal."
 | 
						|
            ::= { eventsTxV2 115 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcRfLoop NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter RF loop"
 | 
						|
            ::= { eventsTxV2 116 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcRfFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter RF Fail"
 | 
						|
            ::= { eventsTxV2 117 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcSelfTest NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter hardware self test"
 | 
						|
            ::= { eventsTxV2 118 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcOutputOpen NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter output open"
 | 
						|
            ::= { eventsTxV2 119 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcBoardTemperatureWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Board Temperature"
 | 
						|
            ::= { eventsTxV2 120 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcFanWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter has one faulty fan"
 | 
						|
            ::= { eventsTxV2 121 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcFanFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Both exciter fans are faulty."
 | 
						|
            ::= { eventsTxV2 122 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcFifoWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Fifo"
 | 
						|
            ::= { eventsTxV2 123 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcTestSignal NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Testsignal Active"
 | 
						|
            ::= { eventsTxV2 124 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcSFNDelay NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter SFN Delay Fault"
 | 
						|
            ::= { eventsTxV2 125 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcWrongDatarate NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Wrong Datarate"
 | 
						|
            ::= { eventsTxV2 126 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcMute NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Mute"
 | 
						|
            ::= { eventsTxV2 127 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcPPSFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter PPS Fail"
 | 
						|
            ::= { eventsTxV2 128 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcReferenceFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter Reference Fail"
 | 
						|
            ::= { eventsTxV2 129 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcMIPFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Exciter MIP Fail"
 | 
						|
            ::= { eventsTxV2 130 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputAutomaticSwitchReady NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Input automatic is ready."
 | 
						|
            ::= { eventsTxV2 131 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputAutomaticChangedOver NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Input automatic changed over."
 | 
						|
            ::= { eventsTxV2 132 }
 | 
						|
 | 
						|
        
 | 
						|
        txExcInputReseveMissing NOTIFICATION-TYPE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Missing input, or automatic switching enabled with only one input present.
 | 
						|
                Disable automatic switching or press reset fault to remove this warning.
 | 
						|
                Monitoring of a second input will start automatically if two input signals have been detected.
 | 
						|
                
 | 
						|
                This event will be generated only if cmdExcExpectInputReserve is set to on(1)."
 | 
						|
            ::= { eventsTxV2 133 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstSummaryFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Summary Fault"
 | 
						|
            ::= { eventsTxV2 200 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstSummaryWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Summary Warning"
 | 
						|
            ::= { eventsTxV2 201 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstRfOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage RF On"
 | 
						|
            ::= { eventsTxV2 202 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstRfOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage RF Ok"
 | 
						|
            ::= { eventsTxV2 203 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstNoInput NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage no input signal"
 | 
						|
            ::= { eventsTxV2 204 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstRfWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage RF Warning"
 | 
						|
            ::= { eventsTxV2 205 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstReflectionWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Reflection Warning"
 | 
						|
            ::= { eventsTxV2 206 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstRackWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Rack Warning. At least one rack has an error pending."
 | 
						|
            ::= { eventsTxV2 207 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstCoolingWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Cooling Warning"
 | 
						|
            ::= { eventsTxV2 208 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstRfFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage RF Fail"
 | 
						|
            ::= { eventsTxV2 209 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstReflectionFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Reflection Fault"
 | 
						|
            ::= { eventsTxV2 210 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstACFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage AC Fault"
 | 
						|
            ::= { eventsTxV2 211 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstCoolingFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Cooling Fault"
 | 
						|
            ::= { eventsTxV2 212 }
 | 
						|
 | 
						|
        
 | 
						|
        txOstCommFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Outputstage Communication Fault"
 | 
						|
            ::= { eventsTxV2 213 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackSumFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Summary Fault at a designated rack.
 | 
						|
                This event automatically leads to txOstRackWarning."
 | 
						|
            ::= { eventsTxV2 300 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackSumWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Summary Warning at a designated rack."
 | 
						|
            ::= { eventsTxV2 301 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated racks operation mode is on."
 | 
						|
            ::= { eventsTxV2 302 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackGpiWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "A warning on the general purpose input occurred.
 | 
						|
                This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)"
 | 
						|
            ::= { eventsTxV2 303 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackFan1Fault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a fault of fan 1."
 | 
						|
            ::= { eventsTxV2 304 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackFan2Fault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a fault of fan 2."
 | 
						|
            ::= { eventsTxV2 305 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackCoolingSumWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a summary cooling warning."
 | 
						|
            ::= { eventsTxV2 306 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackAmplifierSumFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals at least one faulty amplifier."
 | 
						|
            ::= { eventsTxV2 307 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackNoLink NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "No communication to the designated rack."
 | 
						|
            ::= { eventsTxV2 308 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackGpiFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "A fault on the general purpose input occurred.
 | 
						|
                This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)"
 | 
						|
            ::= { eventsTxV2 309 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackTemperatureFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a temperature fault - temperature too high."
 | 
						|
            ::= { eventsTxV2 310 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackACFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals an AC (phase) fault."
 | 
						|
            ::= { eventsTxV2 311 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackCoolingSumFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a summary cooling fault."
 | 
						|
            ::= { eventsTxV2 312 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackTempFaultAbs1 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a temperature fault of absorber 1."
 | 
						|
            ::= { eventsTxV2 313 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackTempFaultAbs2 NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a temperature fault of absorber 2."
 | 
						|
            ::= { eventsTxV2 314 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackDCFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated rack signals a DC fault."
 | 
						|
            ::= { eventsTxV2 315 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackRfOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "RF power is on."
 | 
						|
            ::= { eventsTxV2 318 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackRfOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "RF power is ok."
 | 
						|
            ::= { eventsTxV2 319 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackRfWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "RF power decreased the warning threshold."
 | 
						|
            ::= { eventsTxV2 320 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackRfFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "RF output power decreased the fault threshold."
 | 
						|
            ::= { eventsTxV2 321 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackReflectionWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The reflected power increased the warning threshold"
 | 
						|
            ::= { eventsTxV2 322 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackReflectionFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The reflected power increased the fault threshold."
 | 
						|
            ::= { eventsTxV2 323 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackProbeNotCalibrated NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "At least one probe is not calibrated."
 | 
						|
            ::= { eventsTxV2 330 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackTemperatureWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Rack temperature exceeded the warning threshold."
 | 
						|
            ::= { eventsTxV2 331 }
 | 
						|
 | 
						|
        
 | 
						|
        txRackOvervoltProtectWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Overvoltage protection is out of order."
 | 
						|
            ::= { eventsTxV2 335 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpSumFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals summary fault."
 | 
						|
            ::= { eventsTxV2 400 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpSumWarning NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals summary warning."
 | 
						|
            ::= { eventsTxV2 401 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpPowerOn NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifiers power is on."
 | 
						|
            ::= { eventsTxV2 402 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpDCOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifiers DC is ok."
 | 
						|
            ::= { eventsTxV2 403 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpACOk NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifiers AC is ok."
 | 
						|
            ::= { eventsTxV2 404 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpRfInFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals RF input fail."
 | 
						|
            ::= { eventsTxV2 405 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpRfFail NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals RF fail."
 | 
						|
            ::= { eventsTxV2 406 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpReflectionFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals a reflection fault."
 | 
						|
            ::= { eventsTxV2 407 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpTemperatureFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals a temperature fault - temperature is too high."
 | 
						|
            ::= { eventsTxV2 408 }
 | 
						|
 | 
						|
        
 | 
						|
        txAmpTransistorFault NOTIFICATION-TYPE
 | 
						|
            OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, 
 | 
						|
                indexAmplifier }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "The designated amplifier signals at least one faulty transistor."
 | 
						|
            ::= { eventsTxV2 409 }
 | 
						|
 | 
						|
        
 | 
						|
        eventsTxTable OBJECT-TYPE
 | 
						|
            SYNTAX SEQUENCE OF EventsTxEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "This table contains necessary information for handling alarms. 
 | 
						|
                For each alarm you have the following information: 
 | 
						|
                - name (get),
 | 
						|
                - mask to enable/disable sending out (set/get),
 | 
						|
                - priority (set/get) and 
 | 
						|
                - the current state (get only)."
 | 
						|
            ::= { eventTx 1 }
 | 
						|
 | 
						|
        
 | 
						|
        eventsTxEntry OBJECT-TYPE
 | 
						|
            SYNTAX EventsTxEntry
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "An event entry always consists of its indexes
 | 
						|
                (used for addressing within redundancy systems) and 3 values:
 | 
						|
                - name: an enumerated list of all possible notifications
 | 
						|
                - mask: the corresponding mask (enable/disable)
 | 
						|
                - priority: the corresponding priority (value in range 0..255)
 | 
						|
                - event: the event itself (active/inactive)"
 | 
						|
            INDEX { eventTxABIdx, eventTxRackIdx, eventTxAmpIdx, eventTxNameIdx }
 | 
						|
            ::= { eventsTxTable 1 }
 | 
						|
 | 
						|
        
 | 
						|
        EventsTxEntry ::=
 | 
						|
            SEQUENCE { 
 | 
						|
                eventTxABIdx
 | 
						|
                    INTEGER,
 | 
						|
                eventTxRackIdx
 | 
						|
                    Integer32,
 | 
						|
                eventTxAmpIdx
 | 
						|
                    Integer32,
 | 
						|
                eventTxNameIdx
 | 
						|
                    EventMaxEntryNumber,
 | 
						|
                eventTxName
 | 
						|
                    INTEGER,
 | 
						|
                eventTxMask
 | 
						|
                    EventMask,
 | 
						|
                eventTxPriority
 | 
						|
                    EventPriority,
 | 
						|
                eventTxEvent
 | 
						|
                    EventState
 | 
						|
             }
 | 
						|
 | 
						|
        eventTxABIdx OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                a(1),
 | 
						|
                b(2)
 | 
						|
                }
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The value for the module A (exciterA, outputstageA) or 
 | 
						|
                B (exciterB, outputstageB) for alarms.
 | 
						|
                This is a helper column and therefore not-accessible."
 | 
						|
            ::= { eventsTxEntry 1 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxRackIdx OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..10)
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of the designated rack.
 | 
						|
                This is a helper column and therefore not-accessible."
 | 
						|
            ::= { eventsTxEntry 2 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxAmpIdx OBJECT-TYPE
 | 
						|
            SYNTAX Integer32 (1..10)
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The number of the designated amplifier.
 | 
						|
                This is a helper column and therefore not-accessible."
 | 
						|
            ::= { eventsTxEntry 3 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxNameIdx OBJECT-TYPE
 | 
						|
            SYNTAX EventMaxEntryNumber
 | 
						|
            MAX-ACCESS not-accessible
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The event number as integer.
 | 
						|
                This is a helper column and therefore not-accessible."
 | 
						|
            ::= { eventsTxEntry 4 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxName OBJECT-TYPE
 | 
						|
            SYNTAX INTEGER
 | 
						|
                {
 | 
						|
                txSummaryFault(1),
 | 
						|
                txSummaryWarning(2),
 | 
						|
                txLocal(3),
 | 
						|
                txRfOn(4),
 | 
						|
                txRfOk(5),
 | 
						|
                txParamSetSubDeviceDiffers(6),
 | 
						|
                txParamSetValuesChanged(7),
 | 
						|
                txRfLoopProgram(8),
 | 
						|
                txRfLoopReserve(9),
 | 
						|
                txRfWarning(10),
 | 
						|
                txReflectionWarning(11),
 | 
						|
                txNetCCUFanFault(12),
 | 
						|
                txNetCCUPowerSupply(13),
 | 
						|
                txRfFail(14),
 | 
						|
                txReflectionFault(15),
 | 
						|
                txNetCCUBoardTemperatureFault(16),
 | 
						|
                txNetCCUNoConnectionToExcA(17),
 | 
						|
                txNetCCUNoConnectionToOstA(18),
 | 
						|
                txNetCCUNoConnectionToExcB(19),
 | 
						|
                txNetCCUNoConnectionToOstB(20),
 | 
						|
                txAutomaticExcReady(21),
 | 
						|
                txAutomaticExcChanged(22),
 | 
						|
                txAutomaticExcFault(23),
 | 
						|
                txAutomaticOstReady(24),
 | 
						|
                txAutomaticOstChanged(25),
 | 
						|
                txAutomaticOstFault(26),
 | 
						|
                txNetCCUBoardTemperatureWarning(27),
 | 
						|
                txInternalPowerSupplyWarning(30),
 | 
						|
                txExternalPowerSupplyWarning(31),
 | 
						|
                txModeSwitchOverStarted(35),
 | 
						|
                txModeSwitchOverEnded(36),
 | 
						|
                txModeInconsistent(37),
 | 
						|
                txModeSwitchOverFailed(38),
 | 
						|
                txExcSummaryFault(100),
 | 
						|
                txExcSummaryWarning(101),
 | 
						|
                txExcLocal(102),
 | 
						|
                txExcRfOk(104),
 | 
						|
                txExcInputNoConnectHP1(105),
 | 
						|
                txExcInputNoConnectLP1(106),
 | 
						|
                txExcInputNoConnectHP2(107),
 | 
						|
                txExcInputNoConnectLP2(108),
 | 
						|
                txExcInputActiveHP1(109),
 | 
						|
                txExcInputActiveLP1(110),
 | 
						|
                txExcInputActiveHP2(111),
 | 
						|
                txExcInputActiveLP2(112),
 | 
						|
                txExcOn(113),
 | 
						|
                txExcRfOn(114),
 | 
						|
                txExcNoInput(115),
 | 
						|
                txExcRfLoop(116),
 | 
						|
                txExcRfFail(117),
 | 
						|
                txExcSelfTest(118),
 | 
						|
                txExcOutputOpen(119),
 | 
						|
                txExcBoardTemperatureWarning(120),
 | 
						|
                txExcFanWarning(121),
 | 
						|
                txExcFanFault(122),
 | 
						|
                txExcFifoWarning(123),
 | 
						|
                txExcTestSignal(124),
 | 
						|
                txExcSFNDelay(125),
 | 
						|
                txExcWrongDatarate(126),
 | 
						|
                txExcMute(127),
 | 
						|
                txExcPPSFail(128),
 | 
						|
                txExcReferenceFail(129),
 | 
						|
                txExcMIPFail(130),
 | 
						|
                txExcInputAutomaticSwitchReady(131),
 | 
						|
                txExcInputAutomaticChangedOver(132),
 | 
						|
                txExcInputReseveMissing(133),
 | 
						|
                txOstSummaryFault(200),
 | 
						|
                txOstSummaryWarning(201),
 | 
						|
                txOstRfOn(202),
 | 
						|
                txOstRfOk(203),
 | 
						|
                txOstNoInput(204),
 | 
						|
                txOstRfWarning(205),
 | 
						|
                txOstReflectionWarning(206),
 | 
						|
                txOstRackWarning(207),
 | 
						|
                txOstCoolingWarning(208),
 | 
						|
                txOstRfFail(209),
 | 
						|
                txOstReflectionFault(210),
 | 
						|
                txOstACFault(211),
 | 
						|
                txOstCoolingFault(212),
 | 
						|
                txOstCommFault(213),
 | 
						|
                txRackSumFault(300),
 | 
						|
                txRackSumWarning(301),
 | 
						|
                txRackOn(302),
 | 
						|
                txRackGpiWarning(303),
 | 
						|
                txRackFan1Fault(304),
 | 
						|
                txRackFan2Fault(305),
 | 
						|
                txRackCoolingSumWarning(306),
 | 
						|
                txRackAmplifierSumFault(307),
 | 
						|
                txRackNoLink(308),
 | 
						|
                txRackGpiFault(309),
 | 
						|
                txRackTemperatureFault(310),
 | 
						|
                txRackACFault(311),
 | 
						|
                txRackCoolingSumFault(312),
 | 
						|
                txRackTempFaultAbs1(313),
 | 
						|
                txRackTempFaultAbs2(314),
 | 
						|
                txRackDCFault(315),
 | 
						|
                txRackRfOn(318),
 | 
						|
                txRackRfOk(319),
 | 
						|
                txRackRfWarning(320),
 | 
						|
                txRackRfFault(321),
 | 
						|
                txRackReflectionWarning(322),
 | 
						|
                txRackReflectionFault(323),
 | 
						|
                txRackProbeNotCalibrated(330),
 | 
						|
                txRackTemperatureWarning(331),
 | 
						|
                txRackOvervoltProtectWarning(335),
 | 
						|
                txAmpSumFault(400),
 | 
						|
                txAmpSumWarning(401),
 | 
						|
                txAmpPowerOn(402),
 | 
						|
                txAmpDCOk(403),
 | 
						|
                txAmpACOk(404),
 | 
						|
                txAmpRfInFail(405),
 | 
						|
                txAmpRfFail(406),
 | 
						|
                txAmpReflectionFault(407),
 | 
						|
                txAmpTemperatureFault(408),
 | 
						|
                txAmpTransistorFault(409)
 | 
						|
                }
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "The event number as integer and the value as readable text.
 | 
						|
                The enumeration correlates with the notifications under eventsTxV2."
 | 
						|
            ::= { eventsTxEntry 5 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxMask OBJECT-TYPE
 | 
						|
            SYNTAX EventMask
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See TextualConvention for details."
 | 
						|
            ::= { eventsTxEntry 6 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxPriority OBJECT-TYPE
 | 
						|
            SYNTAX EventPriority
 | 
						|
            MAX-ACCESS read-write
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See TextualConvention for details."
 | 
						|
            ::= { eventsTxEntry 7 }
 | 
						|
 | 
						|
        
 | 
						|
        eventTxEvent OBJECT-TYPE
 | 
						|
            SYNTAX EventState
 | 
						|
            MAX-ACCESS read-only
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION
 | 
						|
                "See TextualConvention for details."
 | 
						|
            ::= { eventsTxEntry 8 }
 | 
						|
 | 
						|
        
 | 
						|
-- *****************************************************************************
 | 
						|
-- **          conformance statements
 | 
						|
-- *****************************************************************************
 | 
						|
        rsXx8000DvbTxConf OBJECT IDENTIFIER ::= { rsXx8000DvbTx 5 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DvbTxGroups OBJECT IDENTIFIER ::= { rsXx8000DvbTxConf 1 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEvents OBJECT-GROUP
 | 
						|
            OBJECTS { eventTxName, eventTxMask, eventTxPriority, eventTxEvent }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all OIDs for event handling."
 | 
						|
            ::= { rsXx8000DvbTxGroups 1 }
 | 
						|
 | 
						|
        
 | 
						|
        groupTxCommon OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxResetSumFault, cmdTxParametersetLoad, cmdTxParametersetSave, cmdTxOperationModeProgram, summaryFaultTx, 
 | 
						|
                summaryWarningTx, localModeTx, rfOnTx, forwardPower, summaryFaultExcA
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Group for common transmitter objects"
 | 
						|
            ::= { rsXx8000DvbTxGroups 2 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsTxCommon NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txSummaryFault, txSummaryWarning, txLocal, txRfOn, txParamSetValuesChanged, 
 | 
						|
                txRfLoopProgram, txRfFail, txOstSummaryFault, txOstSummaryWarning, txRfOk, 
 | 
						|
                txOstRfOn, txRfWarning }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all alarm OIDs that are common for all reserve concepts."
 | 
						|
            ::= { rsXx8000DvbTxGroups 3 }
 | 
						|
 | 
						|
        
 | 
						|
        groupDualDrive OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxOperationModeReserve, cmdTxOpModeExcAutomatic, cmdTxPreselectExciter, cmdTxDelayTimeExcAutomatic, exciterBNumberOfEntries, 
 | 
						|
                exciterBLogbookClear, excBLogbookEntryNbr, excBLogbookType, excBLogbookSlope, excBLogbookMessage, 
 | 
						|
                excBLogbookDateTime, summaryFaultExcB, exciterAutomaticReady, exciterAutomaticChanged, exciterAutomaticFault, 
 | 
						|
                noConnectionExcB, activeExcA, activeExcB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes additional objects for reserve concepts
 | 
						|
                DualDrive (NetCCU + 2 * exciter + outputstage)
 | 
						|
                and
 | 
						|
                Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
 | 
						|
                "
 | 
						|
            ::= { rsXx8000DvbTxGroups 4 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsDualDrive NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txRfLoopReserve, txNetCCUNoConnectionToExcB, txAutomaticExcReady, txAutomaticExcChanged, txAutomaticExcFault
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes additional events for reserve concepts
 | 
						|
                DualDrive (NetCCU + 2 * exciter + outputstage)
 | 
						|
                and
 | 
						|
                Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
 | 
						|
                "
 | 
						|
            ::= { rsXx8000DvbTxGroups 5 }
 | 
						|
 | 
						|
        
 | 
						|
        groupPowerReserve OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxOpModeOstAutomatic, cmdTxPreselectOutputstage, cmdTxDelayTimeOstAutomatic, summaryFaultOstB, outputstageAutomaticReady, 
 | 
						|
                outputstageAutomaticChanged, outputstageAutomaticFault, noConnectionOstB, activeOstA, activeOstB
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes additional objects for reserve concept
 | 
						|
                Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
 | 
						|
                For more details, refer to manual."
 | 
						|
            ::= { rsXx8000DvbTxGroups 6 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsPowerReserve NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txNetCCUNoConnectionToOstB, txAutomaticOstReady, txAutomaticOstChanged, txAutomaticOstFault }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes additional events for reserve concept
 | 
						|
                Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage)
 | 
						|
                For more details, refer to manual."
 | 
						|
            ::= { rsXx8000DvbTxGroups 7 }
 | 
						|
 | 
						|
        
 | 
						|
        groupCommonMP OBJECT-GROUP
 | 
						|
            OBJECTS { cmdOstRefVoltageVision, cmdOstMaxOutletTempThreshold, outputstageANumberOfEntries, outputstageALogbookClear, ostALogbookEntryNbr, 
 | 
						|
                ostALogbookType, ostALogbookSlope, ostALogbookMessage, ostALogbookDateTime, reflectedPower, 
 | 
						|
                ostRackInletTemperature, ostRackOutletTemperature, ostRackAuxPowerSupply, amplifiersPerRack, rackRfEventSignalling, 
 | 
						|
                rackGeneralPurposeInput, rfProbePresent, rfProbeConfigurationNominalValue, rfProbeThresholdRfFailLimit, rfProbeThresholdTimeoutRfFailCtr, 
 | 
						|
                rfProbeThresholdWarningLimit, rfProbeCalibrationGain, rfProbeCalibrationOffset, rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset, 
 | 
						|
                rfProbeMeasuredValue }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional objects for medium/high power"
 | 
						|
            ::= { rsXx8000DvbTxGroups 8 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsCommonMP NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txReflectionWarning, txReflectionFault, txOstRfOk, txOstNoInput, txOstRfWarning, 
 | 
						|
                txOstReflectionWarning, txOstRackWarning, txOstCoolingWarning, txOstRfFail, txOstReflectionFault, 
 | 
						|
                txOstACFault, txOstCoolingFault, txOstCommFault, txRackSumFault, txRackSumWarning, 
 | 
						|
                txRackOn, txRackGpiWarning, txRackFan1Fault, txRackFan2Fault, txRackCoolingSumWarning, 
 | 
						|
                txRackAmplifierSumFault, txRackNoLink, txRackGpiFault, txRackTemperatureFault, txRackACFault, 
 | 
						|
                txRackCoolingSumFault, txRackTempFaultAbs1, txRackTempFaultAbs2, txRackDCFault, txRackRfWarning, 
 | 
						|
                txRackRfFault, txRackReflectionWarning, txRackReflectionFault, txRackRfOk, txRackRfOn, 
 | 
						|
                txRackOvervoltProtectWarning, txRackTemperatureWarning, txRackProbeNotCalibrated }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional events for medium/high power"
 | 
						|
            ::= { rsXx8000DvbTxGroups 9 }
 | 
						|
 | 
						|
        
 | 
						|
        groupCommonNetCCU OBJECT-GROUP
 | 
						|
            OBJECTS { netCCUNumberOfEntries, netCCULogbookClear, netCCULogbookEntryNbr, netCCULogbookType, netCCULogbookSlope, 
 | 
						|
                netCCULogbookMessage, netCCULogbookDateTime, powerSupply, cmdTxSystemMode, additionalPowerSupply, 
 | 
						|
                summaryFaultOstA, noConnectionExcA, noConnectionOstA }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional objects for transmitters with NetCCU"
 | 
						|
            ::= { rsXx8000DvbTxGroups 10 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsCommonNetCCU NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txNetCCUFanFault, txNetCCUPowerSupply, txNetCCUNoConnectionToExcA, txNetCCUNoConnectionToOstA, txModeSwitchOverStarted, 
 | 
						|
                txModeSwitchOverEnded, txModeInconsistent, txModeSwitchOverFailed, txNetCCUBoardTemperatureWarning }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional events for transmitters with NetCCU"
 | 
						|
            ::= { rsXx8000DvbTxGroups 11 }
 | 
						|
 | 
						|
        
 | 
						|
        groupOstBLogbook OBJECT-GROUP
 | 
						|
            OBJECTS { outputstageBNumberOfEntries, outputstageBLogbookClear, ostBLogbookEntryNbr, ostBLogbookType, ostBLogbookSlope, 
 | 
						|
                ostBLogbookMessage, ostBLogbookDateTime }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "objects of logbook for output stage B"
 | 
						|
            ::= { rsXx8000DvbTxGroups 12 }
 | 
						|
 | 
						|
        
 | 
						|
        groupSumProbe OBJECT-GROUP
 | 
						|
            OBJECTS { forwardPowerOstA, reflectedPowerOstA, forwardPowerOstB, reflectedPowerOstB }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "objects that are available only when sum probe exists"
 | 
						|
            ::= { rsXx8000DvbTxGroups 14 }
 | 
						|
 | 
						|
        
 | 
						|
        groupProductInfo OBJECT-GROUP
 | 
						|
            OBJECTS { prodInfoModuleName, prodInfoSerialNumber, prodInfoIdentNumberSW, prodInfoVersionNumberSW, productInfoProductDateHW, 
 | 
						|
                prodInfoIdentNumberHW, prodInfoVersionNumberHW }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all OIDs for device product information."
 | 
						|
            ::= { rsXx8000DvbTxGroups 18 }
 | 
						|
 | 
						|
        
 | 
						|
        groupAmpMeasureValues OBJECT-GROUP
 | 
						|
            OBJECTS { ostRackAmpI1A, ostRackAmpI2A, ostRackAmpI3A, ostRackAmpI4A, ostRackAmpI1B, 
 | 
						|
                ostRackAmpI2B, ostRackAmpI3B, ostRackAmpI4B, ostRackAmpIDrv, ostRackAmpUDc, 
 | 
						|
                ostRackAmpIDc, ostRackAmpUDcControl, ostRackAmpUReg, ostRackAmpPowerA, ostRackAmpPowerB, 
 | 
						|
                ostRackAmpPowerOut, ostRackAmpPowerReflection, ostRackAmpPowerReference, ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all OIDs amplifier measure values.
 | 
						|
                Practically, these information are not important to customers, they are needed in manufactory."
 | 
						|
            ::= { rsXx8000DvbTxGroups 19 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsAmplifier NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txAmpSumFault, txAmpSumWarning, txAmpPowerOn, txAmpDCOk, txAmpACOk, 
 | 
						|
                txAmpRfInFail, txAmpRfFail, txAmpReflectionFault, txAmpTemperatureFault, txAmpTransistorFault
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "events from the amplifier (medium/high power only)"
 | 
						|
            ::= { rsXx8000DvbTxGroups 20 }
 | 
						|
 | 
						|
        
 | 
						|
        groupRfProbes OBJECT-GROUP
 | 
						|
            OBJECTS { rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2, rfProbesAntFwdNominal, rfProbesAntFwdWarningLimit, rfProbesAntFwdFailLimit, 
 | 
						|
                rfProbesAntFwdDelayTimeRfFail, rfProbesAntFwdSetOffset, rfProbesAntFwdSetGain, rfProbesAntReflWarningLimit, rfProbesAntReflSetOffset, 
 | 
						|
                rfProbesAntReflSetGain, rfProbesOstFwdNominal, rfProbesOstFwdWarningLimit, rfProbesOstFwdFailLimit, rfProbesOstFwdDelayTimeRfFail, 
 | 
						|
                rfProbesOstFwdSetOffset, rfProbesOstFwdSetGain, rfProbesOstReflWarningLimit, rfProbesOstReflSetOffset, rfProbesOstReflSetGain
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all OIDs regarding RF Probes."
 | 
						|
            ::= { rsXx8000DvbTxGroups 21 }
 | 
						|
 | 
						|
        
 | 
						|
        groupDummyLoadRF OBJECT-GROUP
 | 
						|
            OBJECTS { rfProbesDLFwdNominal, rfProbesDLFwdWarningLimit, rfProbesDLFwdFailLimit, rfProbesDLFwdDelayTimeRfFail, rfProbesDLFwdSetOffset, 
 | 
						|
                rfProbesDLFwdSetGain, rfProbesDLReflWarningLimit, rfProbesDLReflSetOffset, rfProbesDLReflSetGain }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "This group includes all object types regarding probes from dummy load.
 | 
						|
                The object types in this group are defined only when a dummy load measure point exists.
 | 
						|
                This can occur in reserve concept active reserve only.
 | 
						|
                "
 | 
						|
            ::= { rsXx8000DvbTxGroups 22 }
 | 
						|
 | 
						|
        
 | 
						|
        groupExcCommon OBJECT-GROUP
 | 
						|
            OBJECTS { cmdExcOpModeInputAutomatic, cmdExcPreselectInput, cmdExcMode, cmdExcNetworkMode, cmdExcTPSSource, 
 | 
						|
                cmdExcEnableCellID, cmdExcTxAddress, cmdExcTxAutomatic, cmdExcInputSeamless, cmdExcInputPriority, 
 | 
						|
                cmdExcInputCheckTimeForward, cmdExcInputCheckTimeSwitchback, cmdExcInputMuteOnFail, cmdExcInputManualPreseletionHP1, cmdExcInputManualPreseletionHP2, 
 | 
						|
                cmdExcInputManualPreseletionLP1, cmdExcInputManualPreseletionLP2, cmdExcTPSManualBandwidth, cmdExcTPSManualFFTLength, cmdExcTPSManualGuardInterval, 
 | 
						|
                cmdExcTPSManualConstellation, cmdExcTPSManualCellID, cmdExcTPSManualInterleaver, cmdExcTPSManualCoderateHP, cmdExcTPSManualCoderateLP, 
 | 
						|
                cmdExcTPSManualTimeSlicingHP, cmdExcTPSManualTimeSlicingLP, cmdExcTPSManualFECHP, cmdExcTPSManualFECLP, cmdExcSFNStaticDelay, 
 | 
						|
                cmdExcSFNDeviationTime, cmdExcFrequency, cmdExcReferenceSource, cmdExcMuteOnPPSFail, cmdExcMuteOnReferenceFail, 
 | 
						|
                cmdExcTypeLossOfInput, cmdExcRfOutput, cmdExcRfOutputAttenuation, cmdExcRfOutputRfSlope, cmdExcRfOutputModulationSlope, 
 | 
						|
                cmdExcRfIqAdjustTestsignal, cmdExcRfIqAdjustBiasCoarseI, cmdExcRfIqAdjustBiasCoarseQ, cmdExcRfIqAdjustBiasFineI, cmdExcRfIqAdjustBiasFineQ, 
 | 
						|
                cmdExcRfIqAdjustGainI, cmdExcRfIqAdjustGainQ, cmdExcRfIqAdjustPhase, cmdExcInpAutoReadyAfterChangeOv, excInputChannelName, 
 | 
						|
                excInputConnected, excInputSeamless, excInputPreselected, excInputActive, excInputMipFail, 
 | 
						|
                excInputBandwidth, excInputFFTLength, excInputGuardInterval, excInputConstellation, excInputCellID, 
 | 
						|
                excInputInterleaver, excInputCodeRate, excInputPacketLength, excInputMeasuredDatarate, excInputRequiredDatarate, 
 | 
						|
                excInputMaximumDelay, exciterANumberOfEntries, exciterALogbookClear, excALogbookEntryNbr, excALogbookType, 
 | 
						|
                excALogbookSlope, excALogbookMessage, excALogbookDateTime, cmdExcOcxoAdjust, cmdExcExpectInputReserve, 
 | 
						|
                excStatusReqDataRateLP, excStatusReqDataRateHP, excStatusAmplifierControl, excStatusFailDelay, cmdExcFailDelayMode, 
 | 
						|
                cmdExcInputFailDelayTime, cmdExcRefFailDelayTime }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Group for common exciter objects"
 | 
						|
            ::= { rsXx8000DvbTxGroups 23 }
 | 
						|
 | 
						|
        
 | 
						|
        groupExcAdditionalSx800 OBJECT-GROUP
 | 
						|
            OBJECTS { cmdExcRfOutputRegulation, cmdExcRfOutputManualRfLevel, cmdExcRfIqAdjustStart }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Additional exciter objects for the Sx800"
 | 
						|
            ::= { rsXx8000DvbTxGroups 24 }
 | 
						|
 | 
						|
        
 | 
						|
        groupExcAdditionalSLx OBJECT-GROUP
 | 
						|
            OBJECTS { cmdExcInput1Source, cmdExcInput2Source }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Additional exciter objects for the SLx and the Sx801"
 | 
						|
            ::= { rsXx8000DvbTxGroups 25 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsExciter NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txExcSummaryFault, txExcSummaryWarning, txExcInputNoConnectHP1, txExcInputNoConnectLP1, txExcInputNoConnectHP2, 
 | 
						|
                txExcInputNoConnectLP2, txExcInputActiveHP1, txExcInputActiveLP1, txExcInputActiveHP2, txExcInputActiveLP2, 
 | 
						|
                txExcOn, txExcRfOn, txExcNoInput, txExcRfLoop, txExcRfFail, 
 | 
						|
                txExcSelfTest, txExcOutputOpen, txExcBoardTemperatureWarning, txExcFanWarning, txExcFanFault, 
 | 
						|
                txExcFifoWarning, txExcTestSignal, txExcSFNDelay, txExcWrongDatarate, txExcMute, 
 | 
						|
                txExcPPSFail, txExcReferenceFail, txExcMIPFail, txExcInputAutomaticSwitchReady, txExcRfOk, 
 | 
						|
                txExcInputReseveMissing, txExcInputAutomaticChangedOver, txExcLocal }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "events from the exciter"
 | 
						|
            ::= { rsXx8000DvbTxGroups 26 }
 | 
						|
 | 
						|
        
 | 
						|
        groupExciterStatus OBJECT-GROUP
 | 
						|
            OBJECTS { excStatusRfOutputAgcRegulation, excStatusRfIqAdjustAuto, excStatusRfIqAdjustLO1Frequency, excStatusSfnDelayProcessing, excStatusSfnDelayDynamic, 
 | 
						|
                excStatusSfnDelayNetwork, excStatusSfnDelayTxOffset, excStatusSfnDelayMaximum, excStatusSfnDelayTotal, excStatusNominalPower
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Group for exciterStatusTable."
 | 
						|
            ::= { rsXx8000DvbTxGroups 27 }
 | 
						|
 | 
						|
        
 | 
						|
        groupExciterPrecorrection OBJECT-GROUP
 | 
						|
            OBJECTS { excPrecLinCorrection, excPrecLinAutomaticADE, excPrecLinMaxAmplitudeRipple, excPrecLinMaxGroupDelayRipple, excPrecLinAmplitudeRipple, 
 | 
						|
                excPrecLinGroupDelayRipple, excPrecLinInputLevel, excPrecLinAutomatic, excPrecNonlinCorrection, excPrecNonlinAutomaticADE, 
 | 
						|
                excPrecNonlinThresholdShoulders, excPrecNonlinShoulderLeft, excPrecNonlinShoulderRight, excPrecNonlinInputLevel, excPrecNonlinAutomatic
 | 
						|
                 }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Group for exciterPrecorrectionTable."
 | 
						|
            ::= { rsXx8000DvbTxGroups 28 }
 | 
						|
 | 
						|
        
 | 
						|
        groupSLx OBJECT-GROUP
 | 
						|
            OBJECTS { cmdExcTransmitterType, cmdExcTimeScheduler, excPrecUserState, excPrecFactoryState, excPrecRestoreCurrentSettings, 
 | 
						|
                excPrecRestoreAllSettings, configTvStandardName, configFrequency, configPower, schedulerRowStatus, 
 | 
						|
                schedulerEvent, schedulerDateTime, config2InputSource, config2Power, config2Frequency, 
 | 
						|
                config2RxFrequency, config2TvStandardName, excStatusVSWR, cmdExcMuteCondition, schedulerTvStandard, 
 | 
						|
                configRxFrequency, configInputSource }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "object types that are relevant for SLx devices only"
 | 
						|
            ::= { rsXx8000DvbTxGroups 29 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjectsACU OBJECT-GROUP
 | 
						|
            OBJECTS { cmdExcRfWarningLimit, cmdExcRfFailLimit, cmdExcOutputPower, cmdExcMonitoringOutput }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "objects from ACU"
 | 
						|
            ::= { rsXx8000DvbTxGroups 30 }
 | 
						|
 | 
						|
        
 | 
						|
        groupIndependentRacks OBJECT-GROUP
 | 
						|
            OBJECTS { rackReferenceVoltage, amplifiersPowerSupply, rackOnOff }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "object types that are relevant for NX variants with independent racks only"
 | 
						|
            ::= { rsXx8000DvbTxGroups 31 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjectsRE OBJECT-GROUP
 | 
						|
            OBJECTS { summaryFaultExcA }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "object types for the re-equip kit"
 | 
						|
            ::= { rsXx8000DvbTxGroups 32 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsControlExciter NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txNetCCUNoConnectionToExcB, txAutomaticExcReady, txAutomaticExcChanged, txAutomaticExcFault }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional events in case Sx801 is control exciter"
 | 
						|
            ::= { rsXx8000DvbTxGroups 34 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsAdditionalPowerSupply NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txInternalPowerSupplyWarning, txExternalPowerSupplyWarning }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Events that are available only when additionalPowerSupply is true."
 | 
						|
            ::= { rsXx8000DvbTxGroups 35 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjsAdditionalPowerSupply OBJECT-GROUP
 | 
						|
            OBJECTS { internalPowerSupply, externalPowerSupply }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Objects that are available only when additionalPowerSupply is true."
 | 
						|
            ::= { rsXx8000DvbTxGroups 36 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjectsControlExciter OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxOperationModeReserve, cmdTxOpModeExcAutomatic, cmdTxDelayTimeExcAutomatic, summaryFaultExcB, exciterAutomaticReady, 
 | 
						|
                exciterAutomaticChanged, exciterAutomaticFault, noConnectionExcB, activeExcB, cmdTxProgramExciterPrio, 
 | 
						|
                cmdTxChangeOver, cmdTxSwitchPosition }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "additional objects in case Sx801 is control exciter"
 | 
						|
            ::= { rsXx8000DvbTxGroups 37 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjectsSingleEnded OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxRfSwitch }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Group for objects in case of SingleTx or DualDrive."
 | 
						|
            ::= { rsXx8000DvbTxGroups 38 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObjectsSx801Amplifier OBJECT-GROUP
 | 
						|
            OBJECTS { sx801AmpRfOut, sx801AmpRfIn, sx801AmpReflection, sx801AmpOn, sx801AmpAC, 
 | 
						|
                sx801AmpCommunication, sx801AmpTransistor, sx801AmpDriver, sx801AmpTemperature, sx801AmpBlower, 
 | 
						|
                sx801AmpRegulation, sx801AmpUpdate, sx801Supply1Temperature, sx801Supply2Temperature, sx801SupplyRTemperature, 
 | 
						|
                sx801Supply1DC, sx801Supply2DC, sx801SupplyRDC, sx801AmpValueI1, sx801AmpValueI2, 
 | 
						|
                sx801AmpValueI3, sx801AmpValueI4, sx801AmpValueIPre, sx801AmpValueIDrv1, sx801AmpValueIDrv2, 
 | 
						|
                sx801AmpValuePowerOut, sx801AmpValueReflection, sx801AmpValueVRef, sx801AmpValueVReg, sx801AmpValueTemperature, 
 | 
						|
                sx801AmpValueMonAtt, sx801AmpValueVAux1, sx801AmpValueVAux2, sx801Supply1ValuePwr, sx801Supply2ValuePwr, 
 | 
						|
                sx801Supply1ValueDc, sx801Supply2ValueDc }
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Objects for Sx801/SA801 amplifier status."
 | 
						|
            ::= { rsXx8000DvbTxGroups 39 }
 | 
						|
 | 
						|
        
 | 
						|
        groupObsoleted OBJECT-GROUP
 | 
						|
            OBJECTS { cmdTxParametersetReSave, cmdExcTimeForDailyPcrReset, cmdExcEnablePcrReset, excInputAlpha, cmdExcTPSManualAlpha, 
 | 
						|
                rfProbeConfigurationLabel, cmdExcInputAutoSwitch }
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION 
 | 
						|
                "obsoleted or deprecated objects"
 | 
						|
            ::= { rsXx8000DvbTxGroups 99 }
 | 
						|
 | 
						|
        
 | 
						|
        groupEventsObsoleted NOTIFICATION-GROUP
 | 
						|
            NOTIFICATIONS { txParamSetSubDeviceDiffers, txNetCCUBoardTemperatureFault }
 | 
						|
            STATUS obsolete
 | 
						|
            DESCRIPTION 
 | 
						|
                "obsoleted or deprecated events"
 | 
						|
            ::= { rsXx8000DvbTxGroups 100 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DvbTxCompl OBJECT IDENTIFIER ::= { rsXx8000DvbTxConf 3 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBSingleTxMP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept SingleTransmitter for Medium Power."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupTxCommon, groupCommonMP, groupCommonNetCCU, groupExcCommon, groupEvents, 
 | 
						|
                    groupProductInfo, groupRfProbes, groupExciterStatus, groupExciterPrecorrection, groupEventsExciter, 
 | 
						|
                    groupEventsCommonNetCCU, groupObjectsSingleEnded, groupEventsCommonMP, groupEventsTxCommon }
 | 
						|
                GROUP groupIndependentRacks
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "for variant with independent racks only"
 | 
						|
                OBJECT cmdOstRefVoltageVision
 | 
						|
                    MIN-ACCESS not-accessible
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not accessible in variant with independent racks"
 | 
						|
                GROUP groupExcAdditionalSx800
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "in case of Sx800 exciter"
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupAmpMeasureValues
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupEventsAmplifier
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
            ::= { rsXx8000DvbTxCompl 1 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBDualDriveMP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept DualDrive for Medium Power."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupTxCommon, groupCommonMP, groupCommonNetCCU, groupExcCommon, groupDualDrive, 
 | 
						|
                    groupEvents, groupProductInfo, groupRfProbes, groupExciterStatus, groupExciterPrecorrection, 
 | 
						|
                    groupEventsExciter, groupEventsCommonNetCCU, groupEventsCommonMP, groupObjectsSingleEnded, groupEventsDualDrive, 
 | 
						|
                    groupEventsTxCommon }
 | 
						|
                GROUP groupIndependentRacks
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "for variant with independent racks only"
 | 
						|
                OBJECT cmdOstRefVoltageVision
 | 
						|
                    MIN-ACCESS not-accessible
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not accessible in variant with independent racks"
 | 
						|
                GROUP groupExcAdditionalSx800
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "in case of Sx800 exciter"
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupAmpMeasureValues
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupEventsAmplifier
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
            ::= { rsXx8000DvbTxCompl 2 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBPowerReserveMP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept Active/Passive Reserve for Medium Power."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupTxCommon, groupEvents, groupProductInfo, groupRfProbes, groupExciterStatus, 
 | 
						|
                    groupExcCommon, groupExciterPrecorrection, groupDualDrive, groupPowerReserve, groupCommonMP, 
 | 
						|
                    groupCommonNetCCU, groupOstBLogbook, groupEventsExciter, groupEventsCommonNetCCU, groupEventsCommonMP, 
 | 
						|
                    groupEventsPowerReserve, groupEventsDualDrive, groupEventsTxCommon }
 | 
						|
                GROUP groupIndependentRacks
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "for variant with independent racks only"
 | 
						|
                OBJECT cmdOstRefVoltageVision
 | 
						|
                    MIN-ACCESS not-accessible
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not accessible in variant with independent racks"
 | 
						|
                GROUP groupSumProbe
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "when sum probe exists only"
 | 
						|
                GROUP groupExcAdditionalSx800
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "in case of Sx800 exciter"
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupAmpMeasureValues
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupEventsAmplifier
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "not for face-lift configuration"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupDummyLoadRF
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when a dummy load measure point exists"
 | 
						|
            ::= { rsXx8000DvbTxCompl 3 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBSingleTxLP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept Low Power SingleTransmitter with NetCCU, meaning there is a NetCCU and a 
 | 
						|
                LowPower exciter with one or more (to the exciter) connected amplifiers."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, 
 | 
						|
                    groupCommonNetCCU, groupTxCommon, groupEventsExciter, groupEventsCommonNetCCU, groupEventsTxCommon
 | 
						|
                     }
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
            ::= { rsXx8000DvbTxCompl 5 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBDualDriveLP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept DualDrive for Low Power."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, 
 | 
						|
                    groupCommonNetCCU, groupDualDrive, groupTxCommon, groupEventsExciter, groupEventsCommonNetCCU, 
 | 
						|
                    groupEventsDualDrive, groupEventsTxCommon }
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
            ::= { rsXx8000DvbTxCompl 6 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBPowerReserveLP MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept Active/Passive Reserve for Low Power."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, 
 | 
						|
                    groupCommonNetCCU, groupPowerReserve, groupDualDrive, groupTxCommon, groupEventsExciter, 
 | 
						|
                    groupEventsCommonNetCCU, groupEventsPowerReserve, groupEventsDualDrive, groupEventsTxCommon }
 | 
						|
                GROUP groupEventsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
                GROUP groupObjsAdditionalPowerSupply
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "only when additionalPowerSupply is true"
 | 
						|
            ::= { rsXx8000DvbTxCompl 7 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBSingleTxLPNoNetCCU MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Reserve concept Low Power SingleTransmitter without NetCCU, meaning there is only a
 | 
						|
                LowPower exciter with one or more (to the exciter) connected amplifiers."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, 
 | 
						|
                    groupTxCommon, groupEventsExciter, groupEventsTxCommon }
 | 
						|
            ::= { rsXx8000DvbTxCompl 9 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBSLx MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "SLx device"
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupSLx, groupObjectsACU, 
 | 
						|
                    groupExcCommon, groupTxCommon, groupEventsExciter, groupEventsTxCommon }
 | 
						|
            ::= { rsXx8000DvbTxCompl 10 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBExciterOnly MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "DVB Exciter of 8000 series in a 7000 environment
 | 
						|
                or
 | 
						|
                Program Exciter in a Sx801 Backup Exciter environment."
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupProductInfo, groupExciterStatus, groupEvents, groupObjectsRE, groupObjectsSx801Amplifier, 
 | 
						|
                    groupExciterPrecorrection, groupExcCommon, groupEventsExciter }
 | 
						|
                GROUP groupSLx
 | 
						|
                    DESCRIPTION 
 | 
						|
                        "in case of SLx device"
 | 
						|
            ::= { rsXx8000DvbTxCompl 11 }
 | 
						|
 | 
						|
        
 | 
						|
        rsXx8000DVBSx801ControlExciter MODULE-COMPLIANCE
 | 
						|
            STATUS current
 | 
						|
            DESCRIPTION 
 | 
						|
                "Sx801 as control exciter"
 | 
						|
            MODULE -- this module
 | 
						|
                MANDATORY-GROUPS { groupTxCommon, groupExcCommon, groupEvents, groupExciterStatus, groupExciterPrecorrection, 
 | 
						|
                    groupSLx, groupObjectsACU, groupObjectsSx801Amplifier, groupEventsExciter, groupEventsTxCommon, 
 | 
						|
                    groupEventsControlExciter, groupObjectsControlExciter }
 | 
						|
            ::= { rsXx8000DvbTxCompl 12 }
 | 
						|
 | 
						|
        
 | 
						|
    
 | 
						|
    END
 |