--  SIAE MICROELETTRONICA s.p.a.
 | 
						|
--
 | 
						|
--  Via Michelangelo Buonarroti, 21
 | 
						|
--  20093 - Cologno Monzese
 | 
						|
--  Milano
 | 
						|
--  ITALY
 | 
						|
--
 | 
						|
-- ----------------------------------------------------------------------------
 | 
						|
-- ----------------------------------------------------------------------------
 | 
						|
 | 
						|
SIAE-SFP-MIB
 | 
						|
        DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
        IMPORTS
 | 
						|
             MODULE-IDENTITY, OBJECT-TYPE,
 | 
						|
             Integer32
 | 
						|
        FROM SNMPv2-SMI
 | 
						|
             TEXTUAL-CONVENTION,
 | 
						|
             DisplayString, TruthValue
 | 
						|
        FROM SNMPv2-TC
 | 
						|
             siaeMib
 | 
						|
        FROM SIAE-TREE-MIB
 | 
						|
             AlarmStatus, AlarmSeverityCode
 | 
						|
        FROM SIAE-ALARM-MIB;
 | 
						|
 | 
						|
    sfp MODULE-IDENTITY
 | 
						|
        LAST-UPDATED "201612150000Z"
 | 
						|
        ORGANIZATION "SIAE MICROELETTRONICA spa"
 | 
						|
        CONTACT-INFO
 | 
						|
            "SIAE MICROELETTONICA s.p.a.
 | 
						|
             Via Michelangelo Buonarroti, 21
 | 
						|
             20093 - Cologno Monzese
 | 
						|
             Milano - ITALY
 | 
						|
             Phone :  +39-02-27325-1
 | 
						|
             E-mail: info@siaemic.com
 | 
						|
            "
 | 
						|
        DESCRIPTION
 | 
						|
            " This MIB contains objects & alarms for a SFP
 | 
						|
              (Small Form-Factor Pluggable) module.
 | 
						|
              Reference documentation:
 | 
						|
               1) Small Form-factor Pluggable (SFP) Transceiver MultiSource
 | 
						|
                  Agreement (MSA)
 | 
						|
               2) Finisar's Application Note AN-2030, Rev. D.
 | 
						|
               3) SFF 8472 - Diagnostic Monitoring Interface for Optical 
 | 
						|
                             Transceivers
 | 
						|
                             Rev 12.2 November 21, 2014
 | 
						|
               4) SFF 8024 - SFF Cross Reference to Industry Products
 | 
						|
                             Rev 4.0 June 27, 2016
 | 
						|
            "
 | 
						|
        REVISION "201612150000Z"
 | 
						|
        DESCRIPTION
 | 
						|
            "MIB version 01.00.02
 | 
						|
             - Added TEXTUAL-CONVENTION Temperature and PhysicalQuantity
 | 
						|
             - Added sfpAlarmTable, sfpDiagnosticTable, sfpHighAlarmSeverityCode,
 | 
						|
               sfpHighWarningAlarmSeverityCode, sfpLowWarningAlarmSeverityCode
 | 
						|
               and sfpLowWarningAlarmSeverityCode
 | 
						|
            "
 | 
						|
        REVISION "201609290000Z"
 | 
						|
        DESCRIPTION
 | 
						|
            "MIB version 01.00.01
 | 
						|
             - Added sfpBasePX, sfpBaseBX10, sfp100BaseFX, sfp100BaseLX to
 | 
						|
               sfpCompliance
 | 
						|
            "
 | 
						|
        REVISION "201402030000Z"
 | 
						|
        DESCRIPTION
 | 
						|
            "Improved description of sfpMibVersion
 | 
						|
            "
 | 
						|
        REVISION "201312050000Z"
 | 
						|
        DESCRIPTION
 | 
						|
            "Initial version 01.00.00
 | 
						|
            "
 | 
						|
      ::= { siaeMib 74 }
 | 
						|
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
--  Textual Conventions
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
 | 
						|
 | 
						|
    Temperature ::= TEXTUAL-CONVENTION
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Temperature in tenth of degrees C"
 | 
						|
        SYNTAX        Integer32 (-2000..2000)
 | 
						|
 | 
						|
    PhysicalQuantity ::= TEXTUAL-CONVENTION
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity"
 | 
						|
        SYNTAX        INTEGER {
 | 
						|
                                phyQtTemperature  (1),
 | 
						|
                                phyQtVoltage      (2),
 | 
						|
                                phyQtTxBias       (3),
 | 
						|
                                phyQtTxPower      (4),
 | 
						|
                                phyQtRxPower      (5)
 | 
						|
                              }
 | 
						|
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
--  object identifier inside the module
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
--  sfp GROUP
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
--
 | 
						|
-- This group is used to manage Small Form-Factor Pluggable Modules
 | 
						|
--
 | 
						|
----------------------------------------------------------------------------------
 | 
						|
 | 
						|
------ Beginning --------------------------------------------------------------
 | 
						|
 | 
						|
    sfpMibVersion  OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Numerical version of this module.
 | 
						|
             The string version of this MIB have the following format:
 | 
						|
                XX.YY.ZZ
 | 
						|
             so, for example, the value 1 should be interpreted as 00.00.01
 | 
						|
             and the value 10001 should be interpreted as 01.00.01."
 | 
						|
        DEFVAL {1}
 | 
						|
    ::= {sfp 1}
 | 
						|
 | 
						|
-------  Begin of sfpModuleTable
 | 
						|
--
 | 
						|
    sfpSerialIdTable  OBJECT-TYPE
 | 
						|
        SYNTAX      SEQUENCE OF     SfpSerialIdEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
             "Each SFP contains a 95+32 byte block of ID data fields.
 | 
						|
              This table contains the items found in this data block.
 | 
						|
              Fields in this data block is filled in by the SFP manufactor.
 | 
						|
              The table shows the contents of this data block without further
 | 
						|
              processing."
 | 
						|
    ::= {sfp 2}
 | 
						|
 | 
						|
    sfpSerialIdEntry  OBJECT-TYPE
 | 
						|
        SYNTAX      SfpSerialIdEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "SFP module record."
 | 
						|
        INDEX       { sfpModuleId }
 | 
						|
    ::= {sfpSerialIdTable 1}
 | 
						|
 | 
						|
    SfpSerialIdEntry  ::=
 | 
						|
        SEQUENCE {
 | 
						|
            sfpModuleId             Integer32,
 | 
						|
            sfpSerialIdValid        TruthValue,
 | 
						|
            sfpVendorName           OCTET STRING,
 | 
						|
            sfpVendorPartNumber     OCTET STRING,
 | 
						|
            sfpVendorRev            OCTET STRING,
 | 
						|
            sfpVendorSN             OCTET STRING,
 | 
						|
            sfpVendorDateCode       OCTET STRING,
 | 
						|
            sfpDiagMonitorCode      BITS,
 | 
						|
            sfpEnhancedOptionsCode  BITS,
 | 
						|
            sfpOptions              BITS,
 | 
						|
            sfpFibreChannelMedia    BITS,
 | 
						|
            sfpCompliance           BITS,
 | 
						|
            sfpWavelength           Integer32,
 | 
						|
            sfpNominalBitRate       Integer32,
 | 
						|
            sfpLinkLength9u         Integer32,
 | 
						|
            sfpLinkLength50u        Integer32,
 | 
						|
            sfpLinkLength62u5       Integer32,
 | 
						|
            sfpLinkLengthCopper     Integer32,
 | 
						|
            sfpLabel                DisplayString,
 | 
						|
            sfpFailAlarm            AlarmStatus
 | 
						|
         }
 | 
						|
 | 
						|
    sfpModuleId OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This index identifies a unique SFP module in the system"
 | 
						|
    ::= {sfpSerialIdEntry 1}
 | 
						|
 | 
						|
    sfpSerialIdValid OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "When false the SFP data in this table is not valid. This
 | 
						|
             will be set to False if the SFP module is not installed or if
 | 
						|
             the EEPROM check code is wrong. The data in this table should
 | 
						|
             not be used unless this element is True."
 | 
						|
    ::= {sfpSerialIdEntry 2}
 | 
						|
 | 
						|
    sfpVendorName OBJECT-TYPE
 | 
						|
        SYNTAX        OCTET STRING (SIZE(0..16))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "The SFP vendor name.
 | 
						|
             Located at I2C address 0xa0, bytes: 20 - 35"
 | 
						|
    ::= {sfpSerialIdEntry 3}
 | 
						|
 | 
						|
    sfpVendorPartNumber OBJECT-TYPE
 | 
						|
        SYNTAX        OCTET STRING (SIZE(0..16))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "The SFP vendor part number.
 | 
						|
             Located at I2C address 0xa0, bytes: 40 - 55"
 | 
						|
    ::= {sfpSerialIdEntry 4}
 | 
						|
 | 
						|
    sfpVendorRev OBJECT-TYPE
 | 
						|
        SYNTAX        OCTET STRING (SIZE(0..4))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "The SFP vendor's product revision number.
 | 
						|
             Located at I2C address 0xa0, bytes: 56 - 59"
 | 
						|
    ::= {sfpSerialIdEntry 5}
 | 
						|
 | 
						|
    sfpVendorSN OBJECT-TYPE
 | 
						|
        SYNTAX        OCTET STRING (SIZE(0..16))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "The SFP vendor serial number.
 | 
						|
             Located at I2C address 0xa0, bytes: 68 - 83"
 | 
						|
    ::= {sfpSerialIdEntry 6}
 | 
						|
 | 
						|
    sfpVendorDateCode OBJECT-TYPE
 | 
						|
        SYNTAX        OCTET STRING (SIZE(0..8))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "The SFP vendor date code.
 | 
						|
             Format: YYMMDDLL
 | 
						|
                     - YY: year,  00 = 2000
 | 
						|
                     - MM: month, 01 = January
 | 
						|
                     - DD_ day,   01 to 31
 | 
						|
                     - LL: vendor lot code, or blank.
 | 
						|
             Located at I2C address 0xa0, bytes: 84 - 91"
 | 
						|
    ::= {sfpSerialIdEntry 7}
 | 
						|
 | 
						|
    sfpDiagMonitorCode OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            -- must be 0
 | 
						|
            sfpDMCtypeLegacy(0),
 | 
						|
            -- Digital Diagnostic monitoring is implemented
 | 
						|
            sfpDMCtypeImplemented(1),
 | 
						|
            -- Internally Calibrated
 | 
						|
            sfpDMCtypeInternalCal(2),
 | 
						|
            -- Externally Calibrated
 | 
						|
            sfpDMCtypeExternalCal(3),
 | 
						|
            -- Rx Power Meas. Type, 0=OMA, 1=Average
 | 
						|
            sfpDMCtypeRxAvgPwr(4),
 | 
						|
            -- Special Addressing required
 | 
						|
            sfpDMCtypeAddrChngReqrd(5)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This indicates which type of diagnostic monitoring is
 | 
						|
             implemented (if any) in the SFP.
 | 
						|
             -bit 7: = 0 legacy diagnostic implementations (should be 0)
 | 
						|
             -bit 6: = 1 digital diagnostic monitoring implemented (should be 1)
 | 
						|
             -bit 5: = 1 internal calibration
 | 
						|
             -bit 4: = 1 external calibration mask
 | 
						|
             -bit 3: = 0 OMA received power measurment,
 | 
						|
                     = 1 average received power
 | 
						|
             -bit 2: = 1 I2C addressing option.
 | 
						|
             Located at I2C address 0xa0, byte: 92"
 | 
						|
    ::= {sfpSerialIdEntry 8}
 | 
						|
 | 
						|
    sfpEnhancedOptionsCode OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            -- Alarms & Warnings are implemented
 | 
						|
            sfpEOCalarmsImplemented(0),
 | 
						|
            -- Soft TX_DISABLE is implemented
 | 
						|
            sfpEOCSoftTxDisable(1),
 | 
						|
            -- Soft TX_FAULT is implemented
 | 
						|
            sfpEOCSoftTxFault(2),
 | 
						|
            -- Soft RX_LOS is implemented
 | 
						|
            sfpEOCSoftRxLOS(3),
 | 
						|
            -- Soft RATE_SELECT is implemented
 | 
						|
            sfpEOCSoftRateSelect(4)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This indicates which optional enhanced features are
 | 
						|
             implemented (if any) in the SFP.
 | 
						|
             Located at I2C address 0xa0, byte: 93"
 | 
						|
    ::= {sfpSerialIdEntry 9}
 | 
						|
 | 
						|
    sfpOptions OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            -- RATE_SELECT is implemented
 | 
						|
            sfpOPTRateSelect(0),
 | 
						|
            -- TX_DISABLE is implemented
 | 
						|
            sfpOPTTxDisable(1),
 | 
						|
            -- TX_FAULT is implemented
 | 
						|
            sfpOPTTxFault(2),
 | 
						|
            -- LOS implemented but inverted
 | 
						|
            sfpOPTInvertedLOS(3),
 | 
						|
            -- LOS implemented
 | 
						|
            sfpOPTlos(4)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Implemented transceiver options:
 | 
						|
             -bit 5: = 1 RATE_SELECT implemented.
 | 
						|
             -bit 4: = 1 TX_DISABLE implemented
 | 
						|
             -bit 3: = 1 TX_FAULT implemented
 | 
						|
             -bit 2: = 1 LOS Implemented, inverted
 | 
						|
             -bit 1: = 1 LOS Implemented
 | 
						|
             Located at I2C address 0xa0, byte: 65"
 | 
						|
    ::= {sfpSerialIdEntry 10}
 | 
						|
 | 
						|
    sfpFibreChannelMedia OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            -- Multi-mode 62.5 micron (M6): byte 9 bit 3
 | 
						|
            sfpMultiMode62u5(0),
 | 
						|
            -- Multi-mode 50.0 micron (M5): byte 9 bit 2
 | 
						|
            sfpMultiMode50u0(1),
 | 
						|
            -- Single mode (SM): byte 9 bit 0
 | 
						|
            sfpSingleMode(2),
 | 
						|
            -- Twin Axial Pair (TW): byte 9 bit 7
 | 
						|
            sfpTwistedAxialPair(3),
 | 
						|
            -- Shielded Twisted Pair (TP): byte 9 bit 6
 | 
						|
            sfpShieldedTwistedPair(4),
 | 
						|
            -- Miniature Coax (MI): byte 9 bit 5
 | 
						|
            sfpMiniatureCoax(5),
 | 
						|
            -- Video Coax (TV): byte 9 bit 4
 | 
						|
            sfpVideoCoax(6)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Fiber Channel transmission media.
 | 
						|
             Located at I2C address 0xa0, byte: 9"
 | 
						|
    ::= {sfpSerialIdEntry 11}
 | 
						|
 | 
						|
 | 
						|
    sfpCompliance OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            -- SONET reach specifier bit 1: byte 4 bit 4
 | 
						|
            sfpSonetReachSpecifier1(0),
 | 
						|
            -- SONET reach specifier bit 1: byte 4 bit 3
 | 
						|
            sfpSonetReachSpecifier2(1),
 | 
						|
            -- OC48 long reach: byte 4 bit 2
 | 
						|
            sfpSonetOC48LongReach(2),
 | 
						|
            -- OC48 intermediate reach: byte 4 bit 1
 | 
						|
            sfpSonetOC48IntermediateReach(3),
 | 
						|
            -- OC48 short reach: byte 4 bit 0
 | 
						|
            sfpSonetOC48ShortReach(4),
 | 
						|
            -- OC-12 long reach: byte 5 bit 6
 | 
						|
            sfpSonetOC12LongReach(5),
 | 
						|
            -- OC-12 intermediate reach: byte 5 bit 5
 | 
						|
            sfpSonetOC12IntermediateReach(6),
 | 
						|
            -- OC-12 short reach: byte 5 bit 4
 | 
						|
            sfpSonetOC12ShortReach(7),
 | 
						|
            -- OC-3 long reach: byte 5 bit 2
 | 
						|
            sfpSonetOC3LongReach(8),
 | 
						|
            -- OC-3 intermediate reach: byte 5 bit 1
 | 
						|
            sfpSonetOC3IntermediateReach(9),
 | 
						|
            -- OC-3 short reach: byte 5 bit 0
 | 
						|
            sfpSonetOC3ShortReach(10),
 | 
						|
            -- 1000base-T: byte 6 bit 3
 | 
						|
            sfp1000BaseT(11),
 | 
						|
            -- 1000base-CX: byte 6 bit 2
 | 
						|
            sfp1000BaseCX(12),
 | 
						|
            -- 1000base-LX: byte 6 bit 1
 | 
						|
            sfp1000BaseLX(13),
 | 
						|
            -- 1000base-SX: byte 6 bit 0
 | 
						|
            sfp1000baseSX(14),
 | 
						|
            -- base-PX: byte 6 bit 7
 | 
						|
            sfpBasePX(15),
 | 
						|
            -- base-BX10: byte 6 bit 6
 | 
						|
            sfpBaseBX10(16),
 | 
						|
            -- 100base-FX: byte 6 bit 5
 | 
						|
            sfp100BaseFX(17),
 | 
						|
            -- 100base-LX/LX10: byte 6 bit 4
 | 
						|
            sfp100BaseLX(18)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Electronic or optical interfaces that are supported by the
 | 
						|
             transceiver.
 | 
						|
             Located at I2C address 0xa0, bytes: 4,5 & 6"
 | 
						|
    ::= {sfpSerialIdEntry 12}
 | 
						|
 | 
						|
    sfpWavelength OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        UNITS         "nm"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Nominal transmiter output wavelength at room temperature.
 | 
						|
             Units are in nm (nanometers).
 | 
						|
             Located at I2C address 0xa0, bytes: 60 & 61 (endianess: big)"
 | 
						|
    ::= {sfpSerialIdEntry 13}
 | 
						|
 | 
						|
    sfpNominalBitRate OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Nominal bit rate (in megabit per second) supported from this
 | 
						|
             SFP module rouded to the nearest 100 megabits per second.
 | 
						|
             Located at I2C address 0xa0, byte: 12"
 | 
						|
    ::= {sfpSerialIdEntry 14}
 | 
						|
 | 
						|
    sfpLinkLength9u OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        UNITS       "m"
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Link length (in meters) supported from this SFP module while
 | 
						|
             operating in compliance with the applicable standards using single
 | 
						|
             mode fiber. A value of zero means that the transceiver does not
 | 
						|
             support single mode fiber.
 | 
						|
             Located at I2C address 0xa0, bytes: 14-15"
 | 
						|
    ::= {sfpSerialIdEntry 15}
 | 
						|
 | 
						|
    sfpLinkLength50u OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        UNITS       "m"
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Link length (in meters) supported from this SFP module while
 | 
						|
             operating in compliance with the applicable standards using
 | 
						|
             50 micron multi-mode fiber. A value of zero means that the
 | 
						|
             transceiver does not support 50 micron multi-mode mode fiber.
 | 
						|
             Located at I2C address 0xa0, byte: 16"
 | 
						|
    ::= {sfpSerialIdEntry 16}
 | 
						|
 | 
						|
    sfpLinkLength62u5 OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        UNITS       "m"
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Link length (in meters) supported from this SFP module while
 | 
						|
             operating in compliance with the applicable standards using
 | 
						|
             62.5 micron multi-mode fiber. A value of zero means that the
 | 
						|
             transceiver does not support 62.5 micron multi-mode mode fiber.
 | 
						|
             Located at I2C address 0xa0, byte: 17"
 | 
						|
    ::= {sfpSerialIdEntry 17}
 | 
						|
 | 
						|
    sfpLinkLengthCopper OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        UNITS       "m"
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Link length (in meters) supported from this SFP module while
 | 
						|
             operating in compliance with the applicable standards using
 | 
						|
             copper cable. A value of zero means that the transceiver does
 | 
						|
             not support copper cable.
 | 
						|
             Located at I2C address 0xa0, byte: 18"
 | 
						|
    ::= {sfpSerialIdEntry 18}
 | 
						|
 | 
						|
    sfpLabel OBJECT-TYPE
 | 
						|
        SYNTAX        DisplayString (SIZE(0..32))
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This is an ASCII string that identifies this SFP in the
 | 
						|
             system."
 | 
						|
    ::= {sfpSerialIdEntry 19}
 | 
						|
 | 
						|
    sfpFailAlarm  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmStatus
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "SFP Module fail (module missing included)"
 | 
						|
    ::= {sfpSerialIdEntry 20}
 | 
						|
 | 
						|
--
 | 
						|
-------  End of sfpModuleTable
 | 
						|
 | 
						|
    sfpFailAlarmSeverityCode  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmSeverityCode
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Defines the severity associated to the sfpFailAlarm
 | 
						|
             and enables/disables the trap generation on status change event."
 | 
						|
        DEFVAL {majorTrapEnable}
 | 
						|
    ::= {sfp 6}
 | 
						|
 | 
						|
-------  Begin of sfpDiagnosticTable
 | 
						|
--
 | 
						|
    sfpDiagnosticTable OBJECT-TYPE
 | 
						|
        SYNTAX        SEQUENCE OF SfpDiagnosticEntry
 | 
						|
        MAX-ACCESS    not-accessible
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Each SFP may contain a 256 byte block of diagnostic data
 | 
						|
             fields. This table contains the items found in this data block.
 | 
						|
             The data block is located at I2C address 0xa2."
 | 
						|
        ::= { sfp 7 }
 | 
						|
 | 
						|
    sfpDiagnosticEntry OBJECT-TYPE
 | 
						|
        SYNTAX        SfpDiagnosticEntry
 | 
						|
        MAX-ACCESS    not-accessible
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This describes a row in the diagnostic table."
 | 
						|
        INDEX         { sfpModuleId }
 | 
						|
        ::= { sfpDiagnosticTable 1 }
 | 
						|
 | 
						|
    SfpDiagnosticEntry ::= SEQUENCE
 | 
						|
    {
 | 
						|
        sfpDiagnosticValid  TruthValue,
 | 
						|
        sfpLOSPinOut        TruthValue,
 | 
						|
        sfpTxFaultPinOut    TruthValue,
 | 
						|
        sfpRateSelectPinIn  TruthValue,
 | 
						|
        sfpTxDisablePinIn   TruthValue,
 | 
						|
        sfpTemperature      Temperature,
 | 
						|
        sfpVoltage          Integer32,
 | 
						|
        sfpTxBias           Integer32,
 | 
						|
        sfpTxPower          Integer32,
 | 
						|
        sfpRxPower          Integer32,
 | 
						|
        sfpInternalAlarms   BITS,
 | 
						|
        sfpInternalWarnings BITS
 | 
						|
    }
 | 
						|
 | 
						|
    sfpDiagnosticValid OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "if False, then the SFP data in this table is not valid. This
 | 
						|
             will be set to False if the SFP module is not installed, or if
 | 
						|
             the I/O card that contains the SFP is not installed or if
 | 
						|
             the EEPROM check code is wrong. The data in the table should
 | 
						|
             not be used unless this element is True."
 | 
						|
        ::= { sfpDiagnosticEntry 1 }
 | 
						|
 | 
						|
    sfpLOSPinOut OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the T/F state of the SFP LOS (output) pin. It is
 | 
						|
             True if the SFP has detected Loss-Of-Signal. located at I2c
 | 
						|
             address 0xa2, address: 110, mask 0x02"
 | 
						|
        ::= { sfpDiagnosticEntry 2 }
 | 
						|
 | 
						|
    sfpTxFaultPinOut OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the T/F state of the SFP Tx Fault (output) pin.
 | 
						|
             It is True if the SFP has detected a Tx fault condition.
 | 
						|
             located at I2C address 0xa2, Byte 110, mask 0x04"
 | 
						|
        ::= { sfpDiagnosticEntry 3 }
 | 
						|
 | 
						|
    sfpRateSelectPinIn OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the T/F state of the SFP RX Rate Select (input)
 | 
						|
             pin. This function is not implemented on Finisar SFPs. located
 | 
						|
             at I2C address 0xa2, Byte 110, mask 0x10"
 | 
						|
        ::= { sfpDiagnosticEntry 4 }
 | 
						|
 | 
						|
    sfpTxDisablePinIn OBJECT-TYPE
 | 
						|
        SYNTAX        TruthValue
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the T/F state of the SFP TX Disable (input) pin.
 | 
						|
             located at I2C address 0xa2, Byte 110, mask 0x80"
 | 
						|
        ::= { sfpDiagnosticEntry 5 }
 | 
						|
 | 
						|
    sfpTemperature OBJECT-TYPE
 | 
						|
        SYNTAX        Temperature
 | 
						|
        UNITS         "C/10"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the internal temperature of the SFP in tehnth of 
 | 
						|
             Celsius degrees. Range is from -128.0C to +128.0C, but is only
 | 
						|
             valid from -40.0C to +125.0C with an accuracy of +/- 3C. 
 | 
						|
             Located at I2C address 0xa2, Bytes 96 & 97 (MSB, LSB)"
 | 
						|
        ::= { sfpDiagnosticEntry 6 }
 | 
						|
 | 
						|
    sfpVoltage OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32 (0..65535)
 | 
						|
        UNITS         "milliVolts (mV)"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the internally measured SFP supply voltage
 | 
						|
             (Vcc). Units are in milliVolts (3210 = 3.21V). Range is 0 to
 | 
						|
             6.554V. Located at I2C address 0xa2, Bytes 98 & 99 (MSB, LSB)"
 | 
						|
        ::= { sfpDiagnosticEntry 7 }
 | 
						|
 | 
						|
    sfpTxBias OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32 (0..131000)
 | 
						|
        UNITS         "microAmps (uA)"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the internally measured SFP TX laser bias
 | 
						|
             current. Units are in microAmps, and range from 0 to 131000uA
 | 
						|
             (131mA). Located at I2C address 0xa2, Bytes 100 & 101 (MSB, LSB)"
 | 
						|
        ::= { sfpDiagnosticEntry 8 }
 | 
						|
 | 
						|
    sfpTxPower OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32 (0..65535)
 | 
						|
        UNITS         "microWatts (uW)"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the internally measured TX output power. Units
 | 
						|
             are in uW (micro Watts), and range from 0 to 6554uW (6.535mW).
 | 
						|
             This value is not valid if the transmitter is disabled. Located
 | 
						|
             at I2C address 0xa2, Bytes 102 & 103 (MSB, LSB)"
 | 
						|
        ::= { sfpDiagnosticEntry 9 }
 | 
						|
 | 
						|
    sfpRxPower OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32 (0..65535)
 | 
						|
        UNITS         "microWatts (uW)"
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the internally measured RX optical power. Units
 | 
						|
             are in uW (micro Watts), and range from 0 to 6554uW (6.535mW).
 | 
						|
             Located at I2C address 0xa2, Bytes 104 & 105 (MSB, LSB)"
 | 
						|
        ::= { sfpDiagnosticEntry 10 }
 | 
						|
 | 
						|
    sfpInternalAlarms OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            sfpIntAlarmTempHigh(0),
 | 
						|
            sfpIntAlarmTempLow(1),
 | 
						|
            sfpIntAlarmVoltageHigh(2),
 | 
						|
            sfpIntAlarmVoltageLow(3),
 | 
						|
            sfpIntAlarmTxBiasHigh(4),
 | 
						|
            sfpIntAlarmTxBiasLow(5),
 | 
						|
            sfpIntAlarmTxPowerHigh(6),
 | 
						|
            sfpIntAlarmTxPowerLow(7),
 | 
						|
            sfpIntAlarmRxPowerHigh(8),
 | 
						|
            sfpIntAlarmRxPowerLow(9)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the state of the SFP internal alarm register. A
 | 
						|
             bit is set for each alarm that is active. located at I2C
 | 
						|
             address 0xa2, Byte 112 & 113  (MSB, LSB) mask 0xffc0"
 | 
						|
        ::= { sfpDiagnosticEntry 11 }
 | 
						|
 | 
						|
    sfpInternalWarnings OBJECT-TYPE
 | 
						|
        SYNTAX        BITS {
 | 
						|
            sfpIntWarnTempHigh(0),
 | 
						|
            sfpIntWarnTempLow(1),
 | 
						|
            sfpIntWarnVoltageHigh(2),
 | 
						|
            sfpIntWarnVoltageLow(3),
 | 
						|
            sfpIntWarnTxBiasHigh(4),
 | 
						|
            sfpIntWarnTxBiasLow(5),
 | 
						|
            sfpIntWarnTxPowerHigh(6),
 | 
						|
            sfpIntWarnTxPowerLow(7),
 | 
						|
            sfpIntWarnRxPowerHigh(8),
 | 
						|
            sfpIntWarnRxPowerLow(9)
 | 
						|
        }
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This contains the state of the SFP internal warning register.
 | 
						|
             A bit is set for each warning that is active. located at I2C
 | 
						|
             address 0xa2, Byte 116 & 117  (MSB, LSB) mask 0xffc0"
 | 
						|
        ::= { sfpDiagnosticEntry 12 }
 | 
						|
 | 
						|
--
 | 
						|
-------  End of sfpDiagnosticTable
 | 
						|
 | 
						|
-------  Begin of sfpAlarmTable
 | 
						|
--
 | 
						|
    sfpAlarmTable OBJECT-TYPE
 | 
						|
        SYNTAX        SEQUENCE OF SfpAlarmEntry
 | 
						|
        MAX-ACCESS    not-accessible
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "This table contains the SFP alarm and warning threshold
 | 
						|
             values."
 | 
						|
        ::= { sfp 10 }
 | 
						|
 | 
						|
    sfpAlarmEntry OBJECT-TYPE
 | 
						|
        SYNTAX        SfpAlarmEntry
 | 
						|
        MAX-ACCESS    not-accessible
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "An entry into the Threshold table."
 | 
						|
        INDEX         { sfpModuleId, sfpPhysicalQuantity }
 | 
						|
        ::= { sfpAlarmTable 1 }
 | 
						|
 | 
						|
    SfpAlarmEntry ::= SEQUENCE
 | 
						|
    {
 | 
						|
        sfpPhysicalQuantity            PhysicalQuantity,
 | 
						|
        sfpThresholdHighAlarm          Integer32,
 | 
						|
        sfpThresholdHighWarning        Integer32,
 | 
						|
        sfpThresholdLowAlarm           Integer32,
 | 
						|
        sfpThresholdLowWarning         Integer32,
 | 
						|
        sfpHighAlarm                   AlarmStatus,
 | 
						|
        sfpHighWarningAlarm            AlarmStatus,
 | 
						|
        sfpLowAlarm                    AlarmStatus,
 | 
						|
        sfpLowWarningAlarm             AlarmStatus
 | 
						|
    }
 | 
						|
 | 
						|
    sfpPhysicalQuantity OBJECT-TYPE
 | 
						|
        SYNTAX        PhysicalQuantity
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity.
 | 
						|
             Units of temperature are tenth of Celsius degrres,
 | 
						|
             units of Power supply voltage (Vcc) are microVolts,
 | 
						|
             units of Tx laser bias current are microAmps (uA),
 | 
						|
             units of Rx optical power are microWatts (uW),
 | 
						|
             units of Tx output power are microWatts (uW).
 | 
						|
            "
 | 
						|
        ::= { sfpAlarmEntry 1 }
 | 
						|
 | 
						|
    sfpThresholdHighAlarm OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "A reading at or above this temperature will trigger a high
 | 
						|
             measured physical quantity alarm."
 | 
						|
        ::= { sfpAlarmEntry 2 }
 | 
						|
 | 
						|
    sfpThresholdHighWarning OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "A reading at or above this temperature will trigger a high
 | 
						|
             measured physical quantity warning."
 | 
						|
        ::= { sfpAlarmEntry 3 }
 | 
						|
 | 
						|
    sfpThresholdLowAlarm OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "A reading at or above this temperature will trigger a low
 | 
						|
             measured physical quantity alarm."
 | 
						|
        ::= { sfpAlarmEntry 4 }
 | 
						|
 | 
						|
    sfpThresholdLowWarning OBJECT-TYPE
 | 
						|
        SYNTAX        Integer32
 | 
						|
        MAX-ACCESS    read-only
 | 
						|
        STATUS        current
 | 
						|
        DESCRIPTION
 | 
						|
            "A reading at or above this temperature will trigger a low
 | 
						|
             measured physical quantity warning."
 | 
						|
        ::= { sfpAlarmEntry 5 }
 | 
						|
 | 
						|
    sfpHighAlarm  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmStatus
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity has crossed sfpThresholdHighAlarm."
 | 
						|
        ::= {sfpAlarmEntry 6}
 | 
						|
 | 
						|
    sfpHighWarningAlarm  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmStatus
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity has crossed sfpThresholdHighWarning."
 | 
						|
        ::= {sfpAlarmEntry 7}
 | 
						|
 | 
						|
    sfpLowAlarm  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmStatus
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity has crossed sfpThresholdLowAlarm."
 | 
						|
        ::= {sfpAlarmEntry 8}
 | 
						|
 | 
						|
    sfpLowWarningAlarm  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmStatus
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Measured physical quantity has crossed sfpThresholdLowWarning."
 | 
						|
        ::= {sfpAlarmEntry 9}
 | 
						|
 | 
						|
--
 | 
						|
-------  End of sfpAlarmTable
 | 
						|
 | 
						|
    sfpHighAlarmSeverityCode  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmSeverityCode
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Defines the severity associated to the sfpHighAlarm
 | 
						|
             and enables/disables the trap generation on status change event."
 | 
						|
        DEFVAL {majorTrapEnable}
 | 
						|
    ::= {sfp 11}
 | 
						|
 | 
						|
    sfpHighWarningAlarmSeverityCode  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmSeverityCode
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Defines the severity associated to the sfpHighWarningAlarm
 | 
						|
             and enables/disables the trap generation on status change event."
 | 
						|
        DEFVAL {warningTrapEnable}
 | 
						|
    ::= {sfp 12}
 | 
						|
 | 
						|
    sfpLowAlarmSeverityCode  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmSeverityCode
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Defines the severity associated to the sfpLowAlarm
 | 
						|
             and enables/disables the trap generation on status change event."
 | 
						|
        DEFVAL {majorTrapEnable}
 | 
						|
    ::= {sfp 13}
 | 
						|
 | 
						|
    sfpLowWarningAlarmSeverityCode  OBJECT-TYPE
 | 
						|
        SYNTAX      AlarmSeverityCode
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Defines the severity associated to the sfpLowWarningAlarm
 | 
						|
             and enables/disables the trap generation on status change event."
 | 
						|
        DEFVAL {warningTrapEnable}
 | 
						|
    ::= {sfp 14}
 | 
						|
 | 
						|
END
 |