2335 lines
84 KiB
Plaintext
2335 lines
84 KiB
Plaintext
|
|
IEEE8021-BRIDGE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- =============================================================
|
|
-- MIB for IEEE 802.1D devices
|
|
-- =============================================================
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32, Counter64
|
|
FROM SNMPv2-SMI
|
|
RowStatus, MacAddress, TruthValue, TimeInterval
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex, InterfaceIndexOrZero, ifGeneralInformationGroup
|
|
FROM IF-MIB
|
|
ieee802dot1mibs, IEEE8021PbbComponentIdentifier,
|
|
IEEE8021BridgePortNumber, IEEE8021PriorityCodePoint,
|
|
IEEE8021BridgePortType, IEEE8021PriorityValue,
|
|
IEEE8021PbbComponentIdentifierOrZero,
|
|
IEEE8021BridgePortNumberOrZero
|
|
FROM IEEE8021-TC-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
systemGroup
|
|
FROM SNMPv2-MIB
|
|
;
|
|
|
|
ieee8021BridgeMib MODULE-IDENTITY
|
|
LAST-UPDATED "201208100000Z" -- August 10, 2012
|
|
ORGANIZATION "IEEE 802.1 Working Group"
|
|
CONTACT-INFO
|
|
" WG-URL: http://grouper.ieee.org/groups/802/1/index.html
|
|
WG-EMail: stds-802-1@ieee.org
|
|
|
|
Contact: David Levi
|
|
Postal: C/O IEEE 802.1 Working Group
|
|
IEEE Standards Association
|
|
445 Hoes Lane
|
|
P.O. Box 1331
|
|
Piscataway
|
|
NJ 08855-1331
|
|
USA
|
|
E-mail: STDS-802-1-L@LISTSERV.IEEE.ORG"
|
|
DESCRIPTION
|
|
"The Bridge MIB module for managing devices that support
|
|
IEEE 802.1D. This MIB module is derived from the IETF
|
|
BRIDGE-MIB, RFC 4188.
|
|
|
|
Unless otherwise indicated, the references in this MIB
|
|
module are to IEEE Std 802.1Q-2011.
|
|
|
|
Copyright (C) IEEE.
|
|
This version of this MIB module is part of IEEE802.1Q;
|
|
see the draft itself for full legal notices."
|
|
|
|
REVISION "201208100000Z" -- August 10, 2012
|
|
DESCRIPTION "Added an enumeration for tComponent in
|
|
ieee8021BridgeBaseComponentType
|
|
as part of IEEE Std 802.1Q Cor-2."
|
|
|
|
REVISION "201202150000Z" -- February 15, 2012
|
|
DESCRIPTION "Extended ieee8021BridgeBaseComponentType to
|
|
include erComponent and
|
|
ieee8021BridgeBasePortTypeCapabilities to include
|
|
stationFacingBridgePort, uplinkAccessPort and
|
|
uplinkRelayPort.
|
|
Added tables ieee8021BridgeBaseIfToPortTable and
|
|
ieee8021BridgePortTable
|
|
as part of IEEE Std 802.1Qbg."
|
|
|
|
REVISION "201104060000Z" -- April 6, 2011
|
|
DESCRIPTION
|
|
"Modifications to support Remote Customer Service
|
|
Interfaces."
|
|
REVISION "201102270000Z" -- February 27, 2011
|
|
DESCRIPTION
|
|
"Minor edits to contact information etc. as part of
|
|
2011 revision of IEEE Std 802.1Q."
|
|
|
|
REVISION "200810150000Z" -- October 15, 2008
|
|
DESCRIPTION
|
|
"Initial revision, derived from RFC 4188."
|
|
::= { ieee802dot1mibs 2 }
|
|
|
|
-- =============================================================
|
|
-- subtrees in the Bridge MIB
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeNotifications
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeMib 0 }
|
|
|
|
ieee8021BridgeObjects
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeMib 1 }
|
|
|
|
ieee8021BridgeConformance
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeMib 2 }
|
|
|
|
ieee8021BridgeBase
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 1 }
|
|
ieee8021BridgeTp
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 2 }
|
|
ieee8021BridgePriority
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 3 }
|
|
ieee8021BridgeMrp
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 4 }
|
|
ieee8021BridgeMmrp
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 5 }
|
|
ieee8021BridgeInternalLan
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 6 }
|
|
ieee8021BridgeDot1d
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeObjects 7 }
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeBase subtree
|
|
-- =============================================================
|
|
-- Implementation of the ieee8021BridgeBase subtree is mandatory
|
|
-- for all bridges.
|
|
-- =============================================================
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeBaseTable
|
|
-- =============================================================
|
|
ieee8021BridgeBaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeBaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains generic information about every
|
|
bridge component. All writable objects in this table
|
|
MUST be persistent over power up restart/reboot."
|
|
REFERENCE "12.4.1"
|
|
::= { ieee8021BridgeBase 1 }
|
|
|
|
ieee8021BridgeBaseEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeBaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing information for each bridge
|
|
component."
|
|
INDEX { ieee8021BridgeBaseComponentId }
|
|
::= { ieee8021BridgeBaseTable 1 }
|
|
|
|
Ieee8021BridgeBaseEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeBaseComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgeBaseBridgeAddress
|
|
MacAddress,
|
|
ieee8021BridgeBaseNumPorts
|
|
Integer32,
|
|
ieee8021BridgeBaseComponentType
|
|
INTEGER,
|
|
ieee8021BridgeBaseDeviceCapabilities
|
|
BITS,
|
|
ieee8021BridgeBaseTrafficClassesEnabled
|
|
TruthValue,
|
|
ieee8021BridgeBaseMmrpEnabledStatus
|
|
TruthValue,
|
|
ieee8021BridgeBaseRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
ieee8021BridgeBaseComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgeBaseEntry 1 }
|
|
|
|
ieee8021BridgeBaseBridgeAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address used by this bridge when it is
|
|
referred to in a unique fashion. It is recommended
|
|
that this be the numerically smallest MAC address of
|
|
all ports that belong to this bridge. However, it is
|
|
only required to be unique. When concatenated with
|
|
ieee8021SpanningTreePriority, a unique BridgeIdentifier
|
|
is formed, which is used in the Spanning Tree Protocol.
|
|
|
|
This object may not be modified while the corresponding
|
|
instance of ieee8021BridgeBaseRowStatus is active(1).
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "12.4.1.1.3 a)"
|
|
::= { ieee8021BridgeBaseEntry 2 }
|
|
|
|
ieee8021BridgeBaseNumPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ports"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ports controlled by this bridging
|
|
entity."
|
|
REFERENCE "12.4.1.1.3 c)"
|
|
::= { ieee8021BridgeBaseEntry 3 }
|
|
|
|
ieee8021BridgeBaseComponentType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
iComponent(1),
|
|
bComponent(2),
|
|
cVlanComponent(3),
|
|
sVlanComponent(4),
|
|
dBridgeComponent(5),
|
|
erComponent (6),
|
|
tComponent (7)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the component type(s) of this bridge. The
|
|
following component types are possible:
|
|
|
|
iComponent(1) - An S-VLAN component of a Backbone
|
|
Edge Bridge which performs encapsulation of customer
|
|
frames.
|
|
|
|
bComponent(2) - An S-VLAN component of a Backbone
|
|
Edge Bridge which bundles backbone service instances
|
|
into B-VLANs.
|
|
|
|
cVlanComponent(3) - A C-VLAN component of an
|
|
enterprise VLAN bridge or of a Provider Bridge used
|
|
to process C-tagged frames.
|
|
|
|
sVlanComponent(4) - An S-VLAN component of a
|
|
Provider Bridge.
|
|
|
|
dBridgeComponent(5) - A VLAN unaware component of an
|
|
802.1D bridge.
|
|
|
|
erComponent (6) - An Edge Relay component of an EVB Station.
|
|
|
|
tComponent (7) - A TPMR component in a Backbone Edge Bridge.
|
|
|
|
This object may not be modified while the corresponding
|
|
instance of ieee8021BridgeBaseRowStatus is active(1).
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "12.3 m)"
|
|
::= { ieee8021BridgeBaseEntry 4 }
|
|
|
|
ieee8021BridgeBaseDeviceCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
dot1dExtendedFilteringServices(0),
|
|
dot1dTrafficClasses(1),
|
|
dot1qStaticEntryIndividualPort(2),
|
|
dot1qIVLCapable(3),
|
|
dot1qSVLCapable(4),
|
|
dot1qHybridCapable(5),
|
|
dot1qConfigurablePvidTagging(6),
|
|
dot1dLocalVlanCapable(7)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the optional parts of IEEE 802.1D and 802.1Q
|
|
that are implemented by this device and are manageable
|
|
through this MIB. Capabilities that are allowed on a
|
|
per-port basis are indicated in
|
|
ieee8021BridgeBasePortCapabilities.
|
|
|
|
dot1dExtendedFilteringServices(0),
|
|
-- can perform filtering of
|
|
-- individual multicast addresses
|
|
-- controlled by MMRP.
|
|
dot1dTrafficClasses(1),
|
|
-- can map user priority to
|
|
-- multiple traffic classes.
|
|
dot1qStaticEntryIndividualPort(2),
|
|
-- dot1qStaticUnicastReceivePort &
|
|
-- dot1qStaticMulticastReceivePort
|
|
-- can represent non-zero entries.
|
|
dot1qIVLCapable(3), -- Independent VLAN Learning (IVL).
|
|
dot1qSVLCapable(4), -- Shared VLAN Learning (SVL).
|
|
dot1qHybridCapable(5),
|
|
-- both IVL & SVL simultaneously.
|
|
dot1qConfigurablePvidTagging(6),
|
|
-- whether the implementation
|
|
-- supports the ability to
|
|
-- override the default PVID
|
|
-- setting and its egress status
|
|
-- (VLAN-Tagged or Untagged) on
|
|
-- each port.
|
|
dot1dLocalVlanCapable(7)
|
|
-- can support multiple local
|
|
-- bridges, outside of the scope
|
|
-- of 802.1Q defined VLANs.
|
|
|
|
This object may not be modified while the corresponding
|
|
instance of ieee8021BridgeBaseRowStatus is active(1).
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "12.10.1.1.3 b)"
|
|
::= { ieee8021BridgeBaseEntry 5 }
|
|
|
|
ieee8021BridgeBaseTrafficClassesEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value true(1) indicates that Traffic Classes are
|
|
enabled on this bridge. When false(2), the bridge
|
|
operates with a single priority level for all traffic.
|
|
|
|
This object may be modified while the corresponding
|
|
instance of ieee8021BridgeBaseRowStatus is active(1).
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { true }
|
|
::= { ieee8021BridgeBaseEntry 6 }
|
|
|
|
ieee8021BridgeBaseMmrpEnabledStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative status requested by management for
|
|
MMRP. The value true(1) indicates that MMRP should
|
|
be enabled on this device, in all VLANs, on all ports
|
|
for which it has not been specifically disabled. When
|
|
false(2), MMRP is disabled, in all VLANs and on all
|
|
ports, and all MMRP packets will be forwarded
|
|
transparently. This object affects both Applicant and
|
|
Registrar state machines. A transition from false(2)
|
|
to true(1) will cause a reset of all MMRP state
|
|
machines on all ports.
|
|
|
|
This object may be modified while the corresponding
|
|
instance of ieee8021BridgeBaseRowStatus is active(1).
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { true }
|
|
::= { ieee8021BridgeBaseEntry 7 }
|
|
|
|
ieee8021BridgeBaseRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the status of an entry, and is used
|
|
to create/delete entries.
|
|
|
|
The following objects MUST be set prior to making a new
|
|
entry active:
|
|
ieee8021BridgeBaseBridgeAddress
|
|
ieee8021BridgeBaseComponentType
|
|
ieee8021BridgeBaseDeviceCapabilities
|
|
It is recommended that these three objects not be allowed
|
|
to be modified while the corresponding instance of
|
|
ieee8021BridgeBaseRowStatus object is active(1).
|
|
|
|
The following objects are not required to be set before
|
|
making a new entry active (they will take their defaults),
|
|
and they also may be modified while the corresponding
|
|
instance of this object is active(1):
|
|
ieee8021BridgeBaseTrafficClassesEnabled
|
|
ieee8021BridgeBaseMmrpEnabledStatus
|
|
|
|
The value of this object and all corresponding instances
|
|
of other objects in this table MUST be retained across
|
|
reinitializations of the management system."
|
|
::= { ieee8021BridgeBaseEntry 8 }
|
|
|
|
-- =============================================================
|
|
-- The Generic Bridge Port Table
|
|
-- =============================================================
|
|
ieee8021BridgeBasePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeBasePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains generic information about every
|
|
port that is associated with this bridge. Transparent,
|
|
and source-route ports are included."
|
|
REFERENCE "12.4.2"
|
|
::= { ieee8021BridgeBase 4 }
|
|
|
|
ieee8021BridgeBasePortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeBasePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A list of objects containing information for each port
|
|
of the bridge."
|
|
INDEX { ieee8021BridgeBasePortComponentId,
|
|
ieee8021BridgeBasePort }
|
|
::= { ieee8021BridgeBasePortTable 1 }
|
|
|
|
Ieee8021BridgeBasePortEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeBasePortComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgeBasePort
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgeBasePortIfIndex
|
|
InterfaceIndexOrZero,
|
|
ieee8021BridgeBasePortDelayExceededDiscards
|
|
Counter64,
|
|
ieee8021BridgeBasePortMtuExceededDiscards
|
|
Counter64,
|
|
ieee8021BridgeBasePortCapabilities
|
|
BITS,
|
|
ieee8021BridgeBasePortTypeCapabilities
|
|
BITS,
|
|
ieee8021BridgeBasePortType
|
|
IEEE8021BridgePortType,
|
|
ieee8021BridgeBasePortExternal
|
|
TruthValue,
|
|
ieee8021BridgeBasePortAdminPointToPoint
|
|
INTEGER,
|
|
ieee8021BridgeBasePortOperPointToPoint
|
|
TruthValue,
|
|
ieee8021BridgeBasePortName
|
|
SnmpAdminString
|
|
}
|
|
|
|
ieee8021BridgeBasePortComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgeBasePortEntry 1 }
|
|
|
|
ieee8021BridgeBasePort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number of the port for which this entry
|
|
contains bridge management information."
|
|
REFERENCE "12.4.2.1.2 a)"
|
|
::= { ieee8021BridgeBasePortEntry 2 }
|
|
|
|
ieee8021BridgeBasePortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the instance of the IfIndex object,
|
|
defined in the IF-MIB, for the interface corresponding
|
|
to this port, or the value 0 if the port has not been
|
|
bound to an underlying frame source and sink.
|
|
|
|
It is an implementation specific decision as to whether this object
|
|
may be modified if it has been created or if 0 is a legal value.
|
|
|
|
The underlying IfEntry indexed by this column MUST be persistent
|
|
across reinitializations of the management system."
|
|
::= { ieee8021BridgeBasePortEntry 3 }
|
|
|
|
ieee8021BridgeBasePortDelayExceededDiscards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames discarded by this port due
|
|
to excessive transit delay through the bridge. It
|
|
is incremented by both transparent and source
|
|
route bridges.
|
|
|
|
Discontinuities in the value of the counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
ifCounterDiscontinuityTime object of the associated
|
|
interface (if any)."
|
|
REFERENCE "12.6.1.1.3 f)"
|
|
::= { ieee8021BridgeBasePortEntry 4 }
|
|
|
|
ieee8021BridgeBasePortMtuExceededDiscards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames discarded by this port due
|
|
to an excessive size. It is incremented by both
|
|
transparent and source route bridges.
|
|
|
|
Discontinuities in the value of the counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
ifCounterDiscontinuityTime object of the associated
|
|
interface (if any)."
|
|
REFERENCE "12.6.1.1.3 g)"
|
|
::= { ieee8021BridgeBasePortEntry 5 }
|
|
|
|
ieee8021BridgeBasePortCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
dot1qDot1qTagging(0),
|
|
dot1qConfigurableAcceptableFrameTypes(1),
|
|
dot1qIngressFiltering(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the parts of IEEE 802.1D and 802.1Q that are
|
|
optional on a per-port basis, that are implemented by
|
|
this device, and that are manageable through this MIB.
|
|
|
|
dot1qDot1qTagging(0), -- supports 802.1Q VLAN tagging of
|
|
-- frames and MVRP.
|
|
dot1qConfigurableAcceptableFrameTypes(1),
|
|
-- allows modified values of
|
|
-- dot1qPortAcceptableFrameTypes.
|
|
dot1qIngressFiltering(2)
|
|
-- supports the discarding of any
|
|
-- frame received on a Port whose
|
|
-- VLAN classification does not
|
|
-- include that Port in its Member
|
|
-- set."
|
|
REFERENCE "12.10.1.1.3 c)"
|
|
::= { ieee8021BridgeBasePortEntry 6 }
|
|
|
|
ieee8021BridgeBasePortTypeCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
customerVlanPort(0),
|
|
providerNetworkPort(1),
|
|
customerNetworkPort(2),
|
|
customerEdgePort(3),
|
|
customerBackbonePort(4),
|
|
virtualInstancePort(5),
|
|
dBridgePort(6),
|
|
remoteCustomerAccessPort(7),
|
|
stationFacingBridgePort (8),
|
|
uplinkAccessPort (9),
|
|
uplinkRelayPort(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the capabilities of this port. The corresponding
|
|
instance of ieee8021BridgeBasePortType can potentially take
|
|
any of the values for which the corresponding bit in this
|
|
object is 1. The possible port types are as follows:
|
|
|
|
customerVlanPort(0) - Indicates the port can be a C-tag
|
|
aware port of an enterprise VLAN aware bridge.
|
|
|
|
providerNetworkPort(1) - Indicates the port can be an
|
|
S-tag aware port of a Provider Bridge or Backbone
|
|
Edge Bridge used for connections within a PBN or
|
|
PBBN.
|
|
|
|
customerNetworkPort(2) - Indicates the port can be an
|
|
S-tag aware port of a Provider Bridge or Backbone
|
|
Edge Bridge used for connections to the exterior of
|
|
a PBN or PBBN.
|
|
|
|
customerEdgePort(3) - Indicates the port can be a C-tag
|
|
aware port of a Provider Bridge used for connections
|
|
to the exterior of a PBN or PBBN.
|
|
|
|
customerBackbonePort(4) - Indicates the port can be a
|
|
I-tag aware port of a Backbone Edge Bridge's
|
|
B-component.
|
|
|
|
virtualInstancePort(5) - Indicates the port can be a
|
|
virtual S-tag aware port within a Backbone Edge
|
|
Bridge's I-component which is responsible for
|
|
handling S-tagged traffic for a specific backbone
|
|
service instance.
|
|
|
|
dBridgePort(6) - Indicates the port can be a VLAN-unaware
|
|
member of an 802.1D bridge.
|
|
|
|
remoteCustomerAccessPort(7) - Indicates the port can be an
|
|
S-tag aware port of a Provider Bridge capable of providing
|
|
Remote Customer Service Interfaces.
|
|
|
|
stationFacingBridgePort(8) - Indicates the station-facing
|
|
Bridge Port in a EVB Bridge.
|
|
|
|
uplinkAccessPort(9) - Indicates the uplink access port
|
|
in an EVB Bridge or EVB station.
|
|
|
|
uplinkRelayPort (10) - Indicates the uplink relay port
|
|
in an EVB station."
|
|
|
|
REFERENCE "12.16.1.1.3 h4), 12.16.2.1/2,
|
|
12.13.1.1, 12.13.1.2, 12.15.2.1, 12.15.2.2,
|
|
12.26.2, 12.26.4.1, 12.26.5.1"
|
|
::= { ieee8021BridgeBasePortEntry 7 }
|
|
|
|
ieee8021BridgeBasePortType OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port type. This value MUST be persistent over power up
|
|
restart/reboot."
|
|
REFERENCE "12.16.1.1.3 h4), 12.16.2.1/2,
|
|
12.13.1.1, 12.13.1.2, 12.15.2.1, 12.15.2.2,
|
|
12.26.2, 12.26.4.1, 12.26.5.1"
|
|
::= { ieee8021BridgeBasePortEntry 8 }
|
|
|
|
ieee8021BridgeBasePortExternal OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A boolean indicating whether the port is external. A value of
|
|
true(1) means the port is external. A value of false(2) means
|
|
the port is internal."
|
|
REFERENCE "12.16.1.1.3 h4)"
|
|
::= { ieee8021BridgeBasePortEntry 9 }
|
|
|
|
ieee8021BridgeBasePortAdminPointToPoint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
forceTrue(1),
|
|
forceFalse(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For a port running spanning tree, this object represents the
|
|
administrative point-to-point status of the LAN segment
|
|
attached to this port, using the enumeration values of
|
|
6.4.3. A value of forceTrue(1) indicates
|
|
that this port should always be treated as if it is
|
|
connected to a point-to-point link. A value of
|
|
forceFalse(2) indicates that this port should be treated as
|
|
having a shared media connection. A value of auto(3)
|
|
indicates that this port is considered to have a
|
|
point-to-point link if it is an Aggregator and all of its
|
|
members are aggregatable, or if the MAC entity
|
|
is configured for full duplex operation, either through
|
|
auto-negotiation or by management means. Manipulating this
|
|
object changes the underlying adminPointToPointMAC.
|
|
|
|
For a VIP, the adminPointToPointMAC parameter controls
|
|
the mechanism by which the Default Backbone Destination
|
|
parameter for the VIP is determined. For a backbone
|
|
service instance that includes only 2 VIPs, the value
|
|
may be set to forceTrue(1) which permits dynamic learning
|
|
of the Default Backbone Destination parameter. For a
|
|
backbone service instance that includes more than 2 VIPs,
|
|
the value MUST be set to ForceFalse(2) or auto(3).
|
|
|
|
When this object is set to forceTrue(1) for a VIP, the
|
|
Default Backbone Destination parameter is modified by
|
|
the subsequent M_UNITDATA.indications as specified in
|
|
6.10.1 (and described in 26.4.1). Whenever the parameter
|
|
is set to forceFalse(2) or auto(3), the value for the
|
|
Default Backbone Destination parameter is set to the
|
|
Backbone Service Instance Group Address for the VIP-ISID.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "6.6.3, 6.10, 12.8.2.1.3 o), 12.8.2.3.2 f), 26.4.1"
|
|
DEFVAL { forceFalse }
|
|
::= { ieee8021BridgeBasePortEntry 10 }
|
|
|
|
ieee8021BridgeBasePortOperPointToPoint OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For a port running spanning tree, this object represents
|
|
the operational point-to-point status of the LAN segment
|
|
attached to this port. It indicates whether a port is
|
|
considered to have a point-to-point connection.
|
|
If adminPointToPointMAC is set to auto(2), then the value
|
|
of operPointToPointMAC is determined in accordance with the
|
|
specific procedures defined for the MAC entity concerned,
|
|
as defined in 6.7. The value is
|
|
determined dynamically; that is, it is re-evaluated whenever
|
|
the value of adminPointToPointMAC changes, and whenever
|
|
the specific procedures defined for the MAC entity evaluate
|
|
a change in its point-to-point status.
|
|
|
|
For a VIP, this object simply reflects the value of the
|
|
corresponding instance of ieee8021BridgeBasePortAdminPointToPoint.
|
|
The value will be true(1) if that object is forceTrue(1), and
|
|
the value will be false(2) if the value of that object is either
|
|
forceFalse(2) or auto(3)."
|
|
REFERENCE "6.6.3, 6.7, 6.10, 12.8.2.1.3 p), 12.8.2.3.2 f), 26.4.1"
|
|
::= { ieee8021BridgeBasePortEntry 11 }
|
|
|
|
ieee8021BridgeBasePortName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string of up to 32 characters, of locally determined significance."
|
|
REFERENCE "12.4.2.1.3 a)"
|
|
::= { ieee8021BridgeBasePortEntry 12 }
|
|
|
|
-- =============================================================
|
|
-- The Generic Bridge ifIndex to Port Table
|
|
-- =============================================================
|
|
ieee8021BridgeBaseIfToPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeBaseIfToPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains generic information about every
|
|
ifIndex that is associated with this bridge."
|
|
REFERENCE "17.2.2"
|
|
::= { ieee8021BridgeBase 5 }
|
|
|
|
ieee8021BridgeBaseIfToPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeBaseIfToPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A list of objects containing information for each ifIndex
|
|
of the bridge."
|
|
INDEX { ifIndex }
|
|
::= { ieee8021BridgeBaseIfToPortTable 1 }
|
|
|
|
Ieee8021BridgeBaseIfToPortEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeBaseIfIndexComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgeBaseIfIndexPort
|
|
IEEE8021BridgePortNumber
|
|
}
|
|
|
|
ieee8021BridgeBaseIfIndexComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component ID for this ifIndex."
|
|
::= { ieee8021BridgeBaseIfToPortEntry 1 }
|
|
|
|
ieee8021BridgeBaseIfIndexPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port for this ifIndex."
|
|
::= { ieee8021BridgeBaseIfToPortEntry 2 }
|
|
|
|
|
|
-- =============================================================
|
|
-- port number table section 12.5.1
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePhyPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePhyPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains ISS port number to bridge
|
|
componentID and port number mapping."
|
|
REFERENCE "12.5.1"
|
|
::= { ieee8021BridgeBase 6}
|
|
|
|
ieee8021BridgePhyPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePhyPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing mapping for ISS port
|
|
numbers to bridge componentID and port numbers "
|
|
INDEX { ieee8021BridgePhyPort }
|
|
::= { ieee8021BridgePhyPortTable 1 }
|
|
|
|
Ieee8021BridgePhyPortEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgePhyPort
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgePhyPortIfIndex
|
|
InterfaceIndexOrZero,
|
|
ieee8021BridgePhyMacAddress
|
|
MacAddress,
|
|
ieee8021BridgePhyPortToComponentId
|
|
IEEE8021PbbComponentIdentifierOrZero,
|
|
ieee8021BridgePhyPortToInternalPort
|
|
IEEE8021BridgePortNumberOrZero
|
|
}
|
|
|
|
|
|
ieee8021BridgePhyPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ISS port."
|
|
REFERENCE "12.26"
|
|
::= { ieee8021BridgePhyPortEntry 1 }
|
|
|
|
|
|
ieee8021BridgePhyPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the instance of the IfIndex object,
|
|
defined in the IF-MIB, for the interface corresponding
|
|
to this port, or the value 0 if the port has not been
|
|
bound to an underlying frame source and sink.
|
|
|
|
The underlying IfEntry indexed by this column MUST
|
|
be persistent across reinitializations of the
|
|
management system."
|
|
::= { ieee8021BridgePhyPortEntry 2 }
|
|
|
|
ieee8021BridgePhyMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The MAC address"
|
|
::= { ieee8021BridgePhyPortEntry 3 }
|
|
|
|
ieee8021BridgePhyPortToComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifierOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component ID that this ISS port belongs to."
|
|
|
|
::= { ieee8021BridgePhyPortEntry 4 }
|
|
|
|
|
|
ieee8021BridgePhyPortToInternalPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumberOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number to which this ISS port maps to."
|
|
|
|
::= { ieee8021BridgePhyPortEntry 5 }
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeTp subtree
|
|
-- =============================================================
|
|
-- This is implemented by those bridges that support the
|
|
-- transparent bridging mode. A transparent bridge will
|
|
-- implement this subtree.
|
|
-- =============================================================
|
|
|
|
-- =============================================================
|
|
-- Port Table for Transparent Bridges
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeTpPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeTpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about every port that
|
|
is associated with this transparent bridge."
|
|
REFERENCE "12.4.2"
|
|
::= { ieee8021BridgeTp 1 }
|
|
|
|
ieee8021BridgeTpPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeTpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing information for each port of
|
|
a transparent bridge."
|
|
INDEX { ieee8021BridgeTpPortComponentId,
|
|
ieee8021BridgeTpPort }
|
|
::= { ieee8021BridgeTpPortTable 1 }
|
|
|
|
Ieee8021BridgeTpPortEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeTpPortComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgeTpPort
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgeTpPortMaxInfo
|
|
Integer32,
|
|
ieee8021BridgeTpPortInFrames
|
|
Counter64,
|
|
ieee8021BridgeTpPortOutFrames
|
|
Counter64,
|
|
ieee8021BridgeTpPortInDiscards
|
|
Counter64
|
|
}
|
|
|
|
ieee8021BridgeTpPortComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgeTpPortEntry 1 }
|
|
|
|
ieee8021BridgeTpPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number of the port for which this entry
|
|
contains Transparent bridging management information."
|
|
::= { ieee8021BridgeTpPortEntry 2 }
|
|
|
|
ieee8021BridgeTpPortMaxInfo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum size of the INFO (non-MAC) field that
|
|
this port will receive or transmit."
|
|
::= { ieee8021BridgeTpPortEntry 3 }
|
|
|
|
ieee8021BridgeTpPortInFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that have been received by this
|
|
port from its segment. Note that a frame received on the
|
|
interface corresponding to this port is only counted by
|
|
this object if and only if it is for a protocol being
|
|
processed by the local bridging function, including
|
|
bridge management frames.
|
|
|
|
Discontinuities in the value of the counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
ifCounterDiscontinuityTime object of the associated
|
|
interface (if any)."
|
|
REFERENCE "12.6.1.1.3 a)"
|
|
::= { ieee8021BridgeTpPortEntry 4 }
|
|
|
|
ieee8021BridgeTpPortOutFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that have been transmitted by this
|
|
port to its segment. Note that a frame transmitted on
|
|
the interface corresponding to this port is only counted
|
|
by this object if and only if it is for a protocol being
|
|
processed by the local bridging function, including
|
|
bridge management frames.
|
|
|
|
Discontinuities in the value of the counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
ifCounterDiscontinuityTime object of the associated
|
|
interface (if any)."
|
|
REFERENCE "12.6.1.1.3 d)"
|
|
::= { ieee8021BridgeTpPortEntry 5 }
|
|
|
|
ieee8021BridgeTpPortInDiscards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of received valid frames that were discarded
|
|
(i.e., filtered) by the Forwarding Process.
|
|
|
|
Discontinuities in the value of the counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
ifCounterDiscontinuityTime object of the associated
|
|
interface (if any)."
|
|
REFERENCE "12.6.1.1.3 c)"
|
|
::= { ieee8021BridgeTpPortEntry 6 }
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgePriority subtree
|
|
-- =============================================================
|
|
|
|
-- =============================================================
|
|
-- Port Priority Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about every port that
|
|
is associated with this transparent bridge."
|
|
::= { ieee8021BridgePriority 1 }
|
|
|
|
ieee8021BridgePortPriorityEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Default User Priorities for each port of a
|
|
transparent bridge. This is indexed by
|
|
ieee8021BridgeBasePortComponentId and
|
|
ieee8021BridgeBasePort."
|
|
AUGMENTS { ieee8021BridgeBasePortEntry }
|
|
::= { ieee8021BridgePortPriorityTable 1 }
|
|
|
|
Ieee8021BridgePortPriorityEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgePortDefaultUserPriority
|
|
IEEE8021PriorityValue,
|
|
ieee8021BridgePortNumTrafficClasses
|
|
Integer32,
|
|
ieee8021BridgePortPriorityCodePointSelection
|
|
IEEE8021PriorityCodePoint,
|
|
ieee8021BridgePortUseDEI
|
|
TruthValue,
|
|
ieee8021BridgePortRequireDropEncoding
|
|
TruthValue,
|
|
ieee8021BridgePortServiceAccessPrioritySelection
|
|
TruthValue
|
|
}
|
|
|
|
ieee8021BridgePortDefaultUserPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default ingress User Priority for this port. This
|
|
only has effect on media, such as Ethernet, that do not
|
|
support native User Priority.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
::= { ieee8021BridgePortPriorityEntry 1 }
|
|
|
|
ieee8021BridgePortNumTrafficClasses OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of egress traffic classes supported on this
|
|
port. This object may optionally be read-only.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
::= { ieee8021BridgePortPriorityEntry 2 }
|
|
|
|
ieee8021BridgePortPriorityCodePointSelection OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityCodePoint
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object identifies the rows in the PCP encoding and
|
|
decoding tables that are used to remark frames on this
|
|
port if this remarking is enabled."
|
|
REFERENCE "12.6.2.6, 12.6.2.7"
|
|
::= { ieee8021BridgePortPriorityEntry 3 }
|
|
|
|
ieee8021BridgePortUseDEI OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the Use_DEI is set to true(1) for the Port then the
|
|
drop_eligible parameter is encoded in the DEI of transmitted
|
|
frames, and the drop_eligible parameter shall be true(1) for a
|
|
received frame if the DEI is set in the VLAN tag or the Priority
|
|
Code Point Decoding Table indicates drop_eligible True for
|
|
the received PCP value. If the Use_DEI parameter is false(2),
|
|
the DEI shall be transmitted as zero and ignored on receipt.
|
|
The default value of the Use_DEI parameter is false(2)."
|
|
REFERENCE "12.6.2.12, 12.6.2.13"
|
|
::= { ieee8021BridgePortPriorityEntry 4 }
|
|
|
|
ieee8021BridgePortRequireDropEncoding OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If a Bridge supports encoding or decoding of drop_eligible
|
|
from the PCP field of a VLAN tag (6.7.3) on any of its Ports,
|
|
then it shall implement a Boolean parameter Require Drop
|
|
Encoding on each of its Ports with default value false(2). If
|
|
Require Drop Encoding is True and the Bridge Port cannot
|
|
encode particular priorities with drop_eligible, then frames
|
|
queued with those priorities and drop_eligible true(1) shall
|
|
be discarded and not transmitted."
|
|
REFERENCE "12.6.2.14, 12.6.2.15"
|
|
DEFVAL { false }
|
|
::= { ieee8021BridgePortPriorityEntry 5 }
|
|
|
|
ieee8021BridgePortServiceAccessPrioritySelection OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of whether the Service Access Priority Selection
|
|
function is supported on the Customer Bridge Port to request
|
|
priority handling of the frame from a Port-based service
|
|
interface."
|
|
REFERENCE "12.6.2.16, 12.6.2.17"
|
|
::= { ieee8021BridgePortPriorityEntry 6 }
|
|
|
|
-- =============================================================
|
|
-- User Priority Regeneration Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeUserPriorityRegenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeUserPriorityRegenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Regenerated User Priorities for each received
|
|
User Priority on each port of a bridge. The Regenerated
|
|
User Priority value may be used to index the Traffic
|
|
Class Table for each input port. This only has effect
|
|
on media that support native User Priority. The default
|
|
values for Regenerated User Priorities are the same as
|
|
the User Priorities."
|
|
REFERENCE "6.5"
|
|
::= { ieee8021BridgePriority 2 }
|
|
|
|
ieee8021BridgeUserPriorityRegenEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeUserPriorityRegenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mapping of incoming User Priority to a Regenerated
|
|
User Priority."
|
|
INDEX { ieee8021BridgeBasePortComponentId,
|
|
ieee8021BridgeBasePort,
|
|
ieee8021BridgeUserPriority }
|
|
::= { ieee8021BridgeUserPriorityRegenTable 1 }
|
|
|
|
Ieee8021BridgeUserPriorityRegenEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeUserPriority
|
|
IEEE8021PriorityValue,
|
|
ieee8021BridgeRegenUserPriority
|
|
IEEE8021PriorityValue
|
|
}
|
|
|
|
ieee8021BridgeUserPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The User Priority for a frame received on this port."
|
|
::= { ieee8021BridgeUserPriorityRegenEntry 1 }
|
|
|
|
ieee8021BridgeRegenUserPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regenerated User Priority that the incoming User
|
|
Priority is mapped to for this port.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
::= { ieee8021BridgeUserPriorityRegenEntry 2 }
|
|
|
|
-- =============================================================
|
|
-- Traffic Class Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeTrafficClassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeTrafficClassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table mapping evaluated User Priority to Traffic
|
|
Class, for forwarding by the bridge. Traffic class is a
|
|
number in the range (0..(ieee8021BridgePortNumTrafficClasses-1))."
|
|
REFERENCE "Table 8-4"
|
|
::= { ieee8021BridgePriority 3 }
|
|
|
|
ieee8021BridgeTrafficClassEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeTrafficClassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User Priority to Traffic Class mapping."
|
|
INDEX { ieee8021BridgeBasePortComponentId,
|
|
ieee8021BridgeBasePort,
|
|
ieee8021BridgeTrafficClassPriority }
|
|
::= { ieee8021BridgeTrafficClassTable 1 }
|
|
|
|
Ieee8021BridgeTrafficClassEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeTrafficClassPriority
|
|
IEEE8021PriorityValue,
|
|
ieee8021BridgeTrafficClass
|
|
Integer32
|
|
}
|
|
|
|
ieee8021BridgeTrafficClassPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Priority value determined for the received frame.
|
|
This value is equivalent to the priority indicated in
|
|
the tagged frame received, or one of the evaluated
|
|
priorities, determined according to the media-type.
|
|
For untagged frames received from Ethernet media, this
|
|
value is equal to the ieee8021BridgePortDefaultUserPriority value
|
|
for the ingress port.
|
|
|
|
For untagged frames received from non-Ethernet media,
|
|
this value is equal to the ieee8021BridgeRegenUserPriority value
|
|
for the ingress port and media-specific user priority."
|
|
::= { ieee8021BridgeTrafficClassEntry 1 }
|
|
|
|
ieee8021BridgeTrafficClass OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Traffic Class the received frame is mapped to.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
::= { ieee8021BridgeTrafficClassEntry 2 }
|
|
|
|
-- =============================================================
|
|
-- Outbound Access Priority Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortOutboundAccessPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortOutboundAccessPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table mapping Regenerated User Priority to Outbound
|
|
Access Priority. This is a fixed mapping for all port
|
|
types, with three options for 802.17 RPR."
|
|
REFERENCE "6.6.1 and 6.7.3"
|
|
::= { ieee8021BridgePriority 4 }
|
|
|
|
ieee8021BridgePortOutboundAccessPriorityEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortOutboundAccessPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regenerated User Priority to Outbound Access Priority
|
|
mapping."
|
|
INDEX { ieee8021BridgeBasePortComponentId,
|
|
ieee8021BridgeBasePort,
|
|
ieee8021BridgeRegenUserPriority }
|
|
::= { ieee8021BridgePortOutboundAccessPriorityTable 1 }
|
|
|
|
Ieee8021BridgePortOutboundAccessPriorityEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgePortOutboundAccessPriority
|
|
IEEE8021PriorityValue
|
|
}
|
|
|
|
ieee8021BridgePortOutboundAccessPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Outbound Access Priority the received frame is
|
|
mapped to."
|
|
::= { ieee8021BridgePortOutboundAccessPriorityEntry 1 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021BridgePortDecodingTable:
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortDecodingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortDecodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about Priority Code
|
|
Point Decoding Table for a Port of a provider bridge.
|
|
Alternative values for each table are specified as rows
|
|
in Table 6-4 (6.7.3), with each alternative labeled by
|
|
the number of distinct priorities that can be communicated,
|
|
and the number of these for which drop precedence can
|
|
be communicated. All writable objects in this table MUST
|
|
be persistent over power up restart/reboot."
|
|
::= { ieee8021BridgePriority 5 }
|
|
|
|
ieee8021BridgePortDecodingEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortDecodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing Priority Code Point Decoding
|
|
information for a port of a provider bridge."
|
|
INDEX { ieee8021BridgePortDecodingComponentId,
|
|
ieee8021BridgePortDecodingPortNum,
|
|
ieee8021BridgePortDecodingPriorityCodePointRow,
|
|
ieee8021BridgePortDecodingPriorityCodePoint }
|
|
::= { ieee8021BridgePortDecodingTable 1 }
|
|
|
|
Ieee8021BridgePortDecodingEntry ::= SEQUENCE {
|
|
ieee8021BridgePortDecodingComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgePortDecodingPortNum
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgePortDecodingPriorityCodePointRow
|
|
IEEE8021PriorityCodePoint,
|
|
ieee8021BridgePortDecodingPriorityCodePoint
|
|
Integer32,
|
|
ieee8021BridgePortDecodingPriority
|
|
IEEE8021PriorityValue,
|
|
ieee8021BridgePortDecodingDropEligible
|
|
TruthValue
|
|
}
|
|
|
|
ieee8021BridgePortDecodingComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgePortDecodingEntry 1 }
|
|
|
|
ieee8021BridgePortDecodingPortNum OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of a port controlled by this VLAN
|
|
bridging entity."
|
|
::= { ieee8021BridgePortDecodingEntry 2 }
|
|
|
|
ieee8021BridgePortDecodingPriorityCodePointRow OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityCodePoint
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific row in Table 6-3 (6.7.3) indicating the PCP."
|
|
::= { ieee8021BridgePortDecodingEntry 3 }
|
|
|
|
ieee8021BridgePortDecodingPriorityCodePoint OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific PCP value in Table 6-3 (6.7.3)."
|
|
::= { ieee8021BridgePortDecodingEntry 4 }
|
|
|
|
ieee8021BridgePortDecodingPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific priority value in Table 6-3 (6.7.3)."
|
|
REFERENCE "12.6.2.8, 12.6.2.9"
|
|
::= { ieee8021BridgePortDecodingEntry 5 }
|
|
|
|
ieee8021BridgePortDecodingDropEligible OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The drop eligibility value in Table 6-3 (6.7.3)."
|
|
REFERENCE "12.6.2.8, 12.6.2.9"
|
|
::= { ieee8021BridgePortDecodingEntry 6 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021BridgePortEncodingTable:
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortEncodingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortEncodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about Priority Code
|
|
Point Decoding Table for a Port of a provider bridge.
|
|
Alternative values for each table are specified as rows
|
|
in Table 6-3 (6.7.3), with each alternative labeled by
|
|
the number of distinct priorities that can be communicated,
|
|
and the number of these for which drop precedence can be
|
|
communicated. All writable objects in this table MUST be
|
|
persistent over power up restart/reboot."
|
|
::= { ieee8021BridgePriority 6 }
|
|
|
|
ieee8021BridgePortEncodingEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortEncodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing Priority Code Point Encoding
|
|
information for a port of a provider bridge."
|
|
INDEX { ieee8021BridgePortEncodingComponentId,
|
|
ieee8021BridgePortEncodingPortNum,
|
|
ieee8021BridgePortEncodingPriorityCodePointRow,
|
|
ieee8021BridgePortEncodingPriorityCodePoint,
|
|
ieee8021BridgePortEncodingDropEligible }
|
|
::= { ieee8021BridgePortEncodingTable 1 }
|
|
|
|
Ieee8021BridgePortEncodingEntry ::= SEQUENCE {
|
|
ieee8021BridgePortEncodingComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgePortEncodingPortNum
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgePortEncodingPriorityCodePointRow
|
|
IEEE8021PriorityCodePoint,
|
|
ieee8021BridgePortEncodingPriorityCodePoint
|
|
Integer32,
|
|
ieee8021BridgePortEncodingDropEligible
|
|
TruthValue,
|
|
ieee8021BridgePortEncodingPriority
|
|
IEEE8021PriorityValue
|
|
}
|
|
|
|
ieee8021BridgePortEncodingComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgePortEncodingEntry 1 }
|
|
|
|
ieee8021BridgePortEncodingPortNum OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of a port controlled by this VLAN bridging
|
|
entity."
|
|
::= { ieee8021BridgePortEncodingEntry 2 }
|
|
|
|
ieee8021BridgePortEncodingPriorityCodePointRow OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityCodePoint
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific row in Table 6-3 (6.7.3)indicating the PCP row.
|
|
(i.e. 8P0D, 7P1D, 6P2D, 5P3D)"
|
|
::= { ieee8021BridgePortEncodingEntry 3 }
|
|
|
|
ieee8021BridgePortEncodingPriorityCodePoint OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific row in Table 6-3 (6.7.3) indicating the PCP.
|
|
(i.e., 0,1,2,3,4,5,6,7)."
|
|
::= { ieee8021BridgePortEncodingEntry 4 }
|
|
|
|
ieee8021BridgePortEncodingDropEligible OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific row in Table 6-3 (6.7.3) indicating the drop
|
|
eligibility. A value of true(1) means eligible for drop."
|
|
::= { ieee8021BridgePortEncodingEntry 5 }
|
|
|
|
ieee8021BridgePortEncodingPriority OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encoding priority in Table 6-3 (6.7.3)."
|
|
REFERENCE "12.6.2.10, 12.6.2.11"
|
|
::= { ieee8021BridgePortEncodingEntry 6 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021BridgeServiceAccessPriorityTable:
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeServiceAccessPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeServiceAccessPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about the Service Access
|
|
Priority Selection function for a provider bridge. The use
|
|
of this table enables a mechanism for a Customer Bridge
|
|
attached to a Provider Bridged Network to request priority
|
|
handling of frames. All writable objects in this table MUST
|
|
be persistent over power up restart/reboot."
|
|
::= { ieee8021BridgePriority 7 }
|
|
|
|
ieee8021BridgeServiceAccessPriorityEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeServiceAccessPriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of objects containing information about the Service
|
|
Access Priority Selection function for a provider bridge."
|
|
INDEX { ieee8021BridgeServiceAccessPriorityComponentId,
|
|
ieee8021BridgeServiceAccessPriorityPortNum,
|
|
ieee8021BridgeServiceAccessPriorityReceived }
|
|
::= { ieee8021BridgeServiceAccessPriorityTable 1 }
|
|
|
|
Ieee8021BridgeServiceAccessPriorityEntry ::= SEQUENCE {
|
|
ieee8021BridgeServiceAccessPriorityComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgeServiceAccessPriorityPortNum
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgeServiceAccessPriorityReceived
|
|
IEEE8021PriorityValue,
|
|
ieee8021BridgeServiceAccessPriorityValue
|
|
IEEE8021PriorityValue
|
|
}
|
|
|
|
ieee8021BridgeServiceAccessPriorityComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgeServiceAccessPriorityEntry 1 }
|
|
|
|
ieee8021BridgeServiceAccessPriorityPortNum OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of a port controlled by this VLAN bridging
|
|
entity."
|
|
::= { ieee8021BridgeServiceAccessPriorityEntry 2 }
|
|
|
|
ieee8021BridgeServiceAccessPriorityReceived OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default received priority value in Table 6-3 (6.7.3).
|
|
(i.e., 0,1,2,3,4,5,6,7)"
|
|
::= { ieee8021BridgeServiceAccessPriorityEntry 3 }
|
|
|
|
ieee8021BridgeServiceAccessPriorityValue OBJECT-TYPE
|
|
SYNTAX IEEE8021PriorityValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The regenerated priority value in Table 6-3 (6.7.3).
|
|
(i.e., 0,1,2,3,4,5,6,7)"
|
|
REFERENCE "12.6.2.18, 12.6.2.19"
|
|
::= { ieee8021BridgeServiceAccessPriorityEntry 4 }
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeMrp subtree
|
|
-- =============================================================
|
|
|
|
-- =============================================================
|
|
-- The MRP Port Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortMrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortMrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of MRP control information about every bridge
|
|
port. This is indexed by ieee8021BridgeBasePortComponentId
|
|
and ieee8021BridgeBasePort."
|
|
::= { ieee8021BridgeMrp 1 }
|
|
|
|
ieee8021BridgePortMrpEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortMrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MRP control information for a bridge port."
|
|
AUGMENTS { ieee8021BridgeBasePortEntry }
|
|
::= { ieee8021BridgePortMrpTable 1 }
|
|
|
|
Ieee8021BridgePortMrpEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgePortMrpJoinTime
|
|
TimeInterval,
|
|
ieee8021BridgePortMrpLeaveTime
|
|
TimeInterval,
|
|
ieee8021BridgePortMrpLeaveAllTime
|
|
TimeInterval
|
|
}
|
|
|
|
ieee8021BridgePortMrpJoinTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MRP Join time, in centiseconds.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { 20 }
|
|
::= { ieee8021BridgePortMrpEntry 1 }
|
|
|
|
ieee8021BridgePortMrpLeaveTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MRP Leave time, in centiseconds.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { 60 }
|
|
::= { ieee8021BridgePortMrpEntry 2 }
|
|
|
|
ieee8021BridgePortMrpLeaveAllTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MRP LeaveAll time, in centiseconds.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { 1000 }
|
|
::= { ieee8021BridgePortMrpEntry 3 }
|
|
|
|
-- =============================================================
|
|
-- The MMRP Port Configuration and Status Table
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePortMmrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePortMmrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of MMRP control and status information about
|
|
every bridge port. Augments the ieee8021BridgeBasePortTable."
|
|
::= { ieee8021BridgeMmrp 1 }
|
|
|
|
ieee8021BridgePortMmrpEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePortMmrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MMRP control and status information for a bridge port."
|
|
AUGMENTS { ieee8021BridgeBasePortEntry }
|
|
::= { ieee8021BridgePortMmrpTable 1 }
|
|
|
|
Ieee8021BridgePortMmrpEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgePortMmrpEnabledStatus
|
|
TruthValue,
|
|
ieee8021BridgePortMmrpFailedRegistrations
|
|
Counter64,
|
|
ieee8021BridgePortMmrpLastPduOrigin
|
|
MacAddress,
|
|
ieee8021BridgePortRestrictedGroupRegistration
|
|
TruthValue
|
|
}
|
|
|
|
ieee8021BridgePortMmrpEnabledStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative state of MMRP operation on this port. The
|
|
value true(1) indicates that MMRP is enabled on this port
|
|
in all VLANs as long as ieee8021BridgeMmrpEnabledStatus is
|
|
also true(1). A value of false(2) indicates that MMRP is
|
|
disabled on this port in all VLANs: any MMRP packets received
|
|
will be silently discarded, and no MMRP registrations will be
|
|
propagated from other ports. Setting this to a value of
|
|
true(1) will be stored by the agent but will only take
|
|
effect on the MMRP protocol operation if
|
|
ieee8021BridgeMmrpEnabledStatus
|
|
also indicates the value true(1). This object affects
|
|
all MMRP Applicant and Registrar state machines on this
|
|
port. A transition from false(2) to true(1) will
|
|
cause a reset of all MMRP state machines on this port.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
DEFVAL { true }
|
|
::= { ieee8021BridgePortMmrpEntry 1 }
|
|
|
|
ieee8021BridgePortMmrpFailedRegistrations OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "failed MMRP registrations"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of failed MMRP registrations, for any
|
|
reason, in all VLANs, on this port."
|
|
::= { ieee8021BridgePortMmrpEntry 2 }
|
|
|
|
ieee8021BridgePortMmrpLastPduOrigin OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source MAC Address of the last MMRP message
|
|
received on this port."
|
|
::= { ieee8021BridgePortMmrpEntry 3 }
|
|
|
|
ieee8021BridgePortRestrictedGroupRegistration OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of Restricted Group Registration on this port.
|
|
If the value of this control is true(1), then creation
|
|
of a new dynamic entry is permitted only if there is a
|
|
Static Filtering Entry for the VLAN concerned, in which
|
|
the Registrar Administrative Control value is Normal
|
|
Registration.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "11.2.3.2.3, 12.11.1.3"
|
|
DEFVAL { false }
|
|
::= { ieee8021BridgePortMmrpEntry 4 }
|
|
|
|
-- ===========================================================
|
|
-- I-LAN Interface configuration table
|
|
-- ===========================================================
|
|
|
|
ieee8021BridgeILanIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeILanIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is a sparse augmentation of ifTable and controls
|
|
the creation of the I-LAN Interface. An I-LAN Interface is
|
|
used to create internal connections between bridge ports in a
|
|
802.1 device. An I-LAN Interfaces can be directly associated
|
|
with a set of bridge ports. An I-LAN Interfaces can also be
|
|
used as a stacking interface to relate other interfaces before
|
|
association to bridge ports.
|
|
|
|
For example, an I-LAN interface can be created to link traffic
|
|
between a PIP and a CBP. In this case a CBP is created on the
|
|
B-Component and the CBP's related IfEntry is stacked upon the
|
|
IfEntry of the I-LAN. The PIP is stacked upon the I-LAN using
|
|
the IfStackTable. Finally, a VIP is created on the I-Component
|
|
and is associated with the PIP, thus completing the path from
|
|
the I-Component's MAC relay to the CBP on the B-Component.
|
|
|
|
Entries in this table MUST be persistent over power up
|
|
restart/reboot."
|
|
REFERENCE "17.3.2.2"
|
|
::= { ieee8021BridgeInternalLan 1 }
|
|
|
|
ieee8021BridgeILanIfEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeILanIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry consists of a Row Status to control creation."
|
|
INDEX { ifIndex }
|
|
::= { ieee8021BridgeILanIfTable 1 }
|
|
|
|
Ieee8021BridgeILanIfEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeILanIfRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
ieee8021BridgeILanIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and delete entries in this
|
|
table and the Interface table."
|
|
::= { ieee8021BridgeILanIfEntry 1 }
|
|
|
|
-- ===========================================================
|
|
-- 802.1D Dynamic Port Creation table
|
|
-- ===========================================================
|
|
|
|
ieee8021BridgeDot1dPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgeDot1dPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides the capability to dynamically create and
|
|
delete 802.1D bridge ports. Each entry in this table MUST
|
|
have a corresponding entry in the ieee8021BridgeBasePortTable.
|
|
|
|
Entries in this table MUST be persistent over power up
|
|
restart/reboot."
|
|
REFERENCE "17.5.3"
|
|
::= { ieee8021BridgeDot1d 1 }
|
|
|
|
ieee8021BridgeDot1dPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgeDot1dPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry consists of a Row Status to control creation."
|
|
INDEX { ieee8021BridgeBasePortComponentId,
|
|
ieee8021BridgeBasePort }
|
|
::= { ieee8021BridgeDot1dPortTable 1 }
|
|
|
|
Ieee8021BridgeDot1dPortEntry ::=
|
|
SEQUENCE {
|
|
ieee8021BridgeDot1dPortRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
ieee8021BridgeDot1dPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and delete entries in this
|
|
table and the ieee8021BridgeBasePortTable."
|
|
::= { ieee8021BridgeDot1dPortEntry 1 }
|
|
|
|
|
|
-- =============================================================
|
|
-- IEEE 802.1D MIB - Conformance Information
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeCompliances
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeConformance 1 }
|
|
ieee8021BridgeGroups
|
|
OBJECT IDENTIFIER ::= { ieee8021BridgeConformance 2 }
|
|
|
|
-- =============================================================
|
|
-- units of conformance
|
|
-- =============================================================
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeBase group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeBaseBridgeGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseBridgeAddress,
|
|
ieee8021BridgeBaseNumPorts,
|
|
ieee8021BridgeBaseComponentType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridge level information for this device."
|
|
::= { ieee8021BridgeGroups 1 }
|
|
|
|
ieee8021BridgeBasePortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBasePortIfIndex,
|
|
ieee8021BridgeBasePortDelayExceededDiscards,
|
|
ieee8021BridgeBasePortMtuExceededDiscards,
|
|
ieee8021BridgeBasePortType,
|
|
ieee8021BridgeBasePortExternal,
|
|
ieee8021BridgeBasePortAdminPointToPoint,
|
|
ieee8021BridgeBasePortOperPointToPoint,
|
|
ieee8021BridgeBasePortName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information for each port on this device."
|
|
::= { ieee8021BridgeGroups 2 }
|
|
|
|
ieee8021BridgeCapGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseDeviceCapabilities,
|
|
ieee8021BridgeBasePortCapabilities,
|
|
ieee8021BridgeBasePortTypeCapabilities
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects indicating the optional
|
|
capabilities of the device."
|
|
::= { ieee8021BridgeGroups 3 }
|
|
|
|
ieee8021BridgeDeviceMmrpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseMmrpEnabledStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing device-level control
|
|
for the Multicast Filtering extended bridge services."
|
|
::= { ieee8021BridgeGroups 4 }
|
|
|
|
-- =============================================================
|
|
-- the ieee8021BridgeTp group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeTpPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeTpPortMaxInfo,
|
|
ieee8021BridgeTpPortInFrames,
|
|
ieee8021BridgeTpPortOutFrames,
|
|
ieee8021BridgeTpPortInDiscards
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dynamic Filtering Database information for each port of
|
|
the Bridge."
|
|
::= { ieee8021BridgeGroups 6 }
|
|
|
|
-- =============================================================
|
|
-- Bridge Priority groups
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeDevicePriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseTrafficClassesEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing device-level control
|
|
for the Priority services."
|
|
::= { ieee8021BridgeGroups 7 }
|
|
|
|
ieee8021BridgeDefaultPriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortDefaultUserPriority,
|
|
ieee8021BridgePortPriorityCodePointSelection,
|
|
ieee8021BridgePortUseDEI,
|
|
ieee8021BridgePortRequireDropEncoding,
|
|
ieee8021BridgePortServiceAccessPrioritySelection
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects defining the User Priority
|
|
applicable to each port for media that do not support
|
|
native User Priority."
|
|
::= { ieee8021BridgeGroups 8 }
|
|
|
|
ieee8021BridgeRegenPriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeRegenUserPriority
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects defining the User Priorities
|
|
applicable to each port for media that support native
|
|
User Priority."
|
|
::= { ieee8021BridgeGroups 9 }
|
|
|
|
ieee8021BridgePriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortNumTrafficClasses,
|
|
ieee8021BridgeTrafficClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects defining the traffic classes
|
|
within a bridge for each evaluated User Priority."
|
|
::= { ieee8021BridgeGroups 10 }
|
|
|
|
ieee8021BridgeAccessPriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortOutboundAccessPriority
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects defining the media-dependent
|
|
outbound access level for each priority."
|
|
::= { ieee8021BridgeGroups 11 }
|
|
|
|
ieee8021BridgePortMrpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortMrpJoinTime,
|
|
ieee8021BridgePortMrpLeaveTime,
|
|
ieee8021BridgePortMrpLeaveAllTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing port level control
|
|
and status information for MRP operation."
|
|
::= { ieee8021BridgeGroups 12 }
|
|
|
|
ieee8021BridgePortMmrpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortMmrpEnabledStatus,
|
|
ieee8021BridgePortMmrpFailedRegistrations,
|
|
ieee8021BridgePortMmrpLastPduOrigin,
|
|
ieee8021BridgePortRestrictedGroupRegistration
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing port level control
|
|
and status information for MMRP operation."
|
|
::= { ieee8021BridgeGroups 13 }
|
|
|
|
ieee8021BridgePortDecodingGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortDecodingPriority,
|
|
ieee8021BridgePortDecodingDropEligible
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics counters for
|
|
decoding priority and drop eligibility for bridge ports."
|
|
::= { ieee8021BridgeGroups 14 }
|
|
|
|
ieee8021BridgePortEncodingGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePortEncodingPriority
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics counters for
|
|
encoding priority and drop eligibility for bridge ports."
|
|
::= { ieee8021BridgeGroups 15 }
|
|
|
|
ieee8021BridgeServiceAccessPriorityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeServiceAccessPriorityValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics
|
|
counters for service access priority."
|
|
::= { ieee8021BridgeGroups 16 }
|
|
|
|
-- =============================================================
|
|
-- Internal LAN group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeInternalLANGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeILanIfRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing control of internal
|
|
LAN configuration."
|
|
::= { ieee8021BridgeGroups 17 }
|
|
|
|
-- =============================================================
|
|
-- Bridge Creation Group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeCreatableBaseBridgeGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the managment system directed creation of
|
|
Bridge Components."
|
|
::= { ieee8021BridgeGroups 18 }
|
|
|
|
-- =============================================================
|
|
-- Dot1d Dynamic Port Creation group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeDot1dDynamicPortCreationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeDot1dPortRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing dynamic creation and
|
|
deletion of 802.1D bridge ports."
|
|
::= { ieee8021BridgeGroups 19 }
|
|
|
|
|
|
-- =============================================================
|
|
-- Bridge interface index to port table group
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeBaseIfToPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgeBaseIfIndexComponentId,
|
|
ieee8021BridgeBaseIfIndexPort
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing a map between interface
|
|
index and component ID and bridge ports."
|
|
::= { ieee8021BridgeGroups 20 }
|
|
|
|
|
|
|
|
-- =============================================================
|
|
-- Bridge interface index to component group
|
|
-- =============================================================
|
|
ieee8021BridgePhyPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePhyPortIfIndex,
|
|
ieee8021BridgePhyMacAddress,
|
|
ieee8021BridgePhyPortToComponentId,
|
|
ieee8021BridgePhyPortToInternalPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to represent a ISS port management objects."
|
|
::= { ieee8021BridgeGroups 21 }
|
|
|
|
|
|
-- =============================================================
|
|
-- compliance statements
|
|
-- =============================================================
|
|
|
|
ieee8021BridgeCompliance1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices supporting bridging
|
|
services as defined in 802.1D-2004. Such devices support
|
|
path cost values of 32-bits, and bridge and port priority
|
|
values are more restricted than in 802.1D-1995.
|
|
|
|
Full support for the 802.1D management objects requires
|
|
implementation of the objects listed in the systemGroup
|
|
from the SNMPv2-MIB [RFC3418], as well as the objects
|
|
listed in the ifGeneralInformationGroup from the
|
|
IF-MIB [RFC2863]."
|
|
|
|
MODULE SNMPv2-MIB -- The SNMPv2-MIB, RFC 3418
|
|
MANDATORY-GROUPS {
|
|
systemGroup
|
|
}
|
|
|
|
MODULE IF-MIB -- The interfaces MIB, RFC 2863
|
|
MANDATORY-GROUPS {
|
|
ifGeneralInformationGroup
|
|
}
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ieee8021BridgeBaseBridgeGroup,
|
|
ieee8021BridgeBasePortGroup
|
|
}
|
|
|
|
GROUP ieee8021BridgeCreatableBaseBridgeGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is mandatory for
|
|
bridges that allow management systems to add and delete
|
|
bridge components. Provider Backbone Edge Bridges would
|
|
typically fall in this category."
|
|
|
|
GROUP ieee8021BridgeTpPortGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is mandatory for
|
|
bridges that support the transparent bridging
|
|
mode. A transparent bridge will implement
|
|
this group."
|
|
|
|
GROUP ieee8021BridgeInternalLANGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional. It can be supported
|
|
to provide control over the relationship between interfaces and
|
|
bridge ports where such relationships are more complex than a
|
|
simple 1-to-1 mapping."
|
|
|
|
GROUP ieee8021BridgeDot1dDynamicPortCreationGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional. It can be supported
|
|
to provide the ability to dynamically create and deleted 802.1D
|
|
bridge ports."
|
|
|
|
GROUP ieee8021BridgeBaseIfToPortGroup
|
|
DESCRIPTION
|
|
"A collection of objects providing a map between interface
|
|
index and component ID and bridge ports."
|
|
GROUP ieee8021BridgePhyPortGroup
|
|
DESCRIPTION
|
|
"A colelction of objects providing a map between port numbers
|
|
to the component id, interface index."
|
|
|
|
::= { ieee8021BridgeCompliances 3 }
|
|
|
|
|
|
ieee8021BridgeCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices supporting bridging
|
|
services as defined in 802.1D-2004. Such devices support
|
|
path cost values of 32-bits, and bridge and port priority
|
|
values are more restricted than in 802.1D-1995.
|
|
|
|
Full support for the 802.1D management objects requires
|
|
implementation of the objects listed in the systemGroup
|
|
from the SNMPv2-MIB [RFC3418], as well as the objects
|
|
listed in the ifGeneralInformationGroup from the
|
|
IF-MIB [RFC2863]."
|
|
|
|
MODULE SNMPv2-MIB -- The SNMPv2-MIB, RFC 3418
|
|
MANDATORY-GROUPS {
|
|
systemGroup
|
|
}
|
|
|
|
MODULE IF-MIB -- The interfaces MIB, RFC 2863
|
|
MANDATORY-GROUPS {
|
|
ifGeneralInformationGroup
|
|
}
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ieee8021BridgeBaseBridgeGroup,
|
|
ieee8021BridgeBasePortGroup
|
|
}
|
|
|
|
GROUP ieee8021BridgeCreatableBaseBridgeGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is mandatory for
|
|
bridges that allow management systems to add and delete
|
|
bridge components. Provider Backbone Edge Bridges would
|
|
typically fall in this category."
|
|
|
|
GROUP ieee8021BridgeTpPortGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is mandatory for
|
|
bridges that support the transparent bridging
|
|
mode. A transparent bridge will implement
|
|
this group."
|
|
|
|
GROUP ieee8021BridgeInternalLANGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional. It can be supported
|
|
to provide control over the relationship between interfaces and
|
|
bridge ports where such relationships are more complex than a
|
|
simple 1-to-1 mapping."
|
|
|
|
GROUP ieee8021BridgeDot1dDynamicPortCreationGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional. It can be supported
|
|
to provide the ability to dynamically create and deleted 802.1D
|
|
bridge ports."
|
|
|
|
::= { ieee8021BridgeCompliances 1 }
|
|
|
|
ieee8021BridgePriorityAndMulticastFilteringCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for device support of Priority
|
|
and Multicast Filtering extended bridging services."
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS { ieee8021BridgeCapGroup }
|
|
|
|
GROUP ieee8021BridgeDeviceMmrpGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for devices supporting the MMRP
|
|
application, defined by IEEE 802.1D Extended Filtering
|
|
Services."
|
|
|
|
GROUP ieee8021BridgeDevicePriorityGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for devices supporting
|
|
the priority forwarding operations defined by IEEE
|
|
802.1D."
|
|
|
|
GROUP ieee8021BridgeDefaultPriorityGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for devices supporting
|
|
the priority forwarding operations defined by the
|
|
extended bridge services with media types, such as
|
|
Ethernet, that do not support native User Priority."
|
|
|
|
GROUP ieee8021BridgeRegenPriorityGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for devices supporting
|
|
the priority forwarding operations defined by IEEE 802.1D
|
|
and that have interface media types that support
|
|
native User Priority, e.g., IEEE 802.17."
|
|
|
|
GROUP ieee8021BridgePriorityGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for devices supporting
|
|
the priority forwarding operations defined by IEEE 802.1D."
|
|
|
|
GROUP ieee8021BridgeAccessPriorityGroup
|
|
DESCRIPTION
|
|
"This group is optional and is relevant only for devices
|
|
supporting the priority forwarding operations defined by
|
|
IEEE 802.1D and that have interface media types that
|
|
support native Access Priority, e.g., IEEE 802.17."
|
|
|
|
GROUP ieee8021BridgePortMrpGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for devices supporting any
|
|
of the MRP applications: e.g., MMRP, defined by the
|
|
extended filtering services of 802.1D; or MVRP,
|
|
defined by 802.1Q (refer to the Q-BRIDGE-MIB for
|
|
conformance statements for MVRP)."
|
|
|
|
GROUP ieee8021BridgePortMmrpGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for devices supporting the
|
|
MMRP application, as defined by IEEE 802.1D Extended
|
|
Filtering Services."
|
|
|
|
GROUP ieee8021BridgePortDecodingGroup
|
|
DESCRIPTION
|
|
"This group is optional and supports Priority Code Point
|
|
Decoding Table for a Port of a provider bridge."
|
|
|
|
GROUP ieee8021BridgePortEncodingGroup
|
|
DESCRIPTION
|
|
"This group is optional and supports Priority Code Point
|
|
Encoding Table for a Port of a provider bridge."
|
|
|
|
GROUP ieee8021BridgeServiceAccessPriorityGroup
|
|
DESCRIPTION
|
|
"This group is optional and supports Priority Code Point
|
|
Encoding Table for a Port of a provider bridge."
|
|
|
|
OBJECT ieee8021BridgePortNumTrafficClasses
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT ieee8021BridgeTrafficClass
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT ieee8021BridgeRegenUserPriority
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ieee8021BridgeCompliances 2 }
|
|
|
|
END
|
|
|