-- Accedian Enterprise Specific MIB
|
|
--
|
|
-- Copyright (c) 2005-2008, Accedian Networks, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- The contents of this document is subject to change without notice.
|
|
--
|
|
|
|
ACD-DESC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Integer32, Unsigned32, Gauge32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, MacAddress
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
acdProducts
|
|
FROM ACCEDIAN-SMI;
|
|
|
|
acdDesc MODULE-IDENTITY
|
|
|
|
LAST-UPDATED "201011100100Z"
|
|
ORGANIZATION "Accedian Networks, Inc."
|
|
CONTACT-INFO
|
|
"Accedian Technical Assistance Center
|
|
Accedian Networks, Inc.
|
|
4878 Levy, suite 202
|
|
Saint-Laurent, Quebec Canada H4R 2P1
|
|
E-mail: support@accedian.com"
|
|
DESCRIPTION
|
|
"The Accedian Networks device Description MIB."
|
|
|
|
REVISION "201011100100Z" -- 10 November 2010
|
|
DESCRIPTION
|
|
"Fix compliance statement."
|
|
|
|
REVISION "201006300100Z" -- 30 june 2010
|
|
DESCRIPTION
|
|
"Revision for 10GE product introduction."
|
|
|
|
REVISION "200902040100Z" -- 4 Feb 2009
|
|
DESCRIPTION
|
|
"Add sysName in power lost (Dying gasp) notification."
|
|
|
|
REVISION "200812010100Z" -- 1 Dec 2008
|
|
DESCRIPTION
|
|
"Add power lost (Dying gasp) notification."
|
|
|
|
REVISION "200608060100Z" -- 6 Aug 2006
|
|
DESCRIPTION
|
|
"Initial version of MIB module ACD-DESC-MIB."
|
|
|
|
::= { acdProducts 1 }
|
|
|
|
acdDescNotifications OBJECT IDENTIFIER ::= { acdDesc 0 }
|
|
acdDescMIBObjects OBJECT IDENTIFIER ::= { acdDesc 15 }
|
|
acdDescConformance OBJECT IDENTIFIER ::= { acdDescMIBObjects 1 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- EtherNID General information
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescCommercialName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string is to describe the type of device."
|
|
::= { acdDesc 1 }
|
|
|
|
acdDescMacBaseAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Base of the EtherNID MAC addresses."
|
|
::= { acdDesc 2 }
|
|
|
|
acdDescIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the EtherNID on your network."
|
|
::= { acdDesc 3 }
|
|
|
|
acdDescFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the version of the firmware currently loaded."
|
|
::= { acdDesc 4 }
|
|
|
|
acdDescHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the assembly ID of the hardware."
|
|
::= { acdDesc 5 }
|
|
|
|
acdDescSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the serial number."
|
|
::= { acdDesc 6 }
|
|
|
|
acdDescCpuUsageCurrent OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current percentage of CPU usage."
|
|
::= { acdDesc 20 }
|
|
|
|
acdDescCpuUsageAverage15 OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the average percentage of CPU usage over the last 15 seconds.
|
|
This object range from (0..100)."
|
|
::= { acdDesc 21 }
|
|
|
|
acdDescCpuUsageAverage30 OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the average percentage of CPU usage over the last 30 seconds.
|
|
This object range from (0..100)."
|
|
::= { acdDesc 22 }
|
|
|
|
acdDescCpuUsageAverage60 OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the average percentage of CPU usage over the last 60 seconds.
|
|
This object range from (0..100)."
|
|
::= { acdDesc 23 }
|
|
|
|
acdDescCpuUsageAverage900 OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the average percentage of CPU usage over the last 900
|
|
seconds. This object range from (0..100)."
|
|
::= { acdDesc 24 }
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
-- The connector table
|
|
-- This table contains all the information related to the connector.
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescConnectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcdDescConnectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of all connectors info"
|
|
::= { acdDesc 10 }
|
|
|
|
acdDescConnectorEntry OBJECT-TYPE
|
|
SYNTAX AcdDescConnectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the product connector definition."
|
|
INDEX { acdDescConnectorID }
|
|
::= { acdDescConnectorTable 1 }
|
|
|
|
|
|
AcdDescConnectorEntry ::= SEQUENCE {
|
|
acdDescConnectorID Unsigned32,
|
|
acdDescConnectorName DisplayString,
|
|
acdDescConnectorType INTEGER,
|
|
acdDescConnectorPoESupport TruthValue
|
|
}
|
|
|
|
acdDescConnectorID OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique value for each connector. Starting to one from left to right."
|
|
::= { acdDescConnectorEntry 1 }
|
|
|
|
acdDescConnectorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the connector on the silkscreen."
|
|
::= { acdDescConnectorEntry 2 }
|
|
|
|
acdDescConnectorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
rj45(2),
|
|
rj45S(3), -- rj45 shielded
|
|
db9(4),
|
|
bnc(5),
|
|
fAUI(6), -- female aui
|
|
mAUI(7), -- male aui
|
|
fiberSC(8),
|
|
fiberMIC(9),
|
|
fiberST(10),
|
|
telco(11),
|
|
mtrj(12), -- fiber MT-RJ
|
|
hssdc(13), -- fiber channel style-2
|
|
fiberLC(14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describe the connector type, for instance an RJ-45 or an SFP."
|
|
::= { acdDescConnectorEntry 3 }
|
|
|
|
acdDescConnectorPoESupport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the port support PoE or not."
|
|
::= { acdDescConnectorEntry 4 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- The Power Supply table
|
|
-- This table contains all the information related to the Power supplies.
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescPwrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcdDescPwrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of all Power Supplies"
|
|
::= { acdDesc 11 }
|
|
|
|
acdDescPwrEntry OBJECT-TYPE
|
|
SYNTAX AcdDescPwrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the product available power supplies information."
|
|
INDEX { acdDescPwrID }
|
|
::= { acdDescPwrTable 1 }
|
|
|
|
|
|
AcdDescPwrEntry ::= SEQUENCE {
|
|
acdDescPwrID Unsigned32,
|
|
acdDescPwrName DisplayString,
|
|
acdDescPwrType INTEGER,
|
|
acdDescPwrPresent TruthValue
|
|
}
|
|
|
|
acdDescPwrID OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique value for each power supply."
|
|
::= { acdDescPwrEntry 1 }
|
|
|
|
acdDescPwrName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the power supply."
|
|
::= { acdDescPwrEntry 2 }
|
|
|
|
acdDescPwrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pwrplus5volts(1),
|
|
pwrminus48volts(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describe the Power Supply type."
|
|
::= { acdDescPwrEntry 3 }
|
|
|
|
acdDescPwrPresent OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the power supply is present or not."
|
|
::= { acdDescPwrEntry 4 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- The Temperature sensor table
|
|
-- This table contains all the information for the Temperature sensors.
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescTsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcdDescTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of all Teperature Sensors."
|
|
::= { acdDesc 12 }
|
|
|
|
acdDescTsEntry OBJECT-TYPE
|
|
SYNTAX AcdDescTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the product available Temperature sensor information."
|
|
INDEX { acdDescTsID }
|
|
::= { acdDescTsTable 1 }
|
|
|
|
|
|
AcdDescTsEntry ::= SEQUENCE {
|
|
acdDescTsID Unsigned32,
|
|
acdDescTsCurrentTemp Integer32,
|
|
acdDescTsFirstThres Integer32,
|
|
acdDescTsFisrtThresPass TruthValue,
|
|
acdDescTsSecondThres Integer32,
|
|
acdDescTsSecondThresPass TruthValue
|
|
}
|
|
|
|
acdDescTsID OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique value for each Temperature Sensor."
|
|
::= { acdDescTsEntry 1 }
|
|
|
|
acdDescTsCurrentTemp OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current temperature in Celsius around the temperature sensor."
|
|
::= { acdDescTsEntry 2 }
|
|
|
|
acdDescTsFirstThres OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature value in Celsius to declare this threshold crossed."
|
|
::= { acdDescTsEntry 3 }
|
|
|
|
acdDescTsFisrtThresPass OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the temperature cross the first threshold."
|
|
::= { acdDescTsEntry 4 }
|
|
|
|
acdDescTsSecondThres OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature value in Celsius to declare this second threshold crossed."
|
|
::= { acdDescTsEntry 5 }
|
|
|
|
acdDescTsSecondThresPass OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the temperature cross the second threshold."
|
|
::= { acdDescTsEntry 6 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- NOTIFICATIONS (TRAPS)
|
|
-- ****************************************************************************
|
|
|
|
acdPowerLost NOTIFICATION-TYPE
|
|
OBJECTS { acdDescCommercialName,
|
|
acdDescMacBaseAddr,
|
|
acdDescIdentifier,
|
|
acdDescSerialNumber,
|
|
sysName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP trap that is generated by a unit when it detect a power lost.
|
|
It's the equivalent of the 802.3ah dying gasp."
|
|
|
|
::= { acdDescNotifications 1 }
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
-- ACD-DESC-MIB Module - Conformance Information
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescCompliances OBJECT IDENTIFIER ::= { acdDescConformance 1 }
|
|
acdDescGroups OBJECT IDENTIFIER ::= { acdDescConformance 2 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- Units of conformance
|
|
---------------------------------------------------------------------------
|
|
|
|
acdDescGenGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdDescCommercialName,
|
|
acdDescMacBaseAddr,
|
|
acdDescIdentifier,
|
|
acdDescFirmwareVersion,
|
|
acdDescHardwareVersion,
|
|
acdDescSerialNumber,
|
|
acdDescCpuUsageCurrent,
|
|
acdDescCpuUsageAverage15,
|
|
acdDescCpuUsageAverage30,
|
|
acdDescCpuUsageAverage60,
|
|
acdDescCpuUsageAverage900
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdDescGroups 1 }
|
|
|
|
acdDescConnectorGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdDescConnectorName,
|
|
acdDescConnectorType,
|
|
acdDescConnectorPoESupport
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdDescGroups 2 }
|
|
|
|
acdDescPwrGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdDescPwrName,
|
|
acdDescPwrType,
|
|
acdDescPwrPresent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdDescGroups 3 }
|
|
|
|
acdDescTsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdDescTsCurrentTemp,
|
|
acdDescTsFirstThres,
|
|
acdDescTsFisrtThresPass,
|
|
acdDescTsSecondThres,
|
|
acdDescTsSecondThresPass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdDescGroups 4 }
|
|
|
|
acdDescNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
acdPowerLost
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the Notifications group."
|
|
::= { acdDescGroups 5 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- MIB Module Compliance statements
|
|
---------------------------------------------------------------------------
|
|
acdAlarmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for support of the ACD-DESC-MIB module."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
acdDescGenGroup,
|
|
acdDescConnectorGroup,
|
|
acdDescPwrGroup,
|
|
acdDescTsGroup,
|
|
acdDescNotificationsGroup
|
|
}
|
|
|
|
::= { acdDescCompliances 1 }
|
|
|
|
END
|