184 lines
5.8 KiB
Plaintext
184 lines
5.8 KiB
Plaintext
-- ============================================================================
|
|
-- AT-ETH.MIB, Allied Telesis enterprise MIB: LOADER module
|
|
--
|
|
-- Extracted from ATROUTER.MIB of pre 2.9.1 release
|
|
--
|
|
-- June 2006, Stan Xiang
|
|
--
|
|
-- Copyright (c) 2006 by Allied Telesis, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ============================================================================
|
|
|
|
AT-LOADER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
DisplayString,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
|
|
ifIndex
|
|
FROM IF-MIB
|
|
|
|
modules,
|
|
DisplayStringUnsized
|
|
FROM AT-SMI-MIB
|
|
;
|
|
|
|
loader MODULE-IDENTITY
|
|
LAST-UPDATED "200702071010Z"
|
|
ORGANIZATION "Allied Telesis, Inc"
|
|
CONTACT-INFO
|
|
"http://www.alliedtelesis.com"
|
|
|
|
DESCRIPTION
|
|
"To handle upload, object loadStatus is upgraded, as well as the
|
|
description for objects loadServer and loadFilename."
|
|
|
|
REVISION "200702071010Z"
|
|
|
|
DESCRIPTION
|
|
"This MIB file contains definitions of managed objects for the
|
|
LOAD module. "
|
|
|
|
REVISION "200606281222Z"
|
|
DESCRIPTION
|
|
"Initial Revision"
|
|
|
|
::= { modules 48 }
|
|
|
|
-- The load group. This consists of a static and dynamic entry of load
|
|
-- information and a load status variable.
|
|
|
|
-- The load table. This consists of a static and dynamic entry of load
|
|
-- information. The static information will be used if there is no dynamic
|
|
-- information available.
|
|
|
|
loadTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of load parameters, dynamic and static."
|
|
::= { loader 1 }
|
|
|
|
loadEntry OBJECT-TYPE
|
|
SYNTAX LoadEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single entry of load parameters. This contains the
|
|
parameters required to perform a load from the router."
|
|
INDEX { loadIndex }
|
|
::= { loadTable 1 }
|
|
|
|
LoadEntry ::=
|
|
SEQUENCE {
|
|
loadIndex
|
|
INTEGER,
|
|
loadServer
|
|
IpAddress,
|
|
loadDestination
|
|
INTEGER,
|
|
loadFilename
|
|
DisplayString,
|
|
loadDelay
|
|
INTEGER
|
|
}
|
|
|
|
loadIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dynamic(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There are two sets of load information, dynamic and static.
|
|
The dynamic information is used once, then cleared. The static
|
|
information is used whenever the dynamic information is not
|
|
available. The dynamic information is also used to indicate the
|
|
current load parameters when a load is in progress."
|
|
::= { loadEntry 1 }
|
|
|
|
loadServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address from which load will load or upload."
|
|
::= { loadEntry 2 }
|
|
|
|
loadDestination OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
undefined(1),
|
|
nvs(2),
|
|
flash(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination of the file loaded, either flash or nvs
|
|
memory, or undefined."
|
|
::= { loadEntry 3 }
|
|
|
|
loadFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file name of the file being loaded or uploaded."
|
|
::= { loadEntry 4 }
|
|
|
|
loadDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A delay in seconds between the initiation of the load and the
|
|
start of the load. This allows for time to set up TFTP servers
|
|
in cases where the terminal and TFTP server are using the same
|
|
piece of equipment but will not work simultaneously."
|
|
::= { loadEntry 5 }
|
|
|
|
-- The load status value. This is used to start and reset a load, and to
|
|
-- report on the progress of a load.
|
|
|
|
loadStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(1), -- loader is doing nothing
|
|
wait(2), -- loader is waiting to start
|
|
loading(3), -- loader is loading a file
|
|
complete(4), -- loader has successfully completed a load
|
|
reset(5), -- loader was aborted
|
|
actionload(6), -- cause a load to start
|
|
actionstop(7), -- cause a load/upload to stop
|
|
actionupload(8) -- cause a upload to start
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status and action object for the load module. The values 1 to
|
|
5 are read-only values and reflect the state of the load
|
|
module. Values 4 and 5 (complete and reset) are 'read-once',
|
|
that is, if their values are read, either by SNMP or by manager
|
|
console command, then they will be changed back to idle(1). The
|
|
action values (6,7,8) cause a start and stop of the load/upload
|
|
process respectively. Starting the load/upload can only occur if this
|
|
field has the values 1, 4, or 5. Stopping the load can only
|
|
occur is this field has the values 2 or 3. Reading the value of
|
|
the loadStatus after one of actionstart or actionstop has been
|
|
set will give one of the values 1 to 5.
|
|
Note: A single exception to the above rules is that if the value
|
|
of loadStatus is idle(1), then a write of 1 to this variable will
|
|
succeed without generating an error. This exception is to allow
|
|
certain SNMP test suites to test this variable without throwing
|
|
up errors."
|
|
::= { loader 2 }
|
|
END
|