-- AT-QOS.MIB, Allied Telesis enterprise MIB: Quality Of Service module
--
-- Copied from ATR-QOS.MIB of pre 2.9.1 release
--
-- Copyright (c) 2006 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================
AT-QOS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Counter64,
Integer32,
Gauge32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
modules
FROM AT-SMI-MIB
;
qos MODULE-IDENTITY
LAST-UPDATED "200412011525Z"
ORGANIZATION "Allied Telesis, Inc"
CONTACT-INFO
"http://www.alliedtelesis.com"
DESCRIPTION
"This MIB file contains definitions of managed objects for the
handling QoS on Allied Telesis switches. There are a
number of tables designed to be generic to
all ATR switches supporting QoS in silicon, and well as tables for
specific AT switches or switch familes."
REVISION "200412011525Z"
DESCRIPTION
"Initial Revision"
::= { modules 99 }
-- ============================================================================
-- ============================================================================
-- QoS Switch group
-- ============================================================================
-- ============================================================================
qosSwitch OBJECT IDENTIFIER ::= { qos 1 }
-- =================================================
-- QoS Switch Port table
-- =================================================
qosSwitchPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosSwitchPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Generic port configuration for QoS, indexed by port index."
::= { qosSwitch 1 }
qosSwitchPortEntry OBJECT-TYPE
SYNTAX QosSwitchPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single switch port entry for QoS."
INDEX { qosSwitchPortIndex }
::= { qosSwitchPortTable 1 }
QosSwitchPortEntry ::=
SEQUENCE {
qosSwitchPortIndex
Integer32,
qosSwitchPortPolicyIndex
Integer32
}
qosSwitchPortIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port index of the port entry. This index is the same port number
used in CLI commands, and the same index as appears in other MIB
tables related to switch ports."
::= { qosSwitchPortEntry 1 }
qosSwitchPortPolicyIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Policy index of the policy for this port. Policy index numbers for
CLI commands start at 0, while SNMP indexes must start at 1. This
means that the policy index in this MIB variable is 1 more than the
index for the same policy as entered for CLI commands."
::= { qosSwitchPortEntry 2 }
-- ============================================================================
-- Policy table
-- ============================================================================
qosSwitchPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosSwitchPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"QoS policy configuration, indexed by policy index."
::= { qosSwitch 2 }
qosSwitchPolicyEntry OBJECT-TYPE
SYNTAX QosSwitchPolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A policy entry containing configuration information for
a single policy."
INDEX { qosSwitchPolicyIndex }
::= { qosSwitchPolicyTable 1 }
QosSwitchPolicyEntry ::=
SEQUENCE {
qosSwitchPolicyIndex
Integer32,
qosSwitchPolicyDescription
OCTET STRING,
qosSwitchPolicyDefaultTCDropBWClass3
INTEGER,
qosSwitchPolicyDefaultTCIgnoreBWClass
INTEGER,
qosSwitchPolicyDefaultTCMarkValue
Integer32,
qosSwitchPolicyDefaultTCMaxBandwidth
Integer32,
qosSwitchPolicyDefaultTCMaxBurstSize
Integer32,
qosSwitchPolicyDefaultTCMinBandwidth
Integer32,
qosSwitchPolicyDefaultTCMinBurstSize
Integer32,
qosSwitchPolicyDefaultTCPremarking
INTEGER,
qosSwitchPolicyDefaultTCRemarking
INTEGER
}
qosSwitchPolicyIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of this policy entry. Policy index numbers for
CLI commands start at 0, while SNMP indexes must start at 1. This
means that the policy index in this MIB variable is 1 more than the
index for the same policy as entered for CLI commands."
::= { qosSwitchPolicyEntry 1 }
qosSwitchPolicyDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An optional description for the policy, as entered via the CLI."
::= { qosSwitchPolicyEntry 2 }
qosSwitchPolicyDefaultTCDropBWClass3 OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether traffic that exceeds the bandwidth for the
default traffic class be dropped or not. The bandwidth limit is the
combined total of the variables qosSwitchPolicyDefaultTCMaxBandwidth
and qosSwitchPolicyDefaultTCMaxBurstSize. A value of yes(1) indicates
that traffic exceeding the bandwidth limit is dropped immediately. A
value of no(0) indicates that the excess traffic is marked as
bandwidth class 3 and is therefore eligible for dropping by the RED
curve settings."
::= { qosSwitchPolicyEntry 3 }
qosSwitchPolicyDefaultTCIgnoreBWClass OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the traffic metering stage acknowledges any
bandwidth class assigned to flows processed by the default traffic
class. If set to yes(1), previously assigned bandwidth classes will
be ignored will be ignored and the bandwidth class of the traffic
will be set according to the meter conformance level of the flow."
::= { qosSwitchPolicyEntry 4 }
qosSwitchPolicyDefaultTCMarkValue OBJECT-TYPE
SYNTAX Integer32 (0..63 | 256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the qosSwitchPolicyDefaultTCPremarking variable is set to
usemarkvalue(1), this variable specifies the index into the DSCP
MAP table to use for remarking. A value in the range 0 to 63
indicates the DSCP to use, the value 256 indicates that no DSCP
value has been defined for the default traffic class for this policy."
::= { qosSwitchPolicyEntry 5 }
qosSwitchPolicyDefaultTCMaxBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000 | 2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum bandwidth available to the default traffic
class. Traffic under this bandwidth will be designated as bandwidth
class 2. The value 2147483647 indicates that there is no limit on
the maximum bandwidth for the default traffic class for this
policy."
::= { qosSwitchPolicyEntry 6 }
qosSwitchPolicyDefaultTCMaxBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum bandwidth above the bandwidth specified by
qosSwitchPolicyDefaultTCMaxBandwidth before traffic is marked as
bandwidth class 3."
::= { qosSwitchPolicyEntry 7 }
qosSwitchPolicyDefaultTCMinBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000 | 2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the minimum bandwidth reserved for the default traffic
class. Traffic under this bandwidth will be marked as bandwidth
class 1. The value 2147483647 indicates that there is no limit on
the minimum bandwidth for the default traffic class for this
policy."
::= { qosSwitchPolicyEntry 8 }
qosSwitchPolicyDefaultTCMinBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum amount of data above the bandwidth specified
in the variable qosSwitchPolicyDefaultTCMinBandwidth before traffic
is marked as bandwidth class 2."
::= { qosSwitchPolicyEntry 9 }
qosSwitchPolicyDefaultTCPremarking OBJECT-TYPE
SYNTAX INTEGER {
none(0),
usemarkvalue(1),
usedscp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the QoS action to take on traffic in the default traffic
class before metering actions are taken. If none(0) is specified,
the traffic is passed to the metering stage. If usemarkvalue(1) is
specified, the QoS settings are taken from the variable
qosSwitchPolicyDefaultTCMarkValue used as an index into the DCSP
MAP table. If usedscp(2) is specified, the DSCP value in the data
frames is used as an index into the DSCP MAP table."
::= { qosSwitchPolicyEntry 10 }
qosSwitchPolicyDefaultTCRemarking OBJECT-TYPE
SYNTAX INTEGER {
none(0),
usedscpmap(1),
bwclass(2),
priority(3),
bwclass_priority(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the action to take after the metering stage for traffic
in the default traffic class. The metering stage assigns a
temporary value of bandwidth class to the flow which is used to
determine its per-hop behaviour. If this variable is set to
bwclass(2) or bwclass_priority(4), the temporary bandwidth class
becomes the new bandwidth class for the flow. If priority(3) or
bwclass_priority(4) is specified, the currently
assigned queue for frames in this traffic class is used in
conjunction with the temporary bandwidth class to determine the new
value of the VLAN Tag User Priority field. If usedscpmap(1) is
specified, the temporary value is used (in conjunction with the
DSCP of the frame) as an index into the DSCP MAP table, which then
assigns the actual, new values for bandwidth class, DSCP, Egress
Queue and VLAN Tag User Priority. A value of none(0) for this
variable means that no remarking of the packet is done after the
metering stage."
::= { qosSwitchPolicyEntry 11 }
-- ============================================================================
-- Traffic Class table
-- ============================================================================
qosSwitchTrafficClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosSwitchTrafficClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Traffic class configuration, indexed by traffic class index."
::= { qosSwitch 3 }
qosSwitchTrafficClassEntry OBJECT-TYPE
SYNTAX QosSwitchTrafficClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A traffic class entry containing configuration information for
a single traffic class."
INDEX { qosSwitchTrafficClassIndex }
::= { qosSwitchTrafficClassTable 1 }
QosSwitchTrafficClassEntry ::=
SEQUENCE {
qosSwitchTrafficClassIndex
Integer32,
qosSwitchTrafficClassPolicyNumber
Integer32,
qosSwitchTrafficClassDescription
OCTET STRING,
qosSwitchTrafficClassDropBWClass3
INTEGER,
qosSwitchTrafficClassIgnoreBWClass
INTEGER,
qosSwitchTrafficClassMarkValue
Integer32,
qosSwitchTrafficClassMaxBandwidth
Integer32,
qosSwitchTrafficClassMaxBurstSize
Integer32,
qosSwitchTrafficClassMinBandwidth
Integer32,
qosSwitchTrafficClassMinBurstSize
Integer32,
qosSwitchTrafficClassPremarking
INTEGER,
qosSwitchTrafficClassRemarking
INTEGER
}
qosSwitchTrafficClassIndex OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of this traffic class entry. Traffic class index numbers
for CLI commands start at 0, while SNMP indexes must start at 1.
This means that the traffic class index in this MIB variable is 1
more than the index for the same traffic class as entered for CLI
commands."
::= { qosSwitchTrafficClassEntry 1 }
qosSwitchTrafficClassPolicyNumber OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Policy index of the policy to which this traffic class belongs.
Policy index numbers for CLI commands start at 0, while SNMP
indexes must start at 1. This means that the policy index in this
MIB variable is 1 more than the index for the same policy as
entered for CLI commands. A value of 0 for this variable means
that the traffic class has not been added to a policy yet."
::= { qosSwitchTrafficClassEntry 2 }
qosSwitchTrafficClassDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An optional description for this traffic class."
::= { qosSwitchTrafficClassEntry 3 }
qosSwitchTrafficClassDropBWClass3 OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether traffic that exceeds the bandwidth for
this traffic class be dropped or not. The bandwidth limit is the
combined total of the variables qosSwitchTrafficClassMaxBandwidth
and qosSwitchTrafficClassMaxBurstSize A value of yes(1) indicates
that traffic exceeding the bandwidth limit is dropped immediately. A
value of no(0) indicates that the excess traffic is marked as
bandwidth class 3 and is therefore eligible for dropping by the RED
curve settings."
::= { qosSwitchTrafficClassEntry 4 }
qosSwitchTrafficClassIgnoreBWClass OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the traffic metering stage acknowledges any
bandwidth class assigned to flows processed by this traffic
class. If set to yes(1), previously assigned bandwidth classes will
be ignored will be ignored and the bandwidth class of the traffic
will be set according to the meter conformance level of the flow."
::= { qosSwitchTrafficClassEntry 5 }
qosSwitchTrafficClassMarkValue OBJECT-TYPE
SYNTAX Integer32 (0..63 | 256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the qosSwitchTrafficClassPremarking variable is set to
usemarkvalue(1), this variable specifies the index into the DSCP
MAP table to use for remarking. A value in the range 0 to 63
indicates the DSCP to use, the value 256 indicates that no DSCP
value has been defined for this traffic class."
::= { qosSwitchTrafficClassEntry 6 }
qosSwitchTrafficClassMaxBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000 | 2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum bandwidth available to this traffic
class. Traffic under this bandwidth will be designated as bandwidth
class 2. The value 2147483647 indicates that there is no limit on
the maximum bandwidth for this traffic class."
::= { qosSwitchTrafficClassEntry 7 }
qosSwitchTrafficClassMaxBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum bandwidth above the bandwidth specified by
qosSwitchTrafficClassMaxBandwidth before traffic is marked as
bandwidth class 3."
::= { qosSwitchTrafficClassEntry 8 }
qosSwitchTrafficClassMinBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000 | 2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the minimum bandwidth reserved for this traffic
class. Traffic under this bandwidth will be marked as bandwidth
class 1. The value 2147483647 indicates that there is no limit on
the minimum bandwidth for this traffic class."
::= { qosSwitchTrafficClassEntry 9 }
qosSwitchTrafficClassMinBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum amount of data above the bandwidth specified
in the variable qosSwitchTrafficClassMinBandwidth before traffic
is marked as bandwidth class 2."
::= { qosSwitchTrafficClassEntry 10 }
qosSwitchTrafficClassPremarking OBJECT-TYPE
SYNTAX INTEGER {
none(0),
usemarkvalue(1),
usedscp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the QoS action to take on traffic in this traffic
class before metering actions are taken. If none(0) is specified,
the traffic is passed to the metering stage. If usemarkvalue(1) is
specified, the QoS settings are taken from the variable
qosSwitchTrafficClassMarkValue used as an index into the DCSP
MAP table. If usedscp(2) is specified, the DSCP value in the data
frames is used as an index into the DSCP MAP table."
::= { qosSwitchTrafficClassEntry 11 }
qosSwitchTrafficClassRemarking OBJECT-TYPE
SYNTAX INTEGER {
none(0),
usedscpmap(1),
bwclass(2),
priority(3),
bwclass_priority(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the action to take after the metering stage for traffic
in this traffic class. The metering stage assigns a
temporary value of bandwidth class to the flow which is used to
determine its per-hop behaviour. If this variable is set to
bwclass(2) or bwclass_priority(3), the temporary bandwidth class
becomes the new bandwidth class for the flow. If priority(3) or
bwclass_priority(4) is specified, the currently
assigned queue for frames in this traffic class is used in
conjunction with the temporary bandwidth class to determine the new
value of the VLAN Tag User Priority field. If usedscpmap(1) is
specified, the temporary value is used (in conjunction with the
DSCP of the frame) as an index into the DSCP MAP table, which then
assigns the actual, new values for bandwidth class, DSCP, Egress
Queue and VLAN Tag User Priority. A value of none(0) for this
variable means that no remarking of the packet is done after the
metering stage."
::= { qosSwitchTrafficClassEntry 12 }
-- ============================================================================
-- ============================================================================
-- 8948 specific stuff. The tables in this section are specific to the 8948
-- switch, because they relate directly to the hardware used in this switch.
-- Other switches that use the same hardware will also support this MIB table.
-- ============================================================================
-- ============================================================================
qosSwitch8948 OBJECT IDENTIFIER ::= { qosSwitch 4 }
-- ============================================================================
-- 8948 port table - 8948 specific extensions to the qosSwitchPortTable
-- ============================================================================
qosSwitch8948PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosSwitch8948PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port configuration, indexed by port index."
::= { qosSwitch8948 1 }
qosSwitch8948PortEntry OBJECT-TYPE
SYNTAX QosSwitch8948PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single switch port entry."
AUGMENTS { qosSwitchPortEntry }
::= { qosSwitch8948PortTable 1 }
QosSwitch8948PortEntry ::=
SEQUENCE {
qosSwitch8948PortDefaultTCCountersAggregateBytes
Counter64,
qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes
Counter64,
qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes
Counter64,
qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes
Counter64,
qosSwitch8948PortDefaultTCCountersDroppedBytes
Counter64,
qosSwitch8948PortQueueLength
Gauge32,
qosSwitch8948PortQueue0Length
Gauge32,
qosSwitch8948PortQueue1Length
Gauge32,
qosSwitch8948PortQueue2Length
Gauge32,
qosSwitch8948PortQueue3Length
Gauge32,
qosSwitch8948PortQueue4Length
Gauge32,
qosSwitch8948PortQueue5Length
Gauge32,
qosSwitch8948PortQueue6Length
Gauge32,
qosSwitch8948PortQueue7Length
Gauge32
}
qosSwitch8948PortDefaultTCCountersAggregateBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes classified by the default traffic class
on this port."
::= { qosSwitch8948PortEntry 1 }
qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by the default traffic class on
this port conforming to bandwidth class 1."
::= { qosSwitch8948PortEntry 2 }
qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by the default traffic class on
this port conforming to bandwidth class 2."
::= { qosSwitch8948PortEntry 3 }
qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by the default traffic class on
this port conforming to bandwidth class 3."
::= { qosSwitch8948PortEntry 4 }
qosSwitch8948PortDefaultTCCountersDroppedBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes dropped by the default traffic class on
this port."
::= { qosSwitch8948PortEntry 5 }
qosSwitch8948PortQueueLength OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets currently queued for transmission on
this port."
::= { qosSwitch8948PortEntry 6 }
qosSwitch8948PortQueue0Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 0.
The numbering of queues indicates the priority of handling the
traffic in that queue, with the higher queue number getting
higher priority. The priority values in packets are mapped to
queues via a priority to queue mapping. The default priority to
queue mapping is as follows:
Priority Queue
value number
7 7
6 6
5 5
4 4
3 3
2 1
1 0
0 2
This mapping allows the default priority value of 0 to map to a
queue which is not the lowest priority queue, allowing traffic
classes to be assigned a lower priority queue than the default."
::= { qosSwitch8948PortEntry 7 }
qosSwitch8948PortQueue1Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 1. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 8 }
qosSwitch8948PortQueue2Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 2. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 9 }
qosSwitch8948PortQueue3Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 3. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 10 }
qosSwitch8948PortQueue4Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 4. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 11 }
qosSwitch8948PortQueue5Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 5. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 12 }
qosSwitch8948PortQueue6Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 6. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 13 }
qosSwitch8948PortQueue7Length OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently queued for transmission on this
port in queue 7. See the description for qosSwitch8948PortQueue0Length
to understand the meaning of queue numbers."
::= { qosSwitch8948PortEntry 14 }
-- ============================================================================
-- Traffic Class counters table
-- ============================================================================
qosSwitch8948TrafficClassCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosSwitch8948TrafficClassCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Traffic class counters indexed by port, policy and traffic
class."
::= { qosSwitch8948 2 }
qosSwitch8948TrafficClassCountersEntry OBJECT-TYPE
SYNTAX QosSwitch8948TrafficClassCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A traffic class counters entry containing QOS counters for a
particular port, policy and traffic class."
INDEX { qosSwitch8948TCCountersPortIndex,
qosSwitch8948TCCountersPolicyIndex,
qosSwitch8948TCCountersTrafficClassIndex }
::= { qosSwitch8948TrafficClassCountersTable 1 }
QosSwitch8948TrafficClassCountersEntry ::=
SEQUENCE {
qosSwitch8948TCCountersPortIndex
Integer32,
qosSwitch8948TCCountersPolicyIndex
Integer32,
qosSwitch8948TCCountersTrafficClassIndex
Integer32,
qosSwitch8948TCCountersAggregateBytes
Counter32,
qosSwitch8948TCCountersBwConformanceClass1Bytes
Counter32,
qosSwitch8948TCCountersBwConformanceClass2Bytes
Counter32,
qosSwitch8948TCCountersBwConformanceClass3Bytes
Counter32,
qosSwitch8948TCCountersDroppedBytes
Counter32
}
qosSwitch8948TCCountersPortIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the port for this entry in the traffic class
counter table. This index is the same as the port index in the
port table and is the same as the port number of the port in
user commands."
::= { qosSwitch8948TrafficClassCountersEntry 1 }
qosSwitch8948TCCountersPolicyIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the policy for this entry in the traffic class
counter table. Each port can only have one policy assigned at a
time. Policy index numbers for CLI commands start at 0, while SNMP
indexes must start at 1. This means that the policy index in this
MIB variable is 1 more than the index for the same policy as
entered for CLI commands."
::= { qosSwitch8948TrafficClassCountersEntry 2 }
qosSwitch8948TCCountersTrafficClassIndex OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the traffic class for this entry in the traffic
class counter table. The index is one of the indices defined for
traffic classes for this port and policy. Traffic class indices
for CLI commands start at 0, while SNMP indices must start at 1.
This means that the traffic class index in this MIB variable is 1
more than the index for the same traffic class as entered for CLI
commands."
::= { qosSwitch8948TrafficClassCountersEntry 3 }
qosSwitch8948TCCountersAggregateBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes classified by this traffic class for
this policy on this port."
::= { qosSwitch8948TrafficClassCountersEntry 4 }
qosSwitch8948TCCountersBwConformanceClass1Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by this traffic class for this
policy on this port conforming to bandwidth class 1."
::= { qosSwitch8948TrafficClassCountersEntry 5 }
qosSwitch8948TCCountersBwConformanceClass2Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by this traffic class for this
policy on this port conforming to bandwidth class 2."
::= { qosSwitch8948TrafficClassCountersEntry 6 }
qosSwitch8948TCCountersBwConformanceClass3Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes classified by this traffic class for this
policy on this port conforming to bandwidth class 3."
::= { qosSwitch8948TrafficClassCountersEntry 7 }
qosSwitch8948TCCountersDroppedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes dropped by this traffic class for this
policy on this port."
::= { qosSwitch8948TrafficClassCountersEntry 8 }
END