mibs/MIBS/arris/DOCS-TEST-MIB
2023-12-05 12:25:34 +01:00

183 lines
6.2 KiB
Plaintext

DOCS-TEST-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
-- do not import BITS,
Integer32,
enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF;
-- These are the defined Cablelabs OID paths. Not all are needed for the Test MIB,
-- but included here for sake of completeness.
cableLabs OBJECT IDENTIFIER ::= { enterprises 4491 }
clabFunction OBJECT IDENTIFIER ::= { cableLabs 1 }
clabFuncMib2 OBJECT IDENTIFIER ::= { clabFunction 1 }
clabFuncProprietary OBJECT IDENTIFIER ::= { clabFunction 2 }
clabProject OBJECT IDENTIFIER ::= { cableLabs 2 }
clabProjDocsis OBJECT IDENTIFIER ::= { clabProject 1 }
clabProjPacketCable OBJECT IDENTIFIER ::= { clabProject 2 }
clabProjOpenCable OBJECT IDENTIFIER ::= { clabProject 3 }
clabProjCableHome OBJECT IDENTIFIER ::= { clabProject 4 }
docsTestMIB MODULE-IDENTITY
LAST-UPDATED "0203150000Z" -- March 15, 2002
ORGANIZATION "DOCSIS 2.0 ATP Working Group"
CONTACT-INFO
" David Raftus
Postal: Imedia Semiconductor
340 Terry Fox Drive, Suite 202
Ottawa Ontario
Canada
Phone: +1 613 592 1052
E-mail: david.raftus@imedia.com
DOCSIS 2.0 ATP Working Group
General Discussion: docsis-20@cablelabs.com,
docsis-20-atp@cablelabs.com"
DESCRIPTION
"This is the MIB Module supporting programmable test features
for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
Termination Systems (CMTS)."
-- 4491 is the IANA Cablelabs enterprise number
::= { clabProjDocsis 12 }
-- Textual Conventions
-- none required yet - dave - leave as a placeholder
-- Mapping path to the test mib.
--
docsTestMibObjects OBJECT IDENTIFIER ::= { docsTestMIB 1 }
docsTestBaseObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 1 }
docsTestSetupObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 2 }
--
-- docsTestBaseObjects
--
-- These objects indicate the capability and current status of the
-- programmable test features on the CM/CMTS.
--
docsTestCapability OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ability of this device to support the
programmable features identified by the TYPE field from
the CM/CMTS TLV table in [17] and section 3.1.2.
Each octet within this octet string represents eight tests.
For example, the first octet represents tests one through eight
as identified by the TYPE field."
::= { docsTestBaseObjects 1 }
docsTestStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current operating status of tests initiated
through the docsTestSetupObjects. The octet representation is
identical to that used by docsTestCapability. A bit representation
of one indicates that a test is currently active, while zero
indicates the test is inactive or has completed."
::= { docsTestBaseObjects 2 }
--
-- docsTestSetupObjects
--
-- These objects setup the test parameters ands initiate the test.
--
docsTestType OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Corresponds to the TYPE field from the CM/CMTS TLV Table
in [17] and section 3.1.2. The default value of zero indicates
no test has yet been initiated.
A WrongValueError should be returned in response to a write
request for a test not supported by the device. A read request
will return the docsTestType value last successfully written,
whether that test is active or inactive."
DEFVAL { 0 }
::= { docsTestSetupObjects 1 }
docsTestData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Corresponds to the LENGTH and VALUE fields from the CM/CMTS TLV
Table in [17] and section 3.1.2. A read request will return the
docsTestData value last successfully written, whether that test
is active or inactive."
::= { docsTestSetupObjects 2 }
docsTestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to initiate or stop the tests setup through the docsTestType
and docsTestData objects.
A CommitFailedError should be returned in response to a TRUE
Write request if the values in docsTestType and docsTestData are
incompatible, or a test could not be initiated for any other
reason."
::= { docsTestSetupObjects 3 }
-- Compliance statements
docsTestConformance OBJECT IDENTIFIER ::= { docsTestMIB 2 }
docsTestCompliances OBJECT IDENTIFIER ::= { docsTestConformance 1 }
docsTestGroups OBJECT IDENTIFIER ::= { docsTestConformance 2 }
docsTestBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that implement
the DOCSIS compliant programmable test features."
MODULE -- docsTestMib
-- unconditionally mandatory groups
MANDATORY-GROUPS {
docsTestGroup
} ::= { docsTestCompliances 1 }
docsTestGroup OBJECT-GROUP
OBJECTS {
docsTestCapability,
docsTestStatus,
docsTestType,
docsTestData,
docsTestEnable
}
STATUS current
DESCRIPTION
"Group of objects implemented in both Cable Modems and
Cable Modem Termination Systems."
::= { docsTestGroups 1 }
END