AC-PM-ATM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
enterprises FROM SNMPv2-SMI;
audioCodes OBJECT IDENTIFIER ::= {enterprises 5003}
acRegistrations OBJECT IDENTIFIER ::= {audioCodes 7}
acGeneric OBJECT IDENTIFIER ::= {audioCodes 8}
acProducts OBJECT IDENTIFIER ::= {audioCodes 9}
acPerformance OBJECT IDENTIFIER ::= {audioCodes 10}
acPMAtm MODULE-IDENTITY
LAST-UPDATED "200601261643Z" --Thursday, January 26, 2006
ORGANIZATION "AudioCodes Ltd"
CONTACT-INFO
"Postal: Support
AudioCodes LTD
1 Hayarden Street
Airport City
Lod, ISRAEL 70151
Tel: 972-3-9764000
Fax: 972-3-9764040
Email: support@audiocodes.com
Web: www.audiocodes.com"
DESCRIPTION
"The AC-PM-ATM MIB offers performance monitoring
For the ATMrelated elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-ATM MIB, and the
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.
Note - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."
REVISION "201006041528Z" --Tuesday, April 06, 2010
DESCRIPTION "obsoleted acPMAtm"
::= {acPerformance 12}
acPMAtmConfiguration OBJECT IDENTIFIER ::= {acPMAtm 1}
acPMAtmConfigurationPeriodLength OBJECT-TYPE
SYNTAX INTEGER (0..894780)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Length of monitoring intervals for entire MIB.Time is in minutes."
::= {acPMAtmConfiguration 1}
acPMAtmConfigurationResetTotalCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCountersDone(1)
,
resetTotalCounters(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Total-Counters Reset. To reset the total counters, set the
value of this object to resetTotalCounters(2)."
::= {acPMAtmConfiguration 2}
acPMAtmCellAttributes OBJECT IDENTIFIER ::= {acPMAtmConfiguration 31}
acPMAtmCellAttributesTxHighThreshold OBJECT-TYPE
SYNTAX INTEGER (100..3000)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold."
::= {acPMAtmCellAttributes 1}
acPMAtmCellAttributesTxLowThreshold OBJECT-TYPE
SYNTAX INTEGER (100..3000)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold."
::= {acPMAtmCellAttributes 2}
acPMAtmCellAttributesRxHighThreshold OBJECT-TYPE
SYNTAX INTEGER (100..3000)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold."
::= {acPMAtmCellAttributes 3}
acPMAtmCellAttributesRxLowThreshold OBJECT-TYPE
SYNTAX INTEGER (100..3000)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold."
::= {acPMAtmCellAttributes 4}
acPMAtmData OBJECT IDENTIFIER ::= {acPMAtm 2}
acPMAtmDataAcPMAtmTimeFromStartOfInterval OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The time in seconds since the start of the current interval.
MIB specific."
::= {acPMAtmData 1}
-- ****************************************
-- acPMAtmCellTx table decleration
-- ****************************************
acPMAtmCellTxTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMAtmCellTxEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Atm interface transmit cells per second."
::= {acPMAtmData 21}
-- ****************************************
-- acPMAtmCellTx table entry
-- ****************************************
acPMAtmCellTxEntry OBJECT-TYPE
SYNTAX AcPMAtmCellTxEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMAtmCellTxInterface,acPMAtmCellTxInterval}
::= {acPMAtmCellTxTable 1}
-- ****************************************
-- acPMAtmCellTx TABLE
-- ****************************************
AcPMAtmCellTxEntry ::= SEQUENCE {
acPMAtmCellTxInterface INTEGER,
acPMAtmCellTxInterval INTEGER,
acPMAtmCellTxAverage INTEGER,
acPMAtmCellTxMax INTEGER,
acPMAtmCellTxMin INTEGER,
acPMAtmCellTxVolume Counter32,
acPMAtmCellTxTimeBelowLowThreshold INTEGER,
acPMAtmCellTxTimeBetweenThresholds INTEGER,
acPMAtmCellTxTimeAboveHighThreshold INTEGER,
acPMAtmCellTxFullDayAverage INTEGER
}
acPMAtmCellTxInterface OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Atm interface 0,1 and 2."
::= {acPMAtmCellTxEntry 1}
acPMAtmCellTxInterval OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMAtmCellTxEntry 2}
acPMAtmCellTxAverage OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMAtmCellTxEntry 3}
acPMAtmCellTxMax OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMAtmCellTxEntry 4}
acPMAtmCellTxMin OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMAtmCellTxEntry 5}
acPMAtmCellTxVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMAtmCellTxEntry 6}
acPMAtmCellTxTimeBelowLowThreshold OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is below what was determined
as the low threshold."
::= {acPMAtmCellTxEntry 7}
acPMAtmCellTxTimeBetweenThresholds OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold."
::= {acPMAtmCellTxEntry 8}
acPMAtmCellTxTimeAboveHighThreshold OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
::= {acPMAtmCellTxEntry 9}
acPMAtmCellTxFullDayAverage OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The average of full 24 hours."
::= {acPMAtmCellTxEntry 10}
-- ****************************************
-- acPMAtmCellRx table decleration
-- ****************************************
acPMAtmCellRxTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMAtmCellRxEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Atm interface recieve cells per second."
::= {acPMAtmData 22}
-- ****************************************
-- acPMAtmCellRx table entry
-- ****************************************
acPMAtmCellRxEntry OBJECT-TYPE
SYNTAX AcPMAtmCellRxEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMAtmCellRxInterface,acPMAtmCellRxInterval}
::= {acPMAtmCellRxTable 1}
-- ****************************************
-- acPMAtmCellRx TABLE
-- ****************************************
AcPMAtmCellRxEntry ::= SEQUENCE {
acPMAtmCellRxInterface INTEGER,
acPMAtmCellRxInterval INTEGER,
acPMAtmCellRxAverage INTEGER,
acPMAtmCellRxMax INTEGER,
acPMAtmCellRxMin INTEGER,
acPMAtmCellRxVolume Counter32,
acPMAtmCellRxTimeBelowLowThreshold INTEGER,
acPMAtmCellRxTimeBetweenThresholds INTEGER,
acPMAtmCellRxTimeAboveHighThreshold INTEGER,
acPMAtmCellRxFullDayAverage INTEGER
}
acPMAtmCellRxInterface OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Atm interface 0,1 and 2."
::= {acPMAtmCellRxEntry 1}
acPMAtmCellRxInterval OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMAtmCellRxEntry 2}
acPMAtmCellRxAverage OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMAtmCellRxEntry 3}
acPMAtmCellRxMax OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMAtmCellRxEntry 4}
acPMAtmCellRxMin OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMAtmCellRxEntry 5}
acPMAtmCellRxVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMAtmCellRxEntry 6}
acPMAtmCellRxTimeBelowLowThreshold OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is below what was determined
as the low threshold."
::= {acPMAtmCellRxEntry 7}
acPMAtmCellRxTimeBetweenThresholds OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold."
::= {acPMAtmCellRxEntry 8}
acPMAtmCellRxTimeAboveHighThreshold OBJECT-TYPE
SYNTAX INTEGER (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
::= {acPMAtmCellRxEntry 9}
acPMAtmCellRxFullDayAverage OBJECT-TYPE
SYNTAX INTEGER (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The average of full 24 hours."
::= {acPMAtmCellRxEntry 10}
-- ****************************************
-- acPMAtmCellDiscarded table decleration
-- ****************************************
acPMAtmCellDiscardedTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMAtmCellDiscardedEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Counts the number of cells discarded in the reporting interval."
::= {acPMAtmData 23}
-- ****************************************
-- acPMAtmCellDiscarded table entry
-- ****************************************
acPMAtmCellDiscardedEntry OBJECT-TYPE
SYNTAX AcPMAtmCellDiscardedEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMAtmCellDiscardedInterface,acPMAtmCellDiscardedInterval}
::= {acPMAtmCellDiscardedTable 1}
-- ****************************************
-- acPMAtmCellDiscarded TABLE
-- ****************************************
AcPMAtmCellDiscardedEntry ::= SEQUENCE {
acPMAtmCellDiscardedInterface INTEGER,
acPMAtmCellDiscardedInterval INTEGER,
acPMAtmCellDiscardedVal Gauge32
}
acPMAtmCellDiscardedInterface OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Atm interface 0,1 and 2."
::= {acPMAtmCellDiscardedEntry 1}
acPMAtmCellDiscardedInterval OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMAtmCellDiscardedEntry 2}
acPMAtmCellDiscardedVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMAtmCellDiscardedEntry 3}