mibs/MIBS/audiocodes/AC-PMSS7-MIB
2023-12-05 12:25:34 +01:00

2836 lines
79 KiB
Plaintext

AC-PM-SS7-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TAddress,
DisplayString,
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
IpAddress FROM RFC1155-SMI
Unsigned32,
Integer32,
enterprises FROM SNMPv2-SMI
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
audioCodes,
acRegistrations,
acGeneric,
acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
acPMSS7 MODULE-IDENTITY
LAST-UPDATED "200909231811Z" --Wednesday, September 23, 2009
ORGANIZATION "AudioCodes Ltd"
CONTACT-INFO
"Postal: Support
AudioCodes LTD
1 Hayarden Street
Airport City
Lod, ISRAEL 70151
Tel: 972-3-9764000
Fax: 972-3-9764040
Email: support@audiocodes.com
Web: www.audiocodes.com"
DESCRIPTION
"The AC-PM-SS7 MIB offers performance monitoring
For the SS7 related elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-SS7 MIB, and the
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.
Note - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."
::= {acPerformance 13}
acPMSS7Configuration OBJECT IDENTIFIER ::= {acPMSS7 1}
acPMSS7ConfigurationPeriodLength OBJECT-TYPE
SYNTAX Unsigned32 (0..894780)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Length of monitoring intervals for entire MIB. Time is in minutes.
Access: Online."
::= {acPMSS7Configuration 1}
acPMSS7ConfigurationResetTotalCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCountersDone(1)
,
resetTotalCounters(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Total-Counters Reset. To reset the total counters, set the
value of this object to resetTotalCounters(2).
Access: Online."
::= {acPMSS7Configuration 2}
acPMSS7Data OBJECT IDENTIFIER ::= {acPMSS7 2}
acPMSS7DataTimeFromStartOfInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in seconds since the start of the current interval.
MIB specific."
::= {acPMSS7Data 1}
acPMSS7Links OBJECT IDENTIFIER ::= {acPMSS7Data 31}
-- ****************************************
-- acPMSS7TxMSU table declaration
-- ****************************************
acPMSS7TxMSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted MSU's per SS7 link."
::= {acPMSS7Links 1}
-- ****************************************
-- acPMSS7TxMSU table entry
-- ****************************************
acPMSS7TxMSUEntry OBJECT-TYPE
SYNTAX AcPMSS7TxMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxMSULink,acPMSS7TxMSUInterval}
::= {acPMSS7TxMSUTable 1}
-- ****************************************
-- acPMSS7TxMSU TABLE
-- ****************************************
AcPMSS7TxMSUEntry ::= SEQUENCE {
acPMSS7TxMSULink Unsigned32,
acPMSS7TxMSUInterval Unsigned32,
acPMSS7TxMSUVal Counter32,
acPMSS7TxMSUTotal Integer32
}
acPMSS7TxMSULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7TxMSUEntry 1}
acPMSS7TxMSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxMSUEntry 2}
acPMSS7TxMSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxMSUEntry 3}
acPMSS7TxMSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxMSUEntry 4}
-- ****************************************
-- acPMSS7RxMSU table declaration
-- ****************************************
acPMSS7RxMSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received MSU's per SS7 link."
::= {acPMSS7Links 2}
-- ****************************************
-- acPMSS7RxMSU table entry
-- ****************************************
acPMSS7RxMSUEntry OBJECT-TYPE
SYNTAX AcPMSS7RxMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxMSULink,acPMSS7RxMSUInterval}
::= {acPMSS7RxMSUTable 1}
-- ****************************************
-- acPMSS7RxMSU TABLE
-- ****************************************
AcPMSS7RxMSUEntry ::= SEQUENCE {
acPMSS7RxMSULink Unsigned32,
acPMSS7RxMSUInterval Unsigned32,
acPMSS7RxMSUVal Counter32,
acPMSS7RxMSUTotal Integer32
}
acPMSS7RxMSULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7RxMSUEntry 1}
acPMSS7RxMSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxMSUEntry 2}
acPMSS7RxMSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxMSUEntry 3}
acPMSS7RxMSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxMSUEntry 4}
-- ****************************************
-- acPMSS7TxLSSU table declaration
-- ****************************************
acPMSS7TxLSSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxLSSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted LSSU's per SS7 link."
::= {acPMSS7Links 3}
-- ****************************************
-- acPMSS7TxLSSU table entry
-- ****************************************
acPMSS7TxLSSUEntry OBJECT-TYPE
SYNTAX AcPMSS7TxLSSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxLSSULink,acPMSS7TxLSSUInterval}
::= {acPMSS7TxLSSUTable 1}
-- ****************************************
-- acPMSS7TxLSSU TABLE
-- ****************************************
AcPMSS7TxLSSUEntry ::= SEQUENCE {
acPMSS7TxLSSULink Unsigned32,
acPMSS7TxLSSUInterval Unsigned32,
acPMSS7TxLSSUVal Counter32,
acPMSS7TxLSSUTotal Integer32
}
acPMSS7TxLSSULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7TxLSSUEntry 1}
acPMSS7TxLSSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxLSSUEntry 2}
acPMSS7TxLSSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxLSSUEntry 3}
acPMSS7TxLSSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxLSSUEntry 4}
-- ****************************************
-- acPMSS7RxLSSU table declaration
-- ****************************************
acPMSS7RxLSSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxLSSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received LSSU's per SS7 link."
::= {acPMSS7Links 4}
-- ****************************************
-- acPMSS7RxLSSU table entry
-- ****************************************
acPMSS7RxLSSUEntry OBJECT-TYPE
SYNTAX AcPMSS7RxLSSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxLSSULink,acPMSS7RxLSSUInterval}
::= {acPMSS7RxLSSUTable 1}
-- ****************************************
-- acPMSS7RxLSSU TABLE
-- ****************************************
AcPMSS7RxLSSUEntry ::= SEQUENCE {
acPMSS7RxLSSULink Unsigned32,
acPMSS7RxLSSUInterval Unsigned32,
acPMSS7RxLSSUVal Counter32,
acPMSS7RxLSSUTotal Integer32
}
acPMSS7RxLSSULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7RxLSSUEntry 1}
acPMSS7RxLSSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxLSSUEntry 2}
acPMSS7RxLSSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxLSSUEntry 3}
acPMSS7RxLSSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxLSSUEntry 4}
-- ****************************************
-- acPMSS7TxFISU table declaration
-- ****************************************
acPMSS7TxFISUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxFISUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted FISU's per SS7 link."
::= {acPMSS7Links 5}
-- ****************************************
-- acPMSS7TxFISU table entry
-- ****************************************
acPMSS7TxFISUEntry OBJECT-TYPE
SYNTAX AcPMSS7TxFISUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxFISULink,acPMSS7TxFISUInterval}
::= {acPMSS7TxFISUTable 1}
-- ****************************************
-- acPMSS7TxFISU TABLE
-- ****************************************
AcPMSS7TxFISUEntry ::= SEQUENCE {
acPMSS7TxFISULink Unsigned32,
acPMSS7TxFISUInterval Unsigned32,
acPMSS7TxFISUVal Counter32,
acPMSS7TxFISUTotal Integer32
}
acPMSS7TxFISULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7TxFISUEntry 1}
acPMSS7TxFISUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxFISUEntry 2}
acPMSS7TxFISUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxFISUEntry 3}
acPMSS7TxFISUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxFISUEntry 4}
-- ****************************************
-- acPMSS7RxFISU table declaration
-- ****************************************
acPMSS7RxFISUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxFISUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received FISU's per SS7 link."
::= {acPMSS7Links 6}
-- ****************************************
-- acPMSS7RxFISU table entry
-- ****************************************
acPMSS7RxFISUEntry OBJECT-TYPE
SYNTAX AcPMSS7RxFISUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxFISULink,acPMSS7RxFISUInterval}
::= {acPMSS7RxFISUTable 1}
-- ****************************************
-- acPMSS7RxFISU TABLE
-- ****************************************
AcPMSS7RxFISUEntry ::= SEQUENCE {
acPMSS7RxFISULink Unsigned32,
acPMSS7RxFISUInterval Unsigned32,
acPMSS7RxFISUVal Counter32,
acPMSS7RxFISUTotal Integer32
}
acPMSS7RxFISULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7RxFISUEntry 1}
acPMSS7RxFISUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxFISUEntry 2}
acPMSS7RxFISUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxFISUEntry 3}
acPMSS7RxFISUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxFISUEntry 4}
-- ****************************************
-- acPMSS7TxSignalUnits table declaration
-- ****************************************
acPMSS7TxSignalUnitsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxSignalUnitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted Signaling units per SS7 link"
::= {acPMSS7Links 7}
-- ****************************************
-- acPMSS7TxSignalUnits table entry
-- ****************************************
acPMSS7TxSignalUnitsEntry OBJECT-TYPE
SYNTAX AcPMSS7TxSignalUnitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxSignalUnitsLink,acPMSS7TxSignalUnitsInterval}
::= {acPMSS7TxSignalUnitsTable 1}
-- ****************************************
-- acPMSS7TxSignalUnits TABLE
-- ****************************************
AcPMSS7TxSignalUnitsEntry ::= SEQUENCE {
acPMSS7TxSignalUnitsLink Unsigned32,
acPMSS7TxSignalUnitsInterval Unsigned32,
acPMSS7TxSignalUnitsVal Counter32,
acPMSS7TxSignalUnitsTotal Integer32
}
acPMSS7TxSignalUnitsLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7TxSignalUnitsEntry 1}
acPMSS7TxSignalUnitsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxSignalUnitsEntry 2}
acPMSS7TxSignalUnitsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxSignalUnitsEntry 3}
acPMSS7TxSignalUnitsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxSignalUnitsEntry 4}
-- ****************************************
-- acPMSS7RxSignalUnits table declaration
-- ****************************************
acPMSS7RxSignalUnitsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxSignalUnitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received Signaling units per SS7 link"
::= {acPMSS7Links 8}
-- ****************************************
-- acPMSS7RxSignalUnits table entry
-- ****************************************
acPMSS7RxSignalUnitsEntry OBJECT-TYPE
SYNTAX AcPMSS7RxSignalUnitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxSignalUnitsLink,acPMSS7RxSignalUnitsInterval}
::= {acPMSS7RxSignalUnitsTable 1}
-- ****************************************
-- acPMSS7RxSignalUnits TABLE
-- ****************************************
AcPMSS7RxSignalUnitsEntry ::= SEQUENCE {
acPMSS7RxSignalUnitsLink Unsigned32,
acPMSS7RxSignalUnitsInterval Unsigned32,
acPMSS7RxSignalUnitsVal Counter32,
acPMSS7RxSignalUnitsTotal Integer32
}
acPMSS7RxSignalUnitsLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7RxSignalUnitsEntry 1}
acPMSS7RxSignalUnitsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxSignalUnitsEntry 2}
acPMSS7RxSignalUnitsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxSignalUnitsEntry 3}
acPMSS7RxSignalUnitsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxSignalUnitsEntry 4}
-- ****************************************
-- acPMSS7TxOctets table declaration
-- ****************************************
acPMSS7TxOctetsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxOctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted Octets per SS7 link - Q.752 3.1"
::= {acPMSS7Links 9}
-- ****************************************
-- acPMSS7TxOctets table entry
-- ****************************************
acPMSS7TxOctetsEntry OBJECT-TYPE
SYNTAX AcPMSS7TxOctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxOctetsLink,acPMSS7TxOctetsInterval}
::= {acPMSS7TxOctetsTable 1}
-- ****************************************
-- acPMSS7TxOctets TABLE
-- ****************************************
AcPMSS7TxOctetsEntry ::= SEQUENCE {
acPMSS7TxOctetsLink Unsigned32,
acPMSS7TxOctetsInterval Unsigned32,
acPMSS7TxOctetsVal Counter32,
acPMSS7TxOctetsTotal Integer32
}
acPMSS7TxOctetsLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7TxOctetsEntry 1}
acPMSS7TxOctetsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxOctetsEntry 2}
acPMSS7TxOctetsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxOctetsEntry 3}
acPMSS7TxOctetsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxOctetsEntry 4}
-- ****************************************
-- acPMSS7RxOctets table declaration
-- ****************************************
acPMSS7RxOctetsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxOctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received Octets per SS7 link - Q.752 3.4"
::= {acPMSS7Links 10}
-- ****************************************
-- acPMSS7RxOctets table entry
-- ****************************************
acPMSS7RxOctetsEntry OBJECT-TYPE
SYNTAX AcPMSS7RxOctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxOctetsLink,acPMSS7RxOctetsInterval}
::= {acPMSS7RxOctetsTable 1}
-- ****************************************
-- acPMSS7RxOctets TABLE
-- ****************************************
AcPMSS7RxOctetsEntry ::= SEQUENCE {
acPMSS7RxOctetsLink Unsigned32,
acPMSS7RxOctetsInterval Unsigned32,
acPMSS7RxOctetsVal Counter32,
acPMSS7RxOctetsTotal Integer32
}
acPMSS7RxOctetsLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7RxOctetsEntry 1}
acPMSS7RxOctetsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxOctetsEntry 2}
acPMSS7RxOctetsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxOctetsEntry 3}
acPMSS7RxOctetsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxOctetsEntry 4}
-- ****************************************
-- acPMSS7MTP2NoAckRx table declaration
-- ****************************************
acPMSS7MTP2NoAckRxTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2NoAckRxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9"
::= {acPMSS7Links 11}
-- ****************************************
-- acPMSS7MTP2NoAckRx table entry
-- ****************************************
acPMSS7MTP2NoAckRxEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2NoAckRxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2NoAckRxLink,acPMSS7MTP2NoAckRxInterval}
::= {acPMSS7MTP2NoAckRxTable 1}
-- ****************************************
-- acPMSS7MTP2NoAckRx TABLE
-- ****************************************
AcPMSS7MTP2NoAckRxEntry ::= SEQUENCE {
acPMSS7MTP2NoAckRxLink Unsigned32,
acPMSS7MTP2NoAckRxInterval Unsigned32,
acPMSS7MTP2NoAckRxVal Counter32,
acPMSS7MTP2NoAckRxTotal Integer32
}
acPMSS7MTP2NoAckRxLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2NoAckRxEntry 1}
acPMSS7MTP2NoAckRxInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2NoAckRxEntry 2}
acPMSS7MTP2NoAckRxVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2NoAckRxEntry 3}
acPMSS7MTP2NoAckRxTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2NoAckRxEntry 4}
-- ****************************************
-- acPMSS7DiscMSU table declaration
-- ****************************************
acPMSS7DiscMSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7DiscMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10"
::= {acPMSS7Links 12}
-- ****************************************
-- acPMSS7DiscMSU table entry
-- ****************************************
acPMSS7DiscMSUEntry OBJECT-TYPE
SYNTAX AcPMSS7DiscMSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7DiscMSULink,acPMSS7DiscMSUInterval}
::= {acPMSS7DiscMSUTable 1}
-- ****************************************
-- acPMSS7DiscMSU TABLE
-- ****************************************
AcPMSS7DiscMSUEntry ::= SEQUENCE {
acPMSS7DiscMSULink Unsigned32,
acPMSS7DiscMSUInterval Unsigned32,
acPMSS7DiscMSUVal Counter32,
acPMSS7DiscMSUTotal Integer32
}
acPMSS7DiscMSULink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7DiscMSUEntry 1}
acPMSS7DiscMSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7DiscMSUEntry 2}
acPMSS7DiscMSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7DiscMSUEntry 3}
acPMSS7DiscMSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7DiscMSUEntry 4}
-- ****************************************
-- acPMSS7InService table declaration
-- ****************************************
acPMSS7InServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7InServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1"
::= {acPMSS7Links 13}
-- ****************************************
-- acPMSS7InService table entry
-- ****************************************
acPMSS7InServiceEntry OBJECT-TYPE
SYNTAX AcPMSS7InServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7InServiceLink,acPMSS7InServiceInterval}
::= {acPMSS7InServiceTable 1}
-- ****************************************
-- acPMSS7InService TABLE
-- ****************************************
AcPMSS7InServiceEntry ::= SEQUENCE {
acPMSS7InServiceLink Unsigned32,
acPMSS7InServiceInterval Unsigned32,
acPMSS7InServiceVal Gauge32,
acPMSS7InServiceTimeAboveHighThreshold Integer32,
acPMSS7InServiceTimeBetweenThresholds Integer32
}
acPMSS7InServiceLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7InServiceEntry 1}
acPMSS7InServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7InServiceEntry 2}
acPMSS7InServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7InServiceEntry 3}
acPMSS7InServiceTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold. In this case - 'In Service'."
::= {acPMSS7InServiceEntry 4}
acPMSS7InServiceTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds. In this case -
not 'In Service'."
::= {acPMSS7InServiceEntry 5}
-- ****************************************
-- acPMSS7OutOfService table declaration
-- ****************************************
acPMSS7OutOfServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7OutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1"
::= {acPMSS7Links 14}
-- ****************************************
-- acPMSS7OutOfService table entry
-- ****************************************
acPMSS7OutOfServiceEntry OBJECT-TYPE
SYNTAX AcPMSS7OutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7OutOfServiceLink,acPMSS7OutOfServiceInterval}
::= {acPMSS7OutOfServiceTable 1}
-- ****************************************
-- acPMSS7OutOfService TABLE
-- ****************************************
AcPMSS7OutOfServiceEntry ::= SEQUENCE {
acPMSS7OutOfServiceLink Unsigned32,
acPMSS7OutOfServiceInterval Unsigned32,
acPMSS7OutOfServiceVal Gauge32,
acPMSS7OutOfServiceTimeAboveHighThreshold Integer32,
acPMSS7OutOfServiceTimeBetweenThresholds Integer32
}
acPMSS7OutOfServiceLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7OutOfServiceEntry 1}
acPMSS7OutOfServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7OutOfServiceEntry 2}
acPMSS7OutOfServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7OutOfServiceEntry 3}
acPMSS7OutOfServiceTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold. In this case - 'Out Of Service'."
::= {acPMSS7OutOfServiceEntry 4}
acPMSS7OutOfServiceTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds. In this case -
not 'Out of Service'."
::= {acPMSS7OutOfServiceEntry 5}
acPMSS7LinkSets OBJECT IDENTIFIER ::= {acPMSS7Data 41}
-- ****************************************
-- acPMSS7SN0LSOutOfService table declaration
-- ****************************************
acPMSS7SN0LSOutOfServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7SN0LSOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
::= {acPMSS7LinkSets 1}
-- ****************************************
-- acPMSS7SN0LSOutOfService table entry
-- ****************************************
acPMSS7SN0LSOutOfServiceEntry OBJECT-TYPE
SYNTAX AcPMSS7SN0LSOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7SN0LSOutOfServiceLinkSet,acPMSS7SN0LSOutOfServiceInterval}
::= {acPMSS7SN0LSOutOfServiceTable 1}
-- ****************************************
-- acPMSS7SN0LSOutOfService TABLE
-- ****************************************
AcPMSS7SN0LSOutOfServiceEntry ::= SEQUENCE {
acPMSS7SN0LSOutOfServiceLinkSet Unsigned32,
acPMSS7SN0LSOutOfServiceInterval Unsigned32,
acPMSS7SN0LSOutOfServiceVal Gauge32,
acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold Integer32,
acPMSS7SN0LSOutOfServiceTimeBetweenThresholds Integer32
}
acPMSS7SN0LSOutOfServiceLinkSet OBJECT-TYPE
SYNTAX Unsigned32 (0..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link Set number.
0 is the first link."
::= {acPMSS7SN0LSOutOfServiceEntry 1}
acPMSS7SN0LSOutOfServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7SN0LSOutOfServiceEntry 2}
acPMSS7SN0LSOutOfServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7SN0LSOutOfServiceEntry 3}
acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold. In this case - 'Out Of Service'."
::= {acPMSS7SN0LSOutOfServiceEntry 4}
acPMSS7SN0LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds. In this case -
not 'Out of Service'."
::= {acPMSS7SN0LSOutOfServiceEntry 5}
-- ****************************************
-- acPMSS7SN1LSOutOfService table declaration
-- ****************************************
acPMSS7SN1LSOutOfServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7SN1LSOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
::= {acPMSS7LinkSets 2}
-- ****************************************
-- acPMSS7SN1LSOutOfService table entry
-- ****************************************
acPMSS7SN1LSOutOfServiceEntry OBJECT-TYPE
SYNTAX AcPMSS7SN1LSOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7SN1LSOutOfServiceLinkSet,acPMSS7SN1LSOutOfServiceInterval}
::= {acPMSS7SN1LSOutOfServiceTable 1}
-- ****************************************
-- acPMSS7SN1LSOutOfService TABLE
-- ****************************************
AcPMSS7SN1LSOutOfServiceEntry ::= SEQUENCE {
acPMSS7SN1LSOutOfServiceLinkSet Unsigned32,
acPMSS7SN1LSOutOfServiceInterval Unsigned32,
acPMSS7SN1LSOutOfServiceVal Gauge32,
acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold Integer32,
acPMSS7SN1LSOutOfServiceTimeBetweenThresholds Integer32
}
acPMSS7SN1LSOutOfServiceLinkSet OBJECT-TYPE
SYNTAX Unsigned32 (0..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link Set number.
0 is the first link."
::= {acPMSS7SN1LSOutOfServiceEntry 1}
acPMSS7SN1LSOutOfServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7SN1LSOutOfServiceEntry 2}
acPMSS7SN1LSOutOfServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7SN1LSOutOfServiceEntry 3}
acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold. In this case - 'Out Of Service'."
::= {acPMSS7SN1LSOutOfServiceEntry 4}
acPMSS7SN1LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds. In this case -
not 'Out of Service'."
::= {acPMSS7SN1LSOutOfServiceEntry 5}
acPMSS7SignalingNodes OBJECT IDENTIFIER ::= {acPMSS7Data 51}
-- ****************************************
-- acPMSS7TxMTP3Octets table declaration
-- ****************************************
acPMSS7TxMTP3OctetsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxMTP3OctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted MTP3 octets per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 1}
-- ****************************************
-- acPMSS7TxMTP3Octets table entry
-- ****************************************
acPMSS7TxMTP3OctetsEntry OBJECT-TYPE
SYNTAX AcPMSS7TxMTP3OctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxMTP3OctetsSN,acPMSS7TxMTP3OctetsInterval}
::= {acPMSS7TxMTP3OctetsTable 1}
-- ****************************************
-- acPMSS7TxMTP3Octets TABLE
-- ****************************************
AcPMSS7TxMTP3OctetsEntry ::= SEQUENCE {
acPMSS7TxMTP3OctetsSN Unsigned32,
acPMSS7TxMTP3OctetsInterval Unsigned32,
acPMSS7TxMTP3OctetsVal Counter32,
acPMSS7TxMTP3OctetsTotal Integer32
}
acPMSS7TxMTP3OctetsSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7TxMTP3OctetsEntry 1}
acPMSS7TxMTP3OctetsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxMTP3OctetsEntry 2}
acPMSS7TxMTP3OctetsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxMTP3OctetsEntry 3}
acPMSS7TxMTP3OctetsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxMTP3OctetsEntry 4}
-- ****************************************
-- acPMSS7RxMTP3Octets table declaration
-- ****************************************
acPMSS7RxMTP3OctetsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxMTP3OctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received MTP3 octets per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 2}
-- ****************************************
-- acPMSS7RxMTP3Octets table entry
-- ****************************************
acPMSS7RxMTP3OctetsEntry OBJECT-TYPE
SYNTAX AcPMSS7RxMTP3OctetsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxMTP3OctetsSN,acPMSS7RxMTP3OctetsInterval}
::= {acPMSS7RxMTP3OctetsTable 1}
-- ****************************************
-- acPMSS7RxMTP3Octets TABLE
-- ****************************************
AcPMSS7RxMTP3OctetsEntry ::= SEQUENCE {
acPMSS7RxMTP3OctetsSN Unsigned32,
acPMSS7RxMTP3OctetsInterval Unsigned32,
acPMSS7RxMTP3OctetsVal Counter32,
acPMSS7RxMTP3OctetsTotal Integer32
}
acPMSS7RxMTP3OctetsSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7RxMTP3OctetsEntry 1}
acPMSS7RxMTP3OctetsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxMTP3OctetsEntry 2}
acPMSS7RxMTP3OctetsVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxMTP3OctetsEntry 3}
acPMSS7RxMTP3OctetsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxMTP3OctetsEntry 4}
-- ****************************************
-- acPMSS7TxMTP3MSU table declaration
-- ****************************************
acPMSS7TxMTP3MSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxMTP3MSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted MTP3 MSU's per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 3}
-- ****************************************
-- acPMSS7TxMTP3MSU table entry
-- ****************************************
acPMSS7TxMTP3MSUEntry OBJECT-TYPE
SYNTAX AcPMSS7TxMTP3MSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxMTP3MSUSN,acPMSS7TxMTP3MSUInterval}
::= {acPMSS7TxMTP3MSUTable 1}
-- ****************************************
-- acPMSS7TxMTP3MSU TABLE
-- ****************************************
AcPMSS7TxMTP3MSUEntry ::= SEQUENCE {
acPMSS7TxMTP3MSUSN Unsigned32,
acPMSS7TxMTP3MSUInterval Unsigned32,
acPMSS7TxMTP3MSUVal Counter32,
acPMSS7TxMTP3MSUTotal Integer32
}
acPMSS7TxMTP3MSUSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7TxMTP3MSUEntry 1}
acPMSS7TxMTP3MSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxMTP3MSUEntry 2}
acPMSS7TxMTP3MSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxMTP3MSUEntry 3}
acPMSS7TxMTP3MSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxMTP3MSUEntry 4}
-- ****************************************
-- acPMSS7RxMTP3MSU table declaration
-- ****************************************
acPMSS7RxMTP3MSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxMTP3MSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received MTP3 MSU's per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 4}
-- ****************************************
-- acPMSS7RxMTP3MSU table entry
-- ****************************************
acPMSS7RxMTP3MSUEntry OBJECT-TYPE
SYNTAX AcPMSS7RxMTP3MSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxMTP3MSUSN,acPMSS7RxMTP3MSUInterval}
::= {acPMSS7RxMTP3MSUTable 1}
-- ****************************************
-- acPMSS7RxMTP3MSU TABLE
-- ****************************************
AcPMSS7RxMTP3MSUEntry ::= SEQUENCE {
acPMSS7RxMTP3MSUSN Unsigned32,
acPMSS7RxMTP3MSUInterval Unsigned32,
acPMSS7RxMTP3MSUVal Counter32,
acPMSS7RxMTP3MSUTotal Integer32
}
acPMSS7RxMTP3MSUSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7RxMTP3MSUEntry 1}
acPMSS7RxMTP3MSUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxMTP3MSUEntry 2}
acPMSS7RxMTP3MSUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxMTP3MSUEntry 3}
acPMSS7RxMTP3MSUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxMTP3MSUEntry 4}
-- ****************************************
-- acPMSS7TxMTP3UPU table declaration
-- ****************************************
acPMSS7TxMTP3UPUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7TxMTP3UPUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 5}
-- ****************************************
-- acPMSS7TxMTP3UPU table entry
-- ****************************************
acPMSS7TxMTP3UPUEntry OBJECT-TYPE
SYNTAX AcPMSS7TxMTP3UPUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7TxMTP3UPUSN,acPMSS7TxMTP3UPUInterval}
::= {acPMSS7TxMTP3UPUTable 1}
-- ****************************************
-- acPMSS7TxMTP3UPU TABLE
-- ****************************************
AcPMSS7TxMTP3UPUEntry ::= SEQUENCE {
acPMSS7TxMTP3UPUSN Unsigned32,
acPMSS7TxMTP3UPUInterval Unsigned32,
acPMSS7TxMTP3UPUVal Counter32,
acPMSS7TxMTP3UPUTotal Integer32
}
acPMSS7TxMTP3UPUSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7TxMTP3UPUEntry 1}
acPMSS7TxMTP3UPUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7TxMTP3UPUEntry 2}
acPMSS7TxMTP3UPUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7TxMTP3UPUEntry 3}
acPMSS7TxMTP3UPUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7TxMTP3UPUEntry 4}
-- ****************************************
-- acPMSS7RxMTP3UPU table declaration
-- ****************************************
acPMSS7RxMTP3UPUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxMTP3UPUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 6}
-- ****************************************
-- acPMSS7RxMTP3UPU table entry
-- ****************************************
acPMSS7RxMTP3UPUEntry OBJECT-TYPE
SYNTAX AcPMSS7RxMTP3UPUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxMTP3UPUSN,acPMSS7RxMTP3UPUInterval}
::= {acPMSS7RxMTP3UPUTable 1}
-- ****************************************
-- acPMSS7RxMTP3UPU TABLE
-- ****************************************
AcPMSS7RxMTP3UPUEntry ::= SEQUENCE {
acPMSS7RxMTP3UPUSN Unsigned32,
acPMSS7RxMTP3UPUInterval Unsigned32,
acPMSS7RxMTP3UPUVal Counter32,
acPMSS7RxMTP3UPUTotal Integer32
}
acPMSS7RxMTP3UPUSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7RxMTP3UPUEntry 1}
acPMSS7RxMTP3UPUInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxMTP3UPUEntry 2}
acPMSS7RxMTP3UPUVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxMTP3UPUEntry 3}
acPMSS7RxMTP3UPUTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxMTP3UPUEntry 4}
-- ****************************************
-- acPMSS7MTP3MSUDiscarded table declaration
-- ****************************************
acPMSS7MTP3MSUDiscardedTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of discarded MTP3 MSU's per SS7 MTP3 node"
::= {acPMSS7SignalingNodes 7}
-- ****************************************
-- acPMSS7MTP3MSUDiscarded table entry
-- ****************************************
acPMSS7MTP3MSUDiscardedEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP3MSUDiscardedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP3MSUDiscardedSN,acPMSS7MTP3MSUDiscardedInterval}
::= {acPMSS7MTP3MSUDiscardedTable 1}
-- ****************************************
-- acPMSS7MTP3MSUDiscarded TABLE
-- ****************************************
AcPMSS7MTP3MSUDiscardedEntry ::= SEQUENCE {
acPMSS7MTP3MSUDiscardedSN Unsigned32,
acPMSS7MTP3MSUDiscardedInterval Unsigned32,
acPMSS7MTP3MSUDiscardedVal Counter32,
acPMSS7MTP3MSUDiscardedTotal Integer32
}
acPMSS7MTP3MSUDiscardedSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7MTP3MSUDiscardedEntry 1}
acPMSS7MTP3MSUDiscardedInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP3MSUDiscardedEntry 2}
acPMSS7MTP3MSUDiscardedVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP3MSUDiscardedEntry 3}
acPMSS7MTP3MSUDiscardedTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP3MSUDiscardedEntry 4}
-- ****************************************
-- acPMSS7MTP3MSUDiscardedRtDataErr table declaration
-- ****************************************
acPMSS7MTP3MSUDiscardedRtDataErrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedRtDataErrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5"
::= {acPMSS7SignalingNodes 8}
-- ****************************************
-- acPMSS7MTP3MSUDiscardedRtDataErr table entry
-- ****************************************
acPMSS7MTP3MSUDiscardedRtDataErrEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP3MSUDiscardedRtDataErrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP3MSUDiscardedRtDataErrSN,acPMSS7MTP3MSUDiscardedRtDataErrInterval}
::= {acPMSS7MTP3MSUDiscardedRtDataErrTable 1}
-- ****************************************
-- acPMSS7MTP3MSUDiscardedRtDataErr TABLE
-- ****************************************
AcPMSS7MTP3MSUDiscardedRtDataErrEntry ::= SEQUENCE {
acPMSS7MTP3MSUDiscardedRtDataErrSN Unsigned32,
acPMSS7MTP3MSUDiscardedRtDataErrInterval Unsigned32,
acPMSS7MTP3MSUDiscardedRtDataErrVal Counter32,
acPMSS7MTP3MSUDiscardedRtDataErrTotal Integer32
}
acPMSS7MTP3MSUDiscardedRtDataErrSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 1}
acPMSS7MTP3MSUDiscardedRtDataErrInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 2}
acPMSS7MTP3MSUDiscardedRtDataErrVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 3}
acPMSS7MTP3MSUDiscardedRtDataErrTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 4}
-- ****************************************
-- acPMSS7RxMTP3TFCMsg table declaration
-- ****************************************
acPMSS7RxMTP3TFCMsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7RxMTP3TFCMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP3 TFC messages received per SS7 MTP3 node "
::= {acPMSS7SignalingNodes 9}
-- ****************************************
-- acPMSS7RxMTP3TFCMsg table entry
-- ****************************************
acPMSS7RxMTP3TFCMsgEntry OBJECT-TYPE
SYNTAX AcPMSS7RxMTP3TFCMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7RxMTP3TFCMsgSN,acPMSS7RxMTP3TFCMsgInterval}
::= {acPMSS7RxMTP3TFCMsgTable 1}
-- ****************************************
-- acPMSS7RxMTP3TFCMsg TABLE
-- ****************************************
AcPMSS7RxMTP3TFCMsgEntry ::= SEQUENCE {
acPMSS7RxMTP3TFCMsgSN Unsigned32,
acPMSS7RxMTP3TFCMsgInterval Unsigned32,
acPMSS7RxMTP3TFCMsgVal Counter32,
acPMSS7RxMTP3TFCMsgTotal Integer32
}
acPMSS7RxMTP3TFCMsgSN OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SN number.
0 is the first SN."
::= {acPMSS7RxMTP3TFCMsgEntry 1}
acPMSS7RxMTP3TFCMsgInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7RxMTP3TFCMsgEntry 2}
acPMSS7RxMTP3TFCMsgVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7RxMTP3TFCMsgEntry 3}
acPMSS7RxMTP3TFCMsgTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7RxMTP3TFCMsgEntry 4}
acPMSS7MPT2Timers OBJECT IDENTIFIER ::= {acPMSS7Data 61}
-- ****************************************
-- acPMSS7MTP2T1Expiry table declaration
-- ****************************************
acPMSS7MTP2T1ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T1ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T1 expiry per SS7 link"
::= {acPMSS7MPT2Timers 1}
-- ****************************************
-- acPMSS7MTP2T1Expiry table entry
-- ****************************************
acPMSS7MTP2T1ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T1ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T1ExpiryLink,acPMSS7MTP2T1ExpiryInterval}
::= {acPMSS7MTP2T1ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T1Expiry TABLE
-- ****************************************
AcPMSS7MTP2T1ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T1ExpiryLink Unsigned32,
acPMSS7MTP2T1ExpiryInterval Unsigned32,
acPMSS7MTP2T1ExpiryVal Counter32,
acPMSS7MTP2T1ExpiryTotal Integer32
}
acPMSS7MTP2T1ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T1ExpiryEntry 1}
acPMSS7MTP2T1ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T1ExpiryEntry 2}
acPMSS7MTP2T1ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T1ExpiryEntry 3}
acPMSS7MTP2T1ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T1ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T2Expiry table declaration
-- ****************************************
acPMSS7MTP2T2ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T2ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T2 expiry per SS7 link"
::= {acPMSS7MPT2Timers 2}
-- ****************************************
-- acPMSS7MTP2T2Expiry table entry
-- ****************************************
acPMSS7MTP2T2ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T2ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T2ExpiryLink,acPMSS7MTP2T2ExpiryInterval}
::= {acPMSS7MTP2T2ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T2Expiry TABLE
-- ****************************************
AcPMSS7MTP2T2ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T2ExpiryLink Unsigned32,
acPMSS7MTP2T2ExpiryInterval Unsigned32,
acPMSS7MTP2T2ExpiryVal Counter32,
acPMSS7MTP2T2ExpiryTotal Integer32
}
acPMSS7MTP2T2ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T2ExpiryEntry 1}
acPMSS7MTP2T2ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T2ExpiryEntry 2}
acPMSS7MTP2T2ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T2ExpiryEntry 3}
acPMSS7MTP2T2ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T2ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T3Expiry table declaration
-- ****************************************
acPMSS7MTP2T3ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T3ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T3 expiry per SS7 link"
::= {acPMSS7MPT2Timers 3}
-- ****************************************
-- acPMSS7MTP2T3Expiry table entry
-- ****************************************
acPMSS7MTP2T3ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T3ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T3ExpiryLink,acPMSS7MTP2T3ExpiryInterval}
::= {acPMSS7MTP2T3ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T3Expiry TABLE
-- ****************************************
AcPMSS7MTP2T3ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T3ExpiryLink Unsigned32,
acPMSS7MTP2T3ExpiryInterval Unsigned32,
acPMSS7MTP2T3ExpiryVal Counter32,
acPMSS7MTP2T3ExpiryTotal Integer32
}
acPMSS7MTP2T3ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T3ExpiryEntry 1}
acPMSS7MTP2T3ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T3ExpiryEntry 2}
acPMSS7MTP2T3ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T3ExpiryEntry 3}
acPMSS7MTP2T3ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T3ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T4Expiry table declaration
-- ****************************************
acPMSS7MTP2T4ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T4ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T4 expiry per SS7 link"
::= {acPMSS7MPT2Timers 4}
-- ****************************************
-- acPMSS7MTP2T4Expiry table entry
-- ****************************************
acPMSS7MTP2T4ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T4ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T4ExpiryLink,acPMSS7MTP2T4ExpiryInterval}
::= {acPMSS7MTP2T4ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T4Expiry TABLE
-- ****************************************
AcPMSS7MTP2T4ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T4ExpiryLink Unsigned32,
acPMSS7MTP2T4ExpiryInterval Unsigned32,
acPMSS7MTP2T4ExpiryVal Counter32,
acPMSS7MTP2T4ExpiryTotal Integer32
}
acPMSS7MTP2T4ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T4ExpiryEntry 1}
acPMSS7MTP2T4ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T4ExpiryEntry 2}
acPMSS7MTP2T4ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T4ExpiryEntry 3}
acPMSS7MTP2T4ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T4ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T5Expiry table declaration
-- ****************************************
acPMSS7MTP2T5ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T5ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T5 expiry per SS7 link"
::= {acPMSS7MPT2Timers 5}
-- ****************************************
-- acPMSS7MTP2T5Expiry table entry
-- ****************************************
acPMSS7MTP2T5ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T5ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T5ExpiryLink,acPMSS7MTP2T5ExpiryInterval}
::= {acPMSS7MTP2T5ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T5Expiry TABLE
-- ****************************************
AcPMSS7MTP2T5ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T5ExpiryLink Unsigned32,
acPMSS7MTP2T5ExpiryInterval Unsigned32,
acPMSS7MTP2T5ExpiryVal Counter32,
acPMSS7MTP2T5ExpiryTotal Integer32
}
acPMSS7MTP2T5ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T5ExpiryEntry 1}
acPMSS7MTP2T5ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T5ExpiryEntry 2}
acPMSS7MTP2T5ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T5ExpiryEntry 3}
acPMSS7MTP2T5ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T5ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T6Expiry table declaration
-- ****************************************
acPMSS7MTP2T6ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T6ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T6 expiry per SS7 link"
::= {acPMSS7MPT2Timers 6}
-- ****************************************
-- acPMSS7MTP2T6Expiry table entry
-- ****************************************
acPMSS7MTP2T6ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T6ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T6ExpiryLink,acPMSS7MTP2T6ExpiryInterval}
::= {acPMSS7MTP2T6ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T6Expiry TABLE
-- ****************************************
AcPMSS7MTP2T6ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T6ExpiryLink Unsigned32,
acPMSS7MTP2T6ExpiryInterval Unsigned32,
acPMSS7MTP2T6ExpiryVal Counter32,
acPMSS7MTP2T6ExpiryTotal Integer32
}
acPMSS7MTP2T6ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T6ExpiryEntry 1}
acPMSS7MTP2T6ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T6ExpiryEntry 2}
acPMSS7MTP2T6ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T6ExpiryEntry 3}
acPMSS7MTP2T6ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T6ExpiryEntry 4}
-- ****************************************
-- acPMSS7MTP2T7Expiry table declaration
-- ****************************************
acPMSS7MTP2T7ExpiryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMSS7MTP2T7ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of MTP2 T7 expiry per SS7 link"
::= {acPMSS7MPT2Timers 7}
-- ****************************************
-- acPMSS7MTP2T7Expiry table entry
-- ****************************************
acPMSS7MTP2T7ExpiryEntry OBJECT-TYPE
SYNTAX AcPMSS7MTP2T7ExpiryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMSS7MTP2T7ExpiryLink,acPMSS7MTP2T7ExpiryInterval}
::= {acPMSS7MTP2T7ExpiryTable 1}
-- ****************************************
-- acPMSS7MTP2T7Expiry TABLE
-- ****************************************
AcPMSS7MTP2T7ExpiryEntry ::= SEQUENCE {
acPMSS7MTP2T7ExpiryLink Unsigned32,
acPMSS7MTP2T7ExpiryInterval Unsigned32,
acPMSS7MTP2T7ExpiryVal Counter32,
acPMSS7MTP2T7ExpiryTotal Integer32
}
acPMSS7MTP2T7ExpiryLink OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link number.
0 is the first link."
::= {acPMSS7MTP2T7ExpiryEntry 1}
acPMSS7MTP2T7ExpiryInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMSS7MTP2T7ExpiryEntry 2}
acPMSS7MTP2T7ExpiryVal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMSS7MTP2T7ExpiryEntry 3}
acPMSS7MTP2T7ExpiryTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMSS7MTP2T7ExpiryEntry 4}
END