4795 lines
128 KiB
Plaintext
4795 lines
128 KiB
Plaintext
|
|
AC-SS7-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
|
|
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY FROM SNMPv2-SMI
|
|
TAddress,
|
|
DisplayString,
|
|
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
IpAddress FROM RFC1155-SMI
|
|
Unsigned32,
|
|
Integer32,
|
|
enterprises FROM SNMPv2-SMI
|
|
RowStatus FROM SNMPv2-TC
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
audioCodes,
|
|
acRegistrations,
|
|
acGeneric,
|
|
acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB;
|
|
|
|
|
|
acSS7 MODULE-IDENTITY
|
|
LAST-UPDATED "201207260528Z" --Thursday, July 26 2012
|
|
ORGANIZATION "AudioCodes Ltd"
|
|
CONTACT-INFO
|
|
"Postal: Support
|
|
AudioCodes LTD
|
|
1 Hayarden Street
|
|
Airport City
|
|
Lod, ISRAEL 70151
|
|
Tel: 972-3-9764000
|
|
Fax: 972-3-9764040
|
|
Email: support@audiocodes.com
|
|
Web: www.audiocodes.com"
|
|
|
|
DESCRIPTION
|
|
""
|
|
|
|
|
|
|
|
::= {acBoardMibs 12}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
acSS7Configuration OBJECT IDENTIFIER ::= {acSS7 1}
|
|
|
|
|
|
acSS7MTP2 OBJECT IDENTIFIER ::= {acSS7Configuration 1}
|
|
|
|
|
|
acSS7MTP2M3bSlDiscardCongThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter concerns feature that prevents uncontrolled increase
|
|
of the MTP2 Transmit queue when the upper levels ignores
|
|
the usual flow control mechanism.
|
|
Any new SL_TX_MSU_RQ is discarded when the number of msu queued
|
|
on the TB or RTB overtakes the threshold.
|
|
Value 0, means that this feature is not activated.
|
|
Access: Offline.
|
|
AC INI-Param: SS7M3bSlDiscardCongThreshold"
|
|
::= {acSS7MTP2 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7MTP2Attrib table declaration
|
|
-- ****************************************
|
|
acSS7MTP2AttribTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7MTP2AttribEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7MTP2 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7MTP2Attrib table entry
|
|
-- ****************************************
|
|
acSS7MTP2AttribEntry OBJECT-TYPE
|
|
SYNTAX AcSS7MTP2AttribEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7MTP2AttribIndex}
|
|
::= {acSS7MTP2AttribTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7MTP2Attrib TABLE
|
|
-- ****************************************
|
|
AcSS7MTP2AttribEntry ::= SEQUENCE {
|
|
acSS7MTP2AttribIndex Unsigned32,
|
|
acSS7MTP2AttribIsUsed INTEGER,
|
|
acSS7MTP2AttribLinkRate SnmpAdminString,
|
|
acSS7MTP2AttribErrorCorectionMethod SnmpAdminString,
|
|
acSS7MTP2AttribIacCp Unsigned32,
|
|
acSS7MTP2AttribSUERMThreshold Unsigned32,
|
|
acSS7MTP2AttribAERMNormalThreshold Unsigned32,
|
|
acSS7MTP2AttribAERMEmerglThreshold Unsigned32,
|
|
acSS7MTP2AttribSUERMSigUnitDThreshold Unsigned32,
|
|
acSS7MTP2AttribOctetCounting Unsigned32,
|
|
acSS7MTP2AttribTimerT1 Unsigned32,
|
|
acSS7MTP2AttribTimerT2 Unsigned32,
|
|
acSS7MTP2AttribTimerT3 Unsigned32,
|
|
acSS7MTP2AttribTimerT4Normal Unsigned32,
|
|
acSS7MTP2AttribTimerT4Emerg Unsigned32,
|
|
acSS7MTP2AttribTimerT5 Unsigned32,
|
|
acSS7MTP2AttribTimerT6 Unsigned32,
|
|
acSS7MTP2AttribTimerT7 Unsigned32,
|
|
acSS7MTP2AttribLSSULength Unsigned32,
|
|
acSS7MTP2AttribPcrN2 Unsigned32,
|
|
acSS7MTP2AttribRowStatus RowStatus
|
|
}
|
|
|
|
|
|
|
|
acSS7MTP2AttribIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..3)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index Field for line.
|
|
AC INI-Param: SS7Mtp2Parms_Index"
|
|
::= {acSS7MTP2AttribEntry 1}
|
|
|
|
|
|
|
|
acSS7MTP2AttribIsUsed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the row used by alink.
|
|
If it is the entrow will be read.
|
|
AC INI-Param: N/A"
|
|
::= {acSS7MTP2AttribEntry 2}
|
|
|
|
|
|
|
|
acSS7MTP2AttribLinkRate OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..1))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 SLI Link Rate.
|
|
Choose either:
|
|
A = 64 kbps
|
|
D = 56 kbps
|
|
0 = 64 kbps.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_LinkRate"
|
|
::= {acSS7MTP2AttribEntry 3}
|
|
|
|
|
|
|
|
acSS7MTP2AttribErrorCorectionMethod OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..1))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SLI error correction method.
|
|
B = Basic
|
|
P = PCR (Preventive Cyclic Retransmission).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod"
|
|
::= {acSS7MTP2AttribEntry 4}
|
|
|
|
|
|
|
|
acSS7MTP2AttribIacCp OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the number of aborted proving attempts before sending
|
|
an out-of-service to MTP-3.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_IacCp"
|
|
::= {acSS7MTP2AttribEntry 5}
|
|
|
|
|
|
|
|
acSS7MTP2AttribSUERMThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..256)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_SuermT"
|
|
::= {acSS7MTP2AttribEntry 6}
|
|
|
|
|
|
|
|
acSS7MTP2AttribAERMNormalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..20)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Normal AERM (alignment error rate monitor) threshold [0 to 20].
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_AermTin"
|
|
::= {acSS7MTP2AttribEntry 7}
|
|
|
|
|
|
|
|
acSS7MTP2AttribAERMEmerglThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emergency AERM (alignment error rate monitor) threshold [0 to
|
|
10].
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_AermTie"
|
|
::= {acSS7MTP2AttribEntry 8}
|
|
|
|
|
|
|
|
acSS7MTP2AttribSUERMSigUnitDThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..256)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 Signal Unit error rate monitor D threshold.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_SuermSuD"
|
|
::= {acSS7MTP2AttribEntry 9}
|
|
|
|
|
|
|
|
acSS7MTP2AttribOctetCounting OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..256)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 Octet received while the OCTET is in counting
|
|
mode (# of Octets received - N Octets - while in Octet
|
|
counting mode).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_OctetCounting"
|
|
::= {acSS7MTP2AttribEntry 10}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 T1 alignment ready timer (in msecs).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T1"
|
|
::= {acSS7MTP2AttribEntry 11}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..200000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 T2 unaligned timer (in msecs).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T2"
|
|
::= {acSS7MTP2AttribEntry 12}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT3 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..20000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 T3 timer aligned.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T3"
|
|
::= {acSS7MTP2AttribEntry 13}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT4Normal OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 T4n Normal proving period timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T4n"
|
|
::= {acSS7MTP2AttribEntry 14}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT4Emerg OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..5000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 T4e Emergency proving period timer (msec).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T4e"
|
|
::= {acSS7MTP2AttribEntry 15}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT5 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2400)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 Sending SIB timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T5"
|
|
::= {acSS7MTP2AttribEntry 16}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT6 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 Remote Congestion timer (in msec).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T6"
|
|
::= {acSS7MTP2AttribEntry 17}
|
|
|
|
|
|
|
|
acSS7MTP2AttribTimerT7 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..5000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 excessive delay of the ack timer (in msec).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_T7"
|
|
::= {acSS7MTP2AttribEntry 18}
|
|
|
|
|
|
|
|
acSS7MTP2AttribLSSULength OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..2)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_LssuLength"
|
|
::= {acSS7MTP2AttribEntry 19}
|
|
|
|
|
|
|
|
acSS7MTP2AttribPcrN2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..512)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to define Preventive Cyclic Retransmission
|
|
- the number of message signal unit octets available for
|
|
retransmission (ITU-T Q703 6.4 - Forced retransmission).
|
|
Access: Online.
|
|
AC INI-Param: SS7Mtp2Parms_PcrN2"
|
|
::= {acSS7MTP2AttribEntry 20}
|
|
|
|
|
|
|
|
acSS7MTP2AttribRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: N/A"
|
|
::= {acSS7MTP2AttribEntry 21}
|
|
|
|
|
|
|
|
acSS7Timers OBJECT IDENTIFIER ::= {acSS7Configuration 2}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNodeTimers table declaration
|
|
-- ****************************************
|
|
acSS7SignalingNodeTimersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7SignalingNodeTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Timers 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNodeTimers table entry
|
|
-- ****************************************
|
|
acSS7SignalingNodeTimersEntry OBJECT-TYPE
|
|
SYNTAX AcSS7SignalingNodeTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7SignalingNodeTimersIndex}
|
|
::= {acSS7SignalingNodeTimersTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNodeTimers TABLE
|
|
-- ****************************************
|
|
AcSS7SignalingNodeTimersEntry ::= SEQUENCE {
|
|
acSS7SignalingNodeTimersIndex Unsigned32,
|
|
acSS7SignalingNodeTimersIsUsed INTEGER,
|
|
acSS7SignalingNodeTimersAction INTEGER,
|
|
acSS7SignalingNodeTimersActionResult INTEGER,
|
|
acSS7SignalingNodeTimersName SnmpAdminString,
|
|
acSS7SignalingNodeTimersT6 Unsigned32,
|
|
acSS7SignalingNodeTimersT8 Unsigned32,
|
|
acSS7SignalingNodeTimersT10 Unsigned32,
|
|
acSS7SignalingNodeTimersT11 Unsigned32,
|
|
acSS7SignalingNodeTimersT15 Unsigned32,
|
|
acSS7SignalingNodeTimersT16 Unsigned32,
|
|
acSS7SignalingNodeTimersT18ITU Unsigned32,
|
|
acSS7SignalingNodeTimersT19ITU Unsigned32,
|
|
acSS7SignalingNodeTimersT20ITU Unsigned32,
|
|
acSS7SignalingNodeTimersT21ITU Unsigned32,
|
|
acSS7SignalingNodeTimersT24ITU Unsigned32,
|
|
acSS7SignalingNodeTimersT22ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT23ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT24ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT25ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT26ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT27ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT28ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT29ANSI Unsigned32,
|
|
acSS7SignalingNodeTimersT30ANSI Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index Field for line.
|
|
AC INI-Param: SS7_SNTIMERS_INDEX"
|
|
::= {acSS7SignalingNodeTimersEntry 1}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersIsUsed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7SignalingNodeTimersEntry 2}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_SNTIMERS_ACTION"
|
|
::= {acSS7SignalingNodeTimersEntry 3}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_SNTIMERS_ACTION_RESULT"
|
|
::= {acSS7SignalingNodeTimersEntry 4}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for SN timer-set.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_NAME"
|
|
::= {acSS7SignalingNodeTimersEntry 5}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT6 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay to avoid message mis-sequencing on controlled rerouting.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T6"
|
|
::= {acSS7SignalingNodeTimersEntry 6}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT8 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transfer prohibited inhibition timer (transient solution).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T8"
|
|
::= {acSS7SignalingNodeTimersEntry 7}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT10 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting to repeat signalling route set test message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T10"
|
|
::= {acSS7SignalingNodeTimersEntry 8}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT11 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transfer restricted timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T11"
|
|
::= {acSS7SignalingNodeTimersEntry 9}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT15 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting to start signalling route set congestion test.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T15"
|
|
::= {acSS7SignalingNodeTimersEntry 10}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT16 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for route set congestion status update.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T16"
|
|
::= {acSS7SignalingNodeTimersEntry 11}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT18ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer within a signalling point whose MTP restarts for supervising
|
|
link and link set activation as well as the receipt of
|
|
routing information.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T18_ITU"
|
|
::= {acSS7SignalingNodeTimersEntry 12}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT19ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Supervision timer during MTP restart to avoid possible ping-pong
|
|
of TFP, TFR and TRA messages.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T19_ITU"
|
|
::= {acSS7SignalingNodeTimersEntry 13}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT20ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overall MTP restart timer at the signalling point whose MTP
|
|
restarts.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T20_ITU"
|
|
::= {acSS7SignalingNodeTimersEntry 14}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT21ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overall MTP restart timer at a signalling point adjacent to
|
|
one whose MTP restarts.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T21_ITU"
|
|
::= {acSS7SignalingNodeTimersEntry 15}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT24ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stabilising timer after removal of local processor outage, used
|
|
in LPO latching to RPO (national option).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T24_ITU"
|
|
::= {acSS7SignalingNodeTimersEntry 16}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT22ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at restarting SP waiting for signalling links to bacome
|
|
available.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T22_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 17}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT23ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at restarting SP, started after T22, waiting to receive
|
|
all traffic restart allowed messages.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T23_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 18}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT24ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at restarting SP with transfer function, started after
|
|
T23, waiting to broadcast all traffic restart allowed messages.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T24_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 19}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT25ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at SP adjacent to restarting SP waiting for traffic restart
|
|
allowed message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T25_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 20}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT26ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at restarting SP waiting to repeat traffic restart waiting
|
|
message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T26_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 21}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT27ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to define the minimum duration of unavailability
|
|
for a full restart.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T27_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 22}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT28ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer at SP adjacent to restarting SP waiting for traffic restart
|
|
waiting message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T28_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 23}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT29ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer started when TRA sent in response to unexpected TRA or
|
|
TRW.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T29_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 24}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersT30ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer to limit sending of TFPs and TFRs in response to unexpected
|
|
TRA or TRW.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SNTIMERS_T30_ANSI"
|
|
::= {acSS7SignalingNodeTimersEntry 25}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetTimers table declaration
|
|
-- ****************************************
|
|
acSS7LinkSetTimersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkSetTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Timers 22}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetTimers table entry
|
|
-- ****************************************
|
|
acSS7LinkSetTimersEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkSetTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkSetTimersIndex}
|
|
::= {acSS7LinkSetTimersTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetTimers TABLE
|
|
-- ****************************************
|
|
AcSS7LinkSetTimersEntry ::= SEQUENCE {
|
|
acSS7LinkSetTimersIndex Unsigned32,
|
|
acSS7LinkSetTimersIsUsed INTEGER,
|
|
acSS7LinkSetTimersAction INTEGER,
|
|
acSS7LinkSetTimersActionResult INTEGER,
|
|
acSS7LinkSetTimersName SnmpAdminString,
|
|
acSS7LinkSetTimersT1SLT Unsigned32,
|
|
acSS7LinkSetTimersT2SLT Unsigned32,
|
|
acSS7LinkSetTimersT1 Unsigned32,
|
|
acSS7LinkSetTimersT2 Unsigned32,
|
|
acSS7LinkSetTimersT3 Unsigned32,
|
|
acSS7LinkSetTimersT4 Unsigned32,
|
|
acSS7LinkSetTimersT5 Unsigned32,
|
|
acSS7LinkSetTimersT7 Unsigned32,
|
|
acSS7LinkSetTimersT12 Unsigned32,
|
|
acSS7LinkSetTimersT13 Unsigned32,
|
|
acSS7LinkSetTimersT14 Unsigned32,
|
|
acSS7LinkSetTimersT17 Unsigned32,
|
|
acSS7LinkSetTimersT20ANSI Unsigned32,
|
|
acSS7LinkSetTimersT21ANSI Unsigned32,
|
|
acSS7LinkSetTimersT22ITU Unsigned32,
|
|
acSS7LinkSetTimersT23ITU Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index Field for line.
|
|
AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX"
|
|
::= {acSS7LinkSetTimersEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersIsUsed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7LinkSetTimersEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_LKSETTIMERS_ACTION"
|
|
::= {acSS7LinkSetTimersEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT"
|
|
::= {acSS7LinkSetTimersEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for Linkset timer-set.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_NAME"
|
|
::= {acSS7LinkSetTimersEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT1SLT OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Supervision timer for signalling link test acknowledgement message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T1SLT"
|
|
::= {acSS7LinkSetTimersEntry 6}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT2SLT OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval timer for sending signalling link test messages.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T2SLT"
|
|
::= {acSS7LinkSetTimersEntry 7}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay to avoid message mis-sequencing on changeover.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T1"
|
|
::= {acSS7LinkSetTimersEntry 8}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for changeover acknowledgement.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T2"
|
|
::= {acSS7LinkSetTimersEntry 9}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT3 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time controlled diversion-delay to avoid mis-sequencing on changeback.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T3"
|
|
::= {acSS7LinkSetTimersEntry 10}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT4 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for changeback acknowledgement (first attempt).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T4"
|
|
::= {acSS7LinkSetTimersEntry 11}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT5 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for changeback acknowledgement (second attempt).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T5"
|
|
::= {acSS7LinkSetTimersEntry 12}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT7 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for signalling data link connection acknowledgement.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T7"
|
|
::= {acSS7LinkSetTimersEntry 13}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT12 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for uninhibit acknowledgement.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T12"
|
|
::= {acSS7LinkSetTimersEntry 14}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT13 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for force uninhibit.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T13"
|
|
::= {acSS7LinkSetTimersEntry 15}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT14 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting for inhibition acknowledgement.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T14"
|
|
::= {acSS7LinkSetTimersEntry 16}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT17 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay to avoid oscillation of initial alignment failure and
|
|
link restart.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T17"
|
|
::= {acSS7LinkSetTimersEntry 17}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT20ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local inhibit test timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T20_ANSI"
|
|
::= {acSS7LinkSetTimersEntry 18}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT21ANSI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote inhibit test timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T21_ANSI"
|
|
::= {acSS7LinkSetTimersEntry 19}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT22ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local inhibit test timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T22_ITU"
|
|
::= {acSS7LinkSetTimersEntry 20}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersT23ITU OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote inhibit test timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LKSETTIMERS_T23_ITU"
|
|
::= {acSS7LinkSetTimersEntry 21}
|
|
|
|
|
|
|
|
acSS7Links OBJECT IDENTIFIER ::= {acSS7Configuration 3}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkCommon table declaration
|
|
-- ****************************************
|
|
acSS7LinkCommonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkCommonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Links 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkCommon table entry
|
|
-- ****************************************
|
|
acSS7LinkCommonEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkCommonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkCommonIndex}
|
|
::= {acSS7LinkCommonTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkCommon TABLE
|
|
-- ****************************************
|
|
AcSS7LinkCommonEntry ::= SEQUENCE {
|
|
acSS7LinkCommonIndex Unsigned32,
|
|
acSS7LinkCommonRowStatus RowStatus,
|
|
acSS7LinkCommonAction INTEGER,
|
|
acSS7LinkCommonActionResult INTEGER,
|
|
acSS7LinkCommonName SnmpAdminString,
|
|
acSS7LinkCommonAdminState INTEGER,
|
|
acSS7LinkCommonOperState INTEGER,
|
|
acSS7LinkCommonTraceLevel INTEGER,
|
|
acSS7LinkCommonL2TypeSelector INTEGER,
|
|
acSS7LinkCommonL3TypeSelector INTEGER,
|
|
acSS7LinkCommonVariant INTEGER,
|
|
acSS7LinkCommonMtcBusy INTEGER,
|
|
acSS7LinkCommonRdcyBoardNum INTEGER,
|
|
acSS7LinkCommonMonSuFilterRequest INTEGER
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkCommonIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index Field for line.
|
|
AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD"
|
|
::= {acSS7LinkCommonEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkCommonRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_LINK_ROWSTATUS"
|
|
::= {acSS7LinkCommonEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkCommonAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
offLine(1)
|
|
,
|
|
inService(2)
|
|
,
|
|
activate(3)
|
|
,
|
|
deActivate(4)
|
|
,
|
|
inhibit(5)
|
|
,
|
|
unInhibit(6)
|
|
,
|
|
lpo(7)
|
|
,
|
|
lpr(8)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_LINK_ACTION"
|
|
::= {acSS7LinkCommonEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkCommonActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_LINK_ACTION_RESULT"
|
|
::= {acSS7LinkCommonEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkCommonName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for Link paramaters.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_NAME"
|
|
::= {acSS7LinkCommonEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkCommonAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state of singnalling link.
|
|
AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE"
|
|
::= {acSS7LinkCommonEntry 6}
|
|
|
|
|
|
|
|
acSS7LinkCommonOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational state of singnalling link.
|
|
AC INI-Param: SS7_LINK_OPERATIONAL_STATE"
|
|
::= {acSS7LinkCommonEntry 7}
|
|
|
|
|
|
|
|
acSS7LinkCommonTraceLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
traceLevel0(0)
|
|
,
|
|
traceLevel1(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trace level of singnalling link (level 2).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TRACE_LEVEL"
|
|
::= {acSS7LinkCommonEntry 8}
|
|
|
|
|
|
|
|
acSS7LinkCommonL2TypeSelector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nonetype-L2(0)
|
|
,
|
|
mtp2(1)
|
|
,
|
|
m2ua-mgc(2)
|
|
,
|
|
ss7monitoring(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link layer 2 type - defines level 2 media of signaling link.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_L2_TYPE"
|
|
::= {acSS7LinkCommonEntry 9}
|
|
|
|
|
|
|
|
acSS7LinkCommonL3TypeSelector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nonetype-L3(0)
|
|
,
|
|
m2ua-sg(1)
|
|
,
|
|
mtp3(2)
|
|
,
|
|
mtp2-tunneling(3)
|
|
,
|
|
mtp2OverIP(4)
|
|
,
|
|
ss7monitoring(5)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link high layer type - defines level 3 or L2 high layer of signalling
|
|
link.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_L3_TYPE"
|
|
::= {acSS7LinkCommonEntry 10}
|
|
|
|
|
|
|
|
acSS7LinkCommonVariant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
itu(1)
|
|
,
|
|
ansi(2)
|
|
,
|
|
china(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Variant (layer 2) of singnalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_LAYER2_VARIANT"
|
|
::= {acSS7LinkCommonEntry 11}
|
|
|
|
|
|
|
|
acSS7LinkCommonMtcBusy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link local busy indicator - if set, indicates link is busy due
|
|
to local mtc action.
|
|
AC INI-Param: SS7_LINK_MTC_BUSY"
|
|
::= {acSS7LinkCommonEntry 12}
|
|
|
|
|
|
|
|
acSS7LinkCommonRdcyBoardNum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rdcyBoardNum0(0)
|
|
,
|
|
rdcyBoardNum1(1)
|
|
,
|
|
rdcyBoardNum2(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Board number in which the link is physically connected.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_RDCY_BOARD"
|
|
::= {acSS7LinkCommonEntry 13}
|
|
|
|
|
|
|
|
acSS7LinkCommonMonSuFilterRequest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
filterAll(0)
|
|
,
|
|
filterLSSUandFISU(1)
|
|
,
|
|
filterFISU(2)
|
|
,
|
|
noFilter(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SS7 Monitoring link SU filter- Defines the type of SU message
|
|
to filter. 0: Filter all types of SU messages
|
|
1: Filter LSSU and FISU messages
|
|
2: Filter only FISU messages
|
|
3: Do not filter any message.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_MON_SU_FILTER"
|
|
::= {acSS7LinkCommonEntry 14}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTDM table declaration
|
|
-- ****************************************
|
|
acSS7LinkTDMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkTDMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Links 22}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTDM table entry
|
|
-- ****************************************
|
|
acSS7LinkTDMEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkTDMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkCommonIndex}
|
|
::= {acSS7LinkTDMTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTDM TABLE
|
|
-- ****************************************
|
|
AcSS7LinkTDMEntry ::= SEQUENCE {
|
|
acSS7LinkTDMTrunkNumber Integer32,
|
|
acSS7LinkTDMTimeSlotNumber Unsigned32,
|
|
acSS7LinkTDMInhibit INTEGER,
|
|
acSS7LinkTDMMtp2Atts INTEGER,
|
|
acSS7LinkTDMCongestionLowMark Unsigned32,
|
|
acSS7LinkTDMCongestionHighMark Unsigned32,
|
|
acSS7LinkTDMBlock INTEGER
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkTDMTrunkNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..84)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trunk number of singnalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TRUNK_NUMBER"
|
|
::= {acSS7LinkTDMEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkTDMTimeSlotNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time-Slot number of singnalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TIMESLOT_NUMBER"
|
|
::= {acSS7LinkTDMEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkTDMInhibit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unInhibited(0)
|
|
,
|
|
inhibited(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link inhibit indicator - if set, indicates link is inhibited..
|
|
AC INI-Param: SS7_LINK_INHIBITION"
|
|
::= {acSS7LinkTDMEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkTDMMtp2Atts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mtp2Atts0(0)
|
|
,
|
|
mtp2Atts1(1)
|
|
,
|
|
mtp2Atts2(2)
|
|
,
|
|
mtp2Atts3(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 attributes of singnalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES"
|
|
::= {acSS7LinkTDMEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkTDMCongestionLowMark OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link congestion low mark of signalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_CONGESTION_LOW_MARK"
|
|
::= {acSS7LinkTDMEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkTDMCongestionHighMark OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link congestion high mark of signalling link (TDM).
|
|
Access: Online.
|
|
AC INI-Param: SS7_CONGESTION_HIGH_MARK"
|
|
::= {acSS7LinkTDMEntry 6}
|
|
|
|
|
|
|
|
acSS7LinkTDMBlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
l3linkunblocked(0)
|
|
,
|
|
l3linklocalblocked(1)
|
|
,
|
|
l3linkremoteblockde(2)
|
|
,
|
|
l3linklocalandremotelocked(3)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link blocked indicator.
|
|
AC INI-Param: SS7_LINK_BLOCKED"
|
|
::= {acSS7LinkTDMEntry 7}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSigTran table declaration
|
|
-- ****************************************
|
|
acSS7LinkSigTranTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkSigTranEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Links 23}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSigTran table entry
|
|
-- ****************************************
|
|
acSS7LinkSigTranEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkSigTranEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkCommonIndex}
|
|
::= {acSS7LinkSigTranTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSigTran TABLE
|
|
-- ****************************************
|
|
AcSS7LinkSigTranEntry ::= SEQUENCE {
|
|
acSS7LinkSigTranGroupId Integer32,
|
|
acSS7LinkSigTranIfid Integer32
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkSigTranGroupId OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group ID (M2UA) of signaling link.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_GROUP_ID"
|
|
::= {acSS7LinkSigTranEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkSigTranIfid OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface ID (M2UA) of singnalling link.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_M2UA_IF_ID"
|
|
::= {acSS7LinkSigTranEntry 2}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkATM table declaration
|
|
-- ****************************************
|
|
acSS7LinkATMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkATMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Links 24}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkATM table entry
|
|
-- ****************************************
|
|
acSS7LinkATMEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkATMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkCommonIndex}
|
|
::= {acSS7LinkATMTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkATM TABLE
|
|
-- ****************************************
|
|
AcSS7LinkATMEntry ::= SEQUENCE {
|
|
acSS7LinkATMSAALLinkProfileNum Unsigned32,
|
|
acSS7LinkATMSAALLinkType INTEGER,
|
|
acSS7LinkATMSAALLinkInterfaceNum Unsigned32,
|
|
acSS7LinkATMSAALLinkVPI Unsigned32,
|
|
acSS7LinkATMSAALLinkVCI Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkATMSAALLinkProfileNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..128)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ATM SAAL Link profile number.
|
|
Access: Online.
|
|
AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM"
|
|
::= {acSS7LinkATMEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkATMSAALLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aTM-VCC-Type-PVC(0)
|
|
,
|
|
aTM-VCC-Type-SVC(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ATM SAAL link Type PVC/SVC.
|
|
Access: Online.
|
|
AC INI-Param: ATM_SAAL_LINK_TYPE"
|
|
::= {acSS7LinkATMEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkATMSAALLinkInterfaceNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..128)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ATM SAAL link port num.
|
|
Access: Online.
|
|
AC INI-Param: ATM_SAAL_LINK_PORT_NUM"
|
|
::= {acSS7LinkATMEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkATMSAALLinkVPI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ATM SAAL link VPI.
|
|
Access: Online.
|
|
AC INI-Param: ATM_SAAL_LINK_VPI"
|
|
::= {acSS7LinkATMEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkATMSAALLinkVCI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65536)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ATM SAAL link VCI.
|
|
Access: Online.
|
|
AC INI-Param: ATM_SAAL_LINK_VCI"
|
|
::= {acSS7LinkATMEntry 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTNL table declaration
|
|
-- ****************************************
|
|
acSS7LinkTNLTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkTNLEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Links 25}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTNL table entry
|
|
-- ****************************************
|
|
acSS7LinkTNLEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkTNLEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkCommonIndex}
|
|
::= {acSS7LinkTNLTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkTNL TABLE
|
|
-- ****************************************
|
|
AcSS7LinkTNLEntry ::= SEQUENCE {
|
|
acSS7LinkTNLOtherSideLinkNum Unsigned32,
|
|
acSS7LinkTNLAlignmentMode INTEGER,
|
|
acSS7LinkTNLCongestionMode INTEGER,
|
|
acSS7LinkTNLWaitStartCompTimer Unsigned32,
|
|
acSS7LinkTNLOosStartDelayTimer Unsigned32,
|
|
acSS7LinkTNLWaitOtherSideInsvTimer Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkTNLOtherSideLinkNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling
|
|
link).
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER"
|
|
::= {acSS7LinkTNLEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkTNLAlignmentMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0)
|
|
,
|
|
emergency(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: Alignment mode of signalling links in tunnel.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE"
|
|
::= {acSS7LinkTNLEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkTNLCongestionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
accept(0)
|
|
,
|
|
discard(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: Congestion mode of signalling links in tunnel.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE"
|
|
::= {acSS7LinkTNLEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkTNLWaitStartCompTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: wait start complete timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER"
|
|
::= {acSS7LinkTNLEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkTNLOosStartDelayTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: OOS start delay timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER"
|
|
::= {acSS7LinkTNLEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkTNLWaitOtherSideInsvTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTP2 Tunneling: wait for other side to be in service timer.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER"
|
|
::= {acSS7LinkTNLEntry 6}
|
|
|
|
|
|
|
|
acSS7Nodes OBJECT IDENTIFIER ::= {acSS7Configuration 4}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNode table declaration
|
|
-- ****************************************
|
|
acSS7SignalingNodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7SignalingNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Nodes 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNode table entry
|
|
-- ****************************************
|
|
acSS7SignalingNodeEntry OBJECT-TYPE
|
|
SYNTAX AcSS7SignalingNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7SignalingNodeIndex}
|
|
::= {acSS7SignalingNodeTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SignalingNode TABLE
|
|
-- ****************************************
|
|
AcSS7SignalingNodeEntry ::= SEQUENCE {
|
|
acSS7SignalingNodeIndex Unsigned32,
|
|
acSS7SignalingNodeRowStatus RowStatus,
|
|
acSS7SignalingNodeAction INTEGER,
|
|
acSS7SignalingNodeActionResult INTEGER,
|
|
acSS7SignalingNodeName SnmpAdminString,
|
|
acSS7SignalingNodeTraceLevel INTEGER,
|
|
acSS7SignalingNodeAdminState INTEGER,
|
|
acSS7SignalingNodeOperState INTEGER,
|
|
acSS7SignalingNodeMtcBusy INTEGER,
|
|
acSS7SignalingNodeVariant INTEGER,
|
|
acSS7SignalingNodeNwIndicator INTEGER,
|
|
acSS7SignalingNodeSpStp INTEGER,
|
|
acSS7SignalingNodeTfc INTEGER,
|
|
acSS7SignalingNodeOpc Unsigned32,
|
|
acSS7SignalingNodeRouteSetCongestionWindow Unsigned32,
|
|
acSS7SignalingNodeTimersIdx INTEGER,
|
|
acSS7SignalingNodeIsupApp INTEGER,
|
|
acSS7SignalingNodeSccpApp INTEGER,
|
|
acSS7SignalingNodeBisupApp INTEGER,
|
|
acSS7SignalingNodeAlcapApp INTEGER,
|
|
acSS7SignalingNodeRdcyOpc Unsigned32,
|
|
acSS7SignalingNodeTupApp INTEGER,
|
|
acSS7SignalingNodeBiccApp INTEGER
|
|
}
|
|
|
|
|
|
|
|
acSS7SignalingNodeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: SS7_SN_INDEX"
|
|
::= {acSS7SignalingNodeEntry 1}
|
|
|
|
|
|
|
|
acSS7SignalingNodeRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_SN_ROWSTATUS"
|
|
::= {acSS7SignalingNodeEntry 2}
|
|
|
|
|
|
|
|
acSS7SignalingNodeAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
stop(1)
|
|
,
|
|
start(2)
|
|
,
|
|
inService(3)
|
|
,
|
|
offLine(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_SN_ACTION"
|
|
::= {acSS7SignalingNodeEntry 3}
|
|
|
|
|
|
|
|
acSS7SignalingNodeActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_SN_ACTION_RESULT"
|
|
::= {acSS7SignalingNodeEntry 4}
|
|
|
|
|
|
|
|
acSS7SignalingNodeName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for SN Params.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_NAME"
|
|
::= {acSS7SignalingNodeEntry 5}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTraceLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
traceLevel0(0)
|
|
,
|
|
traceLevel1(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trace level of singnalling node (level 3).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_TRACE_LEVEL"
|
|
::= {acSS7SignalingNodeEntry 6}
|
|
|
|
|
|
|
|
acSS7SignalingNodeAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state of singnalling node.
|
|
AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE"
|
|
::= {acSS7SignalingNodeEntry 7}
|
|
|
|
|
|
|
|
acSS7SignalingNodeOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational state of singnalling node.
|
|
AC INI-Param: SS7_SN_OPERATIONAL_STATE"
|
|
::= {acSS7SignalingNodeEntry 8}
|
|
|
|
|
|
|
|
acSS7SignalingNodeMtcBusy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual busy status of singnalling node.
|
|
AC INI-Param: SS7_SN_MTC_BUSY_STATUS"
|
|
::= {acSS7SignalingNodeEntry 9}
|
|
|
|
|
|
|
|
acSS7SignalingNodeVariant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
itu(1)
|
|
,
|
|
ansi(2)
|
|
,
|
|
china(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Variant of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_VARIANT"
|
|
::= {acSS7SignalingNodeEntry 10}
|
|
|
|
|
|
|
|
acSS7SignalingNodeNwIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
international(0)
|
|
,
|
|
internationalSpare(1)
|
|
,
|
|
national(2)
|
|
,
|
|
nationalSpare(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Indicator of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_NI"
|
|
::= {acSS7SignalingNodeEntry 11}
|
|
|
|
|
|
|
|
acSS7SignalingNodeSpStp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sp(0)
|
|
,
|
|
stp(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routing function of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_SP_STP"
|
|
::= {acSS7SignalingNodeEntry 12}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTfc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TFC function of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_TFC"
|
|
::= {acSS7SignalingNodeEntry 13}
|
|
|
|
|
|
|
|
acSS7SignalingNodeOpc OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Origination (local) point-code of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_OPC"
|
|
::= {acSS7SignalingNodeEntry 14}
|
|
|
|
|
|
|
|
acSS7SignalingNodeRouteSetCongestionWindow OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routeset Congestion Size (messages) of singnalling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE"
|
|
::= {acSS7SignalingNodeEntry 15}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTimersIdx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timersIdx0(0)
|
|
,
|
|
timersIdx1(1)
|
|
,
|
|
timersIdx2(2)
|
|
,
|
|
timersIdx3(3)
|
|
,
|
|
timersIdx4(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of SNTimers table used for this signaling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_TIMERS_INDEX"
|
|
::= {acSS7SignalingNodeEntry 16}
|
|
|
|
|
|
|
|
acSS7SignalingNodeIsupApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nill(0)
|
|
,
|
|
ual(4)
|
|
,
|
|
l4Gen(7)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level 4 application that handles ISUP traffic for this singnalling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_ISUP_APP"
|
|
::= {acSS7SignalingNodeEntry 17}
|
|
|
|
|
|
|
|
acSS7SignalingNodeSccpApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nill(0)
|
|
,
|
|
ual(4)
|
|
,
|
|
l4Gen(7)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level 4 application that handles SCCP traffic for this singnalling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_SCCP_APP"
|
|
::= {acSS7SignalingNodeEntry 18}
|
|
|
|
|
|
|
|
acSS7SignalingNodeBisupApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nill(0)
|
|
,
|
|
ual(4)
|
|
,
|
|
l4Gen(7)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level 4 application that handles BISUP traffic for this singnalling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_BISUP_APP"
|
|
::= {acSS7SignalingNodeEntry 19}
|
|
|
|
|
|
|
|
acSS7SignalingNodeAlcapApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nill(0)
|
|
,
|
|
ual(4)
|
|
,
|
|
alcap(5)
|
|
,
|
|
l4Gen(7)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Level 4 application that handles ALCAP traffic for this singnalling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_ALCAP_APP"
|
|
::= {acSS7SignalingNodeEntry 20}
|
|
|
|
|
|
|
|
acSS7SignalingNodeRdcyOpc OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal point-code of singnalling node - in case of SS7 shared
|
|
point code.
|
|
AC INI-Param: SS7_SN_RDCY_OPC"
|
|
::= {acSS7SignalingNodeEntry 21}
|
|
|
|
|
|
|
|
acSS7SignalingNodeTupApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nill(0)
|
|
,
|
|
ual(4)
|
|
,
|
|
l4Gen(7)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level 4 application that handles TUP traffic for this signaling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_TUP_APP"
|
|
::= {acSS7SignalingNodeEntry 22}
|
|
|
|
|
|
|
|
acSS7SignalingNodeBiccApp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nil(0)
|
|
,
|
|
ual(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level 4 application that handles BICC traffic for this signaling
|
|
node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SN_BICC_APP"
|
|
::= {acSS7SignalingNodeEntry 23}
|
|
|
|
|
|
|
|
acSS7LinkSets OBJECT IDENTIFIER ::= {acSS7Nodes 31}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSet table declaration
|
|
-- ****************************************
|
|
acSS7LinkSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7LinkSets 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSet table entry
|
|
-- ****************************************
|
|
acSS7LinkSetEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkSetSNIndex,acSS7LinkSetLksetIndex}
|
|
::= {acSS7LinkSetTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSet TABLE
|
|
-- ****************************************
|
|
AcSS7LinkSetEntry ::= SEQUENCE {
|
|
acSS7LinkSetSNIndex Unsigned32,
|
|
acSS7LinkSetLksetIndex Unsigned32,
|
|
acSS7LinkSetRowStatus RowStatus,
|
|
acSS7LinkSetAction INTEGER,
|
|
acSS7LinkSetActionResult INTEGER,
|
|
acSS7LinkSetName SnmpAdminString,
|
|
acSS7LinkSetAdminState INTEGER,
|
|
acSS7LinkSetOperState INTEGER,
|
|
acSS7LinkSetMtcBusyState INTEGER,
|
|
acSS7LinkSetDPC Unsigned32,
|
|
acSS7LinkSetLinksMask Unsigned32,
|
|
acSS7LinkSetLinksAltMask Unsigned32,
|
|
acSS7LinkSetTimersIdx INTEGER
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkSetSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index Field for line.
|
|
AC INI-Param: SS7_LINKSET_SN_INDEX"
|
|
::= {acSS7LinkSetEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkSetLksetIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index Field for line.
|
|
AC INI-Param: SS7_LINKSET_LINKSET_INDEX"
|
|
::= {acSS7LinkSetEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkSetRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_LINKSET_ROWSTATUS"
|
|
::= {acSS7LinkSetEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkSetAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
offLine(1)
|
|
,
|
|
inService(2)
|
|
,
|
|
activate(3)
|
|
,
|
|
deActivate(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_LINKSET_ACTION"
|
|
::= {acSS7LinkSetEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkSetActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_SN_ACTION_RESULT"
|
|
::= {acSS7LinkSetEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkSetName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for LINKSET Params.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSET_NAME"
|
|
::= {acSS7LinkSetEntry 6}
|
|
|
|
|
|
|
|
acSS7LinkSetAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state of singnalling linkset.
|
|
AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE"
|
|
::= {acSS7LinkSetEntry 7}
|
|
|
|
|
|
|
|
acSS7LinkSetOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational state of singnalling linkset.
|
|
AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE"
|
|
::= {acSS7LinkSetEntry 8}
|
|
|
|
|
|
|
|
acSS7LinkSetMtcBusyState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual busy status of singnalling linkset.
|
|
AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS"
|
|
::= {acSS7LinkSetEntry 9}
|
|
|
|
|
|
|
|
acSS7LinkSetDPC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination Point-Code of singnalling linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSET_DPC"
|
|
::= {acSS7LinkSetEntry 10}
|
|
|
|
|
|
|
|
acSS7LinkSetLinksMask OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mask for links within singnalling linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSET_MASK"
|
|
::= {acSS7LinkSetEntry 11}
|
|
|
|
|
|
|
|
acSS7LinkSetLinksAltMask OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alternate mask for links within singnalling linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSET_ALTERNATE_MASK"
|
|
::= {acSS7LinkSetEntry 12}
|
|
|
|
|
|
|
|
acSS7LinkSetTimersIdx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timersIdx0(0)
|
|
,
|
|
timersIdx1(1)
|
|
,
|
|
timersIdx2(2)
|
|
,
|
|
timersIdx3(3)
|
|
,
|
|
timersIdx4(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timers Index of singnalling linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSET_TIMERS_INDEX"
|
|
::= {acSS7LinkSetEntry 13}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetLink table declaration
|
|
-- ****************************************
|
|
acSS7LinkSetLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7LinkSetLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7LinkSets 22}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetLink table entry
|
|
-- ****************************************
|
|
acSS7LinkSetLinkEntry OBJECT-TYPE
|
|
SYNTAX AcSS7LinkSetLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7LinkSetLinkSNIndex,acSS7LinkSetLinkLinksetIndex,acSS7LinkSetLinkInnerLinkIndex}
|
|
::= {acSS7LinkSetLinkTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7LinkSetLink TABLE
|
|
-- ****************************************
|
|
AcSS7LinkSetLinkEntry ::= SEQUENCE {
|
|
acSS7LinkSetLinkSNIndex Unsigned32,
|
|
acSS7LinkSetLinkLinksetIndex Unsigned32,
|
|
acSS7LinkSetLinkInnerLinkIndex Unsigned32,
|
|
acSS7LinkSetLinkRowStatus RowStatus,
|
|
acSS7LinkSetLinkAction INTEGER,
|
|
acSS7LinkSetLinkActionResult INTEGER,
|
|
acSS7LinkSetLinkLinkNo Unsigned32,
|
|
acSS7LinkSetLinkLinkSlc Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index Field for line: Signalling Node Number.
|
|
AC INI-Param: SS7_LINKSETLINK_SN_INDEX"
|
|
::= {acSS7LinkSetLinkEntry 1}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkLinksetIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index Field for line: Signalling Linkset Number.
|
|
AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX"
|
|
::= {acSS7LinkSetLinkEntry 2}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkInnerLinkIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Third Index Field for line: Inner Link Index in Signalling Linkset.
|
|
AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX"
|
|
::= {acSS7LinkSetLinkEntry 3}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_LINKSETLINK_ROWSTATUS"
|
|
::= {acSS7LinkSetLinkEntry 4}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_LINKSETLINK_ACTION"
|
|
::= {acSS7LinkSetLinkEntry 5}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT"
|
|
::= {acSS7LinkSetLinkEntry 6}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkLinkNo OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical number of signalling link which is part of the Linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER"
|
|
::= {acSS7LinkSetLinkEntry 7}
|
|
|
|
|
|
|
|
acSS7LinkSetLinkLinkSlc OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLC number of signaling link which is part of the Linkset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LINKSETLINK_LINK_SLC"
|
|
::= {acSS7LinkSetLinkEntry 8}
|
|
|
|
|
|
|
|
acSS7RouteSets OBJECT IDENTIFIER ::= {acSS7Nodes 32}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSet table declaration
|
|
-- ****************************************
|
|
acSS7RouteSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7RouteSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7RouteSets 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSet table entry
|
|
-- ****************************************
|
|
acSS7RouteSetEntry OBJECT-TYPE
|
|
SYNTAX AcSS7RouteSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7RouteSetSNIndex,acSS7RouteSetIndex}
|
|
::= {acSS7RouteSetTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSet TABLE
|
|
-- ****************************************
|
|
AcSS7RouteSetEntry ::= SEQUENCE {
|
|
acSS7RouteSetSNIndex Unsigned32,
|
|
acSS7RouteSetIndex Unsigned32,
|
|
acSS7RouteSetRowStatus RowStatus,
|
|
acSS7RouteSetAction INTEGER,
|
|
acSS7RouteSetActionResult INTEGER,
|
|
acSS7RouteSetName SnmpAdminString,
|
|
acSS7RouteSetAdminState INTEGER,
|
|
acSS7RouteSetOperState INTEGER,
|
|
acSS7RouteSetDPC Unsigned32,
|
|
acSS7RouteSetRouteMask Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7RouteSetSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index Field for line: Signalling Node Number.
|
|
AC INI-Param: SS7_ROUTESET_SN_INDEX"
|
|
::= {acSS7RouteSetEntry 1}
|
|
|
|
|
|
|
|
acSS7RouteSetIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..29)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index Field for line: Signalling Routeset Number.
|
|
AC INI-Param: SS7_ROUTESET_INDEX"
|
|
::= {acSS7RouteSetEntry 2}
|
|
|
|
|
|
|
|
acSS7RouteSetRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_ROUTESET_ROWSTATUS"
|
|
::= {acSS7RouteSetEntry 3}
|
|
|
|
|
|
|
|
acSS7RouteSetAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
offLine(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_ROUTESET_ACTION"
|
|
::= {acSS7RouteSetEntry 4}
|
|
|
|
|
|
|
|
acSS7RouteSetActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_ROUTESET_ACTION_RESULT"
|
|
::= {acSS7RouteSetEntry 5}
|
|
|
|
|
|
|
|
acSS7RouteSetName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for ROUTESET Params.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ROUTESET_NAME"
|
|
::= {acSS7RouteSetEntry 6}
|
|
|
|
|
|
|
|
acSS7RouteSetAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state of signalling route set.
|
|
AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE"
|
|
::= {acSS7RouteSetEntry 7}
|
|
|
|
|
|
|
|
acSS7RouteSetOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational state of signalling route set.
|
|
AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE"
|
|
::= {acSS7RouteSetEntry 8}
|
|
|
|
|
|
|
|
acSS7RouteSetDPC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination Point-Code of singnalling routesetset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ROUTESET_DPC"
|
|
::= {acSS7RouteSetEntry 9}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteMask OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mask for route within signaling routeset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ROUTESET_MASK"
|
|
::= {acSS7RouteSetEntry 10}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSetRoute table declaration
|
|
-- ****************************************
|
|
acSS7RouteSetRouteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7RouteSetRouteEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7RouteSets 22}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSetRoute table entry
|
|
-- ****************************************
|
|
acSS7RouteSetRouteEntry OBJECT-TYPE
|
|
SYNTAX AcSS7RouteSetRouteEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7RouteSetRouteSNIndex,acSS7RouteSetRouteRoutesetIndex,acSS7RouteSetRouteInnerRouteIndex}
|
|
::= {acSS7RouteSetRouteTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RouteSetRoute TABLE
|
|
-- ****************************************
|
|
AcSS7RouteSetRouteEntry ::= SEQUENCE {
|
|
acSS7RouteSetRouteSNIndex Unsigned32,
|
|
acSS7RouteSetRouteRoutesetIndex Unsigned32,
|
|
acSS7RouteSetRouteInnerRouteIndex Unsigned32,
|
|
acSS7RouteSetRouteRowStatus RowStatus,
|
|
acSS7RouteSetRouteAction INTEGER,
|
|
acSS7RouteSetRouteActionResult INTEGER,
|
|
acSS7RouteSetRouteLinkSetNo Unsigned32,
|
|
acSS7RouteSetRoutePriority Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index Field for line: Signalling Node Number.
|
|
AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX"
|
|
::= {acSS7RouteSetRouteEntry 1}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteRoutesetIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..29)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index Field for line: Signalling Routeset Number.
|
|
AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX"
|
|
::= {acSS7RouteSetRouteEntry 2}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteInnerRouteIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..3)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Third Index Field for line: Inner Route Index in Signalling
|
|
Routeset.
|
|
AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX"
|
|
::= {acSS7RouteSetRouteEntry 3}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS"
|
|
::= {acSS7RouteSetRouteEntry 4}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS.
|
|
AC INI-Param: SS7_ROUTESETROUTE_ACTION"
|
|
::= {acSS7RouteSetRouteEntry 5}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT"
|
|
::= {acSS7RouteSetRouteEntry 6}
|
|
|
|
|
|
|
|
acSS7RouteSetRouteLinkSetNo OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of signalling linkset which is part of the Routeset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER"
|
|
::= {acSS7RouteSetRouteEntry 7}
|
|
|
|
|
|
|
|
acSS7RouteSetRoutePriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..254)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Priority of route within routeset.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ROUTESETROUTE_PRIORITY"
|
|
::= {acSS7RouteSetRouteEntry 8}
|
|
|
|
|
|
|
|
acSS7AliasPointCode OBJECT IDENTIFIER ::= {acSS7Nodes 33}
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7APC table declaration
|
|
-- ****************************************
|
|
acSS7APCTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7APCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7AliasPointCode 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7APC table entry
|
|
-- ****************************************
|
|
acSS7APCEntry OBJECT-TYPE
|
|
SYNTAX AcSS7APCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7APCSNIndex,acSS7APCIndex}
|
|
::= {acSS7APCTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7APC TABLE
|
|
-- ****************************************
|
|
AcSS7APCEntry ::= SEQUENCE {
|
|
acSS7APCSNIndex Unsigned32,
|
|
acSS7APCIndex Unsigned32,
|
|
acSS7APCRowStatus RowStatus,
|
|
acSS7APCAction INTEGER,
|
|
acSS7APCActionResult INTEGER,
|
|
acSS7APCPC Unsigned32,
|
|
acSS7APCSNI Unsigned32,
|
|
acSS7APCName SnmpAdminString,
|
|
acSS7APCMtcBusy INTEGER,
|
|
acSS7APCAdminState INTEGER,
|
|
acSS7APCOperState INTEGER
|
|
}
|
|
|
|
|
|
|
|
acSS7APCSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index Field for line: Signaling Node Number.
|
|
AC INI-Param: SS7_APC_SN_INDEX"
|
|
::= {acSS7APCEntry 1}
|
|
|
|
|
|
|
|
acSS7APCIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index Field for line: Alias PC index.
|
|
AC INI-Param: SS7_APC_INNER_INDEX"
|
|
::= {acSS7APCEntry 2}
|
|
|
|
|
|
|
|
acSS7APCRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS Field for line.
|
|
AC INI-Param: SS7_APC_ROWSTATUS"
|
|
::= {acSS7APCEntry 3}
|
|
|
|
|
|
|
|
acSS7APCAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
offLine(1)
|
|
,
|
|
inService(2)
|
|
,
|
|
activate(3)
|
|
,
|
|
deActivate(4)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTIONS.
|
|
AC INI-Param: SS7_APC_ACTION"
|
|
::= {acSS7APCEntry 4}
|
|
|
|
|
|
|
|
acSS7APCActionResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
succeeded(0)
|
|
,
|
|
inProgress(1)
|
|
,
|
|
failed(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"management Field for ACTIONS RESULT.
|
|
AC INI-Param: SS7_APC_ACTION_RESULT"
|
|
::= {acSS7APCEntry 5}
|
|
|
|
|
|
|
|
acSS7APCPC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alias Point-Code of signaling node.
|
|
Access: Online.
|
|
AC INI-Param: SS7_APC_PC"
|
|
::= {acSS7APCEntry 6}
|
|
|
|
|
|
|
|
acSS7APCSNI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (2..5)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNI (Signaling Network Indicator) of Alias Point-Code.
|
|
Access: Online.
|
|
AC INI-Param: SS7_APC_SNI"
|
|
::= {acSS7APCEntry 7}
|
|
|
|
|
|
|
|
acSS7APCName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String name for Alias PC parameters.
|
|
Access: Online.
|
|
AC INI-Param: SS7_ALIAS_PC_NAME"
|
|
::= {acSS7APCEntry 8}
|
|
|
|
|
|
|
|
acSS7APCMtcBusy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
,
|
|
yes(1)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual busy status of Alias PC.
|
|
AC INI-Param: SS7_ALIAS_PC_MTC_BUSY"
|
|
::= {acSS7APCEntry 9}
|
|
|
|
|
|
|
|
acSS7APCAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state of Alias PC.
|
|
AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE"
|
|
::= {acSS7APCEntry 10}
|
|
|
|
|
|
|
|
acSS7APCOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
offLine(0)
|
|
,
|
|
busy(1)
|
|
,
|
|
inService(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational state of Alias PC.
|
|
AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE"
|
|
::= {acSS7APCEntry 11}
|
|
|
|
|
|
|
|
acSS7SigTran OBJECT IDENTIFIER ::= {acSS7Configuration 5}
|
|
|
|
|
|
acSS7SigTranM3UATrafficBehavior OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
deactivate(1)
|
|
,
|
|
sIPO(2)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the M3UA behavior when the SS7 links are up, but there
|
|
is no association to the soft switch.
|
|
|
|
0 = NONE (no special behavior)
|
|
1 = DEACTIVATE (busy links)
|
|
2 = SIPO (LPO links).
|
|
Access: Offline.
|
|
AC INI-Param: SS7M3UATrafficBehavior"
|
|
::= {acSS7SigTran 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFGroup table declaration
|
|
-- ****************************************
|
|
acSS7SigTranIFGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7SigTranIFGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7SigTran 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFGroup table entry
|
|
-- ****************************************
|
|
acSS7SigTranIFGroupEntry OBJECT-TYPE
|
|
SYNTAX AcSS7SigTranIFGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7SigTranIFGroupIndex}
|
|
::= {acSS7SigTranIFGroupTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFGroup TABLE
|
|
-- ****************************************
|
|
AcSS7SigTranIFGroupEntry ::= SEQUENCE {
|
|
acSS7SigTranIFGroupIndex Unsigned32,
|
|
acSS7SigTranIFGroupRowStatus RowStatus,
|
|
acSS7SigTranIFGroupAction INTEGER,
|
|
acSS7SigTranIFGroupActionResult Unsigned32,
|
|
acSS7SigTranIFGroupId Unsigned32,
|
|
acSS7SigTranIFGroupSgMgc INTEGER,
|
|
acSS7SigTranIFGroupSignalingLayer INTEGER,
|
|
acSS7SigTranIFGroupTrafMode INTEGER,
|
|
acSS7SigTranIFGroupRecovTimer Unsigned32,
|
|
acSS7SigTranIFGroupAckTimer Unsigned32,
|
|
acSS7SigTranIFGroupHBTimer Unsigned32,
|
|
acSS7SigTranIFGroupMinAsp Unsigned32,
|
|
acSS7SigTranIFGroupBehavior Unsigned32,
|
|
acSS7SigTranIFGroupSCTPInst Unsigned32,
|
|
acSS7SigTranIFGroupSCTPLocalPort Unsigned32,
|
|
acSS7SigTranIFGroupNetwork INTEGER,
|
|
acSS7SigTranIFGroupSCTPDestPort Unsigned32,
|
|
acSS7SigTranIFGroupDestIp IpAddress,
|
|
acSS7SigTranIFGroupSCTPMaxInbStreams Unsigned32,
|
|
acSS7SigTranIFGroupSCTPMaxOutbStreams Unsigned32,
|
|
acSS7SigTranIFGroupRdcyBoardNum Unsigned32,
|
|
acSS7SigTranIFGroupRoutingContextIndex Integer32,
|
|
acSS7SigTranIFGroupRoutingContextValue Integer32,
|
|
acSS7SigTranIFGroupNetworkAppearance Integer32
|
|
}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index field for line.
|
|
AC INI-Param: SS7_SIG_IF_GR_INDEX"
|
|
::= {acSS7SigTranIFGroupEntry 1}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS field for line.
|
|
AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS"
|
|
::= {acSS7SigTranIFGroupEntry 2}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
activate(1)
|
|
,
|
|
deActivate(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION.
|
|
AC INI-Param: SS7_SIG_IF_GR_ACTION"
|
|
::= {acSS7SigTranIFGroupEntry 3}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupActionResult OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION RESULT.
|
|
AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT"
|
|
::= {acSS7SigTranIFGroupEntry 4}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface
|
|
Group Id.
|
|
Access: Online.
|
|
AC INI-Param: SS7_IF_GR_ID"
|
|
::= {acSS7SigTranIFGroupEntry 5}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSgMgc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nat(1)
|
|
,
|
|
mgc(77)
|
|
,
|
|
sg(83)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface Group function - Signaling Gateway (SG) or Media Gateway
|
|
Controller (MGC).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_SG_MGC"
|
|
::= {acSS7SigTranIFGroupEntry 6}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSignalingLayer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLayer(0)
|
|
,
|
|
iua(1)
|
|
,
|
|
m2ua(2)
|
|
,
|
|
m3ua(3)
|
|
,
|
|
m2tunnel(4)
|
|
,
|
|
dua(6)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UAL type of interface group:
|
|
0 = none
|
|
1 = iua
|
|
2 = m2ua
|
|
3 = m3ua
|
|
4 = m2tunnel
|
|
6 = dua.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_LAYER"
|
|
::= {acSS7SigTranIFGroupEntry 7}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupTrafMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
override(1)
|
|
,
|
|
loadShare(2)
|
|
,
|
|
broadcast(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic mode of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_TRAF_MODE"
|
|
::= {acSS7SigTranIFGroupEntry 8}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupRecovTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10000000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T(r) - recovery timer (in msecs) of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_T_REC"
|
|
::= {acSS7SigTranIFGroupEntry 9}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupAckTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10000000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_T_ACK"
|
|
::= {acSS7SigTranIFGroupEntry 10}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupHBTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..10000000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T(beat) - Heartbeat Timer (in msecs) of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_T_HB"
|
|
::= {acSS7SigTranIFGroupEntry 11}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupMinAsp OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal ASP (Application Server Process) number in interface
|
|
group(minimum = 1).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_MIN_ASP"
|
|
::= {acSS7SigTranIFGroupEntry 12}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupBehavior OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Behavior bit of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_BEHAVIOUR"
|
|
::= {acSS7SigTranIFGroupEntry 13}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSCTPInst OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65534)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SCTP (Stream Control Transmission Protocol) instance of interface
|
|
group.
|
|
AC INI-Param: SS7_SCTP_INSTANCE"
|
|
::= {acSS7SigTranIFGroupEntry 14}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSCTPLocalPort OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local SCTP (Stream Control Transmission Protocol) port of interface
|
|
group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_LOCAL_SCTP_PORT"
|
|
::= {acSS7SigTranIFGroupEntry 15}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupNetwork OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
itu(1)
|
|
,
|
|
ansi(2)
|
|
,
|
|
china(3)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network variant of interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_NETWORK"
|
|
::= {acSS7SigTranIFGroupEntry 16}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSCTPDestPort OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination SCTP (Stream Control Transmission Protocol) port.
|
|
Access: Online.
|
|
AC INI-Param: SS7_DEST_SCTP_PORT"
|
|
::= {acSS7SigTranIFGroupEntry 17}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupDestIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination SCTP (Stream Control Transmission Protocol) IP address.
|
|
Access: Online.
|
|
AC INI-Param: SS7_DEST_IP"
|
|
::= {acSS7SigTranIFGroupEntry 18}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSCTPMaxInbStreams OBJECT-TYPE
|
|
SYNTAX Unsigned32 (2..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum inbound streams in interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_MGC_MX_IN_STREAM"
|
|
::= {acSS7SigTranIFGroupEntry 19}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupSCTPMaxOutbStreams OBJECT-TYPE
|
|
SYNTAX Unsigned32 (2..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of output streams required in interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_MGC_NUM_OUT_STREAM"
|
|
::= {acSS7SigTranIFGroupEntry 20}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupRdcyBoardNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the SIGTRAN (Signaling Transport)
|
|
group redundancy board number.
|
|
Access: Online.
|
|
AC INI-Param: RdcyBoardNum"
|
|
::= {acSS7SigTranIFGroupEntry 21}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupRoutingContextIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry in Routing Context table, that contains the routing context
|
|
rules for this interface group.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_RC_INDEX"
|
|
::= {acSS7SigTranIFGroupEntry 22}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupRoutingContextValue OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routing context value for this interface group (AS).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_RC_VALUE"
|
|
::= {acSS7SigTranIFGroupEntry 23}
|
|
|
|
|
|
|
|
acSS7SigTranIFGroupNetworkAppearance OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Appearance value for this interface group (AS).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_NETWORK_APPEARANCE"
|
|
::= {acSS7SigTranIFGroupEntry 24}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFID table declaration
|
|
-- ****************************************
|
|
acSS7SigTranIFIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7SigTranIFIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7SigTran 22}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFID table entry
|
|
-- ****************************************
|
|
acSS7SigTranIFIDEntry OBJECT-TYPE
|
|
SYNTAX AcSS7SigTranIFIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7SigTranIFIDIndex}
|
|
::= {acSS7SigTranIFIDTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranIFID TABLE
|
|
-- ****************************************
|
|
AcSS7SigTranIFIDEntry ::= SEQUENCE {
|
|
acSS7SigTranIFIDIndex Unsigned32,
|
|
acSS7SigTranIFIDRowStatus RowStatus,
|
|
acSS7SigTranIFIDAction INTEGER,
|
|
acSS7SigTranIFIDActionResult Unsigned32,
|
|
acSS7SigTranIFIDValue Unsigned32,
|
|
acSS7SigTranIFIDName SnmpAdminString,
|
|
acSS7SigTranIFIDOwnerGroup Integer32,
|
|
acSS7SigTranIFIDSignalingLayer INTEGER,
|
|
acSS7SigTranIFIDNai Integer32,
|
|
acSS7SigTranIFIDM3UASpc Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..83)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index field for line.
|
|
AC INI-Param: SS7_SIG_IF_ID_INDEX"
|
|
::= {acSS7SigTranIFIDEntry 1}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS field for line.
|
|
AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS"
|
|
::= {acSS7SigTranIFIDEntry 2}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
activate(1)
|
|
,
|
|
deActivate(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION.
|
|
AC INI-Param: SS7_SIG_IF_ID_ACTION"
|
|
::= {acSS7SigTranIFIDEntry 3}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDActionResult OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION RESULT.
|
|
AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT"
|
|
::= {acSS7SigTranIFIDEntry 4}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDValue OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface
|
|
ID value.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_IF_ID_VALUE"
|
|
::= {acSS7SigTranIFIDEntry 5}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..15))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface
|
|
ID name (text string).
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_IF_ID_NAME"
|
|
::= {acSS7SigTranIFIDEntry 6}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDOwnerGroup OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..65534)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Owner group of interface id.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP"
|
|
::= {acSS7SigTranIFIDEntry 7}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDSignalingLayer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLayer(0)
|
|
,
|
|
iua(1)
|
|
,
|
|
m2ua(2)
|
|
,
|
|
m2tunnel(4)
|
|
,
|
|
dua(6)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UAL Type of interface id:
|
|
0 = none
|
|
1 = iua
|
|
2 = m2ua
|
|
4 = m2tunnel
|
|
6 = dua.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_IF_ID_LAYER"
|
|
::= {acSS7SigTranIFIDEntry 8}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDNai OBJECT-TYPE
|
|
SYNTAX Integer32 (-2..124)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NAI of interface id.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_IF_ID_NAI"
|
|
::= {acSS7SigTranIFIDEntry 9}
|
|
|
|
|
|
|
|
acSS7SigTranIFIDM3UASpc OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the SIGTRAN (Signaling Transport)
|
|
M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC.
|
|
Access: Online.
|
|
AC INI-Param: SS7_SIG_M3UA_SPC"
|
|
::= {acSS7SigTranIFIDEntry 10}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7M3UAStaticRouting table declaration
|
|
-- ****************************************
|
|
acSS7M3UAStaticRoutingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7M3UAStaticRoutingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7SigTran 23}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7M3UAStaticRouting table entry
|
|
-- ****************************************
|
|
acSS7M3UAStaticRoutingEntry OBJECT-TYPE
|
|
SYNTAX AcSS7M3UAStaticRoutingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7M3UAStaticRoutingIndex}
|
|
::= {acSS7M3UAStaticRoutingTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7M3UAStaticRouting TABLE
|
|
-- ****************************************
|
|
AcSS7M3UAStaticRoutingEntry ::= SEQUENCE {
|
|
acSS7M3UAStaticRoutingIndex Unsigned32,
|
|
acSS7M3UAStaticRoutingRowStatus RowStatus,
|
|
acSS7M3UAStaticRoutingAction INTEGER,
|
|
acSS7M3UAStaticRoutingActionResult Unsigned32,
|
|
acSS7M3UAStaticRoutingOwnerInterfaceGroup Unsigned32,
|
|
acSS7M3UAStaticRoutingRC Unsigned32,
|
|
acSS7M3UAStaticRoutingDestinationPointCode Unsigned32,
|
|
acSS7M3UAStaticRoutingNetworkAppearence Unsigned32,
|
|
acSS7M3UAStaticRoutingSeriviceIndicatorList Unsigned32,
|
|
acSS7M3UAStaticRoutingOPC1 Unsigned32,
|
|
acSS7M3UAStaticRoutingOPC2 Unsigned32,
|
|
acSS7M3UAStaticRoutingOPC3 Unsigned32,
|
|
acSS7M3UAStaticRoutingOPC4 Unsigned32,
|
|
acSS7M3UAStaticRoutingLowerCICValue1 Unsigned32,
|
|
acSS7M3UAStaticRoutingUpperCICValue1 Unsigned32,
|
|
acSS7M3UAStaticRoutingLowerCICValue2 Unsigned32,
|
|
acSS7M3UAStaticRoutingUpperCICValue2 Unsigned32,
|
|
acSS7M3UAStaticRoutingLowerCICValue3 Unsigned32,
|
|
acSS7M3UAStaticRoutingUpperCICValue3 Unsigned32,
|
|
acSS7M3UAStaticRoutingLowerCICValue4 Unsigned32,
|
|
acSS7M3UAStaticRoutingUpperCICValue4 Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This parameter is used for the Signaling System 7 (SS7) interface
|
|
ID index, for a line.
|
|
AC INI-Param: M3UAROUTINGCLIST_Index"
|
|
::= {acSS7M3UAStaticRoutingEntry 1}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This parameter is used for the Signaling System 7 (SS7) interface
|
|
ID row status, for a line.
|
|
AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS"
|
|
::= {acSS7M3UAStaticRoutingEntry 2}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
activate(1)
|
|
,
|
|
deActivate(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This parameter is used for Signaling System 7 (SS7) SIGTRAN
|
|
(Signaling Transport) interface ID management, for actions.
|
|
AC INI-Param: SS7_SIG_IF_ID_ACTION"
|
|
::= {acSS7M3UAStaticRoutingEntry 3}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingActionResult OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This parameter is used for Signaling System 7 (SS7) SIGTRAN
|
|
(Signaling Transport) interface ID management, for an action's
|
|
results.
|
|
AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT"
|
|
::= {acSS7M3UAStaticRoutingEntry 4}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingOwnerInterfaceGroup OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..30)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup"
|
|
::= {acSS7M3UAStaticRoutingEntry 5}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingRC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_RoutingContext"
|
|
::= {acSS7M3UAStaticRoutingEntry 6}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingDestinationPointCode OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode"
|
|
::= {acSS7M3UAStaticRoutingEntry 7}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingNetworkAppearence OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence"
|
|
::= {acSS7M3UAStaticRoutingEntry 8}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingSeriviceIndicatorList OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList"
|
|
::= {acSS7M3UAStaticRoutingEntry 9}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingOPC1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_OPC1"
|
|
::= {acSS7M3UAStaticRoutingEntry 10}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingOPC2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_OPC2"
|
|
::= {acSS7M3UAStaticRoutingEntry 11}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingOPC3 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_OPC3"
|
|
::= {acSS7M3UAStaticRoutingEntry 12}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingOPC4 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_OPC4"
|
|
::= {acSS7M3UAStaticRoutingEntry 13}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingLowerCICValue1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1"
|
|
::= {acSS7M3UAStaticRoutingEntry 14}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingUpperCICValue1 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1"
|
|
::= {acSS7M3UAStaticRoutingEntry 15}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingLowerCICValue2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2"
|
|
::= {acSS7M3UAStaticRoutingEntry 16}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingUpperCICValue2 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2"
|
|
::= {acSS7M3UAStaticRoutingEntry 17}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingLowerCICValue3 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3"
|
|
::= {acSS7M3UAStaticRoutingEntry 18}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingUpperCICValue3 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3"
|
|
::= {acSS7M3UAStaticRoutingEntry 19}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingLowerCICValue4 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4"
|
|
::= {acSS7M3UAStaticRoutingEntry 20}
|
|
|
|
|
|
|
|
acSS7M3UAStaticRoutingUpperCICValue4 OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Routing Context list - for M3UA use.
|
|
Access: Online.
|
|
AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4"
|
|
::= {acSS7M3UAStaticRoutingEntry 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranRoutingContext table declaration
|
|
-- ****************************************
|
|
acSS7SigTranRoutingContextTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7SigTranRoutingContextEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7SigTran 24}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranRoutingContext table entry
|
|
-- ****************************************
|
|
acSS7SigTranRoutingContextEntry OBJECT-TYPE
|
|
SYNTAX AcSS7SigTranRoutingContextEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7SigTranRoutingContextIndex,acSS7SigTranRoutingContextInnerIndex}
|
|
::= {acSS7SigTranRoutingContextTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7SigTranRoutingContext TABLE
|
|
-- ****************************************
|
|
AcSS7SigTranRoutingContextEntry ::= SEQUENCE {
|
|
acSS7SigTranRoutingContextIndex Unsigned32,
|
|
acSS7SigTranRoutingContextInnerIndex Unsigned32,
|
|
acSS7SigTranRoutingContextRowStatus RowStatus,
|
|
acSS7SigTranRoutingContextAction INTEGER,
|
|
acSS7SigTranRoutingContextActionResult Unsigned32,
|
|
acSS7SigTranRoutingContextSnIdx Unsigned32,
|
|
acSS7SigTranRoutingContextSpc Integer32,
|
|
acSS7SigTranRoutingContextOpc1 Integer32,
|
|
acSS7SigTranRoutingContextOpc2 Integer32,
|
|
acSS7SigTranRoutingContextOpc3 Integer32,
|
|
acSS7SigTranRoutingContextOpc4 Integer32,
|
|
acSS7SigTranRoutingContextSi1 Integer32,
|
|
acSS7SigTranRoutingContextSi2 Integer32,
|
|
acSS7SigTranRoutingContextSi3 Integer32,
|
|
acSS7SigTranRoutingContextSi4 Integer32
|
|
}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First index field for line.
|
|
AC INI-Param: SS7_RC_INDEX"
|
|
::= {acSS7SigTranRoutingContextEntry 1}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextInnerIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..3)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second index field for line.
|
|
AC INI-Param: SS7_RC_INNER_INDEX"
|
|
::= {acSS7SigTranRoutingContextEntry 2}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS field for line.
|
|
AC INI-Param: SS7_RC_ROW_STATUS"
|
|
::= {acSS7SigTranRoutingContextEntry 3}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
activate(1)
|
|
,
|
|
deActivate(2)
|
|
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTIONS.
|
|
AC INI-Param: RCAction"
|
|
::= {acSS7SigTranRoutingContextEntry 4}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextActionResult OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RCActionRes.
|
|
AC INI-Param: SS7_RC_ACTION_RES"
|
|
::= {acSS7SigTranRoutingContextEntry 5}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSnIdx OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..5)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context DPC
|
|
SN-Index.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_SN_INDEX"
|
|
::= {acSS7SigTranRoutingContextEntry 6}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSpc OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..16777215)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context DPC
|
|
parameter.
|
|
AC INI-Param: SS7_RC_SPC"
|
|
::= {acSS7SigTranRoutingContextEntry 7}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextOpc1 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,First
|
|
element of OPC list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_OPC1"
|
|
::= {acSS7SigTranRoutingContextEntry 8}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextOpc2 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,Second
|
|
element of OPC list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_OPC2"
|
|
::= {acSS7SigTranRoutingContextEntry 9}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextOpc3 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
Third element of OPC list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_OPC3"
|
|
::= {acSS7SigTranRoutingContextEntry 10}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextOpc4 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..16777215)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
Fourth element of OPC list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_OPC4"
|
|
::= {acSS7SigTranRoutingContextEntry 11}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSi1 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
First element of SI list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_SI1"
|
|
::= {acSS7SigTranRoutingContextEntry 12}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSi2 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
Second element of SI list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_SI2"
|
|
::= {acSS7SigTranRoutingContextEntry 13}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSi3 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
Third element of SI list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_SI3"
|
|
::= {acSS7SigTranRoutingContextEntry 14}
|
|
|
|
|
|
|
|
acSS7SigTranRoutingContextSi4 OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used to specify the M3UA Routing Context,
|
|
Fourth element of SI list.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RC_SI4"
|
|
::= {acSS7SigTranRoutingContextEntry 15}
|
|
|
|
|
|
|
|
acSS7Redundancy OBJECT IDENTIFIER ::= {acSS7Configuration 6}
|
|
|
|
|
|
acSS7RedundancyCrossLinkTransferType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0)
|
|
,
|
|
tcp(2)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the cross-board connection media type for the MTP3 redundancy
|
|
feature:
|
|
0 = M3BRDCY_CONN_TYPE_NONE
|
|
2 = M3BRDCY_CONN_TYPE_TCP.
|
|
Access: Offline.
|
|
AC INI-Param: SS7MTP3RdcyTransferType"
|
|
::= {acSS7Redundancy 1}
|
|
|
|
|
|
|
|
acSS7RedundancyMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0)
|
|
,
|
|
enable(1)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the MTP3 Signaling redundancy mode:
|
|
0 = Disabled
|
|
1 = Enabled
|
|
.
|
|
Access: Offline.
|
|
AC INI-Param: SS7MTP3RdcyMode"
|
|
::= {acSS7Redundancy 2}
|
|
|
|
|
|
|
|
acSS7RedundancyBoardNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the board number for the SS7 (Signaling System 7) MTP3
|
|
redundancy mode. Each board is allocated a unique number.
|
|
All boards share a single redundancy table.
|
|
Access: Offline.
|
|
AC INI-Param: SS7MTP3RdcyBoardNum"
|
|
::= {acSS7Redundancy 3}
|
|
|
|
|
|
|
|
acSS7RedundancyCrossLinkTraceAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0)
|
|
,
|
|
enable(1)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"When set via INI-file, activates trace output for all X-links
|
|
(only when SS7 redundancy is configured).
|
|
.
|
|
Access: Instant.
|
|
AC INI-Param: SS7M3BRdcyXlinkTraceAll"
|
|
::= {acSS7Redundancy 4}
|
|
|
|
|
|
|
|
acSS7RedundancyMTP3RdcyTblSyncInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..144000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the interval between SS7 tables automatic synchronizations,
|
|
in minutes.
|
|
|
|
0 = no automatic synchronization is activated.
|
|
.
|
|
Access: Instant.
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Redundancy 5}
|
|
|
|
|
|
|
|
acSS7RedundancySyncAllBoards OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(0)
|
|
,
|
|
sync(1)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provide SYNC all boards command.
|
|
Access: Instant.
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Redundancy 6}
|
|
|
|
|
|
|
|
acSS7RedundancySyncBoard OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provide SYNC between this board and another specific board (parameter
|
|
is the remote board number).
|
|
Access: Instant.
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Redundancy 7}
|
|
|
|
|
|
|
|
acSS7RedundancyKeepAliveWindow OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines redundancy X-link keep-alive tolerance window.
|
|
(x-link between boards in Signaling System 7 (SS7) MTP3-User
|
|
Adaptation Layer redundancy mode).
|
|
.
|
|
Access: Offline.
|
|
AC INI-Param: SS7MTP3RdcyKeepAliveWindow"
|
|
::= {acSS7Redundancy 8}
|
|
|
|
|
|
|
|
acSS7RedundancyKeepAliveInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines redundancy X-link keep-alive interval in secs.
|
|
(x-link between boards in Signaling System 7 (SS7) MTP3-User
|
|
Adaptation Layer redundancy mode).
|
|
0 = no keep-alive mechanism is activated.
|
|
.
|
|
Access: Offline.
|
|
AC INI-Param: SS7MTP3RdcyKeepAliveInterval"
|
|
::= {acSS7Redundancy 9}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RedundantSN table declaration
|
|
-- ****************************************
|
|
acSS7RedundantSNTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcSS7RedundantSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {acSS7Redundancy 21}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RedundantSN table entry
|
|
-- ****************************************
|
|
acSS7RedundantSNEntry OBJECT-TYPE
|
|
SYNTAX AcSS7RedundantSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acSS7RedundantSNBoardIndex,acSS7RedundantSNIndex}
|
|
::= {acSS7RedundantSNTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acSS7RedundantSN TABLE
|
|
-- ****************************************
|
|
AcSS7RedundantSNEntry ::= SEQUENCE {
|
|
acSS7RedundantSNBoardIndex Unsigned32,
|
|
acSS7RedundantSNIndex Unsigned32,
|
|
acSS7RedundantSNRowStatus RowStatus,
|
|
acSS7RedundantSNAction Unsigned32,
|
|
acSS7RedundantSNActionRes Unsigned32,
|
|
acSS7RedundantSNBoardIp IpAddress,
|
|
acSS7RedundantSNOPC Unsigned32,
|
|
acSS7RedundantSNALCAPOPC Unsigned32
|
|
}
|
|
|
|
|
|
|
|
acSS7RedundantSNBoardIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First index for a line: board number.
|
|
AC INI-Param: SS7_RDCYSN_BOARD_INDEX"
|
|
::= {acSS7RedundantSNEntry 1}
|
|
|
|
|
|
|
|
acSS7RedundantSNIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second index for a line: SN number in the board.
|
|
AC INI-Param: SS7_RDCYSN_SN_INDEX"
|
|
::= {acSS7RedundantSNEntry 2}
|
|
|
|
|
|
|
|
acSS7RedundantSNRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROWSTATUS field for line.
|
|
AC INI-Param: SS7_RDCYSN_ROWSTATUS"
|
|
::= {acSS7RedundantSNEntry 3}
|
|
|
|
|
|
|
|
acSS7RedundantSNAction OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION.
|
|
AC INI-Param: SS7_RDCYSN_ACTION"
|
|
::= {acSS7RedundantSNEntry 4}
|
|
|
|
|
|
|
|
acSS7RedundantSNActionRes OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management field for ACTION RESULT.
|
|
AC INI-Param: SS7_RDCYSN_ACTIONRES"
|
|
::= {acSS7RedundantSNEntry 5}
|
|
|
|
|
|
|
|
acSS7RedundantSNBoardIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the board.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RDCYSN_BOARD_IP"
|
|
::= {acSS7RedundantSNEntry 6}
|
|
|
|
|
|
|
|
acSS7RedundantSNOPC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal point-code of the SN (Signaling Node).
|
|
Access: Online.
|
|
AC INI-Param: SS7_RDCYSN_OPC"
|
|
::= {acSS7RedundantSNEntry 7}
|
|
|
|
|
|
|
|
acSS7RedundantSNALCAPOPC OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal point-code of ALCAP instance on a given board.
|
|
Access: Online.
|
|
AC INI-Param: SS7_RDCYSN_ALCAP_OPC"
|
|
::= {acSS7RedundantSNEntry 8}
|
|
|
|
|
|
|
|
acSS7Status OBJECT IDENTIFIER ::= {acSS7 2}
|
|
|
|
|
|
acSS7Constants OBJECT IDENTIFIER ::= {acSS7Status 1}
|
|
|
|
|
|
acSS7ConstantsNumberOfNodes OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 1}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfLinks OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 2}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfLinkSetsPerSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 3}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfLinksPerLinkSet OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 4}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfRouteSetsPerSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 5}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfRoutesPerRouteSets OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 6}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfNodeTimerSets OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 7}
|
|
|
|
|
|
|
|
acSS7ConstantsNumberOfLinkSetTimerSets OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
AC INI-Param: N/A"
|
|
::= {acSS7Constants 8}
|
|
|
|
|
|
|
|
|
|
|
|
END
|